Attracting Data Centers to Your Market



From this document you will learn the answers to the following questions:

What is the name of the group that CB Richard Ellis practices?

What type of distribution paths does a data center have?

What is the main benefit of using a data center?

Similar documents
Data Center Management. Didik Partono Rudiarto CDCP, ITIL-F, COBIT5, CITM

100 Locust Avenue, Berkeley Heights, New Jersey P R O P E R T Y O F F E R I N G

Subject: County of Los Angeles Data Center Space Requirement

OPERATOR - FACILITY ADDRESS - DATE

AT&T Internet Data Center Site Specification Washington-DC Area (Ashburn, VA)

AT&T Internet Data Center Site Specification - Phoenix Area (Mesa, AZ)

19 Site Location, Design and Attributes. Site Location, Design and Attributes

N O W A V A I L A B L E

How To Visit An Internet Data Center

AT&T Internet Data Center Site Specification Chicago Area (Lisle, IL)

Building a Tier 4 Data Center on a Tier 1 Budget

Data Center Due Diligence List

Assessment of Existing Data Centers for Critical Facilities Round Table Group

LEVEL 3 DATA CENTER SERVICES IN OMAHA, NEBRASKA HIGH AVAILABILITY ENTERPRISE COMPUTING BUSINESS DEMANDS IT. LEVEL 3 DELIVERS IT.

Colocation Buyer s Guide and Checklist. A Playbook for Technology Managers

AT&T Internet Data Center Site Specification San Diego Koll (San Diego, CA)

Datacenter Assessment

N O W A V A I L A B L E

NORTHERN VIRGINIA ONE (NoVa) DATA CENTER OVERVIEW

Site Preparation Management Co., Ltd. March 1st 2013 By Nara Nonnapha, ATD UPTIME

Data Centers: Outsource or Own? Presented by: Rachel Dines, Forrester Research, Inc. Christopher Nicolini, Windstream Hosted Solutions

COMMODITIZING THE DATA CENTER MARKET

X-tier Data Facility. Prepared by X-tier SAE Corporation

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Presented by Edward P. Rafter, P.E., CxAP Tier IV Consulting Group

Data Center Commissioning: What you need to know

TELECOMMUNICATION SYSTEM HAZARD MITIGATION STRATEGIC PLANNING

T5 CHARLOTTE REGION WEST DATA CENTER PARK

Location. Central Business District. Ataturk Airport IFC. Sabiha Gökçen Airport

AT&T Internet Data Center Site Specification New York III (Secaucus, NJ)

Data Center Infrastructure & Managed Services Outline

Mike Johanns Governor

in other campus buildings and at remote campus locations. This outage would include Internet access at the main campus.

Business Services Park. General Description

Data Center Colocation Build vs. Buy

DATA CENTERS. VAZATA Headquarters: 6900 Dallas Parkway, Suite 800 Plano, TX VAZATA.COM

SLA. Co-Managed. Do-It-Yourself

Data Center:Build-to-Suit

NEW JERSEY CENTER OF EXCELLENCE

CyberFortress Data Center at Innovation Park Infrastructure and Topology Guide. Innovation Park Charlotte. NC DRAFT V0.

MINNEAPOLIS MARKET STREAM PRIVATE DATA CENTER CHASKA, MINNESOTA Ross Avenue, Suite 2800 Dallas, Texas 75201

Data Center CH1. Elk Grove Village, IL

Experience Matters...

STREAM PRIVATE DATA CENTER SAN ANTONIO MARKET WESTOVER HILLS Ross Avenue, Suite 2800 Dallas, Texas

STREAM PRIVATE DATA CENTER

DATA CENTERS. VAZATA Headquarters: 6900 Dallas Parkway, Suite 800 Plano, TX VAZATA.COM

AT&T Internet Data Center Site Specification Dallas Area (Allen, Tx)

South Asia s First Uptime Institute Certified TIER- IV IDC in Mumbai delivering % uptime

datacentersites.com Security, Infrastructure Redundancy Tier 3+/Tier 4 Data Center Sites

Digital Chicago. 600 south FeDeraL - chicago grand ave - FranKLin ParK 350 east cermak - chicago

About Injazat. Enterprise Cloud Services. Premier Data Center. IT Outsourcing. Learning and Development Services. Enterprise Application Services

Available Princeton Area Data Center / Disaster Recovery Lab / R&D

Data Center Site Qualification Program. Executive Summary

Dedicated Hosting Services

Safeguard your critical IT assets in a highly secure, fully redundant, environmentally-conditioned and constantly monitored hosting space to receive

Data Center Co- Location

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Wholesale Data Center Suites Available Now

The following are general terms that we have found being used by tenants, landlords, IT Staff and consultants when discussing facility space.

The Data Center Tier Performance Standards and Their Importance to the Owner s Project Requirements

Title: Design of a Shared Tier III+ Data Center: A Case Study with Design Alternatives and Selection Criteria

ISO IEC ( ) INFORMATION SECURITY AUDIT TOOL

DATA CENTERS. VAZATA Headquarters: 6900 Dallas Parkway, Suite 800 Plano, TX VAZATA.COM

MISSION CRITICAL FACILITIES DESIGN UPS BATTERY ROOM ENVIRONMENT CRITICAL DESIGN CONSIDERATIONS

Atlanta Business Park Industrial Profile

COLOCATION PROVIDERS:

Chicago 1 (CHI-1) Data Center

Datacenter Site Selection Checklist

Secure I Reliable I Flexible

san francisco//usa data center specifications tel: fax: internet + intellectual property + intelligence

NeuStar Ultra Services Physical Security Overview

How To Write An Infrastructural Standard For Data Center Infrastructure

Why Choose Go4Hosting Data Center?

Midwest s Premier Carrier Neutral Colocation Data Center Greater Minneapolis St. Paul, Minnesota

South Asia s First Uptime Institute Certified TIER-IV IDC in Mumbai delivering % guaranteed uptime

POWERING A CONNECTED ASIA. Pacnet Hong Kong CloudSpace1 Technical Specifications. Asia s Pioneering Facility with Direct Subsea Cable Access

Iron Hill Corporate Center Newark, DE

SolveXia Business Continuity Planning

Strategic Data Centre Site Profiles. Data Centre Co-Location London East

Should You Move to a Public Colocation Facility?

DATACENTER COLOCATION. Flexible, Secure and Connected

Heating & Cooling Efficiency

House your data in a building constructed for only one express purpose protect the information inside. Twin Cities East Data

disaster recovery - the importance of having a plan

NY2 21 CRITICAL MEGAWATTS 280,000 SQUARE FEET

Technical specifications. Containerized data centre NTR CDC 40f+

Contents Error! Bookmark not defined. Error! Bookmark not defined. Error! Bookmark not defined.

ASX Australian Liquidity Centre. ASXCoLo

Secure I Reliable I Flexible COPT DC Hornbaker Road, Manassas, Virginia

Reduce the cost and delays associated with troubleshooting with the help of round-the-clock Service Desk Support.

PEARL MANHATTAN, NY

Site Selection Search Presented To

Strategic Data Centre Site Profiles Data Centre Co-Location London North

Outline of Data Center Facility Standard

Santa Clara, CA 95054

Agility Logistics Datacenter Trends in Enterprises. Ben N. Hasnai VP IT Infrastructure and Operations

Data Center Overview Document

DATA CENTRE DATA CENTRE MAY 2015

Storm Ready. 3 Gulf Power Ready for the storm. 4 Be prepared, be safe. 5 Getting the lights back on. 6 Damage to your home s service connection

A Sustainable, Master-Planned Data Center Park.

Transcription:

Attracting Data Centers to Your Market A Presentation for: Presented by: Wendy McArthur, CB Richard Ellis

OVERVIEW Introduction Qualify Requirement Site Selection Cost Marketing CB Richard Ellis Page 2

INTRODUCTION CB Richard Ellis Page 3

INTRODUCTION Profile WENDY MCARTHUR, Vice President CB Richard Ellis Assists clients with the acquisition and disposition of data centers A Practice Leader in CB Richard Ellis Technology Practice Group & Member of AFCOM (Leading Association for Data Center Professionals) CB RICHARD ELLIS (CBRE) Largest Commercial Real Estate Company in the World Wide array of service lines touching nearly every industry type and support services such as Facilities Management and Project Management TECHNOLOGY PRACTICE GROUP (TPG) Seasoned CBRE professionals around the world specialize in the data center industry uniting their expertise, relationships and market intelligence in one powerful group TPG (150 members in 75 Global Markets) CB Richard Ellis Page 4

INTRODUCTION What is a Data Center? A physical place that houses a computer network's most critical systems, including back-up power supplies, air conditioning, and security applications. Data Centers are about equipment not people. Bunker type construction; Power, Fiber & Security are Critical CB Richard Ellis Page 5

QUALIFY REQUIREMENT CB Richard Ellis Page 6

QUALIFY REQUIREMENT Partial Checklist of Criteria Type of Data Center Primary or Back-up / Disaster Recovery (DR) Desired Tier Rating What s Driving the Need for this Data Center Relo, New, Consolidation, etc. Anticipated Power Requirement - Load Has a Program been Developed? Is a Team in Place? How will the Project be Funded? What s the Timing for Site Selection & for Occupancy? Any Preferred Fiber Provider(s) CB Richard Ellis Page 7

QUALIFY REQUIREMENT Tier Ratings Created by the Uptime Institute, the Tier Rating System is widely accepted as the de facto industry standard, to provide a consistent means to compare typically unique, customized facilities to each other from the perspective of expected site infrastructure availability, or uptime. The Tier Classification System is a benchmarking system to effectively evaluate data center infrastructure in terms of business requirements for uptime. Tier 1: Basic Infrastructure 99.67% Availability Tier 2: Basic Infrastructure w/ Redundancy 99.75% Availability Tier 3: Concurrently Maintainable 99.98% Availability Tier 4: Fault Tolerant 99.999% Availability (The five 9 s) CB Richard Ellis Page 8

SITE SELECTION REGION/ CITY CB Richard Ellis Page 9

SITE SELECTION REGION / CITY Partial Checklist of Criteria Cost & Availability of Electricity Risk Avoidance Natural Disasters Access to Telecommunication / Fiber Real Estate Availability & Affordability Access to City and to Facility Access to Technical Labor Pool Incentives CB Richard Ellis Page 10

SITE SELECTION REGION / CITY Electric Costs CB Richard Ellis Page 11

SITE SELECTION REGION / CITY Natural Disaster Maps CB Richard Ellis Page 12

SITE SELECTION REGION / CITY Fiber: North American & Regional Fiber Optic Long-Haul Routes CB Richard Ellis Page 13

SITE SELECTON SITE SPECIFIC CB Richard Ellis Page 14

SITE SELECTION SITE SPECIFIC Partial Checklist of Criteria Distance to power feed Diverse power feeds available Distance to fiber path / carriers Distance to dark fiber / owner Location of nearest Fiber Distance to nearest CO / CLEC Fiber path to CO / points of vulnerability Miles to Airports / flight path Distance from hazardous waste Any prohibitive environmental conditions (e.g. seismic activity, floods, etc.)? Catastrophic explosion risks Access to municipal sewer system Distance from rail line / type Distance to police / fire station Area flood plain Soil / rock stability Local demographics (neighborhood characteristics) Local traffic issues / concerns CB Richard Ellis Page 15

COST CB Richard Ellis Page 16

COST What Type of Requirement? Lease or Purchase Existing Data Center Keep apprised of any existing Data Center Inventory Understand the level of infrastructure Convert a Building to a Data Center Know which buildings have the most potential for conversion those with some level of Data Center Centric attributes (close to substation, access to fiber, bunker type construction, etc.) Have an understanding of Cost to Convert Construct a New Data Center Know which sites are best located for a Data Center (close to substation, access to fiber, affordably priced, away from freeways and rail lines, etc.) Have an understanding of Cost to Build CB Richard Ellis Page 17

COST Converting a Building to a Data Center Cost of Land.$3,000,000 Approx Total..$19,000,000 CB Richard Ellis Page 18

COST Building a New Data Center Cost Ranges $1,500+/sf Fault Tolerant Multiple independent & physically separate systems Each system has redundant components & multiple, independent, diverse & active distribution paths Unplanned & maintenance outages don t interrupt availability 99.99% availability Tier 4 $900 - $1,200/sf Concurrently Maintainable Sufficient MEP redundancy even when one of the MEP components has been removed from the infrastructure Unplanned & maintenance outages don t interrupt availability 99.98% availability Tier 3 $600 - $800/sf Basic Infrastructure with Redundant Components Single, non-redundant distribution path Unplanned outage can disrupt systems & users Maintenance doesn t disrupt availability 99.75% availability Tier 2 <$400/sf Basic Infrastructure with No Redundancy Basic power & cooling Unplanned outage disrupts systems & users Scheduled maintenance disrupts availability 99.67% availability Tier 1 CB Richard Ellis Page 19

COST Some of the Data Center Cost Components Structure Raised Floor Electrical Security Chilled Water Fire Suppression Cooling System Water Storage Fuel Storage Dual Feeds High Reliability Generators UPS System Cooling Tower Switch Gear CB Richard Ellis Page 20

MARKETING CB Richard Ellis Page 21

MARKETING Be Realistic Do you have the attributes to compete with other markets to attract out-of-market data center users or should you focus locally? Be Prepared Get Plugged into the data center community. (IT Contacts, Data Center Association, CIO s, Data Center Vendors, etc.) Know your market. (Sites and Owners, Power & Fiber Infrastructure, Vendors, etc.) Develop marketing materials. (Flyer / Brochure, Website, Site Information, etc.) Be Proactive Reach out to corporations, brokers and vendors. (don t wait on them to find you) Push informative information to prospective data center users. (Industry Trends, Cost Information, etc) CB Richard Ellis Page 22

MARKETING Sample Site Spec Sheet Criteria LOCATION Address / Description County Accessbility Natural gas Water Distance from expressway Distance from railroad Distance from substation General description of area Other data centers in the vicinity Any bio chemical facilities in the area Neighbors & uses SITE Size / acreage Zoning Notable topography characteristics Ingress / Egress Soil POWER Power Company Distance from substation Served by two substations? Type of feed (network, loop, etc) Underground or overhead service Cost of power / rate structure Service capacity available Description / Comment Edison Drive / near interstection of GA 400 & Windward Pkwy Fulton County Accessible via Georgia 400 (state highway) Yes, Atlanta Gas Light Yes, Fulton County > than 5 miles from Interstate Highway Greater than 5 miles Windward substation - 1.2 miles Corp office / data center environment with mix of retail Yes greater than 5 miles McKesson 75 acres Significant topograpical characteristics Soil Report Potential for dual substation feeds Underground AVAILABLE SITE Fiber Providers Dark Fiber FIBER AGL CB Richard Ellis Page 23

MARKETING Sample Brochures CB Richard Ellis Page 24

Base Building Characteristics Telecom Power / Power Distribution UPS / Power Generation HVAC Fire Detection / Suppression / Security MARKETING Sample Informative Piece Critical Facility - Real Estate Evaluation Issues Site Evaluation / Selection Distance to power feed / power capacity / power providers Distance to nearest sub-station Diverse power feeds available Distance to fiber path / carriers Distance to dark fiber / owner Location of nearest Telco manhole (if below grade) Distance to nearest CO / CLEC Telecom routing in street (above or below grade) Telco path to CO / points of vulnerability Distance to next nearest CO / CLEC Miles to Airports / flight path Miles to Nuclear Facilities Miles to closest hazardous waste sites Toxic contamination analysis Hazardous materials in the area Are there any prohibitive environmental conditions (e.g. seismic activity, floods, etc.)? Catastrophic explosion risks Access to well water Access to municipal sewer system Distance to nearest rail line / type Distance from police / fire station Area flood plain Soil / rock stability Local demographics (neighborhood characteristics) Local traffic issues / concerns Site Number of floors Total SF / SF per floor Column spacing Floor live load rating Slab to slab height / clear height Roof type / age Roof load rating Leak evidence Parking per square foot Perimeter wall materials / curtain wall Single or multi-tenanted building Age of the building / build-out HVAC system type / age / capacity Condenser type / location / capacity Chiller type / location / age Size / weight rating of freight elevator Size / internal height of freight elevator Number / configuration Loading dock access / turn radius Path / distance from dock to freight Hardened building rating Lightening protection Liquid or gas piping path Water service provider Sewage pumps / number Sewage pump redundancy Building automation system / brand Core / Shell Number and capacity of copper circuits / providers Number and capacity of fiber circuits / providers Dark fiber providers / termination points Nearest CO capacity / current utilization SONET capacity Voice telecom service providers / capacity and format Fiber services in the area / distance from site Available fiber splice locations Diverse telco path to site / path / conduit Telecom routing from street to site Telecom conduit type / size Location / protection of telecom access point Location / configuration of meet me room configuration Network distribution head end configuration Vertical cable distribution / conduit Cable management Fiber distribution Wireless WAN / IP providers Projected bandwidth growth Cellular coverage at building core / carriers Diverse power paths into building Capacity of each feeder (MVA / KW) Total electrical capacity to site Sub-station / switch yard configuration Power routing and POE configuration Provisions for expansion Current load vs. capacity Facility grounding type / internal / external Power monitoring systems Electrical distribution path Number of power busses Capacity of each buss Redundancy of busses / structure Internal power path Distribution panel circuit protection Surge protection Harmonic controls PDU type manufacturer /quantity /rating PDU monitoring capabilities Static transfer switch configuration Static switch manufacturer / quantity / rating Power distribution path Critical equipment power configuration Provisions for expansion UPS Capacity (KVA/KW) UPS configuration / number of busses System life with full load Location of battery facility Age of battery plant / last cell analysis Cell type / rating Provisions for UPS cell expansion Number and type of generators (diesel, natural gas, etc) Local gen-set operation ordnances / runtime limits Gen-set noise attenuation Gen-set emissions limitations Gen-set redundancy Gen-set location / internal / external Radiator / exhaust configuration Gen pads / portable gen-set capability Provisions for temporary or permanent genset expansion On site fuel storage capacity Fuel tank type / location Local fuel storage ordinances Full load / full tank gen-set run time Fuel supply lines path / day tank Fuel storage replenishment access Power transfer switch type / capacity Load bank capacity / installed or portable Facility Design / Construction / Evaluation Overall cooling capacity Summer / winter design temp Humidification Design humidity level Environmental control system Size / number of chillers / redundancy Location of chiller plant Coolant pump capacity Number of pumps Pump station location / containment pool Chilled water piping path / redundancy Chilled water pump redundancy Chilled water containment / drip pans Provision for chilled water expansion Data center air handlers Air handler redundancy A/C unit leak detection / containment Air flow/ air distribution method Adjustable air direction / air flow provision Amount of water storage available Redundant water source Condenser type / redundancy Condenser water piping redundancy Provision for condenser expansion Fire detection system VESDA / number of sample points Detectors above floor / below floor Fire command panel location Fire suppression type Fire panic stations Life safety equipment in DC Air filtration Perimeter protection / type Number of points of entry Man-traps at facility entrance Badge access security Biometric access controls / type CCTV systems / recorded / coverage Window type in critical area Window sheathing / type / bullet proof / caliber rating Sheetrock meshing / metal mesh Parking lot access control Loading dock access control Roof access control Basement access control Meet-me room access control Generator area access control Power / telecom entry point access control Security staff CB Richard Ellis Page 25

Data Center Incentives March 2010

Data Center Incentives State Incentives Sales Tax Exemption Job Tax Credits Quality Jobs Tax Credits Retraining Tax Credits Local Incentives Property Tax Abatements Accelerated Depreciation

Sales Tax Exemption Qualified NAICS 334413 334611 51121 51331 51333 51334 51421 52232 54133 54171 54172 513321 513322 514191 541511 541512 511513 511519

Job Tax Credit Processing - Establishments that are both primarily engaged in providing data processing services and included in NAICS 518210 Job Tax Credit $750 - $3,500 depending on tier level plus joint development authority and/or existing industry bonus if community is eligible Credits may be used to offset 50% - 100% state corporate income tax liability

Quality Job Tax Credit Qualifying criteria: At least 50 net new jobs Each job paying at least 110% of county average wage 50 jobs must be created within 12 months of first qualified job Based on percent paid above average county wage Tax credit first used to offset 100% state corporate income tax. Remaining credits may be applied against payroll withholding.

Retraining Tax Credit Data centers are an eligible business for the credit Up to $1,250 annually $500 maximum for a single training program Significant training

Local Incentives Real and Personal Property Tax Abatements Typically done through a bond issue How to incorporate future computer expenses Accelerated Depreciation Equipment becomes obsolete quickly Used 24-7 - 365

Data Center Incentives Georgia Department of Economic Development Corporate Solutions Team Mary Douglass, Director 404.962.4037 mzdouglass@georgia.org Blair Lewis, Project Manager 404.962.4833 blewis@georgia.org Valerie Gannon, Research Specialist 404.962.4034 vgannon@georgia.org Georgia Department of Economic Development 75 Fifth Street, NW Suite 1200 Atlanta, Georgia 30308