SHIMADZU XRD-7000 X-RAY DIFFRACTOMETER. The Fridge. Operating Instructions
|
|
|
- George Butler
- 9 years ago
- Views:
Transcription
1 The Fridge Operating Instructions
2 Table of Contents Introduction 1 RADIATION SAFETY i 5 DATA ANALYSIS Processing Data 15 Analyzing Data 17 Interactions of X-rays with Matter 2 Radiation Sources in the X-ray Diffraction Laboratory 2 Working Safely with X-rays 3 2 BACKGROUND Background Information 4 X-ray Powder Diffraction 4 The Conventional Powder Diffractometer 6 References 7 3 SAMPLE PREPARATION Preparation of Powder Samples 8 Preparation of Solid Samples 8 4 INSTRUMENT OPERATION Instrument Startup 9 Sample Loading 9 System Parameters Setup 10 Test Conditions Setup 11 Testing 13 Cleanup 14 Hardware Shutdown 14 1
3 Introduction i T he Shimadzu XRD-7000 Maxima is a state-of-the-art, multipurpose x-ray diffraction system that is optimized for powder diffraction studies of crystalline materials. The system is outfitted with a high-precision theta-theta goniometer (this is good) and a large sample stage. The software system includes a powerful search/match tool and the full International Center for Diffraction Data (ICDD) reference database of over 148,000 material phases. Many hardware upgrades environmental chambers, fiber analysis fixtures, automatic sample loaders, etc. and software upgrades are available for the XRD-7000 system. When some of you graduate, start companies, get rich, and throw some money back at Olin, we may be able to afford a few of the cool upgrades. 1
4 Radiation Safety 1,2 1 X -rays produced by the diffractometer pose a very real danger. Human tissue can be severely damaged if exposed to the x-rays used in x-ray diffraction. Long-term, chronic exposures at moderate levels can directly cause a variety of skin disorders, and chronic relatively low- level exposures may be a factor resulting in increased cancer risk in exposed personnel. Although modern XRD equipment includes safeguards designed to minimize or eliminate radiation in the work environment, an awareness of the dangers of radiation exposure and associated safety issues is required for anyone using the x-ray diffractometer. Interaction of X-Rays with Matter X-rays are a type of electromagnetic radiation that interacts with matter. That interaction takes place as either absorption (transfer of energy from the X-ray photon to the absorbing material) or scattering (in which the X-ray photon is redirected by interaction with the scattering material). The process of scattering is primary in producing diffraction data from test specimens, but both processes result in the production of a variety of potentially damaging secondary radiation that can produce significant short- and long-term health effects in the event of exposure of human tissue. The X-rays produced for diffraction analysis consist of characteristic radiation dependent on the anode target plus the continuous spectrum. Recall that the energy of X-rays and their wavelength are inversely proportional (higher energy = lower wavelength), and that the continuous spectrum minimum wavelength decreases as the accelerating voltage (kv) of the X-ray source increases. Also important to understand is that an increase in filament current (ma) and kv (beyond the minimum value required to produce characteristic radiation for the target) will result in an increase in the intensity of the generated X-rays but will not change their energy. Radiation Sources in the X-Ray Diffraction Laboratory The x-ray diffractometer is a source of very intense radiation, and exposure of any part of the body to the primary beam can deliver hundreds of times the maximum permissible yearly dose in a second, and an hour of exposure to the diffracted beam can result in a year s worth of permissible exposure. Whereas a primary beam exposure will produce noticeable skin damage very quickly, a diffracted beam exposure might not be physically noticed at all. 1 University of New Mexico, Department of Earth and Planetary Sciences 2 R. Jenkins and D. J. Haas (Philips Electronic Instruments), Hazards in the Use of X-Ray Analytical Instrumentation, X-Ray Spectrometry, Vol. 2, No. 3, July
5 Working Safely with X-rays It is imperative that anyone working with the x-ray diffractometer be properly trained and knowledgeable of its use in order to prevent injuries. If you do not feel you are properly trained to use the diffractometer, seek appropriate assistance from a competent and experienced user. To minimize (and hopefully eliminate) the likelihood of exposed to radiation in the laboratory, our x-ray diffractometer includes many safety-related features, including Complete shielding of the X-ray source and diffracted beam such that all radiation is contained within an enclosed area. Fail-safe safety interlocks installed on the x-ray chamber that prevent accidental opening of the chamber door. If the door is forced open, the X-ray source is turned off. The x-ray source will not operate if the door is open. A fail-safe indicator light should be present which is illuminated when the x-ray source is turned on. Sealed openings of the chamber to eliminate any possible leakage. Under no circumstances should anyone attempt to override any of the safety features of the x-ray diffractometer. The system should be checked for leakage periodically with the system at operating conditions using properly calibrated survey equipment. The system should also be checked if any of the following conditions exist: Any change in the components of the system (with the exception of minor components such as scattering and receiving slits). Prior to and after any maintenance requiring the disassembly or removal of a component in the system Anytime a visual inspection of the system reveals an abnormal condition. For routine operations of modern X-ray powder diffractometers, the radiation exposure in routine operations should be virtually nonexistent. 3
6 Background Information 2 NOTE: The following background text is taken directly or adapted from the Diffraction Methods section of ASM Handbook, Volume 10 Materials Characterization. X-ray diffraction techniques are some of the most useful in the characterization of crystalline materials, such as metals, intermetallics, ceramics, minerals, polymers, plastics, or other inorganic or organic compounds. X-ray diffraction techniques can be used to identify the phases present in samples from raw starting materials to finished product and to provide information on the physical state of the sample, such as grain size, texture, and crystal perfection. Most x-ray diffraction techniques are rapid and nondestructive; some instruments are portable and can be transported to the sample. The sample may be as small as an airborne dust particle or as large as an airplane wing. In general, x-ray analysis is restricted to crystalline materials, although some information may be obtained on amorphous solids and liquids. XRD samples are acceptable in many forms, depending on the availability of the material and the type of analysis to be performed. Single crystals from a few microns to a few inches in diameter or loose or consolidated aggregate of many small crystals can be used. Although the overall size of the sample may be large, the actual area of the sample examined in a given experiment rarely exceeds 1 cm 2. The type of information obtained from x-ray diffraction studies ranges from sample composition to details of the crystal structure or the state of orientation of the crystallites. Phase identification can be conducted on virtually all single crystal or powder samples. Also useful are measurements of the physical state of a sample that detect differences from the ideal crystal (presence of defects, strain, etc.). X-ray Powder Diffraction X-ray powder diffraction techniques are used to characterize samples in the form of loose powders or aggregates of finely divided material. These techniques cover various investigations, including qualitative and quantitative phase identification and analysis, determination of crystallinity, microidentification, lattice-parameter determinations, high-temperature studies, thin film characterization, and, in some cases, crystal structure analysis. The powder method is perhaps best known for its use as a phase characterization tool partly because it can routinely differentiate between phases having the same chemical composition but different crystal structures (polymorphs). Although chemical analysis can indicate that the empirical formula for a given sample is FeTiO 3, it cannot determine whether the sample is a mixture of two phases (FeO and one of the three polymorphic forms of TiO 2 ) or whether the sample is the single-phase mineral FeTiO 3 or ilmenite. The ability of x-ray powder diffraction to perform such identifications more simply, conveniently, and routinely than any other analytical method explains its importance in many industrial applications as well as its wide availability and prevalence. 4
7 In general, an x-ray powder diffraction characterization of a substance consists of placing a powder sample of a crystalline material in a collimated monochromatic beam of x-radiation. Chapter 3 of your textbook describes the process of x-ray diffraction, and how the XRD finds the diffraction pattern for your material. The diffraction pattern is recorded on film or using detector techniques, then analyzed to provide x-ray powder data. In x-ray powder diffraction analysis, samples usually exist as finely divided powder (usually less than 44 µm in size) or can be reduced to powder form. The particles in a sample comprise one or more independently diffracting regions that coherently diffract the x-ray beam. These small crystalline regions are termed crystallites. Consolidated samples, such as ceramic bodies or asreceived metal samples, will likely have crystallites small enough to be useful for powder diffraction analysis. The size limitation is important in x-ray powder diffraction because most applications of powder diffraction rely on x-ray signals from a statistical sample of crystallites. Bragg s Law (Equation 1) states that the angular position, θ, of the diffracted x-ray beam depends on the spacing, d, between planes of atoms in a crystalline phase and on the wavelength, λ, of the x-ray. nλ = 2d sin θ [1] The intensity of the diffracted beam depends on the arrangement of the atoms on these planes. A powder pattern from a single-phase material will have maxima at positions dictated by the size and shape of its unit cell and will increase in complexity as the symmetry of the material decreases, as shown in Figure 1. For example, many metal patterns and those from simple compounds that tend to be mostly of cubic symmetry and have small unit cell edges will produce powder patterns having fewer lines or maxima than would be expected from a compound of lower symmetry or one having a very large unit cell. A pattern of a mixture of phases in which all the individual patterns are superimposed will produce a complex experimental pattern, especially when the number of phases present in the mixture exceeds approximately three or when the phases constituting the mixture are all of very low symmetry or have very large unit cell dimensions. 5
8 Figure 1. Two superimposed XRD graphs. Note that the CH 4 hydrate has distinctly more peaks than Ice (Ih), since it has a much more complex crystalline structure. Phase identification using x-ray powder diffraction is based on the unique pattern produced by every crystalline phase. Much as a fingerprint is unique for each person, the diffraction pattern can act as an empirical fingerprint for that phase, and qualitative identification of phases can be accomplished by pattern-recognition methods that include established manual techniques and the newer methods that use computers, most of which implement programs based on heuristic algorithms. All of these methods make use of the database maintained by the JCPDS International Centre for Diffraction Data. The Conventional Powder Diffractometer Although film techniques have been in use since the inception of x-ray diffraction, the advent of powder diffractometer has been more recent. Powder diffractometers have been in use as a laboratory tool since the late 1950s and early 1960s. The Bragg-Brentano geometry is used most commonly for powder diffractometers. Figure 2 shows this geometry as used for vertical diffractometers. In the vertical geometry, the axis A is horizontal. 2
9 In the variation of the Bragg-Brentano geometry that the Olin XRD system uses, termed the θ-θ diffractometer geometry, the sample is held stationary with its surface in a horizontal plane as the x-ray tube and the detector move. Figure 2. Geometry of the Bragg-Brentano diffractometer. F, line source of x-rays from the anode of the x-ray tube; P, soller slits (collimator); D, divergent slit; A, axis about which sample and detector rotate; S, sample; R, receiving slit; RP, receiving soller slits; SS, scatter slit. See the ASM Handbooks, Volume 8 Residual Stress Measurements Nondestructive Procedures for additional information on XRD instrumentation. References Callister 3.16 (on the CD) Askeland Section 3.9 ASM Handbooks Online, Volume 10 Materials Characterization, Diffraction Methods. - XRD Graph 3
10 Sample Preparation 3 Preparation of Powder Samples 1. Use fine powder if possible. If your powder is coarse (>240 grit or xxx microns), grind it with a mortar and pestle or a ball mill. 2. If only a small quantity of powder is available, skip to Step 3. If a large quantity of powder is available, fill the recess of an aluminum sample holder with powder and use a flat object, e.g., a glass slide, to level the powder with the top face of the sample holder. Skip to step If you don t have enough powder to fill the recess of an aluminum sample holder, you ll need to deposit some of your powder onto a glass slide. Mix a few drops of amyl acetate, acetone, or methanol with some of your powder to create a paste. Spread a thin, even layer of the paste onto the middle of a glass slide. It s important to maintain a fairly flat sample surface, so try to avoid bumps and chunks. When you re satisfied with the deposited layer, wait for the solvent to dry. Preparation of Solid Samples 1. Prepare a flat sample with approximate dimensions of 1 wide x 2 long x 3/16 (maximum) thick. 2. Remove all dirt, grease, etc. from the surface of the solid. 3. Load your sample. 4
11 Instrument Operation 4 This section will walk you through the basic operation of the x-ray diffractometer. You ll have to follow a series of tasks that includes Powering up the instrument, Loading your sample, Viewing system parameters and calibrating the instrument, Setting your testing conditions, Collecting x-ray diffraction data for your sample, and Analyzing your results. It may seem boring at times, but it ll be worth it! Just think of yourself as a mad scientist armed with the power to identify completely unknown samples. Is it mullite (kind of like a fossilized mullet)? Is it diamond? Is it ice-nine? Only your analysis will tell. Instrument Startup 1. Turn on the water chiller. The switch is on the right side of the front panel. 2. Turn on the XRD main power supply. The switch is on the left side of the instrument. 3. Turn on the computer and login as guest to the this computer domain (not MILKYWAY). You don t need a password. Sample Loading Load your sample, as follows: 1. Open the XRD chamber door. Inside the chamber, you will see a complex hardware system with a large sample area (in the middle) and two arms that rotate around the sample stage area. The x-ray source is mounted on the left arm, and the x-ray detector is mounted on the right arm. Unless you know what you re doing, you shouldn t touch anything connected to the rotating arms. 2. Locate the sample mounting fixture in the center of the stage assembly. The mounting fixture is a half cylinder with two spring clips (on the underside) that protrudes from the top center of the stage assembly. 3. With the sample facing up and toward you, slide your sample holder between the half-cylinder and the spring clips. If you are using an aluminum sample holder, you should center the holder (left and right edges flush with the half cylinder) and slide the holder all the way back. 4. Be careful not to get any of your powder on the XRD hardware. If you do, please wipe it off with a soft tissue or paper towel. 5
12 System Parameters Setup 1. To open the XRD hardware status software, double click the 1-Display System Parameters icon on the desktop. a. When asked to open and close the XRD chamber door, do it. This step checks the safety interlocks on the XRD chamber. b. When asked to calibrate, answer yes. This step calibrates the goniometer position. When this step is complete, you should see some numbers appear next to the Theta (deg) and 2Theta items under the Right System heading. 2. Minimize the Display or XRD System Parameter Setup Program window or move the box to the bottom right of the screen (it s sometimes nice to leave the window visible while you re testing). 6
13 Test Conditions Setup 1. Double click on the 2-Set Test Conditions icon on the desktop to open the Untitled-Right Gonio System: Analysis Condition Edit Program window. This will open a box like this: 2. To open a new test parameters window, double click on the highlighted (blue) box under Edit Analysis Condition. This will open a large dialog box with lots of adjustable test parameters. The default parameters (shown below) are fine for a typical scan (35 min.), but if you d like to speed things up a bit, try changing the Scan Speed to 4 deg. per minute. 7
14 3. When you hit OK, the following dialog box opens. Type in a filename, sample name, etc., and hit New to create a new folder for your data. 4. Hit Close to close the Standard Condition Edit dialog box. This will send you back to the Untitled-Right Gonio System: Analysis Condition Edit Program window. Don t close the window. 8
15 Testing 1. Now you need to do something weird to satisfy the quirky (or should I say lousy) software. You need to minimize all your windows and double click on the 3-Run Test icon on the desktop. This will open the Right Gonio System: Analysis and Spooler Program testing window, and for some mysterious reason, opening this window is required at this point. Minimize the new window that appears. 2. Return to your Untitled-Right Gonio System: Analysis Condition Edit Program window, which should still be open from the previous steps. 3. Click on your test method (in blue below) and hit the Append button. 4. Click the Start button. This may or may not start your test (depending on whether it s the first test to be run since the machine was turned on). You can tell that the test has started if the x-ray source clicks on and the goniometer parts start moving. 5. Click on the Right Gonio System: Analysis and Spooler Program window to see a live view of the data collection. If the test started in Step 4, you ll see some action. If the test did not start in Step 4, hit the Start button now, and the test should begin. 9
16 6. Once the test has started, sit back and enjoy the show. The entertainment value of live x-ray diffraction data collection lies somewhere between Star Wars: Episode I and Star Wars: Return of the Jedi. For those who aren t Star Wars fans, the live data collection lies somewhere between watching paint dry and watching lead oxide-laden rain water fall from our buildings. Cleanup 1. If you were testing one of the powders used in the materials science courses, return the powder to the vial. Otherwise, dispose of your powder in an appropriate manner. 2. Rinse the sample holder with DI water. You may need to use a cleaning brush to remove all the powder from the aluminum sample holders. Return the aluminum sample holders to the XRD desk. Hardware Shutdown 1. Turn off the main XRD power (left side of the instrument). 2. Wait approximately 20 minutes to allow cooling of the x-ray source, then turn off the water chiller. 10
17 Data Analysis 5 This section will walk you through basic data processing and x-ray pattern analysis. It should be noted that analysis of x-ray diffraction data is not always easy or straightforward, particularly when dealing with samples that contain multiple crystalline phases. This section presents a simplified look at data processing and analysis; there are a lot of little analytical tricks that are not presented here. You should seek help from experienced users if you have trouble analyzing a pattern. Processing Data 1. Double click on the 4-Process Data icon on the desktop to open the XRD: Basic Process window (shown below). 11
18 2. Open Windows Explorer and find your raw data file in the c:/xddata/standard xxx, where xxx are some numbers. The last Standard xxx directory should contain a folder with your sample name followed by some numbers. Open the folder with your sample name. 3. Drag and drop the *.raw data file into the background of the XRD: Basic Process window. An XRD pattern should appear, as shown below. 4. Click on the Go button on the toolbar to process your data with the standard parameters. This step will smooth your pattern, subtract background noise, separate overlapping peaks, and search for peaks. 5. You should end up with a series of XRD patterns like those shown in the following image. If everything looks ok, hit the save button on the toolbar to save the processed data. 12
19 Analyzing Data 1. Double click on the 5-Analyze-Search-Match icon on the desktop to open the Untitled: XRD Qualitative Analysis window. 2. Open your processed data file with the pkr extension. 13
20 Your pattern with marked peaks should appear in the window, as follows: 3. Go to Search Pre-Search in the pull-down menus. Click the search button to accept the default background parameters. You may want to increase the Background Intensity value if your pattern is very noisy and full of low intensity false peaks. The Background Intensity number is a percentage of the maximum peak intensity. 14
21 You should now see a number of blue peaks in the Peak Data and Residual Peak boxes, as shown below. 4. Now the fun begins. Go to Search Search in the pull-down menus to open the search Conditions dialog box. 5. Unless you know something about your sample (whether it is a mineral, organic, inorganic, metal, etc.), select the MAX search option to search all 148,000+ files in our diffraction databases. The other default parameters are usually fine, but you may want to consider changing the following: a. Matching Peaks: Value could be lowered if you only have a couple of peaks, or raised if you aren t having much success with the automatic search/match. b. B.G. Intensity: Value should match what you entered for step 3. c. Window Width: Value could be lowered if you have a relatively pure sample and a pattern with high intensity, narrow peaks. d. Exist Atom, Major Atom, and Absent Atom : These buttons open a periodic table dialog box that will allow you to select atoms that you know are present or absent in your sample. You may want to use this feature if you already have chemical data from another analysis, e.g., EDS or ICP. 15
22 6. Hit the Search button and wait for the computer to search through the tens of thousands of database entries. The result of the search is a list of possible matching materials, as shown in the example figure on the next page. The software places the matching hits in order, starting with the best match. Scroll through the matching hits, and you should see the diffraction peaks from the hit appear in the <Card Data> graph. In the example shown below, the first hit (SiO 2 ) clearly matches the collected and processed data. Take a look at the peak locations (d value) and intensities it couldn t be much better! Your sample may correspond to one of the first few hits, or it may not.. If it does not seem to match any of the suggested compounds, don t lose hope. Try entering some different search parameters and running the search again. Also, keep in mind that many real x-ray diffraction samples contain multiple crystalline phases, so look for compounds that match a few but not necessarily all of the diffraction peaks. 16
23 NOTE: If you do start to lose hope with the search/match program, call someone with a lot of x-ray diffraction experience. 7. Entering Database Cards. Once you have found a database card that seems to match your x-ray diffraction pattern, you may enter the card as a hit by clicking on the Entry button on the toolbar (the 6 th button from the left) and clicking OK. The entry action will tag your card with a specific color, and the card peaks will appear in the <Entry Data> graph. You may enter as many matching peaks as you like. Each entry will be tagged with a different color. To erase entered cards, click on the Erase button on the toolbar (the 7 th button from the left). 8. Subtracting Found Peaks. You may wish to re-run the search without the peaks from the matching database entries. To do so, click on the Search Subtract option from the pulldown menu and click on OK. This will mark matching peaks in red on the <Residual Peaks> graph and leave un-matching peaks in blue. Run the search as before (see Step 6 above), and you will receive search results for just the un-matching residual peaks. 17
Chapter 7: Basics of X-ray Diffraction
Providing Solutions To Your Diffraction Needs. Chapter 7: Basics of X-ray Diffraction Scintag has prepared this section for use by customers and authorized personnel. The information contained herein is
Introduction to X-Ray Powder Diffraction Data Analysis
Introduction to X-Ray Powder Diffraction Data Analysis Center for Materials Science and Engineering at MIT http://prism.mit.edu/xray An X-ray diffraction pattern is a plot of the intensity of X-rays scattered
X-Ray Diffraction HOW IT WORKS WHAT IT CAN AND WHAT IT CANNOT TELL US. Hanno zur Loye
X-Ray Diffraction HOW IT WORKS WHAT IT CAN AND WHAT IT CANNOT TELL US Hanno zur Loye X-rays are electromagnetic radiation of wavelength about 1 Å (10-10 m), which is about the same size as an atom. The
Rigaku XRD-System Instruction Manual v4/19/03. The Krishnan Group/Wilcox 132, University of Washington
Rigaku XRD-System Instruction Manual v4/19/03 The Krishnan Group/Wilcox 132, University of Washington Contents: - General information - Safety - How to turn on the X-rays - How to turn off the X-rays -
TA INSTRUMENTS DIFFERENTIAL SCANNING CALORIMETER (DSC) Insert Nickname Here. Operating Instructions
TA INSTRUMENTS DIFFERENTIAL SCANNING CALORIMETER (DSC) Insert Nickname Here Operating Instructions Table of Contents 1 INTRODUCTION Safety 2 Sample Preparation 3 2 BACKGROUND Background Information 4 Resources
Ch. 227 ANALYTICAL X-RAY EQUIPMENT 25
Ch. 227 ANALYTICAL X-RAY EQUIPMENT 25 CHAPTER 227. RADIATION SAFETY REQUIREMENTS FOR ANALYTICAL X-RAY EQUIPMENT, X-RAY GAUGING EQUIPMENT, ELECTRON MICROSCOPES AND X-RAY CALIBRATION SYSTEMS Sec. 227.1.
THERMO NORAN SYSTEM SIX ENERGY DISPERSIVE X- RAY SPECTROMETER. Insert Nickname Here. Operating Instructions
THERMO NORAN SYSTEM SIX ENERGY DISPERSIVE X- RAY SPECTROMETER Insert Nickname Here Operating Instructions Table of Contents 1 INTRODUCTION Safety 1 Samples 1 2 BACKGROUND Background Information 3 References
The Basics of Scanning Electron Microscopy
The Basics of Scanning Electron Microscopy The small scanning electron microscope is easy to use because almost every variable is pre-set: the acceleration voltage is always 15kV, it has only a single
Using the Spectrophotometer
Using the Spectrophotometer Introduction In this exercise, you will learn the basic principals of spectrophotometry and and serial dilution and their practical application. You will need these skills to
Atomic Force Microscope and Magnetic Force Microscope Background Information
Atomic Force Microscope and Magnetic Force Microscope Background Information Lego Building Instructions There are several places to find the building instructions for building the Lego models of atomic
Bruker AXS. D2 PHASER Diffraction Solutions XRD. think forward
Bruker AXS D2 PHASER Diffraction Solutions think forward XRD Compact all-in-one desktop design Innovative high-end goniometer design Integrated PC / monitor DIFFRAC.SUITE software Leading detector technology
A Beer s Law Experiment
A Beer s Law Experiment Introduction There are many ways to determine concentrations of a substance in solution. So far, the only experiences you may have are acid-base titrations or possibly determining
What s in the Mix? Liquid Color Spectroscopy Lab (Randy Landsberg & Bill Fisher)
What s in the Mix? Liquid Color Spectroscopy Lab (Randy Landsberg & Bill Fisher) Introduction: There is more to a color than a name. Color can tell us lots of information. In this lab you will use a spectrophotometer
X-ray thin-film measurement techniques
Technical articles X-ray thin-film measurement techniques II. Out-of-plane diffraction measurements Toru Mitsunaga* 1. Introduction A thin-film sample is two-dimensionally formed on the surface of a substrate,
. Tutorial #3 Building Complex Targets
. Tutorial #3 Building Complex Targets. Mixed Gas/Solid Targets Gas Ionization Chamber Previous Tutorials have covered how to setup TRIM, determine which ion and energy to specify for a semiconductor n-well
X-Ray Fluorescence - Data Collection and Analysis
XRF User Manual 1 X-Ray Fluorescence - Data Collection and Analysis Matthias Zeller, Jerry Hunter, Sept. 19 th 2008 A) Data Collection Logging In: The login and password to log into the program as a normal
Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9
Module 9 This module presents information on what X-rays are and how they are produced. Introduction Module 9, Page 2 X-rays are a type of electromagnetic radiation. Other types of electromagnetic radiation
PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS
PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS 1. Photons 2. Photoelectric Effect 3. Experimental Set-up to study Photoelectric Effect 4. Effect of Intensity, Frequency, Potential on P.E.
Introduction to Powder X-Ray Diffraction History Basic Principles
Introduction to Powder X-Ray Diffraction History Basic Principles Folie.1 History: Wilhelm Conrad Röntgen Wilhelm Conrad Röntgen discovered 1895 the X-rays. 1901 he was honoured by the Noble prize for
QUANTITATIVE INFRARED SPECTROSCOPY. Willard et. al. Instrumental Methods of Analysis, 7th edition, Wadsworth Publishing Co., Belmont, CA 1988, Ch 11.
QUANTITATIVE INFRARED SPECTROSCOPY Objective: The objectives of this experiment are: (1) to learn proper sample handling procedures for acquiring infrared spectra. (2) to determine the percentage composition
5. Tutorial. Starting FlashCut CNC
FlashCut CNC Section 5 Tutorial 259 5. Tutorial Starting FlashCut CNC To start FlashCut CNC, click on the Start button, select Programs, select FlashCut CNC 4, then select the FlashCut CNC 4 icon. A dialog
Physics 441/2: Transmission Electron Microscope
Physics 441/2: Transmission Electron Microscope Introduction In this experiment we will explore the use of transmission electron microscopy (TEM) to take us into the world of ultrasmall structures. This
Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid
Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid Introduction Many metals react with acids to form hydrogen gas. In this experiment, you will use the reactions
Laser Cutter User Manual
Laser Cutter User Manual frequently asked questions... the laser is cutting weird! it s cutting a thick line or not cutting through at all! Table Of Contents Section 1: Materials Guide 1.1 Can I Cut this?
MICROSCOPY. To demonstrate skill in the proper utilization of a light microscope.
MICROSCOPY I. OBJECTIVES To demonstrate skill in the proper utilization of a light microscope. To demonstrate skill in the use of ocular and stage micrometers for measurements of cell size. To recognize
X-ray Diffraction and EBSD
X-ray Diffraction and EBSD Jonathan Cowen Swagelok Center for the Surface Analysis of Materials Case School of Engineering Case Western Reserve University October 27, 2014 Outline X-ray Diffraction (XRD)
Application Note. ipix A Gamma imager to support various applications
Application Note ipix A Gamma imager to support various applications Introduction ipix is a unique gamma imager that quickly locates low level radioactive sources from a distance and estimates the dose
P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)
INSURANCE SCAM OPTICS - LABORATORY INVESTIGATION P R E A M B L E The original form of the problem is an Experimental Group Research Project, undertaken by students organised into small groups working as
1051-232 Imaging Systems Laboratory II. Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002
05-232 Imaging Systems Laboratory II Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002 Abstract: For designing the optics of an imaging system, one of the main types of tools used today is optical
Hitachi U-4100 UV-vis-NIR spectrophotometer (341-F)
Hitachi U-4100 UV-vis-NIR spectrophotometer (341-F) Please contact Dr. Amanda Young for training requests and assistance: 979-862-6845, [email protected] Hardware Our spectrophotometer is made up of
Dental Radiography collimator Ionising radiation image radiolucent area radiopaque area controlled zone scatter radiation intraoral
Dental Radiography X-rays for dental radiography are produced by high voltages of electricity within an x-ray head and come out through a metal tube called a collimator. This ensures the x-rays only come
Lectures about XRF (X-Ray Fluorescence)
1 / 38 Lectures about XRF (X-Ray Fluorescence) Advanced Physics Laboratory Laurea Magistrale in Fisica year 2013 - Camerino 2 / 38 X-ray Fluorescence XRF is an acronym for X-Ray Fluorescence. The XRF technique
Fractional Distillation and Gas Chromatography
Fractional Distillation and Gas Chromatography Background Distillation The previous lab used distillation to separate a mixture of hexane and toluene based on a difference in boiling points. Hexane boils
FREE FALL. Introduction. Reference Young and Freedman, University Physics, 12 th Edition: Chapter 2, section 2.5
Physics 161 FREE FALL Introduction This experiment is designed to study the motion of an object that is accelerated by the force of gravity. It also serves as an introduction to the data analysis capabilities
Introduction to EVA. A Complete Orientation to Features and Functions. Jonathan Giencke Application Engineer, X-ray Diffraction.
Introduction to EVA A Complete Orientation to Features and Functions Jonathan Giencke Application Engineer, X-ray Diffraction T88-E00031 Introduction to EVA 1 of 31 Overview 1. Introduction 2. Layout of
Interferometers. OBJECTIVES To examine the operation of several kinds of interferometers. d sin = n (1)
Interferometers The true worth of an experimenter consists in his pursuing not only what he seeks in his experiment, but also what he did not seek. Claude Bernard (1813-1878) OBJECTIVES To examine the
Thea Omni Light. Thea Spot Light. Light setup & Optimization
Light setup In this tutorial we will learn how to setup lights inside Thea Studio and how to create mesh lights and optimize them for faster rendering with less noise. Let us have a look at the different
CATIA Functional Tolerancing & Annotation TABLE OF CONTENTS
TABLE OF CONTENTS Introduction...1 Functional Tolerancing and Annotation...2 Pull-down Menus...3 Insert...3 Functional Tolerancing and Annotation Workbench...4 Bottom Toolbar Changes...5 3D Grid Toolbar...5
Interference. Physics 102 Workshop #3. General Instructions
Interference Physics 102 Workshop #3 Name: Lab Partner(s): Instructor: Time of Workshop: General Instructions Workshop exercises are to be carried out in groups of three. One report per group is due by
Ultraviolet-Visible (UV-Vis) Spectroscopy Background Information
1 Ultraviolet-Visible (UV-Vis) Spectroscopy Background Information Instructions for the Operation of the Cary 300 Bio UV-Visible Spectrophotometer See the Thermo OMNIC Help reference on page 49. Ultraviolet-Visible
EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.
EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions. Outcomes After completing this experiment, the student should be able to: 1. Prepare
Polarization of Light
Polarization of Light References Halliday/Resnick/Walker Fundamentals of Physics, Chapter 33, 7 th ed. Wiley 005 PASCO EX997A and EX999 guide sheets (written by Ann Hanks) weight Exercises and weights
The photoionization detector (PID) utilizes ultraviolet
Chapter 6 Photoionization Detectors The photoionization detector (PID) utilizes ultraviolet light to ionize gas molecules, and is commonly employed in the detection of volatile organic compounds (VOCs).
Applications of New, High Intensity X-Ray Optics - Normal and thin film diffraction using a parabolic, multilayer mirror
Applications of New, High Intensity X-Ray Optics - Normal and thin film diffraction using a parabolic, multilayer mirror Stephen B. Robie scintag, Inc. 10040 Bubb Road Cupertino, CA 95014 Abstract Corundum
X Ray Flourescence (XRF)
X Ray Flourescence (XRF) Aspiring Geologist XRF Technique XRF is a rapid, relatively non destructive process that produces chemical analysis of rocks, minerals, sediments, fluids, and soils It s purpose
Beckman Coulter DTX 880 Multimode Detector Bergen County Technical Schools Stem Cell Lab
Beckman Coulter DTX 880 Multimode Detector Bergen County Technical Schools Stem Cell Lab Room 213 Beckman Coulter DTX 880 Multimode Detector Information The Beckman Coulter DTX 880 Multimode Detector is
Experiment: Crystal Structure Analysis in Engineering Materials
Experiment: Crystal Structure Analysis in Engineering Materials Objective The purpose of this experiment is to introduce students to the use of X-ray diffraction techniques for investigating various types
Microsoft Windows Overview Desktop Parts
Microsoft Windows Overview Desktop Parts Icon Shortcut Icon Window Title Bar Menu Bar Program name Scroll Bar File Wallpaper Folder Start Button Quick Launch Task Bar or Start Bar Time/Date function 1
PARALLEL BEAM METHODS IN POWDER DIFFRACTION AND TEXTURE IN THE LABORATORY.
Copyright(c)JCPDS-International Centre for Diffraction Data 2000,Advances in X-ray Analysis,Vol.43 135 PARALLEL BEAM METHODS IN POWDER DIFFRACTION AND TEXTURE IN THE LABORATORY. R.A. Clapp and M.Halleti
THE BOHR QUANTUM MODEL
THE BOHR QUANTUM MODEL INTRODUCTION When light from a low-pressure gas is subject to an electric discharge, a discrete line spectrum is emitted. When light from such a low-pressure gas is examined with
Microsoft Excel 2010 Charts and Graphs
Microsoft Excel 2010 Charts and Graphs Email: [email protected] Web Page: http://training.health.ufl.edu Microsoft Excel 2010: Charts and Graphs 2.0 hours Topics include data groupings; creating
SolidWorks Building Blocks Tutorial. Toy-car
SolidWorks Building Blocks Tutorial Toy-car From the age of until the age of For use with SolidWorks Educational Release 2010-2011 This tutorial was developed for SolidWorks Worldwide and may be used by
CONFOCAL LASER SCANNING MICROSCOPY TUTORIAL
CONFOCAL LASER SCANNING MICROSCOPY TUTORIAL Robert Bagnell 2006 This tutorial covers the following CLSM topics: 1) What is the optical principal behind CLSM? 2) What is the spatial resolution in X, Y,
Coating Thickness and Composition Analysis by Micro-EDXRF
Application Note: XRF Coating Thickness and Composition Analysis by Micro-EDXRF www.edax.com Coating Thickness and Composition Analysis by Micro-EDXRF Introduction: The use of coatings in the modern manufacturing
6) How wide must a narrow slit be if the first diffraction minimum occurs at ±12 with laser light of 633 nm?
Test IV Name 1) In a single slit diffraction experiment, the width of the slit is 3.1 10-5 m and the distance from the slit to the screen is 2.2 m. If the beam of light of wavelength 600 nm passes through
Windows XP Pro: Basics 1
NORTHWEST MISSOURI STATE UNIVERSITY ONLINE USER S GUIDE 2004 Windows XP Pro: Basics 1 Getting on the Northwest Network Getting on the Northwest network is easy with a university-provided PC, which has
Crystal Structure Determination I
Crystal Structure Determination I Dr. Falak Sher Pakistan Institute of Engineering and Applied Sciences National Workshop on Crystal Structure Determination using Powder XRD, organized by the Khwarzimic
Intermediate PowerPoint
Intermediate PowerPoint Charts and Templates By: Jim Waddell Last modified: January 2002 Topics to be covered: Creating Charts 2 Creating the chart. 2 Line Charts and Scatter Plots 4 Making a Line Chart.
Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014
Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014 Introduction Following our previous lab exercises, you now have the skills and understanding to control
How to operate the BD FACSCanto flow cytometer
How to operate the BD FACSCanto flow cytometer Preface Dear colleague, the BD FACSCanto flow cytometer is use to operate, however, it is a delicate instrument for measuring fluorescence of single cells.
Hygro-Thermometer + InfraRed Thermometer Model RH101
User's Guide Hygro-Thermometer + InfraRed Thermometer Model RH101 Introduction Congratulations on your purchase of the Extech Hygro-Thermometer plus InfraRed Thermometer. This device measures relative
Ultrasonic Wave Propagation Review
Ultrasonic Wave Propagation Review Presented by: Sami El-Ali 1 1. Introduction Ultrasonic refers to any study or application of sound waves that are higher frequency than the human audible range. Ultrasonic
SMART Board Tips & Tricks (version 9.0) Getting Started. SMART Tools vs. SMART Notebook software
SMART Board Tips & Tricks (version 9.0) Getting Started SMART Tools vs. SMART Notebook software Click the SMART Board icon (in the system tray at the bottom right of your screen) to access the SMART Board
Create a Poster Using Publisher
Contents 1. Introduction 1. Starting Publisher 2. Create a Poster Template 5. Aligning your images and text 7. Apply a background 12. Add text to your poster 14. Add pictures to your poster 17. Add graphs
Easy Machining Center Setup
White Paper Document No. MWA-072-EN_01_1404 April 2014 Easy Machining Center Setup Using FANUC s Direct Input of Workpiece Origin Setting Measured and Tool Length Measurement features to easily establish
Blackbody Radiation References INTRODUCTION
Blackbody Radiation References 1) R.A. Serway, R.J. Beichner: Physics for Scientists and Engineers with Modern Physics, 5 th Edition, Vol. 2, Ch.40, Saunders College Publishing (A Division of Harcourt
Experiment 5: Magnetic Fields of a Bar Magnet and of the Earth
MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Physics 8.02 Spring 2005 Experiment 5: Magnetic Fields of a Bar Magnet and of the Earth OBJECTIVES 1. To examine the magnetic field associated with a
Lapping and Polishing Basics
Lapping and Polishing Basics Applications Laboratory Report 54 Lapping and Polishing 1.0: Introduction Lapping and polishing is a process by which material is precisely removed from a workpiece (or specimen)
Physical Properties of a Pure Substance, Water
Physical Properties of a Pure Substance, Water The chemical and physical properties of a substance characterize it as a unique substance, and the determination of these properties can often allow one to
Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry
Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry Jon H. Hardesty, PhD and Bassam Attili, PhD Collin College Department of Chemistry Introduction: In the last lab
Austin Peay State University Department of Chemistry Chem 1111. The Use of the Spectrophotometer and Beer's Law
Purpose To become familiar with using a spectrophotometer and gain an understanding of Beer s law and it s relationship to solution concentration. Introduction Scientists use many methods to determine
RapidScan3D Ultrasonic Instrumentation Quick Start Guide
RapidScan3D Ultrasonic Instrumentation Quick Start Guide Part Number: 147363 Setting up the RapidScan3D System Terminology used in this document includes: instrument the black Peli-case and its contents;
Chemistry 111 Lab: Intro to Spectrophotometry Page E-1
Chemistry 111 Lab: Intro to Spectrophotometry Page E-1 SPECTROPHOTOMETRY Absorption Measurements & their Application to Quantitative Analysis study of the interaction of light (or other electromagnetic
Introduction to Geiger Counters
Introduction to Geiger Counters A Geiger counter (Geiger-Muller tube) is a device used for the detection and measurement of all types of radiation: alpha, beta and gamma radiation. Basically it consists
X-ray Production. Target Interactions. Principles of Imaging Science I (RAD119) X-ray Production & Emission
Principles of Imaging Science I (RAD119) X-ray Production & Emission X-ray Production X-rays are produced inside the x-ray tube when high energy projectile electrons from the filament interact with the
Becton-Dickinson FACSCalibur Flow Cytometer Instructions
Start-up 1. Turn on flow cytometer by pushing green button on right side of instrument, toward the back. Give it 30 minutes to warm up before collecting data. 2. Turn on monitor. 3. Turn on computer. If
Introduction. POP and IMAP Servers. MAC1028 June 2007
MAC1028 June 2007 Getting Started with Thunderbird 2.0 For Macintosh OS X Author: John A. Montgomery Adapted to OS X by: Peter Lee Revised by Mitchell Ochi and Deanna Pasternak Introduction...1 POP and
New Portable X-Ray Diffraction/X-Ray Fluorescence Instrument (XRD/XRF)
1 New Portable X-Ray Diffraction/X-Ray Fluorescence Instrument (XRD/XRF) Introduction The primary goal of most analyses of art objects is to identify the material composition of the object. This may lead
Lesson 26: Reflection & Mirror Diagrams
Lesson 26: Reflection & Mirror Diagrams The Law of Reflection There is nothing really mysterious about reflection, but some people try to make it more difficult than it really is. All EMR will reflect
Paper Chromatography: Separation and Identification of Five Metal Cations
Paper Chromatography: Separation and Identification of Five Metal Cations Objectives Known and unknown solutions of the metal ions Ag +, Fe 3+, Co 2+, Cu 2+ and Hg 2+ will be analyzed using paper chromatography.
Using Microsoft Word. Working With Objects
Using Microsoft Word Many Word documents will require elements that were created in programs other than Word, such as the picture to the right. Nontext elements in a document are referred to as Objects
AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light
AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light Name: Period: Date: MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question. 1) Reflection,
Cura for Type A Machines Quick Start Guide
Cura for Type A Machines Quick Start Guide 1 Table of Contents About Cura for Type A Machines Downloading Cura for Type A Machines Installing Cura for Type A Machines Mac Windows Linux About the Configuration
Plots, Curve-Fitting, and Data Modeling in Microsoft Excel
Plots, Curve-Fitting, and Data Modeling in Microsoft Excel This handout offers some tips on making nice plots of data collected in your lab experiments, as well as instruction on how to use the built-in
1. Three-Color Light. Introduction to Three-Color Light. Chapter 1. Adding Color Pigments. Difference Between Pigments and Light. Adding Color Light
1. Three-Color Light Chapter 1 Introduction to Three-Color Light Many of us were taught at a young age that the primary colors are red, yellow, and blue. Our early experiences with color mixing were blending
The Analytical Balance
Chemistry 119: Experiment 1 The Analytical Balance Operation of the Single-Pan Analytical Balance Receive instruction from your teaching assistant concerning the proper operation of the Sartorius BP 210S
Fraunhofer Diffraction
Physics 334 Spring 1 Purpose Fraunhofer Diffraction The experiment will test the theory of Fraunhofer diffraction at a single slit by comparing a careful measurement of the angular dependence of intensity
Scientific Graphing in Excel 2010
Scientific Graphing in Excel 2010 When you start Excel, you will see the screen below. Various parts of the display are labelled in red, with arrows, to define the terms used in the remainder of this overview.
Survival Laser SL-001BB Laser Parts Bundle Assembly & Operation Instructions
Survival Laser SL-001BB Laser Parts Bundle Assembly & Operation Instructions WARNING: READ ALL INSTRUCTIONS AND THE ENCLOSED SAFETY PRECAUTIONS BEFORE ASSEMBLY AND USE Assemble and use these parts ONLY
Holes & Selective Laser Sintering
SLS is one of the most accurate 3D printing processes. The process has a layer thickness of 0.1mm. This is the thickness with which a new layer is added to each part. In any direction therefore the maximum
Excel -- Creating Charts
Excel -- Creating Charts The saying goes, A picture is worth a thousand words, and so true. Professional looking charts give visual enhancement to your statistics, fiscal reports or presentation. Excel
Introduction to microstructure
Introduction to microstructure 1.1 What is microstructure? When describing the structure of a material, we make a clear distinction between its crystal structure and its microstructure. The term crystal
PARTICLE SIZES EXPLAINED
PARTICLE SIZES EXPLAINED You will often see chemicals in fireworks and propellant formulas that look like these: Aluminum, atomized, 22 micron Aluminum, -325 mesh Aluminum, -325 mesh, spherical, 22 micron
Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity
Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Innovation with Integrity Micro-CT 3D Microscopy Using Micro-CT for SEM Micro-CT for SEM
The Determination of an Equilibrium Constant
The Determination of an Equilibrium Constant Computer 10 Chemical reactions occur to reach a state of equilibrium. The equilibrium state can be characterized by quantitatively defining its equilibrium
8001782 Owner s Manual
8001782 Digital Infrared Thermometer Owner s Manual Introduction This instrument is a portable, easy to use compact-size digital thermometer with laser sighting designed for one hand operation. The meter
Polarization Dependence in X-ray Spectroscopy and Scattering. S P Collins et al Diamond Light Source UK
Polarization Dependence in X-ray Spectroscopy and Scattering S P Collins et al Diamond Light Source UK Overview of talk 1. Experimental techniques at Diamond: why we care about x-ray polarization 2. How
Experiment 5. Lasers and laser mode structure
Northeastern University, PHYS5318 Spring 2014, 1 1. Introduction Experiment 5. Lasers and laser mode structure The laser is a very important optical tool that has found widespread use in science and industry,
PART H RADIATION SAFETY REQUIREMENTS FOR ANALYTICAL X-RAY EQUIPMENT. Definitions. As used in this Part, the following definitions apply:
PART H RADIATION SAFETY REQUIREMENTS FOR ANALYTICAL X-RAY EQUIPMENT Sec. H.1 Purpose and Scope. This Part provides special requirements for analytical x-ray equipment. The requirements of this Part are