X-Ray Diffraction HOW IT WORKS WHAT IT CAN AND WHAT IT CANNOT TELL US. Hanno zur Loye



Similar documents
Crystal Structure Determination I

Introduction to Powder X-Ray Diffraction History Basic Principles

Experiment: Crystal Structure Analysis in Engineering Materials

Introduction to X-Ray Powder Diffraction Data Analysis

X-ray Diffraction (XRD)

Structure Factors

Chapters 2 and 6 in Waseda. Lesson 8 Lattice Planes and Directions. Suggested Reading

POWDER X-RAY DIFFRACTION: STRUCTURAL DETERMINATION OF ALKALI HALIDE SALTS

X-ray Powder Diffraction Pattern Indexing for Pharmaceutical Applications

Relevant Reading for this Lecture... Pages

LMB Crystallography Course, Crystals, Symmetry and Space Groups Andrew Leslie

Chapter 7: Basics of X-ray Diffraction

Crystal Structure of High Temperature Superconductors. Marie Nelson East Orange Campus High School NJIT Professor: Trevor Tyson

Powder diffraction and synchrotron radiation

Lec 17: Dislocation Geometry and Fabric Production 1. Crystal Geometry

X-ray diffraction techniques for thin films

X-ray Diffraction and EBSD

X-Ray Diffraction: A Comprehensive Explanation for Multipurpose Research

X-ray thin-film measurement techniques

Chapter types of materials- amorphous, crystalline, and polycrystalline. 5. Same as #3 for the ceramic and diamond crystal structures.

Diffraction Course Series 2015

X-ray diffraction in polymer science

Chapter Outline. How do atoms arrange themselves to form solids?

Generation of X-Rays (prepared by James R. Connolly, for EPS , Introduction to X-Ray Powder Diffraction, Spring 2005)

Solid State Theory Physics 545

rotation,, axis of rotoinversion,, center of symmetry, and mirror planes can be

PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS

DIEGO TONINI MORPHOLOGY OF NIOBIUM FILMS SPUTTERED AT DIFFERENT TARGET SUBSTRATE ANGLE

Basics of X-ray diffraction: From symmetry to structure determination

Glancing XRD and XRF for the Study of Texture Development in SmCo Based Films Sputtered Onto Silicon Substrates

Phase Characterization of TiO 2 Powder by XRD and TEM

Theory of X-Ray Diffraction. Kingshuk Majumdar

Crystalline Structures Crystal Lattice Structures

ME 612 Metal Forming and Theory of Plasticity. 1. Introduction

This is an author-deposited version published in: Handle ID:.

Laue lens for Nuclear Medicine

Crystal Optics of Visible Light

X-ray Diffraction Techniques for Structural Determination of Amorphous Materials

Polarization Dependence in X-ray Spectroscopy and Scattering. S P Collins et al Diamond Light Source UK

X-RAY DIFFRACTION IMAGING AS A TOOL OF MESOSTRUCTURE ANALYSIS

Chapter Outline Dislocations and Strengthening Mechanisms

Ajit Kumar Patra (Autor) Crystal structure, anisotropy and spin reorientation transition of highly coercive, epitaxial Pr-Co films

Diffraction of Laser Light

USING MATLAB FOR MATERIALS DESIGN: DESCRIBING GRAIN ORIENTATIONS IN METALS Claes Olsson, PhD - Docent / Sandvik Materials Technology

Supplementary Material (ESI) for Chemical Communications This journal is (c) The Royal Society of Chemistry 2009

We shall first regard the dense sphere packing model Draw a two dimensional pattern of dense packing spheres. Identify the twodimensional

LECTURE SUMMARY September 30th 2009

The atomic packing factor is defined as the ratio of sphere volume to the total unit cell volume, or APF = V S V C. = 2(sphere volume) = 2 = V C = 4R

Data Mining Tools. Sorted Displays Histograms SIeve

Properties of Electrons, their Interactions with Matter and Applications in Electron Microscopy

PHYSIOLOGY AND MAINTENANCE Vol. II - On The Determination of Enzyme Structure, Function, and Mechanism - Glumoff T.

Supporting Information

Development of Optical Wave Microphone Measuring Sound Waves with No Diaphragm

Chapter 8. Low energy ion scattering study of Fe 4 N on Cu(100)

DOING PHYSICS WITH MATLAB COMPUTATIONAL OPTICS RAYLEIGH-SOMMERFELD DIFFRACTION INTEGRAL OF THE FIRST KIND

Chapter 3: Structure of Metals and Ceramics. Chapter 3: Structure of Metals and Ceramics. Learning Objective

In the previous presentation, we discussed how x-rays were discovered and how they are generated at the atomic level. Today we will begin the

Jorge E. Fernández Laboratory of Montecuccolino (DIENCA), Alma Mater Studiorum University of Bologna, via dei Colli, 16, Bologna, Italy

Polarization of Light

Blackbody Radiation References INTRODUCTION

Raman spectroscopy Lecture

X-ray Production. Target Interactions. Principles of Imaging Science I (RAD119) X-ray Production & Emission

The Phenomenon of Photoelectric Emission:

Advanced Physics Laboratory. XRF X-Ray Fluorescence: Energy-Dispersive analysis (EDXRF)

Publication of small-unit-cell structures in Acta Crystallographica Michael Hoyland ECM28 University of Warwick, 2013

Guide to Understanding X-ray Crystallography

Fundamentals of grain boundaries and grain boundary migration

CRYSTALLINE SOLIDS IN 3D

6) How wide must a narrow slit be if the first diffraction minimum occurs at ±12 with laser light of 633 nm?

A NATIONAL MEASUREMENT GOOD PRACTICE GUIDE. No. 52. Determination of Residual Stresses by X-ray Diffraction - Issue 2

Preview of Period 3: Electromagnetic Waves Radiant Energy II

WAVELENGTH OF LIGHT - DIFFRACTION GRATING

A program for phase identification using diffractograms obtained from TEM structure images

Each grain is a single crystal with a specific orientation. Imperfections

Lectures about XRF (X-Ray Fluorescence)

Symmetry-operations, point groups, space groups and crystal structure

Waves - Transverse and Longitudinal Waves

Interference. Physics 102 Workshop #3. General Instructions

Chem 106 Thursday Feb. 3, 2011

The Structure of solids.

Geometry of Minerals

Flame Tests & Electron Configuration

Introduction to microstructure

" {h k l } lop x odl. ORxOS. (2) Determine the interplanar angle between these two planes:

SHIMADZU XRD-7000 X-RAY DIFFRACTOMETER. The Fridge. Operating Instructions

Atomic Force Microscope and Magnetic Force Microscope Background Information

PHYA2. General Certificate of Education Advanced Subsidiary Examination June Mechanics, Materials and Waves

RAPIDLY SOLIDIFIED COPPER ALLOYS RIBBONS

In vitro examination of human teeth using ultrasound and X-ray diffraction

Processing Data with rsmap3d Software Services Group Advanced Photon Source Argonne National Laboratory

Molecular Graphics What?

Chapter 1 Diffraction and the X-Ray Powder Diffractometer 1.1 Diffraction Introduction to Diffraction

Crystal Structure Determination of 5,6-Dibromoacenaphthene from X-ray Powder Diffraction Data

Lenses and Apertures of A TEM

X-RAY DETERMINATION OF THE STRUCTURE OF GLASS*

Electron density is complex!

Lösungen Übung Verformung

Transcription:

X-Ray Diffraction HOW IT WORKS WHAT IT CAN AND WHAT IT CANNOT TELL US Hanno zur Loye

X-rays are electromagnetic radiation of wavelength about 1 Å (10-10 m), which is about the same size as an atom. The discovery of X-rays in 1895 enabled scientists to probe crystalline structure at the atomic level. X-ray diffraction has been in use in two main areas, for the fingerprint characterization of crystalline materials and the determination of their structure. Each crystalline solid has its unique characteristic X-ray powder pattern which may be used as a "fingerprint" for its identification. Once the material has been identified, X-ray crystallography may be used to determine its structure, i.e. how the atoms pack together in the crystalline state and what the interatomic distance and angle are etc. X-ray diffraction is one of the most important characterization tools used in solid state chemistry and materials science. We can determine the size and the shape of the unit cell for any compound most easily using X-ray diffraction.

X-ray Diffraction Structural Analysis X-ray diffraction provides most definitive structural information Interatomic distances and bond angles X-rays To provide information about structures we need to probe atomic distances - this requires a probe wavelength of 1 x 10-10 m ~Angstroms

Production of X-rays X-rays are produced by bombarding a metal target (Cu, Mo usually) with a beam of electrons emitted from a hot filament (often tungsten). The incident beam will ionize electrons from the K-shell (1s) of the target atom and X-rays are emitted as the resultant vacancies are filled by electrons dropping down from the L (2P) or M (3p) levels. This gives rise to K a and K b lines.

X-rays Cu, Mo e - 20-50 kv target 3p M electromagnetic radiation 2p L 1s K Cu K α = 1.5418 Å Mo K α = 0.7107 Å

X-ray Generation Broad background is called Bremsstrahlung. Electrons are slowed down and loose energy in the form of X-rays

X-ray Production As the atomic number Z of the target element increases, the energy of the characteristic emission increases and the wavelength decreases. Moseley s Law (c/l) 1/2 Z Cu Mo Ka = 1.54178 Å Ka = 0.71069 Å We can select a monochromatic beam of one wavelength by: Crystal monochromator Bragg equation Filter - use element (Z-1) or (Z-2), i.e. Ni for Copper and Zr for Molybdenum.

X-ray Generation

Brookhaven National Synchrotron Light Source

Single Crystal Diffraction A single crystal at random orientations and its corresponding diffraction pattern. Just as the crystal is rotated by a random angle, the diffraction pattern calculated for this crystal is rotated by the same angle

A 'powder' composed from 4 single crystals in random orientation (left) and the corresponding diffraction pattern (middle). The individual diffraction patterns plotted in the same color as the corresponding crystal start to add up to rings of reflections. With just four reflection its difficult though to recognize the rings. The right image shows a diffraction pattern of 40 single crystal grains (black). The colored spots are the peaks from the 4 grain 'powder' shown in the middle image.

As we have more grains, the diffraction pattern looks more and more continuous and we get the expected powder pattern shown on the left.

Diffraction from several randomly oriented single crystals (powder) Diffraction from one single crystal Sample of hundreds of randomly oriented single crystals (powder) and film used to collect the data.

Our XRD instruments

Crystal Systems Axis Axis Angles 1 Cubic A = B = C α = β = γ = 90 2 Tetragonal A = B C α = β = γ = 90 3 Orthorhombic A B C α = β = γ = 90 4a Hexagonal A = B C α = β = 90, γ = 120 4b Rhombohedral A = B = C α = β = γ 90 < 120 5 Monoclinic A B C α = γ = 90, β > 90 6 Triclinic A B C α β γ 90 The higher the symmetry, the easier it is to index the pattern and the fewer lines there are in the pattern.

Miller Indices c/3 O a/2 a b c The origin is 0, 0, 0 If we drew a third plane, it would pass through the origin. (1 0 0) (2 0 0) (3 0 0) The plane cuts the x-axis at a/2, the b-axis at b, and the c-axis at c/3. The the reciprocals of the fractions, (2 1 3), which are the miller indices. A plane that is parallel to an axis will intersect that axis at infinity. One over infinity = 0. I.e. the (100) plane. Parallel to b and c and intersects a at 1.

The Bragg Equation Reflection of X-rays from two planes of atoms in a solid. x = dsinθ The path difference between two waves: 2 x wavelength = 2dsin(theta) Bragg Equation: nλ = 2dsinθ

d-spacing in different crystal systems Cubic Tetragonal Orthorhombic Hexagonal Monoclinic Triclinic - 1 d = h 2 + k 2 + l 2 2 a 2 1 d 2 = h 2 + k 2 a 2 + l2 c 2 1 d 2 = h 2 a 2 + k 2 b 2 + 1 d 2 = 4 3 1 d = 1 2 sin 2 β l2 c 2 h 2 + hk + k 2 + a 2 l2 c 2 h 2 a + k 2 sin 2 β + l2 2 b 2 c 2hlcosβ 2 ac

Diffraction pattern Intensity (I) is the total area under a peak I 2θ (deg)

Indexing Patterns Indexing is the process of determining the unit cell dimensions from the peak positions Manual indexing (time consuming...but still useful) Pattern matching/auto indexing (JADE or other computer based indexing software)

Cubic pattern

Relationship between diffraction peaks, miller indices and lattice spacings Simple cubic material a = 5.0 Å hkl d(å) 2Θ 100 5.00 17.72 110 3.54 25.15 111 2.89 30.94 Use 1 = h 2 + k 2 +l 2, and nλ = 2dsinΘ d 2 a 2 b 2 c 2 1 d = h 2 + k 2 + l 2 2 a 2 Bragg Equation: nλ = 2dsinθ How many lattice planes are possible? How many d-spacings? The number is large but finite. nλ = 2dsinθ so if theta = 180, then d = λ/2. For Cu radiation that means that we can only see d-spacings down to 0.77 Å for Mo radiation, down to about 0.35 Å

Tetragonal pattern 1 d 2 = h 2 + k 2 a 2 + l2 c 2 sin 2 θ = λ2 4 [ ] h 2 +k 2 + l 2 a 2 c 2

Orthorhombic a b c, all angles are 90 Multiplicity is further decreased as the symmetry decreases. 1 d 2 = h 2 a 2 + k 2 b 2 + l2 c 2 sin2 θ = λ2 4 [ h 2 + k 2 + l 2 ] a 2 b 2 c 2

Systematic Absences Cesium Metal 2πn Body Centered Cubic Structure c c' c c' c a = 2πn a = 2πn c' c' c c c In order to see diffraction from the (100) plane, the phase difference must be a multiple of 2p. However, the c and c planes are out of phase. Therefore - cancellation of the diffracted peak. The (200) plane, however, does not have this problem.

What Information Do We Get or Can We Get From Powder X-ray Diffraction Lattice parameters Phase identity Phase purity Crystallinity Crystal structure Percent phase composition

What Information Do We NOT Get From Powder X-ray Diffraction Elemental analysis - How much lithium is in this sample? Is there iron in this sample What elements are in this sample Tell me what this sample is???? Unless you know something about this sample, powder XRD won t have answers!!!

Powder Preparation It needs to be a powder It needs to be a pure powder Its nice to have about 1/2 g of sample, but one can work with less The powder needs to be packed tightly in the sample holder. Lose powders will give poor intensities.

Data Collection The scattering intensity drops as 1/2(1+cos 2 2θ) This means that you don t get much intensity past 70 2θ. A good range is 10-70 2θ. How long should you collect (time per step)? Depends on what you want to do! Routine analysis may only take 30-60 min. Data for Rietveld analysis may take 12-18 hours to collect

Rietveld Refinement employs a least squares matching algorithm refinement based on sample parameters and instrumental parameters

Data Analysis If you are trying to confirm that you have made a known material, do a search/match using the JCPDS data base. They have about 100,000 patterns on file. For a new material, you need to index the pattern. Unit cell, lattice parameters and symmetry.

Data Bases

Preferred Orientation The top image shows 200 random crystallites. The bottom picture shows 200 oriented crystallites. Despite the identical number of reflections,several powder lines are completely missing and the intensity of other lines is very misleading. Preferred orientation can substantially alter the appearance of the powder pattern. It is a serious problem in experimental powder diffraction.

Structure Refinement: The Rietveld Method