2 Belden Data Cables Reliable Performance through Innovation Table of Contents Reliable Performance through Innovation Belden Quality Cable Finder Unshielded cables UTP Category 5E UTP Category Shielded cables (S)FTP Category 5E (S)FTP Category ISTP Category 7 Ordering Information & DataTwist Colour Code Table Page Reliability, performance Over the years, Belden has become an international byword for premium quality and reliability, an accolade for excellence earned through decades of dedication to meeting the highest industry standards. Our strategic objective is to provide our customers with superior solutions for their present and future wire and cable needs. Accordingly, every solution we devise is based on performance, innovation and reliability the three cornerstones of Belden s business strategy. A long history of innovation For the past years, Belden has been an acknowledged front-runner in the wire and cable industry, developing novel technologies and processes for the manufacture of innovative wire and cable products. Products that keep our customers at the forefront of new developments in their chosen field. Starting in 1902, when the company was founded in Chicago, Belden has consistently pioneered breakthrough technologies and set new industry standards. This trend was set with early successes like Beldenamel insulation (1905) and the introduction of the soft rubber plug in 19. Ever since, Belden has been an industry innovator, conceiving and developing special applications in cabling, shielding and jacketing. All focused on customer needs. All clearly establishing Belden s leadership in wire and cable technology. Belden s commitment to innovation has historically fuelled new growth for industry players. It has also earned Belden global innovation leadership that is constantly driven by the Belden Engineering Centres. For instance with Duobond, Flamarrest, French Braid, MediaTwist and DataTwist 0e. Another yardstick for measuring the success of our novel products are the many patents we hold. But the ultimate criterion is the fitness for use of the products we supply to our customers. Global player The company s successful growth strategy in the 1990s led in 1999 to the purchase of Cable Systems International, the largest specialty telecom cable facility in the world. Other capabilities were created by acquisitions in Hungary, United Kingdom, the USA and the Netherlands, where Belden has its European headquarters and a large R&D Centre and manufacturing facility. Apart from Europe and the US, Belden s worldwide presence includes marketing and sales organizations in Asia Pacific, Latin America and the Middle East. Today, Belden is a global player in the wire and cable industry, designing, manufacturing and marketing specialty cable, such as copper, and optical fibre cable for electrical, electronic and communications equipment. Reliable products that help Belden s customers keep pace with the shifting dynamics of these fast-moving markets. 1
3 Reliable Performance through Innovation European manufacturing operations As Belden s global business plans call for a commitment to local markets world-wide and a thorough understanding of local dynamics, Belden has established a very significant presence in core European markets. This ensures that appropriate solutions can always be found to meet the cable and wire needs of our European customers. NYNÄSHAMN MOSCOW Belden has the largest range of cable products in all the markets we serve. Dedicated products matched to local needs. These include over.000 products for computer networking and computer equipment; for telecommunications and industrial instrumentation and control; for broadcasting and entertainment; and for cable television and electrical equipment. MANCHESTER VENLO With European sales accounting for almost a quarter of Belden s world-wide turnover, Belden has clearly demonstrated the success of its Think global, act local approach. And with its 0-strong workforce across Europe and sales offices from Moscow to Lyon and from Stockholm to Dubai Belden has a strong local capability to understand customers problems and to provide the answer. LYON VILLINGEN- SCHWENNINGEN MILANO BUDAPEST Belden s European headquarters and manufacturing base is in the Netherlands, where the company also has its European Engineering Centre. Detailed brochures Full-colour brochures are available on the extensive range of Belden products: Digital telephony cables Shielded and non-shielded cables Multi-conductor cables Optical fibre cables Audio/ video cables Coaxial broadband cables Electrical cables To request detailed brochures and datasheets on our product lines and the extensive Belden Master Catalog, please contact your local Belden representative or send an to [email protected] Manufacturing Facilities Addressing environmental issues correctly is recognized as a high priority, particularly in the industrialized world and not least at Belden. Accordingly, the company makes every effort to minimize the environmental impact of its operations and products. Recognizing ecological concerns shared by customers and consumers world-wide, from a working group at Belden s European headquarters in Venlo completed Distribution Centers Sales Offices ISO 1 EMS Environmental Management System comprehensive preparations for ISO 1 EMS certification. This environmental management and audit system was implemented and certified in 1. The progress achieved in the practical implementation of Belden s environmental objectives will be published each year. This will include the measures taken by the company to minimize the environmental impact of Belden s operations, also in respect of (energy) savings in production and novel materials and processes. USA United Kingdom The Netherlands Table of Contents 2
4 Belden Data Cables Belden Quality The Belden approach to cable quality Belden s commitment to quality begins even before its products leave the product development phase. Not only does Belden design products to achieve a given level of performance, it also ensures that these products can be manufactured in a way that makes that performance possible and consistent. The keyword in the Belden approach is prevention. Prevention involves the use of key parameters of product performance and statistical methods to monitor the process and identify changes that affect the quality of the product and adjust the process accordingly. The responsibility for quality moves from the inspectors to the design and manufacturing departments. Product quality at Belden begins long before we ever manufacture a single meter of cable. Here s a look at how we do it: Design for manufacturability Delivering a superior product means being sure you make a superior product, day after day. Design for Manufacturability (DFM) seeks to identify and account for the challenges inherent in any manufacturing process and address them up front. It takes into account every aspect of manufacturing: materials, machines, operations, environmental factors, and more. The purpose of DFM is to design products that are robust enough to stand up to the challenges of manufacturing to yield consistent, superior product quality. DFM is focused on the entire manufacturing process and how it can be monitored, controlled, and adjusted to achieve our quality goals. The benefit to Belden customers is that our products achieve high performance standards that are both consistent and measurable. Monitoring & maintaining quality Before releasing any new products for production, all critical characteristics, such as dimensions, electricals, and physicals are targeted to meet a capability index (Cpk) 1., which corresponds to a % passing rate. A Cpk is an index that quantifies the capability of a product s design and manufacturing process. It takes the actual performance of a product and compares it to a benchmark level of performance (e.g.: the industry standard). Cpk = Headroom (average worst case margin from spec.) 3 x Standard deviation The Cpk values are determined through capability studies, which represent the final product design and manufacturing set-ups. This includes statistically valid run times, sampling quantities and methods. The result is a Cpk value that corresponds to a predicted defect rate for the product. Based on these statistics ( measuring % is simply not possible) % of the Belden products will pass the applicable cable standards. If Belden specifies headroom above a cable standard this will always means in addition to the Cpk = 1. range (4 ). Variation of a product characteristics that performs just within our specification. Lower Spec. 4 3 = 1.0 Avg: 4.0 db % of Product 3 = 1.0 Cpk % of Product 4 = 1. Cpk = Design Goal db 7.0 db Test lab Belden Engineering Centre Belden s Cpk testing methods are actually more reliable than simple pass/ fail testing on cable as it comes off the manufacturing line. Rather than merely testing batches of cable, Cpk testing allows Belden to monitor and control the long-term quality and performance of the cable we produce. Cpk s are tracked constantly through Plant Quality Assurance, using in-house developed Quality Data Acquisition Systems. The generated Cpk values give us an accurate measurement of quality over time, and are used to drive continuous quality improvements. It enables us to adjust our manufacturing processes in ways that ensure the production of high performance cable, day in day out. 3 Table of Contents
5 Belden Quality Bonded pairs Installed performance is the performance of a channel in real world installation conditions. Common real world conditions include the use of cable that have experienced severe flexing when pulled around bends and corners and cable coiled into service loops and/ or stuffed into outlet boxes. The Belden Bonded Pair cables provide better installable performance, due to its unique, patented design. Better by design For a twisted pair cable, a solid design begins with the individual conductors and their relationship to one another forming a pair. An ideal pair is comprised of two perfectly balanced insulated conductors that are mirror images of each other. The copper used in the two conductors is identical with exactly the same dimensions and is also perfectly centered, or concentric, within each insulated conductor. The ideal twisted pair, with perfect centricity and concentricity. Design dictates performance Belden Bonded Pair cables are designed to maintain their outstanding performance after installation. To demonstrate this, an Installation Stress Test has been designed and implemented. To simulate pulling the cable through and around cable trays, ceilings and walls, each cable was run through a series of controlled bends and twists. Next, the end of the cable was placed into an outlet box, and a 3 meter length of the cable was loosely coiled into a service loop at the workstations end. The cables were tested before and after the test to identify any changes in performance. If we compare the RL values of the Cat5E Belden Bonded Pair cable vs. an industry leading Cat5E cable we find that the Unbonded Pair cable s RL value degraded by more than db, or more than 15 times their before-installation values. Belden s Bonded Pair cables exhibited little change in RL performance. (For more detailed information, please refer to Belden Technical Bulletin TB-, The Impact of Typical Installation Stresses on cable Performance.) Industry 0 MHz Cat 5e Cable Return Loss Margins ( MHz) Centricity Margin (db) Higher is better Spec. Limit Fail Initial Installed Centricity Belden DataTwist 0 Cat 5e Return Loss Margins ( MHz) To maintain this perfect balance, the center-to-center distance, or centricity, between the copper conductors must remain fixed and should never vary not even in the slightest! In balanced signal transmission on an ideal pair, these concentricity and centricity factors help ensure that the signal does not radiate or bleed off the pair and that the pair cancels out all incoming noise. When the conductors of a twisted pair become separated, impedance mismatches, Return Loss (RL), and crosstalk problems arise. In order to prevent this separation from occurring and to provide structural stability, Belden has developed its patented Bonded Pair technology. As the picture illustrates, even when a Bonded Pair cable is bent, its conductor-to-conductor spacing remains stable. Margin (db) Initial Installed Data Pairs Blue Orange Green Brown Higher is better Spec. Limit Only a Bonded Pair will not gap when the pair is bent around a corner. Unbonded Pair Bonded Pair Performance reduces costs To further document the after-installation performance of both Bonded Pair and Unbonded Pair cables, Belden surveyed a large number of contractors regarding their installation experiences. This survey showed a clear difference between the two cable types after installation was complete and field testing was conducted to verify compliance with industry standards, both proposed Category and Category 5E. It showed that the Belden Bonded Pair cables cause significantly less test failures compared to Unbonded Pair cables. In fact, with Bonded Pair cables time savings of up to 1.5 minutes per drop (Cat 5E) and 2.5 minutes per drop (Cat ) can be expected because far less troubleshooting and re-work is required. (For more detailed information, please refer to Belden Technical Bulletin TB-7, Contractor Field-Testing Survey Reveals Performance- Related Cost savings Using Bonded Pair Cables.) Table of Contents 4
6 Belden Data Cables Cable Finder Origin Industry standards Belden part number US product Europe product Description Tested to frequency (MHz) Remarks EN 1-1 TIA/EIA -B2 ISO/IEC 01 2nd ed. Page Unshielded Cables UTP Category 5E E ENH 17E 17ENH A ANH E ENH 1592A 1592ANH 17A 17ANH Twin E Twin ENH DataTwist 0 DataTwist 0 Twin E Twin ENH DataTwist Patch DataTwist Patch DataTwist 0 Patch DataTwist 0 Patch ,,, UTP Category 79E 79ENH E ENH 1A 1ANH 1GB A NH MediaTwist MediaTwist MediaTwist Patch DataTwist 0e DataTwist 0e ,,, Shielded Cables (S)FTP Category 5E 1E 1ENH 1E 1ENH A ANH 1E+ 1ENH+ 1E+ 1ENH+ 1E 1ENH Twin 1E Twin 1ENH Braided 1E Braided 1ENH Twin 1E+ Twin 1ENH+ Patch Patch, (S)FTP Category E ENH E+ ENH+ Braided E Braided ENH ,, ISTP Category 7 15ENH 17ENH Twin 15ENH 0 0 Notes: Plenum versions and various multipair cables available upon request. Please check for available outdoor cables. All specification limits according to ISO/IEC 01 2nd. Edition (September 2), unless otherwise stated. All values at frequencies below 4 MHz in this brochure are for reference only, in accordance with ISO/IEC 01. Typical values represent values from multiple tests of our products. These numbers are not guaranteed but are designed to give the user an idea of the products capabilities. The minimum/maximum values are guaranteed values. For ordering information see page. 5 Table of Contents
7 UTP Category 5E Belden E Belden ENH Belden 17E Belden 17ENH Halogen-free version Twin version of E Twin version of ENH Cat. 5E Product description Unshielded Twisted Pair Cable, 4 pairs x AWG. Solid bare copper conductors, polyolefine insulation. Colour code: see DataTwist colour code table on page. Applicable industry standards: EN 1, ISO / IEC 01, TIA / EIA - B2 Attenuation (db/ m) NET (db) PS-NET (db) PS-ELFET (db) ACR (db/ m) PS-ACR (db/ m) max. (Cat. 5E) Typical velocity of propagation (%): Max. DCR (Ohm/km): 94 Nominal capacitance (pf/m): Diameter of insulated conductor (mm): 0.90 Nominal overall diameter (mm): 5.0 Impedance (Ohm): Ohm ± 15 % Single Twin E 2 ENH 0 1 U 0 ft. U 5 m.5 kg 0 ft. 5 m.5 kg 1 ft. 0 m.0 kg 0 ft. 0 m 2.0 kg Belden A DataTwist 0 Bonded pairs Cat. 5E Belden ANH Belden A Belden ANH Halogen-free version Twin version of A Twin version of ANH Product description Unshielded Twisted Pair Cable, 4 x AWG, ripcord. Solid bare copper conductors, polyolefine insulation. Colour code: see DataTwist colour code table on page. Applicable industry standards: EN 1, ISO / IEC 01, TIA / EIA -B2 Flame test: UL CM UL ISDI Vertical Tray, CSA FT1 Attenuation (db/ m) NET (db) PS-NET (db) PS-ELFET (db) ACR (db/ m) PS-ACR (db/ m) max. (Cat. 5E) Typical velocity of propagation (%): Max. DCR (Ohm/km): 94 Nominal capacitance (pf/m): Diameter of insulated conductor (mm): 0.95 Nominal overall diameter (mm): 5.0 Impedance (Ohm): Ohm ± 15 % Single Twin A 5 0 ANH 59 U 0 ft. U 5 m.5 kg 0 ft. 5 m.5 kg 1 ft. 0 m.0 kg 0 ft. 0 m 2.0 kg Table of Contents
8 Belden Data Cables UTP Category 5E Belden 1592 A DataTwist Patch Cat. 5E Belden 1592 ANH Halogen-free version Product description Unshielded Twisted Pair Cable, 4 pairs x AWG. Stranded bare copper conductors, polyolefine insulated singles, PVC jacket. Colour code: see DataTwist colour code table on page. Applicable industry standards: TIA / EIA -B2, ISO / IEC 01 Flame test: UL CM UL Vertical Tray, CSA FT1 Attenuation (db/ m) PS-NET (db) PS-ELFET (db) PS-ACR (db/ m) guaranteed max. guaranteed guaranteed guaranteed guaranteed, Red, Green, Yellow, Orange, Violet, White, Black Velocity of propagation (%): 9 Typ. DCR (Ohm/ m): 7.9 Nominal capacitance (pf/ft.): 15 Diameter of insulated conductor (mm): Nominal overall diameter (mm):.0 Impedance (Ohm): 1 MHz: ± 15 % 2 MHz: ± % U 0 ft. U 5 m 9.5 kg 0 ft. 5 m 9.5 kg Belden 17 A DataTwist 0 Bonded pairs Patch Cat. 5E Belden 17 ANH Halogen-free version Product description Unshielded Twisted Pair Cable, 4 pairs x AWG. Stranded tinned copper conductors, polyolefine insulated singles with, PVC jacket. Colour code: see DataTwist colour code table on page. Applicable industry standards: TIA / EIA -B2, ISO / IEC 01 Flame test: UL CM UL Vertical Tray, CSA FT1 Attenuation (db/ m) PS-NET (db) PS-ELFET (db) PS-ACR (db/ m) guaranteed max. guaranteed guaranteed guaranteed guaranteed, Red, Green, Yellow, Orange, Violet, White, Black Velocity of propagation (%): Typ. DCR (Ohm/ m):. Nominal capacitance (pf/ft.): 15 Diameter of insulated conductor (mm): Nominal overall diameter (mm):.0 Impedance (Ohm): 1 MHz: ± 15 % 2 MHz: ± % * * U 0 ft. U 5 m.3 kg 0 ft. 5 m.3 kg * values at 0 MHz 7 Table of Contents
9 UTP Category Belden 79E Cat. Belden 79ENH Halogen-free version Product description Unshielded Twisted Pair Cable, 4 pairs x AWG. Solid bare copper conductors, polyolefine insulation, spline. Colour code: see DataTwist colour code table on page. Applicable industry standards: EN 1, ISO / IEC 01, TIA / EIA -B2 Attenuation (db/ m) NET (db) PS-NET (db) PS-ELFET (db) ACR (db/ m) PS-ACR (db/ m) max. (Cat. ) Typical velocity of propagation (%): Max. DCR (Ohm/km): Nominal capacitance (pf/m): Diameter of insulated conductor (mm): 1.01 Nominal overall diameter (mm):.2 Impedance (Ohm): 1 MHz: ± 15 % 2 MHz: ± % Single E 0 ENH 1 ft. 0 m kg 0 ft. 0 m.0 kg Belden E Bonded pairs Cat. Belden ENH Halogen-free version Product description Unshielded Twisted Pair Cable, 4 x AWG. Solid bare copper conductors, polyolefine insulation, spline. Colour code: see DataTwist colour code table on page. Applicable industry standards: EN 1, ISO / IEC 01, TIA / EIA -B2 Attenuation (db/ m) NET (db) PS-NET (db) PS-ELFET (db) ACR (db/ m) PS-ACR (db/ m) max. (Cat. ) Typical velocity of propagation (%): Max. DCR (Ohm/km): Nominal capacitance (pf/m): Diameter of insulated conductor (mm): 1.05 Nominal overall diameter (mm):.5 Impedance (Ohm): 1 MHz: ± 15 % 2 MHz: ± % Single E 5 ENH 5 U 0 ft. U 5 m.1 kg 1 ft. 0 m kg 0 ft. 0 m.0 kg Table of Contents
10 Belden Data Cables UTP Category Belden 1 A MediaTwist Bonded pairs Cat. Belden 1 ANH Halogen-free version Product description Unshielded Twisted Pair Cable, 4 pairs x AWG. Solid bare copper conductors, polyolefine insulated singles with, ripcord, PVC jacket. Colour code: see DataTwist colour code table on page. Applicable industry standards: TIA / EIA -B2, ISO / IEC 01 Flame test: UL type CMR, CMG, CM, UL 1 riser, UL Vertical Tray, CSA FT4 Attenuation (db/ m) PS-NET (db) PS-ELFET (db) PS-ACR (db/ m) max. (TIA /EIA Cat. ) Standard colour: Grey, Gold, Brown, Blue, Red, Green, Yellow, Orange, Violet Velocity of propagation (%): Typ. DCR (Ohm/ m): 7.4 Nominal capacitance (pf/ft.): 15 Diameter of insulated conductor (mm): Nominal overall diameter (mm):.0 Impedance (Ohm): 1 MHz: ± % MHz: ± 15 % 0 MHz: ± % 0 0 MHz: ± % ft. m 4.3 kg A 0 ft. A 5 m.2 kg Belden 1GB MediaTwist Bonded pairs Patch Cat. Belden 1GBNH Halogen-free version Product description Unshielded Twisted Pair Cable, 4 pairs x AWG. Stranded tinned copper conductors, polyolefine insulated singles with, PVC jacket. Colour code: see DataTwist colour code table on page. Applicable industry standards: TIA / EIA -B2, ISO / IEC 01 Flame test: UL CM UL Vertical Tray, CSA FT4 Attenuation (db/ m) PS-NET (db) PS-ELFET (db) PS-ACR (db/ m) guaranteed max. guaranteed guaranteed guaranteed guaranteed, Red, Green, Yellow, Violet, White, Black Velocity of propagation (%): Typ. DCR (Ohm/ m):.2 Nominal capacitance (pf/ft.): 15 Diameter of insulated conductor (mm): Nominal overall diameter (mm):.0 Impedance (Ohm): 1 MHz: ± % MHz: ± 15 % 2 MHz: ± % 2 0 MHz: ± % ft. 5 m.2 kg A 0 ft. A 5 m.2 kg 9 Table of Contents
11 UTP Category Belden A DataTwist 0e Bonded pairs Cat. Belden NH Halogen-free version Product description Unshielded Twisted Pair Cable, 4 pairs x AWG. Solid bare copper conductors, polyolefine insulated singles with, e-spline, ripcord, PVC jacket. Applicable industry standards: TIA / EIA -B2 Flame test: UL type CMR, UL1 riser listed, CSA FT4 Attenuation (db/ m) PS-NET (db) PS-ELFET (db) PS-ACR (db/ m) max. (TIA /EIA Cat. ) guaranteed max. guaranteed guaranteed guaranteed guaranteed, White Velocity of propagation (%): 7 Max. DCR (Ohm/ m):.2 Nominal capacitance (pf/ft.): 15.5 Diameter of insulated conductor (mm): Nominal overall diameter (mm):.0 Impedance (Ohm): 1 MHz: ± % 2 MHz: ± 15 % 2 0 MHz: ± % 0 0 MHz: ± % ft. 5 m.2 kg U 0 ft. U 5 m.2 kg A 0 ft. A 5 m.2 kg Colour code: Pair no. 1 Pair no. 2 Pair no. 3 Pair no White/Green & Green White/Orange & Orange White/Blue & Blue White/Brown & Brown The DataTwist 0e cable is a revolutionary UTP cable engineered specifically to perform well beyond proposed Category standards. While proposed Category cable is specified only to 2 MHz, DataTwist 0e is the only UTP cable in the industry fully characterized with guaranteed performance to 0 MHz. So users have far more headroom to compensate for unforeseen factors that can inhibit the performance of a cabling system today... and protection of their technology investment for the future. The Cable Preparation Tool is packed with every spool of Belden DataTwist 0e data cable. The Belden Cable Preparation Tool (1797B) now makes it faster and easier than ever to prepare cables for connector termination. This tool is ideal for use with Belden s Bonded Pair cables, providing special features that help separate twisted pairs. It can also be used to prepare any unbonded pair cable for installation. Pair Separation Techniques: Belden s Cable Preparation Tool features both the new Pick technique and the traditional Blade Slot technique to better facilitate pair untwisting. The Pick technique utilizes a steel awl that is incorporated into the tip of the tool that is surrounded on both sides with guards to assist in pair alignment during the pair separation step. The Pick technique allows for a simple pick-n-pull motion to easily separate the conductors of a twisted pair cable. The Blade Slot Technique provides the technician an alternate method for separating the conductors quickly and easily. See TB177 for detailed instructions for either technique. Table of Contents
12 Belden Data Cables (S)FTP Category 5E Belden 1E Belden 1ENH Belden 1E Belden 1ENH Halogen-free version Twin version of 1E Twin version of 1ENH Cat. 5E Product description Shielded Twisted Pair Cable, 4 pairs x AWG. Solid bare copper conductors, polyolefine insulation, overall foil shield, tinned copper drain wire. Colour code: see DataTwist colour code table on page. Applicable industry standards: EN 1, ISO / IEC 01 Attenuation (db/ m) NET (db) PS-NET (db) PS-ELFET (db) ACR (db/ m) PS-ACR (db/ m) max. (Cat. 5E) Typical velocity of propagation (%): Max. DCR (Ohm/km): 94 Nominal capacitance (pf/m): Diameter of insulated conductor (mm): 1.05 Nominal overall diameter (mm):.0 Impedance (Ohm): Ohm ± 15 % Single Twin E 4 9 ENH ft. 5 m.0 kg 1 ft. 0 m kg 0 ft. 0 m.0 kg Belden A Bonded pairs Cat. 5E Belden ANH Halogen-free version Product description Shielded Twisted Pair Cable, 4 x AWG. Solid bare copper conductors, polyolefine insulation, lateral foil shield, spiral tinned copper drain wire, Nylon ripcord, PVC jacket. Colour code: see DataTwist colour code table on page. Applicable industry standards: ISO / IEC 01 Attenuation (db/ m) NET (db) PS-ELFET (db) ACR (db/ m) max. (Cat. 5E) Typical velocity of propagation (%): Max. DCR (Ohm/km): 2 Nominal capacitance (pf/m): Diameter of insulated conductor (mm): Nominal overall diameter (mm):.7 Impedance (Ohm): Ohm ± 15 % U 0 ft. U 5 m.3 kg 0 ft. 5 m 1.2 kg 0 ft. 0 m.2 kg Table of Contents
13 (S)FTP Category 5E Belden 1E+ Braided Cat. 5E Belden 1ENH+ Halogen-free version Belden 1E+ Twin version of 1E+ Belden 1ENH+ Twin version of 1ENH+ Product description Shielded Twisted Pair Cable. 4 pairs x AWG. Solid bare copper conductors, polyolefine insulation, overall foil shield, tinned copper drain wire and tinned copper braid. Colour code: see DataTwist colour code table on page. Applicable industry standards: EN 1, ISO / IEC 01 Attenuation (db/ m) NET (db) PS-NET (db) PS-ELFET (db) ACR (db/ m) PS-ACR (db/ m) max. (Cat. 5E) Typical velocity of propagation (%): Max. DCR (Ohm/km): 94 Nominal capacitance (pf/m): Diameter of insulated conductor (mm): 1.05 Nominal overall diameter (mm):.3 Impedance (Ohm): Ohm ± 15 % Single Twin E 5 ENH 5 0 ft. 5 m. kg 1 ft. 0 m.0 kg 0 ft. 0 m.0 kg Belden 1E Patch Cat. 5E Belden 1ENH Halogen-free version Product description Shielded Twisted Pair Cable, 4 pairs x AWG 2. Stranded bare copper conductors, polyolefine insulation, overall foil shield, tinned copper drain. Colour code: see DataTwist colour code table on page. Applicable industry standards: EN 1, ISO / IEC 01 Attenuation (db/ m) NET (db) PS-NET (db) PS-ELFET (db) ACR (db/ m) PS-ACR (db/ m) max. (Cat. 5E) , Red, Green, Yellow Typical velocity of propagation (%): Max. DCR (Ohm/km): 1 Nominal capacitance (pf/m): Diameter of insulated conductor (mm): 0.95 Nominal overall diameter (mm): 5.2 Impedance (Ohm): Ohm ± 15 % Single E 0 ENH 5 Table of Contents 0 ft. 5 m.3 kg 1 ft. 0 m.5 kg 0 ft. 0 m.0 kg
14 Belden Data Cables (S)FTP Category Belden E Bonded pairs Cat. Belden ENH Halogen-free version Product description Shielded Twisted Pair Cable, 4 x AWG. Solid bare copper conductors, polyolefine insulation, overall foil shield and tinned copper drain wire. Colour code: see DataTwist colour code table on page. Applicable industry standards: EN 1, ISO / IEC 01 Attenuation (db/ m) NET (db) PS-NET (db) PS-ELFET (db) ACR (db/ m) PS-ACR (db/ m) max. (Cat. ) Typical velocity of propagation (%): Max. DCR (Ohm/km): 91 Nominal capacitance (pf/m): Diameter of insulated conductor (mm): 1.17 Nominal overall diameter (mm): 7.2 Impedance (Ohm): 1 MHz: ± 15 % 2 MHz: ± % Single E 0 ENH 5 1 ft. 0 m.9 kg 0 ft. 0 m.0 kg Belden E+ Bonded pairs Braided Cat. Belden ENH+ Halogen-free version Product description Shielded Twisted Pair Cable, 4 x AWG. Solid bare copper conductors, polyolefine insulation, overall foil shield and tinned copper drain wire and tinned copper braid. Colour code: see DataTwist colour code table on page. Applicable industry standards: EN 1, ISO / IEC 01 Attenuation (db/ m) NET (db) PS-NET (db) PS-ELFET (db) ACR (db/ m) PS-ACR (db/ m) max. (Cat. ) Typical velocity of propagation (%): Max. DCR (Ohm/km): 91 Nominal capacitance (pf/m): Diameter of insulated conductor (mm): 1.17 Nominal overall diameter (mm): 7.5 Impedance (Ohm): 1 MHz: ± 15 % 2 MHz: ± % Single E 0 ENH 5 1 ft. 0 m 2.5 kg 0 ft. 0 m.9 kg Table of Contents
15 ISTP Category 7 Belden 15ENH Halogen-free Cat. 7 Belden 17ENH Twin version of 15ENH Product description Shielded Twisted Pair Cable, 4 pairs x AWG. Solid bare copper, foam skin polyolefin insulated, pairs individually shielded with Aluminum/Polyester foil, overall tinned copper braid, ripcord, flame retardant. Colour code: see DataTwist colour code table below. Applicable industry standards: EN 1, ISO / IEC 01 Attenuation (db/ m) NET (db) PS-NET (db) PS-ELFET (db) ACR (db/ m) PS-ACR (db/ m) max. (Cat. 7) Standard colour: Grey Velocity of propagation (%): Max. DCR (Ohm/km): Nominal capacitance (pf/m): Diameter of insulated conductor (mm): 1. Nominal overall diameter (mm):.0 Impedance (Ohm): 1 MHz: ± 15 % 2 MHz: ± % 2 0 MHz: ± % Single Twin ENH ft. 0 m.0 kg 0 ft. 0 m.0 kg Ordering Information & DataTwist Colour Code Table Page Belden part number E, ENH 17E, 17ENH A, ANH E, ENH 1592A* 17A* 79E, 79ENH E, ENH 1A, 1ANH 1GB* A, NH 1797B 1E, 1ENH 1E, 1ENH A, ANH 1E+, 1ENH+ 1E+, 1ENH+ 1E, 1ENH E, ENH E+, ENH+ 15ENH 17ENH * Halogen-free version available upon request. DataTwist colour code table: Pair no. 1 White/Blue & Blue Pair no. 2 White/Orange & Orange Pair no. 3 White/Green & Green Pair no. 4 White/Brown & Brown Colour Grey (RAL ), Blue (RAL 15) Grey (RAL ) Grey (RAL ), Blue (RAL 15) Grey (RAL ) Grey, Blue (RAL 15), Red, Green, Yellow (RAL), Orange, Violet, White, Black Grey, Blue (RAL 15), Red, Green, Yellow (RAL), Orange, Violet, White, Black Grey (RAL ), Blue (RAL 15) Grey (RAL ), Blue (RAL 15) Grey, Gold, Brown, Blue (RAL 15), Red, Green, Yellow (RAL), Orange, Violet Grey, Blue (RAL 15), Red, Green, Yellow (RAL), Violet, White, Black Grey, Blue (RAL 15), White Cable preparation tool (White) Grey (RAL ), Blue (RAL 15) Grey (RAL ) Grey, Blue (RAL 15) Grey (RAL ), Blue (RAL 15) Grey (RAL ) Grey, Blue (RAL 15), Red, Green, Yellow (RAL) Grey (RAL ), Blue (RAL 15) Grey (RAL ), Blue (RAL 15) Grey (RAL ) Grey (RAL ) Notes: Special put-ups available upon request. Packaging on non-returnable reels, unreel box (U-5 m) or reel in box (A-5 m). Table of Contents Standard lengths (put-ups) U-5 m, 5 m, 0 m, 0 m 5 m, 0 m, 0 m U-5 m, 5 m, 0 m, 0 m 5 m, 0 m, 0 m U-5 m, 5 m U-5 m, 5 m 0 m, 0 m U-5 m, 0 m, 0 m m, A-5 m A-5 m, 5 m A-5 m, U-5 m, 5 m 5 m, 0 m, 0 m 5 m, 0 m, 0 m U-5 m, 5 m, 0 m 5 m, 0 m, 0 m 5 m, 0 m, 0 m 5 m, 0 m, 0 m 0 m, 0 m 0 m, 0 m 0 m, 0 m 0 m, 0 m
16 Belden across the globe Europe: The Netherlands (European Headquarters) Belden Wire & Cable B.V. Edisonstraat PG Venlo The Netherlands Phone: Fax: [email protected] Web: France Belden Electronics S.A.R.L. Immeuble Le César, Place Louis Pradel 9001 Lyon France Phone: Fax: + 9 Hungary Belden Dunakabel Kft. Hengermalom Str. 1 Budapest Hungary Phone: Fax: Italy Belden International Inc. Via Paracelso 2 Centro Direzionale Colleoni Palazzo Cassiopea Ingr. 3 Agrate Brianza (MI) Italy Phone: Fax: Russia Belden Office Moscow UL. Gubkina, Moscow Russia Phone/Fax: Sweden Belden Wire & Cable B.V. Stadshusplatsen 2 1 Nynäshamn Sweden Phone: + 02 Fax: + 0 United Kingdom Belden Communications Division Delaunays Road, Blackley Manchester. M9 FP United Kingdom Phone: Fax: [email protected] Web: World-wide: Africa/ Middle East Belden Wire & Cable Dubai Internet City Building One, Suite P.O. Box 01 Dubai United Arab Emirates Phone: Fax: Australia Belden Australia Pty. Ltd. Olympia Street Tottenham, Victoria Australia Phone: Fax: Canada Belden Canada Inc. 1 Willmott Street Cobourg, Ontario Canada K9A 4M3 Phone: Fax: Singapore Belden International, Inc. 1 Thompson Road, #07-02 United Square Singapore 91 Phone: Fax: +0 2 United States Belden Wire & Cable Co. P.O. Box 190 Richmond, IN 5 United States Phone: Fax: All sales of Belden products are subject to Belden s terms and conditions of sale. All printing errors are subject to correction. Technical specifications are subject to change without notice. The author reserves the right not to be responsible for the topicality, correctness, completeness or quality of the information provided. Liability claims regarding damage caused by the use of any information provided, including any kind of information which is incomplete or incorrect, will therefore be rejected. Copyright 3, Belden Inc Reprinting and reproduction, in whole or in part, prohibited.
Communication, Signal & Data Cables
Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication
Specification SFTP CAT6 Network Cable 23AWG CU
Specification SFTP CAT6 Network Cable 23AWG CU S/FTP CAT6 Shielded S/FTP PVC Cable 23AWG 4pair Solid, Wooden drum 1000 Grey CAT6 600MHZ CM Shielded (S/FTP) Solid Cable: Our CAT6 600MHZ Shielded (S/FTP)
RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables
RoHS DATA, COAXIAL AND ELECTRONIC D A TA, C O A X I A L, A N D EL E CTRON I C Cables Index SOLID MULTI-CONDUCTOR CABLES STRANDED MULTI-CONDUCTOR CABLES SPEAKER/ZIP WIRE THERMOSTAT CABLE FIRE ALARM CABLE
DATA SHEET SERVO LK SMS FX8PLUS SIGNAL
Application LAPP servo cables according to Siemens * (see footnote) Standard FX8008 PLUS SIGNAL are a new generation of very highly flexible screened signal (encoder and resolver)- cables (P/Ns 00277101
Coaxial Cables. for Broadband Communication Networks. European Edition
Coaxial Cables for Broadband Counication Networks European Edition Dependable Solutions in Cabling Better by design Our strategic objective is to provide our customers with superior solutions for their
Coaxial Cable Solutions Guide
Coaxial Solutions Guide General offers a complete line of Carol Brand Coaxial s for today s sophisticated high-speed, wide-bandwidth electronics products that run over long distances with minimal signal
Copper Cabling Infrastructure Offering
Copper Cabling Infrastructure Offering High-Speed Copper Cabling Systems The deployment of high speed cabling systems has been increasing rapidly as data centers enable their physical infrastructure with
TFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB
Type: TU6T60-JVB Dielectric 2nd Outer (w/optional Floodant) Series 6 Coaxial Cable Copper Clad Steel Foamed Polyethylene Dielectric Bonded AP Laminate Shield 60% Aluminum Braid "Life Time" compound AP
ETHERLINE Ethernet Cable, Connectors & Tools
Ethernet Cable, ors & Tools 2 Pair 242 4 Pair 249 Industrial Ethernet ors & Tools 256 Ethernet Cable, ors & Tools ETHERNET CABLE, CONNECTORS & TOOLS Quick Select Chart 240 2 Pair 2 Pair: CAT.5/5e; Stationary
Cable Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell's Genesis Series provides a full range
HONEYWELL SECURITY & CUSTOM ELECTRONICS Cable Products Honeywell's Genesis Series provides a full range of low voltage cables for security, fire, sound, voice and data, video, structured cabling and other
Gulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES Irrigation 1 Coaxial s for T.V/ Satellite Antenna etc 2 Data Transmission s - 4 pair 24 AWG 3 TELEPHONE CABLES Telephone cables CCP-LAP & CCP-LAP-SS
Uniprise Solutions COAX 101. White Paper. www.commscope.com
Uniprise Solutions COAX 101 White Paper www.commscope.com Structured cable systems have very thorough standards for fiber optic and twisted pair installations. The cabling components and installed systems
Network Engineers Everywhere:
Network Engineers Everywhere: Relax Your Minds Not Your Standards DataMax Commercial Ethernet Patch Cable The Strongest Link. DataMax Commercial Ethernet Patch Cable The Strongest Link. DataMax Patch Cable
Analog Multi-Pair Snake Cable High-Flex and NEC Rated Cables
B R I L L I A N C E B R O A D C A S T C A B L E S 19.16 High-Flex and Rated Cables Especially designed for the broadcast industry, Belden s full faily ulti-pair audio Snake cables feature options and construction
HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)
Cable Specification Category 5e CMP HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP) This cable specification complies with the electrical transmission
TECHNICAL SPECIFICATION
TECHNICAL SPECIFICATION 4 PAIR UTP CABLE (ENHANCED CATEGORY 5) PVC (CM Grade) Page 1 of 6 1. SCOPE This specification is based on the specifications of UL 444, ANSI/TIA/EIA-568-B.2, UL 1685 and covers
COAX Cables Radio Frequency Cables
COAX Cables Radio Frequency Cables Contents Page Table of contents Pictographs General information Introduction Types and abbreviations Temparature range Construction Characteristics Special constructions
Commercial Coaxial Cable
Commercial Coaxial Cable For the Best in COMMERCIAL TV Reception Solutions! Do you require a Digital TV reception system for your next project? Matchmaster can supply For The Best Design and supply of
EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.
EcoFlex Cable Smaller. Lighter. Tougher. 100% Recyclable. Total Performance, Completely Recyclable EcoFlex cable is Alpha Wire s newest innovation in control cabling. A true engineering breakthrough, EcoFlex
CAVEL VS80205 MADE IN ITALY 1000 V
0,05 9,00 x 7,20 (Pet) (LSZH) Attached CE01 CE02 Sheath Colour black black red Non-migrating Polyester tape longitudinally overlapped (Pet) 25 x 23 µm Outer sheath of Thermoplastic material - black - halogen-free,
Sound, Alarm & Security Cable 7
Electronics Sound, Alarm & Security Cable 7 Index Page The sound and security industry in the United States has grown from a simple and unsophisticated business, begun some 45 years ago, to one which has
Serial Data Grade Cables
VGA INPUT MONITOR OUT VGA INPUT MONITOR OUT 3.5mm STEREO MINI 3.5mm STEREO MINI L R Audio L R Audio AUDIO INPUTS + - + - AUDIO INPUTS + - + - AMPLIFIED OUTPUT 4/8 ohm COM 70V 100V AMPLIFIED OUTPUT 4/8
Outside Telephone Cable
Outside Telephone Cable Filled Core. Moisture Barrier. Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Filled core, conformed by groups of pairs or by unit of
West Penn Wire. Access Control Systems and Cables WEST PENN WIRE CABLE WITH CONFIDENCE
West Penn Wire Access Control Systems and Cables Access Control Cables AWG Size CARD READER CABLES # of Cond. CMR Shielded CMP Shielded CMR Unshielded CMP Unshielded 22 4 3241 253241B 241 25241B 22 6 3270
Cable 101: Introduction to Belden Wire & Cable Company
Cable 101: Introduction to Belden Wire & Cable Company Presented By: Belden Engineering Center Staff Belden Wire & Cable Company OVERVIEW Who is Belden? Belden is a world leader in the field of signal
Cable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection
Cable Guide Cables, Connectors & Tools for installation of quality networks TRIAX - your ultimate connection A Selection of the best Triax TX Cable range optimised for digital reception Simplification
The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects
The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects White Paper /7/0 Executive Summary Now that the TIA/EIA-568-B.- Category 6 Copper Cabling
Standard Buccaneer - Ethernet
IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version
108-93018 05 APR 2016 Rev M
Product Specification 108-93018 05 APR 2016 Rev M Copper LAN Cable 1. SCOPE 1.1. Content This specification describes the general requirements for CommScope copper LAN cable. 2. APPLICABLE DOCUMENTS The
E Series. E Series. Category 6 and 5e. Features
E Series Category 6 and 5e CommScope, world leader in copper and fiber connectivity, offers the E Series product line as the ideal solution to all your infrastructure needs for safe and reliable data transmission.
Copper Cables CONNECTIVITY & CABLING SYSTEM
Copper Cables CONNECTIVITY & CABLING SYSTEM Category 5E M0502057-91 EN CPR 6707 U/UTP tested up to 200 MHz U/UTP CAT5E, unshielded 4-pair cable (100 Ohm), with PVC or LSZH (Low Smoke Zero Halogen) outer
Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.
1 Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. Topics to be covered: Cable identification Purpose of the various cable types Installation techniques Building Infrastructure Overview of networking
Flexible and safe solutions, for decades. Cables for alarmand safety systems
Flexible and safe solutions, for decades. Cables for alarmand safety systems 2 We offer the widest range of cables on the market for every kind of installation. It s all about reliability. It is always
with Component Rating A Simple Perspective
Cat-6A UTP and Shielded with Component Rating A Simple Perspective Asef Baddar RCDD, DCD Sr. Technical Manager Leviton Middle East Category Specifications Agenda Terminology International & North America
PROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN
for PROFIBUS-PA and -DP 10/63-6.46 EN CPN 080/CPE 080-Ex PROFIBUS-PA basis cable AWG 18, 0.88 mm 2 Use For fixed installation indoor and outdoor, on racks and in conduits. Application Fieldbus cable for
CCTV System Troubleshooting Guide
Wouldn t be nice to start and finish a CCTV System Project without running into any problems before, during and after the installation is completed. Well, in this article we will try and explain why we
Coaxial Cables for Medium-Frequency Applications
Coaxial Cables for Medium-Frequency Applications Coaxial Cables for Medium-Frequency Applications Introduction Telecommunications technology is moving forward rapidly and the need for fast and reliable
Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER
Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER Questions to Ask When Planning the Cabling Plant Planning a copper cabling plant to support 10Gbps transmission
Coaxial Cable 5. Electronics
Electronics Coaxial Cable 5 Index Page Coaxial Solutions Guide 86-87 88-93 RG 8/U Type 94-95 96-99 To meet the needs of today s sophisticated, high-speed, wide bandwidth electronics over long distances,
MICROCABLES. A complete vision of your connectivity needs. Catalogue
MICROCABLES A complete vision of your connectivity needs Catalogue ELECTRONIC Filotex Introduction Application Nexans s line of microcables is designed towards the increasing requirements of electronics
LS Data Communication Product
www.lscable.com 2007 LS Cable, Ltd. All right reserved. This product or document is protected by copyright and distributed under licenses restricting its use, copying, distribution, and decompilation.
75 Ω Transmission System
NRAO NTC-DSL Laboratory Report Dynamic Spectroscopy Laboratory Report Series Report 03 September, 2006 75 Ω Transmission System Chaitali R. Parashare Department of Electrical and Computer Engineering,
The Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom
The Quality Connection Cable Solutions for Mobile Networks Business Unit Telecom Connection Technology for Wireless Communication Systems A consistent focus on the market, in-depth sector and product knowledge,
Broadcast and Commercial AV Cabling MASTER CATALOG
Broadcast and Commercial AV Cabling MASTER CATALOG Clark Wire & Cable 408 Washington Blvd. Mundelein, IL 60060 800-222-5348 toll free 847-949-9944 local 847-949-9595 fax www.clarkwire.com Specifications
Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair
Presentation; Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair 5 th April 2010 Paul Mathews MInstSMM, CCNA, MIEEE Global Channel Manager Media Types Physical Layer Cabling;
ULTIMATE SNAP-N-SEAL
ULTIMATE SNAP-N-SEAL F Series Compression Connectors Thomas & Betts introduces the Ultimate Snap-N-Seal Compression Connector, the newest addition to the Snap-N-Seal system. Look for the classic design
Cables. Indoor, Outdoor, HDMI, CAT, connectors. Cables, connectors and tools
Indoor, Outdoor, HDMI, CAT, connectors, connectors and tools Indoor Outdoor Fly leads HDMI CAT F -/IEC connectors F -/IEC adaptors F - terminator Connection cables Power cables and electricity articles
DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION
DIVISION 26 - ELECTRICAL PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Instrumentation Cables 1.02 SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit
Security & Control Cables
Security & Control Cables Our multi-conductor cables are manufactured in a wide variety of gage sizes, shielding configurations and jacketing materials including plenum, riser and general purpose. Applications
Outdoor Carrier Class Shielded Ethernet Cable. Datasheet. Models: PRO, CARRIER, Connectors. Increase Performance. Extreme Weatherproof
Datasheet Outdoor Carrier Class Shielded Ethernet Cable Models: PRO, CARRIER, Connectors Increase Performance Extreme Weatherproof ESD Damage Protection Extended Cable Support 1 2Datasheet Protect your
Total Solutions Verification
Total Solutions Verification 3rd Party Electrical Performance Testing Author: Tom Boucino Applications Engineer Uniprise Solutions CommScope has always designed cables with connectivity in mind. Our engineers
WIRE & CABLE PRODUCTS
WIRE & CABLE PRODUCTS Parallel Speaker Wire 1 leg printed for polarity, ETL or UL Listed CM 77001 UZ1802-9B5 White 18/2 conductor (7/26) parallel speaker wire, 1 leg printed "UL NEC 800 or ETL listed"
Instrumentation Cable...14-17. Power Cable...2-11. Assembly Solutions...32
Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant Assemblies...3-33 Ester Based Mud
The Quality Connection. High Performance Cable Solutions for the World of Semiconductors
The Quality Connection High Performance Cable Solutions for the World of Semiconductors 2 Total Flexibility for Applications with the Toughest Requirements LEONI is your long-term, reliable partner supplying
The Quality Connection. High Performance Cable Solutions for the World of Semiconductors
The Quality Connection High Performance Cable Solutions for the World of Semiconductors 2 Total Flexibility for Applications with the Toughest Requirements LEONI is your long-term, reliable partner supplying
BLACK BOX. Secure network ports from unauthorized access and accidental disconnects.
FC black process black LockPORT Security Patch Cables CAT5e, CAT6 and Fibre 5th black Secure network ports from unauthorized access and accidental disconnects. BLACK BOX» LockPORT cables stay locked in
6000 Series Buccaneer
Robust, instant connections for harsh environments 6000 Series Buccaneer - circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available
HARTING Ethernet Cabling 8-poles Overview
Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs
Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk
Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk Paul Vanderlaan Product Development Engineer Belden Presented at BICSI January 20, 1999 Introduction New Parameters involving
les ab C eration en G ew N
NewGeneration Cables BELDEN Cable TM Table of Contents New Generation Cables Page Introduction 13.2 New Generation Cable Finder Guide 13.3 13.6 Security and Alar Cable 13.7 13.26 Unshielded Multi-conductor:
SYSTIMAX Solutions. GigaSPEED X10D Shielded (F/UTP, S/FTP) Solution Guide Europe, Middle East and Africa Regions. www.commscope.
SYSTIMAX Solutions GigaSPEED X10D Shielded (F/UTP, S/FTP) Solution Guide Europe, Middle East and Africa Regions www.commscope.com The SYSTIMAX GigaSPEED X10D Shielded Solution provides unprecedented performance
Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC. by Paul Kish NORDX/CDT Chair TIA TR 41.8
Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC by Paul Kish NORDX/CDT Chair TIA TR 41.8 Outline Market trends Standards development where we were where we are where we are going Beyond Category
ATT-TP-76440 Ethernet Copper Cable & Ethernet Copper Assembly Specification
ATT-TP-76440 Ethernet Copper Cable & Ethernet Copper Assembly Specification Abstract Presented in this document are the standards to implement Electrical & Optical Ethernet components, cabling, connections,
Precision Video Cable for Analog and Digital Overview
B R I L L I A N C E B R O A D C A S T C A B L E S 19.49 Overview Analog Video Belden precision video cables are used in critical analog and digital video circuits and high quality applications such as
RF & Microwave cable assemblies C291
ERTIFIED C AS 9100 RF & Microwave cable assemblies C291 B CONTENTS Pages Introduction... B-4 Specify the right cable for your application... B-5 Finder guide cables vs insertion loss... B-6 to B-7 Flexible
1236421A5-N/3GT30G-FLEX3-75 Conector Hembra, Crimp Tipo 1.0/2.3 (PUSH-PULL), 75 Ohm. Cable:Flex 3 /75
CONECTORES COAXIALES RF 1.0/2.3 1.0/2.3 1.0/2.3 www.intersac.pe 1231111L1-002-N/5GT5G-75 Conector Macho, Crimp Tipo 1.0/2.3 (PUSH-PULL), 75 Ohm. Cable:Flex 3 /75 1236421A5-N/3GT30G-FLEX3-75 Conector Hembra,
Category 6 Solutions. 4. Category 6 Solutions. 09/08 400836IN TrueNet Structured Cabling. Introduction... 4.2. Cable... 4.3. Patch Panels... 4.
Category 6 Solutions Introduction... 4.2 Cable... 4.3 Patch Panels... 4.4 Modules... 4.6 Patch Cords... 4.12 Outlets... 4.16 Faceplates...4.18 4. 1 Search Category 6 Solutions Introduction ADC KRONE s
The Permanent Link in Field Certification Reasons, Advantages, Testing Challenges
The Permanent Link in Field Certification Reasons, Advantages, Testing Challenges Table of contents Channel, Basic Link and Permanent Link defined....................... 2 Critical Performance Parameters......
Category 6 UTP - Cabling System
AMP NETCONNECT Category 6 UTP Cabling System...... real Category 6 Performance, both on Component as well as on System level! Owing to the extreme high performance of the AMP NETCONNECT Category 6 UTP
Communication and Control Cable 1-3 6. Fire Alarm Cable 4 7-6 0. Coaxial Cable ( CAT V / M ATV & CCTV Cables) 6 1-7 8
West Penn Wire Cables Communication and Control Cable 1-3 6 A q u a s e a l C a b l e & Process Control Cables (600 Volt) 37-46 Fire Alarm Cable 4 7-6 0 Coaxial Cable ( CAT V / M ATV & CCTV Cables) 6 1-7
Products. Technology. Services. Delivered Globally. LOW-VOLTAGE CABLING SOLUTIONS
Products. Technology. Services. Delivered Globally. LOW-VOLTAGE CABLING SOLUTIONS THE ANIXTER DIFFERENCE We understand your growing challenge of competing in today s business climate and your need to continuously
The Next Generation of Cable Technology. A technology primer from NORDX/CDT By, Eric d Allmen
A technology primer from NORDX/CDT By, Eric d Allmen Foreword The Telecommunications Industry Association (TIA) and the International Standards Organization (ISO/IEC) are actively engaged in the development
Accelerating Light. Copper Cabling Solutions. Category 6A
Accelerating Light Copper Cabling Solutions Category 6A Category 6A Copper Cabling Solutions Fibernet designs and manufactures premium, high performance copper communication infrastructure and connectivity
IT Cabling Solutions
IT Cabling Solutions Signamax & Hitachi Cable America System Performance Signamax & Hitachi Cable America (Hitachi) system quality assurance testing is based on the worst-case model - four-connector 100-meter
Data Communications Competence Center
Importance of Cable Balance For Improving Noise Susceptibility Data Communications Competence Center DCCC03101702 July 11, 2007 Summary In a study of category 5e and category 6 UTP cables, a strong correlation
INDOOR PHONE INSTALLATION (CONCEALED) TECHNICAL SPECIFICATION
TÜRK TELEKOMÜNİKASYON KASYON A.Ş. DIRECTORSHIP OF OPERATION AND MAINTENANCE Operation Directorate of Access Networks INDOOR PHONE INSTALLATION (CONCEALED) TECHNICAL SPECIFICATION ANKARA 2008 CONTENTS 1.
Industrial Ethernet The Perfect Cable for an Imperfect Environment
1 Industrial Ethernet The Perfect Cable for an Imperfect Environment Written by: David Fausz, Engineer, Communications Products TABLE OF CONTENTS BACKGROUND 1 APPLICATIONS AND 2 ELECTRICAL PERFORMANCE
How to Choose the Right Cable Category
How to Choose the Right Cable Category Why do I need a different category of cable? Not too long ago, when local area networks were being designed, each work area outlet typically consisted of one Category
Flexible Control Cables
Works photo: KUKA Flexible Control Cables A Flexible Control Cables Since generations people try to build machines and plants which shall take on different functions. To raise, sink, slide, drill, transport
Standards Affecting a Premise T-1 Installation
Standards Affecting a Premise T-1 Installation The T-carrier system originated many years ago as a technology developed by AT&T. The intended use of the scheme was to increase the voice channel capacity
C 060 CCTV Coaxial Cable
C 060 CCTV Coaxial Cable These cables are used for video transmissons of CCTV applications..4...... Coaxial Cable (C 060).. Inner Conductor : Ø 0.60 mm Bare Copper.. Insulation : Ø.80 mm Gas-injected Foam
PANDUIT TX6 10GIG SHIELDED COPPER CABLING SYSTEM. Innovative Connectivity Solution for Maximum Performance and Security
PANDUIT TX6 GIG SHIELDED COPPER CABLING SYSTEM Innovative Connectivity Solution for Maximum Performance and Security Gigabit Ethernet over Copper With ever increasing bandwidth requirements, advancements
Network Design. Yiannos Mylonas
Network Design Yiannos Mylonas Physical Topologies There are two parts to the topology definition: the physical topology, which is the actual layout of the wire (media), and the logical topology, which
Panduit 28 AWG Patch Cords Installation Guideline
Panduit 28 AWG Installation Guideline Introduction Panduit is a leading supplier of Structured Cabling Systems and Unified Physical Infrastructure. Panduit solutions enable the physical infrastructure
Product Bulletin. One Enterprise. One Infrastructure. One Partner. Shielded Cabling Systems
Product Bulletin PB373 Shielded Cabling Systems Belden s complete portfolio of shielded Category 6A, Category 6 and Category 5e Systems offer superior performance, outstanding reliability and effective
Solving Signal Problems Effective shielding is key to enhancing the reliability and performance of broadcast cables.
Solving Signal Problems Effective shielding is key to enhancing the reliability and performance of broadcast cables. by Marty Van Der Burgt Belden Article for Broadcast Engineering There is perhaps no
CIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*
Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Available in Standard and Arctic Grade Jackets n Highly
Características. Starligh SA 9 de julio 1595 Córdoba Argentina - 0351-4809210 / 4119600
Balun Activo - BALUN_ACT Características Single Channel Active Video Transmitter Full-motion color video signal up to 3900ft(1200m) via UTP cat5e/6 NTSC, PAL & SECAM video format compatible Real-time transmission
RGB Component Video Cable Bundled RGB Coaxial Cables Miniature and High-Flex Type
B R I L L I A N C E B R O A D C A S T C A B L E S 19.69 RGB Coponent Video Cable Bundled RGB Coaxial Cables Miniature and High-Flex RGB coaxial cables are used for sending red, green and blue signals through
This paper will explain some of the more important factors on how UTP wires work; specifically it will cover the following:
UTP Technology In the late 1970s, unshielded twisted pair (UTP) cabling originated in the computer industry as a means of transmitting digital data over computer networks. This cable was designed to be
Copper Patch Cords. Impact On Network Performance and Reliability
Copper Patch Cords Impact On Network Performance and Reliability 1 The Impact of Copper Patch Cords on Network Performance and Reliability As network infrastructures continue to have a higher impact on
with coloured cores and overall copper screen UL/CSA... 17
CONTENT Cable Track Cables y SD 200 extremely flexible TPE/PUR data cable with coloured cores for continuous movement..... 6 y S 200 extremely flexible TPE/PUR control cable with numbered cores for continuous
HARTING Ethernet Cabling 4-poles Overview
Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] HARTING PushPull Connectors [on page 22] System cables [on page 24] Panel feed-throughs [on
coaxial cable coaxial Cable CERTIFIED 100% certified coaxial cable A cable that is marked Televés, no doubt is a certified cable
COAXIAL CABLE coaxial Cable 100% certified coaxial cable coaxial cable CERTIFIED The step ahead undertaken by Televés to improve its service and technical excellence, is now reflected in this new challenge.
Terminating 25-Pair Cable and 4-Pair Cross Connects
Terminating 25-Pair Cable and 4-Pair Cross Connects Estimated Time: 90 minutes Number of Teams: 2 Number of Team Members: one to four This Lab has four major parts that will be addressed separately. 1.
RF cables. Edition 2015
RF cables Edition 2015 Developed for highest expectations Your partner for system solutions HUBER+SUHNER is a leading international producer and supplier of electrical and optical interconnectivity components
CABLE TERMINATION BEST PRACTICES A guide to improved cable performance through proper termination and installation.
B E C A U S E Y O U R B U S I N E S S R U N S T H R O U G H U S CABLE TERMINATION BEST PRACTICES A guide to improved cable performance through proper termination and installation. Outstanding products
CommScope-SYSTIMAX Solutions UTP Cable... 2.2 2.6. Berk-Tek UTP... 2.19 2.24. STP and F/UTP Cable... 2.37 2.38. Solutions Blanks and Dust Covers 2.
2 Section 2 Product or Vendor Name Copper Cable Solutions Product or Vendor Name...000 000 CommScope-Uniprise Solutions CommScope-SYSTIMAX Solutions UTP Cable... 2.2 2.6 Patch Panels and Accessories.........