Webinar: Precision Cooling in Data Centres and other applications 24 June 2014
|
|
- April Wheeler
- 8 years ago
- Views:
Transcription
1 Webinar: Precision Cooling in Data Centres and other applications 24 June 2014 Jeremy Towler - Senior Manager Energy & Smart Technologies David Garwood Researcher Air-conditioning solutions Helen Bedford Researcher IT Networks and Convergence Lone Hansen - Senior Manager - IT Networks and Convergence
2 Objectives To provide a definition of a Data centre, and of types of data centres To provide an overview of DC costs (new construction) Quantification of the data centre market (will vary depending on available data) Market estimation by key precision cooling product types used in data centres and other applications Forecast by precision cooling products , by data centres and other applications Product and market trends in data centre cooling General trends in the data centre market (outsourcing, ownership, modular DC, products vs services, etc.) 2 2
3 Project Scope Precision cooling Products 1. Computer room air conditioning (CRAC) 2. Air handling Units (AHU) 3. Evaporative cooling (Direct and indirect) 4. Rear door heat exchangers 5. In between row 6. Other Application In Data centres and computer rooms Non - DC cooling In telecommunications rooms, research labs in hospitals, pharmaceuticals etc. Data centre services (top line split) Mechanical: Cooling (80-90% of Mechanical cost) Construction cost 20 25% 20 25% Electrical: UPS 50 55% Standby generators and Switchgear LV distribution and PDU HV installation including transformers Security and fire detection Electrical monitoring systems and other power Fire detection 3 3
4 Scope - Reports and content Data centre definitions, clarifications and trends Data centre definition and types of data centres Quantification of data centres (if possible) An overview of DC cost in new construction General trends in the data centre market (outsourcing, ownership, modular DC, products vs services, etc.) Global Data centre cooling Market size by product type Market forecast by product type Market and product trends Precision cooling globally (in DC and non-dc environments) Market size by product type Market forecast by product type Market and product trends 4 4
5 Countries to be covered 1 st Division USA 35-40% of the DC global market 2 nd Division China UK Germany Each country accounts for 6-8% of the DC global market 3 rd Division Canada Australia, Brazil, India, Japan, Russia, France and Switzerland Each country accounts for 2-3% of the DC global market 5 5
6 Research approach - Countries to be covered USA China Brazil UK Germany India ~60% of the global DC Cooling market Canada Australia Japan France Russia An additional ~15% of the Global market North America Latin America Europe AsiaPac 6 6
7 Overview of cooling products used in Data Centres 7 7
8 Computer Room Air Conditioning Close control units are still the main solutions for cooling of data halls. (CRAC) They are cooled by either a dx condensing unit or by a chilled water loop. Non Ducted Upflow Upflow Downflow Downflow Non-ducted ducted supply underfloor supply underfloor The cost of CRAC units with fans, centralised ventilation/dehumidification system and separate humidifiers make them one of the most cost effective solutions for a new Data Centre facility Adding Variable Controls and EC Fans will provide the necessary option for energy efficiency All pictures courtesy of Uniflair 8 8
9 Rear Door Heat Exchangers (RDHE) Mainly used in areas where the server rack generating a lot of heat. They are normally cooled by chilled water. Some products are fan-assisted, others use a passive system, resulting in lower energy costs and maintenance. DX versions are available These work on refrigeration rather than water and use a condenser rather than chiller system. 9 9
10 In-Between Row Cooling In between row cooling, together with rear door heat exchangers, are known as closed coupled cooling. These units are used in areas of high density cooling requirements and are placed in between or beside existing IT racks Indirect expansion or chilled water models are available In Between row: Picture Hitachi Most units blow cold air sideways onto the adjoining IT rack. Others blow air directly into the aisle. The chilled water versions can provide up to 60kW of cooling
11 Direct and Indirect Evaporative cooling Direct evaporative cooling (open circuit) is used to lower the temperature of air by using latent heat of evaporation, changing liquid water to water vapour. Indirect evaporative cooling (closed circuit) uses outdoor air to reject heat, but the outdoor air never enters the space. In-direct evaporative cooling module: Source Excool In-direct evaporative cooling module (Source: Munters) 11 11
12 Direct and Indirect Evaporative cooling With the indirect solution there is no mixing of outdoor air with the inside. It removes heat from the data hall return air, rejecting it through an air to air heat exchanger to external ambient air. The main downside of evaporative systems is that they consume water (which can be an issue if supplies are scarce). Direct evaporative cooling module. Source: Eco cooling 12 12
13 Project deliverables 13 13
14 Deliverables Data centre definitions, clarifications and trends Types of data centres Data centre definition and types of data centres Quantification of data centres (if possible) An overview of DC costs in new construction Types of data centres, by size General trends in the data centre market (outsourcing, ownership, modular DC, products vs services, etc.) 14 14
15 Deliverables Example: Data Centre Services Costs Breakdown Uptime Institute Survey 2013 highlighted that the majority of costs worldwide fall in the region of $5 mil per 1mW or less, and underlined that larger sites are more inclined to spend more on the additional redundancy and efficiency measures coupled with more complex designs. UPS Standby generators Switchgear LV distribution PDU HV installations incl transformers Security Electrical Monitoring System Other power Fire Detection Cooling 80%-90% * Excluding IT Sources: CIBSE, SPONS 2013, Digital Realty, CBRE, Uptime Institute 15 0% 5% 10% 15% 20% 15
16 Modular is an emerging alternative model, but market is still conservative Modular DC Solutions have sparked interest among different groups of companies: from system integrators and systems manufacturers to colocation providers and dedicated niche modular DC manufacturers. 3 Types of Modular Data Centres: 1. Outdoor Containers 2. Indoor Modules (Rack/Row level or Modules) 3. Pre-fabricated Flexible Solutions Trends in the Market: Worldwide rates of planned installations stay at 2012 level, UK market is showing interest but uptake is slow. Estimated at 2-5% of the total market. While the technologies are evolving and some organisations are attracted by the flexibility of the modular data centre, 2013 saw a negative trend with declining interest in prefabricated designs and modules Reliability of modular solutions is seen as one of the most important factors and many end users would still prefer to wait and see to ensure that the costs are justified as they are comparable to standard Data Centre construction costs The general levels of confidence into the modular data centre market is still shaky with 61% being only somewhat confident The range of players providing solutions for this segment also stretches to system integrators and colocation providers themselves entering the market with the complete branded package 16 16
17 Deliverables - Global Data Centres cooling Quantitative Qualitative By application: DC and Non-DC Total Maket sizes for 2013 & 2014 with forecasts to 2017 Market sizes by product type (value) Market sizes by product type (avg. price and volume) Market sizes by size/capacity (kw) Market characteristics Price developments Routes to market Product trends Market trends Market shares by product type 17 17
18 Product Scope: Precision cooling - Market Size Segments Total Market 2013 Volume and Value (US$) and 5 year forecast Close coupled: - Rear door heat exchanger - In between rows - Overhead terminals Close control AHU Evaporative cooling Total Market 2013 by product segment Volume and Value (US$) and 5 year forecast DX condensers Chillers Other Heat rejection Total Market 2013 by segment and by size (size segments to be defined at kickoff). Volume and Value (US$) Size 1 KW Size 2 KW Size 3 KW Size 1 KW Size 2 KW Size 3 KW Size 1 KW Size 2 KW Size 3 KW Size 1 KW Size 2 KW Size 3 KW Total Market 2013 by application in % of value Telecommunications, Labs etc. Data Centres & Computer rooms 18 18
19 Market value Deliverables - Market size by product type The UK Data Centre cooling market is undergoing changes with indirect evaporative cooling taking share from CRAC. The market has been dominated for some considerable time by the top five close control companies namely Denco, Emerson, Stulz, Airedale and Uniflair. However Excool and Munters are taking greater share through selling indirect evaporative cooling. The total size of the data centre cooling market in 2014 will increase by 20% in value over 2013 Rear Door Heat Exchangers (RDHx) and in-between row will also take share from CRAC, but many systems are installed in conjunction with CRAC for high density cooling zones. RDHX are also being sold as a complete stand alone solution and are being cooled by hybrid dry coolers, as well as DX condensing units and chillers
20 Deliverables - Trends in Computer Room Air Conditioning The main trend in the market place is towards hot and cold aisle containment- mostly the latter as hot aisle containment with CRAC is expense. Developments in IT cooling equipment will always follow trends in server development. At present, the trend is towards cooling equipment with higher capacity units, as the servers are generating more heat. Going forward, the CRAC product is still fit for purpose and the market is witnessing a lot of retrofit applications. This is now starting to change with increased activity in the new build sector. The table below shows the market by type of cooling by volume. Chilled water will represent the greater share by value, as these will tend to be larger capacity units, typically between kW cooling capacity 20 20
21 Research methodology and timescale 21 21
22 Methodology Industry sources and public domain information Desk research will select relevant information from published sources In-house BSRIA market data BSRIA s market knowledge will be part of the analysis. BSRIA regularly (yearly or every two years) conducts syndicated research on AC, including top line market data on close controls / precision cooling Analysis Telephone interviews with key suppliers, consultants, industry experts, data centre design consultants and M & E contractors Face to Face interviews with key suppliers, consultants and M & E contractors 22 22
23 Methodology - Interviews planned by country Number of interviews (might vary according to location of HQ): US Canada Brazil China India Australia Japan UK Germany France Russia Total Suppliers F-F interviews Tel interviews M & contactors, contractors, consultants F-F interviews Tel interviews Total number of interviews Face to face interviews with key suppliers, consultants, M & E contractors in the key markets e.g. USA, China, UK, Germany and Brazil. Additional telephone interviews in the above countries. Telephone interviews with key suppliers, consultants, M & E contractors in the other research countries e.g. Canada, India, Australia, Japan, France and Russia. The above 11 countries account for approximately 75% of the DC cooling market
24 Timescale Start: June/July 2014 Desk research Interview phase Analysis Completion: November/December 2014 Report writing Deliverables: PowerPoint Report Excel tables For each of the three areas. Please note that the start time will depend how quickly the clients sign up 24 24
25 Project sponsorship 25 25
26 Benefits of Sponsorship The advantages of being an Early Bird 1. Receipt of the study for a 25% reduction on the published price 2. Receipt of the study at a fraction of the programme cost 3. The opportunity to help shape the structure and the scope of the study 4. Sponsors can choose to include colleagues in a final webinar presentation going over the primary results of the study, asking questions and learning from the collaborative discussions 5. Sponsors can share the complete report with their entire organization 6. The final report will be delivered as a set of Pdf files (in PowerPoint format) and an Excel workbook. 7. BSRIA will retain the copyright of the study and it undertakes not to sell reports for less than the original sponsorship price
27 Prices Early bird price (up to 31 st of July) 4, Data centre definitions, clarifications and trends 2. Global Data Centre Cooling 7, Data centre definitions, clarifications and trends 2. Global Data Centre Cooling 3. Global Precision cooling (Data Centre and non- Data Centre applications) 27 27
28 Prices Publication price (October 2014) 6, Data centre definitions, clarifications and trends 2. Global Data centre cooling 10, Data centre definitions, clarifications and trends 2. Global Data centre cooling 3. Global Precision cooling (DC and non-dc applications) 28 28
29 Why BSRIA? Have published several reports on Data centres: Technical services in DC, UK Sept DC cooling, UK. Oct Data centre cabling, US. End-users survey and trends (2008) Data centre cabling, UK. End-users survey and trends (2009) Global DC study (6 countries). End-users survey and trends (2011) Regular studies on the air conditioning market. The in-depth reports include information on close controls or precision cooling. BSRIA has: 50 + years of research and consultancy experience where we have identified and solved many problems for thousands of satisfied clients. We understand the Close Control market, having written many world-wide studies on this topic since % of the work we undertake each year is single client work, so our track record of being a safe pair of hands is known. We are experienced in questionnaire design and all forms of interview techniques and have undertaken numerous partner finding studies and provided due diligence in co-operation with our management consultancy arm. We have a unique blend of technical and marketing capability which means that we not only understand technical issues but also how products and services fit into the market place. There are a total of 160 staff at BSRIA so additional support can be tapped into as required. BSRIA s services are fully independent which enables us to provide outputs that offer an objective approach
30 BSRIA Contact Information Jeremy Towler BBA (GSBA Zurich). Betriebsoekonom dipl. oek. Senior Manager Energy and Smart Technologies Old Bracknell Lane West, Bracknell, Berkshire RG12 7AH D : +44 (0) F : +44 (0) M : +44 (0) E : jeremy.towler@bsria.co.uk W :
Technical Systems. Helen Bedford
Technical Systems in Data Centres Helen Bedford Technical Systems in Data Centres Overview Cooling IT and Peripheral Equipment Security: Access and Control Building Management System (BMS) Data Centre
More informationCURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers
CURBING THE COST OF DATA CENTER COOLING Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers OVERVIEW Compare Cooling Strategies in Free- Standing and In-Building
More informationElements of Energy Efficiency in Data Centre Cooling Architecture
Elements of Energy Efficiency in Data Centre Cooling Architecture Energy Efficient Data Center Cooling 1 STULZ Group of Companies Turnover 2006 Plastics Technology 400 Mio A/C Technology 200 Mio Total
More informationEXAMPLE OF A DATA CENTRE BUILD
EXAMPLE OF A DATA CENTRE BUILD BT Harmondsworth Data Centre Hall 2 Upgrade Temperature Control have been involved in providing specialist to data centres for over 20 years, starting from providing specialist
More informationMulti-client Technical Systems in Data Centres in the UK. By: Helen Bedford Quality Approved: Lone Hansen September 2013 Project: 57315
Multi-client Technical Systems in Data Centres in the UK By: Helen Bedford Quality Approved: Lone Hansen September 2013 Project: 57315 UK Market is the 2 nd Largest in the World. The Objective To describe
More informationUniversity of St Andrews. Energy Efficient Data Centre Cooling
Energy Efficient Data Centre Cooling St. Andrews and Elsewhere Richard Lumb Consultant Engineer Future-Tech Energy Efficient Data Centre Cooling There is no one single best cooling solution for all Data
More informationState of the Art Energy Efficient Data Centre Air Conditioning
- White Paper - State of the Art Energy Efficient Data Centre Air Conditioning - Dynamic Free Cooling - Release 2, April 2008 Contents ABSTRACT... 3 1. WHY DO I NEED AN ENERGY EFFICIENT COOLING SYSTEM...
More informationFree Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions
Free Cooling in Data Centers John Speck, RCDD, DCDC JFC Solutions Why this topic Many data center projects or retrofits do not have a comprehensive analyses of systems power consumption completed in the
More information7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America
7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer
More informationDATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER
DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER DATA CENTERS 2009 IT Emissions = Aviation Industry Emissions Nations Largest Commercial Consumers of Electric Power Greenpeace estimates
More informationCoolTeg Plus Chilled Water (CW) version: AC-TCW
version: 12-04-2013 CONTEG DATASHEET TARGETED COOLING CoolTeg Plus Chilled Water (CW) version: AC-TCW CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420
More informationIn Row Cooling Options for High Density IT Applications
In Row Cooling Options for High Density IT Applications By Ramzi Y. Namek, PE, LEED AP, BD+C; Director of Engineering 1 Users wishing to deploy high density IT racks have several In Row Cooling solutions
More informationBlade Server & Data Room Cooling Specialists
SURVEY I DESIGN I MANUFACTURE I INSTALL I COMMISSION I SERVICE SERVERCOOL An Eaton-Williams Group Brand Blade Server & Data Room Cooling Specialists Manufactured in the UK SERVERCOOL Cooling IT Cooling
More information- White Paper - Data Centre Cooling. Best Practice
- White Paper - Data Centre Cooling Best Practice Release 2, April 2008 Contents INTRODUCTION... 3 1. AIR FLOW LEAKAGE... 3 2. PERFORATED TILES: NUMBER AND OPENING FACTOR... 4 3. PERFORATED TILES: WITH
More informationAnalysis of data centre cooling energy efficiency
Analysis of data centre cooling energy efficiency An analysis of the distribution of energy overheads in the data centre and the relationship between economiser hours and chiller efficiency Liam Newcombe
More informationIBM Portable Modular Data Center Overview for Critical Facilities Round Table
Brian Canney Global Services Executive, IBM GTS Site and Facilities Services April 2011 IBM Portable Modular Data Center Overview for Critical Facilities Round Table 2009 IBM Corporation Key messages Containers
More informationI-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 4, Lancaster University, 2 nd July 2014
I-STUTE Project - WP2.3 Data Centre Cooling Project Review Meeting 4, Lancaster University, 2 nd July 2014 Background Data centres estimated to use 2-3% of total electricity consumption in the UK and generate
More informationS c h n e i d e r E l e c t r i c BUSINESS IMPACT. Jack Hack Enterprise System Engineer 19 November 2015
S c h n e i d e r E l e c t r i c BUSINESS IMPACT Datacenter means business - create the bridge between IT en Facilities. Jack Hack Enterprise System Engineer 19 November 2015 1 Your ability to compete
More informationI-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 8, Loughborough University, 29 th June 2015
I-STUTE Project - WP2.3 Data Centre Cooling Project Review Meeting 8, Loughborough University, 29 th June 2015 Topics to be considered 1. Progress on project tasks 2. Development of data centre test facility
More informationData Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling
Data Center Design Guide featuring Water-Side Economizer Solutions with Dynamic Economizer Cooling Presenter: Jason Koo, P.Eng Sr. Field Applications Engineer STULZ Air Technology Systems jkoo@stulz ats.com
More informationWhite Paper Rack climate control in data centres
White Paper Rack climate control in data centres Contents Contents...2 List of illustrations... 3 Executive summary...4 Introduction...5 Objectives and requirements...6 Room climate control with the CRAC
More informationPaul Oliver Sales Director. Paul Oliver, Airedale Tom Absalom, JCA
Paul Oliver Sales Director Paul Oliver, Airedale Tom Absalom, JCA Airedale an overview 25,000m 2 UK premier test centre 450 staff Global distribution A Modine company Modine centre of excellence Airedale
More informationThe Pros and Cons of Modular Systems
The Pros and Cons of Modular Systems Kevin Brown, Vice President Global Data Center Offer Schneider Electric Schneider Electric 1 Foundational BUSINESS OVERVIEW Rev 2 Desired characteristics of pre-fabricated
More informationClimate solutions. evaporative cooling, adiabatic humidification and programmable controllers. energy saving solutions for data centers. carel.
Climate solutions evaporative cooling, adiabatic humidification and programmable controllers energy saving solutions for data centers carel.com Data center air-conditioning Data center air-conditioning
More informationNational Grid Your Partner in Energy Solutions
National Grid Your Partner in Energy Solutions National Grid Webinar: Enhancing Reliability, Capacity and Capital Expenditure through Data Center Efficiency April 8, 2014 Presented by: Fran Boucher National
More informationLiquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.
Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED. Presentation Goals & Outline Power Density Where we have been- where we are now - where we are going Limitations of Air Cooling
More informationData Center Cooling Systems Market (2013-2018): Liquid. Cooling Types (In-Row, Overhead, Rear Door, In-Rack); Air
Data Center Cooling Systems Market (2013-2018): Liquid Cooling Types (In-Row, Overhead, Rear Door, In-Rack); Air Cooling Solutions and Analysis by Data Center Sizes Data centers consume huge amounts of
More informationLegacy Data Centres Upgrading the cooling capabilities What are the options?
Legacy Data Centres Upgrading the cooling capabilities What are the options? Presentation Structure What is a Legacy Data Centre? What is CRAC cooling? ASHRAE Standards Overview Available Cooling Systems
More informationEuropean Code of Conduct for Data Centre. Presentation of the Awards 2014
European Code of Conduct for Data Centre Presentation of the Awards 2014 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport 1 The Code of Conduct for Data Centre Results European
More informationCANNON T4 MINI / MICRO DATA CENTRE SYSTEMS
CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS Air / Water / DX Cooled Cabinet Solutions Mini Data Centre All in One Solution: Where there is a requirement for standalone computing and communications, or highly
More informationRaised Floor Data Centers Prepared for the Future
Raised Floor Data Centers Prepared for the Future Raised Floors Protect My Investment by Providing a Foundation for Current and Future Technologies. Creating the Future Proof Data Center Environment The
More informationManaging Cooling Capacity & Redundancy In Data Centers Today
Managing Cooling Capacity & Redundancy In Data Centers Today About AdaptivCOOL 15+ Years Thermal & Airflow Expertise Global Presence U.S., India, Japan, China Standards & Compliances: ISO 9001:2008 RoHS
More informationData Centre Testing and Commissioning
Data Centre Testing and Commissioning What is Testing and Commissioning? Commissioning provides a systematic and rigorous set of tests tailored to suit the specific design. It is a process designed to
More informationHVAC Infrastructure Retrofit Solutions
Kyoto Cooling Lunch & Learn David Belleville, APA LLC March 9, 2015 Owners choose APA solutions to: Rely on our 30+ years of delivering engineered solutions; HVAC Infrastructure Retrofit Solutions Insure
More informationEnergy Efficient Data Centre at Imperial College. M. Okan Kibaroglu IT Production Services Manager Imperial College London.
Energy Efficient Data Centre at Imperial College M. Okan Kibaroglu IT Production Services Manager Imperial College London 3 March 2009 Contents Recognising the Wider Issue Role of IT / Actions at Imperial
More informationAERMEC DATA CENTRE SOLUTIONS THE COMPLETE RANGE OF AERMEC SOLUTIONS FOR DATA CENTRES
AERMEC DATA CENTRE SOLUTIONS THE COMPLETE RANGE OF AERMEC SOLUTIONS FOR DATA GLOBAL DATA CENTRE IP TRAFFIC WILL TRIPLE WITHIN 5 YEARS Global data centre IP traffic has set a constant growth path, with
More informationThe Different Types of Air Conditioning Equipment for IT Environments
The Different Types of Air Conditioning Equipment for IT Environments By Tony Evans White Paper #59 Executive Summary Cooling equipment for an IT environment can be implemented in 10 basic configurations.
More informationBYRNE DIXON HAS BRIGHT IDEAS. Reducing data centre energy usage
BYRNE DIXON HAS BRIGHT IDEAS Reducing data centre energy usage 1.1 Introduction Agenda Data Centre Efficiency Data Centre Efficiency Byrne Dixon Background Data Centre Efficiency Theory Government Support
More informationGREEN FIELD DATA CENTER DESIGN WATER COOLING FOR MAXIMUM EFFICIENCY. Shlomo Novotny, Vice President and Chief Technology Officer, Vette Corp.
GREEN FIELD DATA CENTER DESIGN WATER COOLING FOR MAXIMUM EFFICIENCY Shlomo Novotny, Vice President and Chief Technology Officer, Vette Corp. Overview Data centers are an ever growing part of our economy.
More informationSite Preparation Management Co., Ltd. March 1st 2013 By Nara Nonnapha, ATD UPTIME
Site Preparation Management Co., Ltd. March 1st 2013 By Nara Nonnapha, ATD UPTIME 2 AGENDA SESSION -1 What is Data Center? SESSION -2 Equipment and Components SESSION -3 Standard in designing Data Center
More informationCapgemini UK Infrastructure Outsourcing
Together. Free your energies Capgemini UK Infrastructure Outsourcing Project Arthur Improved Data Centre Efficiency Paul Feeney Capgemini Tony Mills Spie Matthew Hall Project Arthur The Toltec data centre,
More informationInternational Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS
International Telecommunication Union ITU-T TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU Technical Paper (13 December 2013) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES
More informationModular Data Center Cooling. Ultra High Efficiency. Oasis Optimum DCIE
Modular Data Center Cooling Ultra High Efficiency Oasis Optimum DCIE Oasis Optimum Modular Cooling Compact, Economic, Greener, Ultra High Efficiency Munters Oasis Optimum DCIE data center cooling solution
More informationOptimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009
Optimum Climate Control For Datacenter - Case Study T. Prabu March 17 th 2009 Agenda 2 About EDEC (Emerson) Facility Data Center Details Design Considerations & Challenges Layout Design CFD Analysis Of
More informationAn Introduction to Cold Aisle Containment Systems in the Data Centre
An Introduction to Cold Aisle Containment Systems in the Data Centre White Paper October 2010 By Zac Potts MEng Mechanical Engineer Sudlows October 2010 An Introduction to Cold Aisle Containment Systems
More informationThe New Data Center Cooling Paradigm The Tiered Approach
Product Footprint - Heat Density Trends The New Data Center Cooling Paradigm The Tiered Approach Lennart Ståhl Amdahl, Cisco, Compaq, Cray, Dell, EMC, HP, IBM, Intel, Lucent, Motorola, Nokia, Nortel, Sun,
More informationSTULZ View On DataCenter Cooling
STULZ View On DataCenter Cooling Stulz Was Founded In Hamburg (Germany) In 1947 And Has 5 Production Sites And 14 Subsidiaries In 14 Countries. We Are Represented By Partners In Over 110 Countries. Stulz
More informationData Center Energy Profiler Questions Checklist
Data Center Energy Profiler Questions Checklist Step 1 Case Name Date Center Company State/Region County Floor Area Data Center Space Floor Area Non Data Center Space Floor Area Data Center Support Space
More informationCombining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency
A White Paper from the Experts in Business-Critical Continuity TM Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency Executive Summary Energy efficiency
More informationGuideline for Water and Energy Considerations During Federal Data Center Consolidations
Guideline for Water and Energy Considerations During Federal Data Center Consolidations Prepared for the U.S. Department of Energy Federal Energy Management Program By Lawrence Berkeley National Laboratory
More informationEnterprise Data Centres
Enterprise Data Centres 09/12/2014 MAR0064 Cannon Data Campus s Pre-Engineered, factory built modules and systems combine to produce a high performance, efficient, Data Centre Campus. s White Space, Mechanical
More informationSASO XXXX:2016. (Including the modifications approved in Saudi Council Board No. XXX/2016) LARGE CAPACITY AIR CONDITIONERS
SASO XXXX:2016 (Including the modifications approved in Saudi Council Board No. XXX/2016) LARGE CAPACITY AIR CONDITIONERS PERFORMANCE REQUIREMENTS AND METHODS OF TESTING 1 LARGE CAPACITY AIR CONDITIONERS
More informationAPC APPLICATION NOTE #112
#112 Best Practices for Deploying the InfraStruXure InRow SC By David Roden Abstract The InfraStruXure InRow SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets.
More informationVISIT 2010 Fujitsu Forum Europe 0
VISIT 2010 Fujitsu Forum Europe 0 Virtualization & Automation Room 13a Shaping tomorrow with you. Green Data Center Services Martin Provoost Director, Data Centers and Networks, Fujitsu UK & Ireland 14:00
More informationAnalysis of the Brazilian Data Center Power Supplies Market
Analysis of the Brazilian Data Center Power Supplies Market IT Infrastructure Outsourcing Services Compel New Trends for this Growing Market ND27-14 September 2013 Contents Section Slide Numbers Executive
More informationPresentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks
Presentation Outline Common Terms / Concepts HVAC Building Blocks Plant Level Building Blocks Description / Application Data Green opportunities Selection Criteria Air Distribution Building Blocks same
More informationNews in Data Center Cooling
News in Data Center Cooling Wednesday, 8th May 2013, 16:00h Benjamin Petschke, Director Export - Products Stulz GmbH News in Data Center Cooling Almost any News in Data Center Cooling is about increase
More informationData Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling
Data Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling Joshua Grimshaw Director of Engineering, Nova Corporation
More informationSolutions to Make Your Data Center Energy Effi cient
Common $en e: Solutions to Make Your Data Center Energy Effi cient Energy effi ciency is a life style. It s also common sense. In a data center, the name of the game is effi ciency and how many compute
More informationCOOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C
COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing
More informationCANNON T4 MODULAR DATA CENTRE HALLS
CANNON T4 MODULAR DATA CENTRE HALLS Halve up-front investment, use a Modular fit out approach Highly efficient, Low PUE, Scalable system with reduced Capex and Opex Turnkey solutions available complete,
More informationData Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity
Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise A White Paper from the Experts in Business-Critical Continuity Executive Summary Today s data centers are changing rapidly,
More informationFree Cooling for Data Centers
Free Cooling for Data Centers Release 1, September 2015 Contents 1. Abstract... 3 2. Introduction... 3 3. Data Center Temperatures and Free Cooling... 4 4. Direct Free Cooling... 4 5. Indirect Free Cooling...
More informationMinimising Data Centre Total Cost of Ownership Through Energy Efficiency Analysis
Minimising Data Centre Total Cost of Ownership Through Energy Efficiency Analysis Sophia Flucker CEng MIMechE Ing Dr Robert Tozer MSc MBA PhD CEng MCIBSE MASHRAE Operational Intelligence Ltd. info@dc-oi.com
More informationEuropean Code of Conduct for Data Centre. Presentation of the Awards 2016
European Code of Conduct for Data Centre Presentation of the Awards 2016 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport 1 The Code of Conduct for Data Centre Results European
More informationIT BUSINESS. Hal Grant, EVP IT. February 19, 2015
IT BUSINESS Hal Grant, EVP IT February 19, 2015 1 Disclaimer All forward-looking statements are Schneider Electric management s present expectations of future events and are subject to a number of factors
More informationCooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: www.cruptime.com Uptime Racks: www.uptimeracks.com
Cooling Small Server Rooms Can Be Inexpensive, Efficient and Easy - Jim Magallanes Computer Room Uptime: www.cruptime.com Uptime Racks: www.uptimeracks.com Server Rooms Description & Heat Problem Trends
More informationGreening Commercial Data Centres
Greening Commercial Data Centres Fresh air cooling giving a PUE of 1.2 in a colocation environment Greater efficiency and greater resilience Adjustable Overhead Supply allows variation in rack cooling
More informationTour of new eircom Data Centre Blanchardstown by Dervan Engineering Consultants 11 th March 2015
Tour of new eircom Data Centre Blanchardstown by Dervan Engineering Consultants 11 th March 2015 Presentation Outline Mechanical Overview Chillers and Pumps Pipework and Ancillaries In Row Cooling Units
More informationTypes of Prefabricated Modular Data Centers
Types of Prefabricated Modular Data Centers White Paper 165 Revision 0 by Wendy Torell Executive summary Data center systems or subsystems that are preassembled in a factory are often described with terms
More informationEuropean Code of Conduct for Data Centre. Presentation of the Awards 2013
European Code of Conduct for Data Centre Presentation of the Awards 2013 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport 1 The Code of Conduct for Data Centre Results Started
More informationHow High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions
Intel Intelligent Power Management Intel How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions Power and cooling savings through the use of Intel
More informationCIBSE ASHRAE Group. Data Centre Energy Efficiency: Who, What, Why, When, Where & How
CIBSE ASHRAE Group Data Centre Energy Efficiency: Who, What, Why, When, Where & How Presenters Don Beaty PE, FASHRAE Founder, President & Managing Director DLB Associates Consulting Engineers Paul Finch
More informationGUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY. Public Sector ICT Special Working Group
GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY Public Sector ICT Special Working Group SERVER ROOM ENERGY EFFICIENCY This guide is one of a suite of documents that aims to provide guidance on ICT energy efficiency.
More informationSTULZ Water-Side Economizer Solutions
STULZ Water-Side Economizer Solutions with STULZ Dynamic Economizer Cooling Optimized Cap-Ex and Minimized Op-Ex STULZ Data Center Design Guide Authors: Jason Derrick PE, David Joy Date: June 11, 2014
More informationTitle: Design of a Shared Tier III+ Data Center: A Case Study with Design Alternatives and Selection Criteria
Tier 3+ 1 Title: Design of a Shared Tier III+ Data Center: A Case Study with Design Alternatives and Selection Criteria Abstract: Schoolcraft College is constructing a High Availability (HA) Data Center
More informationDataCenter 2020: first results for energy-optimization at existing data centers
DataCenter : first results for energy-optimization at existing data centers July Powered by WHITE PAPER: DataCenter DataCenter : first results for energy-optimization at existing data centers Introduction
More informationStatement Of Work. Data Center Power and Cooling Assessment. Service. Professional Services. Table of Contents. 1.0 Executive Summary
Statement Of Work Professional Services Data Center Power and Cooling Assessment Data Center Power and Cooling Assessment Service 1.0 Executive Summary Table of Contents 1.0 Executive Summary 2.0 Features
More informationData Center Consolidation Trends & Solutions. Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert
Data Center Consolidation Trends & Solutions Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert Agenda Traditional Data Centers Drivers of a Changing Environment Alternate
More informationDataCenter 2020: hot aisle and cold aisle containment efficiencies reveal no significant differences
DataCenter 2020: hot aisle and cold aisle containment efficiencies reveal no significant differences November 2011 Powered by DataCenter 2020: hot aisle and cold aisle containment efficiencies reveal no
More informationEnergy-efficient & scalable data center infrastructure design
Seminar am 30. September 2010 in Wetzlar Nachhaltigkeit durch UPI (Unified Physical Infrastructure) Vortrag von Stefan Fammler: Energieeffiziente Strategien im Rechenzentrum Energy-efficient & scalable
More informationData Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore
Data Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore Introduction Agenda Introduction Overview of Data Centres DC Operational
More informationManaging Data Centre Heat Issues
Managing Data Centre Heat Issues Victor Banuelos Field Applications Engineer Chatsworth Products, Inc. 2010 Managing Data Centre Heat Issues Thermal trends in the data centre Hot Aisle / Cold Aisle design
More informationDefining Quality. Building Comfort. Precision. Air Conditioning
Defining Quality. Building Comfort. Precision Air Conditioning Today s technology rooms require precise, stable environments in order for sensitive electronics to operate optimally. Standard comfort air
More informationStanford University Server/Telecom Rooms Design Guide
Stanford University Server/Telecom Rooms Design Guide CONTENTS 1.0 How to Use this Guide...3 1.1 Document Organization...3 2.0 Summary Form and Sample Options Matrix...3 3.0 Options Matrix...7 4.0 Recommended
More informationData Center Technology: Physical Infrastructure
Data Center Technology: Physical Infrastructure IT Trends Affecting New Technologies and Energy Efficiency Imperatives in the Data Center Hisham Elzahhar Regional Enterprise & System Manager, Schneider
More informationData Center Solutions - The Containerized Evolution
Data Center Solutions - The Containerized Evolution Power IT Cooling 7 th Green Connected World Tsikogias Thanassis Data Centers Solutions Architect, IT Business Athens 2015 1 We are the global specialist
More informationImproving Data Center Energy Efficiency Through Environmental Optimization
Improving Data Center Energy Efficiency Through Environmental Optimization How Fine-Tuning Humidity, Airflows, and Temperature Dramatically Cuts Cooling Costs William Seeber Stephen Seeber Mid Atlantic
More informationColocation Selection Guide. Workspace Technology Ltd
Colocation Selection Guide Workspace Technology Ltd Technology House 5 Emmanuel Court Reddicroft Sutton Coldfield West Midlands B72 1TJ Tel 0121 354 4894 Fax 0121 354 6447 www.workspace-technology.com
More informationDealing with Thermal Issues in Data Center Universal Aisle Containment
Dealing with Thermal Issues in Data Center Universal Aisle Containment Daniele Tordin BICSI RCDD Technical System Engineer - Panduit Europe Daniele.Tordin@Panduit.com AGENDA Business Drivers Challenges
More informationContainment Solutions
Containment Solutions Improve cooling efficiency Separate hot and cold air streams Configured to meet density requirements Suitable for commercial and SCEC endorsed cabinets Available for retrofit to SRA
More informationIndependent analysis methods for Data Centers
Bilfinger HSG Facility Management GmbH Independent analysis methods for Data Centers Max Altmeyer / Marvin Köhler August 19 th, 2015 Agenda 1. Weak point analysis 2. Energy efficiency analysis 3. Combined
More informationCase Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia
Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia Prepared for the U.S. Department of Energy s Federal Energy Management Program
More informationHow To Run A Data Center Efficiently
A White Paper from the Experts in Business-Critical Continuity TM Data Center Cooling Assessments What They Can Do for You Executive Summary Managing data centers and IT facilities is becoming increasingly
More informationData Centre Cooling Technologies. Jon Pettitt, EMEA DataCenter Business Development Manager
Data Centre Cooling Technologies 1 Jon Pettitt, EMEA DataCenter Business Development Manager Munters Group Key facts 3.000 Employees 30 Countries Turnover of 470 M HQ in Sweden Global DC Support 25+ Data
More informationDirect Fresh Air Free Cooling of Data Centres
White Paper Introduction There have been many different cooling systems deployed in Data Centres in the past to maintain an acceptable environment for the equipment and for Data Centre operatives. The
More informationTHE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER
Your Complete Turnkey Server Room Air Condition UPS THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER AVAILABLE IN WATER AND GAS SYSTEM MODEL AIR-CONDITIONED CABINET EXCELLENT TEMPERATURE CONTROL FOR
More informationWhite Paper #10. Energy Efficiency in Computer Data Centers
s.doty 06-2015 White Paper #10 Energy Efficiency in Computer Data Centers Computer Data Centers use a lot of electricity in a small space, commonly ten times or more energy per SF compared to a regular
More informationHeating, ventilation and air conditioning equipment. A guide to equipment eligible for Enhanced Capital Allowances
Heating, ventilation and air conditioning equipment A guide to equipment eligible for Enhanced Capital Allowances 2 Contents Introduction 03 Background 03 Setting the scene 03 Benefits of purchasing ETL
More informationAPC by Schneider Electric
APC by Schneider Electric Energy Efficiency - The Green Power Solution James Taylor Business Development manager, UK APC by Schneider Electric The Efficient Enterprise Components Close Coupled Cooling
More information