1 PRIMERGY PRIMERGY TX150 S3 Server System Options Guide Susanne Däschlein Fujitsu Siemens Computers GmbH München München Tel.: (089) Fax: (++49) 700 / U41604-Z Sprachen: En Edition January 2005
2 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs. Fax forms for sending us your comments are included in the back of the manual. There you will also find the addresses of the relevant User Documentation Department. Certified documentation according to DIN EN ISO 9001:2000 To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001:2000. cognitas. Gesellschaft für Technik-Dokumentation mbh Copyright and Trademarks Copyright 2005 Fujitsu Siemens Computers GmbH. All rights reserved. Delivery subject to availability; right of technical modifications reserved. All hardware and software names used are trademarks of their respective manufacturers. This manual is printed on paper treated with chlorine-free bleach.
3 Introduction Procedure Safety notes Preparation Main memory Accessible drives Controller in the PCI slots RemoteView components External SCSI interface Conversion standard PS to hot-plug PS Continued
4
5 Converting from the floorstand model to the rack model Completion Appendix Abbreviations, Related publications and Index
6
7 Contents 1 Introduction Overview of the documentation Extensions and conversions Notational conventions Procedure Safety notes Preparation Floorstand model Opening the server Removing the front cover Removing the hard disk cover Rack model Opening the server Removing the rack front cover Main memory Equipping rules Extending/replacing the main memory Accessible drives Installing an accessible 5.25-inch drive Installing the hard disks extension box Controller in the PCI slots Installing a controller PCI slot assembling RemoteView components RemoteView Service Board S2 LP External SCSI interface Installing the external SCSI interface Conversion standard PS to hot-plug PS Converting from the floorstand model to the rack model Completion Floorstand model U41604-Z Options Guide
8 Contents Attaching the hard disk cover Attaching the front cover Closing the server Rack model Attaching the rack front cover Closing the server Appendix Cabling SCSI version SATA version Abbreviations Related publications Index Options Guide U41604-Z
9 1 Introduction The PRIMERGY TX150 S3 Server is an Intel-based server for medium-sized networks and large companies. The server is suitable for use as a file server as well as an application, information, or Internet server. It is available as a floorstand or rack model. The floorstand model can be converted to a rack model using an optional conversion kit. 1.1 Overview of the documentation I PRIMERGY manuals are available in PDF format on the ServerBooks CD which is supplied in the ServerView Suite package for every server system. These PDF files can also be downloaded free of charge from the Internet: at you will find an overview page with the online documentation available on the Internet. You can go to the PRIMERGY Server documentation by clicking on intel based Servers. Concept and target groups This Options Guide shows you how you can expand and upgrade the server. I The Operating Manual for the server describes how you install/remove the hot-plug components. The activities described in this manual may only be performed by technicians, service personnel or technical specialists. Additional documentation about the server The PRIMERGY TX150 S3 documentation comprises the following additional manuals: The Security manual (printed copy always supplied with the server, and available as a PDF file on the ServerBooks CD supplied) The Guarantee manual (printed copy always supplied with the server, and available as a PDF file on the ServerBooks CD supplied) The Operating Manual for the PRIMERGY TX150 S3 (PDF available on the ServerBooks CD supplied) U41604-Z Options Guide 1
10 Extensions and conversions Introduction The Technical Manual for the system board D1979 (PDF available on the ServerBooks CD supplied) The BIOS Setup manual (PDF available on the ServerBooks CD supplied) The PRIMERGY ServerView Suite - ServerStart manual (printed copy always supplied with the server, and available as PDF file on the ServerBooks CD supplied) The Global Array Manager Client Software User s Guide (PDF available on the ServerBooks CD supplied) The Integrated Mirroring User s Guide (PDF available on the ServerBooks CD supplied) I You can order a supplementary ServerBooks CD by sending an to the following address, quoting your server data: [email protected] Further sources of information: Technical Manual on the relevant rack Manual on the monitor Manual on ServerView Server Management Manual on the RemoteView Remote Test and Diagnostics System Documentation on boards and drives Documentation on your operating system Information files on your operating system (see also Related publications on page 79) 1.2 Extensions and conversions Extension of the main memory The four slots for the main memory are suitable for DDR1 333/400 MHz (unbuffered) SDRAM memory modules. The organization in two memory banks, 1 and 2, permits rapid memory access with two-way interleaving. If the memory modules are populated in pairs, each pair must consist of identical memory modules (2-way interleaved mode). Additional SATA hard disk drives In the SATA version four bays are available for SATA hard disk drives. 2 Options Guide U41604-Z
11 Introduction Extensions and conversions Additional accessible drives Three 5.25-inch bays are available for accessible drives. The top side bay is already occupied by a CD/DVD ROM drive. Hard disks extension box In the SCSI version the two lower 5.25-inch bays for accessible drives can be used to integrate a hard disks extension box. The hard disks extension box enables up to three additional HDD modules to be integrated. Each HDD module can accommodate a SCSI hard disk drive with an SCA (Single Connector Attachment) interface and a height of at most 1 inch. The connection to the SCSI backplane is made without cables via the SCA interface. This makes it simple to plug in or pull out the HDD modules. If the server has a RAID controller and the corresponding RAID configuration, defective HDD modules can also be replaced while the system is operating. Additional controllers in the PCI slots The system board offers six PCI slots: 2 x PCI-X (64 Bit / 66 MHz), 3 x PCI (32 Bit / 33 MHz) and 1 x PCI-Express x1 slot. The PCI slot 2 is prepared for Zero Channel RAID (ZCR). RemoteView Service Board S2 LP The RemoteView Service Board S2 LP (RSB S2 LP) is a PCI board with a completely independent system, i.e. it has its own operating system with Web server and SNMP agents and can optionally be equipped with an external power supply. The RSB S2 LP permits remote diagnosis for system analysis, remote system configuration and remote restart even in the event of operating system failure or hardware faults. It has its own LAN connection and its own COM port. All the functions of the RSB S2 LP are thus available either via a LAN or modem. External SCSI interface If the internal hard disks are connected via a PCI RAID controller, one channel of the on-board controller can also be made available for connecting a peripheral cabinet SX10 via an external SCSI interface. U41604-Z Options Guide 3
12 Notational conventions Introduction Conversion standard power supply to hot-plug power supply The standard power supply can be replaced by a hot-plug power supply. The hot-plug power supply consists of two power supply modules. If one power supply module fails, the other power supply module guarantees the unrestricted operation and the defective power supply module can be replaced be replaced while the system is operating (hot-plug). Conversion of the floorstand model to a rack model The floorstand model can optionally be converted so that the server can be integrated into the common rack systems. 1.3 Notational conventions The following notational conventions are used in this manual: Text in italics Quotation marks V CAUTION! I indicates commands, menu items or software programs. indicate names of chapters and terms that are being emphasized. describes activities that must be performed in the order shown. pay particular attention to texts marked with this symbol. Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data. indicates additional information, notes and tips. Table 1: Notational conventions 4 Options Guide U41604-Z
13 2 Procedure V CAUTION! The actions described in these instructions should only be performed by technicians, service personnel or technical specialists. Equipment repairs should only be performed by authorized, qualified staff. Any unauthorized opening and improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) and could also damage the equipment. Please note that any unauthorized opening of the device will result in the invalidation of the warranty and exclusion from all liability. First of all please familiarize yourself with the safety instructions in the section chapter Safety notes on page 7 et seqq.. Ensure that all required manuals (see Additional documentation about the server on page 1) are available, printing out the PDF files if necessary. You will definitely need the Operating Manual for the server and the Technical Manual for the system board. Shut down the server correctly, switch it off, pull out the power plug(s), and open the server as described in the chapter Preparation on page 13 et seqq.. Extend or upgrade your server as described in the relevant chapter. I The Operating Manual for the server describes how you install/remove the hot-plug components. I Procedures which are identical for the floorstand and rack models are only described for the floorstand model. Close the server, connect it to the power outlet, and switch it on as described in the chapter Completion on page 59 et seqq.. Start the operating system and, if necessary, configure it as required (see the Operating Manual). U41604-Z Options Guide 5
14
15 3 Safety notes I The following safety notes are also provided in the Safety manual. This device complies with the relevant safety regulations for data processing equipment. If you have any questions about where you can set up the device, contact your sales outlet or our customer service team. V CAUTION! The actions described in these instructions should only be performed by technicians, service personnel or technical specialists. Equipment repairs should only be performed by authorized, qualified staff. Any unauthorized openings and improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) and could also damage the equipment. Please note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability. Before operating the device V CAUTION! During installation and before operating the device, observe the instructions on environmental conditions for your device. If the device is brought in from a cold environment, condensation may form both inside and on the outside of the machine. Wait until the device has acclimatized to room temperature and is absolutely dry before starting it up. Material damage may be caused to the device if this requirement is not observed. Transport the device only in the original packaging or in packaging that protects it from knocks and jolts. U41604-Z Options Guide 7
16 Safety notes Installation and operation V CAUTION! If the rack model is integrated in an installation that receives power from an industrial (public) power supply network with the IEC309 connector, the (public) power supply protection must comply with the requirements for the non-industrial (public) power supply networks for the type A connector. The server automatically sets itself to a voltage in the range of 100 V to 240 V. Make sure that your local voltage is within this range. This device has a specially approved power cable and must only be connected to a grounded insulated socket. Ensure that the power socket on the device or the grounded wall outlet is freely accessible. The ON/OFF button does not disconnect the device from the mains voltage. To disconnect the line voltage completely, remove the power plug(s) from the grounded insulated socket(s). V CAUTION! Always connect the device and the attached peripherals to the same power circuit. Otherwise you run the risk of losing data if, for example, the central processing unit is still running but the peripheral device (e.g. storage subsystem) has failed during a power outage. Data cables to peripheral devices must be adequately shielded. To the LAN wiring the requirements apply in accordance with the standards EN and EN /2. As minimum requirement the use of a protected LAN line of category 5 for 10/100 MBps Ethernet, and/or of category 5e for Gigabit Ethernet is considered. The requirements of the specification ISO/IEC are to be considered. Route the cables in such a way that they do not form a potential hazard (make sure no-one can trip over them) and that they cannot be damaged. When connecting up a device, refer to the relevant notes in this manual. Never connect or disconnect data transmission lines during a storm (lightning hazard). 8 Options Guide U41604-Z
17 Safety notes In emergencies (e.g. damaged casing, controls or cables, penetration of liquids or foreign matter), switch off the device immediately, remove the power plug and contact your sales outlet or customer service team. Proper operation of the device (in accordance with IEC 60950/ EN 60950) is only ensured if the casing is completely assembled and the rear covers for the installation openings have been put in place (electric shock, cooling, fire protection, interference suppression). Only install system expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and relating to telecommunications terminal equipment. If you install other expansions, you may damage the system or violate the safety regulations and regulations governing RFI suppression. Information on which system expansions are suitable can be obtained from the customer service centre or your sales outlet. V CAUTION! The components or parts marked with a warning label (e.g. lightning symbol) may only be opened, removed or exchanged by authorized, qualified personnel. The hot-plug power supply units are exceptions to this rule. The warranty expires if the device is damaged during the installation or replacement of system expansions. You may only set those resolutions and refresh rates specified in the Technical data section of the monitor description. Otherwise, you may damage your monitor. If you are in any doubt, contact your sales outlet or customer service centre. U41604-Z Options Guide 9
18 Safety notes Batteries V CAUTION! Incorrect replacement of batteries may lead to a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer (see the technical manual for the system board under Related publications on page 79). Do not throw batteries into the trash can. They must be disposed of in accordance with local regulations concerning special waste. The battery must be disposed of in accordance with local regulations concerning special waste. Replace the lithium battery on the system board in accordance with the instructions in the technical manual for the system board (see Related publications on page 79). All batteries containing pollutants are marked with a symbol (a crossed-out garbage can). In addition, the marking is provided with the chemical symbol of the heavy metal decisive for the classification as a pollutant: Cd Cadmium Hg Mercury Pb Lead 10 Options Guide U41604-Z
19 Safety notes Notes on handling CDs and CD-/DVD-ROM drives V CAUTION! Use only CDs in proper condition in the CD-/DVD-ROM drive of your server to prevent data loss, damage to the device and injuries. Therefore, check each CD for damage, cracks, breakage etc. before inserting it in the drive. Please note that any additional labels applied may change the mechanical properties of a CD and cause imbalance. Damaged and imbalanced CDs can break at high drive speeds (data loss). Under certain conditions sharp-edged pieces of broken CDs can penetrate the cover of the drive (damage to the device) and be thrown out of the device (danger of injury, particularly on uncovered body parts such as the face or neck). I You protect the CD-/DVD-ROM drive and prevent mechanical damage, as well as premature wearing of the CDs, by observing the following suggestions: Only insert the CDs in the drive when needed and remove them after use. Store the CDs in suitable sleeves. Protect the CDs from exposure to heat and direct sunlight. Note about the laser The CD-/DVD-ROM drive is classified for laser class 1according to IEC V CAUTION! The CD-/DVD-ROM drive contains a laser diode (LED). Sometimes the LED produces a stronger laser beam than laser class 1. Direct view into this laser beam is dangerous. Never remove parts of the CD-/DVD-ROM drive assembly! U41604-Z Options Guide 11
20 Safety notes Modules with electrostatic-sensitive components: Systems and components that might be damaged by electrostatic discharge (ESD) are marked with the following label: Figure 1: ESD label When you handle components fitted with ESDs, you must observe the following points under all circumstances: Remove the power plug from the power socket before inserting or removing components containing ESDs. You must always discharge yourself of static charges (e.g. by touching a grounded object) before working. The equipment and tools you use must be free of static charges. Only touch the components at the positions highlighted in green (touch points). Do not touch any exposed pins or conductors on a component. Use a grounding cable designed for this purpose to connect yourself to the system unit as you install components. Place all components on a static-safe base. I You will find a detailed description for handling ESD components in the relevant European or international standards (DIN EN , ANSI/ESD S20.20). 12 Options Guide U41604-Z
21 4 Preparation V CAUTION! Observe the safety instructions in the chapter Safety notes on page 7 et seqq Floorstand model Opening the server Terminate all applications and shut down the server correctly. If your operating system has not switched off the sever, press the on/off switch. Pull all power connectors out of the power outlets. If required, remove the lock on the side cover Figure 2: Loosening the screws Unlock the server (1). Loosen the two screws at the rear side (2). Push back the left-hand side cover approxiate 2 cm (3). Remove the left-hand side cover (4). U41604-Z Options Guide 13
22 Floorstand model Preparation Removing the front cover Remove the front cover when making the following extensions and upgrades: Installing further accessible drives Upgrading the floorstand model to a rack model Remove the hard disk cover as shown in figure 5 on page 15. Figure 3: Removing the front cover 1 2 Disengage the three tabs (1) on the left side one after the other and rotate the front cover outward (2) about 2 cm. 2 1 Figure 4: Removing the front cover Press the two hooks (1) on the right side inward and pull out the front cover frontward (2). 14 Options Guide U41604-Z
23 Preparation Floorstand model Removing the hard disk cover Remove the hard disk cover when making the following extensions and upgrades: Installing further SATA hard disk drives Terminate all applications and shut down the server correctly. If your operating system has not switched off the sever, press the on/off switch Figure 5: Removing the hard disk cover Unlock the server (1) and remove the key. Push the drive cover up as far as possible (2). Remove the hard disk cover (3 + 4). U41604-Z Options Guide 15
24 Rack model Preparation 4.2 Rack model Terminate all applications and shut down the server correctly. If your operating system has not switched off the server, press the on/off button. Pull all power connectors out of the power outlets Opening the server 1 2 Figure 6: Loosening the knurled screws Loosen the four knurled screws (1) and pull the server as far as possible out of the rack (2). 16 Options Guide U41604-Z
25 Preparation Rack model 2 1 Figure 7: Loosening the locking spring Press in the locking spring (1) on both sides and carefully pull the server outward (2). 2 Figure 8: Removing the server from the rack cabinet Disconnect all cables on the rear of the server. Remove the telescopic rails on the left and right side (three screws). U41604-Z Options Guide 17
26 Rack model Preparation V CAUTION! At least two people are needed to lift the server out of the rack cabinet. Lift the server out of the rails and place it on a table, for example Figure 9: Loosening the screws Unlock the top cover by removing the two screws at the rear side (1). Push back the top cover approxiate 2 cm (2). Remove the top cover (3). 18 Options Guide U41604-Z
27 Preparation Rack model Removing the rack front cover Remove the rack front cover when carrying out the following extension: Installing further accessible drives Figure 10: Removing the rack front cover Remove two screws on either side (1). Remove the rack front cover to the front (2) Figure 11: Removing the plastic front cover Disengage the three tabs (1) on the top side one after the other and pull out the plastic front cover frontward (2) about 2 cm. Press the two hooks (3) on the bottom side downward and pull out the plastic front cover frontward (4). U41604-Z Options Guide 19
28
29 5 Main memory V CAUTION! Observe the safety instructions in the chapter Safety notes on page 7 et seqq.. The system board supports up to 4 Gbytes of main memory. Four slots (2 slots form a memory bank) are provided for the main memory. Each memory bank can be equipped with 256 Mbyte, 512 Mbyte or 1 Gbyte unbuffered DDR I memory modules. 5.1 Equipping rules DIMM 1A DIMM 2A DIMM 1B DIMM 2B Figure 12: Structure of the main memory in memory banks and memory modules Each memory bank is equipped with two memory modules with the same capacity. Memory access takes place in 2-way interleaved mode. The memory module capacity can differ for the various memory banks: e.g. memory bank 2A/2B can be equipped with two 512 Mbyte memory modules, and memory bank 1A/1B with two 1 Gbyte memory modules. U41604-Z Options Guide 21
30 Extending/replacing the main memory Main memory The table below shows the order in which the memory banks must be equipped: DIMM_1A DIMM_2A DIMM_1B DIMM_2B single channel equipped empty empty empty empty equipped empty empty empty empty equipped empty empty empty empty equipped dual channel equipped empty equipped empty empty equipped empty equipped equipped equipped equipped equipped 5.2 Extending/replacing the main memory Open the server as described in the chapter Preparation on page 13 et seqq Figure 13: Removing a memory module Press the holders on either side of the mounting location concerned outward (1). If the mounting location was already equipped: pull the memory module out of the mounting location (2). 22 Options Guide U41604-Z
31 Main memory Extending/replacing the main memory 2 2 Figure 14: Inserting a memory module Press the holders on either side of the mounting location concerned outward. Insert the memory module in the mounting location (1) until the holders at the sides engage (2). Close the server, connect it to the power outlet, and switch it on as described in the chapter Completion on page 59 et seqq.. U41604-Z Options Guide 23
32
33 6 Accessible drives V CAUTION! Observe the safety instructions in the chapter Safety notes on page 7 et seqq.. Three 5.25-inch bays are available for accessible drives. The top side bay is already equipped with a CD/DVD-ROM drive. The two lower bays can also be used to install a hard disks extension box. 6.1 Installing an accessible 5.25-inch drive The 5.25-inch drives available are magnetic tape drives, CD/DVD-ROM drives and CD/DVD-ROM burners. These drives can be installed in the two free inch bays. Open the server and remove the front cover or rack front cover as described in the chapter Preparation on page 13 et seqq.. I New 5.25-inch drives are supplied without EasyClick rails. Before installing a new drive you must therefore remove the EasyClick rails from the dummy cover and mount the EasyClick rails on the new drive Figure 15: Removing the dummy cover Press the two metal tongues of the EasyClick rails inward (1) until the locking mechanism is released. Remove the dummy cover from the bay (2). U41604-Z Options Guide 25
34 Installing an accessible 5.25-inch drive Accessible drives Remove the EasyClick rails from the dummy cover by removing the four screws on each side. I Note that there are two M3 screws and two UNC screws on each side. V CAUTION! Keep the dummy cover for future use. If you remove the accessible drive again and do not replace it with a new one, the dummy cover must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures. 1 1 Figure 16: Attaching the EasyClick rails - DVD-ROM burner Screw the EasyClick rails onto either side of the new 5.25-inch drive using two M3x4.5mm screws (1). Use the first hole in each upper row of holes as shown in the figure. I Keep the remaining screws for future use. The different drives are fastened using different screws. Starting on the next page, you will find figures which show the attaching of the EasyClick rails for magnetic tape drives. Push the new drive about halfway into the bay. Connect the data cable to the accessible drive (see the cabling plans in the Appendix). Connect the power cable to the accessible drive (see the cabling plans in the Appendix). Push the drive fully into the bay until the EasyClick rails latch in place. 26 Options Guide U41604-Z
35 Accessible drives Installing an accessible 5.25-inch drive Attach the front cover or rack front cover, close the server, connect it to the power outlet, and switch it on as described in the chapter Completion on page 59 et seqq.. You will find in the following figures which holes and screws should be used for the magnetic tape dives. Figure 17: Attaching the EasyClick rails - magnetic tape drive LTO Ultrium 1HH Figure 18: Attaching the EasyClick rails - magnetic tape drive LTO Ultrium 2FH U41604-Z Options Guide 27
36 Installing an accessible 5.25-inch drive Accessible drives Figure 19: Attaching the EasyClick rails - magnetic tape drive VXA-2 Figure 20: Attaching the EasyClick rails - magnetic tape drive DDS Gen5 28 Options Guide U41604-Z
37 Accessible drives Installing the hard disks extension box 6.2 Installing the hard disks extension box In the SCSI version the two lower 5.25 inch bays for accessible drives can be used to install a HDD extension box. But it is required that the server is equipped with a 1- or 2-channel RAID controller. I It is not allowed to operate the hard disks of the HDD extension box together with the internal hard disks via one common SCSI line. If the server has a RAID controller and a corresponding RAID configuration, defective hard disk modules can also be exchanged during operation. Open the server and remove the front cover or rack front cover as described in the chapter Preparation on page 13 et seqq.. I The hard disks extension box is supplied without EasyClick rails. You need 8 M3 screws. Before installing a new hard disks extension box you must therefore remove the EasyClick rails from the two dummy covers and mount two of the four EasyClick rails on the hard disks extension box. Remove the dummy covers from the two lower 5.25-inch bays for accessible drives: Press the two metal tongues of the EasyClick rails inward (1) until the locking mechanism is released. Remove the dummy cover from the bay. Remove the EasyClick rails from the two dummy covers by removing the four screws on each side. I Note that there are two M3 screws and two UNC screws on each side. V CAUTION! Keep the dummy covers for future use. If you remove the hard disks extension box again and do not replace it with new drives, the dummy covers must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures. U41604-Z Options Guide 29
38 Installing the hard disks extension box Accessible drives Figure 21: Attaching the EasyClick rails Screw the EasyClick rails onto either side of the hard disks extension box using four M3 screws for each rail. Use the holes marked above for this purpose. Push the hard disks extension box fully into the bay until the EasyClick rails latch in place. Connect the power cable plug P2 to the hard disks extension box. Connect the SCSI cable T26139-Y3927-V1 included in the conversion kit to the SCSI connector on the HDD extension box. Connect the I 2 C cable (T26139-Y3718-V601) with the I²C bus connector of the HDD extension box.. Secure the I 2 C cable with a green clamp. Route the SCSI cable and connect it to the SCSI connector on the 1- or 2-channel RAID controller. Attach the front cover or rack front cover, close the server, connect it to the power outlet, and switch it on as described in the chapter Completion on page 59 et seqq.. 30 Options Guide U41604-Z
39 7 Controller in the PCI slots V CAUTION! Observe the safety instructions in the chapter Safety notes on page 7 et seqq.. The system board offers six PCI slots: 2 x PCI-X (64 Bit / 66 MHz), 3 x PCI (32 Bit / 33 MHz) and 1 x PCI-Express x1 slot. The PCI slot 2 is prepared for Zero Channel RAID (ZCR). PCIe Slot 6 PCI Slot 5 PCI Slot 4 PCI Slot 3 Figure 22: Numbering of the PCI slots PCI Slot 2 PCI Slot 1 PCI slot 64Bit/ 32Bit Frequency in MHz Description 1 32 Bit Bit PCI bus slot 2 64 Bit Bit PCI X bus slot, prepared for ZCR 3 64 Bit Bit PCI X bus slot 4 32 Bit Bit PCI bus slot 5 32 Bit Bit PCI bus slot 6 PCIe x1 bus slot For more information see the Technical Manual of the system board D1979. U41604-Z Options Guide 31
40 Installing a controller Controller in the PCI slots 7.1 Installing a controller Open the server as described in the chapter Preparation on page 13 et seqq Figure 23: Removing the rear cover Swing the locking swivel in the direction of the arrow (1). Press onto the clip (2) and remove it. Remove the PCI slot s rear cover (3). V CAUTION! Keep the rear cover of the PCI slot for future use. If you remove the controller again and do not replace it with a new one, the rear cover must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures. 32 Options Guide U41604-Z
41 Controller in the PCI slots Installing a controller a Figure 24: Installing a controller Install the controller in the PCI slot and press it carefully into the associated plug-in location on the system board (1) until it engages properly. Place the clip on the slot cover in such a way that the pin (a) fits into the hole of the slot cover (2), and press the clip in the direction of the arrow (3) until it engages. Swing the locking swivel (4) in its locking position. If required, connect the cables to the controller and other components. Close the server, connect it to the power outlet, and switch it on as described in the chapter Completion on page 59 et seqq.. U41604-Z Options Guide 33
42 PCI slot assembling Controller in the PCI slots 7.2 PCI slot assembling Install first those controllers which request a defined slot. Then install the PCI- X controllers, then the PCI66 and at least the PCI33 controllers. PCI bus type Quanti ty Preferred slot Forbidden slot 1. Controller for defined slots RemoteView service board S2 LP , 3 2. PCI-X controller 3. PCI 66 MHz controller LSI MegaRaid Zero Channel , 3, 4, 5 LSI MegaRaid Two Channel , 3 1, 2, 4, 5 Emulex LP900SL , 3, 4 2 Qlogic QLA , 3, 4 2 Intel Pro 1000MT Dual Port , 3, 4, 5 Intel Pro 1000MT Server , 3, 4, 5 4. PCI 33 MHz controller Promise TX150 SX Eicon Diehl Diva Bri-2M , 4, 3, 1 Eicon S , 4, 3, 1 Madge MK , 4, 3, 1 Intel Pro 1000MT Desktop , 5 Table 2: PCI slot assembling 34 Options Guide U41604-Z
43 8 RemoteView components V CAUTION! Observe the safety instructions in the chapter Safety notes on page 7 et seqq RemoteView Service Board S2 LP I How to configure the RSB S2 LP is described in detail in the User Guide RemoteView. The preferred mounting location for the RSB S2 is PCI slot 1. The RSB S2 LP is connected to the system board via a power and a data cable. The RSB S2 LP kit contains an external power supply. U41604-Z Options Guide 35
44 RemoteView Service Board S2 LP RemoteView components Open the server as described in the chapter Preparation on page 13 et seqq Figure 25: Connecting cables to the RSB S2 LP Connect the power cable (1) and the data cable (2) to the RSB S2 LP. Install the RSB S2 LP in PCI slot 1 as described in section Installing a controller on page 32. PCI Slot 1 BATTERY 1 2 Figure 26: Connecting cables to the system board Connect the data cable to the connector IPMB (1) and the power cable to the connector RSB LP Power (2) on the system board. 36 Options Guide U41604-Z
45 RemoteView components RemoteView Service Board S2 LP Adapter RSB S2 LP Externe Stromversorgung/ external power supply Figure 27: Connecting external cables 1 connect to USB port of the server 2 connect to LAN port of the network 3 connect to VGA port of the server 4 connect to VGA port of the monitor U41604-Z Options Guide 37
46 RemoteView Service Board S2 LP RemoteView components Connect the external cables and the external power supply as shown in figure 27 on page 37. Close the server, connect it to the power outlet, and switch it on as described in the chapter Completion on page 59 et seqq.. 38 Options Guide U41604-Z
47 9 External SCSI interface V CAUTION! Observe the safety instructions in the chapter Safety notes on page 7 et seqq.. If the internal hard disks are connected via a PCI RAID controller, one channel of the on-board controller can also be made available for connecting a peripheral cabinet SX10 via an external SCSI interface. 9.1 Installing the external SCSI interface Open the server as described in the chapter Preparation on page 13 et seqq.. Figure 28: External SCSI interface Remove the rear cover of PCI slot 7 and insert the slot cover of the external SCSI interface in this slot as described in section PCI slot assembling on page 34. Attach the external SCSI interface s connector to the SCSI channel of the onboard SCSI controller on the system board (connector SCSI U320). Close the server, connect it to the power outlet, and switch it on as described in the chapter Completion on page 59 et seqq.. U41604-Z Options Guide 39
48
49 10 Conversion standard PS to hotplug PS V CAUTION! Observe the safety instructions in the chapter Safety notes on page 7 et seqq.. The standard power supply can be replaced by a hot-plug power supply. The hot-plug power supply consists of up to two power supply modules. The upgrade kit contains only one power supply module (for power supply redundancy the second power supply module must be additionally ordered). The upgrade kit for the hot-plug power supply consists of the following parts: PS cage with Power backplane (incl. power cables) locking rail one power supply unit dummy cover (if only one power supply module is installed, you have to install the dummy cover in the second bay) several screws anti-tilt bracket V CAUTION! After installing the hot-plug power supply the SDR (sensor data record) data base must be updated. For this sequence you need a BIOS flash diskette. This diskette contains the newest BIOS version, the BMC firmware and the SDR data. Write a BIOS flash diskette by down loading the required data from the software pool under Open the server as described in the chapter Preparation on page 13 et seqq.. Disconnect all power cables from the system board and the drives (see the cabling plans in the Appendix). U41604-Z Options Guide 41
50 Conversion standard PS to hot-plug PS 1 1 Figure 29: Loosening the screws Remove the five screws (1) which attach the adapter plate of the standard power supply to the housing. 2 Figure 30: Taking out the standard power supply Slide the standard power supply somewhat toward the inside (1) to detach it from the brackets in the side cover and take it out toward the side (2). 42 Options Guide U41604-Z
51 Conversion standard PS to hot-plug PS Figure 31: Installing the Power backplane in the PS cage Insert the Power backplane in the PS cage. Push the Power backplane in direction of the arrows until the three bolts of the PS cage engage. Fasten the Power backplane with one knurled screw (see the circle). U41604-Z Options Guide 43
52 Conversion standard PS to hot-plug PS Figure 32: Installing the PS cage Push the PS cage from inside into the bay. In the floorstand model the Power backplane is positioned under the top cover, and in the rack model at the right-hand side cover (seen from front side). V CAUTION! Make sure that the two noses of the PS cage (see the arrows) engage in the housing. Ensure that no damage is caused to the cables. 44 Options Guide U41604-Z
53 Conversion standard PS to hot-plug PS Figure 33: Fastening the PS cage in the housing Fasten the PS cage in the housing with one screw M3x4.5 mm (see the circle). U41604-Z Options Guide 45
54 Conversion standard PS to hot-plug PS Figure 34: Fastening the PS cage at the rear side Fix the locking rail with four screws (see the arrows) on the rear side of the server.. Fasten the PS cage with three screws M3x4.5 mm (see the circles) at the rear side. Connect all power cables to the system board and the drives (see the cabling plans in the Appendix). 46 Options Guide U41604-Z
55 Conversion standard PS to hot-plug PS Figure 35: Inserting the power supply module Push the power supply module in the left side (floorstand model) or bottom side (rack model) bay. Lift the green handle somewhat upwards so that the forked levers (see the arrows) can fit to the locking rail. U41604-Z Options Guide 47
56 Conversion standard PS to hot-plug PS Figure 36: Locking the power supply module Push the green handle downward until the locking slide (see the arrow) engages. Plug the power cord to the connector of the power supply module. If you want to install a second power supply module, proceed in the same way. 48 Options Guide U41604-Z
57 Conversion standard PS to hot-plug PS Figure 37: Installing the dummy cover If you have not ordered a second power supply module, install the dummy cover in the second bay: Hook the top side of the dummy cover into the chassis, after this swivel the dummy cover down and fasten it with one screw (see the arrow) to the housing. V CAUTION! For floorstand models with hot-plug power supply the supplied anti-tilt bracket must be fitted at the rear of the server. U41604-Z Options Guide 49
58 Conversion standard PS to hot-plug PS Mounting the anti-tilt bracket (only floorstand model) Attach the left-hand side cover as described in section Closing the server on page Figure 38: Mounting the anti-tilt bracket Position the server on the anti-tilt bracket in the way that the rubber feet of the server fit into the openings of the bracket (1). 50 Options Guide U41604-Z
59 Conversion standard PS to hot-plug PS Figure 39: Fastening the anti-tilt bracket Fasten the anti-tilt bracket using the two knurled screws (1). Close the server, connect it to the power outlet, and switch it on as described in the chapter Completion on page 59 et seqq.. V CAUTION! After installing the hot-plug power supply the SDR (sensor data record) data base must be updated. For this sequence you need the BIOS flash diskette prepared before. This diskette contains the newest BIOS version, the BMC firmware and the SDR data. I You will find the description of the indicators of the power supply module in the Operating Manual for the PRIMERGY TX150 S3. U41604-Z Options Guide 51
60
61 11 Converting from the floorstand model to the rack model V CAUTION! Observe the safety instructions in the chapter Safety notes on page 7 et seqq.. Open the server and remove the front cover as described in the chapter Preparation on page 13ff. I The front cover is no longer required. Figure 40: Removing the anti-tilt bracket If your server is equipped with an anti-tilt bracket, remove it: Remove the two knurled screws (1) and lift the server out of the anti-tilt bracket. U41604-Z Options Guide 53
62 Converting from the floorstand model to the rack model The right-hand side cover and the top cover build one part. Figure 41: Removing the screws Remove the two screws at the rear side. 1 Figure 42: Removing the right-hand side cover Lift the hook up slightly using a screwdriver. Push the right-hand side cover in the direction of the arrow. Lift off the right-hand side cover. I The right-hand side cover is no longer required. 54 Options Guide U41604-Z
63 Converting from the floorstand model to the rack model Lay the server on its right-hand side. V CAUTION! Get a second person to help you do this. The server can weigh up to 40 kg. Figure 43: Removing the rubber feet Remove the two upper rubber feet (see the arrows) on the left side. Remove the three screws (see the circles) and take out the rail with the two lower rubber feet. I The rubber feet and the rail are no longer required. U41604-Z Options Guide 55
64 Converting from the floorstand model to the rack model The drive cage for the accessible drives is constructed in such a way that the accessible drives and the operating panel module can be taken out simply, turned through 90 to the left, and then be reinstalled. Remove the dummy covers from the drive cage (figure 15 on page 25). Unplug the cables from the system board or the accessible drives and remove the drives from the drive cage. Pull the operating panel module forward out of its mounting location until you can pull the the ribbon cable and the USB cable out of the operating panel module. Remove the two cables. Remove the operating panel module. Turn the operating panel module through 90 to the left. Figure 44: Installing the operating panel module Push the operating panel module halfway into the upper bay of the drive cage. Connect the ribbon cable and the USB cable to the operating panel module. Now push the operating panel module fully into the upper bay of the drive cage. Turn the drives removed beforehand through 90 to the left. Turn the dummy covers removed beforehand through 90 to the left. Install the drives and empty covers in the drive cage. Reestablish all connections to the drives. 56 Options Guide U41604-Z
65 Converting from the floorstand model to the rack model Attach the rack front cover, close the server, connect it to the power outlet, and switch it on as described in the chapter Completion on page 59ff. To enable the rack model to be presented correctly in ServerView, proceed as follows: Place the ServerStart CD-ROM in the drive. Under the path \Tools\System Configuration start the SCU_Chassis Model Conversion program and change the server type to "PRIMERGY TX150S3 Rack". U41604-Z Options Guide 57
66
67 12 Completion V CAUTION! Observe the safety instructions in the chapter Safety notes on page 7 et seqq Floorstand model Attaching the hard disk cover After you have installed further SATA hard disk drives, reattach the hard disk cover Figure 45: Attaching the hard disk cover Push the drive cover up as far as possible (1). Reinsert the hard disk cover (2 + 3). Insert the key. Lock the server. Press the on/off key to start up the server. U41604-Z Options Guide 59
68 Floorstand model Completion Attaching the front cover After you have installed further accessible drives, reattach the front cover Figure 46: Attaching the front cover Press the two hooks (1) on the right side in the recesses of the housing. Press the front cover onto the housing (2) until the three tabs on the left side engage (3). Attach the hard disk cover as shown in figure 45 on page Options Guide U41604-Z
69 Completion Floorstand model Closing the server 1 2 Figure 47: Attaching the left-hand side cover Position the left-hand side cover in such a way that it protrudes approxiate 2 cm at the rear (1). Shut the left-hand side cover. Push the left-hand side cover all the way forward (2). 1 Figure 48: Fastening the left-hand side cover Fasten the left-hand side cover with two screws (1). Insert the key. Lock the server. Connect all power plugs to the power outlets. Press the on/off key to start up the server. U41604-Z Options Guide 61
70 Rack model Completion 12.2 Rack model Attaching the rack front cover Reattach the rack front cover after implementing the following extensions: Installation of further accessible drives Conversion of the floorstand model to a rack model Figure 49: Attaching the plastic front cover Press the two hooks (1) on the bottom side in the recesses of the housing. Press the plastic front cover onto the housing (2) until the three tabs on the top side engage (3). 62 Options Guide U41604-Z
71 Completion Rack model Figure 50: Attaching the rack front cover Attach the rack front cover from the front (1). Attach the rack front cover using two screws on each side (2). U41604-Z Options Guide 63
72 Rack model Completion Closing the server Figure 51: Attaching the top cover Position the top cover in such a way that it protrudes approxiate 2 cm at the rear (1). Push the top cover all the way forward (2). Fasten the top cover with two screws (3). 64 Options Guide U41604-Z
73 Completion Rack model If you have not removed the server from the rack cabinet, please skip this page. V CAUTION! At least two people are required to install the server in the rack cabinet. Do not use the handles on the rack front cover to lift the server into the rack. Lower the server from above onto the extended telescopic rails. 2 Figure 52: Installing the server in a rack cabinet Screw the telescopic rails onto the left-hand side (one screw) and right-hand side (two screws) of the server. Reconnect all the cables you disconnected beforehand on the rear of the server. Press in the locking spring on both sides and push the server as far as it will go into the rack. U41604-Z Options Guide 65
74 Rack model Completion 1 Figure 53: Fastening the server in the rack cabinet Fasten the server in the rack using the four knurled screws (1). Connect all power plugs to the power outlets. Press the on/off key to start up the server. 66 Options Guide U41604-Z
75 13 Appendix 13.1 Cabling I The Pn numbers of the power cables are identical for the standard and the redundant power supply. You will not find a special drawing for the power supply cabling SCSI version 1-channel SCSI version with onboard SCSI controller In the basic version the tape drives and the four internal hard disk drives are connected to the onboard SCSI controller via one SCSI cable. 1-channel SCSI version with additional SCSI RAID controller A SCSI RAID controller is installed into a PCI slot and connected with the four internal hard disk drives. In this case, the connection to the onboard SCSI controller must be changed to the RAID controller. The accessible drives must be unplugged from this SCSI cable. After this the accessible drives can be connected to the onboard SCSI controller via an additional SCSI cable. Supplementary channels of the RAID controller are available for external hard disk drive systems. U41604-Z Options Guide 67
76 Cabling Appendix Power supply Y3728-V1 Legend: Power SCSI IDE/FD Data System fan Cable prefix: T P1 P9 P8 Y3718-V508 Y3785-V301 Y1737-V111 Y3736-V1 Y3912-V1 Y3904-V1 Operating panel USB P4 CD/DVD P2 SCSI device P3 SCSI device Y1248-V8 P5 Floppy IDTEMP 1" HDD SCSI HD ID3 P6 X6 X7 SCSI HD ID2 SCSI HD ID1 X5 SCSI HD ID0 Intrusion sw. Intrusion sw. SCSI backplane 1-channel Figure 54: Cabling 1-channel SCSI version with onboard SCSI controller 68 Options Guide U41604-Z
77 Appendix Cabling Power supply Y3728-V1 Legend: Power SCSI IDE/FD Data System fan Cable prefix: T P8 P1 P9 Y3718-V508 Y3912-V1 Y3904-V1 Y1737-V111 free Y1248-V8 IDTEMP Y3859-V11 Y3736-V1 Y2361-V102 Intrusion sw. Intrusion sw. P6 X6 X7 Y3785-V301 X5 SCSI RAID controller Operating panel USB P4 CD/DVD P2 SCSI device P3 SCSI device P5 Floppy 1" HDD SCSI HD ID3 SCSI HD ID2 SCS HD ID1 SCSI HD ID0 SCSI backplane 1-channel Figure 55: Cabling 1-channel SCSI version with additional SCSI RAID controller U41604-Z Options Guide 69
78 Cabling Appendix Power supply Y3728-V1 Legend: Power SCSI IDE/FD Data System fan Cable prefix: T P1 P9 P8 Y3718-V508 Y3785-V301 Y1737-V111 Y3927-V1 RAID controller Y3736-V1 Y3912-V1 Y3904-V1 Operating panel USB P4 CD/DVD P3 P2 Hard disk extension box Y1248-V8 P5 Floppy IDTEMP 1" HDD SCSI HD ID3 P6 X6 X7 SCSI HD ID2 SCSI HD ID1 X5 SCSI HD ID0 Intrusion sw. Intrusion sw. SCSI backplane 1-channel Figure 56: Cabling hard disk extension box 70 Options Guide U41604-Z
79 Appendix Cabling SATA version Power supply Y3728-V1 Legend: Power SCSI IDE/FD Data System fan Cable prefix: T P8 P1 P9 Y3718-V508 Y2361-V102 Y3895-V11 SCSI RAID controller Y3736-V1 Y3912-V1 Y3904-V1 Operating panel USB Y1737-V111 P4 CD/DVD P2 SCSI device P3 SCSI device Y1248-V8 P5 Floppy IDTEMP free Intrusion sw. Intrusion sw. 4 x Y3928-V SATA controller P6 X9 X8 X6 X10 X4 X2 X11 1" HDD SATA HD 3 SATA HD 2 SATA HD 1 SATA HD 0 SATA backplane Figure 57: Cabling with additional SATA controller U41604-Z Options Guide 71
80
81 Abbreviations AC ANSI Alternating Current American National Standard Institut ASR&R Automatic Server Reconfiguration and Restart BIOS BMC CC CD Basic Input-Output System Baseboard Management Controller Cache Coherency Compact Disk CD-ROM Compact Disk-Read Only Memory CHS Cylinder Head Sector CMOS Complementary Metal Oxide Semiconductor COM CPU DC Communication Central Processing Unit Direct Current DIMM Dual Inline Memory Module U41604-Z Options Guide 73
82 Abbreviations DIP DMA DMI ECC ECP Dual Inline Package Direct Memory Access Desktop Management Interface Errror Checking and Correcting Extended Capabilities Port EEPROM Electrically Erasable Programmable Read-Only Memory EMC EMP EPP ESD FPC FRU FSB GAM GUI ElectroMagnetic Compatibility) Emergency Management Port Enhanced Parallel Port ElectroStatic Discharge Front Panel Controller Field Replaceable Unit Front Side Bus Global Array Manager Graphical User Interface 74 Options Guide U41604-Z
83 Abbreviations HDD HSC I²C I/O ICM ID IDE IOOP IRQ LAN LBA LCD LUN LVD MMF Hard Disk Drive Hot-Swap Controller Inter-Integrated Circuit Input/Output Intelligent Chassis Management Identification Intergrated Drive Electronics Intetelligent Organization of PCI Interrupt Request Line Local Area Network Logical Block Address Liquid Crystal Display Logical Unit Number Low-Voltage Differential SCSI Multi Mode Faser U41604-Z Options Guide 75
84 Abbreviations MRL NMI Manually Retention Latch Non Maskable Interrupt NVRAM Non Volatile Random Access Memory OS PCI PDA Operating System Peripheral Component Interconnect Prefailure Detection and Analysing POST Power ON Self Test RAID RAM ROM RSB RTC Redundant Arrays of Independent Disks Random Access Memory Read-Only Memory Remote Service Board Real Time Clock RTDS Remote Test- und Diagnose-System SAF-TE SCSI Accessed Fault-Tolerance Enclosures SBE Single Bit Error 76 Options Guide U41604-Z
85 Abbreviations SCA SCSI Single Connector Attachment Small Computer System Interface SDDC Single Device Data Correction SDR Sensor Data Record SDRAM Synchronous Dynamic Random Access Memory SEL SMI SSU System Event Log System Management Interrupt System Setup Utility SVGA Super Video Graphics Adapter USB VGA Universal Serial Bus Video Graphics Adapter U41604-Z Options Guide 77
86
87 Related publications PRIMERGY manuals are available as PDF file on the ServerBooks CD. The ServerBooks CD is part of the ServerView Suite delivered with each server system. The actual version of the necessary manuals can be downloaded free of charge from the Internet. The overview page showing the online documentation available in the Internet can be found via the URL: (choose: intel based servers/primergy ServerBooks). [1] Safety [2] Warranty [3] PRIMECENTER Rack Technical Manual [4] DataCenter Rack Technical Manual [5] 19 inch rack Technical Manual [6] PRIMERGY ServerView Suite ServerStart [7] ServerView Server Management User Manual [8] ServerView Extension ServerView Extension for HP OpenView NNM [9] ServerView/Plus for Tivoli [10] RemoteView User Manual [11] PRIMERGY TX150 S3 Operating Manual [12] System Board D1979 Technical Manual [13] BIOS-Setup Reference Manual U41604-Z Options Guide 79
88 Related Publications [14] Integrated Mirroring User s Guide [15] Global Array Manager Client Software User s Guide [16] Configurator For partners and distributors only: 80 Options Guide U41604-Z
89 Index A accessible drives 3, 25 C controller 3, 32 conversion of floorstand module to rack model 4 conversion standard power supply to hot-plug power supply 4 Conversion standard PS to hot-plug PS 41 R rack front cover 19, 62 RemoteView Service Board S2 LP 3, 35 S SATA hard disk drives 2 T target group 1 E ESD (devices sensitive to electrostatic discharge) 12 external SCSI interface 3, 39 F floorstand to rack model conversion 53 front cover 14, 60 H hard disk cover 15, 59 hard disks extension box 3, 29 I information material 2 L light-emitting diode (LED) 11 lithium battery 10 M main memory 2, 21 meaning of the symbols 4 N notational conventions 4 note about the laser 11 U41604-Z Options Guide 81
90
91 Fujitsu Siemens Computers GmbH User Documentation München Germany Fax: (++49) 700 / Comments Suggestions Corrections [email protected] Submitted by Comments on PRIMERGY TX150 S3 Server System U41604-Z
92
93 Fujitsu Siemens Computers GmbH User Documentation München Germany Fax: (++49) 700 / Comments Suggestions Corrections [email protected] Submitted by Comments on PRIMERGY TX150 S3 Server System U41604-Z
94
95 Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Computers. This new subsidiary of Fujitsu has been renamed Fujitsu Technology Solutions. This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed. Please note that all company references and copyrights in this document have been legally transferred to Fujitsu Technology Solutions. Contact and support addresses will now be offered by Fujitsu Technology Solutions and have the The Internet pages of Fujitsu Technology Solutions are available at and the user documentation at Copyright Fujitsu Technology Solutions, 2009 Hinweise zum vorliegenden Dokument Zum 1. April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen. Diese neue Tochtergesellschaft von Fujitsu trägt seitdem den Namen Fujitsu Technology Solutions. Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nicht mehr im Vertrieb befindliche Produktversion. Bitte beachten Sie, dass alle Firmenbezüge und Copyrights im vorliegenden Dokument rechtlich auf Fujitsu Technology Solutions übergegangen sind. Kontakt- und Supportadressen werden nun von Fujitsu Technology Solutions angeboten und haben die Die Internetseiten von Fujitsu Technology Solutions finden Sie unter und unter finden Sie die Benutzerdokumentation. Copyright Fujitsu Technology Solutions, 2009
PRIMERGY TX100 S1. Options Guide
PRIMERGY TX100 S1 Options Guide Edition August 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our
PRIMERGY Econel 50 Server System
PRIMERGY PRIMERGY Econel 50 Server System Service Supplement Xenia Fierley Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: [email protected] Tel.: (089) 61001-157 Fax: 0 700
Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001
Express5800/120Ed Rack Mount Kit Installation Procedures PN: 455-01607-001 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,
Compaq Presario Desktop Products. Upgrading and Servicing Guide
Compaq Presario Desktop Products Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to
Upgrading and Servicing Guide
Upgrading and Servicing Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should be construed
UPGRADING AND SERVICING GUIDE
UPGRADING AND SERVICING GUIDE HPTouchSmart 610 PC Computer features may vary by model. Removing and Replacing a CD/DVD Drive...2 Removing the CD/DVD Drive... 2 Installing a New CD/DVD Drive... 5 Removing
StorTrends 3400 Hardware Guide for Onsite Support
StorTrends 3400 Hardware Guide for Onsite Support MAN-3400-SS 11/21/2012 Copyright 1985-2012 American Megatrends, Inc. All rights reserved. American Megatrends, Inc. 5555 Oakbrook Parkway, Building 200
HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in
HP Pavilion All-in-One MS200 series PC *579907-001* *579907-001* Printed in Upgrading and Servicing Guide Replacing a Wireless Keyboard or Mouse...2 Before You Begin... 2 Replacing the Keyboard or Mouse...
Service Guide. Gateway M275
Service Guide Gateway M275 Contents Replacing Gateway M275 Components.................................... 1 Identifying the convertible tablet PC model...................................... 2 Identifying
TS500-E5. Configuration Guide
TS500-E5 Configuration Guide E4631 Second Edition V2 March 2009 Copyright 2009 ASUSTeK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software described in it, may
HP SATA/SAS hard drive and Solid State Drive installation
HP SATA/SAS hard drive and Solid State Drive installation This document describes how to install Serial ATA (SATA) and Serial Attached SCSI (SAS) hard drives or Solid State Drives (SSD) in an internal
Small form factor bay converter and hard drive installation
Small form factor bay converter and hard drive installation HP xw6600 and HP xw8600 Workstations This document describes how to convert HP xw6600 and HP xw8600 Workstation 3.5-inch hard drive bays to hold
User Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC)
User Guide - English FUJITSU Software ServerView Suite Local Service Panels Local Service Concept (LSC) Edition February 2013 Comments Suggestions Corrections The User Documentation Department would like
HP ProLiant DL165 G7 Server. Installation Instructions
HP ProLiant DL165 G7 Server Installation Instructions Identifying server components Front panel components Figure 1 Front Panel Components / 4 3.5 HDD Item 1 Thumbscrews for rack mounting 2 Drive status
Power Supply Guide Version 1.0 for D-Show
Power Supply Guide Version 1.0 for D-Show Digidesign 2001 Junipero Serra Boulevard Daly City, CA 94014-3886 USA tel: 650 731 6300 fax: 650 731 6399 Technical Support (USA) tel: 650 731 6100 fax: 650 731
ProLiant DL380 Generation 2 Server Maintenance and Service Guide
ProLiant DL380 Generation 2 Server Maintenance and Service Guide Second Edition (June 200) Part Number 203840-002 Spare Part Number 228520-00 Compaq Computer Corporation Notice 200 Compaq Computer Corporation
Options Guide - English PRIMERGY TX100 S2. Options Guide
Options Guide - English PRIMERGY TX100 S2 Options Guide July 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps
3.5 Dual Bay USB 3.0 RAID HDD Enclosure
3.5 Dual Bay USB 3.0 RAID HDD Enclosure User Manual August 11, 2011 v1.1 MFG Part # MT2U3-MP BARCODE Introduction 1 Introduction 1.1 System Requirements 1.1.1 PC Requirements Minimum Intel Pentium III
4x3.5" Hot-Swap Drive Cage Kit Installation Guide for Intel Server Chassis/System
4x3.5" Hot-Swap Drive Cage Kit Installation Guide for Intel Server Chassis/System Order Number: G23758-002 G23758-002 This document provides instructions for installing the following accessory kit: FUP4X35HSDK
SERVICE GUIDE. Gateway Notebook
SERVICE GUIDE Gateway Notebook Contents Replacing Gateway Notebook Components...................................1 Identifying the notebook model......................................... 2 Identifying
HP 22-in-1 Media Card Reader
HP 22-in-1 Media Card Reader Introduction This document describes how to install the HP 22-in-1 Media Card Reader into an HP Workstations adapter bracket, and then install the media card reader and bracket
PRIMERGY BX620 S6 Server Blade
Options Guide - English PRIMERGY BX620 S6 Server Blade Options Guide August 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your
Quick Setup Guide. Tandberg Data DPS1000 Series Model: DPS1100 and DPS1200, Release: 1.3
Quick Setup Guide Tandberg Data DPS1000 Series Model: DPS1100 and DPS1200, Release: 1.3 DPS1000 Series is a data protection solution that enables Internet Small Computer System Interface (iscsi) desktop
Tyan Computer. Transport PX22. Service Engineer s Manual
Tyan Computer Transport PX22 Service Engineer s Manual 1 Precaution To read through the user manual, check all assembly and follow setup process before any operation on this server To keep paper clips,
HP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
Serial ATA to Serial ATA
Serial ATA to Serial ATA Model: MRK-300ST-BK Aluminum Mobile Rack 3-1 3-1 Introduction... 3-3 Mobile Rack Features... 3-3 Unpacking Your Mobile Rack... 3-4 IDE Basics... 3-4 3-2 Hardware Installation...
How To Configure Your Computer With A Microsoft X86 V3.2 (X86) And X86 (Xo) (Xos) (Powerbook) (For Microsoft) (Microsoft) And Zilog (X
System Configuration and Order-information Guide RX00 S4 February 008 Front View CD-ROM Drive (Optional) Hard Disk Bay Back View PCI Slot 0/00/000BASE-T connector Serial Port Display Mouse Keyboard Inside
Front Panel Board Cable Replacement Instructions
apple Mac Pro Front Panel Board Cable Replacement Instructions First Steps 1 Shut down computer. Note: Follow these instructions carefully. Failure to do so could damage your equipment and void its warranty.
Hydra esata. 4-Bay RAID Storage Enclosure. User Manual January 16, 2009 - v1.0
4-Bay RAID Storage Enclosure User Manual January 16, 2009 - v1.0 EN Table of Contents 1 Introduction... 1 1.1 System Requirements... 1 1.1.1 PC Requirements... 1 1.1.2 Mac Requirements... 1 1.1.3 Supported
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
HP 16/18-Port Cable Management Kit Installation Guide
HP 16/18-Port Cable Management Kit Installation Guide Abstract This document describes how to attach the HP 16 Port or 18 Port Cable Management Kit to an HP rack. The cable management bracket is designed
BladeRunner 4U Blade Server User Manual. December 2004 (Revision A)
BladeRunner 4U Blade Server User Manual December 2004 (Revision A) Copyright Notice The copyright in all material provided in this User Manual is held by Penguin Computing Inc. or by the original creator
Replacement Instructions. Warning: During this procedure, keep small parts away from children.
apple Power Mac G4 / Macintosh Server G4 ATA Hard Drive Replacement Instructions Follow the instructions in this sheet carefully. Failure to follow these instructions could damage your equipment and void
GPS AutoSteer System Installation Manual
GPS AutoSteer System Installation Manual Supported Vehicles John Deere Sprayers 4720 4630 4730 4830 AutoTrac Ready PN: 602-0227-01-A LEGAL DISCLAIMER Note: Read and follow ALL instructions in this manual
PS6500 Storage Arrays Rack Mount Instructions
PS6500 Storage Arrays Rack Mount Instructions Part Number: R724M Rev. A01 Copyright 2010 Dell, Inc. All rights reserved. Dell is a trademark of Dell, Inc. EqualLogic is a registered trademark. All trademarks
PCI-to-SATA RAID Adapter AEC-6890M. User s Manual Version:1.0
PCI-to-SATA RAID Adapter AEC-6890M User s Manual Version:1.0 Copyright 2003 ACARD Technology Corp. Release: August 2003 Copyright and Trademarks The information of the product in this manual is subject
Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2 www.akitio.
Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives User Manual March 31, 2014 v1.2 www.akitio.com EN Table of Contents Table of Contents 1 Introduction... 1 1.1 Technical Specifications...
Processor Cage Fans, Front and Rear Replacement Instructions
apple Mac Pro Processor Cage Fans, Front and Rear Replacement Instructions First Steps 1 Shut down computer. Note: Follow these instructions carefully. Failure to do so could damage your equipment and
Installation Guide. Wyse C Class Conversion to WES7. Wyse USB Firmware Tool TM Release 1.10. Issue: 102910 PN: 883887-17L Rev. B
Installation Guide Wyse C Class Conversion to WES7 Wyse USB Firmware Tool TM Release 1.10 Issue: 102910 PN: 883887-17L Rev. B Copyright Notices 2010, Wyse Technology Inc. All rights reserved. This manual
EasyNote TJ Series. Disassembly Manual
EasyNote TJ Series Disassembly Manual CHAPTER3 Replacing notebook components Preventing static electricity discharge Preparing the work space Required tools Preparing the notebook Adding or replacing memory
16/32 Channel 1U Rack Mount CCTV Power Supply
16/32 Channel 1U Rack Mount CCTV Power Supply Manual PH-A3224-GUQ Shown 16-Channel 32-Channel PTC PH-A1612-PUQ PH-A3224-PUQ Glass Fuse PH-A1612-GUQ PH-A3224-GUQ Industrial design 12 Amp 3 Amps per channel
Manual OS Installation
CA92276-8158 EN-09 ECONEL 100 S2 / TX120 / TX150 S6 / TX300 S4 / RX100 S5 / RX200 S4 / RX300 S4 / RX600 S4 Manual OS Installation Before Reading This Manual Before Reading This Manual Remarks Symbols Symbols
Rack Mount Kit Install Guide: Intel Entry Server Chassis SC5295-E UP/DP/WS/BRP Intel Entry Server Chassis SC5299-E DP/WS/BRP
Rack Mount Kit Install Guide: Intel Entry Server Chassis SC5295-E UP/DP/WS/BRP Intel Entry Server Chassis SC5299-E DP/WS/BRP A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products
Removable 2.5 SATA HDD Backup System
Removable 2.5 SATA HDD Backup System SAT2510U3REM SAT2510U3S *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario
NOTE: Additional user information for your printer may be available in the "Manuals" section at support.dell.com.
CAUTION: General Safety Instructions Use the following safety guidelines to help ensure your own personal safety and to help protect your equipment and working environment from potential damage. NOTE:
IDE ATA/133 Controller
IDE ATA/133 Controller 2 Port PCI ATA-133 IDE Adapter Card PCIIDE2 Actual product may vary from photo FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class
Installation Guide. Wyse D Class 4-GB RAM Upgrade Option Kit. Products: D90D7, D90DW. Issue: 121312 PN: 883884-35L Rev. A
Installation Guide Wyse D Class 4-GB RAM Upgrade Option Kit Products: D90D7, D90DW Issue: 121312 PN: 883884-35L Rev. A Copyright Notices 2012, Wyse Technology Inc. All rights reserved. This manual and
UPLIFT Height Adjustable Standing Desk (T-Frame) DIRECTIONS FOR ASSEMBLY AND USE - - ALSO - - Watch our assembly video
UPLIFT Height Adjustable Standing Desk (T-Frame) DIRECTIONS FOR ASSEMBLY AND USE - - ALSO - - Watch our assembly video http://bit.ly/9ywwh! CAUTION MAKE SURE NO OBSTACLES ARE IN THE DESK S PATH AND ALL
Dell Inspiron 660s Owner s Manual
Dell Inspiron 660s Owner s Manual Computer model: Inspiron 660s Regulatory model: D06S Regulatory type: D06S001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you
Wall-Mounting your HP computer. User Guide
Wall-Mounting your HP computer User Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should
Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE
Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards 1.2 PACKAGE
Hard Disk Drive (HDD)
Installation Instructions Hard Disk Drive (HDD) Catalog Number 6189V-35HDDST80, 6189V-35HDDST160 Topic Page About This Publication 1 Important User Information 2 Electrostatic Discharge (ESD) Precautions
SNQ-60x0-320 Series Data Center Switch. Quick Installation Guide
Introduction This guide is to assist the reader with the most basic form of installation and connection to switches in this series. As there is more than one switch in this series, the diagrams might slightly
Rail Kit Install Guide: Intel Modular Server System MFSYS25 A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products
Rail Kit Install Guide: Intel Modular Server System MFSYS25 A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products Intel Order Number: E12567-002 Disclaimer Information
System Board D2779 for PRIMERGY TX100 S2
Technical Manual - English System Board D2779 for PRIMERGY TX100 S2 Technical Manual Edition June 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion
430 Power/Electronics Replacement
Replacing the main board WARNING Before proceeding, turn off the main power switch and unplug the power cord. Caution Make sure you are properly grounded with an ESD strap before continuing. The main printed
Installation Guide. Wyse C Class 2-GB RAM Upgrade Option Kit. Issue: 092910 PN: 883884-13L Rev. A
Installation Guide Wyse C Class 2-GB RAM Upgrade Option Kit Issue: 092910 PN: 883884-13L Rev. A Copyright Notices 2010, Wyse Technology Inc. All rights reserved. This manual and the software and firmware
Installing the Video Input and TV Tuner Cards in a Compact Computer or a Dual PCI-Slot Tower Computer
Installing the Video Input and TV Tuner Cards in a Compact Computer or a Dual PCI-Slot Tower Computer This booklet describes how to install the video input and TV tuner cards in a compact Macintosh computer
Installation Guide. Wyse VX0L and VX0LE Thin Clients 1-GB RAM Upgrade Option Kit. Issue: 022808 PN: 883884-07L Rev. A
Installation Guide Wyse VX0L and VX0LE Thin Clients 1-GB RAM Upgrade Option Kit Issue: 022808 PN: 883884-07L Rev. A ii Copyright Notice 2008, Wyse Technology Inc. All rights reserved. This manual and the
How To Install A Power Supply (Uplast) With A Battery Pack
APC Smart-UPS RT SURTA48XLBP/SURTA48XLBPJ External Battery Pack User Manual Introduction/Before Installation About this Manual The APC Smart-UPS RT external battery pack (SURTA48XLBP or SURTA48XLBPJ) connects
Building A Computer: A Beginners Guide
Building A Computer: A Beginners Guide Mr. Marty Brandl The following was written to help an individual setup a Pentium 133 system using an ASUS P/I- P55T2P4 motherboard. The tutorial includes the installation
Replacement Instructions. Warning: During this procedure, keep small parts away from children.
apple ibook G4 Memory Card Replacement Instructions Follow the instructions in this sheet carefully. Failure to follow these instructions could damage your equipment and void its warranty. Note: Written
PRIMERGY RX300 S6 Server
Service Supplement - english PRIMERGY RX300 S6 Server Service Supplement Edition March 2010 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual.
Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009
Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide Version 8.2 March 2009 Trademarks Riverbed, the Riverbed logo, Riverbed Cascade, and Cascade are trademarks of Riverbed Technology,
Multi-function Front Panel USB2.0/Firewire 400/eSATA
Multi-function Front Panel USB2.0/Firewire 400/eSATA Model No.: UGT-IH100 Installation Guide v1.01 1 Prescribed Use The UGT-IH100 is designed to be installed into the 3.5 or 5.25 plug-in unit of a computer
DE1600 DSA E-Series iscsi Disk Arrays. Installation Manual
DE1600 DSA E-Series iscsi Disk Arrays en Installation Manual DE1600 DSA E-Series iscsi Disk Arrays Table of Contents en 3 Table of Contents 1 Safety Precautions 4 1.1 Warning Notices 4 1.2 Caution Notices
=============================== WARNING
=============================== WARNING EXPLANATION OF GRAPHICAL SYMBOLS This symbol is intended to alert the user to the presence of unprotected dangerous voltage" within the product's enclosure that
Memory Installation Guide
Memory Installation Guide For ASUSTOR 6 Series NAS Ver.1.0.0.1204 Table of Contents 1. Introduction... 3 1.1. Notes and Precautions... 3 1.2. Parts and Tools Needed... 4 2. Installation Guide... 5 2.1.
Manual IB-3620 Series
IB-RD3620SU3 1 IB-3620U3 CONTENT 1. Introduction... 3 1.1 General Information... 3 2. Hardware IB-3620 Series... 4 2.1 LED Indication / Button Front Panel... 4 2.2 Rear View... 5 3. HDD Installation...
Intel RAID Module RMS3CC080/ RMS3CC040 and Intel RAID Maintenance Free Backup Unit 5 Quick Installation User's Guide
Intel RAID Module RMS3CC080/ RMS3CC040 and Intel RAID Maintenance Free Backup Unit 5 Quick Installation User's Guide Thank you for buying an Intel RAID Module. Your Intel RAID Module provides reliability,
PCI/PXI ETHERNET ADAPTERS
INSTALLATION GUIDE PCI/PXI ETHERNET ADAPTERS Installing Your PCI Board National Instruments offers several Ethernet adapters based on the Intel 82559-compatible Ethernet controller. This document explains
esata External Storage
esata External Storage Operation Manual DA-ES110 Before reading this manual This operation manual contains basic instruction on installing and using esata External Storage, an IDIS product. Users who are
PRIMERGY TX200 S4. Operating manual
PRIMERGY TX200 S4 Operating manual Edition March 2008 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize
Contents. Installing the upgrade memory kit in the G450 and G430 Media Gateway May 2014 1
Contents Installing the upgrade memory kit in the G450 / G430 Media Gateway... 3 Equipment ordering... 3 Inserting or replacing a RAM card... 4 Inserting or replacing a RAM card in the G450... 4 Replacing
Chapter 5 Cubix XP4 Blade Server
Chapter 5 Cubix XP4 Blade Server Introduction Cubix designed the XP4 Blade Server to fit inside a BladeStation enclosure. The Blade Server features one or two Intel Pentium 4 Xeon processors, the Intel
TRIMBLE TX5 3D LASER SCANNER QUICK START GUIDE
TRIMBLE TX5 3D LASER SCANNER QUICK START GUIDE Equipment 1 8 9 5 6 7 4 3 2 The TX5 laser scanner ships with the following equipment: 1 Scanner transport and carry case 6 USB memory card reader 2 AC power
Rack installation instructions
Rack installation instructions Review the documentation that comes with the rack cabinet for safety and cabling information. Before you install the server in a rack cabinet, review the following guidelines:
Intel NUC Kit DC3217IYE User Guide. Intel NUC Kit DC3217IYE
Intel NUC Kit DC3217IYE User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers and with the safety practices
easyraid Q12 Hardware User Manual
easyraid Q12 Hardware User Manual Ultra 320 SCSI to Serial ATA & Fibre Channel to Serial ATA Disk Array Systems Version 1.0 easyraid Q12-U4R2 Ultra 320 SCSI to Serial ATA Disk Array System & easyraid Q12-F2R2
Replacing the Gateway M320 Keyboard
Replacing the Gateway M320 Keyboard This package includes a replacement keyboard for your Gateway M320 notebook and these printed instructions. Tools you need You need a small Phillips and a small flat-blade
QNAP RAID Expansion Enclosure Hardware User Manual. 2014. QNAP Systems, Inc. All Rights Reserved.
QNAP RAID Expansion Enclosure Hardware User Manual 2014. QNAP Systems, Inc. All Rights Reserved. Thank you for choosing QNAP products! This user manual provides descriptions of the hardware of the QNAP
About the BitStorm 6051 POTS Splitter
BitStorm 6051 Installation Instructions Document Number 6051-A2-GZ40-10 July 2002 About the BitStorm 6051 The BitStorm system enables simultaneous high-speed digital data access and analog voice service
SATA PCI Express Adapter PEXSATA22I
SATA PCI Express Adapter PEXSATA22I FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These
How To Use An Nc Express5800 Card (Nec) With A Remote Management Card (Ec) On A Pc Or Mac Computer (Nemca) With An Ipa/Sda/Sdu) On An Ipad Or
Remote Management Card User s Guide 07/2004 8115-01_RMC CONTENTS Safety Indications... 3 About Remote Management Card... 4 Components... 4 Installation / Removal / Replacement... 5 Installation... 6 Removal...
Removing memory and option cards
These instructions can help you remove memory or option cards. Use the following illustration to locate the connector for the card you want to remove. Hard disk connector 1 Option card connector Firmware
BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability. Quick Start Guide NOTES
NOTES BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability Quick Start Guide This is a Class A device and is not intended for use in a residential environment. Important
FUSION R400 RAID USB 3.0
FUSION R400 RAID USB 3.0 1U Rackmount 4-Drive Hardware RAID 5 SATA Storage System with USB 3.0 Interface User s Guide For Windows Contents 1 Fusion R400 RAID USB 3.0 Features 1 2 Drive Installation and
TeamPoS 2000 Installation Instructions Upgrade to M Motherboard
TeamPoS 2000 Installation Instructions Upgrade to M Motherboard Fujitsu Transaction Solutions Inc. endeavors to ensure that the information in this document is correct and fairly stated but does not accept
Installation Guide. Wyse Z Class 2 and 4-GB RAM Upgrade Option Kit. Products: Z90DW, Z90SW, Z90D7, Z90S7. Issue: 122211 PN: 883884-32L Rev.
Installation Guide Wyse Z Class 2 and 4-GB RAM Upgrade Option Kit Products: Z90DW, Z90SW, Z90D7, Z90S7 Issue: 122211 PN: 883884-32L Rev. A Copyright Notices 2011, Wyse Technology Inc. All rights reserved.
HP Optical Bay Hard Drive Bracket
HP Optical Bay Hard Drive Bracket Introduction This document describes how to install 8.89 cm (3.5 inch) hard drives in the HP optical bay hard drive bracket and install the bracket in the optical drive
Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide
Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide Thank you for buying an Intel RAID Maintenance Free Backup Unit 4. The Intel RAID Maintenance Free Backup Unit 4 supports the Intel
PCS300 Universal IP Reporting Module V1.0
PCS300 Universal IP Reporting Module V1.0 Reference and Installation Manual Patents: One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259, 5886632, 5721542, 5287111,
SATA II-150 PCI Quick Installation Guide
SATA II-150 PCI Quick Installation Guide Introducing the SATA II-150 PCI The SATA II-150 PCI is an ultra high-speed dual channel Serial ATA Generation 2 controller for use in PCI enabled systems. Features
Changing the SIM in a BANDIT Product s GSM Card
encor! enetworks TM Version A.2, January 2013 2013 Encore Networks, Inc. All rights reserved. Changing the SIM in a BANDIT Product s GSM Card Wireless connections use radiofrequencies (RFs) through airwaves
Serial ATA PCI Quick Installation Guide
Serial ATA PCI Quick Installation Guide Introducing the Serial ATA PCI The Serial ATA PCI is an ultra high-speed dual channel Serial ATA controller board for use in Pentium-class computers. It achieves
EVGA Z97 Classified Specs and Initial Installation (Part 1)
User Guide EVGA Z97 Classified Specs and Initial Installation (Part 1) - 1 - Table of Contents Before you Begin 3 Parts Not in the kit.4 Intentions of the kit 4 Motherboard Specifications 5 Unpacking and
HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide
HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide HP Part Number: 574412-doc Published: May 2009 Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein
HP AD397A rx2660 SAS Smart Array P400 Controller Installation Guide Manufacturing Part Number: AD397-9001A February 2007
HP AD397A rx2660 SAS Smart Array P400 Controller Installation Guide Manufacturing Part Number: AD397-9001A February 2007 United States Copyright 2007 Hewlett-Packard Development Company L.P.. Legal Notices
Set Up Your MXI -Express x4 System
Set Up Your MXI -Express x4 System Terminology This document explains what you will need to set up various MXI-Express x4 hardware configurations. The products covered by this guide are the NI PCIe-8371/8372