1 Training & Didactic Systems Building Service Management System instabus EIB Catalog WA2E/07.01 Catalog WA2E/07.01

2 Table of Contents Page Introduction to instabus EIB 4 Configuration Proposals for instabus EIB 5 instabus EIB Compact Panel 9 instabus EIB Rack Version 10 instabus EIB Experimenter with Simulator 11 instabus EIB Experimental Panels 12 Teachware (Experiment Instructions, Specialized Books) 28 Software (ETS, ETS Demo, CBT Training Software) 30 Accessories 34 Notes 35 Our Range of Educational Services 36 3

3 Introduction In general Address assignment Adaptation to changed rooms The instabus EIB is a distributed data bus system for flexible service management in functional and residential buildings. Every storey, every room is individually supplied according to its requirements and conditions with the optimum electrical power for the respective time of day. This new technology revolutionizes electrical installation, is easy to comprehend and easy to implement. It saves time because planning is PC-based and much fewer leads must be laid during installation. As all components are optimally matched to one another, buildings with an instabus EIB installation consume considerably fewer resources and thus work more economically as traditional systems. What is more, the system can be quickly and easily adapted when the layout of the room changes by simply reassigning devices and components. Every bus station is provided with a teaching button with an LED at its coupler. When this button is pressed, the physical address sent by the PC is applied and acknowledged. Functional interaction is reached by allocating the group address. This address is sent by the sensor together with the telegram and is received by all bus couplers with the same group address. The time load on the bus line is very low here. With event-controlled transmission a signal is only sent when a sensor is actuated, so the bus line is used only for a short time. It is especially relevant for functional buildings that a displacement of partition walls, which is often necessary there for organizational reasons, does not require the removal or a new laying of leads. By means of a PC, the sensors and actuators can be assigned new group addresses that correspond to the new room layout, e.g. relations between light switches and lamps, from anywhere in the bus network. How does the instabus EIB work? All switches, pushbuttons and controls (sensors) are connected to the bus line by bus couplers. The bus line is a twowire MSR lead that runs through the whole building. If a pushbutton is actuated for example, a command telegram with a specific address goes on the bus line. The addressed actuators (relays, contactors, binary outputs, etc.) that are also connected to the bus line via their bus couplers receive the commands, but only those actuators or that actuator group will be activated which have been specified in the telegram address. So it is a prerequisite that all sensors and actuators obtain a physical address. Thus they can receive all further inputs like group addresses and parameters and can also be queried specifically, e.g. in the line of diagnostics during maintenance. WUEKRO experimenters After these words of introduction on building service management systems you will find experimenters and training units for the training and education on the instabus EIB on the following pages. 4

4 Configuration Proposals for instabus EIB Hands-on training I Starting package (basic configuration) 1 line power supply unit with RS 232 interface (type with 640 ma) 1 instabus EIB pushbutton, 2-fold 1 instabus EIB binary output, 2-fold 1 experimental panel with three lamp sockets W4010-1A W4010-2M W4010-3B W3228-4C The basic configuration can be expanded as desired by the following supplementary packages: Supplementary package 1 for further lamp circuits and brightness control of incandescent lamps 1 experimental panel with three lamp sockets 1 instabus EIB binary output, 2-fold 1 instabus EIB pushbutton, 4-fold 1 instabus EIB switching/dimming actuator for lamps W3228-4C W4010-3B W4010-2N W4010-3E Supplementary package 2 for Venetian blind control, 230 V 1 instabus EIB pushbutton, 2-fold 1 instabus EIB Venetian blind switch 1 experimental panel Venetian Blind, 230 V W4010-2M W4020-2J W4020-4C Supplementary package 3 for integrating conventional pushbuttons and specifying environmental values 1 instabus EIB pushbutton interface, 4-fold W4010-3K Supplementary package 4 for infrared remote control 1 instabus EIB IR receiver and decoder and a 2- fold wall-mounted transmitter 1 instabus EIB IR hand-held transmitter with channels W4010-3D W4010-5D Supplementary package 5 for the brightness control of fluorescent lamps 1 instabus EIB switching/dimming actuator with electronic ballast and fluorescent lamp 1 instabus EIB pushbutton, 4-fold W4010-3J W4010-2N 5

5 instabus EIB Compact Panel instabus EIB Compact Panel The instabus EIB compact panel is a space-saving and especially costeffective variant for starting with building services management systems. Especially the extremely short setting-up time has to be mentioned as an advantage. The compact panel can be used as an experimenter console or as an insert for the DIN A4 experimental racks. It consists of the following components: 1 line power supply unit (type with 640 ma) including reactor 1 RS 232 interface 1 binary input, 4-fold 1 binary output, 4-fold 1 scenic module Room lighting simulation consisting of 4 incandescent lamps and pluggable partition walls for a fast change of the room layout. All connections brought out to 4-mm safety lab sockets. Included are: 1 mains connecting lead 4 incandescent lamps 1 connecting lead PC - RS fold pushbutton with separate bus coupler 1 top-hat rail with integrated data bus In order to facilitate the connection of further modules it is possible to connect these via a Phoenix plug connection. Order-No. W4006 2R 9

6 instabus EIB Rack Version instabus EIB Experimental Rack In the left part of the unit 2 top-hat rails are mounted behind a transparent plastic cover. Into these top-hat rails instabus EIB data busses are glued. The following instabus EIB components have been snapped onto the first rail: 1 line power supply unit 1 reactor 1 binary output, 2-fold 1 binary output, 4-fold 2 connectors On the second top-hat rail 9 additional modular spacings can be equipped as desired. By the connectors, the bus is wired to 2-mm sockets and is transferred from there via plug-in connectors to all bus stations on the control panels. By using 2-mm sockets as an open interface further external bus stations may be connected easily. The following instabus EIB components are built into the control panels: 1 RS 232 interface 1 pushbutton, 2-fold 1 pushbutton, 4-fold The contacts of the binary outputs are wired to 4-mm safety lab sockets. Furthermore, 2 panels with 3 lamps each have been incorporated. Owing to the unchanging grid the individual panels are easily interchangeable. By a sideways attached mains plug with fine wire fuse and switch, the mains voltage is led internally to safety lab sockets. These sockets are designated L1 or N and PE. A glow lamp indicates the socket for L1. Included are: 1 mains connecting lead 1 short description 6 glow lamps, 230 V 1 connecting lead PC RS 232 Order-No. W4006 1A 10

7 instabus EIB Experimenter with Simulator instabus EIB Experimenter The instabus EIB experimenter is integrated in a sturdy case with a powdered look in anthracite. The main parts of the case are black ABS plates with two locks. The lid can be detached and is fitted with a carrying handle. The following instabus EIB components are integrated in the case bottom: 1 power supply unit (type with 640 ma) 1 RS 232 interface 2 binary output, 2-fold 1 binary input, 4-fold 2 bus coupler 1 time switch, dual-channel 1 twilight detector 1 switching/dimming actuator 1 Venetian blind switch By connectors the bus is wired to all bus stations. By using 2-mm sockets as an open bus interface further external bus stations may be connected easily. Into the control panel the following elements have been incorporated: 1 pushbutton, 1-fold 1 pushbutton, 2-fold 1 pushbutton, 4-fold 1 temperature controller 1 display unit 5 bus coupler 1 motion detector The detachable lid of the ready-touse instabus EIB experimenter houses two simulation modules for learning the basic possibilities of the building services management system by way of experiments. Room lighting simulation On the simulation panel a storey of a building with several rooms including corridor and staircase is represented. The partition walls are pluggable permitting the simulation of changes in the room in an easy manner. All 8 incandescent lamps (E14) can be connected to the respective actuator using safety lab sockets. To allow a better overview, N and PE are already wired internally. Venetian blind simulation with LED The Venetian blind simulation shows the position of the blind by an LED strip indicator and the blind strip position by single LEDs. The contacts of the binary outputs are wired to 4-mm safety lab sockets. By a sideways attached mains plug with fine wire fuse and switch, the mains voltage is led internally to safety lab sockets. Included are: 1 mains connecting lead 8 glow lamps, 230 V 1 connecting lead PC - RS 232 Dimensions of the case (W x H x D): 520 x 375 x 175 mm Weight approx.: 7 kg Order-No. W4006-0C 11

8 instabus EIB Experimental Panels Experimenter panels in general: The experimental panels are made from plastic. The color is white similar to RAL They are 297 mm high (DIN A4) and about 5 mm thick. The width is 130 mm or has been expanded by integer multiples of 65 mm. On the back the experimental panels have hoods out of transparent plastic. The devices and components are built into the panels or mounted on the back. The transfer of the bus signals is implemented by female 2-mm connectors. All terminals for the mains voltage are wired to 4-mm safety lab sockets. The simulation panels are supplied with voltage via the bus. The mimic diagrams, device symbols and labels are permanently attached to the panel fronts according to the prevailing standards. 12

9 Teachware Experiment instructions instabus EIB V051 Order-No. W3005-1B Detailed experiment instructions with exercises, solutions, descriptions of the software parameter settings and wiring diagrams. Excerpt from experiment instructions instabus EIB W3005-1B 28

10 Software EIB Tool Software ETS2.0 EIB Software ETS2.0 for configuring, commissioning, service and diagnosis of the instabus EIB. Minimum hardware requirements: Software: PC/AT DX, 66 MHz Main memory: 8 MB Hard disk with at least 40 MB free disk space Diskette drive 3.5" 1.44 MB VGA graphics card 14" color monitor Mouse In addition to the mouse port: one free serial port for RS 232 connection Printer or plotter recommended MS DOS 5.0 and MS Windows 3.1 or Windows 95 Vendor product databases for ETS2 Order-No. W4000-3A 30

11 Accessories Connecting leads of 0.5 mm 2 with 2-mm plugs (bus line) Length/color 7.5 cm black 7.5 cm red 30 cm black 30 cm red 60 cm black 60 cm red 100 cm black 100 cm red Order-No. W3903-1E W3903-1F W3903-3E W3903-3F W3903-8E W3903-8F W3903-5E W3903-5F Connecting leads of 2.5 mm 2 with 4-mm safety lab plugs Length/color 25 cm black 25 cm blue 50 cm black 50 cm blue 50 cm green/yellow 100 cm black 100 cm blue 100 cm green/yellow 150 cm black 150 cm blue Order-No. W3907-1E W3907-1G W3907-2E W3907-2G W3907-2H W3907-3E W3907-3G W3907-3H W3907-4E W3907-4G 34

12 Training & Didactic Systems Building Service Management System Powernet EIB Catalog WA2E/07.02 Catalog WA2E/07.02

13 Table of Contents Page Introduction to Powernet EIB 4 Configuration Proposal for Powernet EIB 5 Powernet EIB Experimental Panels 6 Accessories 11 Our Range of Educational Services 12 3

14 Introduction to Powernet EIB In general Up to now one has always assumed that apart from the power line a bus line is necessary, too, for transmitting information. That conception had a lot of advantages. It was no longer necessary to lay an immeasurable number of control leads, flexibility was increased and with a separate bus and power line susceptibility to interference was reduced to a minimum. In residential building and for existing facilities it is often desirable, how ever, to install EIB devices without having to lay new leads. This is possible with the Powernet EIB. It is no longer necessary to lay a separate bus line. Topology The topology is different from the conventional EIB topology. As all Powernet EIB devices are connected via the 230-V installation network with balanced link access, the typical distribution by lines and area couplers does not apply. In order to maintain a structural overview in the case of extensive sytems, a logical Data transmission takes place via the available 230-V installation network. Only a neutral and an outside conductor must be present in the branching box. The basic idea was the network bus X-10, which has been known for years. The corresponding technology has been changed fundamentally for the Powernet EIB, however, so that the only thing in common between the network bus X-10 and Powernet EIB is the transmission of control signals via the existing 230/400-V network. For example, a new transmission procedure called SFSK (Spread Frequency Shift Keying) is used. arrangement with lines and areas is recommendable here too though. Apart from the topological limits (4096 devices in one configuration area), the following physical limitations additionally apply in practice: This new transmission procedure stands out due to its high reliability for all network conditions. The remarkable thing about it is that the signals are transmitted via two separate frequencies. By a pattern comparison and an intelligent correction procedure a signal received can be corrected even in the event of trouble. A faultless telegram transmission is confirmed by a message from the receiver to the transmitter. Thus the transmission process is complete. If a transmitter does not receive a response, it repeats the transmission. The transfer rate is 1200 bits/s, a complete transmission lasts approx. 130 ms. - no operation beyond a transformer station, - no operation in networks with different network parameters or tolerances (e.g. 110 V/60 Hz), - no operation in networks with devices that have no proper interference suppression. Devices The devices of the Powernet EIB system have a similar design as the conventional EIB devices and are provided with the standard applications. They are programmed and operated with the EIB Tool Software from version 2.1 up. The scope of application is analogous to the fields where the EIB is used: Power management Demand-specific lighting Venetian blind control Signaling functions Single-room heating control and analog value transmission So, Powernet EIB is a supplementary technology for the EIB suitable for buildings and facilities where a laying of bus cables is not desired or not possible. The Powernet EIB facilitates EIB installation in residential building and a retrofitting of existing buildings with EIB. WUEKRO experimental panels The electrical engineer/electrician is more and more confronted with the subject Powernet EIB in his daily work. Comprehensive training or education is the foundation for later competitiveness. The experimental panels developed by WUEKRO can be used as supplements to the instabus EIB experimental panels. Both bus technologies can be connected using a media coupler. It is also possible, however, to set up and parameterize independent Powernet EIB systems. 4

15 Configuration Proposal for Powernet EIB Starting package (Basic configuration) Supplementary items 1 x Power supply panel (if the mains voltage is not picked off at the table) 1 x band-stop filter 1 x RS 232 interface 1 x pushbutton, 2-fold 1 x binary output, 4-fold 1 x storey lighting Annotation: W4020-1K W4030-3T W4030-1R W4030-2M W4030-3C W4020-1H 1 x pushbutton, 1-fold 1 x pushbutton, 4-fold 1 x pushbutton (conventional installation) 1 x binary output, 2-fold - binary input, 2-fold 1 x liquid crystal display (LCD) 1 x switching/dimming actuator 1 x wind sensor W4030-2L W4030-2N W3217-4B W4030-3S W4030-3M W4030-3J W4030-3U When installing a Powernet system usually three bandstop filters and one phase coupler are used (see circuit diagram on title page). In order to demonstrate the functioning and programming of the Powernet EIB it is sufficient to connect one phase. The experimental panel Phase Coupler is available upon request. 5

16 Powernet EIB Experimental Panels Experimenter panels in general: The experimental panels are made of plastic, the color is white similar to RAL 9002.They are 297 mm high (DIN A4) and about 5 mm thick. The width is 130 mm or has been expanded by integer multiples of 65 mm. On the back the experimental panels have hoods out of transparent plastic. The devices and components are built into the panels or mounted on the back. All terminals for the mains voltage are wired to 4-mm safety lab sockets. The simulation panels are supplied with voltage via the bus. The mimic diagrams, device symbols and labels are permanently attached to the panel fronts according to the prevailing standards. 6

17 Accessories Connecting leads of 2.5 mm 2 with 4-mm plugs Length/color 25 cm black 25 cm blue 50 cm black 50 cm blue 50 cm green/yellow 100 cm black 100 cm blue 100 cm green/yellow 150 cm black 150 cm blue Order no. W3907-1E W3907-1G W3907-2E W3907-2G W3907-2H W3907-3E W3907-3G W3907-3H W3907-4E W3907-4G Like the instabus EIB, the Powernet EIB is programmed using the EIB Tool Software ETS2. For further information on this software refer to our catalog section WA1E/07.01 (instabus EIB). 11

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

How To Use A Power Supply On A Powerline 2.2 (Ai)

How To Use A Power Supply On A Powerline 2.2 (Ai) KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang

More information

Transmitter Actuator 230V wave UP 560. Operation

Transmitter Actuator 230V wave UP 560. Operation Transmitter ctuator 230V wave UP 560 5WG3 560-201 Product- and pplication Description Diagram The transmitter actuator 230V wave UP 560 (Diagram ) is a flush-mounted device with radio communication for

More information

Light scene push button 8gang comfort flush-mounted 751688xx

Light scene push button 8gang comfort flush-mounted 751688xx 751688xx Documentation Product name: Light scene push button 8gang comfort Design: flush-mounting type (Up) ETS search path: Push button / Push button general / Light scene push button 8gang comfort Functional

More information

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111 , GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,

More information

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION The SST Model 5010 Two Channel Smoke/Fire Detection Module provides two independent detection input channels for the NOVA-5000

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

ELABOTrainingsSysteme. Aus- und Weiterbildung GmbH. Home and Building Control KNX / EIB. www.elabo-ts.com

ELABOTrainingsSysteme. Aus- und Weiterbildung GmbH. Home and Building Control KNX / EIB. www.elabo-ts.com Aus- und Weiterbildung GmbH Home and Building Control KNX / EIB www.elabo-ts.com Design and commissioning of KNX/EIB systems www.elabo-ts.com Hardware page 2-5 Software page 6-9 Projects page 10-15 LOGO!

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

Radio sensor powered by a mini solar cell the EnOcean STM 110 now functions with even less light

Radio sensor powered by a mini solar cell the EnOcean STM 110 now functions with even less light Radio sensor powered by a mini solar cell the EnOcean STM 110 now functions with even less light In this issue, we would like to present the EnOcean radio sensor module STM 110 in more detail. The module

More information

Push button 3gang standard flush-mounted 751633xx

Push button 3gang standard flush-mounted 751633xx Documentation Product name: Push button 3gang standard Design: device (up) ETS search path: Push button / Push button 3gang / Push button 3gang standard Functional description: The push button 3gang standard

More information

KNX Powerline PL 110. KNX Association

KNX Powerline PL 110. KNX Association KNX Powerline PL 110 Table of Contents 1 Introduction...3 2 Standardisation...3 3 Transmission Process...4 3.1 Phase Coupling...5 3.2 Telegram Transmission...6 3.2.1 Training Sequence...6 3.2.2 Preamble

More information

Inwall 4 Input / 4 Output Module

Inwall 4 Input / 4 Output Module Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...

More information

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information. Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an

More information

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted 7566359x, 7566459x, 7566559x

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted 7566359x, 7566459x, 7566559x B.IQ push button 3-5gang with room Product name: Design: ETS search path: B.IQ push button 3-, 4-, 5gang with room thermostat and display V2 Flush-mounted Push button / B.IQ / B.IQ push button xgang with

More information

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.

More information

Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted 756627xx, 756637xx, 756657xx

Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted 756627xx, 756637xx, 756657xx 756627xx, 756637xx, 756657xx Documentation Product name: Push button 2-, 3-, 5- gang RTR + display Design: UP (flush-mounting type) ETS search path: Push button / Push button xgang / Push button xgang

More information

Alliance System Ordering Guide

Alliance System Ordering Guide Alliance System Ordering Guide Multiple Technologies Versatile Hardware Powerful Software One family of parts and accessories Version 12-Nov-03 Alliance System Ordering Guide Table of Contents Controllers

More information

Instruction Manual Service Program ULTRA-PROG-IR

Instruction Manual Service Program ULTRA-PROG-IR Instruction Manual Service Program ULTRA-PROG-IR Parameterizing Software for Ultrasonic Sensors with Infrared Interface Contents 1 Installation of the Software ULTRA-PROG-IR... 4 1.1 System Requirements...

More information

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS FRANCE Head office USA 4 Rue du Bois Chêne le loup Parc d Activité de Brabois 54 500 VANDOEUVRE LES NANCY (33) 0383442413, Fax (33) 0383443797

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB , GH Q631 0076 R0111 2CDC 071 240 F0003 The Shutter Actuator Standard is used to control a maximum of four independent 230 VAC drives for positioning shutters, blinds, awnings and other hangings as well

More information

8 Channel Status Input Panel model SIP-8

8 Channel Status Input Panel model SIP-8 Description The Sine Systems model SIP-8 Status Input Panel is to be used with the RFC-1/B Remote Facilities Controller. It consists of a long PC board mounted on a 1.75 inch (1U) rack panel. The SIP-8

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421 VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421 TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS... 1 2-1 General Specifications...1 2-2 Electrical Specifications... 2 3. FRONT PANEL DESCRIPTION... 4 3-1

More information

SVC400P/SVC800P. 4/8 Camera Live Tracking Vehicle DVR Installation Manual. Version 1.0

SVC400P/SVC800P. 4/8 Camera Live Tracking Vehicle DVR Installation Manual. Version 1.0 SVC400P/SVC800P 4/8 Camera Live Tracking Vehicle DVR Installation Manual Version 1.0 1. MAIN FEATURES... 2 2. PRODUCT OVERVIEW... 2 3. DIMENSIONS... 4 4. PACKAGE CONTENTS... 5 5. MOUNTING AND ENVORNMENTAL

More information

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide Draper Low Voltage, Remote Control, Serial and Network Wiring Guide Copyright 2007 Draper Inc. Form LV-RC-Serial-Network_Wiring07 Print ed in U.S.A. Draper Low Voltage, Remote Control, Serial and Network

More information

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards. 56 / Accessories for inverters Accessories for inverters / Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards. FRONIUS STRING

More information

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute

More information

KNX Interface. User Manual PM00A00IRI

KNX Interface. User Manual PM00A00IRI KNX Interface User Manual PM00A00IRI 1/9 1. Index 1. Index...2 2. Preface... 3 2.1. Overview... 3 2.2. System description... 3 2.3. Application programs... 3 2.4. Documentation... 3 3. Mechanical reference...

More information

RRV934. Multi-controller. Synco living

RRV934. Multi-controller. Synco living s 2 709 Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes SI-COLO Series SI-COLO2-LWL-HAMP-COL4 - Big measuring range: typ. 25 mm... 40 mm (with optical fiber and attachment optics KL-14 or KL-17) - Large assortment of optical fibers available (reflected or transmitted

More information

ISpac isolators. the perfect system

ISpac isolators. the perfect system ISpac isolators the perfect system 2 safe isolation Handling flammable and potentially explosive substances is part and parcel of everyday operations in many branches of industry. However, it is not possible

More information

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS FLEET MANAGEMENT & CAR SECURITY SYSTEM FOR PROVIDERS AND CUSTOMERS The Tracker Server Communication Program for data collection The Tracker Client Map Program intended for dispatching desks The GSM/GPRS

More information

ABB i-bus EIB / KNX Switch Actuator Modules for the Room Controller SA/M 2.6.1 ES/M 2.230.1, ES/M 2.24.1

ABB i-bus EIB / KNX Switch Actuator Modules for the Room Controller SA/M 2.6.1 ES/M 2.230.1, ES/M 2.24.1 Product Manual ABB i-bus EIB / KNX Switch Actuator Modules for the Room Controller SA/M 2.6.1 ES/M 2.230.1, ES/M 2.24.1 Intelligent Installation Systems This manual describes the function of the Switch

More information

Photovoltaic Solar Energy Unit EESFB

Photovoltaic Solar Energy Unit EESFB Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality

More information

Application/Connection Examples

Application/Connection Examples This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.

More information

Highly flexible the right KNX/DALI gateway for every requirement

Highly flexible the right KNX/DALI gateway for every requirement The worldwide standard for home and building control Highly flexible the right / gateway for every requirement Integrating lighting control into building control safely, efficiently and comfortably with

More information

ABB RTU560A Series CMU & Modules

ABB RTU560A Series CMU & Modules ABB RTU560A Series CMU & Modules 1KGT 150 648 V1.02 March 4, 2012 Slide 1 Contents RTU560A rack solutions March 4, 2012 Slide 2 560CSR01 Available for wall mounting and swing frame Supports redundant power

More information

overview DyNet over RS485

overview DyNet over RS485 technical guide systems integration overview Integration between various control systems within projects, reduce end-users need to have multiple interactions to perform what seems like one task such as

More information

Series Six Plus Programmable Controller

Series Six Plus Programmable Controller Series Six Plus Programmable Controller Gl?K-0147B June 1989 Central Processor Unit 8-Slot Rack 1l-Slot Rack General Description The Central Processor Unit (CPU) for the Series Six Plus Programmable Logic

More information

40.3. Control Relays and Timers

40.3. Control Relays and Timers .3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories

More information

Busch-Watchdog Presence EIB Type: 6131-74-102-500

Busch-Watchdog Presence EIB Type: 6131-74-102-500 Type: 6131-74-102-500 Contents Technical data 2-2 Application programs (List) 2-3 Circuit diagrams 2-3 in combination with Bus coupler FM (6120-102): Switch Value Cyclic Monitoring /3 2-4 Switch Value

More information

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2 Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male

More information

SENTRON Switching and Protection Devices Air Circuit Breakers

SENTRON Switching and Protection Devices Air Circuit Breakers Siemens AG 9 SENTRON Switching and rotection Devices Air Circuit reakers 5 5/ Introduction 3WL Air Circuit reakers 3WL Air Circuit reakers/ Non-Automatic Air Circuit reakers up to 63 A (AC) 5/6 General

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

MANUAL PC1000R INFO@APART-AUDIO.COM

MANUAL PC1000R INFO@APART-AUDIO.COM MANUAL PC1000R INFO@APART-AUDIO.COM Features The APart PC1000R is a professional multisource CD/USB/SD card music player, equipped with balanced and unbalanced analog outputs, coaxial and optical digital

More information

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion

More information

ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1

ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1 Product manual ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1 Intelligent Installation Systems This manual describes the function of the DALI-Gateway DG/S 8.1 with the application program Dim Slave Lightscenes

More information

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network IPThermo206G Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network IPThermo 206G is the central data handling terminal of the IPThermo Pro measurement network. This

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

46120-F0 Solar Energy Training System

46120-F0 Solar Energy Training System 46120-F0 Solar Energy Training System LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 06/2016 Table of Contents General Description 2 List of Equipment 2 List of Manuals 3 Table of Contents of

More information

Measuring, Controlling and Regulating with labworldsoft

Measuring, Controlling and Regulating with labworldsoft Kai-Oliver Linde IKA-Werke Staufen Neumagenstraße 27 79219 Staufen Measuring, Controlling and Regulating with labworldsoft Rapid and easy networking of lab devices from different manufacturers The user

More information

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer

More information

NGSS Data Consolidator (DC)

NGSS Data Consolidator (DC) NGSS Data Consolidator (DC) The Data Consolidator (DC) facilitates system configuration, monitors network status, and supervises long-term data storage and remote data transmission. The DC consists of

More information

SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines PART 1 -- GENERAL 1.1 WORK OF THIS SECTION SECTION 16720 - City of San Diego, CWP Guidelines A. The WORK of this Section includes providing manual and automatic fire alarm and smoke detection systems meeting

More information

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1 Product Manual ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1 Intelligent Installation Systems This manual describes the function of the EIB monitoring module EUB/S 1.1 with the Application program

More information

EDI Distributor Control Interface Wiring and Setup Instructions

EDI Distributor Control Interface Wiring and Setup Instructions Universal I/O EDI Distributor Control Interface Wiring and Setup Instructions EDI UNIVERSAL I/O INTERFACE MODULE The only interface needed for EDI-V5 controls Network compatible with all older EDI controls

More information

Inwall Room Temperature Unit

Inwall Room Temperature Unit Inwall Room Temperature Unit TM11B01KNX TM11B11KNX TM11B21KNX Product Handbook Product: Inwall Room Temperature Unit Order Code: TM11B01KNX TM11B11KNX TM11B21KNX Application Program ETS: TM11B_1KNX Inwall

More information

ABB i-bus EIB Logic Module LM/S 1.1

ABB i-bus EIB Logic Module LM/S 1.1 Product Manual ABB i-bus EIB Logic Module LM/S 1.1 Intelligent Installation System Contents page 1 General... 3 1.1 About this manual... 3 1.2 Product and functional overview... 3 2 Device technology...

More information

Basics of Dimming. ISC Learning Centre

Basics of Dimming. ISC Learning Centre ISC Learning Centre July 2009 > Dimmers Contents What is a dimmer? Dimmers & customer benefits Dimmers at home Dimmers at the office Dimmers: technical choices Overview of the Schneider Electric offer

More information

Passion for KNX innovation

Passion for KNX innovation Passion for KNX innovation Touch-MyDesign 2 Touch-MyDesign is a KNX switch with capacitive buttons that satisfies the design requirements of any building thanks to its total customization: Everyone can

More information

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers An intelligent physical infrastructure is required

More information

Product Information Fire alarm panel 8000 C

Product Information Fire alarm panel 8000 C Product Information Fire alarm panel 8000 C Fire alarm panel 8000 C, basic configuration In common with all modern Esser panels, the 8000 C fire alarm panel is based on high-performance ringbus technology.

More information

User and installation manual

User and installation manual User and installation manual aquaero 5 The information contained in this manual is subject to change without prior notice. All rights reserved. Current as of April 2011 ENGLISH: PAGE 1 DEUTSCH: SEITE 13

More information

NEW. EVEN MORE data acquisition and test stand automation

NEW. EVEN MORE data acquisition and test stand automation NEW EVEN MORE data acquisition and test stand automation the new class of data The plug&play complete package User benefits Expert Series is the latest generation of data acquisition Complete hardware

More information

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485. IntesisBox KNX SAMSUNG Air Conditioning Gateway for integration of Samsung air conditioners into KNX control systems. Integrate Samsung Air Conditioners into KNX. KNX EIB Bus IntesisBox RS485 MIM-B13x/B04A

More information

CONTENTS. Section 1 Document Descriptions... 3. 1.1 Purpose of this Document... 3. 1.2 Nomenclature of this Document... 3

CONTENTS. Section 1 Document Descriptions... 3. 1.1 Purpose of this Document... 3. 1.2 Nomenclature of this Document... 3 CONTENTS Section 1 Document Descriptions... 3 1.1 Purpose of this Document... 3 1.2 Nomenclature of this Document... 3 Section 2 Solution Overview... 5 2.1 General Description... 5 2.2 Hardware and Software

More information

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps Solar Home System User Manual AEHSHS0110W2L Solar Home System 2 Lamps All rights reserved Specifications subject to change without prior notice 2 Dear Customer, Thank you for purchasing Schneider Electric

More information

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6 L-LAS Series L-LAS-LT-165-CL - Line laser 1 mw, laser class 2 - Visible laser line (red light 670 nm), typ. 2 mm x 3 mm - Reference distance approx. 165 mm - Measuring range typ. 65... 265 mm - Resolution

More information

Product data base 2.63 (ETS2 1.2 ETS3.0c / vd2-file) Instabus KNX/EIB System

Product data base 2.63 (ETS2 1.2 ETS3.0c / vd2-file) Instabus KNX/EIB System Audio Audio actuator 4fold 0531 00 Audio actuator 4fold Audio actuator mono Audio actuator stereo Communication Infrared 0588.. IR converter IR transmission/reception C00701 Radio 0868 00 Radio-instabus

More information

Digital display DA 48

Digital display DA 48 Loop powered plug-in LCD display No auxiliary energy source needed Scale freely adjustable on site Can be turned to any position Suitable for any 0 ma transmitter with EN 175301-803A connector Digital

More information

INTELLIGENT BUILDINGS BUS SYSTEMS, MyHOME. Ján Cigánek, Martin Janáček, Stanislav Števo

INTELLIGENT BUILDINGS BUS SYSTEMS, MyHOME. Ján Cigánek, Martin Janáček, Stanislav Števo INTELLIGENT BUILDINGS BUS SYSTEMS, MyHOME Ján Cigánek, Martin Janáček, Stanislav Števo Slovak University of Technology Ilkovičova 3, 812 19 Bratislava, Slovak Republic Tel.: +421 2 60291111 Fax: +421 2

More information

Index. ROPIX P18 Hardware... 3. ROPIX P18 Software... 12 ROPIX P18

Index. ROPIX P18 Hardware... 3. ROPIX P18 Software... 12 ROPIX P18 Index ROPIX P18 Hardware... 3 I. ROPIX P18 Profile Overview... 3 II. Parameter... 5 Sending Card... 6 Receiving Card... 8 Maintenance Tools... 8 III. ROPIX P18 Installation... 9 Cabinet Assembly... 9 Controlling

More information

GSM HOME SECURITY SYSTEM

GSM HOME SECURITY SYSTEM Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : GSM-120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5.

More information

HDMI Matrix Switch USER MANUAL VM0404H

HDMI Matrix Switch USER MANUAL VM0404H HDMI Matrix Switch USER MANUAL VM0404H FCC Information This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits

More information

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5 Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis

More information

LS-1 Series Tungsten Halogen Light Sources Installation and Operation Instructions

LS-1 Series Tungsten Halogen Light Sources Installation and Operation Instructions LS-1 Series Tungsten Halogen Light Sources Installation and Operation Instructions Description The LS-1 Series of tungsten halogen light sources are versatile, white-light lamps optimized for use in the

More information

VENTIsupport Version 1

VENTIsupport Version 1 Description and Operating Instructions VENTIsupport Version 1 Compliance and titration software Content 1. Description.............................2 1.1 Purpose............................2 1.2 Labelling............................2

More information

8-Port HDMI Switch USER MANUAL VS0801H

8-Port HDMI Switch USER MANUAL VS0801H 8-Port HDMI Switch USER MANUAL VS0801H FCC Information This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits

More information

1 Technical Description Lokal-200PC

1 Technical Description Lokal-200PC 1 Technical Description Lokal-200PC 1.1 Overview laptop with in-built accummulator USB connection correlator box internal power supply laptop (if the device has been supplied by F.A.S.T.) BNC aerial connection

More information

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011 , 2CDG 110 1xx R0011 SA/S 8.16.6.1 2CDC 071 006 S0010 The 16/20 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are especially

More information

WEB log. Device connection plans

WEB log. Device connection plans WEB log LIGHT+ 20 BASIC 100 PRO unlimited Device connection plans Version 20151210* Copyright Copyright for this manual remains with the manufacturer. No part of this manual may be reproduced or edited,

More information

QUICK START GUIDE. SG2 Client - Programming Software SG2 Series Programmable Logic Relay

QUICK START GUIDE. SG2 Client - Programming Software SG2 Series Programmable Logic Relay QUICK START GUIDE SG2 Client - Programming Software SG2 Series Programmable Logic Relay SG2 Client Programming Software T he SG2 Client software is the program editor for the SG2 Series Programmable Logic

More information

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11 Communication Unit 560CMD11 The SLC works as master for the RTU560 serial peripheral bus (I/O-Interface/ Wired-OR-Bus ). The MPU is responsible for the other tasks. The MPU handles the absolute time and

More information

WinProladder software package

WinProladder software package WinProladder software package Windows based FATEK FBs-PLC Ladder Program Programming Software General Feature Windows based application program, all the operating follow the convention of windows environment,

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Solutions for E-Mobility

Solutions for E-Mobility Solutions for E-Mobility Qatar PHOENIX CONTACT in dialog with customers and partners worldwide Phoenix Contact is a worldwide market leader in the field of electrical engineering, electronics, and automation.

More information

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series Programmable Terminal NPSeries Easy Setup with the Low-cost, Compact NP Series Simpler and More Versatile.OMRON s Compact NP Series Connect! Easier connection to OMRON PLCs and Temperature Controllers,

More information

Charge Controller CC611/CC612 Preliminary datasheet

Charge Controller CC611/CC612 Preliminary datasheet Preliminary datasheet Preliminary datasheet CC61x_D00xxx_00_D_XXE_preliminary/04.2015 Product description The ender charge controller CC611 is the main component of a charging point and is designed for

More information

Heating Controller. Building Technologies HVAC Products

Heating Controller. Building Technologies HVAC Products 2 474 Heating Controller RVP300 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones with or

More information

Software and Display instruments

Software and Display instruments Software and Display instruments 272 Overview Software and Display instruments 276 VEGA Inventory System 278 DTM Collection und PACTware 279 VEGACONNECT 280 PLICSCOM, PLICSLED 282 VEGADIS 81, 82, 176 271

More information

ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1

ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Product Manual ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Intelligent Installation Systems Contents Page 1 Introduction.......................................

More information

KNX Panasonic Air Conditioners

KNX Panasonic Air Conditioners IntesisBox KNX Panasonic Air Conditioners Gateway for Panasonic ECOi and PACi system integration into KNX networks Up to 30 Outdoor units Up to 64 Indoor units PA-AC-KNX-64/128 EIA485 U1U2 line U1U2 line

More information

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772

More information