CF-Mesa, CF-Light Mesa, CF-Flute, CF-Metl-Plank, CF-Striated, CF-Santa Fe, CF-Architectural Flat, CF...
|
|
|
- Marian Anabel Jennings
- 10 years ago
- Views:
Transcription
1 Building Insulations - Walls and Ceilings (FM Approval Numbers 4411, 4651, 4880, 4881, 4882) Insulating materials may occur in building construction to reduce heat or sound transmission through a wall, roof or floor-ceiling assembly. See Roofing Products and Assemblies Category for roof insulations. The insulation listed below may be a surface treatment exposed to the building occupancy or as core material faced with metal, gypsum wallboard, concrete or masonry. The listed assemblies are not intended as long-term fire walls or barriers since fire endurance was not evaluated. See SPECIFICATION TESTED PRODUCTS, ASTM E119 Standard, for hourly rated systems. Exterior Wall Constructions ( Number 4881) FM Approved exterior wall systems are 1 fire rated in accordance with Approval Standard exterior wall systems may be rated for use to unlimited height, a maximum height of 50 ft (15.2 m) or a maximum height of 30 ft (9.1 m). FM Approved 1 exterior wall assemblies have a wind load rating expressed as a pair of inward and outward acting pressures (P inward and P outward or +P/-P) determined using a combination of static and cyclic pressure tests. The rating is the lowest pair of pressures (inward and outward) attained in the static pressure test or the cyclic pressure test. The ratings are in increments of 5 psf (0.24 kpa) based on the inward (positive) pressure. The minimum rating for Approval is 30 psf (1.44 kpa) for the inward (positive) pressure. The magnitude of the pressure on the leeward side of a building is equal or higher than the pressure on the windward side so the outward pressure is based on pressure coefficients of either (-1.4P) or (-2.0P) based on an applied pressure (+P) on the windward side. FM Global Property Loss Prevention Data Sheet 1-28 is used to determine the minimum wind load rating(s) required based on the building's geometry and geographic location. FM Global recognizes three (3) different wind zones referred to as M, and Zone NH. The FM Global Property Loss Prevention Data Sheets are used to determine which zone applies for a particular location. M is used to denote those exterior wall assemblies that have been qualified for locations that are subject to both hurricane force winds and missile impact from windborne debris. Assemblies may meet the requirements of either the large missile (-LM) or the small missile (-SM) impact test. Assemblies meeting the missile requirements of the Florida Building Code are further designated as (FL) after the -LM or -SM designation. is used to denote those exterior wall assemblies that have been qualified for locations that are subject to hurricane force winds but not subject to missile impacts from windborne debris. Zone NH is used to denote those exterior wall assemblies in non-hurricane zones that are not subjected to either hurricane force winds or missile impacts from windborne debris. FM Approved 1 exterior wall assemblies have a Hail Resistance Rating determined using tests that simulate the expected impact of hail. The ratings available are Severe and Moderate. The ratings are consistent with corresponding ratings and impact energies used in Approval Standard 4470, 1 Roof Covers. FM Global Loss Prevention Data Sheet 1-29 is used to determine the impact (hail) rating needed for a particular geographic location. The entries in the table should be interpreted as follows: Thickness indicates the minimum Approved panel thickness (usually wind test related) and the maximum Approved panel thickness (usually fire test related). Width indicates the minimum Approved panel coverage width (usually fire test related) and the maximum Approved panel width (usually wind test related). Maximum Height indicates the maximum continuous height of panels that may be installed (fire test related). Hail Resistance Ratings, Wind Load Ratings and Zones are described above. Maximum Support Steel Spacing is the maximum spacing between steel supports, Minimum Support Steel Thickness is the minimum steel support thickness and Minimum Support Steel Yield Stress is the minimum steel support strength required to achieve the indicated Wind Load Ratings. See the listings in the FM Approvals Standard 4880 (2005) Wall-Ceiling/Roof Constructions section earlier in the Exterior Wall Construction Category for a description of each panel listed below. Products identified with the symbol have attributes that are considered to be sustainable by certain outside organizations. FM Approvals verifies the presence of these attributes. Specific attributes for specific products are listed in the individual listings. To facilitate a search for these products in the Approval Guide, first search by the product type you desire and then refine your search to products with the symbol. CF-Flute, CF-Metl-Plank, CF... Wall Panel Thickness/ Securement Width Max Height Hail Resistance Rating Wind Load Rating & Zone Max Support Steel Spacing Min Support Steel Thickness Min Support Steel Yield Stress CF-Striated, CF-Architectural Flat (50-150/ 24 in. ( /-147 in. (1.80 ] (315 MPa) CF-Striated, CF-Architectural Flat ( / 24 in. ( /-112 ] (315 MPa) FM Approvals. All rights reserved. 1 of 19
2 , CF 7.2 ( / /-42 in. (1.80 ], CF 7.2 ( / /-56 in. (1.80 ], CF 7.2 ( / /-63 in. (1.80 ], CF 7.2 ( / /-84 ], CF 7.2 ( / /-49 in. (1.80 ], CF 7.2 ( / /-56 in. (1.80 ], CF 7.2 ( / /-70 in. (1.80 ], CF 7.2 ( / /-42 in. (1.80 ], CF 7.2 ( / /-49 in. (1.80 ] FM Approvals. All rights reserved. 2 of 19
3 , CF 7.2 ( / /-63 in. (1.80 ] ( / /-42 in. (1.80 ] ( / /-49 in. (1.80 ] ( / /-63 in. (1.80 ] ( / / ft 8 in. (3250 in. (1.80 ] ( / /-49 in. (1.80 ] ( / /-56 in. (1.80 ] ( / /-63 in. (1.80 ] ( / /-70 in. (1.80 ] ( / /-84 in. (1.80 ] FM Approvals. All rights reserved. 3 of 19
4 ( / /-112 in. (1.80 ] ( / 24- in. (1.80 ] ( / 24- in. (1.80 ] ( / 24- in. (1.80 ] ( / 24- in. (1.80 ] ( / 24- in. (1.80 ] ( / /-105 in. (1.80 ] ( / 24- in. (1.80 ] ( / 24- in. (1.80 ] ( / 24- in. (1.80 ] FM Approvals. All rights reserved. 4 of 19
5 ( / 24- in. (1.80 ] ( / /-98 in. (1.80 ] ( / /-42 9 ft 3 in. in. (1.80 ] ( / /-49 in. (1.80 ] ( / /-63 in. (1.80 ] ( / /-77 in. (1.80 ] ( / /-98 in. (1.80 ] ( / /-42 Zone HM-LM (FL) 14 ft 6 in. (4420 in. (1.80 ] ( / /-49 (3660 in. (1.80 ] ( / /-56 in. (1.80 ] FM Approvals. All rights reserved. 5 of 19
6 ( / /-63 in. (1.80 ] ( / /-77 in. (1.80 ] ( / /-84 in. (1.80 ] ( / /-105 in. (1.80 ] ( / /-112 in. (1.80 ] ( / /-147 in. (1.80 ] ( / / ft 0 in. (915 in. (1.80 ] ( / /-175 Zone HM-LM(FL) 3 ft 0 in. (915 ] ( / 24- (3660 ] ( / 24- ] FM Approvals. All rights reserved. 6 of 19
7 ( / 24- ] ( / 24- ] ( / 24- ] ( / /-91 ] ( / /-105 ] ( / /-133 ] ( / / ft 0 in. (915 ] ( / 24- (3660 ] ( / 24- ] ( / 24- ] FM Approvals. All rights reserved. 7 of 19
8 ( / 24- ] ( / 24- ] ( / /-84 ] ( / /-98 ] ( / /-126 ] ( / / ft 0 in. (915 ] ( / /-42 Zone HM-LM (FL) (3660 in. (1.80 ] ( / /-49 in. (1.80 ] ( / /-56 in. (1.80 ] ( / /-63 in. (1.80 ] FM Approvals. All rights reserved. 8 of 19
9 ( / /-70 in. (1.80 ] ( / /-84 in. (1.80 ] ( / /-98 in. (1.80 ] ( / /-126 in. (1.80 ] ( / /-119 Zone HM-LM(FL) ] (315 MPa) ( / / ft 0 in. (915 in. (1.80 ] ( / /-154 Zone HM-LM (FL) 3 ft 0 in. (915 ], CFI 7.2 ( / ], CFI 7.2 ( / ], CFI 7.2 ( / ] FM Approvals. All rights reserved. 9 of 19
10 , CFI 7.2 ( / +60/-84 ], CFI 7.2 ( / ], CFI 7.2 ( / ], CFI 7.2 ( / ], CFI 7.2 ( / ], CFI 7.2 ( / ], CFI 7.2 ( / ] ( / ] ( / ] ( / ] ( / 9 ft 3 in. ] FM Approvals. All rights reserved. 10 of 19
11 ( / ] ( / ] ( / ] ( / +70/-98 ] ( / 14 ft 6 in. (4420 ] ( / (3660 ] ( / ] ( / ] ( / ] ( / +60/-84 ] ( / +75/-105 ] ( / +80/-112 ] FM Approvals. All rights reserved. 11 of 19
12 ( / +105/-147 ] ( / +130/ ft 0 in. (915 ] ( / (3660 ] ( / ] ( / ] ( / ] ( / ] ( / +65/-91 ] ( / +75/-105 ] ( / +95/-133 ] ( / +120/ ft 0 in. (915 ] ( / (3660 ] FM Approvals. All rights reserved. 12 of 19
13 ( / ] ( / ] ( / ] ( / ] ( / +60/-84 ] ( / +70/-98 ] ( / +90/-126 ] ( / +115/ ft 0 in. (915 ] ( / (3660 ] ( / ] ( / ] ( / ] FM Approvals. All rights reserved. 13 of 19
14 ( / ] ( / +60/-84 ] ( / +70/-98 ] ( / +90/-126 ] ( / +115/ ft 0 in. (915 ] ( / 15 ft 9 in. (4800 ] ( / 1 (4265 ] ( / (3660 ] ( / 11 ft 0 in. (3355 ] ( / ] ( / +60/-84 ] FM Approvals. All rights reserved. 14 of 19
15 ( / +70/-98 ] ( / +80/-112 ] ( / +95/-133 ] ( / 12 ft 9 in. (3885 ( / (3660 ] ( / 11 ft 0 in. (3355 ] ( / ] ( / ] ( / +60/-84 ] ( / +70/-98 ] FM Approvals. All rights reserved. 15 of 19
16 ( / +85/-119 ] ( / 12 ft 9 in. (3885 ] ( / 11 ft 0 in. (3355 ] ( / ] ( / ] ( / ] ( / +65/-91 ] ( / +80/-112 ] ( / 12 ft 9 in. (3885 ] ( / 11 ft 0 in. (3355 ] FM Approvals. All rights reserved. 16 of 19
17 ( / ] ( / ] ( / ] ( / +60/-84 ] ( / +75/-105 ] ( / 1 15 ft 9 in. (4800 in. (1.80] ( / 1 1 (4265 in. (1.80] ( / 1 (3660 in. (1.80] ( / 1 11 ft 0 in. (3355 in. (1.80] ( / 1 in. (1.80] ( / 1 +60/-84 in. (1.80] ( / 1 +70/-98 in. (1.80] ( / 1 +80/-112 in. (1.80] ( / 1 +95/-133 in. (1.80] ( / 1 12 ft 9 in. (3885 in. (1.80] FM Approvals. All rights reserved. 17 of 19
18 ( / 1 (3660 in. (1.80] ( / 1 11 ft 0 in. (3355 in. (1.80] ( / 1 in. (1.80] ( / 1 in. (1.80] ( / 1 +60/-84 in. (1.80] ( / 1 +70/-98 in. (1.80] ( / 1 +85/-119 in. (1.80] ( / 1 12 ft 9 in. (3885 in. (1.80] ( / 1 11 ft 0 in. (3355 in. (1.80] ( / 1 in. (1.80] ( / 1 in. (1.80] ( / 1 in. (1.80] ( / 1 +65/-91 in. (1.80] ( / 1 +80/-112 in. (1.80] Table tes: Panels rated for may be used in Zones H and NH. Panels rated for M-LM may be used in Zones HM, H and NH. Panels rated for M-LM (FL) may be used in Zones HM-LM (FL), HM-LM, H and NH. See below for installation details for specific exterior wall panels. CF-Flute, CF-Metl-Plank,, CF-7.2, CFI-Mesa,CFI-Light, CFI installed vertically or horizontally over steel structural members as indicated in the table above. - Clip Attachment Screws (stainless steel or coated carbon steel 1/4-14 HWH self drilling fasteners with type 3 points, 1/4-14, 1/4-20, 1/4-28 or HWH self drilling fasteners with type 5 points or #14-14 HWH self tapping fasteners with type AB, B or BP points through one U-Clip at each bearing in each panel side joint. - Clip Attachment Screws (stainless steel or coated carbon steel 1/4-14 HWH self drilling fasteners with type 3 points, 1/4-14, 1/4-20, 1/4-28 or HWH self drilling fasteners with type 5 points or #14-14 HWH self tapping fasteners with type AB, B or BP points through one U-Clip at each bearing in each panel side joint and one Fab-Lok fastener (10-4, 10-8 or suitable for the thickness of the structural member) or Bulb-tite Structural Blind Rivets (RV , RV , RV or RV suitable for the thickness of the structural member) per bearing through the structural member into the interior panel facer in. (265 ± 1.5 in. (38 from each female panel edge through holes predrilled with a 5 16in. (7.9 diameter drill bit. - Clip Attachment Screws (stainless steel or coated carbon steel 1/4-14 HWH self drilling fasteners with type 3 points, 1/4-14, 1/4-20, 1/4-28 or FM Approvals. All rights reserved. 18 of 19
19 12-24 HWH self drilling fasteners with type 5 points or #14-14 HWH self tapping fasteners with type AB, B or BP points) through one U-Clip at each bearing in each panel side joint and three Fab-Lok fasteners (10-4, 10-8 or suitable for the thickness of the structural member) or Bulb-tite Structural Blind Rivets (RV , RV , RV or RV suitable for the thickness of the structural member) per bearing through the structural member into the interior panel facer equally spaced [± 1.5 in. (38 ] between U-Clips through holes predrilled with a 5 16in. (7.9 diameter drill bit. CF-Flute, CF-Metl-Plank, CFI-Flute, Mesa & CFI-Metl-Plank - installed vertically or horizontally over steel structural members as indicated in the table above. - Panels through fastened to each steel support with Panel Attachment Screws with Sealing Washers 3 to 8 in. (75 to 200 long stainless steel or coated carbon steel fasteners with 3/8 in. (9.5 hex washer heads and 5/8 in. (16 diameter sealing washers; 1/4-14 HWH self drilling fasteners with type 3 points for minimum in. (1.8 ]steel supports, 1/4-14, 1/4-20, 1/4-28 or HWH self drilling fasteners with type 5 points for minimum 3/16 in. (4.75 steel supports or #14-14 HWH self tapping fasteners with type AB, B or BP points for minimum in. (1.8 ] steel supports through properly sized pilot holes) 8.4 in. (215 on center. CF 7.2 AND CFI installed vertically or horizontally over steel structural members as indicated in the table above. 1 - Panels through fastened to each steel support with Panel Attachment Screws with Sealing Washers (3 to 8 in. (75 to 200 long stainless steel or coated carbon steel fasteners with 3/8 in. (9.5 hex washer heads and 5/8 in. (16 diameter sealing washers; 1/4-14 HWH self drilling fasteners with type 3 points for minimum in. (1.8 ] steel supports, 1/4-14, 1/4-20, 1/4-28 or HWH self drilling fasteners with type 5 points for minimum 3/16 in. (4.75 steel supports or #14-14 HWH self tapping fasteners with type AB, B or BP points for minimum in. (1.8 ] steel supports through properly sized pilot holes) 7.2 in. (185 on center. - This product contains no urea-formaldehyde. - This product contains no CFC or HCFC. Company Name: Metl-Span LLC Company Address: 1497 N Kealy St, Lewisville, Texas 75057, USA Company Website: Green Product: Yes Primary of Work: 4881-Exterior Wall Systems Listing Country: United States of America Certification Type: FM Approved FM Approvals. All rights reserved. 19 of 19
20
21
22
Approval Standard for Class 1 Exterior Wall Systems
Approval Standard for Class 1 Exterior Wall Systems Class Number 4881 November 2007 2007 FM Approvals LLC. All rights reserved. Foreword The FM Approvals certification mark is intended to verify that the
TEST REPORT. Report No.: A9814.01 109 44. Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept
Architectural Testing TEST REPORT Report No.: A9814.01 109 44 Rendered to: BAMCO INC. Middlesex, New Jersey PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept AAMA 508 07, Voluntary Test Method
STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES
ROOFING APPLICATION STANDARD (RAS) No. 117 STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES Scope 1.1.
Nucor VR16 II TM Vertical Rib Standing Seam Roof System
Nucor VR16 II TM Vertical Rib Standing Seam Ro System www.nucorbuildingsystems.com Nucor VR16 II Vertical Rib Standing Seam Ro Perfect for the Marketplace The Nucor Building Systems VR16 II Ro Panel is
Residential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
Guidelines for Earthquake Bracing of Residential Water Heaters
Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)
PART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
ISO Types 1-6: Construction Code Descriptions
ISO 1 Frame (combustible walls and/or roof) Class 1B Buildings where the exterior walls are wood or other combustible materials, including construction where the combustible materials are combined with
DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 41 13 METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC
0 ICC ES Report ICC ES (800) 423 687 (62) 699 043 www.icc es.org 000 Most Widely Accepted and Trusted ESR 3422 Reissued 09/201 This report is subject to renewal 09/2016. DIVISION: 07 00 00 THERMAL AND
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590
Excerpts from the Canadian National Building Code (NBC)
Excerpts from the Canadian National Building Code (NBC) Reproduced here with Permission of the Copyright Owner, the National Research Council of Canada, Institute for Research in Construction. For more
PANELIZED HOME INSTALLATION GUIDELINE
PANELIZED HOME INSTALLATION GUIDELINE A typical home package will be constructed of Snap-N-Lock Insulated Panels clad with steel skins. 4" panels will be used for the walls, and 6" panels for the roof.
ICC-ES Evaluation Report
ICC-ES Evaluation Report ESR-2369 Reissued May 1, 2010 This report is subject to re-examination in one year. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council
HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES 101 Retrofits Required. Pursuant to Section 553.844 553.884, Florida Statutes, strengthening of existing site-built,
Connection Solutions
Connection Solutions DESIGN BUILD SYSTEM Connection Solutions for Cold formed Steel Construction Complies with; AS/NZS 4600:2005 AISI S100:2007 AS/NZ 1397 ASTM A653 DESIGN & BUILD SYSTEM FRAMECAD Construction
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
HORIZONTAL INSTALLATION
THERMO/SOLAR Žiar s.r.o. MANUAL FOR INSTALLATION PV SUPPORTING FRAMES HORIZONTAL INSTALLATION Technical alternation reserved A1410 1 12/2014 CONTENT ORD.NO. PAGE Mounting information 3 Mounting, flat roof
DuPont Tyvek Commercial Air Barrier Assemblies Exceed Air Barrier Association of America, ASHRAE 90.1
Building Science Bulletin DuPont Tyvek Commercial Air Barrier Assemblies Exceed Air Barrier Association of America, ASHRAE 90.1 and IECC Air Leakage Requirements When Tested in Accordance with ASTM E2357
Packaged Terminal Air Conditioner Wall Sleeve Installation
Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation
Fire Barrier Duct Wrap 15A
3 Fire Barrier Duct Wrap 15A Commerical Kitchen Grease Duct Fire Protection System Product Data and Installation Instructions Compliance 1998 Edition Complies with International Mechanical Code Complies
ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: NORSE, INC.
Architectural Testing ASTM E 1886 and ASTM E 1996 TEST REPORT Rendered to: NORSE, INC. SERIES/MODEL: Flush Mount/Surface Mount PRODUCT TYPE: Hurricane Shutter Fastening System This report contains in its
INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.
INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT. awipanels.com From freezing, sub-zero temperatures to Contents dry heat or high humidity, Mother Nature continually tests the limits of building envelopes. That's
TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"
2 TABLE OF CONTENTS SECTION 1: What is a Standing Seam Metal Roof PAGE 3 SECTION 2: Common Types of Standing Seam Metal Roofs..PAGE 5 SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE
Metal Roofing Practical Design
Metal Roofing Practical Design Metal Roofing Practical Design Learning Outcomes Minimum Requirements Design Resources Low Slope Metal Roofing Design Details Continuously Insulated (Ci) Systems Minimum
TZ WEDGE ANCHOR FOR CRACKED AND UNCRACKED CONCRETE
SECTION 2.2 PAGE 1 / 9 l DESCRIPTION UCAN TZ torque controlled mechanical expansion wedge anchors have a Category 1 classification. They are used to resist static, wind and seismic tension and shear loads
Guidelines for Earthquake Bracing Residential Water Heaters
Guidelines for Earthquake Bracing Residential Water Heaters Department of General Services Division of the State Architect In accordance with the Health and Safety Code Section 19215, the Division of the
There s a LYSAGHT walling solution to suit every Australian building. Walling Solutions 2PF300 PAGE 1
Walling Solutions There s a LYSAGHT walling solution to suit every Australian building. 2PF300 PAGE 1 LYSAGHT Walling Products Scope. Walling Design Maintenance PAGE 2 Materials and finishes Typical material
TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks 174.6 FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.
Pages identified with the NMBS Logo as shown above, have been produced by NMBS to assist specifiers and consumers in the application of New Millennium Building Systems Deck products. Pages identified with
Protecting Roofing Systems Against Windstorm Damage
Protecting Roofing Systems Against Windstorm Damage This brochure is made available for informational purposes only in support of the insurance relationship between FM Global and its clients. This information
THE DOW CHEMICAL COMPANY Issued: August 1, 2008 200 LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN 48674 (989) 638-8655 www.dowbuildingmaterials.
ICC EVALUATION SERVICE, INC. EvaluateP InformP Protect Los Angeles Business/Regional OfficeP 5360 Workman Mill RoadP Whittier, CA 90601 (562) 699-0543 phonep (562) 695-4694 fax DIVISION: Section: 6 WOOD
VA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD
SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board, vapor retarder and air and moisture barrrier. 1.2 RELATED WORK A. Installation
The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16.
The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16. Please refer to the publication in its entirety for complete details on this product
REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N
PLAN REVIEW FOR: PROJECT NAME: OWNER: ARCH/DESIGNER: ADDRESS: Ph/Fx: Plans Dated: E-mail: Sealed By: Estimated Project Cost - $ REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N
The Florida Building Code
Setting New Standards for Safety The Florida Building Code Florida Building Commission Florida Department of Community Affairs The Florida Building Code System The Florida Building Commission Florida Building
Advanced Wind Mitigation Methodologies Pt. 2 Online Retrofit Course. Section 1: Introduction
Advanced Wind Mitigation Methodologies Pt. 2 Online Retrofit Course Section 1: Introduction Slide 1: Advanced Wind Mitigation Methodologies Pt.2 Online Retrofit Course Slide 2: Welcome to Advanced Wind
Hilti, Inc. 5400 South 122 nd East Avenue Tulsa, OK 74146. 1-800-879-8000 www.hilti.com
Attached are page(s) from the 2014 Hilti North American Product Tech Guide. For complete details on this product, including data development, product specifications, general suitability, installation,
The better way to build TM. Installation Manual. EXTERIOR WALL SIPs
The better way to build TM Installation Manual EXTERIOR WALL SIPs July 2015 EXTERIOR WALL SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................
Hilti KWIK HUS-EZ I (KH-EZ I) Internally Threaded Carbon Steel Screw Anchor
Hilti KWIK HUS-EZ I (KH-EZ I) Internally Threaded Carbon Steel Screw Anchor Supplement to Hilti North American Product Technical Guide Volume 2: Anchor Fastening Technical Guide 2011 Edition 3.3. KWIK
TEST REPORT. Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana
Architectural Testing TEST REPORT Report No.: D0162.02-201-44 Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana PRODUCT TYPE: Pressure Equalized Rainscreen SERIES/MODEL: 4 mm Composite
Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide
Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3
Clad Direct Glaze Window Installation Instructions
Clad Direct Glaze Window Installation Instructions Sill flashing and sealing: 2. An overview of the proper flashing sequence is shown in figure 1. Please read entire installation instructions carefully
Basement Window Installation Guide Hopper and Sliding
Basement Window Installation Guide Hopper and Sliding americancraftsmanwindows.com Project Requirements: Installation must comply with all applicable building codes. Existing window frame, wall and weatherresistant
Owner's Manual & Assembly Instructions
Owner's Manual & Assembly Instructions PM01 BASE KIT Model No. FDN1014 717090311 CAUTION: SOME PARTS HAVE SHARP EDGES. CARE MUST BE TAKEN WHEN HANDLING THE VARIOUS PIECES TO AVOID A MISHAP. FOR SAFETY
Insurance Mitigation Factors for Homeowners Purchasing Garage Doors In Florida
Insurance Mitigation Factors for Homeowners Purchasing Garage In Florida The following questions and answers are intended to clarify the effect on insurance premiums for Florida homeowners when a new or
CONDENSATION IN REFRIDGERATED BUILDINGS
CONDENSATION IN REFRIDGERATED BUILDINGS By: Steve Salisbury Nov. 10, 2010 (revised Nov. 14, 2013) Introduction The following discussion reviews the basic causes of condensation in refrigerated buildings
Design of Cold-Formed Steel Shear Walls
DESIGN GUIDE 2 Design of Cold-Formed Steel Shear Walls March 1998 The following publication was developed by R.L. Brockenbrough & Associates for the American Iron and Steel Institute (AISI), In the production
0845 0098 980 www.nicholsonsts.com
0845 0098 980 www.nicholsonsts.com ROOFTRAK The IFP is revolutionising the way we fix things to roofs. Technical Director of a leading UK roofing system manufacturer The ROOFTRAK-IFP A revolutionary solution
Window Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for
Technical handbook Panel Anchoring System
1 Basic principles of sandwich panels 3 Design conditions 4 Basic placement of anchors and pins 9 Large elements (muliple rows) 10 Small elements (two rows) 10 Turned elements 10 Slender elements 10 Cantilevering
Wind Mitigation Inspection
[email protected] Tampa Bay Area: SW & Central Florida: (813) 368-6407 (239) 896-3986 Wind Mitigation Inspection VonHaase, Dale 4585 Bowen Bayou Road Sanibel, FL 33957 5/6/2013 Note to Policyholder:
H-Stud Area Separation Wall System
12 TH EDITION 09 21 16.33/NGC H-Stud Area Separation Wall System 09 21 16.33 139 H-STUD AREA SEPARATION WALL SYSTEM The fire-protection of gypsum-based Area Separation Walls is demonstrated in dramatic
Discipline: Structural Issued 04-26-06
California Department of General Services. Division of the State Architect. Product Acceptance Report STRUCTURAL SHEAR PANEL SURE-BOARD SERIES 200 PANELS PA-132 Discipline: Structural Issued 04-26-06 This
CONSTRUCTION DETAILS & LOAD DESIGN CHARTS
Office and Production 126 New Pace Rd., PO Box 279 Newcomerstown, OH 43832 1-800-446-2188, Fax: 740-498-4184 www.buildwithsips.com CONSTRUCTION DETAILS & LOAD DESIGN CHARTS Table of Contents Description
Canvas Office Landscape Wall Strip Installation and Disassembly for Recycling Instructions
Y Parts Included: Canvas Office Landscape Wall Strip Installation and Disassembly for Recycling Instructions Tools Required: Power Driver Drill Bit (Determined by fastener) Driver Bit (Determined by fastener)
STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM
Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally
APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET
Environmental Protection and Growth Management Department PERMITTING, LICENSING AND CONSUMER PROTECTION DIVISION 1 N. University Drive, Box #302 Plantation, Florida 33324 954-765-4400 www.broward.org/permittingandlicensing
Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY
Insulation for Above the Deck WALL SPECIALTY PRODUCT DESCRIPTION Rmax Re-Cover Board-3 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (polyiso) foam core bonded
How to secure your property after a disaster
How to secure your property after a disaster The Red Guide to Recovery HOuse secured properly Board-Up of Windows, Doors and Roof Hole. Lot secured with Perimeter Fencing. Fires, floods, tornadoes, hurricanes,
COMMONLY USED RESIDENTIAL BUILDING CODES
COMMONLY USED RESIDENTIAL BUILDING CODES INTERNATIONAL RESIDENTIAL CODE (2009) form revised 5/10 FOUNDATION 1. DESIGN OF FORMWORK. Section 1906.1 IBC 2009, Section R404.1.2.3.6 IRC 2009, ACI 318 Section
Roof insulations must perform the basic function of helping to control fluctuations in building interior temperature
Thermal Values Roof insulations must perform the basic function of helping to control fluctuations in building interior temperature relative to changing exterior temperatures. By reducing interior temperature
K2 STONE NATURAL VENEER
INTRODUCTION WHAT IS K2 NATURAL THINSTONE VENEER? Natural K2 Stone veneer is real stone, cut 1 inch thick, making it light enough to be installed as a veneer. Sometimes referred to as thin veneer, thin
Report on. Wind Resistance of Signs supported by. Glass Fiber Reinforced Concrete (GFRC) Pillars
Report on Wind Resistance of Signs supported by Glass Fiber Reinforced Concrete (GFRC) Pillars Prepared for US Sign and Fabrication Corporation January, 2006 SUMMARY This study found the attachment of
Standard from CSI Part Section Format. 06212 For Wood Framing 05160 For Metal Framing 09226 For Gypsum Sheathing
Standard from CSI Part Section Format. 06212 For Wood Framing 05160 For Metal Framing 09226 For Gypsum Sheathing Specifications for SURE-BOARD Series 200 and 200W Panel for shear PART 1.0 GENERAL 1.01
REPORT NUMBER: 100900226COQ-003 ORIGINAL ISSUE DATE: July 19, 2013
REPORT NUMBER: 100900226COQ-003 ORIGINAL ISSUE DATE: July 19, 2013 TEST REPORT EVALUATION CENTER INTERTEK TESTING SERVICES NA LTD. 1500 BRIGANTINE DRIVE COQUITLAM, BC V3K 7C1 CANADA RENDERED TO PHOENIX
GYPSUM AREA SEPARATION FIREWALLS GA-620-2011
GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GA-620-2011 Copyright 2011 Gypsum Association All rights reserved. Printed in U.S.A. Characteristics, properties, or performance of materials or systems herein
TechPractices: Home Front Homes:
TechPractices: Home Front Homes: PATH's Technologies in Practice are large scale housing projects throughout the U.S. where innovative technologies are being installed and used. Information is presented
SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION
SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION As of October 1, 2007, this mitigation form must be submitted as part of the roofing permit application package. Secondary water barrier (if applicable)
Hilti, Inc. 5400 South 122 nd East Avenue Tulsa, OK 74146. 1-800-879-8000 www.hilti.com
Attached are page(s) from the 2014 Hilti North American Product Tech Guide. For complete details on this product, including data development, product specifications, general suitability, installation,
ROOF FLASHING SPRINGLOK FLASHING SYSTEM FEATURES & BENEFITS PRODUCT DESCRIPTION
SPRINGLOK SYSTEM PRODUCT DESCRIPTION FEATURES & BENEFITS Fry Reglet offers five flashing systems, each tailored for a particular type of substrate so you can get exactly what you need. SM Surface mounted
Fire Resistance of Brick Masonry
TECHNICAL NOTES on Brick Construction 1850 Centennial Park Drive, Reston, Virginia 20191 www.gobrick.com 703-620-0010 Fire Resistance of Brick Masonry 16 March 2008 Abstract: This Technical Note presents
CH. 2 LOADS ON BUILDINGS
CH. 2 LOADS ON BUILDINGS GRAVITY LOADS Dead loads Vertical loads due to weight of building and any permanent equipment Dead loads of structural elements cannot be readily determined b/c weight depends
ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT. Rendered to: BEKAERT SPECIALTY FILMS, LLC
ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT Rendered to: BEKAERT SPECIALTY FILMS, LLC SERIES/MODEL: Panorama 8-mil Film PRODUCT TYPE: Fixed Window with Applied Film This
first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel
first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel What is GigaCrete GigaCrete is a family of products based on low carbon footprint Green ceramic binders
All-Season Sunroom Sliding Glass Door Installation Instructions
ASRESGD-08 All-Season Sunroom Sliding Glass Door Installation Instructions Panel Frame Door Frame Left Side Foam Insulator IE241 H Bar Assembly Door Frame Top Track Panel Frame Door Frame Right Side Stationary
How To Test For An Architectural Test
Architectural Testing ASTM E 1886 and ASTM E 1996 TEST REPORT Rendered to: CORAL ARCHITECTURAL PRODUCTS SERIES/MODEL: PW 256 with Door Openings PRODUCT TYPE: Aluminum Impact Resistant Curtain Wall System
Mark Cramer Inspection Services, Inc.
Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction
2.18 INTERIOR & EXTERIOR FINISHES 2.18.1 VAPOR & AIR BARRIERS
2.18 INTERIOR & EXTERIOR FINISHES 2.18.1 VAPOR & AIR BARRIERS The LOGIX wall assembly has no need for an additional vapor barrier, the solid concrete core covered with the low permeance EPS (Type II) foam
INSTALLATION OF A BAY WINDOW
INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening
Submittal Information
Wedge SPECIFIED FOR ANCHORAGE INTO CONCRETE Wedge anchs feature a stainless steel expansion clip, threaded stud body, nut and washer. Anch bodies are made of plated carbon steel, hot-dipped galvanized
How To Replace A Reverse Osmosis Water Tank
ALL MODELS REVERSE OSMOSIS WITH NONAIRGAP FAUCET 1. Read all instructions carefully before starting installation. 2. Find the cold water line beneath your sink. The cold water is typically on the right.
Residential Decks. Planning and Development Services Department
Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email: [email protected] Planning and Development Services Department Residential Decks
Brick Veneer Construction
Brick Veneer Construction Check list of suggested tools & support items Claw hammer Tape measure 3/4" [19 or 20] Wood chisel Wood or plastic shims Pry bar Utility knife Caulking and caulking gun Power
DELTA PT. Calculable Extra Performance
DELTA PT Calculable Extra Performance DELTA PT The Screw for Thermoplastics Optimal material flow Superior vibration resistance High torsional strength and tensile strength Calculable performance The Fastener
FIRESTOPPING & SMOKE SEALS
SPECIFICATION SECTION 07 84 00 FIRESTOPPING & SMOKE SEALS 1 GENERAL 1.1 SECTION INCLUDES 1.1.1 Comply with Division 1, General Requirements and Documents referred to therein. 1.1.2 It is the intent of
Introduction...COMB-2 Design Considerations and Examples...COMB-3
SECTION DIRECTORY General Information Introduction...COMB-2 Design Considerations and Examples...COMB-3 Combination Assembly Recommendations and Limitations Composite Configurations...COMB-4 Typical Sealant
AA Solar and Sun Power Plus
AA Solar and Sun Power Plus www.aasolar.co.nz www.sunpowerplus.co.nz -1- Contents Chapter Title Page 1 General information 3 2 Safety and Installer Responsibilities 4 3 Technical Specifications 5 4 Tools
CF INSULATED METAL WALL PANEL INSTALLATION GUIDE PIONEERING INSULATED METAL PANEL TECHNOLOGY
CF INSULATED METAL WALL PANEL INSTALLATION GUIDE PIONEERING INSULATED METAL PANEL TECHNOLOGY PIONEERING INSULATED METAL PANEL TECHNOLOGY CONTENTS INTRODUCTION....................................... 2 RESPONSIBILITIES
MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Report No.: B8049.01-401-18. Rendered to: AMERICAN PRODUCTS, INC Tampa, Florida
Architectural Testing MIAMI-DADE COUNTY PERFORMANCE TEST REPORT Report No.: B8049.01-401-18 Rendered to: AMERICAN PRODUCTS, INC Tampa, Florida PRODUCT TYPE: Aluminum Storefront with Double Doors SERIES/MODEL:
PERIMETER FLASHING. Table of Contents
FM Global Property Loss Prevention Data Sheets 1-49 February 1985 Revised September 2000 Page1of25 PERIMETER FLASHING Table of Contents Page 1.0 SCOPE... 3 1.1 Changes... 3 2.0 LOSS PREVENTION RECOMMENDATIONS...
foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.
Skylight Installation Instructions This document provides instruction and guidelines for installation of both curb mount (CM) and self flashing (SF) unit skylights on flat, pitched (> or equal to 3/12
Commercial Building Valuation Report
INSURED University of Houston - Victoria Effective Date: Expiration Date: Cost as of: 09/2010 BUILDING 1 217 - University Center 77901 Location Adjustments Climatic Region: High Wind Region: Seismic Zone:
TEST PROCEDURE FOR FIELD WITHDRAWAL RESISTANCE TESTING
TESTING APPLICATION STANDARD (TAS) No. 105-98 TEST PROCEDURE FOR FIELD WITHDRAWAL RESISTANCE TESTING 1. Scope 1.1 This Testing Application Standard (TAS) covers procedures for withdrawal resistance testing
necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the
Chapter 7 PLUMBING AND ELECTRICAL 7.1 Introduction to Plumbing and Electrical Consideration of support services such as plumbing and electrical systems from the preliminary schematics phase through final
Design No. P736 September 26, 2003. Restrained Assembly Ratings 1, 1-1/2 or 2 Hr. (See Items 3, 7 and 8A)
Design No. P736 September 26, 2003 Restrained Ratings 1, 1-1/2 or 2 Hr (See Items 3, 7 and 8A) Ratings 1, 1-1/2 or 2 Hr (See Items 3, 7 and 8A) Beam Ratings 1, 1-1/2 or 2 Hr (See Items 7 and 8A) 1. Beam
Premier & Deluxe 3-Season Room Sliding Glass Door
DTSSGD-11 Premier & Deluxe 3-Season Room Sliding Glass Door Installation Instructions Screen Door Seal Left Side Track Top Track Assembly Right Side Track Right Side Trim Sliding Glass Door Sliding Screen
March 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023
Specifications Preformed Metal Wall and Roof Panels Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023 Section 07410 Preformed Metal Wall and Roof Panels Structural
PERFORMANCE TEST REPORT. Rendered to: BAMCO INC. PRODUCT TYPE: ACM Wall Panel Systems
PERFORMANCE TEST REPORT Rendered to: BAMCO INC. PRODUCT TYPE: ACM Wall Panel Systems Summary of Results Title Test Specimen #1 Test Specimen #2 Air Infiltration
SUNPAL Multiwall Polycarbonate Standing-Seam Architectural System
SUNPAL Multiwall Polycarbonate Standing-Seam Architectural System Technical Guide Creating New Solutions for over 40 Years www.palram.com Contents Page Introduction 3 Panel Specification 4 Colors and Solar
INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP
INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES Interpretations of the FTP CONTENTS FTP1 Adhesives used in A or B class divisions (FTP Code 3.1, Res A.754 para. 3.2.3) June 2000 FTP2 Pipe and duct
