Copper Pre-terminated Assemblies

Size: px
Start display at page:

Download "Copper Pre-terminated Assemblies"

Transcription

1 Copper Pre-terminated Assemblies

2 Copper Pre-Terminated Trunk Assemblies Overview Copper Pre-Terminated trunk assemblies are the perfect solution for Enterprise / Premise & Data Centre applications where speed of installation is important. Factory termination and testing simplify installation, saving time and labour when compared to field terminated installations. Bespoke configurations in pre-engineered lengths with connectors to meet the specific needs of each application. Assemblies are typically built with a choice of 6 or 12 cable bundle using LSZH jacket. Standards compliant premium connectors and cable are used to ensure the best possible headroom and performance. Testing All preterms are 100% factory tested using the latest tier 3 tester; hard copy results for each link are packed with every preterm. Soft copy results are available upon request. Components We only use premium components for the production of our copper pre-terminated trunk assemblies to ensure the highest possible headroom. Construction Trunk assemblies are supplied in bundles of either 6 or 12 cables. A braided sleeve is applied to preterms up to 15mtrs in length and break out points are secured with heat shrink. Each link is labeled with corresponding port numbers as standard bespoke labeling requirements can be arranged at the time of order. Assemblies above 15mtrs will be bundled together using hook and loop tie wraps. Packaging Each preterm breakout is covered with a bubble wrap pocket to ensure protection of connectors during transportation, each coiled assembly is then packed and heat sealed into a PE bag and test results attached. Long length assemblies will be coiled and supplied in a cardboard box. 2

3 Contents Warranty Programme 4 Page INSTALLATION TIME REDUCED Copper Pre-terminated Trunk Assemblies Overview 5 Application Scenarios 6 Pre-terminated Solutions 8 Configuration Guide 9 Bespoke Patch Cords / Drop Cables 10 Accessories 11 QUICK MOVES, ADDITIONS AND CHANGES HIGH DENSITY VERSIONS AVAILABLE Copper Pre-terminated Assemblies Brochure 3

4 1Typical Application Scenario Enterprise / Premise Jack - Surface Box 1 Jack - Jack 2 Jack - Plug 3 Jack - Open End Jack to Jack Ideal for fast installation of the permanent link, panel to panel application requires the use of an empty keystone panel frame ( ) supplied separately. Patch cords would then be used to complete the channel between active equipment (i.e. servers and switches). Jack or Plug to Open End Used in applications similar to the Jack-to-Jack configuration, but one end would be terminated to a PCB panel instead of an unloaded keystone panel. This termination type requires field testing of the drops after the cables have been terminated. Jack to Surface Mounted Box Ideal for simple moves, adds and changes on the office floor, the jacks are installed into a unloaded panel frame and patched into the relevant active equipment. The surface mounted box can be positioned into the desired location in the work area where users PC s can be patched into the network. Jack to Plug Eliminates one cross-connect point by installing the RJ45 plug directly into the active equipment (i.e. switches). The keystone jack termination snaps into the unloaded panel, which would then be patched to other active equipment or work area ports as necessary. 4

5 2Typical Application Scenario Data Centre Jack - Plug 1 LGX - Plug Jack - Jack 2 LGX - LGX The Keystone LGX is a 6 way cassette to enable installation of keystone jacks into our 1U sliding panel S13XXX00 (up to 18 ports) or the 3U Chassis (up to 84 ports). This system can also be combined with any of our Fibre LGX configurations allowing a mixture of copper and fibre in one panel. This solution is perfect for data centre applications where high density installations are a must. 1 LGX to Plug The LGX Plug assembly eliminates one cross-connect point by installing the RJ45 plug directly into the active equipment (i.e. switches). 2 LGX to LGX Ideal for fast installation of the permanent link, panel to panel application. Patch cords would then be used to complete the channel between active equipment (i.e. servers and switches). Copper Pre-terminated Assemblies Brochure 5

6 An overview to the Copper pre-terminated trunk assemblies Pre-terminated Solutions Jack to Jack Jack Jack to Plug Jack Jack to Open End Jack Plug to Open End Plug LGX to LGX LGX Module LGX to Plug LGX Module LGX to Open End LGX Module

7 Jack Plug Open End Open End LGX Module Plug Open End Copper Pre-terminated Assemblies Brochure 7

8 An overview to the Copper pre-terminated trunk assemblies Configuration Guide Connector End A Cable Distribution Connector End B Keystone Jack Unscreened (Female) Cat 5E UTP Staggered Keystone Jack Unscreened (Female) Keystone Jack Screened (Female) Cat 5E FTP Fan Out Keystone Jack Screened (Female) RJ-45 Plug Unscreened (Male) Cat 6 UTP RJ-45 Plug Unscreened (Male) RJ-45 Plug Screened (Male) Cat 6 FTP RJ-45 Plug Screened (Male) Open End Cat 6A U/FTP Open End Part Number Generator QTCT Cable Bundle Screen Lenght (m) End A End B 5E 5E 06 U/UTP UT 10 10L Jack K Jack K C6 C6 12 F/UTP FT 12 12L Plug R Plug R 6 A 6A 14 14L Open O 16 16L 18 18L Example Part Number: 20 20L QTCT C6 12 UT 16L K R QTCTC612UT16LKR has created a CAT 6 UTP 12 way jack - plug copper trunk 16 mtrs Please Specify exact length requirement and distribution requirements (Staggered or Fan out) upon ordering. For individual cable and component performance and technical data please view relevant data sheets. 8

9 Complementary products Bespoke Patch Cords / Drop Cables Optronics can offer a quick turn around solution for copper patch cords and drop cables. Our UK production facility is geared to satisfy customer requirements for fully bespoke patch cords. Service Features > > Bespoke lengths > > Rare colour options > > Special pin configurations > > Special labelling / packaging requirements > > No MOQ > > Quick Turn around production Drop Cables allow connection and access to and from the trunk cables of a network such as the cables that connect individual PCs to the bus on a bus LAN. In a CATV system, the transmission cable from the distribution cable to a dwelling. Optronics can produce custom drop cables to satisfy your individual requirements. As standard these are produced using stranded cable for lengths up to 10mtrs and solid cable for lengths above 10mtrs. Jack (female) to Plug (Male) drop cables are available in Screened and unscreened solutions over CAT5e and CAT6. CAT6A drop cables are supplied as a screened solution only. Patch Cords Part Number Configurator QTCP 45 Cable Screen Lenght (m) Jacket 5E 5E U/UTP UT 01 PVC P C6 C6 F/UTP FT 02 LSZH L 6 A 6A Example Part Number: Drop Cables Part Number Configurator QTCP 5E 45 UT 01 P QTCP5E45UT01P has created a quick turn copper patch lead - CAT 5E RJ-45 U/UTP up to 1 metre PVC Please Specify exact length, colour and part number configuration at time of order. DRP Cable Screen Lenght (m) Jacket 5E 5E U/UTP UT XX m PVC Where XX is the length XXM in metres C6 C6 F/UTP FT LSZH 6 A 6A Example Part Number: DRP C6 FT 10M LSZH DRPC6FT10MLSZH has created a CAT 6 F/UTP male - female 10 metres LSZH drop cable Copper Pre-terminated Assemblies Brochure 9

10 Complementary products Accessories LGX Style RJ-45 Keystone Jack Module This innovative and robust LGX style keystone jack module. has been designed to accept 6 unscreened or screened RJ-45 keystone jack, and deliver reliable performance upto category 6A. With the ability to use LGX style footprint, Optronics offers a unified and modular platform for both fibre and copper solution. Description Unloaded 6 way keystone LGX cassette Part Number L08XXX00 Unloaded 1U Keystone Patch Panel 24 Port Unloaded 1U 19 patch panel 24 port for mounting cat. 5e, 6 and 6a keystone jacks, it can be used for screened and unscreened solutions. Description Part Number Unloaded 1U 19 keystone patch panel 24 port Single Gang Bevelled UK style single gang bevelled faceplate. Suitable for installing 1 to 2 ports. Dimensions: 86 x 86mm Description Part Number Single Gang Faceplate Bevelled 1-2 port Double Gang Bevelled UK style double gang bevelled faceplate. Suitable for installing 1 to 4 ports. Dimensions: 86 x 146mm Description Part Number Double Gang Faceplate Bevelled 1-4 port Blanks Blanks & unloaded angled module. Fits with any UK style faceplates. Description Part Number 50 X 25mm Blank X 12.5mm Blank X 25mm Angled module European Angled Insert European style curved faceplate. Comes with unloaded modules in 1 or 2 port versions. Description Part Number Optronics Angled Insert 45 x 45 Single Port Optronics Angled Insert 45 x 45 Double Port

11 Warranty programme A trusted 25 year product & life application warranty Optronics offer one of the most complete warranty programmes available to the structured cabling industry. Our copper and fibre solutions are designed for performance and reliability and manufactured to comply with the latest national and international standards at the time of installation. The Optronics cabling system exceeds the performance requirements defined within ISO/IEC 11801, ANSI/EIA/TIA 568 and EN 50173, as applicable, and is warranted against manufacturing defects for a period of 25 years from the date of installation. Furthermore, FibreFab Ltd will also warrant a complete Optronics system to support for the lifetime of the installation all applications that have been designed to run on the specific CLASS/Category of cabling system for 25 years, providing that the components have been installed and tested by an Optronics certified integrator. > > Optronics cabling solutions are warranted to support all and any applications designed to operate over the installed class of cabling system > > Optronics products are warranted for a period of 25 years as being free from manufacturing defects that could jeopardise the mechanical, electrical or transmission line performance and reliability > > Warranty only available through the approved partner network > > The warranty can be transferred to new building owners The Optronics copper and fibre structured cabling range represents the relentless pursuit by the brand to bring quality and reliability to the market. Achieved through world class engineering we have confidence to stand behind our products and the applications they support for 25 years in the full knowledge that they will continue to faultlessly deliver the applications for which they were designed for a life-time. to faultlessly deliver the applications for which they were designed for a life-time. (Please refer to the Optronics 25 year warranty document for terms and conditions) Copper Pre-terminated Assemblies Brochure 11

12 Optronics Limited Tel: +44 (0) Version 3.0 Copyright Optronics 2013 All Rights Reserved E&OE OPTCOPPRETERM Products are covered by GB and other patents and/or patents applied for: Pre-Terminated Cable Breakout Module, UHD Modular System and Shuttered Quad Adaptor and FirstLight is a registered trademark MTP is a registered trademark of US Conec

Accelerating Light. Copper Cabling Solutions. Category 6A

Accelerating Light. Copper Cabling Solutions. Category 6A Accelerating Light Copper Cabling Solutions Category 6A Category 6A Copper Cabling Solutions Fibernet designs and manufactures premium, high performance copper communication infrastructure and connectivity

More information

Category 6 UTP - Cabling System

Category 6 UTP - Cabling System AMP NETCONNECT Category 6 UTP Cabling System...... real Category 6 Performance, both on Component as well as on System level! Owing to the extreme high performance of the AMP NETCONNECT Category 6 UTP

More information

Excel Pre-terminated Copper and Fibre Optic Systems

Excel Pre-terminated Copper and Fibre Optic Systems Excel Pre-terminated Copper and Fibre Optic Systems Excel is a world-class premium performing end-to-end infrastructure solution - designed, manufactured, supported and delivered - without compromise.

More information

DATA CENTRES POWERED BY EXCEL

DATA CENTRES POWERED BY EXCEL DATA CENTRES POWERED BY EXCEL MAXIMISE EFFICIENCY BOOST PERFORMANCE INCREASE R.O.I. WITHOUT COMPROMISE Excel is a world-class premium performance end-to-end infrastructure solution. Designed, manufactured,

More information

InstaPATCH Cu Cabling Solutions for Data Centers

InstaPATCH Cu Cabling Solutions for Data Centers SYSTIMAX Solutions InstaPATCH Cu Cabling Solutions for Data Centers Design Guidelines August 2008 www.commscope.com Contents Overview 1 Instapatch Cu Solution Specification 2 Harness Assembly Design 3

More information

Patch Cords / Cable / Cable Assemblies. Patch. Cords/Cable/ Premise Connectivity Systems. Cable Assemblies

Patch Cords / Cable / Cable Assemblies. Patch. Cords/Cable/ Premise Connectivity Systems. Cable Assemblies Patch Cords / Cable / Cable Assemblies Premise Connectivity Systems Patch Cords/Cable/ Cable Assemblies w w w. s i g n a m a x. c o m Category 6A 10G Patch Cords C1 Patch Panels and Cross- Category 6 Patch

More information

Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8

Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8 Data Center Guide 1 Our Philosophy As a leader in the enterprise cable industry since our inception over three decades ago, we can help you implement the solution that will work best for your cabling infrastructure,

More information

Cabcon. Data Centre Solutions. www.cabcon.co.uk. an acal group company UK +44 (0)1189 122980 IRE (00353) 1 629 2640

Cabcon. Data Centre Solutions. www.cabcon.co.uk. an acal group company UK +44 (0)1189 122980 IRE (00353) 1 629 2640 Data Centre Solutions www.cabcon.co.uk UK +44 (0)1189 122980 IRE (00353) 1 629 2640 About Us are a specialist distributor of copper, fibre, power, security, active and cable management products for the

More information

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair Presentation; Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair 5 th April 2010 Paul Mathews MInstSMM, CCNA, MIEEE Global Channel Manager Media Types Physical Layer Cabling;

More information

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation Data Center Pre-terminated Patch Panel System Patch Panels Plug & Play Installation 10G + Gigabit Patch Cords Bundled + Labeled Cabling Systems Simplified Our Mission At Cablesys, our mission is to simplify

More information

Category 6 Solutions. 4. Category 6 Solutions. 09/08 400836IN TrueNet Structured Cabling. Introduction... 4.2. Cable... 4.3. Patch Panels... 4.

Category 6 Solutions. 4. Category 6 Solutions. 09/08 400836IN TrueNet Structured Cabling. Introduction... 4.2. Cable... 4.3. Patch Panels... 4. Category 6 Solutions Introduction... 4.2 Cable... 4.3 Patch Panels... 4.4 Modules... 4.6 Patch Cords... 4.12 Outlets... 4.16 Faceplates...4.18 4. 1 Search Category 6 Solutions Introduction ADC KRONE s

More information

Data Centre & Enterprise Solutions. RapidNet

Data Centre & Enterprise Solutions. RapidNet H E L L E R M A N N T Y T O N Data Centre & Enterprise Solutions RapidNet data centre & Enterprise solutions HellermannTyton is a leading global manufacturer of network cabling solutions which connect,

More information

E Series. E Series. Category 6 and 5e. Features

E Series. E Series. Category 6 and 5e. Features E Series Category 6 and 5e CommScope, world leader in copper and fiber connectivity, offers the E Series product line as the ideal solution to all your infrastructure needs for safe and reliable data transmission.

More information

IT Cabling Solutions

IT Cabling Solutions IT Cabling Solutions Signamax & Hitachi Cable America System Performance Signamax & Hitachi Cable America (Hitachi) system quality assurance testing is based on the worst-case model - four-connector 100-meter

More information

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS . HARTING RJ INDUSTRIAL ETHERNET CONNECTORS Ethernet is is coming up to standard industrial interface. Therefore, automation devices such as controllers, sensors and actuators feature possess on one or

More information

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications 3M Telecommunications Solutions for Networks Volition Network Solutions Leading the way in Network Migration through Innovative Connectivity Solutions Innovation The Broadband Migration Path 3M TM Volition

More information

Data Center Cabling Design Trends

Data Center Cabling Design Trends Data Center Cabling Design Trends BICSI Regional Meeting Maurice Zetena Fiber Connect Infrastructure Trends Infrastructure Trends Any to All Trunk Cabling Trends: Data Center Infrastructure Media Choice:

More information

MPO. Fast Fibre Solution for Data Centres

MPO. Fast Fibre Solution for Data Centres MPO Fast Fibre Solution for Data Centres Benefits The Plug & Play MPO solution of Nexans Cabling Solutions provides a comprehensive line of pre-terminated and pre-tested assemblies to meet the current

More information

HARTING Ethernet Cabling 4-poles Overview

HARTING Ethernet Cabling 4-poles Overview Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] HARTING PushPull Connectors [on page 22] System cables [on page 24] Panel feed-throughs [on

More information

HARTING Ethernet Cabling 4-poles Overview

HARTING Ethernet Cabling 4-poles Overview Ethernet Cabling 4-poles Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] Connectors [on page 22] System cables [on page 24] Panel feed-throughs

More information

How To Make A Fibre Cable For A Data Centre

How To Make A Fibre Cable For A Data Centre LANmark-OF Fibre Optic Solutions for Data Centres Complex Data Centres require fibre solutions CORE SWITCH ACCESS SWITCH SERVER SAN SWITCH LANmark-OF Slimflex Patch Cords LANmark-OF Single Mode LANmark-OF

More information

C6 A modul and C6 A modul K. The new connection system for all applications of course with Cat.6 A

C6 A modul and C6 A modul K. The new connection system for all applications of course with Cat.6 A C6 A modul and C6 A modul K The new connection system for all applications of course with Cat.6 A Intelligent solution for structured cabling systems There is an enormous need for high data transfer rates

More information

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide GB05-6 Peak Atlas IT RJ45 Network Cable Analyser Model UTP05 Designed and manufactured with pride in the UK User Guide Peak Electronic Design Limited 2001/2012 In the interests of development, information

More information

Requirements for Modular Patch Cords (e.g. RJ45 patch cords for Cat5 and Cat6 cabling systems)

Requirements for Modular Patch Cords (e.g. RJ45 patch cords for Cat5 and Cat6 cabling systems) Requirements for Modular Patch Cords (e.g. RJ45 patch cords for Cat5 and Cat6 cabling systems) Introduction The purpose of this document is to: 1) provide background information beneficial to specifiers

More information

Innovative Connectivity Solution for Maximum Performance and Security

Innovative Connectivity Solution for Maximum Performance and Security Innovative Connectivity Solution for Maximum Performance and Security Financial Institutions Supports high performance backbone which enables transfer of real-time financial information through voice,

More information

ADC Structured Cabling Solutions

ADC Structured Cabling Solutions ADC Structured Cabling Solutions The highest performing cross-connect system in the world HighBand Wall Mount Patching Solution Reliable, secure and cost effective ADC s HighBand cross connect solution

More information

Security & Surveillance Cabling Systems

Security & Surveillance Cabling Systems Security & Surveillance Cabling Systems Security and Surveillance Cabling Systems The video security industry is growing and ever-changing, offering a wealth of opportunity for today s security professionals.

More information

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below: Washington University in St. Louis Building: Communication Specification: Research Voice/Network/Typical 1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

More information

LANC Fibre Patch Panel Solution

LANC Fibre Patch Panel Solution features and benefits Modular front with interchangeable fibre optic adapter modules Quick mount feature (teardrop design) Port numbers printed above and below adapter modules High-density using LC connectivity

More information

AMP NETCONNECT Data Center Cabling Solutions

AMP NETCONNECT Data Center Cabling Solutions AMP NETCONNECT Data Center Cabling Solutions Modern business and administrative environments require today more and more sophisticated IT services, what leads to an increasing demand for data provision

More information

The Need for Speed Drives High-Density OM3/OM4 Optical Connectivity in the Data Center

The Need for Speed Drives High-Density OM3/OM4 Optical Connectivity in the Data Center The Need for Speed Drives High-Density OM3/OM4 Optical Connectivity in the Data Center Doug Coleman, Manager, Technology & Standards, Corning Cable Systems Optical connectivity with OM3/OM4 laser-optimized

More information

Installation Manual For Support Call 01704 807114 or email info@hipentertainment.co.uk

Installation Manual For Support Call 01704 807114 or email info@hipentertainment.co.uk Installation Manual Hip Smart Hub (Standard BT and BT FTTP Sites) The Home Network Hub houses the Home Owner s Broadband Router and connects the hardwired network ports on that Router to three network

More information

www.commscope.com Data Center Topology Guide

www.commscope.com Data Center Topology Guide www.commscope.com Data Center Topology Guide Data Center Areas 1 Network Operations Center (NOC) The network operations center or NOC is the location where control of all data center networking, server

More information

SYSTIMAX Solutions. GigaSPEED X10D Shielded (F/UTP, S/FTP) Solution Guide Europe, Middle East and Africa Regions. www.commscope.

SYSTIMAX Solutions. GigaSPEED X10D Shielded (F/UTP, S/FTP) Solution Guide Europe, Middle East and Africa Regions. www.commscope. SYSTIMAX Solutions GigaSPEED X10D Shielded (F/UTP, S/FTP) Solution Guide Europe, Middle East and Africa Regions www.commscope.com The SYSTIMAX GigaSPEED X10D Shielded Solution provides unprecedented performance

More information

Quick Reference Guide High Speed Input/Output Solutions

Quick Reference Guide High Speed Input/Output Solutions Quick Reference Guide The pluggable I/O interface offers significant advantages as a high speed I/O interconnect. With a standard equipment I/O interface and the flexibility of pluggable modules come the

More information

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module R&Mfreenet Advanced R&Mfreenet Advanced Cat 6 A Connection Module The R&Mfreenet Cat 6 A unshielded connection modules, part of the Advanced cabling system, are ideal for voice, fast data transmissions

More information

MTP Solutions. MPO High Performance Fibre Optic Solutions for Data Centres SMARTER GLOBAL CONNECTIONS

MTP Solutions. MPO High Performance Fibre Optic Solutions for Data Centres SMARTER GLOBAL CONNECTIONS MTP Solutions MPO High Performance Fibre Optic Solutions for Data Centres SMARTER GLOBAL CONNECTIONS 1 MTP Solutions for High Density Networks The Right MTP Solution Reduce deployment time and improve

More information

Simpler all over. Simpler all round. 500 MHz. 10 GB ether. fully shielded. Poe+ Cat.6 A. Data Voice. MFP8 Cat.6 A Field assembly RJ45 plug

Simpler all over. Simpler all round. 500 MHz. 10 GB ether. fully shielded. Poe+ Cat.6 A. Data Voice. MFP8 Cat.6 A Field assembly RJ45 plug Simpler all over. Simpler all round. No special tools required for field ASSEMBLY Cat.6 A 10 GB ether. 500 MHz fully shielded Poe+ Data Voice MFP8 Cat.6 A Field assembly RJ45 plug Less fuss. More flexibility.

More information

How To Set Up A Minipatch System For A Small Office Or Home Use

How To Set Up A Minipatch System For A Small Office Or Home Use Issue : 4 Wood Communications Networking Products Catalogue Small Office & Home Solution Small Office / Home Solution Min LAN Comms Cabinets - Multimedia Panel - Soho Ethernet Switches - Multiroom Audio/Video,

More information

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications. Issued 2005/06/01 Section 16743 Data System Page 1 of 7 PART 1 GENERAL 1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications..2 Data system equipment

More information

1U Multi-Function Fibre Enclosure

1U Multi-Function Fibre Enclosure FEATURES AND SPECIFICATIONS Features and Benefits The is a configurable rack mount unit for storing and terminating incoming fibre cable. The fibre enclosure has been designed to accommodate various termination

More information

MTP Optical Fibre Configurations

MTP Optical Fibre Configurations MTP Optical Configurations ackground The Excelerator MPO range from Excel utilises the MTP Elite connector manufactured by US Conec. The range is made up of: MTP to MTP Trunk Cables MTP to LC s MTP Patch

More information

Case Study. Molex PDS Delivers Voice and Data Streams around Shanghai Unicom Tower

Case Study. Molex PDS Delivers Voice and Data Streams around Shanghai Unicom Tower , the headquarters office of China Unicom Shanghai Branch, is a 26-floor building located at 1031 Changning Road, Shanghai. The cabling system (PDS) to be installed here is to carry all the voice and data

More information

The migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations

The migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations The migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations White Paper www.commscope.com Contents Introduction 3 CommScope solution overview 3 InstaPATCH

More information

BIX Cross-Connect System Distribution Connectors, Multiplying Connectors and Modular Jack Connectors

BIX Cross-Connect System Distribution Connectors, Multiplying Connectors and Modular Jack Connectors C O M M E R C I A L N E T W O R K I N G C O P P E R 15.13 Distribution Connectors, Multiplying Connectors and Modular Jack Connectors A0393146 QCBIX1A4 Connector BIX Distribution Connector The BIX Distribution

More information

DATA CENTER NETWORK INFRASTRUCTURE. Cable and Connectivity for the Most Demanding Networks. BerkTekLevitonTechnologies.com

DATA CENTER NETWORK INFRASTRUCTURE. Cable and Connectivity for the Most Demanding Networks. BerkTekLevitonTechnologies.com DATA CENTER NETWORK INFRASTRUCTURE Cable and Connectivity for the Most Demanding Networks Customer-focused, technology-driven, quality-assured for an unparalleled RETURN ON infrastructure investment DATA

More information

Performance Verification of GigaSPEED X10D Installations with Fluke Networks DTX 1800 CableAnalyzer

Performance Verification of GigaSPEED X10D Installations with Fluke Networks DTX 1800 CableAnalyzer SYSTIMAX Solutions Performance Verification of GigaSPEED X10D Installations with Fluke Networks DTX 1800 CableAnalyzer Issue 2 Draft 1 June 2010 Contents Overview 3 GigaSPEED X10D Guaranteed Channel Performance

More information

Enterprise Networks EMEA. Core Products FOR DATA CENTRES

Enterprise Networks EMEA. Core Products FOR DATA CENTRES Enterprise Networks EMEA Core Products FOR DATA CENTRES EMEA Data Centre Core Products 1 Data Centres GET IT RIGHT, Right Now. Corning Cable Systems offers tens of thousands of fibre optic products for

More information

Issues Affecting the Design and Choice of Cabling Infrastructures within Data Centres

Issues Affecting the Design and Choice of Cabling Infrastructures within Data Centres Issues Affecting the Design and Choice of Cabling Infrastructures within Data Centres White Paper Nexans Cabling Solutions September 2006 Executive Summary Planning for the unknown is always a difficult

More information

Living Infrastructure

Living Infrastructure Living Infrastructure Design Guide for Data Centers Table of Contents Introduction...1 Data Center Overview...2 Choose a Pod Design...3 Considerations for the Typical Data Center...4 Solution 1: End of

More information

Data Center Infrastructure Development

Data Center Infrastructure Development Data Center Infrastructure Solution Agile & Efficient Agile, Efficient & Highly Available Data Centers Data center deployment is at the heart of most IT strategies. Designing a data center that responds

More information

What are the requirements for a Home Network?

What are the requirements for a Home Network? What are the requirements for a Home Network? Setting up a computer network in your home is not rocket science but it pays to think about what you want/need before you start buying equipment or drilling

More information

The High Cost of a Low-Cost Cable Certification Tester

The High Cost of a Low-Cost Cable Certification Tester The High Cost of a Low-Cost Cable Certification Tester How much does it cost? That is typically the first question a cabling contractor or network owner asks when considering a new certification tester

More information

Project files. Customer copy Legrand copy

Project files. Customer copy Legrand copy 20 years warranties Project files Structured cabling Systems categories 6A, 6 & 5e Customer copy Legrand copy TO BENEFIT FROM LEGRAND WARRANTIES 1 Complete and sign the Identity document: Worksite details*,

More information

InstaPATCH ZERO Solution Guide

InstaPATCH ZERO Solution Guide SYSTIMAX Solutions InstaPATCH ZERO Solution Guide Rapid Server Deployment and Change Management North, South and Central Americas 1 As data centers face ever-increasing IT demands, growth demands and evolving

More information

HydraPort 12 Module Connection Ports HPX-1200SL, Brushed Aluminum (FG560-03-SL) HPX-1200BL, Black Anodized (FG560-03-BL)

HydraPort 12 Module Connection Ports HPX-1200SL, Brushed Aluminum (FG560-03-SL) HPX-1200BL, Black Anodized (FG560-03-BL) DATA SHEET HydraPort 12 Module Connection Ports HPX-1200SL, Brushed Aluminum (FG560-03-SL) HPX-1200BL, Black Anodized (FG560-03-BL) Overview With space for up to 12 modules, the HPX-1200 allows you to

More information

NTU Data Communications Cabling Specification

NTU Data Communications Cabling Specification NTU Networking Standards Document Circulation List NTU Data Communications Cabling Specification Purpose of this Document This document sets out the specification required for NTU data communications cabling

More information

7.1 id Intelligent Infrastructure Management. 7.2 id Active

7.1 id Intelligent Infrastructure Management. 7.2 id Active 7 HellermannTyton has a range of hardware products for use with Intelligent Infrastructure Management software. Page Page 7.1 Intelligent Infrastructure Management Category 6 Patch Leads 194 Category 5e

More information

Masterseal Plus TM. ingress protected wiring devices. technical hotline +44 (0) 1268 563720. www.mkelectric.com IP66. Improved catch.

Masterseal Plus TM. ingress protected wiring devices. technical hotline +44 (0) 1268 563720. www.mkelectric.com IP66. Improved catch. Masterseal Plus TM technical hotline +44 (0) 268 63720 Improved catch Rear drill holes Available in grey, white and black Fixed gasket speds installation gasket Now has all the features and logic plus

More information

AMP NETCONNECT. EMEA Product Catalog

AMP NETCONNECT. EMEA Product Catalog AMP NETCONNECT EMEA Product Catalog What s New! & System Selector What s New...2 System Selector... 4 Table of Contents AMP NETCONNECT Systems by Name 1. MRJ21 System... 9 2. Sigma-Link System...15 3.

More information

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels

More information

Plug & Play Gigabit Ethernet Media Conversion Module. Application Note

Plug & Play Gigabit Ethernet Media Conversion Module. Application Note Plug & Play Gigabit Ethernet Media Conversion Module Application Note The Plug & Play Universal Systems Media Converter Module offers the best of both worlds easy fiber optic scalability and future proofing

More information

Dlp-s & WIRING DEVICES. THE MAXIMUM FReeDOM OF ChOICe. SNAP-ON AND UNIVERSAL TRUNKING FOR high AND LOW CURReNt DIStRIBUtION

Dlp-s & WIRING DEVICES. THE MAXIMUM FReeDOM OF ChOICe. SNAP-ON AND UNIVERSAL TRUNKING FOR high AND LOW CURReNt DIStRIBUtION Dlp-s & WIRING DEVICES THE MAXIMUM FReeDOM OF ChOICe SNAP-ON AND UNIVERSAL TRUNKING FOR high AND LOW CURReNt DIStRIBUtION the global specialist IN electrical AND DIGItAL BUILDING INFRAStRUCtUReS Be free

More information

Managing High-Density Fiber in the Data Center: Three Real-World Case Studies

Managing High-Density Fiber in the Data Center: Three Real-World Case Studies Managing High-Density Fiber in the Data Center: Three Real-World Case Studies CHALLENGE In today s data center, fiber optic links have become more vital than ever for transmitting data to and from a large

More information

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber Introduction Migration Strategy for 0G and 00G Ethernet over Multimode Fiber There is a need for increased network bandwidth to meet the global IP traffic demand, which is growing at a rate of 0% per year

More information

AMP NETCONNECT CABLING SYSTEMS FOR DATA CENTERS & STORAGE AREA NETWORKS (SANS) High-density, High Speed Optical Fiber and Copper Solutions

AMP NETCONNECT CABLING SYSTEMS FOR DATA CENTERS & STORAGE AREA NETWORKS (SANS) High-density, High Speed Optical Fiber and Copper Solutions AMP NETCONNECT CABLING SYSTEMS FOR DATA CENTERS & STORAGE AREA NETWORKS (SANS) High-density, High Speed Optical Fiber and Copper Solutions TABLE OF CONTENTS TABLE OF CONTENTS... 2 INTRODUCTION... 3 CABLING

More information

The AMP NETCONNECT Cabling System Products

The AMP NETCONNECT Cabling System Products The AMP NETCONNECT Cabling System Products About the AMP NETCONNECT Business Unit The AMP NETCONNECT business unit of Tyco Electronics develops, manufactures and supplies a comprehensive range of communications

More information

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W) Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W) Table of Contents Introduction.. Power Over Ethernet (PoE) & Features.... Unpacking and

More information

Splitter Solutions Brochure. www.fibrefab.co

Splitter Solutions Brochure. www.fibrefab.co Splitter Solutions Brochure www.fibrefab.co 2 Splitter Solutions Central Office Buildin Node / Distribution Point Underground Enclosure 1U to Zero U 1 1 for further specifications see page 4 2 for further

More information

Audio, power, and control data

Audio, power, and control data Shure DIS Cabling Best Practices Introduction The Shure DIS conferencing system operates on an isolated network of microphone units, interpretation stations, and additional conference accessories. Referred

More information

SHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS

SHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS STRUCTURED CABLING SHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS INTRODUCTION In recent years, communications have taken on a crucial role in development for businesses. Communications

More information

Panduit 28 AWG Patch Cords Installation Guideline

Panduit 28 AWG Patch Cords Installation Guideline Panduit 28 AWG Installation Guideline Introduction Panduit is a leading supplier of Structured Cabling Systems and Unified Physical Infrastructure. Panduit solutions enable the physical infrastructure

More information

Rack & Stack 123 TM. Enterprise Education Government Telecommunications Service Providers Tel: 408-586-8800

Rack & Stack 123 TM. Enterprise Education Government Telecommunications Service Providers Tel: 408-586-8800 Rack & Stack 123 TM Enterprise Education Government Telecommunications Service Providers Tel: 408-586-8800 Rack & Stack 123 TM Introduction Simplicity Scope of Work Rack & Stack 123 TM Benefits 2 toll-free:

More information

Structured and Point to Point Network Cabling for Industrial Automation

Structured and Point to Point Network Cabling for Industrial Automation Structured and Point to Point Network Cabling for Industrial Automation Introduction Industrial automation systems are undergoing dramatic transformations that require businesses to adopt new strategies

More information

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Revised Sept--22-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Description The sealed circular RJ45 connector system is designed for use in harsh environments. The connector

More information

Ethernet Cat 5e & Cat 6 Patch Panels

Ethernet Cat 5e & Cat 6 Patch Panels Ethernet Cat e & Cat Patch Panels Copper :: RJ/IDC Models EPPE-CTE & EPPE-CAT User Manual Applys to : EPPE-CTE :: EPPE-CAT Telect, Inc., All Rights Reserved, 9- A0.09.9.000 :: telect.com Ethernet Cat e

More information

HARTING Ethernet Cabling 8-poles Overview

HARTING Ethernet Cabling 8-poles Overview Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs

More information

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording Hardware & Installation Guide Algo Communication Products Ltd. Customer Support and Sales Tel: 1.877.884.2546 Fax: 604.437.5726 Email: sales@algosolutions.com support@algosolutions.com www.algosolutions.com

More information

Data Centers Re-Enforce Best Practices To Assure Optimal Installation Quality and Maximize Margins For 10GBASE-T"

Data Centers Re-Enforce Best Practices To Assure Optimal Installation Quality and Maximize Margins For 10GBASE-T Data Centers Re-Enforce Best Practices To Assure Optimal Installation Quality and Maximize Margins For 10GBASE-T" Christian Schillab Product Manager InfrastructureSuperVision Fluke Networks Europe Member

More information

Data Center Infrastructure Solution

Data Center Infrastructure Solution Data Center Infrastructure Solution AGILE, EFFICIENT & HIGHLY AVAILABLE DATA CENTERS Data center deployment is at the heart of most IT strategies. Designing a data center that responds to the needs of

More information

Enterprise Networks EMEA. Core Products FOR DATA CENTRES

Enterprise Networks EMEA. Core Products FOR DATA CENTRES Enterprise Networks EMEA Core Products FOR DATA CENTRES EMEA Data Centre Core Products 1 Data Centres GET IT RIGHT, Right Now. Corning Cable Systems offers tens of thousands of fibre optic products for

More information

Cable Installation Project

Cable Installation Project Cable Installation Project 1. Intent. It is the intent of the U.S. Court of Appeals to install Category 6 (CAT6) data cabling in the Robert F. Peckham Federal Building and United States Courthouse, 280

More information

Product Bulletin. One Enterprise. One Infrastructure. One Partner. Shielded Cabling Systems

Product Bulletin. One Enterprise. One Infrastructure. One Partner. Shielded Cabling Systems Product Bulletin PB373 Shielded Cabling Systems Belden s complete portfolio of shielded Category 6A, Category 6 and Category 5e Systems offer superior performance, outstanding reliability and effective

More information

User Manual PT-E-HIP

User Manual PT-E-HIP User Manual PT-E-HIP PT-E-HIP User Manual Contents PT-E-HIP-TX Transmitter 1. Introduction 2. How It Connects 3. Features 4. Transmitter Unit Panel Layout PT-E-HIP-RX Receiver 5. Transmitter Unit Panel

More information

Video Splitter VS-104 / VS-108 User's Manual

Video Splitter VS-104 / VS-108 User's Manual Video Splitter VS-104 / VS-108 User's Manual VS-1048 07-11-02 Page 1 of 6 Packing Checklist 1 VS-104/VS-108 Video Splitter 1 DC 9V 300mA (min.) Power Adapter 1 User's Manual Please read this manual thoroughly

More information

Tyan Computer. Transport PX22. Service Engineer s Manual

Tyan Computer. Transport PX22. Service Engineer s Manual Tyan Computer Transport PX22 Service Engineer s Manual 1 Precaution To read through the user manual, check all assembly and follow setup process before any operation on this server To keep paper clips,

More information

LEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION

LEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION LEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION LEGRAND CABLING SYSTEM 2 LCS 2 Solutions from technical room to workstation See pages 02 to 13 LCS 2 copper See pages 14 to 21 LCS

More information

Specifying an IT Cabling System

Specifying an IT Cabling System Specifying an IT Cabling System This guide will help you produce a specification for an IT cabling system that meets your organisation s needs and gives you value for money. You will be able to give your

More information

CAT5 KVM Extender User Manual

CAT5 KVM Extender User Manual User Manual V2.1 2007.7.3 C o n t e n t s 1. Introduction... 3 1.1 Product Line... 4 1.2 Main Features... 5 1.3 Package contents... 6 1.4 Cables Diagrams... 6 1.4.1 3-in-1 DB15 Cable...6 1.4.2 3-in-1 CAT5

More information

Structured Cabling Statement of Work

Structured Cabling Statement of Work Structured Cabling Statement of Work Multiple Locations June 15, 2010 Page 1 A. GENERAL a. San Joaquin County (referred to as Owner ) is requesting proposals for a new structured cabling infrastructure

More information

Network Design. Yiannos Mylonas

Network Design. Yiannos Mylonas Network Design Yiannos Mylonas Physical Topologies There are two parts to the topology definition: the physical topology, which is the actual layout of the wire (media), and the logical topology, which

More information

Amphenol Industrial Automation Market

Amphenol Industrial Automation Market Amphenol LTW Technology Co., Ltd. Amphenol Industrial Automation Market http://www.amphenolltw.com Innovation in Waterproof Solution Amphenol LTW Our History LTW Technology, established in 1993, is a professional

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

THE IMPACT OF CURRENT TRENDS ON THE DATA CENTER COMMUNICATIONS CABLING INFRASTRUCTURE

THE IMPACT OF CURRENT TRENDS ON THE DATA CENTER COMMUNICATIONS CABLING INFRASTRUCTURE THE IMPACT OF CURRENT TRENDS ON THE DATA CENTER COMMUNICATIONS CABLING INFRASTRUCTURE Prepared by Michael Wood Senior Product Manager Data Center Infrastructure Systems Hubbell Premise Wiring www.hubbell-premise.com

More information

Infrastructure for the next three generations

Infrastructure for the next three generations Infrastructure for the next three generations Demand for bandwidth and storage is expanding at a breathtaking rate within the data center, which means that the environment is rapidly evolving, making the

More information

Home Cabling Installation Guide

Home Cabling Installation Guide Home Cabling Installation Guide Wiselan Home Cabling Installation Guide * This document should be treated as a guide only. In no way does it replace any regulation. This Document is subject to copyright

More information

Connector and Cable Specifications

Connector and Cable Specifications APPENDIXB This chapter describes the connector and cable specifications. Connector Specifications, page B-1l Cable and Adapter Specifications, page B-5 Connector Specifications 10/100/1000 Ports, page

More information