In the previous presentation, we discussed how x-rays were discovered and how they are generated at the atomic level. Today we will begin the
|
|
|
- Norman Campbell
- 9 years ago
- Views:
Transcription
1 In the previous presentation, we discussed how x-rays were discovered and how they are generated at the atomic level. Today we will begin the discussion on the major components of the x-ray machine. Today s discussion will focus on the x-ray tube. In the picture, you can see the technologist handling the x-ray tube. She is manipulating the field size by adjusting a device called the collimator which is attached to the x- ray tube housing. The rectangular looking device just above the collimator is the housing for the x-ray tube. The diagram on the right shows the x-ray tube by itself. There are three major components that we will be discussing: The cathode which is negatively charged. Note its position on the diagram above. The Anode which is positively charged. And the Glass Envelope which supports the anode and cathode structures. 1
2 As indicated in the previous slide, the cathode structure is electrically negative. This is negative because it is a source of electrons. Note that the diagram shows a magnified view of the cathode face and it shows dual filaments. Only one filament at a time will work. The small filament is designed to be used with relatively small parts while the large filament is used when larger body parts are being x-rayed. The structure which supports the filaments is known as the focusing cup. It is designed and shaped so that when the x-ray machine is powered up, electrons will literally boil off the filament. It glows white hot and the electrons hover around the filament in a space charge until the moment of exposure and then they accelerate very rapidly towards the anode which is not very far away. This process is known as thermionic emission. Thermionic emission occurs when the technologist begins to make an exposure by pressing the ready button on the machine. This action initiates the boost phase or that part of the exposure process where the x-ray tube is being prepared for the exposure to take place. While you cannot see the actual shape of the focusing cup, it is designed such that it helps concentrate the electron stream in a pre-determined area on the Anode target area known as a focal spot. The filament has its own circuit powered by a relatively low voltage and 4 6 amperes. 2
3 In this slide, we have two examples of how electrons can function given two different conditions. In the model on top, you will see that because electrons repulse each other, as soon as they leave the structure, the electrons tend to spread out. This would not be conducive to good x-ray production. The spread of the electrons occurred because the focusing cup is not negatively charged. In the second model, you will notice that the cathode structure is negatively charged. This charge then forces the electrons together as they exit the cathode structure thereby ensuring that the electrons stream does strike the focal spot in a relatively small area. 3
4 This slide shows how a non-functioning focusing cup would result in a wide spray pattern of electrons. This would result in xrays being generated in a wide area rather than in a small focal spot which is essential for clear images. 4
5 With this slide, you can clearly see that the distance between the cathode and the rotating anode disc is very close. This is designed this way to ensure that the projectile electron stream has a reasonably good chance of arriving at the anode in a relatively tight pattern. If the electrons were premitted to spread out, then the x-ray production process would become very inefficient. 5
6 These diagrams demonstrate two operating conditions which influence the x-ray production process. Please note that the number of electrons that are released will directly influence the number of x-rays that are generated and therefore the dose of radiation also. While these diagrams show just a few electrons, the reality is that there are countless billions of electrons that are typically released during any exposure. This diagram shows how a low ma will result in fewer x-rays being produced and a high ma will result in a greater number of x-rays. The term ma is a unit of measure of electrical current that is used when the technologist selects the exposure factors. ma is one of four Prime Exposure Factors we will be discussing soon. 6
7 In summary,the cathode structure, contains the filament and the focusing cup. The purpose for the filament cut is to guide the electron stream to the target area on the anode. Because of the tremendous amount of heat that is generated at the cathode, the structure is made of molybdenum nickel alloy which has excellent thermal qualities. 7
8 The technologist has the responsibility of choosing which filament to use with any given procedure. The technologist automatically selects the filament of choice when the focal spot size is chosen. As previously mentioned, the focal spot size that is selected is based on the relative size of the part that is to be x-rayed. In general, large body parts will require the selection of the large focal spot setting and small parts, require the small focal spot. 8
9 The 2 nd major part of the x-ray tube is the Anode. The anode has a positive electrical charge and attracts electrons when the exposure button is pressed. The anode is actually a disc made of Tungsten because of its thermal qualities also. The disc is designed to rotate during operation. Recall how the cathode is positioned in relation to the anode and you can see that the electron stream will strike at the lower part of the disc along an area called the focal track. It is called a track because the anode rotates very fast and the idea is for the electrons to not concentrate on any given spot for any length of time. Rotation spreads the build-up of heat along the entire disc rather than just one given spot. The specific spot along the track where the electron stream strikes is called the focal spot or tube focus. The focal spot settings available are large and small. Example sizes are 2.0 millimeters square for the large size and 1.0 millimeter square for the small size. As you recall from the arrangment of the filaments, the small filament directs its electron stream to the small focus while using the large filament, directs the stream over the larger focal spot. The small focal spot is superimposed over the large one. 9
10 This diagram demonstrates the relative position of the anode and cathode and the resulting emission of x-rays. Note that the anode is attached to a cylindrical part known as the rotor. The rotor is actually part of a motor that is made to rotate at very high speed. In most x-ray tubes, the revolutions per minute is usually at 3,200 for standard technique settings, however if the technologist selects exposure factors that are considerably larger and therefore very hot, then the rotor can rotate at a much greater speed exceeding 5,000 rpm. The rotation of the anode ensures that not any one spot will receive successive pulses of electrons. If there was no rotation, then it is very likely that the anode face would be damaged due to high heat. 10
11 This photo shows the face of an anode. In this model, it shows considerable wear along the focal track. Typically, when an xray tube is new, the anode face is very shiny and smooth, however as time goes on, the wear begins as a result of the tremendous heat produced when the electrons strike the anode. The face becomes worn and rough and may eventually fail or crack. To increase the durability of the disc, it is comprised of molybdenum with the focal track imbedded in the disc. The focal spot track is made of rhenium and tungsten. The back of the anode disc is lined with graphite for improved heat loading. 11
12 As we discussed in the initial slides where we spoke of how x-rays are produced, it is important to note that the metal used for producing x-rays must not only have good thermal qualities, it must also be able to produce x-rays easily. To ensure that the projectile electrons have an excellent probability of x-ray production, the atoms must have a high atomic density or a good concentration of electrons. Tungsten is an excellent metal for this. It has a high atomic number of seventy-four. This increases the probability of brems and characteristic radiation. It has a very high melting point and it can dissipate its heat by radiating it out through the glass 12
13 The focal spots which are imbedded in the rotating anode disc are angled in such a way that when the electrons strike the anode focal track, the angle makes it easier for the x-rays to be emitted in a downward direction. Notice in this picture how the anode face has an angle. While the projectile electrons do not bounce away from the target, the angle at which it is positioned allows more x-rays to be directed toward the image receptor or film. 13
14 The actual dimensions of a typical focal spot may be 1 mm X 2 mm along the focal track, however depending on the angle of the anode face, this will change the appearance of the focal spot as seen from below or where the x-ray image receptor is positioned. The anode angle and the resulting appearance of the focal spot as it would appear from the image receptor is known as the Line Focus Principle. In the diagram model here please note that as the angle of the anode decreases from 17 degrees to 7 degrees, the focal spot will appear smaller because you are looking up at it at an angle or obliquely. As the angle decreases, you actually see less of the focal spot dimensions and this will actually enhance the recorded details on the image. In general, the smaller the focal spot is, either real or as changed by the line focus principle, the better the detail will be on the finished image. 14
15 The next component of the x-ray tube is the glass envelope. The type of glass that is used in the construction of x-ray tubes is pyrex. This is the same type of glass that is used in cookware which can tolerate tremendous heat levels. It is important to understand that when x-rays are generated, tungsten is vaporized from the target surface as well as from the filament when it is heated. As time goes on, the diameter of the filament decreases because the tungsten is being vaporized. Because the glass envelope is sealed, the vaporized tungsten will tend to settle on the inside glass surface. Specifically, the tungsten settles over the exit port of the radiation. The area of the glass envelope that is immediately under the anode is somewhat thinner to minimize the attenuation or absorption of the x-rays as they pass through this part of the tube. However, as the tube ages, more and more tungsten will coat the inside of the tube and this makes it more difficult for the x-rays to come out of the tube. To expedite cooling and to insulate the tube, it is immersed in oil to ensure that it is electrically insulated and so that the oil will also help cool down the tube during operation. The cooling of the oil is sometimes assisted with a cooling fan. 15
16 This diagram demonstrates the x-ray tube with all its components labeled clearly. Note that the anode is attached to the rotor by a small diameter stem. The Rotor is made of copper which is actually part of a motor that is made to rotate by the device called the stator. The stator is a set of electric coils that produces a very strong magnetic field outside of the glass envelope that in turn pulls along the copper rotor. The stator causes the rotor to rotate very fast just like any electric motor. The stator is also called an induction motor. The rotor typically spins at around 3,200 revolutions per minute, however when a large exposure setting is used, then the rotor can spin at close to ten thousand revolutions per minute. Another component that is not seen in this diagram are the bearings which permit a very smooth rotation of the anode. The bearings are very sensitive and if the x-ray tube heats up abnormally high, they can be damaged and can cause the rotor to rotate at less than 3,200 rpm. If this occurs, the target surface can be damaged or pitted. 16
17 This daigram shows the entire x-ray tube contained in the protective housing. The housing is usually comprised of metal such as stainless steel and it serves as a very strong support for the rather delicate x-ray tube. The red lines you see are the electrical cables that power the x-ray tube. The xray tube is placed in the housing and then the housing is filled with oil. The oil serves two major purposes: One, it helps cool the x-ray tube just like oil in your car helps cool the engine. Additionally, the oil helps insulate electrically for safety and one additional thing it does is if you notice where the primary beam exits the housing, the x-rays must pass through a small thinkness of oil before they emerge from the tube and this contributes to minimal filtration or absorption of the x-ray beam when you make an exposure. 17
18 Another important function that the protective housing performs is to help control any leakage radiation. As you may recall from a previous discussion, x-rays are produced isotropically or in all directions such as what you see in this diagram. The x- rays that we want to use are permitted out at the bottom of the tube as shown here, however the rest of the radiation that is traveling in other directions is absorbed by the housing itself as well as the cooling oil. 18
19 The last slide in this discussion demonstrates a stationary anode x-ray tube. Note that this only shows the anode part of the tube. It is called stationary because the anode does not rotate but rather remains stationary during an exposure. This is a great limiting factor that reduces its efficiency and its use. Note that the focal spot is a tungsten button that is imbedded in a copper stem. The purpose of the stem is to conduct the heat out of the xray tube. This is different compared to the rotating anode which radiates away the heat through the glass. The stationary anode tube will conduct the heat out of the tube to the surrounding oil. This type of tube does not have as much power as the rotating anode x-ray tube. A lab model of this type of tube will be demonstrated in lab. 19
X-ray Imaging Systems
Principles of Imaging Science I (RAD 119) X-ray Tube & Equipment X-ray Imaging Systems Medical X-ray Equipment Classified by purpose or energy/current levels kvp, ma Radiographic Non-dynamic procedures
X-ray Imaging Systems
Principles of Imaging Science I (RAD 119) X-ray Tube & Equipment X-ray Imaging Systems Medical X-ray Equipment Classified by purpose or energy/current levels kvp, ma Radiographic Non-dynamic procedures
Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9
Module 9 This module presents information on what X-rays are and how they are produced. Introduction Module 9, Page 2 X-rays are a type of electromagnetic radiation. Other types of electromagnetic radiation
X-ray Production. Target Interactions. Principles of Imaging Science I (RAD119) X-ray Production & Emission
Principles of Imaging Science I (RAD119) X-ray Production & Emission X-ray Production X-rays are produced inside the x-ray tube when high energy projectile electrons from the filament interact with the
Cathode Ray Tube. Introduction. Functional principle
Introduction The Cathode Ray Tube or Braun s Tube was invented by the German physicist Karl Ferdinand Braun in 897 and is today used in computer monitors, TV sets and oscilloscope tubes. The path of the
Voltage nominal maximum for test. Inverse voltage. nominal maximum for test. Focal spots (IEC 60336:2005) small large
TECHNICAL DATA GENERAL INFORMATIONS Voltage nominal maximum for test 1 135 kv When mounting tube inserts adopt proper caution, in order to avoid glass bulb breaking and fragments projection. Please use
PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator.
PHYS 222 Spring 2012 Final Exam Closed books, notes, etc. No electronic device except a calculator. NAME: (all questions with equal weight) 1. If the distance between two point charges is tripled, the
X-Mind. Instinct for perfection
X-Mind Instinct for perfection X-Mind tubes are located at the back of the head which gives the patient better protection because the distance between the focal spot and the skin is 50% greater than in
The Tesla Roadster battery pack is comprised of about 6800 of these 18650 cells, and the entire pack has a mass of about 450kg.
The Tesla Roadster Battery System Tesla Motors August 16, 2006 By Gene Berdichevsky, Kurt Kelty, JB Straubel and Erik Toomre Summary This paper provides details about the design of the Tesla Roadster s
E/M Experiment: Electrons in a Magnetic Field.
E/M Experiment: Electrons in a Magnetic Field. PRE-LAB You will be doing this experiment before we cover the relevant material in class. But there are only two fundamental concepts that you need to understand.
Evaluating Induction Motor Rotor Bars with Electrical Signature Analysis
Evaluating Induction Motor Rotor Bars with Electrical Signature Analysis Howard W Penrose, Ph.D., CMRP SUCCESS by DESIGN Reliability Services Hello and welcome to our presentation on Evaluating Induction
AS COMPETITION PAPER 2008
AS COMPETITION PAPER 28 Name School Town & County Total Mark/5 Time Allowed: One hour Attempt as many questions as you can. Write your answers on this question paper. Marks allocated for each question
Torque motors. direct drive technology
Torque motors direct drive technology Why Direct Drive Motors? Fast and effective Direct-drive technology in mechanical engineering is defined as the use of actuators which transfer their power directly
Standex-Meder Electronics. Custom Engineered Solutions for Tomorrow
Standex-Meder Electronics Custom Engineered Solutions for Tomorrow Reed Switch Technology Product Training Copyright 2013 Standex-Meder Electronics. All rights reserved. Introduction Purpose Discover Standex-Meder
The Electrical Properties of Materials: Resistivity
The Electrical Properties of Materials: Resistivity 1 Objectives 1. To understand the properties of resistance and resistivity in conductors, 2. To measure the resistivity and temperature coefficient of
X-RAY TUBE SELECTION CRITERIA FOR BGA / CSP X-RAY INSPECTION
X-RAY TUBE SELECTION CRITERIA FOR BGA / CSP X-RAY INSPECTION David Bernard Dage Precision Industries Inc. Fremont, California [email protected] ABSTRACT The x-ray inspection of PCB assembly processes
Chen. Vibration Motor. Application note
Vibration Motor Application note Yangyi Chen April 4 th, 2013 1 Table of Contents Pages Executive Summary ---------------------------------------------------------------------------------------- 1 1. Table
Energy and Energy Transformations Test Review
Energy and Energy Transformations Test Review Completion: 1. Mass 13. Kinetic 2. Four 14. thermal 3. Kinetic 15. Thermal energy (heat) 4. Electromagnetic/Radiant 16. Thermal energy (heat) 5. Thermal 17.
The Basics of Scanning Electron Microscopy
The Basics of Scanning Electron Microscopy The small scanning electron microscope is easy to use because almost every variable is pre-set: the acceleration voltage is always 15kV, it has only a single
General Guidelines for Building Aluminum Production Injection Molds
General Guidelines for Building Aluminum Production Injection Molds Using 7000 series Aluminum Mold Plate By David Bank Aluminum Injection Mold Company Rochester, New York 1 Introduction This high strength
Thermopile Support: FAQs, Troubleshooting, Care & Maintenance
Thermopile Support: FQs, Troubleshooting, Care & Maintenance Table of Contents 1. Introduction 2. How long does a thermopile sensor last and how accurate does it remain over time? 3. What are typical causes
Vacuum Evaporation Recap
Sputtering Vacuum Evaporation Recap Use high temperatures at high vacuum to evaporate (eject) atoms or molecules off a material surface. Use ballistic flow to transport them to a substrate and deposit.
Shaft grounding. Carbon brushes for shaft grounding are used in turbo-generators, in distinct AC- and DC motors and as a special application in Ships.
"Modern AC-Motors don't need carbon brushes and are maintenance free " Until some years ago this thrilling statement could be heard from motor OEM's. Nowadays SCHUNK supplies carbon brushes and brush holders
The Three Heat Transfer Modes in Reflow Soldering
Section 5: Reflow Oven Heat Transfer The Three Heat Transfer Modes in Reflow Soldering There are three different heating modes involved with most SMT reflow processes: conduction, convection, and infrared
i3 STC Kit Extension Activities North Carolina
i3 STC Kit Extension Activities North Carolina Grade: 4th Kit Name: Electrical Circuits Essential Standard(s): (List number, standard, clarifying objectives where appropriate) 4.P.1 Explain how various
Topic Page Contents Page
Heat energy (11-16) Contents Topic Page Contents Page Heat energy and temperature 3 Latent heat energy 15 Interesting temperatures 4 Conduction of heat energy 16 A cooling curve 5 Convection 17 Expansion
Production of X-rays and Interactions of X-rays with Matter
Production of X-rays and Interactions of X-rays with Matter Goaz and Pharoah. Pages 11-20. Neill Serman Electrons traveling from the filament ( cathode) to the target (anode) convert a small percentage
Interested in conducting your own webinar? Email [email protected]
Interested in conducting your own webinar? Email [email protected] IR Applications in the Real World Archive www.process-heating.com Add to your favorites IR Applications in the Real World What it
1. At which temperature would a source radiate the least amount of electromagnetic energy? 1) 273 K 3) 32 K 2) 212 K 4) 5 K
1. At which temperature would a source radiate the least amount of electromagnetic energy? 1) 273 K 3) 32 K 2) 212 K 4) 5 K 2. How does the amount of heat energy reflected by a smooth, dark-colored concrete
Material Comparison Lower Quality Blender Optimum 9400. Electric Motor Assembly. Plastic Fans Low cost
Below is a factual comparison between our Optimum 9400 model and a lower quality high-speed blender dated May 20 th 2014. This comparison has been independently conducted, reviewing the key components
2005 WJTA American Waterjet Conference August 21-23, 2005 Houston, Texas Paper SAFE WATERJET CLEANING OF STEEL PROCESS LINES
25 WJTA American Waterjet Conference August 21-23, 25 Houston, Texas Paper SAFE WATERJET CLEANING OF STEEL PROCESS LINES D. Wright, J. Wolgamott, G. Zink StoneAge, Inc. Durango, Colorado, U.S.A. ABSTRACT
5.2 ASSESSMENT OF X-RAY TUBE LEAKAGE RADIATION AND X-RAY TUBE OUTPUT TOTAL FILTRATION
5.2 ASSESSMENT OF X-RAY TUBE LEAKAGE RADIATION AND X-RAY TUBE OUTPUT TOTAL FILTRATION 5.2.1 Task The bremsstrahlung produced by the X-ray tube has a continuous spectrum, limited by the set and spreads
A/C refrigerant system, overview
Page 1 of 19 87-18 A/C refrigerant system, overview A/C refrigerant system, identification Typical A/C refrigerant system with expansion valve and receiver drier 1 - Evaporator 2 - Expansion valve 3 -
1. The diagram below represents magnetic lines of force within a region of space.
1. The diagram below represents magnetic lines of force within a region of space. 4. In which diagram below is the magnetic flux density at point P greatest? (1) (3) (2) (4) The magnetic field is strongest
Understanding the Alternator
http://www.autoshop101.com THIS AUTOMOTIVE SERIES ON ALTERNATORS HAS BEEN DEVELOPED BY KEVIN R. SULLIVAN PROFESSOR OF AUTOMOTIVE TECHNOLOGY AT SKYLINE COLLEGE SAN BRUNO, CALIFORNIA ALL RIGHTS RESERVED
Electric Motor. Your Activity Build a simple electric motor. Material. Create. Science Topics. What s going on? 2 Jumbo Safety Pins (or Paper Clips)
Electric Motor Your Activity Build a simple electric motor Material D-Cell Battery Coil made out of magnet wire 2 Jumbo Safety Pins (or Paper Clips) Scissors (or sand paper) 1 Rubber Band Ceramic Magnet
جامعة البلقاء التطبيقية
AlBalqa Applied University تا سست عام 997 The curriculum of associate degree in Air Conditioning, Refrigeration and Heating Systems consists of (7 credit hours) as follows: Serial No. Requirements First
Lecture slides on rolling By: Dr H N Dhakal Lecturer in Mechanical and Marine Engineering, School of Engineering, University of Plymouth
Lecture slides on rolling By: Dr H N Dhakal Lecturer in Mechanical and Marine Engineering, School of Engineering, University of Plymouth Bulk deformation forming (rolling) Rolling is the process of reducing
TEACHER BACKGROUND INFORMATION THERMAL ENERGY
TEACHER BACKGROUND INFORMATION THERMAL ENERGY In general, when an object performs work on another object, it does not transfer all of its energy to that object. Some of the energy is lost as heat due to
Roller Chain Coupling
Roller Chain Coupling Features 1. Simple structure A roller chain coupling consists of one duplex roller chain and two sprockets for a simplex chain. Handling is very simple as both the shafts (driving
! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)
Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications McDonnell & Miller Installation & Maintenance Instructions
SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS
SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive
Lead & Magnet Wire Connection Methods Using the Tin Fusing Method Joyal A Division of AWE, Inc.
Lead & Magnet Wire Connection Methods Using the Tin Fusing Method Joyal A Division of AWE, Inc. Abstract The technology for connecting lead and magnet wires for electric motors and electro mechanical devices
DIRECT CURRENT GENERATORS
DIRECT CURRENT GENERATORS Revision 12:50 14 Nov 05 INTRODUCTION A generator is a machine that converts mechanical energy into electrical energy by using the principle of magnetic induction. This principle
THE EFFECT OF BLADE ANGLE AND SIZE ON WIND TURBINE PERFORMANCE
THE EFFECT OF BLADE ANGLE AND SIZE ON WIND TURBINE PERFORMANCE Anish Bhattacharya, 8 th Grade, Unity Point School District 140 PURPOSE We have experienced a major fall in the economy in the recent past.
NetShape - MIM. Metal Injection Molding Design Guide. NetShape Technologies - MIM Phone: 440-248-5456 31005 Solon Road FAX: 440-248-5807
Metal Injection Molding Design Guide NetShape Technologies - MIM Phone: 440-248-5456 31005 Solon Road FAX: 440-248-5807 Solon, OH 44139 [email protected] 1 Frequently Asked Questions Page What
Electron Beam and Sputter Deposition Choosing Process Parameters
Electron Beam and Sputter Deposition Choosing Process Parameters General Introduction The choice of process parameters for any process is determined not only by the physics and/or chemistry of the process,
LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes
LBS-300 Beam Sampler for C-mount Cameras P/N SP90183, SP90184, SP90185 and SP90186 YAG Focal Spot Analysis Adapter P/N SP90187, SP90188, SP90189, SP90190, SP90191 User Notes Ophir-Spiricon Inc. 60 West
Sap Steady UV Unit for Maple Sap
Cornell Maple Bulletin 203 (2007) Sap Steady UV Unit for Maple Sap by BRIAN CHABOT Overview Components The Sap-Steady unit from FPE Inc. (Macedon NY) has been designed to kill bacteria yeast, and some
Application Information
Moog Components Group manufactures a comprehensive line of brush-type and brushless motors, as well as brushless controllers. The purpose of this document is to provide a guide for the selection and application
BUT PRECAUTIONS MUST BE TAKEN OR SERIOUS BURNS CAN RESULT.
Cooling System Operation Below is an explanation of this system's operation Radiator The radiator is a device designed to dissipate the heat which the coolant has absorbed from the engine. It is constructed
DC GENERATOR THEORY. LIST the three conditions necessary to induce a voltage into a conductor.
DC Generators DC generators are widely used to produce a DC voltage. The amount of voltage produced depends on a variety of factors. EO 1.5 LIST the three conditions necessary to induce a voltage into
Photovoltaic System Technology
Photovoltaic System Technology Photovoltaic Cells What Does Photovoltaic Mean? Solar electricity is created using photovoltaic cells (or PV cells). The word photovoltaic is made up of two words: photo
The soot and scale problems
Dr. Albrecht Kaupp Page 1 The soot and scale problems Issue Soot and scale do not only increase energy consumption but are as well a major cause of tube failure. Learning Objectives Understanding the implications
Gunite Disc Brake Rotors
Gunite Disc Brake Rotors Maintenance Manual Gunite is the industry leader in the development of brake system components for heavy-duty truck applications including air disc brake rotors. Gunite was the
OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS
OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS Photoelectric These sensors use light sensitive elements to detect objects and are made up of an emitter (light source) and a receiver. Four types of photoelectric
Tom Wilson Product Marketing Manager Delivery Systems Varian Medical Systems International AG. CERN Accelerator School, May 2015
INDUSTRIAL DESIGN Tom Wilson Product Marketing Manager Delivery Systems Varian Medical Systems International AG VARIAN ONCOLOGY SYSTEMS 1 VARIAN ONCOLOGY SYSTEMS CERN Accelerator, May 2015 Industrial Design
Balzers Sputter Coater SCD 050
Balzers Sputter Coater SCD 050 The SCD 050 is a bench top, sputter deposition system designed for thin films on substrates up to 6 inches. Morphology and thickness is user controlled using power, pressure,
WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS
CONDUCTORS Conductors are needed to complete the path for electrical current to flow from the power source to the working devices and back to the power source. Special wiring is needed for battery cables
Permanent Magnet Motor Kit, Magnetic Reed Type. (SKY-ReedMotorKit) Instructions
Permanent Magnet Motor Kit, Magnetic Reed Type (SKY-ReedMotorKit) Instructions This kit contains powerful permanent magnets. Exercise caution when handling them as they can pull on iron tools and snap
Force on Moving Charges in a Magnetic Field
[ Assignment View ] [ Eðlisfræði 2, vor 2007 27. Magnetic Field and Magnetic Forces Assignment is due at 2:00am on Wednesday, February 28, 2007 Credit for problems submitted late will decrease to 0% after
TRIMMING UNIT/DIAMOND MACHINE TST.13
TRIMMING UNIT/DIAMOND MACHINE TST.13 REFERENCE BOOK rel. 02.15 TRIMMING UNIT/DIAMOND MACHINE TST.13 REL. 02.15 ENGLISH LANGUAGE 1 MACHINE DESCRIPTION TST.13 was designed and built for processing methacrylate.
Seasonal & Daily Temperatures. Seasons & Sun's Distance. Solstice & Equinox. Seasons & Solar Intensity
Seasonal & Daily Temperatures Seasons & Sun's Distance The role of Earth's tilt, revolution, & rotation in causing spatial, seasonal, & daily temperature variations Please read Chapter 3 in Ahrens Figure
Vapor Chambers. Figure 1: Example of vapor chamber. Benefits of Using Vapor Chambers
Vapor Chambers A vapor chamber is a high-end thermal management device that can evenly dissipate heat from a small source to a large platform of area (see Figure 1). It has a similar construction and mechanism
Surface roughness. Picture 1: Friction coefficient as a function of surface roughness Curve 1: Roughness R z 0,5µm Curve 2: Roughness R z 5 µ
Surface roughness It is often erroneously thought that the surface of commutators or slip rings should be brilliant and polished to ensure an optimal performance of carbon brushes. Quite the reverse! Apart
TIG WELDING TIPS by Tom Bell
(This is a two-part document, with general tig welding first followed by one aluminum-specific.) TIG WELDING TIPS by Tom Bell 1. The bigger the rod, the easier it is to feed. Use larger diameter rods (3/32
BUILDING A BASIC CIRCUIT
Teacher Information BUILDING A BASIC CIRCUIT NSES9-12.2 Physical Science: Interactions of Energy and Matter Adaptations Some adaptations and modifications that may assist a student with visual and/or other
Stainless Steel Marking Guide
Stainless Steel Marking Guide Laser Processing Guide: Marking Stainless Steel There are three options available for marking stainless steel: direct mark using a CO 2 laser and High Power Density Focusing
Measurement of Charge-to-Mass (e/m) Ratio for the Electron
Measurement of Charge-to-Mass (e/m) Ratio for the Electron Experiment objectives: measure the ratio of the electron charge-to-mass ratio e/m by studying the electron trajectories in a uniform magnetic
Basics of Electricity
Basics of Electricity Generator Theory PJM State & Member Training Dept. PJM 2014 8/6/2013 Objectives The student will be able to: Describe the process of electromagnetic induction Identify the major components
Tableting Punch Performance Can Be Improved With Precision Coatings
Tableting Punch Performance Can Be Improved With Precision Coatings by Arnold H. Deutchman, Ph. D. Director of Research and Development (614) 873-4529 X 114 [email protected] Mr. Dale C. Natoli
Using and Wiring Light Emitting Diodes (LEDs) for Model Railroads
Using and Wiring Light Emitting Diodes (LEDs) for Model Railroads LEDs have many useful applications in Model railroading, including: Locomotive headlights Rear-end warning lights for cabooses and passenger
Radiographic Grid. Principles of Imaging Science II (RAD 120) Image-Forming X-Rays. Radiographic Grids
Principles of Imaging Science II (RAD 120) Radiographic Grids 1 Image-Forming X-Rays Four X-ray paths a. X-rays interact with patient and scatter away from the receptor b. X-rays interact and are absorbed
JEFFERSON COLLEGE. Radiographic Physics
JEFFERSON COLLEGE COURSE SYLLABUS RAD160 Radiographic Physics 3 Credit Hours Revised by: Janet E. Akers BS RT (R)(M) Date: October 3, 2013 Kenny Wilson, Director, Health Occupation Programs Dena McCaffrey,
Note: You will receive no credit for late submissions. To learn more, read your instructor's Grading Policy
1/7 2009/11/14 上 午 11:10 Manage this Assignment: Chapter 16 Due: 12:00am on Saturday, July 3, 2010 Note: You will receive no credit for late submissions. To learn more, read your instructor's Grading Policy
Survival Laser SL-001BB Laser Parts Bundle Assembly & Operation Instructions
Survival Laser SL-001BB Laser Parts Bundle Assembly & Operation Instructions WARNING: READ ALL INSTRUCTIONS AND THE ENCLOSED SAFETY PRECAUTIONS BEFORE ASSEMBLY AND USE Assemble and use these parts ONLY
7. What is the current in a circuit if 15 coulombs of electric charge move past a given point in 3 seconds? (1) 5 A (3) 18 A (2) 12 A (4) 45 A
1. Compared to the number of free electrons in a conductor, the number of free electrons in an insulator of the same volume is less the same greater 2. Most metals are good electrical conductors because
View of ΣIGMA TM (Ref. 1)
Overview of the FESEM system 1. Electron optical column 2. Specimen chamber 3. EDS detector [Electron Dispersive Spectroscopy] 4. Monitors 5. BSD (Back scatter detector) 6. Personal Computer 7. ON/STANDBY/OFF
Helium-Neon Laser. Figure 1: Diagram of optical and electrical components used in the HeNe laser experiment.
Helium-Neon Laser Experiment objectives: assemble and align a 3-mW HeNe laser from readily available optical components, record photographically the transverse mode structure of the laser output beam,
Displays. Cathode Ray Tube. Semiconductor Elements. Basic applications. Oscilloscope TV Old monitors. 2009, Associate Professor PhD. T.
Displays Semiconductor Elements 1 Cathode Ray Tube Basic applications Oscilloscope TV Old monitors 2 1 Idea of Electrostatic Deflection 3 Inside an Electrostatic Deflection Cathode Ray Tube Gun creates
PS-6.2 Explain the factors that determine potential and kinetic energy and the transformation of one to the other.
PS-6.1 Explain how the law of conservation of energy applies to the transformation of various forms of energy (including mechanical energy, electrical energy, chemical energy, light energy, sound energy,
RICHARD T ELL ASSOCIATES,INC.
RICHARD T ELL ASSOCIATES,INC. An Evaluation of Test Measurement Data Obtained on the KW-Gard RF Protective Suit March 30, 1998 Prepared for Euclid Garment Manufacturing Company 333 Martinel Drive Kent,
COMPARISON OF DRILLING TECHNOLOGIES BETWEEN TOP DRIVE AND ROTARY TABLE IN GEOTHERMAL FIELDS: A CASE STUDY OF OLKARIA GEOTHERMAL FIELDS.
Proceedings 5 th African Rift geothermal Conference Arusha, Tanzania, 29-31 October 2014 COMPARISON OF DRILLING TECHNOLOGIES BETWEEN TOP DRIVE AND ROTARY TABLE IN GEOTHERMAL FIELDS: A CASE STUDY OF OLKARIA
3D Printing LESSON PLAN PHYSICS 8,11: OPTICS
INVESTIGATE RATIONALE Optics is commonly taught through the use of commercial optics kits that usually include a basic set of 2-4 geometric lenses (such as double convex or double concave). These lenses
Roller bearing life. The Reaction of AISI 52100 Bearing Steel to Heat
Roller bearing life in high temperatures A common question maintenance personnel ask bearing companies when their equipment temperature is high or rises is, What is the maximum temperature that your rolling
X-Ray Diffraction HOW IT WORKS WHAT IT CAN AND WHAT IT CANNOT TELL US. Hanno zur Loye
X-Ray Diffraction HOW IT WORKS WHAT IT CAN AND WHAT IT CANNOT TELL US Hanno zur Loye X-rays are electromagnetic radiation of wavelength about 1 Å (10-10 m), which is about the same size as an atom. The
Tech Bulletin. Understanding Solar Performance
Tech Bulletin Understanding Solar Performance Bekaert solar control window films use advanced technology to benefit consumers with quality solutions that enhance comfort and decrease energy use. By understanding
Magnetic Deburring & Polishing Machine
Magnetic Deburring & Polishing Machine Operation Manual Models: EHD-750CL, 766, 735, 728, 716, 715 1 Index 1. Before Starting to Use the spinner 2. Functions 3. Features 4. Applications 5. Principle of
Laserlyte-Flex Alignment System
Laserlyte-Flex Alignment System LaserLyte-Flex The LaserLyte-Flex Alignment System is a unique, interchangeable, low cost plug and play laser system. Designed specifically for aligning and positioning
Coating Technology: Evaporation Vs Sputtering
Satisloh Italy S.r.l. Coating Technology: Evaporation Vs Sputtering Gianni Monaco, PhD R&D project manager, Satisloh Italy 04.04.2016 V1 The aim of this document is to provide basic technical information
Energy Transformation Lab
Energy Transformation Lab Lab Response Page You will fill in the blanks with the energy form that matches that object. Use thermal instead of heat and radiant instead of light. You may double check your
UNIVERSITY OF SASKATCHEWAN Department of Physics and Engineering Physics
UNIVERSITY OF SASKATCHEWAN Department of Physics and Engineering Physics Physics 111.6 MIDTERM TEST #4 March 15, 2007 Time: 90 minutes NAME: (Last) Please Print (Given) STUDENT NO.: LECTURE SECTION (please
Chapter 18 Temperature, Heat, and the First Law of Thermodynamics. Problems: 8, 11, 13, 17, 21, 27, 29, 37, 39, 41, 47, 51, 57
Chapter 18 Temperature, Heat, and the First Law of Thermodynamics Problems: 8, 11, 13, 17, 21, 27, 29, 37, 39, 41, 47, 51, 57 Thermodynamics study and application of thermal energy temperature quantity
Students will investigate the characteristics of electromagnetism and then use what they learn to plan and conduct an experiment on electromagnets.
Electromagnetic Power! Lesson Overview Students will investigate the characteristics of electromagnetism and then use what they learn to plan and conduct an experiment on electromagnets. Suggested Grade
Handling Corrosive or Abrasive Liquids
Handling Corrosive or Abrasive Liquids Defining abrasion and corrosion An abrasive liquid is one that has particles in it. Some, like inks, have very fine particles, while others, like some paints, contain
RESULTS OF ICARUS 9 EXPERIMENTS RUN AT IMRA EUROPE
Roulette, T., J. Roulette, and S. Pons. Results of ICARUS 9 Experiments Run at IMRA Europe. in Sixth International Conference on Cold Fusion, Progress in New Hydrogen Energy. 1996. Lake Toya, Hokkaido,
Unit 6: EXTRUSION. Difficult to form metals like stainless steels, nickel based alloys and high temperature metals can also be extruded.
1 Unit 6: EXTRUSION Introduction: Extrusion is a metal working process in which cross section of metal is reduced by forcing the metal through a die orifice under high pressure. It is used to produce cylindrical
Theory of Heating by Induction
CHAPTER 2 Theory of Heating by Induction INDUCTION HEATING was first noted when it was found that heat was produced in transformer and motor windings, as mentioned in the Chapter Heat Treating of Metal
BB-18 Black Body High Vacuum System Technical Description
BB-18 Black Body High Vacuum System Technical Description The BB-18 Black Body is versatile and is programmed for use as a fixed cold target at 80 K or variable target, at 80 K- 350 K no extra cost. The
