108-93018 05 APR 2016 Rev M



Similar documents
TECHNICAL SPECIFICATION

Communication, Signal & Data Cables

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

INTERNATIONAL STANDARD

AMP CO Plus Insert for Cat. 6 A Applications

Copper Cabling Infrastructure Offering

Specification SFTP CAT6 Network Cable 23AWG CU

E Series. E Series. Category 6 and 5e. Features

Copper Cables CONNECTIVITY & CABLING SYSTEM

Fire Resistant Cables

HARTING Ethernet Cabling 8-poles Overview

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)

Gulf Cable & Electrical Ind. Co.

INTERNATIONAL STANDARD

RADOX railway cables acc. to EN and EN Edition 2009

Accelerating Light. Copper Cabling Solutions. Category 6A

Fibre optic cables MDIC LSZH

Global cable expertise for rolling stock

SYSTIMAX Solutions. GigaSPEED X10D Shielded (F/UTP, S/FTP) Solution Guide Europe, Middle East and Africa Regions.

Fire Performance Standard

DATA SHEET SERVO LK SMS FX8PLUS SIGNAL

MICROCABLES. A complete vision of your connectivity needs. Catalogue

Standard Buccaneer - Ethernet

International Electrotechnical Commission Standards

Cables and Accessories Selection Guide

Requirements for Modular Patch Cords (e.g. RJ45 patch cords for Cat5 and Cat6 cabling systems)

PROFIBUS cable. for PROFIBUS-PA and -DP 10/ EN

with coloured cores and overall copper screen UL/CSA... 17

The Quality Connection. BETAflam Fire Resistant Safety Cables

HARTING Ethernet Cabling 4-poles Overview

Safety & Performance in the Wire and Cable Industry

Flexible and safe solutions, for decades. Cables for alarmand safety systems

FIRE RESISTANT CABLE CONSTRUCTION OF CABLES

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

HARTING Ethernet Cabling 4-poles Overview

FIBRA OPTICA INTERIOR/EXTERIOR TIGHT BUFFER

Category 6 Solutions. 4. Category 6 Solutions. 09/ IN TrueNet Structured Cabling. Introduction Cable Patch Panels... 4.

CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY

RF & Microwave cable assemblies C291

Fiber Optic Cordage. Interconnect A Furukawa Company. Product Description. Why OFS Interconnect Cordage?

EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.

12 Fibre MTP Jumper, MTP (non-pinned) to MTP (pinned)

WHITE PAPER Fire & safety performance standards

CABLE SPECIFICATION CAN CAB RJ45-SUBD9

Data Cables. European Edition

Bare copper complying with CEI EN (CEI 20-29) class 1. Foam PE with HDPE skin. Core colours: green and red

BUS 1010F Cavo per posa fissa (INTERBUS Remote Bus, 2-wire) INTERBUS cable for fixed installation

GOWN. Central Loose Tube Cables Outdoor, Steel Wire Armor (SWA) A-DQ(ZN)2YB2Y Full Rodent Protection. Ordering Information.

Type XHHW-2 or RHH/RHW-2/USE-2 GenFree II LSZH XLPO Single Conductor

Broadcast and Commercial AV Cabling MASTER CATALOG

RF cables. Edition 2015

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

Commercial Coaxial Cable

The most important matter is to select the right product based on the environment in which it will be installed and on its use or application.

D A T A C O M M U N I C A T I O N S C O M P E T E N C E C E N T E R

The Quality Connection. IT Cabling Systems

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

Cable Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell's Genesis Series provides a full range

3M Twisted Pair Flat Cable.050" 28 AWG Stranded, Mass Terminatable Pair, PVC 1700 Series

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

CAVEL VS80205 MADE IN ITALY 1000 V

FIBER-OPTIC CABLES LWL-KABEL

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

GOSB. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Standard Rodent Protection. Ordering Information. Applications. Features & Benefits

MICRO SFP+ CONNECTOR & CABLE ASSEMBLY

Encoders. the incremental encoders format such as relective optical technology, transmissive optical technology

Category 6 UTP - Cabling System

ETHERLINE Ethernet Cable, Connectors & Tools

LS Data Communication Product

3M High Flex Life Cable.050" 28 AWG Stranded, PVC 3319 Series

1394 locking cables. Your locking cables for AVT IEEE 1394 cameras

SECTION COMMUNICATIONS OPTICAL FIBER OSP CABLING

Panduit 28 AWG Patch Cords Installation Guideline

6000 Series Buccaneer

BETAtrans. Cables and Systems for Rolling Stock. Edition 2006

Building Cables and Wires

ELEVATOR CABLING SYSTEMS. Power and data for modern elevators. Cabling Solutions

SUBJECT: NO MORE 300 VOLTS IN PLTC PRINT LEGEND

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

ZS10 Screw Clamp Terminal Block

INDOOR PHONE INSTALLATION (CONCEALED) TECHNICAL SPECIFICATION

Two Position Cable-to-Board Power Connector System (Right Angle/Straight) with Coding Contacts

BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr /2009

CLEVELAND CABLE LOCATIONS

Tri-Rated Flexible PVC Equipment Wire

HGS620 Shielded Outlet Termination Instructions

Outside Telephone Cable

High-ohmic/high-voltage resistors

Uniprise Solutions COAX 101. White Paper.

HARTING Ethernet Cabling 4-poles Overview

Flexible Control Cables

Innovative Connectivity Solution for Maximum Performance and Security

COAX Cables Radio Frequency Cables

We specialize in low voltage cables including: Stranded Single Cable H07V-R Flexible Single Cable H05V-K

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Copper Pre-terminated Assemblies

Digital input modules

AWG: Cat5e: Cat6: Cat6A:

Transcription:

Product Specification 108-93018 05 APR 2016 Rev M Copper LAN Cable 1. SCOPE 1.1. Content This specification describes the general requirements for CommScope copper LAN cable. 2. APPLICABLE DOCUMENTS The following documents form a part of this specification to the extent specified herein. Unless otherwise specified, the latest edition of the document applies. In the event of conflict between the requirements of this specification and the drawing or any CommScope documents listed below, the drawing shall take precedence. In the event of conflict between the requirements of this specification and the referenced documents, this specification shall take precedence. 2.1. CommScope Documents A. Applicable Product Drawing B. EMS0092 Environmental Specifications for Enterprise Apparatus Products 2.2. Industrial Standards A. EN 50173-1 Information Technology; Generic Cabling Systems B. EN 50288 Multi-element metallic cables used in analogue and digital communication and control C. ISO/IEC 11801 Information technology Generic Cabling for Customer Premises D. IEC 60332 Tests on electric and optical fiber cables under fire conditions Test for vertical flame propagation for a single insulated wire or cable Test for vertical flame spread of vertically-mounted bunches wires or cables. E. IEC 60754-1 Test on gases evolved during combustion of electric cables Determination of the amount of halogen acid gas F. IEC 60754-2 Test of gases evolved during combustion of electric cables Determination of degree of acidity of gases evolved during the combustion of materials taken from electric cables by measuring ph and conductivity. G. IEC 61034 Measurement of smoke density of cables burning under defined conditions H. IEC 61156 Multicore and symmetrical pair/quad cables for digital communications. I. RAL No 840-HR Colour register J. UL 444 section 6.7 Communications cables Durability of printing K. ISO/IEC 14763-2 Information technology Implementation and operation of customer premises cabling Part 2: Planning and installation 3. REQUIREMENTS 3.1. Design and Construction The product shall be of design, construction and physical dimensions as specified on the applicable drawing. 2015 CommScope, Inc. All rights reserved 1 of 9

3.2. Materials Materials shall be as specified on the applicable drawing. Product and processing shall be in accordance with CommScope requirements for environmentalrelated substances as per EMS0092. Cable jacket material is identified on the cable drawing. This material shall comply to the standards as mentioned in underneath table: Jacket material Fire rating Toxicity Acid gas Smoke density PVC IEC 60332-1-2 - - - LSZH IEC 60332-1-2 IEC 60754-1 IEC 60754-2 IEC 61034-2 LSFRZH IEC 60332-3-24 IEC 60754-1 IEC 60754-2 IEC 61034-2 3.3. Ratings Installation temperature: 0 to 50 C Operating temperature: -20 to 60ºC 3.4. Transmission Performance Transmission performance shall be according to ISO/IEC 11801, EN 50173-1 and standards listed in the table underneath. Category (1) Construction (1) IEC requirement (2) (3) (6) (7) (8) (9) (2) (3) EN requirement SOLID CABLE 5 UTP ISO/IEC 11801 1 st Edition 1995 Cat5 - UTP EN 50288-3-1 5e F/UTP IEC 61156-5 Cat 5e SF/UTP EN 50288-2-1 UTP EN 50288-6-1 6 U/FTP IEC 61156-5 Cat 6 F/UTP EN 50288-5-1 F/FTP UTP EN 50288-11-1 6A F/UTP IEC 61156-5 Cat 6A F/FTP EN 50288-10-1 7 F/FTP S/FTP IEC 61156-5 Cat 7 EN 50288-4-1 7A S/FTP IEC 61156-5 Cat 7A EN 50288-9-1 1200MHz S/FTP 22AWG IEC 61156-7 - STRANDED CABLE UTP EN 50288-3-2 5e F/UTP IEC 61156-6 Cat 5e SF/UTP EN 50288-2-2 6 UTP IEC 61156-6 Cat 6 EN 50288-6-2 7 S/FTP IEC 61156-6 Cat 7 EN 50288-4-2 7A S/FTP IEC 61156-6 Cat 7A EN 50288-9-2 (5) 1200MHz S/FTP IEC 61156-6 Cat 7A (4) - Rev M 2 of 9

NOTE (1) Cable Category and construction are indicated in Product Drawing NAME NOTE (2) In the event of conflict between IEC and EN requirements, IEC requirements shall take preference. NOTE (3) For Characteristic/Input Impedance [ZO/Zin] and Mean ZO/Zin, see Annex included in this document. NOTE (4) 1200MHz S/FTP stranded cable is according to IEC 61156-6 Cat 7A requirements. Values in the frequency range from 1000MHz up to 1200MHz should be according to the proper formulae of mentioned standard (extrapolated up to 1200MHz). NOTE (5) This standard is in draft status at the moment of editing this document. Coupling attenuation parameter shall be according to requirements defined in IEC 61156-5 Ed.2.1 Dec 12 (solid cable) and IEC 61156-6 Ed.3.1 Dec 12 (stranded cable) according following table: NOTE (6) Cable Construction/ Category Cat 5e Cat 6 Cat 6A Cat 7 Cat 7A 1200 UTP --- --- --- --- --- --- U/FTP Type II Type II Type Ib --- --- --- F/UTP Type II Type II Type Ib --- --- --- SF/UTP Type II Type II Type Ib --- --- --- F/FTP --- --- Type Ib Type I --- --- S/FTP --- --- Type Ib Type I Type I Type I (*) Type I requirements 30 to 100MHz: >85dB Type Ib requirements 30 to 100MHz: >70dB Type II requirements 30 to 100MHz: >55dB (*) For solid cables, according to requirements defined in IEC 61156-7 Ed1.1 Dec 12. For stranded cables, according to requirements defined in IEC 61156-6 Ed.3.1 Dec 12, extrapolated up to 1200MHz. The absorbing clamp method, as defined in IEC 62153-4-5, is the preferred test methodology for coupling attenuation parameter. Rev M 3 of 9

Transfer impedance parameter shall be according to requirements defined in IEC 61156-5 Ed.2.1 Dec 12 (solid cable) and IEC 61156-6 Ed.3.1 Dec 12 (stranded cable) according following table: NOTE (7) Cable Construction/ Category Cat 5e Cat 6 Cat 6A Cat 7 Cat 7A 1200 UTP --- --- --- --- --- --- U/FTP Grade II Grade II Grade II --- --- --- F/UTP Grade II Grade II Grade II --- --- --- SF/UTP Grade II Grade II Grade II --- --- --- F/FTP --- --- Grade II Grade II --- --- S/FTP --- --- Grade I Grade I Grade I Grade I (*) (*) For solid cables, according to requirements defined in IEC 61156-7 Ed1.1 Dec 12. For stranded cables, according to requirements defined in IEC 61156-6 Ed.3.1 Dec 12. The Short-Short without damping resistor method (test method C), as defined in IEC 62153-4-3, is the preferred test methodology for transfer impedance parameter. Test method defined at EN 50289-01-06 can be used as alternative method. TCL parameter shall be according to requirements defined in IEC 61156-5 Ed.2.1 Dec 12 (solid cable) and IEC 61156-6 Ed.3.1 Dec 12 (stranded cable) according following table: NOTE (8) Cable Construction/ Category Cat 5e Cat 6 Cat 6A Cat 7 Cat 7A 1200 UTP Level II Level II Level II --- --- --- U/FTP Level II Level II Level II --- --- --- F/UTP Level II Level II Level II --- --- --- SF/UTP Level II Level II Level II --- --- --- F/FTP --- --- Level I Level I --- --- S/FTP --- --- Level I Level I Level I Level I (*) (*) For solid cables, according to requirements defined in IEC 61156-7 Ed.1.1 Dec 12. For stranded cables, according to requirements defined in IEC 61156-6 Ed.3.1 Dec 12. Rev M 4 of 9

Segregation Class, according to IEC 14763-2 is defined according following table: Cable Construction/ Category Cat 5e Cat 6 Cat 6A Cat 7 Cat 7A 1200 UTP b/c/d (3) b/c/d (3) b/c/d (3) b/c/d (3) b/c/d (3) b/c/d (3) U/FTP c (2) c (2) c (2) --- --- --- F/UTP c (2) c (2) c (2) --- --- --- SF/UTP c (2) c (2) c (2) --- --- --- F/FTP --- --- c (2) d (1) --- --- S/FTP --- --- c (2) d (1) d (1) d (1) NOTE (9) (1) Cables meeting the Type I coupling attenuation requirements of IEC 61156-5 and IEC 61156-6 meet segregation Class d. (2) Cables meeting the Type II coupling attenuation requirements of IEC 61156-5 and IEC 61156-6 meet segregation Class c. (3) Cables meeting the Level 2 TCL requirements of IEC 61156-5 and IEC 61156-6 meet segregation Class b. These cables may deliver performance of segregation Class c or d provided that the following requirements are also met, according to IEC 14763-2: - Class c : TCL at (30 to 100MHz) 60-10 log10(freq) - Class d : TCL at (30 to 100MHz) 70-10 log10(freq) Minimum separation, according to IEC 14763-2 is defined according following table: Segregation Class Free space separation (mm) Containment applied to information technology or mains power cabling Perforated Open metallic Solid metallic metallic containment containment (mm) (1) containment (mm) (mm) d 10 8 5 0 c 50 38 25 0 b 100 75 50 0 a 300 225 150 0 (1) The upper surface of installed cables shall be at least 10 mm below the top of the barrier Rev M 5 of 9

3.5. Physical & Esthetical Characteristics A. Stripability of the jacket: max. 80N to strip 50 mm of the jacket. B. Min. bending radius of the cable during installation: 8 x outer diameter C. Min. bending radius of the cable after installation: 4 x outer diameter D. Insulation colours shall be blue, orange, green, brown and white in accordance with IEC 60304. Coloured trace on white wires is optional. Pair 1 Pair 2 Pair 3 Pair 4 White and Blue White and Orange White and Green White and Brown E. Jacket colour shall be in accordance with RAL Colour register No 840-HR: Cable colour RAL Cable colour RAL Black 9011 Blue 5012 White 9003 Violet 4005 Brown 8016 Red 3000 Grey 7035 Orange 2003 Green 6018 Yellow 1021 Rev M 6 of 9

3.6. Cable Print Legend COMMSCOPE ISO-EN COMPLIANT XXXXXX <basenr specific info> YYWW Z (SEQUENTIAL No) METER A. XXXXXX is CommScope s manufacturing location. B. <basenr specific info> is described on the drawing of the relevant base number. C. YYWW is date code: YY - Year, WW Week i.e.: 1321 = year 2013, week 21 (per specification 102-60) D. Z is manufacturing batch #. E. Sequential meter marking every meter. Sequential meter is not returned to zero for each length. Sequential meter accuracy to be ±1%. F. Print legend shall be in capital characters, font Courier, font style Regular, character height: 2,5 mm for cable Ø < 5,5 mm 3,0 mm for cable Ø 5,5 mm G. Print colour shall be white or yellow for black or brown jackets and shall be black for all other jacket colours. H. Print durability shall be per UL 444 section 6.7. 3.7. Packaging Length Tolerance Tolerance applicable for different length should be as follow: Length [meter] Tolerance 305 0 + 6% 500 0 + 4% 1000 0 + 2% For any other non-specified length, the tolerance of the immediately lower length should be applied, for instance in case of 600 m, then 0 + 4% shall be applied. 3.8. Packaging and Labeling Product should be delivered according to specified in drawing. 4. PRODUCT QUALIFICATION AND RE-QUALIFICATION TEST SEQUENCE Quality provisions are based upon the philosophy of TQM (Total Quality Management) with a system approved to EN ISO 9001 by Lloyds Register Quality Assurance. 4.1. Responsibility for Quality Unless otherwise stated in the customer order, it shall be CommScope s responsibility to assure qualification and lot conformance to this specification. CommScope may utilize its own or other testing and inspection facilities acceptable to the customer. 4.2. Qualification Conformance & Re-qualification Test Sequence For the purposes of internal qualification, the program shall consist of: Rev M 7 of 9

A. Sample Selection For each cable type, 3 samples of 110m of different date code shall be provided for qualification purpose. These samples shall comply with the requirements defined on the drawing and in this specification. Deviations in the cable jacket color and the cable print legend are accepted for qualification samples. Third party certificate can be accepted from an independent laboratory recognized by CommScope. B. Re-qualification Testing If changes - significantly affecting form, fit or function - are made to the product or manufacturing process, re-qualification testing shall be initiated, consisting of all or part of the original testing sequence as determined by CommScope. 5. REVISION SUMMARY This paragraph is reserved for a revision summary of changes and additions made to this specification. Updated format and Company name. Rev M 8 of 9

ANNEX: Characteristic/Input Impedance [Zo/Zin] and Mean Zo/Zin considerations Characteristic/ Input Impedance (1) Test Parameter Mean Characteristic/ Input Impedance Test Requirement Solid cable Stranded cable Available limits from IEC 61156-5 Ed.2.1 Dec 12 Available limits from IEC 61156-6 Ed.3.1 Dec 12 100Ω ± 5 % @ 100MHz per IEC 61156-5 Ed.2.1 Dec 12 100Ω ± 5 % @ 100MHz Additional comments Upper and lower limits from IEC 61156-5 Ed. 1.0 Mar 02 and IEC 61156-6 Ed. 1.0 Mar 02 are considered ONLY for information. -- NOTE (1) Due to test method followed by CommScope, obtained parameter is Input impedance instead of Characteristic impedance. In any case, the same requirement is applicable for both. Rev M 9 of 9