Modular Data Center Cooling. Ultra High Efficiency. Oasis Optimum DCIE
|
|
|
- Doreen Shauna Gaines
- 10 years ago
- Views:
Transcription
1 Modular Data Center Cooling Ultra High Efficiency Oasis Optimum DCIE
2 Oasis Optimum Modular Cooling Compact, Economic, Greener, Ultra High Efficiency Munters Oasis Optimum DCIE data center cooling solution focuses on energy efficiency. The modular design allows owners and operators clear budget optimization at the outset of a new data center build and follows LEED design concepts. High energy efficiency and sustainability mean lower capital expenditure in addition to significantly lower annual operating cost. Backed by our experienced in-house data center teams, Munters has designed and built hundreds of cooling systems for collocation, government, education and commercial clientelle. Flexible Data Center Cooling Solutions - the right choice The heart of the Oasis Optimum DCIE cooling system is the Munters patented Evaporative Polymer Exchanger (EPX), which provides ultra-high efficiency cooling while using up to 75% less energy than traditional high efficiency systems. In many cases the Oasis Optimum DCIE can meet all the cooling needs of a data center. The Oasis Optimum DCIE can help data centers reach ppue values below 1.1. The system is scalable in increments of 200kW* and the modules can simply be added on as your data center grows. This flexible aspect makes for the best choice in providing supplemental cooling or replacement of less efficient equipment on existing data centers. The Oasis Optimum DCIE is future-proof, and can easily accommodate advances in server technology and operating conditions. *IT heat rejection capacity depends on the operating temperatures of the data center. Typical Base Unit
3 Proven technology - outstanding quality The Oasis Optimum DCIE cooling system incorporates Munters innovative UL listed Oasis Indirect Evaporative Cooling technology for energy efficient cooling. This patented system uses an air-to-air heat exchanger to transfer data center heat to a separate outdoor airstream. Fresh outdoor air is drawn across polymer heat exchanger tubes which are wetted with a water spray. While filtered ambient air - scavenger air - flows over the saturated exterior tube surface, the evaporative heat transfer process efficiently cools hot aisle air flowing through the inside of the tubes. The award-winning design of the Oasis Indirect Evaporative Cooler ensures 100% of the data center air is recirculated and uncontaminated in order to provide a clean, stable IT environment. Munters are winners of the 2012 Future Thinking and Design Concepts Award. Principle of Operation Exhaust / Scavenger Air Optional Condenser Optional Coil Compressor Vestibule Cooled air is ducted back to data center for heat extraction Hot Aisle Return Air Scavenger Outside Air Cold Aisle Supply Air Hot Aisle Return Air Optional Cooling Coil (DX or CHW) Hot data center air enters EPX Polymer tube for sensible dry cooling by the evaporating water film on tube exterior Scavenger air flows up and around outside of tubes having extracted heat from air flowing inside tubes The systems have three modes of operation A: Sensible/Dry Mode B: Evaporating/Wet Mode C: Evaporating and supplementary Mechanical Cooling. Visit: res or watch the movie now:
4 Oasis Innovative Evaporative Cooling Systems These highly energy efficient and scalable units are factory-built incorporating plug & play technology, and requiring minimal work on site Consistently low ppue s accross variable loads Matches airflow to actual IT demand. ppue s remain consistently low whether the data center is partially or fully operating at 100% capacity. Resilience: Built to meet zone A1 and A2 ASHRAE standard through to Tier 4 levels of resilience with N+1 components if required. Financial: Significantly lower operational expenditure compared to traditional data center cooling solutions Flexibility Unit designed to be leaded easily using ISO 40ft containers, the truly flexible design will be fully configured and scaleable to suit your installation and capacity requirements. New Innovative Approach that delivers added capacity The Oasis Optimum DCIE has three modes of operation for low energy data center cooling which primarily utilizes free cooling. In the optimized mode natural forces are harnessed by adding water for indirect evaporative cooling to boost cooling. The filtered, ambient air is principaly cooled with indirect evaporative cooling. This saves siginificant amounts of money and carbon emissions. The third mode deploys mechanical cooling. The system is designed to achieve maximum efficiency. Munters Oasis Indirect Evaporative Cooling systems enable the IT equipment to be cooled to air temperatures of below 27 C/80.6 F (ASHRAE thermal guidelines for data processing environments 2009a) for more than 99% of the time without the need for mechnical cooling across a range of IT loads depending on the location. The supplementary mechnical cooling system is only used for additional cooling during extreme weather conditions. Enables up to 75% reduction in energy consumption vs. traditional data cooling ppue. National, European and International patents cover this innovative technology.
5 Standard Oasis Optimum DCIE - Standard Design (consult Munters for exact performance based on your location) Design System Cooling Capacity ITE Heat Rejection Delta T (return to supply) Heat rejection capacity depends on design 155 kw 20 F / 11.1 C supply & return temperatures 195 kw 25 F / 13.9 C 235 kw 30 F / 16.7 C Supply Air Volume per Unit 25,000 SCFM 40,000 m 3 /hr Base unit with end connections LxWxH & Weight 294 x88 x mm x 2235mm x 3854mm 13,000 lbs 5,910 kg Base unit with bottom connections inc. Roof mount option LxWxH & Weight Base unit with end connections and return plenum, inc. side mount-stacked-option LxWxH & Weight 342 x 88 x mm x 2235mm x 3854mm 16,000 lbs 7,257 kg 294 x88 x mm x 2235mm x 5382mm 16,000 lbs 7,257 kg Mechanical cooling based on 75 F / 23.9 C supply temperature and 100 F / 37.8 C return temperature Mechanical Cooling Options Design ambient wet bulb temperature Delta T 75 F /23.9 C 80 F / 26.7 C 85 F / 29.4 C 90 F / 32.2 C DX 20 tons / 70 kw 20 F /11 C 13 tons /46 kw 20 tons /72 kw 28 tons /100 kw 36 tons /128 kw DX 30 tons / 105 kw 25 F /13.9 C 16 tons /56 kw 23 tons /82 kw 31 tons /110 kw 39 tons /138 kw DX 40 tons / 140 kw 30 F /16.7 C 19 tons /67 kw 26 tons /92 kw 34 tons /120 kw 42 tons /148 kw Note: Base unit can be selected without Mechanical DX based cooling option Location Shanghai, China Design Ambient dry bulb / extreme max wet bulb 100 F / 86.2 F 37.8 C / 30.1 C External Static Pressure 1.0in WC 250 Pa Case 1 Base design ITE Load 780 kw Cold Aisle supply/hot Aisle return 75 F / 100 F 23.9 C / 37.8 C Case 2 ASHRAE Recommended ITE Load 940 kw Cold Aisle supply/hot Aisle return 80 F / 110 F 26.7 C / 43.3 C Performance per Oasis unit at extreme max wb design Total Oasis Annual Performance Case 1 N=4, N+1 Redundancy, all units operating Case 2 N=4, N+1 Redundancy, all units operating *includes fan heat IT Load kw Oasis EPX Cooling tons/kw % Total Cooling* DX Cooling tons/kw % Total Cooling* Estimated Operating Power kw Estimated Annual Water Consumption Specification subject for change without prior notice Estimated Annual Energy Use Annual ppue /74 45% 26/92 55% ,000 ft 3 /6300 m 3 650,000 kwh /123 63% 22/76 37% ,000 ft 3 /7900 m 3 600,000 kwh 1.07
6 Examples of possible installations Base Oasis - End Connections - Flexible installation location Base Oasis - Bottom connection - Suits roof installation Base Oasis - End connection with return plenum - Suits perimeter install beside data hall High quality and precision factory production Oasis Optimum DCIE cooling system construction takes place in a dust free, spacious environment to allow comprehensive pre-site testing. Quality control is improved as all electrical systems are comprehensivley tested in the factory before the Oasis Optimum DCIE is delivered to site for final connection and further testing to ensure operation. This partial factory commissioning services/control system testing provides added supply security. Munters Corporation has been recognised for Intel Corporation s Preferred Quality Supplier (PQS) award for VOC and energy efficient air handling equipment.
7 Oasis Optimum DCIE These modular indirect evaporative cooling systems are robust and durable and can be delivered in a shorter time. The specially designed standardized modules have higher optimized engineering and maintenance access. Self-contained and shipped in a standard 40ft shipping container (to be returned) Multiple configurations to address varying IT and site requirements Latest data center indirect evaporative cooling innovation Proven experience in over 170MW of data center cooling Delivers industry-leading energy efficient cooling Industry leading ppue rating Designed to reduce data center cooling costs, deployment times and maintenance Oasis Optimum DCIE is an excellent option for either supplementing or replacing traditional data center cooling systems. Annual hours where Oasis Indirect Evaporative Cooler provides 27 C /81 F cold aisle supply based on hot aisle return air temperature of 39 C/102 F London Paris Berlin Shanghai Madrid Stockholm Hours run with Oasis EPX only Beijing Tokyo Moscow Istanbul Los Angeles Boston Lanzhou Hours run with Oasis EPX and supplementary cooling Sapporo Gwangju
8 An international name, where the customer comes first. Munters, part of Nordic Capital, has offices in 30 countries and over 3,000 employees in many branches around the world. We are global leaders in energy efficient air treatment for comfort, process and environmental protection. Munters shares ideas within its international network, giving the Group an outstanding reputation as a reliable, fastacting and customer-orientated expert in air conditioning. Munters philosophy of customer satisfaction is central to our decision-making. When developing and manufacturing our systems, we see happy customers as our number one target. And this is what our employees strive to ensure every day. For more information on Munters, please visit Australia Phone , [email protected] Austria Phone , luftentfeuchtung@ munters.at Belgium Phone , [email protected] Brazil Phone , [email protected] Canada Phone , [email protected] China Phone , [email protected] Czech Republic Phone , [email protected] Denmark Phone , [email protected] Finland Phone , [email protected] France Phone , [email protected] Germany Phone , [email protected] India Phone , [email protected] Italy Phone , [email protected] Japan Phone ,[email protected] Korea , munters@munters. co.kr Mexico Phone , [email protected] Netherlands Phone , [email protected] Poland Phone , [email protected] Singapore Phone , [email protected] South Africa Phone , [email protected] Spain Phone , [email protected] Sweden Phone , [email protected] Switzerland Phone , [email protected] Thailand Phone , [email protected] Turkey Phone , [email protected] UAE , [email protected] United Kingdom Phone , [email protected] USA Phone , [email protected] Vietnam Phone , [email protected] Your local office
OASIS PRODUCT GUIDE. Data Centre Cooling INDIRECT EVAPORATIVE COOLER. Data Centres. Telecoms. EPX technology. Class leading performance
OASIS PRODUCT GUIDE Data Centres Telecoms EPX technology Class leading performance Fully configurable solutions INDIRECT EVAPORATIVE COOLER Data Centre Cooling 2 MUNTERS.COM/DATACENTRES Critical cooling
Data Centre Cooling Technologies. Jon Pettitt, EMEA DataCenter Business Development Manager
Data Centre Cooling Technologies 1 Jon Pettitt, EMEA DataCenter Business Development Manager Munters Group Key facts 3.000 Employees 30 Countries Turnover of 470 M HQ in Sweden Global DC Support 25+ Data
HVAC Infrastructure Retrofit Solutions
Kyoto Cooling Lunch & Learn David Belleville, APA LLC March 9, 2015 Owners choose APA solutions to: Rely on our 30+ years of delivering engineered solutions; HVAC Infrastructure Retrofit Solutions Insure
Reduce data center PUE using Munters innovative cooling solutions
d a t a center applica t i o n guide Reduce data center PUE using Munters innovative cooling solutions Reduce data center energy costs by up to 75% Traditional refrigeration cooling systems are an inefficient
Indirect Evaporative Cooling (IDEC) Unit for Data Centers
Indirect Evaporative Cooling (IDEC) Unit for Data Centers NORTEK AIR SOLUTIONS Cool3 IDEC UNIT INDIRECT EVAPORATIVE COOLING The new Nortek Air Solutions Cool 3 IDEC unit is a proven approach for highly
Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages
Objectives Increase awareness of the types of economizers currently used for data centers Provide designers/owners with an overview of the benefits and challenges associated with each type Outline some
Elements of Energy Efficiency in Data Centre Cooling Architecture
Elements of Energy Efficiency in Data Centre Cooling Architecture Energy Efficient Data Center Cooling 1 STULZ Group of Companies Turnover 2006 Plastics Technology 400 Mio A/C Technology 200 Mio Total
Climate solutions. evaporative cooling, adiabatic humidification and programmable controllers. energy saving solutions for data centers. carel.
Climate solutions evaporative cooling, adiabatic humidification and programmable controllers energy saving solutions for data centers carel.com Data center air-conditioning Data center air-conditioning
Excool Indirect Adiabatic and Evaporative Data Centre Cooling. World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling
Excool Indirect Adiabatic and Evaporative Data Centre Cooling World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling Indirect Adiabatic and Evaporative Data Centre Cooling Solutions by
DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER
DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER DATA CENTERS 2009 IT Emissions = Aviation Industry Emissions Nations Largest Commercial Consumers of Electric Power Greenpeace estimates
Data Center Heat Rejection
This article was published in ASHRAE Journal, March 2011. Copyright 2011 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. Posted at www.ashrae.org. This article may not be
Analysis of data centre cooling energy efficiency
Analysis of data centre cooling energy efficiency An analysis of the distribution of energy overheads in the data centre and the relationship between economiser hours and chiller efficiency Liam Newcombe
Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling
Data Center Design Guide featuring Water-Side Economizer Solutions with Dynamic Economizer Cooling Presenter: Jason Koo, P.Eng Sr. Field Applications Engineer STULZ Air Technology Systems jkoo@stulz ats.com
International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS
International Telecommunication Union ITU-T TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU Technical Paper (13 December 2013) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES
by knürr CoolTherm Server cabinet technology with outstanding benefits up to 35kW cooling capacity Blade-Server server optimized! www.knuerr.
HIGH DENSITY COOLING SOLUTIONS by knürr CoolTherm Server cabinet technology with outstanding benefits up to 35kW cooling capacity Blade-Server server optimized! optimiert! Setting benchmarks. Being the
Energy Efficient Server Room and Data Centre Cooling. Computer Room Evaporative Cooler. EcoCooling
Energy Efficient Server Room and Data Centre Cooling Computer Room Evaporative Cooler EcoCooling EcoCooling CREC Computer Room Evaporative Cooler Reduce your cooling costs by over 90% Did you know? An
Defining Quality. Building Comfort. Precision. Air Conditioning
Defining Quality. Building Comfort. Precision Air Conditioning Today s technology rooms require precise, stable environments in order for sensitive electronics to operate optimally. Standard comfort air
APC APPLICATION NOTE #112
#112 Best Practices for Deploying the InfraStruXure InRow SC By David Roden Abstract The InfraStruXure InRow SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets.
Liebert EFC from 100 to 350 kw. The Highly Efficient Indirect Evaporative Freecooling Unit
Liebert EFC from 100 to 350 kw The Highly Efficient Indirect Evaporative Freecooling Unit Liebert EFC, the Highly Efficient Indirect Evaporative Freecooling Solution Emerson Network Power delivers innovative
Direct Fresh Air Free Cooling of Data Centres
White Paper Introduction There have been many different cooling systems deployed in Data Centres in the past to maintain an acceptable environment for the equipment and for Data Centre operatives. The
AERIS DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM
DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM THE GLOBAL DATA CENTRE MARKET The data centre air conditioning market is expected to grow with a CAGR (compound annual growth rate) of about 12% in the next
IEC DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM
DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM THE GLOBAL DATA CENTRE MARKET The data centre air conditioning market is expected to grow with a CAGR (compound annual growth rate) of about 12% in the next
41 T Korea, Rep. 52.3. 42 T Netherlands 51.4. 43 T Japan 51.1. 44 E Bulgaria 51.1. 45 T Argentina 50.8. 46 T Czech Republic 50.4. 47 T Greece 50.
Overall Results Climate Change Performance Index 2012 Table 1 Rank Country Score** Partial Score Tendency Trend Level Policy 1* Rank Country Score** Partial Score Tendency Trend Level Policy 21 - Egypt***
Global Real Estate Outlook
Global Real Estate Outlook August 2014 The Hierarchy of Economic Performance, 2014-2015 China Indonesia India Poland South Korea Turkey Australia Mexico United Kingdom Sweden United States Canada South
IBM Portable Modular Data Center Overview for Critical Facilities Round Table
Brian Canney Global Services Executive, IBM GTS Site and Facilities Services April 2011 IBM Portable Modular Data Center Overview for Critical Facilities Round Table 2009 IBM Corporation Key messages Containers
Bring the fresh in. Dedicated Outside Air Systems
Bring the fresh in. Dedicated Outside Air Systems The inside story on outside air. On average, we breathe in 3,400 gallons of air each day. Ambient indoor air pollution is a major problem, affecting health
Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund
Income INTECH Global Income Managed Volatility Fund Australia 0.0066 0.0375 Austria 0.0045 0.0014 Belgium 0.0461 0.0138 Bermuda 0.0000 0.0059 Canada 0.0919 0.0275 Cayman Islands 0.0000 0.0044 China 0.0000
How to Save Over 60% on Cooling Energy Needed by a Data Center? The Roadmap from Traditional to Optimized Cooling
How to Save Over 60% on Cooling Energy Needed by a Data Center? The Roadmap from Traditional to Optimized Cooling Abstract Data center managers are increasingly in search of methods and technologies for
Free Cooling for Data Centers
Free Cooling for Data Centers Release 1, September 2015 Contents 1. Abstract... 3 2. Introduction... 3 3. Data Center Temperatures and Free Cooling... 4 4. Direct Free Cooling... 4 5. Indirect Free Cooling...
CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers
CURBING THE COST OF DATA CENTER COOLING Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers OVERVIEW Compare Cooling Strategies in Free- Standing and In-Building
How To Improve Energy Efficiency Through Raising Inlet Temperatures
Data Center Operating Cost Savings Realized by Air Flow Management and Increased Rack Inlet Temperatures William Seeber Stephen Seeber Mid Atlantic Infrared Services, Inc. 5309 Mohican Road Bethesda, MD
III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014
III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014 III.1. Large Roof Mount PN: 89-3037 Roof Mount Unit Eco 136 Parallel roof mount Air-conditioning and ventilation systems The Eco 136
Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions
Free Cooling in Data Centers John Speck, RCDD, DCDC JFC Solutions Why this topic Many data center projects or retrofits do not have a comprehensive analyses of systems power consumption completed in the
Compared assessment of selected environmental indicators of photovoltaic electricity in OECD cities
Compared assessment of selected environmental indicators Electricity production based on solar photovoltaic (PV) technology is pollution-free at the local as well as the global level, it does not emit
Excool Data Centre Cooling Product Comparison Report
Excool Data Centre Cooling Product Comparison Report Desktop Study Job No: 1003780 Date: October 2011 Cundall Johnston and Partners LLP Saffron House 6-10 Kirby Street London EC1N 8TS tel 020 7438 1600
Make the invisible visible! SENSORS WITH EXCELLENT BACKGROUND SUPPRESSION
Make the invisible visible! SENSORS WITH EXCELLENT BACKGROUND SUPPRESSION photoelectric sensors Thanks to its vision for innovation and technological enhancement, Contrinex keeps on setting new standards
AIRAH Presentation April 30 th 2014
Data Centre Cooling Strategies The Changing Landscape.. AIRAH Presentation April 30 th 2014 More Connections. More Devices. High Expectations 2 State of the Data Center, Emerson Network Power Redefining
National Grid Your Partner in Energy Solutions
National Grid Your Partner in Energy Solutions National Grid Webinar: Enhancing Reliability, Capacity and Capital Expenditure through Data Center Efficiency April 8, 2014 Presented by: Fran Boucher National
HVAC Systems: Overview
HVAC Systems: Overview Michael J. Brandemuehl, Ph.D, P.E. University of Colorado Boulder, CO, USA Overview System Description Secondary HVAC Systems Air distribution Room diffusers and air terminals Duct
IT Cooling Solutions. DFC² Direct Free Cooling for Data Centres. Energy-efficient, reliable and available around the world
IT Cooling Solutions DFC² Direct Free Cooling for Data Centres Energy-efficient, reliable and available around the world Worldwide Green Engineering with Direct Free Cooling from STULZ Forward thinking
Data Centre Cooling Air Performance Metrics
Data Centre Cooling Air Performance Metrics Sophia Flucker CEng MIMechE Ing Dr Robert Tozer MSc MBA PhD CEng MCIBSE MASHRAE Operational Intelligence Ltd. [email protected] Abstract Data centre energy consumption
Improving Data Center Energy Efficiency Through Environmental Optimization
Improving Data Center Energy Efficiency Through Environmental Optimization How Fine-Tuning Humidity, Airflows, and Temperature Dramatically Cuts Cooling Costs William Seeber Stephen Seeber Mid Atlantic
COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers
COMMERCIAL HVAC CHILLER EQUIPMENT Air-Cooled Chillers Technical Development Programs (TDP) are modules of technical training on HVAC theory, system design, equipment selection and application topics. They
World Consumer Income and Expenditure Patterns
World Consumer Income and Expenditure Patterns 2014 14th edi tion Euromonitor International Ltd. 60-61 Britton Street, EC1M 5UX TableTypeID: 30010; ITtableID: 22914 Income Algeria Income Algeria Income
Configuring DHCP for ShoreTel IP Phones
Configuring DHCP for ShoreTel IP Phones Network Requirements and Preparation 3 Configuring DHCP for ShoreTel IP Phones The ShoreTel server provides the latest application software and configuration information
System solution for data centres
1 System solution for data centres Energy-efficient air conditioning with ServeLine Cooling IT infrastructure, high availability, low energy costs and communication with DCIM systems all in one from your
The New Data Center Cooling Paradigm The Tiered Approach
Product Footprint - Heat Density Trends The New Data Center Cooling Paradigm The Tiered Approach Lennart Ståhl Amdahl, Cisco, Compaq, Cray, Dell, EMC, HP, IBM, Intel, Lucent, Motorola, Nokia, Nortel, Sun,
How To Get A New Phone System For Your Business
Cisco Phone Systems Telemarketing Script Cold Call 1. Locate Contact: Name listed Owner General Manager / Office Manager Chief BDM (Business Decision Maker) Note: Avoid talking to IT since this is not
How High Temperature Data Centers and Intel Technologies Decrease Operating Costs
Intel Intelligent Management How High Temperature Data Centers and Intel Technologies Decrease Operating Costs and cooling savings through the use of Intel s Platforms and Intelligent Management features
Cisco Blended Agent: Bringing Call Blending Capability to Your Enterprise
DATA SHEET Cisco Blended Agent: Bringing Call Blending Capability to Your Enterprise Cisco ICM software has traditionally enabled companies to distribute inbound service volume to a variety of termination
IT Cooling Solutions. DFC² Direct Free Cooling for Data Centres. Energy-efficient, reliable and available around the world
IT Cooling Solutions DFC² Direct Free Cooling for Data Centres Energy-efficient, reliable and available around the world Worldwide Green Engineering with Direct Free Cooling from STULZ Forward thinking
STULZ Water-Side Economizer Solutions
STULZ Water-Side Economizer Solutions with STULZ Dynamic Economizer Cooling Optimized Cap-Ex and Minimized Op-Ex STULZ Data Center Design Guide Authors: Jason Derrick PE, David Joy Date: June 11, 2014
Breakthrough Solenoid Valve Technology for Upstream Oil and Gas Heating Equipment
Breakthrough Solenoid Valve Technology for Upstream Oil and Gas Heating Equipment by Bob Cadwell, Gerry Longinetti, and James Chiu A White Paper From ASCO Introduction Low-temperature stainless steel fuel
Paul Oliver Sales Director. Paul Oliver, Airedale Tom Absalom, JCA
Paul Oliver Sales Director Paul Oliver, Airedale Tom Absalom, JCA Airedale an overview 25,000m 2 UK premier test centre 450 staff Global distribution A Modine company Modine centre of excellence Airedale
By Tom Brooke PE, CEM
Air conditioning applications can be broadly categorized as either standard or critical. The former, often called comfort cooling, traditionally just controlled to maintain a zone setpoint dry bulb temperature
products 22 º C Ventilation Air Conditioning Refrigeration Energy & Cost Saving Products Inside PROVIDED BY HEINEN & HOPMAN
products > Energy & Cost Saving Products OUTSIDE 35 C HUMIDITY 90% 22 º C Inside PROVIDED BY HEINEN & HOPMAN Heating Ventilation Air Conditioning Refrigeration HVAC energy & COST SAVING POSSIBILITIES A
2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms
Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms Agenda Review of cooling challenge and strategies Solutions to deal with wiring closet cooling Opportunity and value Power
AVOIDING BUSINESS RISK: THE HIDDEN BENEFIT OF SOFTWARE AS A SERVICE
AVOIDING BUSINESS RISK: THE HIDDEN BENEFIT OF SOFTWARE AS A SERVICE AVOIDING BUSINESS RISK: THE HIDDEN BENEFIT OF SOFTWARE AS A SERVICE Software as a Service (SaaS) is now the predominant architecture
- White Paper - Data Centre Cooling. Best Practice
- White Paper - Data Centre Cooling Best Practice Release 2, April 2008 Contents INTRODUCTION... 3 1. AIR FLOW LEAKAGE... 3 2. PERFORATED TILES: NUMBER AND OPENING FACTOR... 4 3. PERFORATED TILES: WITH
Cisco Conference Connection
Data Sheet Cisco Conference Connection Cisco IP Communications a comprehensive system of powerful, enterprise-class solutions including IP telephony, unified communications, IP video/audio conferencing,
HIGH EFFICIENCY RTU. www.reznorhvac.com HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons
Capacities 10-25 Tons 100-400 MBH HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING DX System IEER> 13.2 Gas Heat Efficiency > 92% HIGH EFFICIENCY RTU 30-120 kw 3,000-11,550 CFM Comfort Comfort is determined
Critical Infrastructure for the World s Leading Data Centers
Critical Infrastructure for the World s Leading Data Centers 2 YOU MAY KNOW US BY OUR BRAND NAMES THE EXPERTISE OF MANY. THE POWER OF ONE. Nortek Air Solutions provides critical infrastructure for the
Premium Data Centre Europe - 2012 Pricing, Business Model & Services
Premium Data Centre Europe - 2012 Pricing, Business Models & Services Premium Data Centre Europe - 2012 Pricing, Business Model & Services Table of Contents A list of figures used in this report 5 Methodology
Industry Service Line 9 ABeam Consulting has developed a proprietary network utilizing the strengths of being Asia based. We provide service that fits the local conditions to clients in every region and
RPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
TOWARDS PUBLIC PROCUREMENT KEY PERFORMANCE INDICATORS. Paulo Magina Public Sector Integrity Division
TOWARDS PUBLIC PROCUREMENT KEY PERFORMANCE INDICATORS Paulo Magina Public Sector Integrity Division 10 th Public Procurement Knowledge Exchange Platform Istanbul, May 2014 The Organization for Economic
European Code of Conduct for Data Centre. Presentation of the Awards 2014
European Code of Conduct for Data Centre Presentation of the Awards 2014 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport 1 The Code of Conduct for Data Centre Results European
CoolTeg Plus Chilled Water (CW) version: AC-TCW
version: 12-04-2013 CONTEG DATASHEET TARGETED COOLING CoolTeg Plus Chilled Water (CW) version: AC-TCW CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420
Webinar: Precision Cooling in Data Centres and other applications 24 June 2014
Webinar: Precision Cooling in Data Centres and other applications 24 June 2014 Jeremy Towler - Senior Manager Energy & Smart Technologies David Garwood Researcher Air-conditioning solutions Helen Bedford
Get the benefits of Norgren s unique range of Online services
Get the benefits of Norgren s unique range of Online services Make your job easier and save time - everything you need to select, design and purchase Norgren pneumatics is in one convenient location, available
CRITICAL COOLING FOR DATA CENTERS
IDEA 100 th Annual Conference & Trade Show CRITICAL COOLING FOR DATA CENTERS Presented by Ron Johanning, PE, LEED AP Mission Critical Market Leader Agenda EPA Report Data Center Energy Trends IT Best Practice
Knowledge for optimal efficiency
Engineering Onboard Climate Control Knowledge for optimal efficiency MARINE HVAC-R MARINE HVAC-R ADVANTAGES 2 KNOWLEDGE FOR OPTIMAL EFFICIENCY The BRONSWERK Advantage It s like the ideal day at sea when
Accuracy counts! SENSORS WITH ANALOG OUTPUT
Accuracy counts! SENSORS WITH ANALOG OUTPUT OTHER APPLICATIONS: KEY ADVANTAGES: Distance measurement Positioning Profile detection Deformation monitoring Vibration monitoring Process monitoring Detection
Element D Services Heating, Ventilating, and Air Conditioning
PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer
NEW LMS 400. The LMS 400 Laser Measurement System Pole position for robotics and material handling. Product Information
NEW LMS 400 Product Information The LMS 400 Laser Measurement System Pole position for robotics and material handling. LMS 400 Moving faster with more precision and reliability The LMS 400 Laser Measurement
CASE STUDY. Environnement S.A. Industrial Site Noise Monitoring
CASE STUDY Environnement S.A. Industrial Site Noise Monitoring France Environmental Noise Monitoring Terminals Environnement S.A., based outside Paris, France, is a cutting edge company in the environmental
Legacy Data Centres Upgrading the cooling capabilities What are the options?
Legacy Data Centres Upgrading the cooling capabilities What are the options? Presentation Structure What is a Legacy Data Centre? What is CRAC cooling? ASHRAE Standards Overview Available Cooling Systems
Capgemini UK Infrastructure Outsourcing
Together. Free your energies Capgemini UK Infrastructure Outsourcing Project Arthur Improved Data Centre Efficiency Paul Feeney Capgemini Tony Mills Spie Matthew Hall Project Arthur The Toltec data centre,
Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: www.cruptime.com Uptime Racks: www.uptimeracks.com
Cooling Small Server Rooms Can Be Inexpensive, Efficient and Easy - Jim Magallanes Computer Room Uptime: www.cruptime.com Uptime Racks: www.uptimeracks.com Server Rooms Description & Heat Problem Trends
FOCUS ON THE ENVIRONMENT
FOCUS ON THE ENVIRONMENT Demystify recycling: easy tips to environmental stewardship Part 1 in a series of 3 Responsibility is simple with HP When it comes to the environment, everyone wants to act responsibly.
Building Technologies
Building Technologies : simple and secure danger management. Integration increases security! The increasing danger potential for people and assets makes the need for better protection increasingly more
Supplies 1. Toner cartridges. Printing. Using color. Paper handling. Maintenance. Troubleshooting. Administration. Index
Toner cartridges Supplies 1 Warning: Do not touch the cartridge roller located under the cover. Cover Your printer uses four separate toner cartridges, one for each color: cyan, yellow, magenta, and black.
Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures
Data Realty Colocation Data Center Ignition Park, South Bend, IN Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures Project Overview Data Realty is a data center service provider for middle
Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools
Heat Recovery Dehumidification (HRD) system Designed for municipal swimming pools A dehumidification and ventilation system with dynamic heat pump heat recovery to swimming pool water and air ENVIRONMENTAL
Building on +60 GW of experience. Track record as of 31 December 2013
Building on +60 GW of experience Track record as of 31 December 2013 Can data and analysis make a difference on turbine performance? Proven technology. For Vestas, it is more than a saying it is something
Reporting practices for domestic and total debt securities
Last updated: 4 September 2015 Reporting practices for domestic and total debt securities While the BIS debt securities statistics are in principle harmonised with the recommendations in the Handbook on
NI USB-6008/6009 OEM USER GUIDE
USER GUIDE NI USB-6008/6009 OEM This document provides information about the dimensions, connectors, and other components of the National Instruments USB-6008/6009 OEM device. For more information about
AERMEC DATA CENTRE SOLUTIONS THE COMPLETE RANGE OF AERMEC SOLUTIONS FOR DATA CENTRES
AERMEC DATA CENTRE SOLUTIONS THE COMPLETE RANGE OF AERMEC SOLUTIONS FOR DATA GLOBAL DATA CENTRE IP TRAFFIC WILL TRIPLE WITHIN 5 YEARS Global data centre IP traffic has set a constant growth path, with
HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation. Richard Lord Carrier Fellow
HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation Richard Lord Carrier Fellow HVAC Industry Challenges and Issues Ozone Deletion Global Warming
MAUVE GROUP GLOBAL EMPLOYMENT SOLUTIONS PORTFOLIO
MAUVE GROUP GLOBAL SOLUTIONS PORTFOLIO At Mauve Group, we offer a variety of complete employee management services such as Global Employment Solutions (GES), Professional Employment Outsourcing (PEO),
DSV Air & Sea, Inc. Aerospace Sector. DSV Air & Sea, Inc. Aerospace
DSV Air & Sea, Inc. Aerospace Sector DSV Air & Sea, Inc. Aerospace Introduction to DSV DSV is a global supplier of transport and logistics services. We have offices in more than 70 countries and an international
Water cooled chiller plant (cp/vs)
Data Center Water cooled chiller plant (cp/vs) Design Envelope File No: 9.573 Date: december 16, 2014 Supersedes: 9.573 Date: november 14, 2014 design envelope s performance improvements are among the
State of the Art Energy Efficient Data Centre Air Conditioning
- White Paper - State of the Art Energy Efficient Data Centre Air Conditioning - Dynamic Free Cooling - Release 2, April 2008 Contents ABSTRACT... 3 1. WHY DO I NEED AN ENERGY EFFICIENT COOLING SYSTEM...
Cisco IOS Public-Key Infrastructure: Deployment Benefits and Features
Data Sheet Cisco IOS Public-Key Infrastructure: Deployment Benefits and Features Introduction to Public Key Infrastructure Public Key Infrastructure (PKI) offers a scalable method of securing networks,
How many students study abroad and where do they go?
From: Education at a Glance 2012 Highlights Access the complete publication at: http://dx.doi.org/10.1787/eag_highlights-2012-en How many students study abroad and where do they go? Please cite this chapter
International Health Solutions. Worldwide Healthcare Plan
Worldwide Healthcare Plan 37 subsidiaries Argentina, Austria, Bahamas, Belgium, Brazil, Canada, Chad, Chile, China, Congo, Czech Republic, France, French Polynesia, Germany, Greece, Hungary, India, Ireland,
Data Center Technology: Physical Infrastructure
Data Center Technology: Physical Infrastructure IT Trends Affecting New Technologies and Energy Efficiency Imperatives in the Data Center Hisham Elzahhar Regional Enterprise & System Manager, Schneider
Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency
A White Paper from the Experts in Business-Critical Continuity TM Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency Executive Summary Energy efficiency