Approval Standard for Class 1 Exterior Wall Systems



Similar documents
Approval Standard for Flammability of Absorbent Battery Acid Spill Containment Pillows

CF-Mesa, CF-Light Mesa, CF-Flute, CF-Metl-Plank, CF-Striated, CF-Santa Fe, CF-Architectural Flat, CF...

Approval Standard for Fume Exhaust Ducts or Fume and Smoke Exhaust Ducts

Approval Standard for Plastic Suspended Ceiling Panels

Approval Standard for Land Mobile Radios for use in Class I, Division 1 Hazardous (Classified) Locations

ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: NORSE, INC.

Class Number May FM Approvals LLC. All rights reserved.

ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT. Rendered to: BEKAERT SPECIALTY FILMS, LLC

The entire document shall be read and understood before proceeding with a test. ISTA 3B Page 1 of 35

Appendix B Florida Building Code Building Section Public Shelter Design Criteria

TEST REPORT. Report No.: A Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept

Protecting Roofing Systems Against Windstorm Damage

PRODUCT CERTIFICATION REQUIREMENTS

Evaluating the Field Performance of Windows and Curtain Walls of Large Buildings

Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls and Sloped Glazing Systems

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

TEST REPORT. Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana

Packaged-Products for Parcel Delivery System Shipment 70 kg (150 lb) or Less

Impact-Resistant Windows and Sliding Glass Doors

SECTION METAL WALL PANELS

FM 4473 TEST REPORT. Rendered to: VTECH INDUSTRIES, LLP. SERIES/MODEL: 4 x 4 CMC Hurricane PRODUCT TYPE: Skylight

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

The Florida Building Code

A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS

How To Test For An Architectural Test

Testing Water Penetration Resistance of Window Systems Exposed to Realistic Dynamic Air Pressures

SFI SPECIFICATION 28.1 EFFECTIVE: SEPTEMBER 23, 2011 *

Wastewater Capital Projects Management Standard Construction Specification

Assessing Curtain Walls

Insurance Mitigation Factors for Homeowners Purchasing Garage Doors In Florida

MOCK-UP TEST REPORT. Rendered to: TUBELITE, INC. PROJECT: 200 Series Curtain Wall Mock-Up

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

Approval Standard for Water Motor Gong

PERFORMANCE TEST REPORT

WATER PENETRATION TESTING OF STUCCO ON CONCRETE MASONRY CONSTRUCTION

Building Code Clarifications - 7. Fire Resistance

CONDENSATION IN REFRIDGERATED BUILDINGS

Chapter 3 Pre-Installation, Foundations and Piers

Informational Bulletin

T H E A A M A C E R T I F I C A T I O N P R O G R A M

Sun Vinyl New Construction Windows Homeowner's Warranty

LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.

Analysis II Façade Redesign: Architectural Precast Panels

STANDARD FOR NON-FIRE RATED ROLLING DOORS

IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION. Generated: Sergiy Papyshev Engineering. Approved: Don Prysi Manufacturing. Approved: Merzuk Ramic Quality

FIELD TESTING SERVICES

DuPont Tyvek Commercial Air Barrier Assemblies Exceed Air Barrier Association of America, ASHRAE 90.1

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

City of San Diego, CWP Guidelines

(800) (562) A Subsidiary of the International Code Council *Revised April 2014

Discipline: Structural Issued

CH. 2 LOADS ON BUILDINGS

Architectural Testing

WATER LEAKAGE IN GLAZED CURTAIN WALL SYSTEMS:

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

Excerpts from the Canadian National Building Code (NBC)

SECTION 1 GENERAL REQUIREMENTS

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER:

Vestibule Case Study. Vestibule Requirement Intent [2003 IECC, 2006 IECC, 2003 IBC, 2006 IBC, , ]

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

Property Policyholder Risk Improvement Report and Hurricane Survey

Florida Building Code, 5th Edition (2014) June 30 th, 2015

Advanced Wind Mitigation Methodologies Pt. 2 Online Retrofit Course. Section 1: Introduction

General Fire Code Requirements Within Commercial Tenant Spaces

ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: Atrium Companies, Inc. SERIES/MODEL: 50/305 HS PRODUCT TYPE: Vinyl Horizontal Slider

EAST LYME HIGH SCHOOL

SFI SPECIFICATION EFFECTIVE: FEBRUARY 26, 2014 *

Know the Code: Using Spray Foam Insulation In Attics and Crawl Spaces

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Report No.: B Rendered to: CAPTIVEAIRE, INC. Blue Bell, Pennsylvania

research highlight Water Penetration Resistance of Windows - Study of Codes, Standards,Testing, and Certification

COMMERCIAL BUILDING APPLICATIONS

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Walking and Working Surface Checklist:

IGNITION-RESISTANT CONSTRUCTION: THE WHY BEHIND THE WHAT

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP

Mario D. Gonçalves, Patenaude-Trempe 1 Pierre Gendron, Patenaude-Trempe 2 Tony Colantonio, PWGSC 3. Abstract

Dubai Municipality Standard DMS 1: Part 5: 2004

Metal Roofing Practical Design

GYPSUM AREA SEPARATION FIREWALLS GA

Windows, skylights, vents, and glazed portions of doors are critical components of a building s

Double Coated Urethane Foam Tapes

Solar America Board for Codes and Standards

If you are a web registered user of ArlingontPermits.com you may also request an inspection at:

Ordering Drums for Hazardous or Non Hazardous Material Transportation

The replacement or modification of existing windows shall comply with the following requirements:

THE DOW CHEMICAL COMPANY Issued: August 1, LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN (989)

2010 edition. Handbook of. Fire-Rated Glass. for schools

Denver Fire Department Idle Pallet Storage Guidelines Per NFPA 13_Chpt 12

2009 IECC Update. Scope. Content. International Energy Conservation Code

National Building Code of Canada 2010

DESIGN OF PRESTRESSED BARRIER CABLE SYSTEMS

C. Section TESTING LABORATORY SERVICE.

Residential Deck Safety, Construction, and Repair

G SPECIFICATION: GAS METER AND REGULATOR INSTALLATION REQUIREMENTS. 3 and Gas Yellow Book. REVISIONS: (See ) 1/15/14 5 Years

REPORT NUMBER: COQ-003 ORIGINAL ISSUE DATE: July 19, 2013

continuing professional education. As such, it construed to be an approval or endorsement by

Control filling, grading, dredging, and other development which may increase erosion or flood damage; and

GreenGuard Housewrap Installation Guide

Asphalt Shingle Application Requirements

Transcription:

Approval Standard for Class 1 Exterior Wall Systems Class Number 4881 November 2007 2007 FM Approvals LLC. All rights reserved.

Foreword The FM Approvals certification mark is intended to verify that the products and services described will meet FM Approvals stated conditions of performance, safety and quality useful to the ends of property conservation. The purpose of Approval Standards is to present the criteria for FM Approval of various types of products and services, as guidance for FM Approvals personnel, manufacturers, users and authorities having jurisdiction. Products submitted for certification by FM Approvals shall demonstrate that they meet the intent of the Approval Standard, and that quality control in manufacturing shall ensure a consistently uniform and reliable product. Approval Standards strive to be performance-oriented. They are intended to facilitate technological development. For examining equipment, materials and services, Approval Standards: a) must be useful to the ends of property conservation by preventing, limiting or not causing damage under the conditions stated by the Approval listing; and b) must be readily identifiable. Continuance of Approval and listing depends on compliance with the Approval Agreement, satisfactory performance in the field, on successful re-examinations of equipment, materials, and services as appropriate, and on periodic follow-up audits of the manufacturing facility. FM Approvals LLC reserves the right in its sole judgment to change or revise its standards, criteria, methods, or procedures.

TABLE OF CONTENTS 1 INTRODUCTION... 1 1.1 Purpose... 1 1.2 Scope... 1 1.3 Basis for Requirements... 2 1.4 Basis for Approval... 2 1.5 Basis for Continued Approval... 3 1.6 Effective Date... 3 1.7 System of Units... 3 1.8 Applicable Documents... 3 1.9 Glossary... 4 2 GENERAL BACKGRUND AND INFORMATION... 5 2.1 General Background... 5 2.2 General Information... 6 2.3 Markings... 6 2.4 Installation Instructions... 7 2.5 Drawings and Specifications... 7 2.6 Other Requirements... 7 3 APPROVAL CATEGORIES AND RATINGS... 7 3.1 Fire Ratings... 7 3.2 Wind Load Ratings... 8 3.3 Hail Resistance Ratings... 9 4 PERFORMANCE REQUIREMENTS... 9 4.1 Class 1 Fire Rating... 9 4.2 Simulated Wind Load Rating... 9 4.3 Windborne Debris Ratings... 11 4.4 Hail Resistance Rating... 12 5 OPERATIONS REQUIREMENTS... 12 5.1 Demonstrated Quality Control Program... 12 5.2 Facilities and Procedures Audits (F&PA)... 13 APPENDIX A: FM Approvals Certification Marks, Usage Guidelines... 14 APPENDIX B: Units of Measurement... 16 APPENDIX C: Structural Test Method for Exterior Wall Systems Exposed to Static Air Pressure Differentials... 17 C-1 Introduction... 17 C-2 Test Apparatus and Arrangement... 17 C-3 Test Specimen... 18 C-4 Test Procedure... 18 C-5 Performance Requirements... 19 APPENDIX D: Structural Test Method for Exterior Wall Systems Exposed to Cyclic Air Pressure Differentials... 20 D-1 Introduction... 20 D-2 Test Apparatus and Arrangement... 20 D-3 Test Specimen... 21 D-4 Test Procedure... 21 D-5 Performance Requirements... 22 APPENDIX E: Test Method for Exterior Wall Systems Impacted by Windborne Debris... 24 E-1 Introduction... 24 E-2 Test Apparatus and Arrangement... 24 E-3 Test Specimen... 25 E-4 Test Procedure... 25 E-5 Performance Requirements... 26

APPENDIX F: Simulated Hail Resistance Test Using Freezer Ice Balls... 27 F-1 Introduction... 27 F-2 Test Apparatus and Arrangement... 27 F-3 Test Specimen... 27 F-4 Test Procedure... 28 F-5 Performance Requirements... 28 APPENDIX FLA: Specification Tested Product Listing for High-Velocity Hurricane Zones in Florida... 29 FLA-I Introduction... 29 FLA-II References... 29 FLA-III Definitions... 30 FLA-IV Test Specimens... 30 FLA-V Testing Application (TAS) 201-94, Impact Test Procedures... 31 FLA-VI Testing Application (TAS) 202-94, Criteria for Testing Impact and Non-Impact Resistant Building Envelope Components Using Uniform Static Air Pressure... 33 FLA-VII Testing Application (TAS) 203-94, Criteria for Testing Products Subject to Cyclic Wind... 34 FLA-VIII Operational Requirements for Specification Tested Products Listed By FM Approvals... 35 FLA-IX Test Reports... 35

November 2007 4881 1 INTRODUCTION 1.1 Purpose 1.1.1 This standard states Approval requirements for Class 1 Exterior Wall Systems. Exterior wall systems are exposed to a number of natural hazards and must reject rain, wind, hail, water infiltration and other deleterious affects caused from everyday exposure to heat, cold, building movement and sunlight. Damage to a building s outer layer compromises its ability to provide the functions it has been designed to deliver. Compromised exterior walls and openings can pave the way for serious damage to the building contents and to the building structure itself due to storms and the long term effects of water and air infiltration. Damage to the building envelope during high wind events such as hurricanes, tropical cyclones or typhoons will produce costly undesirable effects and possible business interruptions. Products that receive Approval recognition have been evaluated to provide assurance that they will perform their intended functions and maintain the integrity of the building envelope for the stated design conditions. 1.1.2 Exterior wall systems are also exposed to fire and must be able to limit fire propagation over and/or through the assembly. Common sources of ignition include, but are not limited to, the potential fire exposure from one or more adjacent buildings or from yard storage. This is particularly important as many potential fire exposures may be on adjacent property where control of the exposure may be outside the influence of the owner of the exposed building. 1.2 Scope 1.2.1 This standard sets performance requirements for exterior wall panels under simulated laboratory conditions. Exterior wall systems are examined for their ability to limit fire propagation over and/or through the assembly when exposed to an ignition source simulating a building fire (see Approval Standard 4880, Class 1 Fire Rating of Insulated Wall or Wall & Roof/Ceiling Panels; Interior Finish Materials, or Coatings, and Exterior Wall Systems (2005) for a complete description of the fire test requirements). This standard also sets the performance requirements for exterior wall panels when exposed to various natural hazards such as the cyclic nature of wind in high wind events, the impact of simulated hail and where required, the impact of windborne debris during hurricanes, tropical cyclones and typhoons. 1.2.2 FM Approved wall panels, for interior and/or exterior use, shall be examined for their ability to limit fire spread using Approval Standard 4880. Exterior wall systems shall also be examined for various natural hazards as detailed in this standard. 1.2.3 Systems that are intended solely for use as interior walls systems shall be qualified in accordance with Approval Standard 4880. 1.2.4 This standard is intended to qualify many types of exterior wall systems including, but not limited to metal, concrete, composite and glass. 1.2.5 This standard is not intended to qualify fenestration products such as doors, windows and storm shutters or other exterior insulated finish systems (EIFS), or other exterior wall coating systems. This standard does not address quality of workmanship or ease of or need for maintenance. 1.2.6 This standard is not intended to determine the suitability for all end use conditions of a product. Conditions under which exterior wall systems are used vary widely. It is the responsibility of the manufacturer and building owner to determine the suitability of the exterior wall system for the intended location. 1.2.7 One of the more critical natural hazards that a building is exposed to is rain. The issue of water damage to a building is a major concern. FM Approvals recognizes the importance of exterior wall systems in preventing water infiltration and the resulting damage. FM APPROVALS 1

4881 November 2007 1.2.7.1 Popular opinion is that most water damage to exterior wall systems is caused by repeated exposure to rain and moisture over long periods of time as opposed to short periods of intense exposure during a single storm. In addition to the intensity of rainfall and the material used to form the exterior of the system, the ability of the entire system to prevent water infiltration is also a function of the performance of the materials used for jointing and sealing purposes as well as the systems resistance to ultraviolet light, heat, aging, building movement and repeated freeze/thaw. 1.2.7.2 A review of the existing test methods currently in the public domain was conducted. None were incorporated into this standard at this time as they were deemed to be inadequate for the purpose of this standard. It is the intention of FM Approvals to conduct research on this topic in the future. At that time, the standard may be revised to incorporate other test methods and criteria deemed necessary to adequately address water infiltration. 1.2.8 In an effort to assist customers of FM Approvals in qualifying their products for use in the State of Florida while obtaining Approval, manufacturers can use Appendix FLA to obtain a listing by FM Approvals as a Specification Tested Product that can be used to also satisfy the performance criteria required by the Test Protocols for High-Velocity Hurricane Zones in Florida. 1.3 Basis for Requirements 1.3.1 The requirements of this standard are based on experience, research and testing and/or the standards of FM Approvals and other organizations. The advice of manufacturers, users, trade associations and loss control specialists was also considered. 1.3.2 Meeting these requirements qualifies a product as an FM Approved exterior wall system. Requirements prohibit component substitution without prior authorization by FM Approvals. 1.3.3 The requirements of this standard reflect tests and practices used to examine characteristics of exterior wall systems for the purpose of obtaining Approval. These requirements are intended primarily as guides and strict conformity is not always mandatory. Exterior wall systems having characteristics not anticipated by this standard may be FM Approved if performance equal or superior to that required by this standard is demonstrated, or if the intent of the standard is met. Alternatively, exterior wall systems that meet all the requirements identified in this standard may not be FM Approved if other conditions that adversely affect performance exist or if the intent of this standard is not met. 1.4 Basis for Approval Approval is based upon satisfactory evaluation of the product and the manufacturer in the following major areas: 1.4.1 Examination and tests on production samples to evaluate the suitability of the product; the proper performance of the product as specified by the manufacturer and as demonstrated when examined in accordance with this standard; the durability and reliability of the product. 1.4.2 Examination of the manufacturing facilities and audit of quality control procedures to evaluate the manufacturer s ability to consistently produce the product as examined and tested, and the marking procedures used to identify the product. These examinations are repeated as part of the FM Approvals follow-up Facilities and Procedures Audit program. 2 FM APPROVALS

November 2007 4881 1.5 Basis for Continued Approval Continued Approval is based upon: production or availability of the product as FM Approved; the continued use of acceptable quality control procedures; satisfactory field experience; compliance with the terms stipulated in the Agreements of FM Approvals; and re-examination, if deemed necessary, of production samples for continued conformity to requirements. 1.6 Effective Date 1.6.1 The effective date of an Approval Standard mandates that all products tested for Approval after the effective date shall satisfy the requirements of that standard. Products FM Approved under a previous edition shall comply with the new version by the effective date or else forfeit Approval. The effective date shall apply to the entire Approval Standard, or, where so indicated, only to specific paragraphs of the standard. 1.6.2 The effective date for this standard is January 1, 2006 for compliance with all requirements. 1.6.3 The effective date for compliance with all requirements relating to water infiltration has not been determined (see Paragraph 1.2.6). 1.6.4 The effective date for compliance for Appendix FLA shall be November 1, 2007. 1.7 System of Units Units of measurement are U.S. customary units. These are followed by their arithmetic equivalents in International System (SI) units, enclosed in parentheses. Appendix B lists the selected units for qualities dealt with in testing these products; conversions to SI units are included. Conversion of U.S. customary units is in accordance with ANSI/IEEE/ASTM SI 10-97, Standard for Use of the International System of Units (SI): The Modern Metric System. 1.8 Applicable Documents The following are standards, test methods and practices referenced in this standard: American Society for Testing and Materials (ASTM) International ASTM E 283-04, Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen ASTM E 330-02, Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference ASTM E 1233-00, Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls and Doors by Cyclic Static Air Pressure Differential ASTM E 1886-02, Standard Test Method for Performance of Exterior Windows, Curtain Walls, Doors and Storm Shutters Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials ASTM E 1996-03, Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors and Storm Shutters Impacted by Windborne Debris in Hurricanes FM APPROVALS 3

4881 November 2007 FM Approvals/FM Global Approval Standard 4470, Class 1 Roof Covers (1986 with addenda) Approval Standard 4880, Class 1 Fire Rating of Insulated Wall or Wall & Roof/Ceiling Panels; Interior Finish Materials or Coatings; and Exterior Wall Systems (2005) Test Standard 4473, Specification Test Protocol for Impact Resistance Testing of Rigid Roofing Materials by Impacting with Freezer Ice Balls (February 2000) Structural Test Method for Exterior Wall Systems Exposed to Static Air Pressure Differentials (Appendix C) Structural Test Method for Exterior Wall Systems Exposed to Cyclic Air Pressure Differentials (Appendix D) Test Method for Exterior Wall Systems Impacted by Windborne Debris (Appendix E) Simulated Hail Resistance Test Using Freezer Ice Balls. (Appendix F) FM Global Property Loss Prevention Data Sheet 1-28, Design Wind Loads (January 2002) FM Global Property Loss Prevention Data Sheet 1-29, Roof Deck Securement and Above-Deck Roof Components (September 2003) Building Codes 2004 Florida Building Code Testing Application Standard (TAS) 201-94, Impact Test Procedures Testing Application Standard (TAS) 202-94, Criteria for Testing Impact and Non-Impact Resistant Building Envelope Components Using Uniform Static Air Pressures Testing Application Standard (TAS) 203-94, Criteria for Testing Products to Cyclic Wind Pressure Loading International Building Code SSTD 12-99, Standard for Determining Impact Resistance for Windborne Debris 1.9 Glossary Class 1 signifies that the material meets FM Approvals test requirements as a non-fire propagating material. Such materials do not require sprinkler protection in and of themselves when used in accordance with FM Global Property Loss Prevention Data Sheets. Class 1 Exterior Wall System an exterior wall system that meets the requirements of this standard for fire, wind, impact from hail, corrosion (if applicable) and missile impact from windborne debris, where applicable. Exterior Wall System an assemblage of materials that form the outer protective layer of a building. Inward Wind Pressure a condition created on the windward side of a building. It is caused by wind forces and places forces toward the wall. It is referred to by some entities as positive pressure. Outward Wind Pressure a condition created on the leeward side of a building. It is caused by wind forces and places forces away from the wall. It is referred to by some entities as negative pressure. 4 FM APPROVALS

November 2007 4881 Pressure Coefficient a factor accounting for variations in inward and outward wind pressure on walls at different locations and elevations of the same building. Windborne Debris objects and pieces of broken materials that have become airborne projectiles due to the high winds caused by hurricanes, tropical cyclones and typhoons. 2 GENERAL BACKGROUND AND INFORMATION 2.1 General Background 2.1.1 The selection of an exterior wall system is a critical component in the overall effectiveness of a building s ability to perform the functions for which it has been designed. It is the first line of defense in combating the effects of natural hazards and protecting the lives of those in or near the building as well as the contents of the building. The system selected must be durable, cost effective and aesthetically pleasing. It must be able to withstand the design conditions that will be placed on the system from internal sources for which it has been constructed as well as natural external sources such as rain, wind and hail. Selection of a system that has not demonstrated that it can withstand the design conditions over long periods of time can lead to a loss of life or property as well as a loss of business. 2.1.2 Design conditions vary widely throughout the world. The selection of an exterior wall system should be based, in part, on the geographical location where it will be constructed, its surroundings as well as the historical meteorological events that have occurred and are likely to occur in the future. 2.1.3 Anticipated design conditions at a particular geographic location vary depending on the intensity of the event, the surrounding terrain and elevation. Components on the windward side of a building are subjected to design wind pressures [P inward ] which increase as the elevation of the building increases. Pressures on the leeward side [P outward ] of a building can reach twice the wind pressure normally found on the windward face of the building at the same elevation but acting in the opposite direction. Approval ratings will show both inward (+) and outward (-) pressures for which the system has been successfully tested. In an effort to allow for economic building construction, Approval will be granted for two ratios of inward and outward pressure. The ratio of the inward and outward pressures shall be (+)1.0 to (-)1.4 or (+)1.0 to (-)2.0. 2.1.4 In an effort to allow for economic building construction, in addition to the wind load ratings shown above, Approval categories have been developed for the most common windstorm zones likely to be encountered. These zones, as explained in Paragraph 3.2.3, shall be designated as Zones HM, H and NH. The zones have been established to Approve products intended for use in areas that require protection against a) hurricane force winds and missile impacts resulting from windborne debris (HM), b) hurricane force winds only (H) and c) non-hurricane areas (NH) that do not require either a) or b). 2.1.5 Exterior wall systems that meet the requirements of this Approval Standard will maintain the integrity of the building envelope for the stated design conditions. While the performance requirements contained in this Approval Standard would indicate that FM Approved exterior wall systems will not suffer permanent deformation or physical damage after windstorms or hail storms, the systems should be examined after each storm for damage that could adversely affect its performance in future storms. FM APPROVALS 5

4881 November 2007 2.1.5.1 In the case where a system has been FM Approved for use in areas prone to hurricane force winds and the missile impacts from windborne debris, the system may sustain permanent physical damage. As such, the systems should be examined after each storm for damage that could adversely affect its performance in future storms. Repairs should be made as soon as possible to any damaged areas. 2.1.5.2 Because the acceptance criteria for systems impacted by windborne debris vary throughout the country, two (2) levels of both large and small missile Approval have been created (see Paragraph 3.2.2). This will assist manufacturers and end users in determining if the system will meet local codes requirements and FM Global Data Sheet recommendations. 2.2 General Information 2.2.1 The requirements of this standard shall be used to measure and describe the performance of exterior wall systems to simulated fire, wind loads and hail impact under controlled laboratory conditions. 2.2.2 The performance of exterior wall systems can be greatly affected by the quality of the workmanship and the long term affects of water infiltration, exposure to sunlight, heat, building movement and the normal aging process. These items have not been considered in developing the test methods included in this standard. 2.2.3 A particular wall system may be designed for interior use only, exterior use only or for both interior and exterior use. In all cases they shall be examined for their ability to limit fire propagation over and/or through the assembly when exposed to an ignition source simulating a building fire. All such fire tests shall be conducted in accordance with Approval Standard 4880. 2.2.3.1 Wall systems designed for both interior and exterior use can be qualified by a single fire test as noted in 2.2.3 if a) the wall panels are not symmetrical and FM Approvals can determine the most critical side to be tested based on engineering judgment or b) the wall is symmetrical and incorporates a fire barrier such as gypsum board. 2.2.3.2 This standard is not applicable to wall systems designed solely for interior use. Such systems shall be examined in accordance with Approval Standard 4880. 2.3 Markings 2.3.1 The packaging for exterior wall systems shall bear the manufacturer s name, product trade name and the Approval mark of FM Approvals (see Appendix A). 2.3.2 Each FM Approved exterior wall system shall also bear the Approval marking, where practicable, on components that consist of long sections. Such markings shall be permitted to be located on the backside of the component such that it can not be seen after it has been installed. 2.3.3 Upon completion of an installation, the manufacturer shall attach permanent, corrosion resistant nameplates to the exterior of the building. The nameplates shall be visible from ground level. At a minimum, the nameplates shall bear the manufacturer s name, product trade name, date of construction, the Approval mark of FM Approvals and the applicable Approval ratings for fire, wind and hail. 2.3.4 With the exception of the nameplates installed on the exterior of the building after the completion of an installation, labels or markings denoting Approval shall be applied by the manufacturer only within and on the premises of manufacturing locations that are under the FM Approvals Facilities and Procedures Audit Program. 6 FM APPROVALS

November 2007 4881 2.3.5 Products that meet the criteria contained in Appendix FLA shall be designated as Specification Tested Products. Details for the markings associated with this type of recognition shall be in accordance with Appendix FLA. 2.4 Installation Instructions 2.4.1 The manufacturer shall make every reasonable effort to supply all necessary instructions and other assistance to the installer to ensure proper installation. Printed application instructions shall be provided by the manufacturer to demonstrate proper installation procedures. As part of the Approval examination, and at the discretion of FM Approvals, at least one inspection of a field installation during and/or after completion may be required. In some cases, a continued program of inspections shall be necessary to assess the application procedures or changes within the application techniques. 2.4.2 The manufacturer shall supply written information to the installer detailing the specific installation requirements as contained in FM Global Property Loss Prevention Data Sheets and other pertinent FM Global or FM Approvals standards. 2.5 Drawings and Specifications The manufacturer shall provide FM Approvals with complete system drawings and raw material specifications, including proprietary formulation(s), if applicable. Further, the manufacturer shall notify FM Approvals of any change in the manufacturing procedures or materials used in the FM Approved components prior to general sale and distribution. 2.6 Other Requirements All samples submitted for testing shall be representative of production run material. FM Approved exterior wall systems shall be manufactured with the identical raw materials and fabrication techniques as originally tested. The specifications shall be kept on file at FM Approvals. 3 APPROVAL CATEGORIES AND RATINGS 3.1 Fire Ratings All FM Approved exterior wall systems shall attain a Class 1 rating in accordance with Approval Standard 4880. Class 1 exterior wall systems may be rated for use to unlimited heights, for use to a maximum height of 50 ft (15.2 m) or to a maximum height of 30 ft (9.1 m). See Section 5 of Approval Standard 4880 for the required tests and performance requirements to obtain these ratings. FM APPROVALS 7

4881 November 2007 3.2 Wind Load Ratings 3.2.1 All FM Approved Class 1 exterior wall assemblies shall have a wind load rating. The rating shall be expressed as a pair of inward and outward acting pressures (P inward and P outward ) using a static pressure test and a cyclic pressure test. The FM Approved rating shall be the lowest pair of pressures (inward and outward) from the static pressure test or the cyclic pressure test. The ratings shall be given in increments of 5 lbs/ft 2 (0.25 kpa) based on the inward pressure. The minimum rating needed for Approval shall be 30 lbs/ft 2 (1.45 kpa) for the inward pressure. 3.2.1.1 The magnitude of the pressure on the leeward side is equal or higher than the pressure on the windward side. Because of this, the outward pressure used in the test program shall be of greater magnitude than the inward pressure. The FM Approved outward pressure will be based on pressure coefficients of either (-1.4P) or (-2.0P) based on an applied pressure (+P) on the windward side. The positive sign is used to signify the fact that P inward applies forces toward the wall. The negative sign is used to signify that P outward places forces away from the wall (suction). Examples of possible wind load ratings are +30 lbs/ft 2, -42 lbs/ft 2 (+1.45 kpa, -2.0 kpa) or +40 lbs/ft 2, -80 lbs/ft 2 (+1.9 kpa, -3.8 kpa). The test sponsor shall determine the pressure coefficient used in the test program. FM Global Property Loss Prevention Data Sheet 1-28 shall be used to determine the minimum wind load rating(s) needed based on the building s geometry and geographic location. 3.2.2 As an option, the test sponsor may choose to qualify their exterior wall system for windborne debris (missile impact) resistance. Two categories of impact resistance are available large missile or small missile. The large missile test shall consist of a series of impacts using an 8 ft (2.4 m) long nominal wooden 2 4 weighing 9 lbs (4 kg) traveling at a speed of 50 ft/sec (15.25 m/s). This speed is approximately 35 miles/hr (56 km/hr). The small missile test shall consist of a series of impacts with each impact consisting of ten (10) steel balls with each steel ball weighing 0.07 oz (2 g) traveling at a speed of 130 ft/sec (39.6 m/s). This speed is approximately 90 miles/hr (145 km/hr). 3.2.2.1 The Approval designation for the large or small missile impact resistance rating shall be categorized by the suffix LM (large missile impact resistance) or SM (small impact missile resistance) to denote the level of missile impact resistance. 3.2.2.2 Within each category of missile impact resistance, there shall be two (2) levels of Approval. The level of Approval shall be based on the acceptance criteria used. The first level of Approval is based on the International Building Code (IBC). The second level of Approval is based on the acceptance criteria of the Florida Building Code (FBC). This distinction is being made as the acceptance criteria for the FBC is more stringent than the acceptance criteria for other parts of the country. The main difference is that the IBC acceptance criteria allows for the development of small through openings which may be acceptable in some cases whereas the FBC does not allow the missile to penetrate the building component being tested. When the second level of Approval is obtained, the connotation (FL) shall be shown after the category of missile impact resistance. For example, an exterior wall panel that meets the large missile impact resistance using the first level (IBC) of Approval criteria would be shown as Wind Zone HM LM (see Paragraph 3.2.3 for Wind Zone Designations). An exterior wall panel that meets the small missile impact resistance using the second level (FBC) of Approval criteria would be shown as Wind Zone HM SM (FL). 3.2.3 FM Approvals recognizes three (3) different wind zone categories. These Approval categories shall be referred to as Zone HM, Zone H and Zone NH. The FM Global Property Loss Prevention Data Sheets shall be used to determine which zone applies for a particular location. 3.2.3.1 Zone HM shall be used to denote those exterior wall assemblies that have been qualified for locations that are subject to both hurricane force winds and missile impact from windborne debris. The ratings shall be determined from static and cyclic pressure tests and the missile impact test(s). Such assemblies may meet the requirements of either the large missile or the small missile impact test. 8 FM APPROVALS

November 2007 4881 3.2.3.2 Zone H shall be used to denote those exterior wall assemblies that have been qualified for locations that are subject to hurricane force winds but not subject to missile impacts from windborne debris. The ratings shall be determined from static and cyclic pressure tests. 3.2.3.3 Zone NH shall be used to denote those exterior wall assemblies in non-hurricane zones that are not subjected to either hurricane force winds or missile impacts from windborne debris. The ratings shall be determined from static and cyclic pressure tests. 3.3 Hail Resistance Ratings 3.3.1 All FM Approved Class 1 exterior wall assemblies shall have a Hail Resistance Rating. This rating simulates the expected impact of hail. The ratings available are Severe and Moderate. These values are consistent with corresponding ratings and impact energies used in Approval Standard 4470, Class 1 Roof Covers. FM Global Loss Prevention Data Sheet 1-29 shall be used to determine the impact (hail) rating needed for a particular geographic location. 4 PERFORMANCE REQUIREMENTS 4.1 Class 1 Fire Rating 4.1.1 Requirement In order to qualify as an FM Approved Class 1 Exterior Wall System, the candidate system shall exhibit limited combustibility when examined in accordance with Approval Standard 4880. If a wall system or wall panel can be used for both interior and exterior use, only one (1) set of fire tests shall be conducted provided that a) it can be determined the most critical side to test or b) the wall system is symmetrical and incorporates some type of fire barrier such as gypsum board. 4.1.2 Test/Verification Depending on the particular Class 1 rating desired [unlimited height, maximum 50 ft (15.2 m) in height or maximum of 30 ft (9.1 m) in height], the examination may include a Flammability Characterization, the FM Approvals 25 ft (7.6 m) High Corner Test, the FM Approvals 50 ft (15.2 m) High Corner Test, a Room Test, a Surface Burning Characteristics Test, a Density Test, an Ignition Property Test, a Heat Content Test and an Ash Content Test. For details of the actual tests and acceptance criteria, see Approval Standard 4880. 4.2 Simulated Wind Load Rating 4.2.1 Structural Test Method for Exterior Wall Systems Exposed to Static Air Pressure Differentials A. Requirement In order to qualify as an FM Approved Class 1 Exterior Wall System, all systems shall be tested in accordance with the Structural Test Method for Exterior Wall Systems Exposed to Static Air Pressure Differentials (Appendix C). This test method consists of sealing the test specimen into or against one face of a test chamber, supplying air to or exhausting air from the chamber according to a specific test loading program at the rate required to maintain the test pressure difference across the specimen, and observing, FM APPROVALS 9

4881 November 2007 measuring and recording the nature of any distress or failure of the specimen. The inward pressure level, P inward, that is used during the test, shall be at the discretion of the test sponsor. The tests shall be conducted such that the ratio of the outward pressure to the inward pressure (P outward /P inward ) shall be either (-1.4) or (-2.0). B. Test/Verification One (1) sample shall be tested per the Structural Test Method for Exterior Wall Systems Exposed to Static Air Pressure Differentials (Appendix C). This sample is not required to be subjected to any other tests as part of a test program. Upon completion of the test, the sample shall show no signs of cracking or any other signs of failure. The sample shall be permitted to be reused for other tests in this program or to be retested at higher pressures in order to obtain a higher wind rating. 4.2.2 Structural Test Method for Exterior Wall Systems Exposed to Cyclic Air Pressure Differentials (Procedure A) A. Requirement In order to qualify as an FM Approved Class 1 Exterior Wall System, all systems shall be tested in accordance with the Structural Test Method for Exterior Wall Systems Exposed to Cyclic Air Pressure Differentials (Appendix D). Systems that are intended for use in areas subject to hurricane force winds (Zones HM and H) shall be examined in accordance with Procedure A of this test method. Systems that are intended for use in areas that are not subject to hurricane force winds (Zone NH) shall be examined in accordance with Procedure B. This test method consists of sealing the test specimen into or against one face of a test chamber, supplying air to or exhausting air from the chamber according to a specific test loading program (a total of 9000 cycles) at various pressure levels across the specimen, and observing, measuring and recording the nature of any distress or failure of the specimen. The inward pressure level, P inward that is used during the test shall be at the discretion of the test sponsor. The tests shall be conducted such that the ratio of the outward pressure to the inward pressure (P outward /P inward ) shall be either (-1.4) or (-2.0). B. Test/Verification The exterior wall assembly shall be tested per the Structural Test Method for Exterior Wall Systems Exposed to Cyclic Air Pressure Differentials (Appendix D). Samples intended for use in Zone H are not required to be subjected to any other tests prior to or subsequent to this test. Samples intended for use in Zone HM shall be impacted by either the large missiles or small missiles (windborne debris) in accordance with the Test Method for Exterior Wall Systems Impacted by Windborne Debris (Appendix E) prior to being subjected to this test. For systems intended for use in Zone H, one (1) sample shall be tested in accordance with Procedure A. Upon completion of the test, the sample shall show no signs of cracking or any other signs of failure. For systems intended for use in Zone HM, see the acceptance criteria for the Test Method for Exterior Wall Systems Impacted by Windborne Debris (Paragraph 4.3.1). All three (3) samples that are impacted for windborne debris shall be subjected to the Structural Test Method for Exterior Wall Systems Exposed to Cyclic Air Pressure Differentials, Procedure A. Upon completion of the Structural Test Method for Exterior Wall Systems Exposed to Cyclic Air Pressure Differentials test, each sample shall continue to meet the acceptance criteria for the Test Method for Exterior Wall Systems Impacted by Windborne Debris (see Paragraph 4.3.1). Systems FM Approved for use in Zone HM shall also have one (1) additional sample examined in accordance with the Structural Test Method for Exterior Wall Systems Exposed to Cyclic Air Pressure Differentials, Procedure A. This sample shall not be impacted by simulated windborne debris. Upon completion of the test, the sample shall show no signs of cracking or any other signs of failure. Systems intended for use in Zone NH shall be tested in accordance with the Structural Test Method for Exterior Wall Systems Exposed to Cyclic Air Pressure Differentials, Procedure B. 10 FM APPROVALS

November 2007 4881 4.2.3 Structural Test Method for Exterior Wall Systems Exposed to Cyclic Air Pressure Differentials (Procedure B) A. Requirement In order to qualify as an FM Approved Class 1 Exterior Wall System, all systems shall be tested in accordance with the Structural Test Method for Exterior Wall Systems Exposed to Cyclic Air Pressure Differentials. This test method (Procedure B) is intended only for use in areas not prone to hurricane force winds (Zone NH). Systems that are intended for use in areas that are prone to hurricane force winds (Zone HM and H) shall be examined in accordance with Procedure A as shown in Paragraph 4.2.2. This test method consists of sealing the test specimen into or against one face of a test chamber, supplying air to or exhausting air from the chamber according to a specific test loading program (a total of 1056 cycles) at various pressure levels across the specimen, and observing, measuring and recording the nature of any distress or failure of the specimen. The inward pressure level, P inward, that is used during the test shall be at the discretion of the test sponsor. The tests shall be conducted such that the ratio of the outward pressure to the inward pressure (P outward /P inward ) shall be either (-1.4) or (-2.0). B. Test/Verification The exterior wall assembly shall be tested per the Structural Test Method for Exterior Wall Systems Exposed to Cyclic Air Pressure Differentials, Procedure B (Appendix D). Samples intended for use in Zone NH are not required to be subjected to any other tests prior to or subsequent to this test. For systems intended for use in Zone NH, one (1) sample shall be tested. Upon completion of the test, the sample shall show no signs of cracking or any other signs of failure. 4.3 Windborne Debris Ratings 4.3.1 Test Method for Exterior Wall Systems Impacted by Windborne Debris A. Requirement In order to qualify as an FM Approved Class 1 Exterior Wall System for use in Zone HM, the system shall be tested for either Large Missile or Small Missile Impact Resistance in accordance with the Test Method for Exterior Wall Systems Impacted by Windborne Debris (Appendix E). These systems are intended for use in areas prone to hurricane force winds and where windborne debris resistance is required. The large missile impact test consists of impacting a test specimen with a series of impacts. The large missile is an 8 ft (2.4 m) long nominal wooden 2 4 weighing 9 lbs (4 kg) traveling at a speed of 50 ft/sec (15.25 m/s). This speed is approximately 35 miles per hour (56 km/hr). Each sample shall be subjected to two (2) impacts at predetermined locations. The small missile impact test consists of impacting a test specimen with a series of impacts. Each impact of the small missile consists of ten (10) steel balls with each steel ball weighing 0.07 oz (2 g) traveling at a speed of 130 ft/sec (39.6 m/s). This speed is approximately 90 miles per hour (145 km/hr). Each sample shall be subjected to three (3) sets of impacts at predetermined locations. Subsequent to the missile impact test, either large or small missile, the specimen shall be subjected to Structural Test Method for Exterior Wall Systems Exposed to Cyclic Air Pressure Differentials (Procedure A). The inward pressure level, P inward, that is used during the test shall be at the discretion of the test sponsor. The tests shall be conducted such that the ratio of the outward pressure to the inward pressure (P outward /P inward ) shall be either (-1.4) or (-2.0). FM APPROVALS 11

4881 November 2007 B. Test/Verification Three (3) separate samples shall be tested per the Test Method for Exterior Wall Systems Impacted by Windborne Debris (Appendix E) for either Large Missile or Small Missile Impact Resistance. Following the Test Method for Exterior Wall Systems Impacted by Windborne Debris, each sample shall also be subjected to the Structural Test Method for Exterior Wall Systems Exposed to Cyclic Air Pressure Differentials (Procedure A). To obtain Approval for either Large Missile Impact Resistance [Wind Zone HM-LM] or Small Missile Impact Resistance [Wind Zone HM-SM], upon completion of the cyclic pressure test (which follows the impact test), all three (3) samples shall not develop any openings more than 5 in. (125 mm) in length or any through openings through which a 3 in. (75 mm) diameter solid sphere can freely pass. To obtain Approval for either Large Missile Impact Resistance [Wind Zone HM-LM (FL)] or Small Missile Impact Resistance [Wind Zone HM-SM (FL)], upon completion of the cyclic pressure test (which follows the impact test), all three (3) samples shall have no penetration of the impact protective system by the missile (for the impact test) and during the cyclic test, shall not develop any openings more than 5 in. (125 mm) in length or 1/16 in. (1.6 mm) in width through which air can pass. 4.4 Hail Resistance Rating 4.4.1 Simulated Hail Resistance Test Using Freezer Ice Balls A. Requirement All FM Approved Class 1 Exterior Wall Systems shall be subjected to a simulated hail impact test in accordance with the Simulated Hail Resistance Test Using Freezer Ice Balls (Appendix F). Two (2) ratings are available: Severe (S) and Moderate (M). The test is based on FM Approvals Test Standard 4473, Specification Test Protocol for Impact Resistance Testing of Rigid Roofing Materials Impacted with Freezer Ice Balls with some variations. The Severe Hail rating will consist of a nominal 1.75 in. (44 mm) diameter ice ball having a kinetic energy of 14.9 ft-lbs (20.3 J). The Moderate Hail rating shall consist of a nominal 1.5 in. (38 mm) diameter ice ball having a kinetic energy of 7.8 ft-lbs (10.4 J). B. Verification/Test One (1) test specimen shall be subjected to either the Severe or Moderate impact energy in accordance with the Simulated Hail Resistance Test Using Freezer Ice Balls (Appendix F). Each sample shall be impacted ten (10) times with six (6) of the impacts occurring within 3 in. (75 mm) of the edges of the sample. The specimen shall be considered to meet the test criteria if there is no sign of cracking or splitting. 5 OPERATIONS REQUIREMENTS 5.1 Demonstrated Quality Control Program 5.1.1 A Quality Control Program is required to assure that subsequent Class 1 Exterior Wall Systems produced by the manufacturer shall present the same quality and reliability as the specific sample(s) examined. Design quality, conformance to design and performance are the areas of primary concern. Design quality is determined during the examination and tests. 12 FM APPROVALS

November 2007 4881 Conformance to design is verified by control of quality in the following areas: existence of corporate quality control guidelines incoming assurance, including testing in-process assurance, including testing final inspection and tests equipment calibration drawing and change control packaging and shipping handling and disposition of discrepant materials Quality of performance shall be determined by field performance and by periodic re-examination and test. 5.1.2 The manufacturer shall establish a system of product configuration control to prevent unauthorized changes, including as appropriate: engineering drawings engineering change requests engineering orders change notices These shall be executed in conformance with a written policy and detailed procedures. Records of all revisions to all FM Approved products shall be kept. 5.1.3 The manufacturer shall assign an appropriate person or group to be responsible for obtaining FM Approvals authorization of all changes anticipated to FM Approved products. FM Approvals Form 797, FM Approved Product Revision Report or Address/Contact Change Notice, shall be used to notify FM Approvals of pending changes. Any such changes shall be submitted prior to fabrication and/or distribution, and shall be agreed to in writing by FM Approvals. 5.2 Facilities and Procedures Audits (F&PA) 5.2.1 Inspection of the product manufacturing facility shall be part of the Approval investigation. Its purpose shall be to determine that equipment, procedures, and the manufacturer s quality controls are properly maintained to produce a product of the same quality, construction and formulation as initially tested. 5.2.2 Unannounced follow-up inspections are conducted to assure continued quality control and product uniformity. FM APPROVALS 13

4881 November 2007 APPENDIX A FM Approvals Certification Marks FM Approvals certifications marks are to be used only in conjunction with products or services that have been Approved by FM Approvals and in adherence with usage guidelines. FM APPROVED mark: Authorized by FM Approvals as a certification mark for any product that has been FM Approved. There is no minimum size requirement for the mark, but it must be large enough to be readily identifiable. The mark should be produced in black on a light background, or in reverse on a dark background. Cast-On FM Approvals marks: Where reproduction of the FM Approved mark described above is impossible because of production restrictions, use these modified versions of the FM Approved mark. There is no minimum size requirement for the mark, but it must be large enough to be readily identifiable. FM Approved Mark with C only: Authorized by FM Approvals as a certification mark for any product that has been evaluated by FM Approvals in accordance with Canadian codes and standards. There is no minimum size requirement for the mark, but it must be large enough to be readily identifiable. The mark should be produced in black on a light background, or in reverse on a dark background. FM Approved mark with C and US : Authorized by FM Approvals as a certification mark for any product that has been evaluated by FM Approvals in accordance with US and Canadian codes and standards. There is no minimum size requirement for the mark, but it must be large enough to be readily identifiable. The mark should be produced in black on a light background, or in reverse on a dark background. 14 FM APPROVALS

November 2007 4881 FM Approvals Certification Marks Usage Guidelines All FM Approvals certification marks are the sole property of FM Approvals LLC ( FM Approvals ) and are registered or the subject of applications for registration in the United States and many other countries. They are for use only according to these guidelines. FM Approvals certification marks may be used only on FM Approved products and related product packaging, in advertising material, catalogs and news releases. Use of FM Approvals certification marks on such material is not a substitute for use of the complete FM Approvals certification mark on FM Approved products and/or product packaging. No FM Approvals certification mark or aspect thereof may be incorporated as part of a business name, Internet domain name, or brand name/ trademark for products/product lines. This includes both design aspects (the FM Approvals diamond, etc.) and word aspects ( FM, Approved, etc.). The use of any FM Approvals certification mark as a trademark is strictly prohibited. The Approval Standard number or class number may not be incorporated as part of a business name, Internet domain name, or brand name/ trademark for products/product lines. For example, a company may not say ABC Company s 4100 Fire Door is FM Approved ; the proper terminology is, ABC Company s Fire Door is FM Approved per Approval Standard 4100. FM Approvals certification marks, except for the FM Approvals Quality System Registration mark, may not be used on business stationery/cards/ signage because this could mischaracterize the relationship with FM Approvals. Additionally, these items should not reference any FM Approvals certification mark. Products or services may not be marketed under any mark or name similar to FM Global, FM Approvals or any of the FM Approvals certification marks. Further, products or services may not be marketed to imply a relationship beyond the scope of any Approval made by FM Approvals. When an FM Approvals certification mark is used in advertising material or on product packaging, all material must reflect the specific circumstances under which the product was FM Approved. The material must clearly differentiate between products that are FM Approved and those that are not, and may not, in any way, imply a more substantial relationship with FM Approvals. A company may not reference the intent to submit a product for Approval or the expectation that a company will have a certain product FM Approved in the future. For example, a company may not state, Approval by FM Approvals pending or Approval by FM Approvals applied for. FM Approvals certification marks should not be preceded or followed by a qualifier that indicates a degree of certification or acceptability. For example, exceeds, first or only may not be used to qualify any FM Approvals certification mark. Only original artwork issued by FM Approvals should be used. The FM Approvals certification marks should not be altered in any way other than to resize the artwork proportionately. Unacceptable uses of the marks include, but are not limited to, adding/deleting wording or artwork, reducing the artwork to an illegible size, animation or distortion. The text of the FM Approvals certification marks may not be translated into any language other than English. FM Approvals certification marks must appear in a size and location that is readily identifiable, but less prominent than the name of the owner of the certification or the manufacturer/seller/distributor of the certified products. FM APPROVALS 15

4881 November 2007 APPENDIX B Units of Measurement AREA: in 2 - square inches ; (mm 2 - square millimeters ) mm 2 =in 2 6.4516 10 2 ft 2 square feet ;(m 2 - square meters ) m 2 =ft 2 0.0929 ENERGY: FORCE: LENGTH: ft-lbs foot pounds (J joules ) J = ft-lbs 1.36 lbf pound-force ;(N Newtons ) N = lbf 4.448 in - inches ; (mm - millimeters ) mm = in. 25.4 ft - feet ;(m- meters ) m=ft 0.3048 MASS: PRESSURE: lb - pounds ; (kg - kilograms ) kg=lb 0.454 lbs/in 2 pounds per square inch ; (kpa kilopascals ) kpa = lbs/in 2 6.895 bar bar ; (kpa kilopascals ) bar = kpa 0.01 bar = lbs/in 2 0.06895 TEMPERATURE: VELOCITY: F - degrees Fahrenheit ;( C - degrees Celsius ) C =( F - 32) 0.556 ft/sec feet per second ; (m/sec meters per second ) m/sec = ft/sec 0.3048 miles/hr miles per hour ; (km/hr kilometers per hour ) km/hr = miles/hr 1.61 VOLUME: ft 3 cubic feet ;(m 3 cubic meters ) m 3 =ft 3 0.028 16 FM APPROVALS

November 2007 4881 APPENDIX C Structural Test Method for Exterior Wall Systems Exposed to Static Air Pressure Differentials C-1 Introduction C-1.1 This test method is intended to evaluate the structural performance of exterior wall systems. It is based on ASTM E330-02 with several modifications incorporated into the procedure. The method consists of sealing a test specimen into or against one face of a test chamber and supplying air to or exhausting air from the chamber according to a specific test loading program. C-1.2 The inward pressure level, P inward, that is used during the test shall be at the discretion of the test sponsor. The tests shall be conducted such that the ratio of the outward pressure to the inward pressure (P outward /P inward ) shall be either (-1.4) or (-2.0). The minimum pressure levels used in the test program shall be [(P outward /P inward ] -42 lbs/ft 2 and +30 lbs/ft 2 (-2.0 kpa and +1.45 kpa) when the pressure coefficient of (-1.4) is used and -60 lbs/ft 2 and +30 lbs/ft 2 (-2.9 kpa and +1.45 kpa) when the pressure coefficient of (-2.0) is used. C-2 Test Apparatus and Arrangement C-2.1 The description of the apparatus is general in nature. Any equipment capable of performing the test procedure within the allowable tolerances is permitted. Only the major components are described. C-2.2 Test Chamber the test chamber consists of a box shaped device with one side open onto which the specimen is installed. It shall incorporate a static pressure tap to measure the pressure difference across the specimen. The tap shall be located such that it is not affected by the velocity of the air supplied to or exhausted from the chamber. The air supply opening into the chamber shall be arranged so that the air does not impinge directly on the test specimen with any significant velocity. The test specimen mounting frame shall be of sufficient size so as not to deflect under the test load in a manner that will affect the performance of the test specimen. C-2.3 Air System the air system shall consist of a controllable blower, a compressed air supply, an exhaust system or a reversible controllable blower designed to provide the maximum air pressure differential across the specimen. The system shall provide an essentially constant air pressure difference for the required test period. C-2.4 Pressure Measuring Apparatus the pressure measuring apparatus used to measure the test pressure difference shall be capable of having a tolerance of ±2% or ±0.01 in. (±2.5 kpa) of water column, whichever is greater. C-2.5 Deflection Measuring System an optional deflection measuring system may be provided to measure deflections during the test. If used, such a device shall have a tolerance of ±0.01 in. (±0.25 mm). FM APPROVALS 17

4881 November 2007 C-3 Test Specimen C-3.1 The test specimen shall be of sufficient size and configuration to determine the performance of all components of the system and to provide full loading on each vertical and horizontal framing member but shall not be less than one (1) full building story height. It shall incorporate horizontal and vertical expansion joints. The conditions of structural support shall simulate, as accurately as possible, the actual structural conditions of a building. The distance between structural supports incorporated into the test specimen shall be the maximum support spacing granted in the Approval. C-3.2 The test specimen shall be subjected to both inward and outward acting static pressures. The specimen shall incorporate the same number and type of fasteners and anchors normally used when installing the system on a building. C-4 Test Procedure C-4.1 The test specimen shall be fitted onto or against the test chamber. Air shall be supplied to or exhausted from the system until the test pressure has been achieved. The rate of air supplied or exhausted shall be such that the design pressure is reached in not less than 5 seconds and not more than 15 seconds. C-4.2 If the test specimen is such that the specified air pressure can not be maintained, then any cracks or joints through which air leakage is occurring shall be sealed with tape or other effective means. As an alternate, the entire specimen can be covered with a single thickness of polyethylene film no thicker than 0.002 in. (0.05 mm). The application of the film shall be such that the maximum load is transferred to the test specimen and that the membrane does not prevent movement or failure of the specimen. The film should be applied loosely with extra folds of material at the corners and all offsets or recesses. C-4.3 Procedure A (+1.0P, -1.4P) [where + denotes P inward and denotes (P outward ] C-4.3.1 Air shall be supplied until the loading reaches +0.5P. The pressure shall be held at this level for a period of 60 seconds. Upon holding the pressure at +0.5P for 60 seconds, the pressure difference shall be released. The sample shall be allowed a recovery period of not less than one (1) minute or more than two (2) minutes. C-4.3.2 After the recovery period, air shall be supplied until the loading reaches +1.0P. The pressure shall be held at this level for a period of 60 seconds. Upon holding the pressure at +1.0P for 60 seconds, the pressure difference shall be released. The sample shall be allowed a recovery period of not less than one (1) minute or more than two (2) minutes. C-4.3.3 After the recovery period, air shall be supplied until the loading reaches -0.7P [0.5P (-1.4)]. The pressure shall be held at this level for a period of 60 seconds. Upon holding the pressure at -0.7P for 60 seconds, the pressure difference shall be released. The sample shall be allowed a recovery period of not less than one (1) minute or more than two (2) minutes. C-4.3.4 After the recovery period, air shall be supplied until the loading reaches -1.4P [1.0P (-1.4)]. The pressure shall be held at this level for a period of 60 seconds. Upon holding the pressure at -1.4P for 60 seconds, the pressure difference shall be released and examined. C-4.4 Procedure B (+1.0P, -2.0P) [where + denotes P inward and denotes (P outward ] C-4.4.1 Air shall be supplied until the loading reaches +0.5P. The pressure shall be held at this level for a period of 60 seconds. Upon holding the pressure at +0.5P for 60 seconds, the pressure difference shall be released. The sample shall be allowed a recovery period of not less than one (1) minute or more than two (2) minutes. 18 FM APPROVALS

November 2007 4881 C-4.4.2 After the recovery period, air shall be supplied until the loading reaches +1.0P. The pressure shall be held at this level for a period of 60 seconds. Upon holding the pressure at +1.0P for 60 seconds, the pressure difference shall be released. The sample shall be allowed a recovery period of not less than one (1) minute or more than two (2) minutes. C-4.4.3 After the recovery period, air shall be supplied until the loading reaches -1.0P [0.5P (-2.0)]. The pressure shall be held at this level for a period of 60 seconds. Upon holding the pressure at -1.0P for 60 seconds, the pressure difference shall be released. The sample shall be allowed a recovery period of not less than one (1) minute or more than two (2) minutes. C-4.4.4 After the recovery period, air shall be supplied until the loading reaches -2.0P [1.0P (-2.0)]. The pressure shall be held at this level for a period of 60 seconds. Upon holding the pressure at -2.0P for 60 seconds, the pressure difference shall be released and examined. C-4.5 As an alternative to Procedure B, upon completion of maintaining the -1.4P pressure level shown in Paragraph C-4.3.4 (Procedure A), the sample shall be allowed a recovery period of not less than one (1) minute or more than two (2) minutes. After the recovery period, air shall be supplied until the loading reaches -2.0P. The pressure shall be held at this level for a period of 60 seconds. Upon holding the pressure at -2.0P for 60 seconds, the pressure difference shall be released and examined. C-4.5.1 If the specimen meets the performance requirements shown in Paragraph C-5, it shall be deemed to have qualified for a rating based on +1.0P and -2.0P provided that the sample also meets the criteria of the Standard Test Method for Exterior Wall Systems Exposed to Cyclic Air Pressure Differentials using -2.0P as the outward pressure. C-5 Performance Requirements C-5.1 Upon completion of the test and upon examination, the test specimen shall show no signs of cracking or any other signs of failure. C-5.2 Both an inward acting (positive) and an outward acting (negative) wind load rating shall be assigned based on the maximum pressure levels successfully maintained. The ratings shall be based on the positive pressure rating in increments of 5 lbs/ft 2 (0.25 kpa). The pressure ratings shall be stated in multiples of +P, -1.4P or +P, -2P as applicable. FM APPROVALS 19

4881 November 2007 APPENDIX D Structural Test Method for Exterior Wall Systems Exposed to Cyclic Air Pressure Differentials D-1 Introduction D-1.1 This test method is intended to evaluate the structural performance of exterior wall systems. It is consistent with several well known test methods. The method consists of sealing a test specimen into or against one face of a test chamber and supplying air to or exhausting air from the chamber according to a specific test loading program. D-1.2 This test method offers two (2) different loading sequences. They shall be referred to as Procedure A and Procedure B. In each case, the test specimen size, apparatus, arrangement, pressure coefficients and basic procedure are identical. The number of cycles, pressure levels used and sequence of pressure applications varies depending on the exterior wall system s intended use. D-1.3 Procedure A shall be used to qualify exterior wall systems that are intended to be used in areas that are prone to hurricane force winds (Zones HM and H). The test method consists of a total of 9000 pressure cycles. It is conducted in accordance with several well known test methods such as ASTM E1886-02, SBCCI STD 12-99 and FBC TAS 203-95.1 D-1.3.1 When an exterior wall system is being qualified for use in areas that are also prone to the impact of windborne debris (Zone HM), the test specimen shall be subjected to the Test Method for Exterior Wall Systems Impacted by Windborne Debris (Appendix E) prior to being subjected to this procedure. D-1.4 Procedure B shall be used to qualify exterior wall systems that are intended to be used in areas that are not prone to hurricane force winds (Zone NH). The test method consists of 1056 pressure cycles. It is conducted in accordance with ASTM E1233-00, Table X1.2. D-1.5 The inward pressure level, P inward, that is used during the test shall be at the discretion of the test sponsor. The tests shall be conducted such that the ratio of the outward pressure to the inward pressure (P outward /P inward ) shall be either (-1.4) or (-2.0). The minimum pressure levels used in the test program shall be [P outward ;P inward ] -42 lbs/ft 2 and +30 lbs/ft 2 (-2.0 kpa and +1.45 kpa) when the pressure coefficient of (-1.4) is used and -60 lbs/ft 2 and +30 lbs/ft 2 (-2.9 kpa and +1.45 kpa) when the pressure coefficient of (-2.0) is used. D-2 Test Apparatus and Arrangement D-2.1 The description of the apparatus is general in nature. Any equipment capable of performing the test procedure within the allowable tolerances is permitted. Only the major components are described. D-2.2 Test Chamber the test chamber consists of a box shaped device with one side open onto which the specimen is installed. It shall incorporate a pressure tap to measure the pressure difference across the specimen. The tap shall be located such that it is not affected by the velocity of the air supplied to or exhausted from the chamber. The air supply opening into the chamber shall be arranged so that the air does not impinge directly on the test specimen with any significant velocity. The test specimen mounting frame shall be of sufficient size so as not to deflect under the test load in a manner that will affect the performance of the test specimen. 20 FM APPROVALS

November 2007 4881 D-2.3 Air System the air system shall consist of a controllable blower, a compressed air supply, an exhaust system or a reversible controllable blower designed to provide the maximum air pressure differential across the specimen. The system shall provide an essentially constant air pressure difference for the required test period. D-2.4 Pressure Measuring Apparatus the pressure measuring apparatus used to measure the test pressure difference shall be capable of having a tolerance of ±2% of its maximum rated capacity or ±2 lbs/ft 2 (±100 kpa), whichever is less and a response time less than 50 ms. Examples of acceptable apparatus are mechanical pressure gauges and electronic pressure transducers. D-2.5 Pressure Recording Device a pressure recording device shall be interconnected with the air pressure system and pressure measuring device such that the number of cycles, pressure levels and cycle times are recorded. D-3 Test Specimen D-3.1 Each test specimen shall be of sufficient size and configuration to determine the performance of all components of the system and to provide full loading on each vertical and horizontal framing member but shall not be less than one (1) full building story height. It shall incorporate horizontal and vertical expansion joints. The conditions of structural support shall simulate, as accurately as possible, the actual structural conditions of a building. The distance between structural supports incorporated into the test specimen shall be the maximum support spacing granted in the Approval. D-3.2 The test specimen shall be subjected to both inward and outward acting cyclic pressures as shown in Table D-1 or Table D-2. The specimen shall incorporate the same number and type of fasteners and anchors normally used when installing the system on a building. D-3.3 When an exterior wall system is being qualified for use in areas that are also subject to the impact of windborne debris (Zone HM), three (3) test specimens shall be examined. Each test specimen shall be subjected to the Test Method for Exterior Wall Systems Impacted by Windborne Debris prior to being subjected to this procedure. D-3.4 When an exterior wall system is being qualified for use in areas that are not subject to the impact of windborne debris, (Zone H and NH), only a single test specimen needs to be examined. D-4 Test Procedure D-4.1 Each test specimen shall be fitted onto or against the test chamber. The air pressure used shall be in accordance with either Procedure A (Zones HM and H) or Procedure B (Zone NH). Air shall be supplied to or exhausted from the system until the test pressure has been achieved. The duration of each air pressure cycle shall not be less than one (1) second or more than five (5) seconds. The dwell time between successive cycles shall be no more than one (1) second. D-4.2 If the test specimen is such that the specified air pressure can not be maintained, then any cracks or joints through which air leakage is occurring shall be sealed with tape or other effective means. As an alternate, the entire specimen can be covered with a single thickness of polyethylene film no thicker than 0.002 in. (0.05 mm). The application of the film shall be such that the maximum load is transferred to the test specimen and that the membrane does not prevent movement or failure of the specimen. The film should be applied loosely with extra folds of material at the corners and all offsets or recesses. D-4.3 Interruptions for equipment maintenance and repair shall be permitted. D-4.4 The test specimen shall be permitted to be removed, reversed and reinstalled in the chamber between the inward acting and outward acting pressure cycles. FM APPROVALS 21

4881 November 2007 D-4.5 Procedure A Apply the cyclic loads in accordance with Table D-1. P denotes the inward acting (positive) pressure. The negative sign denotes the outward acting (negative) pressure. The outward pressure shall be a ratio (-1.4 or -2.0) of the inward pressure as described in D-1.5. Loading Sequence Loading Direction Air Pressure Cycles Table D-1 No. of Air Pressure Cycles Outward Pressure Values Multiplied by a Ratio of -1.4 Outward Pressure Values Multiplied by a Ratio of -2.0 1 Inward 0.2P Inward 0.5P Inward 3500 NA NA 2 Inward 0.0P Inward 0.6P Inward 300 NA NA 3 Inward 0.5P Inward 0.8P Inward 600 NA NA 4 Inward 0.3P Inward 1.0P Inward 100 NA NA 5 Outward 0.3P Outward 1.0P Outward 50-0.4P/-1.4P -0.6P/-2.0P 6 Outward 0.5P Outward 0.8P Outward 1050-0.7P/-1.1P -1.0P/-1.6P 7 Outward 0.0P Outward 0.6P Outward 50 0.0P/-0.8P 0.0P/-1.2P 8 Outward 0.2P Outward 0.5P Outward 3350-0.3P/-0.7P -0.4P/-1.0P D-4.6 Procedure B Apply the cyclic loads in accordance with Table D-1. P denotes the inward acting (positive) pressure. The negative sign denotes the outward acting (negative) pressure. The outward pressure shall be a ratio (-1.4 or -2.0) of the inward pressure as described in D-1.5. Loading Sequence Loading Direction Air Pressure Cycles Table D-2 No. of Air Pressure Cycles Negative Pressure Values Multiplied by a Ratio of -1.4 Negative Pressure Values Multiplied by a Ratio of -2.0 1 Inward 0.0P Inward 0.6P Inward 12 NA NA 2 Inward 0.0P Inward 0.8P Inward 1 NA NA Repeat positive loading sequence 1 and 2 an additional four (4) times prior to loading sequence 3 3 Inward 0.0P Inward 1.0P Inward 1 NA NA 4 Outward 0.0P Outward 0.6P Outward 12 0.0P/-0.8P 0.0P/-1.2P 5 Outward 0.0P Outward 0.8P Outward 1 0.0P/-1.1P 0.0P/-1.6P Repeat negative loading sequence 4 and 5 an additional four (4) times prior to loading sequence 6 6 Outward 0.0P Outward 1.0P Outward 1 0.0P/-1.4P 0.0P/-2.0P Repeat the loading sequence 1 through 6, in the order designated an additional seven (7) times. D-5 Performance Requirements D-5.1 Both an inward acting (positive) and outward acting (negative) wind load rating shall be assigned based on the maximum pressure levels successfully maintained. The ratings shall be based on the inward acting pressure rating in increments of 5 lbs/ft 2 (0.25 kpa). The pressure ratings shall be stated in multiples of +P, -1.4P or +P, -2P as applicable. D-5.2 For exterior wall systems that are being qualified for use in areas that are not subject to the impact of wind debris (Wind Zones H and NH), the test specimen shall show no signs of cracking or any other signs of failure. 22 FM APPROVALS

November 2007 4881 D-5.3 For exterior wall systems that are being qualified for use in areas that are subject to the impact of wind debris (Wind Zone HM), see the Performance Requirements for the Test Method for Exterior Wall Systems Impacted by Windborne Debris. D-5.3.1 In addition to meeting the Performance Requirements stated in Paragraph D-5.3, a separate sample, not impacted by windborne debris, shall meet the criteria for a Wind Zone H Approval. This is to ensure that exterior wall panels FM Approved for use in Wind Zone HM meet the cyclic wind criteria when not impacted by windborne debris. FM APPROVALS 23

4881 November 2007 APPENDIX E Test Method for Exterior Wall Systems Impacted by Windborne Debris E-1 Introduction E-1.1 This test method is intended to evaluate the performance of exterior wall systems that are subject to the impact of windborne debris (Zone HM). The test method is based on several known test methods such as ASTM E1996-03, SBCCI STD 12-99 and FBC TAS 201-94 with several modifications incorporated. The modifications are basically a compilation of the existing test methods such that the resulting test method incorporates the most critical item from each test method. This should allow a manufacturer to meet all the major building codes by conducting a single set of tests. E-1.2 Two (2) levels of performance requirements have been provided. This is done to assist the manufacturer in gaining acceptance of the product(s) by local jurisdictions that utilize a building code that exceeds the minimum acceptance criteria of FM Approvals (most notably the Florida Building Code). E-1.3 Two (2) different levels of missile impact are offered. The large missile impact test consists of impacting a test specimen with an 8 ft (2.4 m) long wooden 2 4 weighing 9 lbs (4 kg) traveling at a speed of 50 ft/sec (15.25 m/s). Each sample shall be subjected to two (2) impacts at predetermined locations. The small missile impact test consists of impacting a test specimen with ten (10) steel balls, fired simultaneously, with each steel ball weighing 0.07 oz (2 g) traveling at a speed of 130 ft/sec (39.6 m/s). Each sample shall be subjected to three (3) impacts at predetermined locations. E-1.4 Following the impact test, each sample shall be subjected to Structural Test Method for Exterior Wall Systems Exposed to Cyclic Air Pressure Differentials, Procedure A (Appendix D). E-2 Test Apparatus and Arrangement E-2.1 Large Missile Impact Device The description of the apparatus is general in nature. Any equipment capable of performing the test procedure within the allowable tolerances is permitted. Only the major components are described. E-2.1.1 The Large Missile Cannon shall be used to deliver the large missile. The cannon consists of a 4 in. (100 mm) internal diameter pipe that is approximately 12 ft (3.7) in length mounted onto a support frame. Compressed air is supplied to the cannon and monitored by a pressure gauge. A remote firing device and valve shall be used to fire the missile. E-2.1.2 The large missile shall consist of an 8 ft ±4 in. (2.4 m ± 100 mm) long wooden 2 4, (Southern Yellow Pine or Douglas Fir) weighing 9 ±0.25 lbs (4100 ± 100g). The 2 4 shall be free of knots and splits within 12 in. (300 mm) of the impact end. A shabot shall be permitted on the trailing edge to facilitate launching. If used, the shabot s weight shall be considered in determining the missile s total weight. E-2.1.3 A timing system shall be provided. It shall be capable of measuring the speed of the missile within a tolerance of 1 ft/sec (0.3 m/s). E-2.1.4 The test sample shall be mounted vertically within or onto a test frame. The test frame shall be of sufficient size, strength and be adequately anchored to withstand the anticipated forces of the impacting missile without resulting in noticeable damage or excessive deflection. The mounting frame shall either be integral with the cyclic air test chamber or capable of being installed on the test chamber used in the Structural Test Method for Exterior Wall Systems Exposed to Cyclic Air Pressure Differentials. 24 FM APPROVALS

November 2007 4881 E-2.2 Small Missile Impact Device The description of the apparatus is general in nature. Any equipment capable of performing the test procedure within the allowable tolerances is permitted. Only the major components are described. E-2.2.1 The Small Missile Cannon shall be used to deliver the small missile. The cannon consists of a 1 in. (25 mm) internal diameter pipe that is approximately 4 ft (1.2 m) in length mounted onto a support frame. Compressed air is supplied to the cannon and monitored by a pressure gauge. A remote firing device and valve shall be used to fire the missile. E-2.2.2 The small missile shall consist of ten (10) steel balls fired simultaneously with each steel ball weighing 0.07 oz (2 g). E-2.2.3 A timing system shall be provided. It shall be capable of measuring the speed of the missile within a tolerance of 1 ft/sec (0.3 m/s). Only the speed of one (1) steel ball needs to be monitored in order to determine the projectile speed. E-2.2.4 The test sample shall be mounted vertically within or onto a test frame. The test frame shall be of sufficient size, strength and be adequately anchored to withstand the anticipated forces of the impacting missile without resulting in noticeable damage or excessive deflection. The mounting frame shall either be integral with the test chamber or capable of being installed on the test chamber used in the Structural Test Method for Exterior Wall Systems Exposed to Cyclic Air Pressure Differentials. E-3 Test Specimen The test specimen shall be of sufficient size and configuration to determine the performance of all components of the system and to provide full loading on each vertical and horizontal framing member but shall not be less than one (1) full building story height. It shall incorporate horizontal and vertical expansion joints. The conditions of structural support shall simulate, as accurately as possible, the actual structural conditions of a building. The distance between structural supports incorporated into the test specimen shall be the maximum support spacing granted in the Approval. E-4 Test Procedure E-4.1 Large Missile Impact E-4.1.1 When ready for testing, the Large Missile Cannon shall be positioned such that each test specimen receives a series of two (2) impacts of the large missile. The end of the cannon shall be located approximately 14 ft (4.3 m) away from the face of the test specimen. The first missile shall impact the test specimen within a 5 in. (125 mm) radius circle located at the center of the test specimen. The second missile shall impact a corner of the test specimen within a 5 in. (125 mm) radius circle centered no more than 6 in. (150 mm) away from any supporting members. E-4.1.2 The large missile shall impact the surface of the test specimen with a speed of 50-52 ft/sec (15.2-15.8 m/s) which is approximately 35 miles/hour (56 km/hr). FM APPROVALS 25

4881 November 2007 E-4.2 Small Missile Impact E-4.2.1 When ready for testing, the Small Missile Cannon shall be positioned such that each test specimen receives a series of three (3) impacts of the small missile. The end of the cannon shall be located at an appropriate distance from the test panel such that the missiles are distributed over a maximum spread of 2 ft 2 (0.2 m 2 ). The series of impacts shall be located at the center of the test specimen, along the edge of the center of the long dimension of the test specimen and at one corner of the test specimen. E-4.2.2 The small missile shall impact the surface of the test specimen with a speed of 130-132 ft/sec (39.6-40.2 m/s) which is approximately 90 miles/hour (145 km/hr). E-5 Performance Requirements E-5.1 Wind Zones HM-LM and HM-SM E-5.1.1 To obtain Approval for either Large Missile Impact Resistance [Wind Zone HM-LM] or Small Missile Impact Resistance [Wind Zone HM-SM], upon completion of the cyclic pressure test (which follows the impact test), all three (3) samples shall not develop any openings more than 5 in. (125 mm) in length or any through openings through which a 3 in. (75 mm) diameter solid sphere can freely pass. E-5.2 Wind Zones HM-LM(FL) and HM-SM(FL) E-5.2.1 To obtain Approval for either Large Missile Impact Resistance [Wind Zone HM-LM (FL)] or Small Missile Impact Resistance [Wind Zone HM-SM (FL)], upon completion of the cyclic pressure test (which follows the impact test), all three (3) samples shall have no penetration of the impact protective system by the missile (for the impact test) and during the cyclic test, shall not develop any openings more than 5 in. (125 mm) in length or 1 16 in. (1.6 mm) in width through which air can pass. 26 FM APPROVALS

November 2007 4881 APPENDIX F Simulated Hail Resistance Test Using Freezer Ice Balls F-1 Introduction F-1.1 This test method is intended to evaluate the performance of exterior wall systems when subjected to the impact of simulated hail. It is based on Approval Standard 4470, Class 1 Roof Covers, Appendix F and Test Standard 4473, Specification Test Protocol for Impact Resistance Testing of Rigid Roofing Materials by Impacting with Freezer Ice Balls. This test is consistent with Standard 4470 in that equivalent impact energies are used but different in that it utilizes ice balls instead of steel balls. F-1.2 Two ratings are available Severe (S) and Moderate (M). The Severe Hail rating will consist of a nominal 1.75 in. (44 mm) diameter ice ball having a kinetic energy of 14.9 ft-lbs (20.3 J). The Moderate Hail rating shall consist of a nominal 1.5 in. (38 mm) diameter ice ball having a kinetic energy of 7.8 ft-lbs (10.4 J). The impact speeds are 101.8 ft/sec (31.0 m/sec) and 92.5 ft/sec (28.2 m/sec), respectively. F-2 Test Apparatus and Arrangement F-2.1 The description of the apparatus is general in nature. Any equipment capable of performing the test procedure within the allowable tolerances is permitted. Only the major components are described. F-2.2 Launcher the launcher shall be a device capable of propelling ice balls at the speeds necessary to develop the intended kinetic energy. Aiming accuracy of the launcher must be sufficient to assure that the ice balls strike the test specimen at the specified impact areas. F-2.3 Velocity Measuring Device a velocity measuring device shall be used to monitor the speed of the ice balls. It shall be accurate within ±1 ft/sec (±0.3 m/sec). F-2.4 Conditioning Box or Freezer a conditioning box or freezer shall be capable of maintaining the conditioning requirements stated below. F-3 Test Specimen F-3.1 The test specimen shall be a minimum of 3 ft 3 ft (0.9 0.9 m) and a maximum of 4 ft 4ft (1.2 1.2 m) in size and shall be representative of the samples being considered for Approval. The test specimen shall be placed over 1 2 in. (13 mm) thick plywood if necessary. F-3.2 The test specimen shall be conditioned at 40 F ±5 F (4 C ±3 C) for a period of not less than 48 hours immediately prior to the test. It shall be tested within five (5) minutes of being removed from the conditioning box. FM APPROVALS 27

4881 November 2007 F-3.3 The ice balls shall be molded using distilled water by placing them in a freezer for a minimum of 48 hours at a controlled temperature of -7 F ±7 F (-22 C ±4 C) until they are frozen solid. Acceptable ice balls shall be free of cracks and air bubbles. They shall meet the criteria listed in Table F-1 within 0 and +10% of the values shown. The ice balls shall be propelled at the sample within two (2) minutes of being removed from the freezer. Nominal Ice Ball Diameter in. (mm) Table F-1 Mass in Pounds (g) 1.5 (38) 0.0584 (26.5) 1.75 (44) 0.0928 (42.1) F-4 Test Procedure F-4.1 Calibrate the ice ball launcher to meet the minimum missile speeds shown in Table F-2. These speeds are designed to impart the kinetic energies shown. The calibrated speed used during the tests shall not exceed the values shown by more than 5 ft/sec (1.5 m/sec). F-4.2 Maintain the temperature of the test area between 60 F and 90 F (16 C and 32 C). F-4.3 Remove the test specimen from its conditioning box and position it vertically to assure that the trajectory of the ice ball is perpendicular (90 ±5 ) to the test specimen and to determine the impact locations. Once the impact locations have been determined, remove a sufficient number of ice balls from the freezer. F-4.3.1 In order to obtain a Severe Hail rating, the test specimen shall be impacted with the 1.75 in. (44 mm) diameter ice balls as shown in Table F-2. In order to obtain a Moderate Hail rating, the test specimen shall be impacted with the 1.5 in. (38 mm) diameter ice balls as shown in Table F-2. F-4.4 The test specimen shall be impacted a total of ten (10) times with the appropriate ice balls in three (3) areas. The test specimen shall be impacted four (4) times within a 12 in. (300 mm) diameter circle located at the center of the specimen. The specimen shall be impacted three (3) times along the top edge of the specimen within three (3) in. (75 mm) of the edge of the specimen. The specimen shall be impacted three (3) times along one (1) side edge of the specimen within three (3) in. (75 mm) of the edge of the specimen. Each missile shall be fired separately. F-5 Performance Requirements The specimen shall be considered to meet the test criteria if there is no sign of cracking or splitting after being impacted as described above. Nominal Ice Ball Diameter, in (mm) Table F-2 Missile Impact Speed, ft/sec (m/sec) Kinetic Energy, ft-lbs (J) 1.5 (38) 92.5 (38) 7.8 (10.4) 1.75 (44) 101.8 (31.0) 14.9 (20.3) 28 FM APPROVALS

November 2007 4881 APPENDIX FLA Specification Tested Product Listing for High-Velocity Hurricane Zones in Florida FLA-I Introduction FLA-1.1 FM Approvals Standard 4881, Approval of Exterior Wall Panels, was developed for use by FM Global and other authorities having jurisdiction. The Standard was written based on a review of existing test methods that were in the public domain at that time. FLA-1.1.1 This Appendix will assist customers of FM Approvals who are in the process of obtaining Approval in also qualifying their products for use in the State of Florida by obtaining a listing from FM Approvals as a Specification Tested Product that will also satisfy the performance criteria required by the Test Protocols for High-Velocity Hurricane Zones in Florida. FLA-1.2 Meeting the requirements of this Appendix does not by itself automatically qualify a manufacturer s product for use in Florida. It is recommended that the manufacturer refer to the Florida Product Approval Program for details in satisfying those requirements. FLA-1.3 The description of the test procedures contained in this Appendix are summaries of the actual test procedures. Copies of the complete protocols shall be available and followed when the actual tests are conducted. The criteria contained in any of the test protocols referenced in this Appendix will take precedence over any inconsistencies, should they occur, between this Appendix and the test protocols. FLA-II References The following are standards, test methods and practices referenced in this Appendix: 2004 Florida Building Code Testing Application Standard (TAS) 201-94, Impact Test Procedures Testing Application Standard (TAS) 202-94, Criteria for Testing Impact and Non-Impact Resistant Building Envelope Components Using Uniform Static Air Pressures Testing Application Standard (TAS) 203-94, Criteria for Testing Products to Cyclic Wind Pressure Loading ASTM E 283-04, Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen FM APPROVALS 29

4881 November 2007 FLA-III Definitions The following definitions shall be used in this Appendix: Design Pressure (Design Wind Load) The uniform static air pressure difference, inward or outward, for which the specimen would be designed under service load conditions Design Wind Load (see Design Pressure) Maximum Deflection The maximum displacement of the specimen measured to the nearest 1 8 of an inch (3 mm) attained from the original position while the maximum test load is being applied. One Cycle Beginning at the specified static air pressure, the application of the positive cyclic test load, and returning to the specified static air pressure, followed by the application of the negative cyclic test load. Permanent Deformation The permanent displacement of the specimen measured to the nearest 1 8 of an inch (3 mm) from the original position to the final position that remains after the maximum test load has been removed. Positive (Negative) Cyclic Load the specified differential in static air pressure, creating an inward (outward) loading, for which the specimen is to be tested under repeated conditions, expressed in pounds per square foot. Specimen The entire assembled unit that is submitted for testing, including but not limited to, anchorage devices and the structure to which the product is to be mounted. Specimen Failure A change in condition of the specimen indicative of deterioration under repeated load or incipient failure, such as cracking, fastener loosening, local yielding, or loss of adhesive bond. Test Chamber An airtight enclosure of sufficient depth to allow unobstructed deflection of the specimen during the pressure cycling, including ports for air supply and removal, and equipped with instruments to measure test pressure differentials. Test Load One and one-half (1.5) times the design pressure (positive or negative) as determined by Section 1620 of the Florida Building Code, Building for which the specimen is to be tested, expressed in lb/ft 2 (kn/m 2 ). FLA-IV Test Specimens FLA-4.1 All parts of the test specimen shall be full size, using the same materials, details, methods of construction and methods of attachment as proposed for actual use. The specimen shall consist of the entire assembled unit attached to a given type of structural framing of the building, and shall contain all devices used to resist wind forces and windborne debris. FLA-4.2 Remove from the test specimen any sealing or construction material that is not normally used when installed in or on a building. Fit the specimen with its structural framing into or against the chamber opening. The outdoor side of the specimen shall face the higher pressure side for positive loads; the indoor side shall face the higher pressure side for negative loads. Support and secure the specimen by the same number and type of anchors to be approved for normal installation of the specimen in the building. 30 FM APPROVALS

November 2007 4881 FLA-V Testing Application (TAS) 201-94, Impact Test Procedures FLA-5.1 Test Apparatus The description of the apparatus is general in nature. Any equipment, properly certified, calibrated and capable of performing this test within the allowable tolerance is permitted. Only the major components are described. FLA-5.1.1 Test Chamber The test chamber, to which the specimen is mounted, shall be provided with pressure taps to measure the pressure difference across the test specimen and shall be so located that the reading is unaffected by the velocity of air supplied to or from the chamber. The specimen mounting frame must not deflect under test load in such a manner that the performance of the specimen will be affected. FLA-5.1.2 Air System A controllable blower, a compressed-air supply, an exhaust system, or reversible controllable blower designed to provide the required maximum air pressure difference across the specimen. The system shall provide an essentially constant air-pressure difference for the required test period. FLA-5.1.3 Large Missile The large missile shall be a solid S4S nominal 2x4 #2 surface dry Southern Pine board. The weight of the missile shall be as specified in Section 1626.2.3 of the Florida Building Code, Building and shall have a length of not less than 7 feet (2.1 m) and not more than 9 feet (2.7 m). The missile shall be marked/ ticked in dark ink at one inch intervals on center, and congruently numbered every three inches. A sabot shall be attached to the trailing edge of the missile to facilitate launching. The weight of the sabot shall not exceed 1 2 lb (0.24 kg). The combined weight of the timber and sabot, which constitutes the missile, shall be between 9 lb (4.1 kg) and 9.5 lb (4.3 kg). The missile shall be propelled through a cannon as described in Section 5.1.4 of this Appendix. FLA-5.1.4 Large Missile Cannon The large missile cannon shall use compressed air to propel the large missile. The missile cannon shall consist of the following major components: a compressed air supply, a pressure release valve, a pressure gauge, a barrel and support frame, and a timing system for determining the missile speed. The barrel of the large missile cannon shall consist of a 4-inch (102 mm) inside diameter pipe and shall be at least as long as the missile. The barrel of the large missile cannon shall be mounted on a support frame in a manner to facilitate aiming the missile so that it impacts the specimen at the desired location. The distance from the end of the cannon to the specimen shall be 9 feet (2.7 m) plus the length of the missile. FLA-5.1.5 Small Missile The missiles shall be propelled through a cannon as described in Section 5.1.6 of this Appendix. The small missile shall be launched in such a manner that each specimen shall be impacted over an area not to exceed 2 ft 2 (0.19 m 2 ) per impact as described in Section 1626.3.5 of the Florida Building Code, Building. FLA-5.1.6 Small Missile Cannon A compressed air cannon shall be used that is capable of propelling missiles of the size and speed defined in 1626.3.3 and 1626.3.4 of the Florida Building Code, Building. The cannon assembly shall be comprised of a compressed air supply and gauge, a remote firing device and valve, a barrel, and a timing system. The small missile cannon shall be mounted to prevent movement of the cannon so that it can propel missiles to impact the test specimen at points defined in 1626.3.5 of the Florida Building Code, Building. The timing system shall be positioned to measure missile speed within 5 feet (1.5 m) of the impact point on the test specimen. FM APPROVALS 31

4881 November 2007 FLA-5.2 Test Procedure FLA-5.2.1 Large Missile Impact FLA-5.2.1.1 When ready for testing, the Large Missile Cannon shall be positioned such that each test specimen receives a series of two (2) impacts of the large missile. The end of the cannon shall be located approximately 9 ft (2.7 m) plus the length of the missile from the face of the test specimen. The first missile shall impact the test specimen within a 5 in. (125 mm) radius circle located at the midpoint of the test specimen. The second missile shall impact a corner of the test specimen within a 5 in. (127 mm) radius circle centered no more than 6 in. (150 mm) away from any supporting members. FLA-5.2.1.2 The large missile shall impact the surface of the test specimen with a speed of 50-52 ft/s (15.2-15.8 m/s) which is approximately 35 miles/hr (56 km/hr). FLA-5.2.2 Small Missile Impact FLA-5.3 Performance Requirements FLA-5.2.2.1 When ready for testing, the Small Missile Cannon shall be positioned such that each test specimen receives a series of three (3) impacts of the small missile. The end of the cannon shall be located at an appropriate distance from the test panel such that the missiles are distributed over a maximum spread of 2 ft 2 (0.19 m 2 ). The timing system shall be positioned within 5 ft (1.5 m) of the impact point of the test specimen. The series of impacts shall be located at the center of the test specimen, along the edge of the center of the long dimension of the test specimen and at one corner of the test specimen. FLA-5.2.2.2 The small missile shall impact the surface of the test specimen with a speed of 130-132 ft/s (39.6-40.2 m/s) which is approximately 90 miles/ hour (145 km/hr). FLA-5.3.1 Upon completion of the impact tests described above, the specimen shall be subjected to Testing Application (TAS) 203-94, Criteria for Testing Products Subject to Cyclic Wind (Section FLA-VII of this Appendix). FLA-5.3.1.1 Non-glazed test assemblies shall be cycled tested as specified in Table 1625.4. Test assemblies that incorporate glazing shall be cycled as specified in Table 1626. FLA-5.3.1.2 In the case of Table 1625.4, the test protocol shall be repeated for negative pressures. FLA-5.3.2 A particular system of construction shall be deemed to comply if the three (3) test specimens reject the missile impacts without penetration and resist the cyclic pressure loading with no crack forming longer than 5 in. (127 mm) in length or 1 16 in. (1.6 mm) in width through which air can pass. 32 FM APPROVALS

November 2007 4881 FLA-VI Testing Application (TAS) 202-94, Criteria for Testing Impact and Non-Impact Resistant Building Envelope Components Using Uniform Static Air Pressure FLA-6.1 Test Apparatus The description of the apparatus is general in nature. Any equipment, properly certified, calibrated and capable of performing this test within the allowable tolerance is permitted. Only the major components are described. FLA-6.1.1 Test Chamber The test chamber, to which the specimen is mounted, shall be provided with pressure taps to measure the pressure difference across the test specimen and shall be so located that the reading is unaffected by the velocity of air supplied to or from the chamber. The specimen mounting frame must not deflect under test load in such manner that the performance of the specimen will be affected. FLA-6.1.2 Pressure-Measuring Apparatus The pressure-measuring apparatus shall measure the test pressure difference within a tolerance of ±2%. FLA-6.1.3 Deflection-Measuring System The deflection-measuring system shall measure the deflection within a tolerance of 0.01 of an inch (2.5 Pa). FLA-6.1.4 Air System A controllable blower, a compressed-air supply, an exhaust system, or reversible controllable blower designed to provide the required maximum air pressure difference across the specimen. The system shall provide an essentially constant air-pressure difference for the required test period. FLA-6.1.5 Water-Spray System - The water-spray system shall deliver water uniformly against the exterior surface of the test specimen at a minimum rate of 5.0 gph/ft 2 (210 lph/m 2 ). The water-spray system shall have nozzles spaced at a uniform grid, located at uniform distance, and be adjustable to provide the specified quantity of water in such a manner as to wet the test specimen uniformly and to wet those areas vulnerable to water leakage. FLA-6.2 Uniform Static Air Test Procedure FLA-6.2.1 Install the test specimen onto the test chamber. FLA-6.2.2 Install all required measurement devices. FLA-6.2.3 Apply one half (0.5) of the test load and hold for 30 seconds. Release the test load across the specimen, and after a recovery period of not less than 1 minute nor more than 5 minutes, apply one half the reverse test load and hold for 30 seconds. Release the reverse test load and after a recovery period of not less than 1 minute nor more than 5 minutes record all readings. FLA-6.2.4 Apply the full test load and hold for 30 seconds. Release the test load across the specimen, and after a recovery period of not less than 1 minute nor more than 5 minutes, apply the full reverse test load and hold for 30 seconds. Release the reverse test load and after a recovery period of not less than 1 minute nor more than 5 minutes record all readings. FLA-6.3 Water Spray Test Procedure Deliver and maintain water spray at a minimum rate of 5 gph/ 2 (210 lph/m 2 ), applied at a pressure equal to not less than 15% of design pressure, maintain this pressure and water spray for a period not less than 15 minutes. FLA-6.4 Air Infiltration Test Procedure- shall comply with ASTM E 283. FM APPROVALS 33

4881 November 2007 FLA-6.5 Performance Requirements FLA-6.5.1 During the Uniform Static Air Test, the specimen shall show no signs of specimen failure. FLA-6.5.2 During the Water Spray Test, no water infiltration shall occur. FLA-6.5.3 During the Air Infiltration Test, the specimen shall meet the criteria as specified in ASTM E 283. FLA-VII Testing Application (TAS) 203-94, Criteria for Testing Products Subject to Cyclic Wind FLA-7.1 FLA-7.1.1 Test Apparatus The description of the apparatus is general in nature. Any equipment, properly certified, calibrated and capable of performing this test within the allowable tolerance is permitted. Only the major components are described. FLA-7.1.2 Test Chamber The test chamber, to which the specimen is mounted, shall be provided with pressure taps to measure the pressure difference across the test specimen and shall be so located that the reading is unaffected by the velocity of air supplied to or from the chamber. The specimen mounting frame must not deflect under test load in such manner that the performance of the specimen will be affected. FLA-7.1.3 Pressure-Measuring Apparatus The pressure-measuring apparatus shall measure the test pressure difference within a tolerance of ±2%. FLA-7.1.4 Deflection-Measuring System The deflection-measuring system shall measure the deflection within a tolerance of 0.01 of an inch (2.5 Pa). FLA-7.1.5 Air System A controllable blower, a compressed-air supply, an exhaust system, or reversible controllable blower designed to provide the required maximum air pressure difference across the specimen. The system shall provide an essentially constant air-pressure difference for the required test period. FLA-7.2 Test Procedure FLA-7.2.1 If the impact test is to be performed on the test specimen, such test shall be conducted prior to performing the test described in this section. FLA-7.2.2 Load the specimen using the design pressure, P, using the cycles specified in section Table 1625.4 and/or Table 1626 of the Florida Building Code, Building, whichever of these apply. FLA-7.2.2.3 Non-glazed test assemblies shall be cycled tested as specified in Table 1625.4. Test assemblies that incorporate glazing shall be cycled as specified in Table 1626. FLA-7.2.3 In the case of Table 1625.4, the protocol must be repeated for negative pressures. Table 1625.4 Fatigue Loading Sequence Range of Test Number of Cycles 0 to 0.5 P 600 0 to 0.6 P 70 0to1.3P 1 34 FM APPROVALS

November 2007 4881 Loading Sequence Loading Direction Table 1626 Cyclic Wind Pressure Loading Air Pressure Cycles No. of Air Pressure Cycles 1 Inward 0.2P Max 0.5P Max 3500 2 Inward 0.0P Max 0.6P Max 300 3 Inward 0.5P Max 0.8P Max 600 4 Inward 0.3P Max 1.0P Max 100 5 Outward 0.3P Max 1.0P Max 50 6 Outward 0.5P Max 0.8P Max 1050 7 Outward 0.0P Max 0.6P Max 50 8 Outward 0.2P Max 0.5P Max 3350 FLA-7.3 Performance Requirements FLA-7.3.1 Upon completion of the cycling test described in Paragraph 7.2.2 and/or 7.2.3, a particular system of construction shall be deemed to comply if the three (3) test specimens have rejected the missile impacts without penetration and resist the cyclic pressure loading with no crack forming longer than 5 in. (127 mm) in length or 1 16 in. (1.6 mm) in width through which air can pass. FLA-7.3.2 Assemblies shall be tested with no resultant failure or distress and shall have a recovery of at least 90% over the maximum deflection. FLA-VIII Operational Requirements for Specification Tested Products Listed By FM Approvals FLA-8.1 Markings The packaging for exterior wall systems shall bear the manufacturer s name, product trade name and the words, Specification Tested Product per FM Approvals Standard 4881, Appendix FLA. FLA-8.2 Installation Instructions The manufacturer shall make every reasonable effort to supply all necessary instructions and other assistance to the installer to ensure proper installation. Printed application instructions shall be provided by the manufacturer to demonstrate proper installation procedures. FLA-8.3 Drawings and Specifications The manufacturer shall provide FM Approvals with complete system drawings and raw material specifications, including proprietary formulation(s), if applicable. Further, the manufacturer shall notify FM Approvals of any change in the manufacturing procedures or materials used in the FM listed components prior to general sale and distribution. FLA-8.4 Other Requirements All samples submitted for testing shall be representative of production run material. Listed exterior wall systems shall be manufactured with the identical raw materials and fabrication techniques as originally tested. The specifications shall be kept on file at FM Approvals. FLA-IX Test Reports At a minimum, test reports shall contain all of the information specified in Section 10 of TAS 201-94; Section 10 of TAS 202-94 and Section 11 of TAS 203-94. FM APPROVALS 35

Printed in USA