HP AD397A rx2660 SAS Smart Array P400 Controller Installation Guide Manufacturing Part Number: AD A February 2007

Size: px
Start display at page:

Download "HP AD397A rx2660 SAS Smart Array P400 Controller Installation Guide Manufacturing Part Number: AD397-9001A February 2007"

Transcription

1 HP AD397A rx2660 SAS Smart Array P400 Controller Installation Guide Manufacturing Part Number: AD A February 2007 United States Copyright 2007 Hewlett-Packard Development Company L.P..

2 Legal Notices The information in this document is subject to change without notice. Hewlett-Packard makes no warranty of any kind with regard to this manual, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be held liable for errors contained herein or direct, indirect, special, incidental or consequential damages in connection with the furnishing, performance, or use of this material. Warranty A copy of the specific warranty terms applicable to your Hewlett-Packard product and replacement parts can be obtained from your local Sales and Service Office. U.S. Government License Proprietary computer software. Valid license from HP required for possession, use or copying. Consistent with FAR and , Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. Copyright Notice Copyright 2007 Hewlett-Packard Development Company L.P. All rights reserved. Reproduction, adaptation, or translation of this document without prior written permission is prohibited, except as allowed under the copyright laws. Trademark Notices UNIX is a registered trademark in the United States and other countries, licensed exclusively through The Open Group Localized Documentation This Installation Guide has been translated to: 2

3 Contents 1. Installing the SAS Smart Array P400 Controller Overview of Installation Steps Installing the Smart Array Controller Power Off the Server Extending the Server from the Rack Removing the Top Cover Removing the I/O Backplane Card Cage from the Server Installing the SAS Smart Array and PCI-e Expansion Cards Installing the Smart Array P400 Controller Battery Replacing the I/O Backplane Card Cage Replacing the Top Cover Checking and Updating Smart Array P400 Controller Firmware Checking the Controller Firmware Downloading the Firmware Update, If Needed Updating the Controller Firmware HELP or? Error Messages Creating Logical Drives ORCA Utility Creating a Logical Drive Using ORCA A. Smart Array P400 Controller Overview Board Components and Features Controller Board Runtime LEDs Battery Pack LEDs Supported Drive Types B. Fault Management Fault Management Features Fault Management in Supported RAID Configurations C. Declaration of Conformity 3

4 Contents 4

5 1 Installing the SAS Smart Array P400 Controller This chapter provides information to help you plan the installation and configuration of each Smart Array Controller. This chapter addresses the following topics: Overview of Installation Steps on page 5 Installing the Smart Array Controller on page 6 Checking and Updating Smart Array P400 Controller Firmware on page 15 Creating Logical Drives on page 19 Overview of Installation Steps Complete Smart Array documentation (including the HP Smart Array RAID Controllers Support Matrix) is available at: To view a detailed list of support accessories visit the system configuration site at: Following is a summary of the steps to install your Smart Array Series Controller: Step 1. Plan your disk configurations. See RAID Technology Overview in the HP Smart Array P400 Support Guide, available at: Step 2. Verify that you have all of the components of the upgrade kit: Table 1-1 HP AD397A Smart Array P400 Controller Option Kit Components Part Number Description Smart Array P400 Controller AB PCI-e Expansion Card Smart Array P400 controller cache module, 256 MB Smart Array P400 controller battery charger module Smart Array P400 controller battery cable assembly, 11.5-in Step 3. Install the controller. See Installing the Smart Array Controller on page 6. Step 4. Check the controller firmware version, and upgrade or downgrade the firmware if necessary. See Checking and Updating Smart Array P400 Controller Firmware on page 15. Step 5. Create one or more logical drives. Chapter 1 5

6 Installing the SAS Smart Array P400 Controller Installing the Smart Array Controller Installing the Smart Array Controller The rx2660 server has two slots dedicated for the SAS Smart Array P400 controller and PCI-e expansion card. Use these procedures to install these cards on the system board. Here are the high level procedures to install the SAS Smart Array card and the PCI-e expansion card: Power off the server Remove external LAN and power cables from the server Extend the server from the rack Remove the top access cover Remove the I/O backplane assembly Install the SAS Smart Array P400 controller card Install the PCI-e expansion card Install the P400 controller battery Reroute the SAS cables from the system board to the P400 controller card Install the I/O backplane assembly Install the top access cover Push the server into the rack Connect external LAN and power cables Power on the server Power Off the Server Power off the server using the following methods if the server is in the standby or full power state: ilo MP PC command Power button Powering Off the Server Using the ilo MP To power off the server using the ilo MP, follow these steps: Step 1. Gracefully shut down the operating system. Step 2. Initiate a console session, and access the MP Main Menu. Step 3. Enter CM to enable command mode. Step 4. Enter PC to use the remote power control command. Step 5. Enter OFF to power off the server, and enter YES when prompted to confirm the action. CAUTION The main DC voltage is now removed from the system; however, AC voltage for standby power is still present in the server. Step 6. Unplug all power cables from the receptacles on the rear panel of the server. 6 Chapter 1

7 Installing the SAS Smart Array P400 Controller Installing the Smart Array Controller Powering Off the Server Manually To manually power off the server, follow these steps: Step 1. Gracefully shut down the operating system. Step 2. Press the power button to power off the server. CAUTION The main DC voltage is now removed from the system; however, AC voltage for standby power is still present in the server. Step 3. Unplug all power cables from the receptacles on the rear panel of the server. Extending the Server from the Rack NOTE Ensure that there is enough area (approximately 1.5 meters [4.5 ft.]) to fully extend the server from the front of the rack to work on it. To extend the server from the rack, follow these steps: Step 1. Flip out the two pull handles located on both ends of the front bezel. This allows the server to slide out of the rack. Step 2. Slowly pull the server forward by the handles until it is fully extended. NOTE The server is fully extended when the rail clips are locked in place and the top cover is completely accessible. Figure 1-1 Extending the Server from the Rack Flip handle down to slide the server out of the rack Flip handle down to slide the server out of the rack Chapter 1 7

8 Installing the SAS Smart Array P400 Controller Installing the Smart Array Controller Removing the Top Cover When installing internal components into the server, you must first remove the top cover. To remove the top cover, follow these steps: Step 1. Unlock the cover release lever (if necessary) by turning the cam approximately 90 degrees counterclockwise with the allen wrench provided on the rear panel of the server (1). Step 2. Pull up on the cover release lever to disengage the top cover from the chassis (2). See Figure 1-2. Figure 1-2 Removing the Top Cover Step 3. Slide the cover toward the rear of the server until the tabs release from the slots in the chassis (3). Step 4. Lift the cover off the chassis (4). Removing the I/O Backplane Card Cage from the Server To access the SAS cables in your server, you must first remove the I/O backplane card cage from the system board. To remove the I/O backplane card cage, follow these steps: Step 1. Loosen the two captive screws. Follow these steps to loosen the captive screws: a. Press the blue button to release the black knob. See Figure 1-3. b. Turn the black knob counterclockwise until the captive screw is free from the server. 8 Chapter 1

9 Installing the SAS Smart Array P400 Controller Installing the Smart Array Controller Figure 1-3 Removing the I/O Backplane Card Cage Captive screws Front of server Step 2. Lift the assembly straight up and out of the server. Step 3. Disconnect the SAS cables connected to the system board, and remove the cables from the two routing clips on the server chassis. See Figure 1-4. Step 4. Route the cables through the unused clip against the server chassis back panel. Figure 1-4 SAS Cables Connected to the System Board B A Integrated SAS cable-routing clips Clip for new SAS cable routing Chapter 1 9

10 Installing the SAS Smart Array P400 Controller Installing the Smart Array Controller Step 5. Check that the cables are routed around the I/O backplane card cage connector, so that they will not be pinched when the backplane assembly is re-installed. Figure 1-5 SAS Cables Connected to the System Board SAS cable routed around I/O backplane card cage connector Installing the SAS Smart Array and PCI-e Expansion Cards The rx2660 server has two slots dedicated for the SAS Smart Array P400 controller and PCI-e expansion cards. If you purchase the RAID option, you must install these cards on the system board. See Figure 1-6 for the slot locations on the system board. Installing the PCI-e Expansion Card To install the PCI-e expansion card into the server, follow these steps: Step 1. Pinch the card locking guides to expose the slot guides to the system board slot (1). See Figure 1-6. Step 2. Guide the PCI-e expansion board down the rails and push into the slot on the system board (2). NOTE The board and slot are keyed, so the board only fits one way into the slot. 10 Chapter 1

11 Installing the SAS Smart Array P400 Controller Installing the Smart Array Controller Figure 1-6 SAS Smart Array P400 Controller and PCI-e Expansion Board Slots Card locking guides PCI-e expansion card (in slot) Front of server SAS smart array P400 controller card slot Step 3. Close the board locking guides to lock the PCI-e expansion card into place on the system board. Installing the SAS Smart Array P400 Controller Card To install the SAS Smart Array P400 controller card into the server, follow these steps: Step 1. Install the 256 Mb memory card to the P400 controller card by snapping it into place. See Figure 1-7. Step 2. Open the blue SAS Smart Array P400 controller board lock on the rear panel of the server. Chapter 1 11

12 Installing the SAS Smart Array P400 Controller Installing the Smart Array Controller Figure 1-7 SAS Ports on the Smart Array P400 Controller Board Memory card installed on P400 controller card B A SAS ports on the SAS Smart Array P400 controller card SAS Smart Array P400 controller card Card lock (open) Step 3. Install the SAS Smart Array P400 controller card into the slot on the system board as shown in Figure 1-7. Step 4. Close the board lock over the tab on the SAS Smart Array P400 controller card and snap it shut. Step 5. Attach the SAS cables to the SAS Smart Array P400 controller card. The SAS cables are clearly marked A and B. Ensure they match up with the ports on the P400 controller card shown in Figure 1-7. CAUTION When connecting the SAS cables, match each cable with the appropriate socket on the SAS Smart Array P400 controller card. If the cables are mismatched, the server may not reboot. Both cables and sockets are clearly marked with the correct channels. Installing the Smart Array P400 Controller Battery Use these procedures to install the Smart Array P400 Controller battery. Step 1. To install the P400 controller battery onto the airflow guide, follow these steps: 12 Chapter 1

13 Installing the SAS Smart Array P400 Controller Installing the Smart Array Controller a. Align the tabs on the P400 controller battery with the slots on the airflow guide. b. Slide the P400 controller battery toward the rear of the server until the locking clip locks the P400 controller battery in place. Figure 1-8 Installing the RAID battery 1 Battery cable plugged into battery Step 2. Plug the battery cable into the battery. See Figure 1-8. Step 3. Plug the battery cable into the P400 controller card. See Figure 1-9. Figure 1-9 Battery Cable Port on the P400 Controller Card Battery cable plugged into the P400 controller card Chapter 1 13

14 Installing the SAS Smart Array P400 Controller Installing the Smart Array Controller Replacing the I/O Backplane Card Cage To replace the I/O backplane card cage into the server, follow these steps: Step 1. Align the tabs with the guide slots in the server and slide the I/O backplane assembly into place. See Figure 1-3. NOTE Ensure the I/O backplane card cage is fully seated into the server. If the I/O backplane card cage is not fully seated, the server may not boot. Ensure the SAS cables are not pinched under the I/O backplane card cage when installing it into the server. The SAS cables should be routed to the right of the I/O backplane card cage. Step 2. Tighten the two captive screws. a. Press the black knob down while turning it clockwise until it is fully tightened. b. While holding the black knob and pressing down, press and release the blue button to lower the black knob to the locked position. Replacing the Top Cover To replace the top cover, follow these steps: Step 1. Ensure the cover release lever is in the open position. See Figure Step 2. Align the tabs of the top cover with the corresponding slots in the chassis and insert the tabs into the slots (1). Step 3. Slide the cover forward until it is flush with the front of the chassis (2). Step 4. Push the cover release lever down into the latched position (3). Step 5. Lock the cover release lever (if necessary) by turning the cam approximately 90 degrees clockwise. Figure 1-10 Replacing the Top Cover Chapter 1

15 Installing the SAS Smart Array P400 Controller Checking and Updating Smart Array P400 Controller Firmware Checking and Updating Smart Array P400 Controller Firmware Follow the procedures in this section to verify that the correct adapter firmware version is installed before you attempt to boot the server. Firmware version requirements are found in the HP Smart Array RAID Controllers Support Matrix in the Smart Array (RAID) section of: WARNING The HP Smart Array P400 Controller Option has specific adapter firmware version requirements for use in HP Integrity servers. If you use any other firmware version, data loss may occur. Follow the steps in this section to ensure that the correct firmware version is installed. Checking the Controller Firmware Use saupdate from the EFI Shell to update the firmware image on the HP Smart Array P400. Follow one of these two procedures to run saupdate: If you are using saupdate from the Offline Diagnostic CD: Step 1. Place the Offline Diagnostic CD containing saupdate.efi in the CD drive before booting the system. Step 2. Boot the system to the EFI Shell prompt. Step 3. Locate the cdrom entry in the list of mapped devices, and change to the device by typing its associated fs number (for example, fs0) under EFI Shell prompt. Step 4. If the EFI utility is not located in the root directory, move to the directory in which the file is located, for example: fs0:\>cd \EFI\HP\TOOLS\IO_CARDS\SmartArray If you are not using the Offline Diagnostic CD: Step 1. Download the SA EFI update utility saupdate.efi and copy it to the EFI partition. Step 2. Boot the system to the EFI Shell and change directories to the EFI partition. Step 3. If the EFI utility is not located in the root directory, move to the directory in which the file is located, for example: fs0:\>cd \EFI\HP\TOOLS\IO_CARDS\SmartArray Run saupdate.efi using the using the fs0:\> saupdate.efi command. Use saupdate LIST to display all detected Smart Array controllers along with the active firmware versions: Chapter 1 15

16 Installing the SAS Smart Array P400 Controller Checking and Updating Smart Array P400 Controller Firmware fs0:\efi\tools> saupdate list ******************************************************************************** Smart Array Offline Firmware Update Utility Version (C) Copyright 2006 Hewlett-Packard Development Company, L.P. ******************************************************************************** Seg Bus Dev Func Description Version HP Smart Array P In this example, the system contains one Smart Array P400 Controller at at segment 0, bus 52, device 0, function 0, running firmware version Compare this to the minimum recommended firmware version found in the HP Smart Array RAID Controllers Support Matrix in the Smart Array (RAID) section of: If the controller firmware meets the minimum recommended version, no further action is necessary. Downloading the Firmware Update, If Needed To locate and download firmware for the Smart Array P400 Controller, follow these steps: Step 1. Go to the Business Support Center at: Step 2. Search for Smart Array P400. Step 3. In the Narrow search using only: section, click Drivers and software. Step 4. Locate and click the link for the firmware download package. Step 5. Review the installation instructions and release notes on the download page. Step 6. Download the firmware. HP recommends that you follow the procedures supplied with the update package to install the firmware update. Updating the Controller Firmware NOTE This section contains a generic procedure to update firmware from the EFI shell. HP recommends that you follow the procedures supplied with the update package to install the firmware update. Use saupdate from the EFI Shell to update the firmware image on the HP Smart Array P400. Follow one of these two procedures to run saupdate: If you are using saupdate from the Offline Diagnostic CD: Step 1. Download the firmware and copy it to the EFI partition. Step 2. Place the Offline Diagnostic CD containing saupdate.efi in the CD drive before booting the system. Step 3. Boot the system to the EFI Shell prompt. 16 Chapter 1

17 Installing the SAS Smart Array P400 Controller Checking and Updating Smart Array P400 Controller Firmware Step 4. Locate the cdrom entry in the list of mapped devices, and change to the device by typing its associated fs number (for example, fs0) under EFI Shell prompt. Step 5. If the EFI utility and firmware image files are not located in the root directory, move to the directory in which these files are located, for example: fs0:\>cd \EFI\HP\TOOLS\IO_CARDS\SmartArray IMPORTANT Both saupdate.efi and the firmware image file must be located in the same directory. If they are not, copy them both to the EFI partition. Run the saupdate.efi using the fs0:\> saupdate command. If you are not using the Offline Diagnostic CD: Step 1. Download the SA EFI update utility saupdate.efi and copy it to the EFI partition. Step 2. Download the firmware and copy it to the EFI partition. Step 3. Boot the system to the EFI Shell and change directories to the EFI partition. When you are ready to run saupdate, use saupdate UPDATE to update the firmware on the Smart Array P400 Controller. The syntax of the saupdate UPDATE command is as follows: saupdate UPDATE [<seg:bus:dev:func>] [smartarray_firmware_file] For example, to update the controller at segment 0, bus 52, device 0, function 0 from the example output above: fs0:\> saupdate UPDATE 0:52:0:0 SPAWNxxxyyy.PAK Replace SPAWNxxxyyy.PAK with the name of your firmware file. For example: fs0:\efi\tools> saupdate update 0:52:0:0 SPAWN PAK ******************************************************************************** Smart Array Offline Firmware Update Utility Version (C) Copyright 2006 Hewlett-Packard Development Company, L.P. ******************************************************************************** Updating controller in Seg: 0, Bus: 52, Dev: 0, Func: 0 Current firmware version 2.06 Percentage completed: 100% Activating firmware now, this may take several minutes. Resetting and reinitializing controller. Retrieving firmware version, this may take several minutes. Current controller firmware version is Chapter 1 17

18 Installing the SAS Smart Array P400 Controller Checking and Updating Smart Array P400 Controller Firmware Verifying the Firmware Update After updating the firmware, cycle the power on the system and on any external JBODS connected to the system. After performing the firmware update, use LIST to confirm that the correct firmware version is installed; see Checking the Controller Firmware on page 15. For example: fs0:\efi\tools> saupdate list ******************************************************************************** Smart Array Offline Firmware Update Utility Version (C) Copyright 2006 Hewlett-Packard Development Company, L.P. ******************************************************************************** Seg Bus Dev Func Description Version HP Smart Array P HELP or? Use HELP or? to display usage text, program version number, and build date: Enter: saupdate HELP or saupdate? Error Messages The following error messages may appear when using the saupdate utility: When keyword LIST or UPDATE is misspelled or extra parameters are specified: Error: Syntax Error Usage: saupdate LIST or saupdate UPDATE [ all ] When the controller ID in the saupdate UPDATE command is not correct: No matching controller found When a firmware file does not exist in the saupdate UPDATE command, the example shows: SPAWN BIN does not exist. File SPAWN BIN: Not Found When an invalid firmware or corrupted file is specified in the saupdate UPDATE command, the example shows: SPAWN BIN does not exist. File SPAWN BIN: invalid or corrupted 18 Chapter 1

19 Installing the SAS Smart Array P400 Controller Creating Logical Drives Creating Logical Drives This section describes the steps to create logical drives for a Smart Array Series Controller using the Option ROM Configuration for Arrays (ORCA) utility. ORCA Utility To use ORCA, follow these steps: Step 1. Power on the server. POST runs, and any array controllers that are in the server are initialized one at a time. During each controller initialization process, POST halts for several seconds while an ORCA prompt message displays. Step 2. At the ORCA prompt: If you are connected using a headless console, press the Esc+8 combination. Otherwise, press F8. The ORCA Main Menu displays, enabling you to create, view, or delete a logical drive. Figure 1-11 ORCA Main Menu Creating a Logical Drive Using ORCA To create a logical drive using ORCA, follow these steps: Step 1. Select Create Logical Drive. The screen displays a list of all available (unconfigured) physical drives and the valid RAID options for the system. Chapter 1 19

20 Installing the SAS Smart Array P400 Controller Creating Logical Drives Step 2. Use the Arrow keys, Spacebar, and Tab to navigate around the screen and set up the logical drive, including an online spare drive if one is required. NOTE You cannot use ORCA to configure one spare drive to be shared among several arrays. Only ACU enables you to configure shared spare drives. Step 3. Press Enter to accept the settings. Step 4. Press F8 to confirm the settings and save the new configuration. After several seconds, the Configuration Saved screen displays. Step 5. Press Enter to continue. You can now create another logical drive by repeating the previous steps. NOTE Newly created logical drives are invisible to the operating system. To make the new logical drives available for data storage, format them using the instructions given in the operating system documentation. 20 Chapter 1

21 A Smart Array P400 Controller Overview This chapter describes the board components, features, and diagnostic LEDs on the Smart Array P400 Controller. Appendix A 21

22 Smart Array P400 Controller Overview Board Components and Features Board Components and Features Two models of the HP Smart Array P400 Controller are available. One model has the internal Serial-Attached SCSI (SAS) connectors on the front of the board; see Figure A-1. The other model has the connectors on the back of the board; see Figure A-2 on page 23. The two models have identical functionality. Figure A-1 and Table A-1 illustrate the components of the Smart Array P400 Controller with connectors on the front of the board. Figure A-1 HP Smart Array P400 Controller with SAS Connectors on Front Table A-1 Item ID Components of the HP Smart Array P400 Controller with SAS Connectors on Front Description 1 SAS or SATA port 2I (internal), 4x wide SFF8484 connector. 2 SAS or SATA port 1I (internal), 4x wide SFF8484 connector. 3 Connectors for cache module (also known as BBWC or array accelerator) 4 Runtime LEDs. See Controller Board Runtime LEDs on page Cache module, with connector for the cable to the optional battery pack. The cache module must be installed on the controller before the controller is installed in a server, or the controller will not boot. Figure A-2 and Table A-2 illustrate the components of the Smart Array P400 Controller with connectors on the front of the board. 22 Appendix A

23 Smart Array P400 Controller Overview Board Components and Features Figure A-2 HP Smart Array P400 Controller with SAS Connectors on Back Table A-2 Item ID Components of the HP Smart Array P400 Controller with SAS Connectors on Back Description 1 Connectors for cache module (also known as BBWC or array accelerator) 2 SAS or SATA port 1I (internal), 4x wide SFF8484 connector. 3 Runtime LEDs. See Controller Board Runtime LEDs on page SAS or SATA port 2I (internal), 4x wide SFF8484 connector. 5 Cache module, with connector for the cable to the optional battery pack. The cache module must be installed on the controller before the controller is installed in a server, or the controller will not boot. Appendix A 23

24 Smart Array P400 Controller Overview Board Components and Features Controller Board Runtime LEDs The Smart Array P400 Controller board has eight runtime LEDs that indicate various activities and error conditions. Figure A-3 illustrates their location, and Table A-3 describes how to interpret them. Figure A-3 Smart Array P400 Controller Board Runtime LEDs Table A-3 Interpretation of Runtime LEDs LED ID Color Name LED Name and Interpretation 1 Amber CR14 Controller lockup LED. 2 Amber CR13 Disk Failure LED. A physical disk connected to the controller has failed. Check the Fault LED on each disk to identify the failed disk. 3 Green CR3 Activity LED for SAS port 2I. 4 Green CR8 Activity LED for SAS port 1I. 5 Green CR5 Command Outstanding LED. The controller is working on a command from the host driver. 6 Green CR6 Heartbeat LED. This LED blinks every 2 seconds to indicate the controller health. 7 Green CR4 Gas Pedal LED. This LED, together with item 8 (CR7), indicates the amount of controller CPU activity. See Table A-4 on page Green CR7 Idle Task LED. This LED, together with item 7 (CR4), indicates the amount of controller CPU activity. See Table A-4 on page Appendix A

25 Smart Array P400 Controller Overview Board Components and Features Table A-4 Determining the Controller CPU Activity Level LED 7 Status LED 8 Status Controller CPU Activity Level Off Blinking 0 to 25% Blinking Off 25 to 50% On Steady Off 50% to 75% On steady On Steady 75% to 100% NOTE During server power on, each runtime LED illuminates randomly until POST completes. Appendix A 25

26 Smart Array P400 Controller Overview Board Components and Features Battery Pack LEDs The battery pack has four runtime LEDs that indicate battery readiness and error conditions. Figure A-4 illustrates their location; Table A-5 and Table A-6 describe how to interpret them. Figure A-4 Smart Array P400 Battery Pack LEDs Table A-5 Battery Pack LEDs LED Color Description 1 Green System Power LED. This LED glows steadily when the system is powered up and 12 V system power is available. This power supply is used to maintain the battery charge and provide supplementary power to the cache microcontroller. 2 Green Auxiliary Power LED. This LED glows steadily when 3.3V auxiliary voltage is detected. The auxiliary voltage is used to preserve BBWC data and is available any time that the system power cords are connected to a power supply. 3 Amber Battery Health LED. To interpret the illumination patterns of this LED, see the following table. 4 BBWC Status LED. To interpret the illumination patterns of this LED, see the following table. 26 Appendix A

HP Smart Array SAS Controllers for Integrity Servers Support Guide

HP Smart Array SAS Controllers for Integrity Servers Support Guide HP Smart Array SAS Controllers for Integrity Servers Support Guide HP-UX 11i v2 and 11i v3 Abstract This document describes how to install, configure, and troubleshoot HP Smart Array SAS controllers on

More information

HP Smart Array P400 Controller User Guide

HP Smart Array P400 Controller User Guide HP Smart Array P400 Controller User Guide October 2005 (First Edition) Part Number 399716-001 Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change

More information

HP Smart Array E200 Controller User Guide

HP Smart Array E200 Controller User Guide HP Smart Array E200 Controller User Guide December 2005 (First Edition) Part Number 408556-001 Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change

More information

RAID-01 (ciss) B.11.31.1005 mass storage driver release notes, edition 2

RAID-01 (ciss) B.11.31.1005 mass storage driver release notes, edition 2 RAID-01 (ciss) B.11.31.1005 mass storage driver release notes, edition 2 HP-UX 11i v3 HP Part Number: 5991-0448_ed2 Published: August 2010 Edition: 2 Copyright 2010 Hewlett-Packard Development Company,

More information

RAID Technology Overview

RAID Technology Overview RAID Technology Overview HP Smart Array RAID Controllers HP Part Number: J6369-90050 Published: September 2007 Edition: 1 Copyright 2007 Hewlett-Packard Development Company L.P. Legal Notices Copyright

More information

HP Integrity rx2660 Server Installation Guide

HP Integrity rx2660 Server Installation Guide HP Integrity rx2660 Server Installation Guide HP Part Number: AB419-9000C Published: November 2007 Copyright 2007 Hewlett-Packard Development Company, L.P Legal Notices The information contained herein

More information

Intel Rapid Storage Technology

Intel Rapid Storage Technology Intel Rapid Storage Technology User Guide August 2011 Revision 1.0 1 Document Number: XXXXXX INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,

More information

RAID 1(+0): breaking mirrors and rebuilding drives

RAID 1(+0): breaking mirrors and rebuilding drives RAID 1(+0): breaking mirrors and rebuilding drives How to, 5 th edition Introduction... 2 Splitting a mirrored array using the Array Configuration Utility... 2 Recombining a split mirrored array using

More information

RAID EzAssist Configuration Utility Quick Configuration Guide

RAID EzAssist Configuration Utility Quick Configuration Guide RAID EzAssist Configuration Utility Quick Configuration Guide DB15-000277-00 First Edition 08P5520 Proprietary Rights Notice This document contains proprietary information of LSI Logic Corporation. The

More information

Intel Matrix Storage Manager 8.x

Intel Matrix Storage Manager 8.x Intel Matrix Storage Manager 8.x User's Manual January 2009 Revision 1.0 Document Number: XXXXXX INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,

More information

Configuring ThinkServer RAID 100 on the TS140 and TS440

Configuring ThinkServer RAID 100 on the TS140 and TS440 Configuring ThinkServer RAID 100 on the TS140 and TS440 Lenovo ThinkServer TS Series Servers Lenovo Enterprise Product Group Version 1.0 September 17, 2013 2013 Lenovo. All rights reserved. LENOVO PROVIDES

More information

DF-7506 1-to-2 SATA II RAID Box

DF-7506 1-to-2 SATA II RAID Box DF-7506 1-to-2 SATA II RAID Box Version 1.0 Table of Contents Chapter 1 Product Introduction...3 1.1 Features...3 1.1.1 Shipping Package Content...3 1.2 Front View...4 1.3 Rear View...6 1.4 Disk Drive

More information

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2 www.akitio.

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2 www.akitio. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives User Manual March 31, 2014 v1.2 www.akitio.com EN Table of Contents Table of Contents 1 Introduction... 1 1.1 Technical Specifications...

More information

HP Array Configuration Utility User Guide

HP Array Configuration Utility User Guide HP Array Configuration Utility User Guide January 2006 (First Edition) Part Number 416146-001 Copyright 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change

More information

Intel RAID Controllers

Intel RAID Controllers Intel RAID Controllers Best Practices White Paper April, 2008 Enterprise Platforms and Services Division - Marketing Revision History Date Revision Number April, 2008 1.0 Initial release. Modifications

More information

Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009

Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009 Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide Version 8.2 March 2009 Trademarks Riverbed, the Riverbed logo, Riverbed Cascade, and Cascade are trademarks of Riverbed Technology,

More information

HP A7143A RAID160 SA Controller Support Guide

HP A7143A RAID160 SA Controller Support Guide HP A7143A RAID160 SA Controller Support Guide Installation and Administration of the HP A7143A PCI 4-Channel RAID160 SA SCSI Controller HP-UX Manufacturing Part Number : J6369-90026 E0512 Printed in the

More information

HP Smart Array B110i SATA RAID Controller User Guide

HP Smart Array B110i SATA RAID Controller User Guide HP Smart Array B110i SATA RAID Controller User Guide Part Number 531480-003 March 2010 (Third Edition) Copyright 2009, 2010 Hewlett-Packard Development Company, L.P. The information contained herein is

More information

DD670, DD860, and DD890 Hardware Overview

DD670, DD860, and DD890 Hardware Overview DD670, DD860, and DD890 Hardware Overview Data Domain, Inc. 2421 Mission College Boulevard, Santa Clara, CA 95054 866-WE-DDUPE; 408-980-4800 775-0186-0001 Revision A July 14, 2010 Copyright 2010 EMC Corporation.

More information

StorTrends 3400 Hardware Guide for Onsite Support

StorTrends 3400 Hardware Guide for Onsite Support StorTrends 3400 Hardware Guide for Onsite Support MAN-3400-SS 11/21/2012 Copyright 1985-2012 American Megatrends, Inc. All rights reserved. American Megatrends, Inc. 5555 Oakbrook Parkway, Building 200

More information

Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.

Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller. Embedded MegaRAID SATA User's Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview This chapter introduces

More information

Hydra Super-S Combo. 4-Bay RAID Storage Enclosure (3.5 SATA HDD) User Manual July 29, 2009 - v1.3

Hydra Super-S Combo. 4-Bay RAID Storage Enclosure (3.5 SATA HDD) User Manual July 29, 2009 - v1.3 4-Bay RAID Storage Enclosure (3.5 SATA HDD) User Manual July 29, 2009 - v1.3 EN Introduction 1 Introduction 1.1 System Requirements 1.1.1 PC Requirements Minimum Intel Pentium III CPU 500MHz, 128MB RAM

More information

Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001

Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001 Express5800/120Ed Rack Mount Kit Installation Procedures PN: 455-01607-001 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,

More information

Models Smart Array 6402A/128 Controller 3X-KZPEC-BF Smart Array 6404A/256 two 2 channel Controllers

Models Smart Array 6402A/128 Controller 3X-KZPEC-BF Smart Array 6404A/256 two 2 channel Controllers Overview The SA6400A is a high-performance Ultra320, PCI-X array controller. It provides maximum performance, flexibility, and reliable data protection for HP OpenVMS AlphaServers through its unique modular

More information

Hydra esata. 4-Bay RAID Storage Enclosure. User Manual January 16, 2009 - v1.0

Hydra esata. 4-Bay RAID Storage Enclosure. User Manual January 16, 2009 - v1.0 4-Bay RAID Storage Enclosure User Manual January 16, 2009 - v1.0 EN Table of Contents 1 Introduction... 1 1.1 System Requirements... 1 1.1.1 PC Requirements... 1 1.1.2 Mac Requirements... 1 1.1.3 Supported

More information

QuickSpecs. Models HP Smart Array E200 Controller. Upgrade Options Cache Upgrade. Overview

QuickSpecs. Models HP Smart Array E200 Controller. Upgrade Options Cache Upgrade. Overview Overview The HP Smart Array E200 is HP's first entry level PCI Express (PCIe) Serial Attached SCSI (SAS) RAID controller. The full size card has 8 ports and utilizes DDR1-266 memory. The E200 is ideal

More information

HP Array Technologies

HP Array Technologies 19 6717-4 CH13.qxd 9/15/04 5:11 PM Page 253 T H I R T E E N HP Array Technologies Chapter Syllabus 13.1 Advantages of HP Smart Array Controllers 13.2 HP Array Controller Utilities 13.3 Array Controller

More information

Promise FastTrak 100-Lite RAID Controller

Promise FastTrak 100-Lite RAID Controller Promise FastTrak 100-Lite RAID Controller User s Manual Version 1.3, November 9, 2001 Copyright Copyright by Promise Technology, Inc. ( Promise ), XP. No part of this manual may be reproduced or transmitted

More information

High Density RocketRAID 2711 + Rocket EJ220 Device Board Data RAID Installation Guide

High Density RocketRAID 2711 + Rocket EJ220 Device Board Data RAID Installation Guide High Density RocketRAID 2711 + Rocket EJ220 Device Board Data RAID Installation Guide Introduction The HighPoint High Density Storage Solutions hammer down high density storage cost over a single mini-

More information

HP Smart Array 5i Plus Controller and Battery Backed Write Cache (BBWC) Enabler

HP Smart Array 5i Plus Controller and Battery Backed Write Cache (BBWC) Enabler Overview HP Smart Array 5i Plus Controller and Battery Backed Write Cache (BBWC) Enabler Models Smart Array 5i Plus Controller and BBWC Enabler bundled Option Kit (for ProLiant DL380 G2, ProLiant DL380

More information

HP Embedded SATA RAID Controller

HP Embedded SATA RAID Controller HP Embedded SATA RAID Controller User Guide Part number: 391679-002 Second Edition: August 2005 Legal notices Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is

More information

HP ProLiant DL165 G7 Server. Installation Instructions

HP ProLiant DL165 G7 Server. Installation Instructions HP ProLiant DL165 G7 Server Installation Instructions Identifying server components Front panel components Figure 1 Front Panel Components / 4 3.5 HDD Item 1 Thumbscrews for rack mounting 2 Drive status

More information

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in HP Pavilion All-in-One MS200 series PC *579907-001* *579907-001* Printed in Upgrading and Servicing Guide Replacing a Wireless Keyboard or Mouse...2 Before You Begin... 2 Replacing the Keyboard or Mouse...

More information

3.5 Dual Bay USB 3.0 RAID HDD Enclosure

3.5 Dual Bay USB 3.0 RAID HDD Enclosure 3.5 Dual Bay USB 3.0 RAID HDD Enclosure User Manual August 11, 2011 v1.1 MFG Part # MT2U3-MP BARCODE Introduction 1 Introduction 1.1 System Requirements 1.1.1 PC Requirements Minimum Intel Pentium III

More information

This user guide describes features that are common to most models. Some features may not be available on your computer.

This user guide describes features that are common to most models. Some features may not be available on your computer. RAID User Guide Copyright 2011 Hewlett-Packard Development Company, L.P. Intel is a trademark of Intel Corporation in the U.S. and other countries. Microsoft and Windows are U.S. registered trademarks

More information

RAID 1(+0): breaking mirrors and rebuilding drives

RAID 1(+0): breaking mirrors and rebuilding drives RAID 1(+0): breaking mirrors and rebuilding drives How to, 3 rd edition Introduction... 2 Splitting a mirrored array using the Array Configuration Utility... 3 Recombining a split mirrored array using

More information

Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive

Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive This guide explains how to create and use a Rescue USB flash drive to reinstall and recover the ExtraHop system. When booting

More information

HP Embedded SATA RAID Controller

HP Embedded SATA RAID Controller HP Embedded SATA RAID Controller User Guide Part number: 433600-001 First Edition: June 2006 Legal notices Copyright 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject

More information

is605 Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives FW400 + FW800 + USB2.0 Combo External RAID 0, 1 Subsystem User Manual

is605 Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives FW400 + FW800 + USB2.0 Combo External RAID 0, 1 Subsystem User Manual is605 Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives FW400 + FW800 + USB2.0 Combo External RAID 0, 1 Subsystem User Manual (English/Deutsch/ 中 文 ) v1.0 August 23, 2007 Table of Contents CHAPTER

More information

QuickSpecs. What's New Boot from Tape. Models HP Smart Array P411 Controller

QuickSpecs. What's New Boot from Tape. Models HP Smart Array P411 Controller Overview The HP Smart Array P411 is HP's external connect only, PCI Express (PCIe) 2.0 Serial Attached SCSI (SAS) RAID controller for Integrity rack optimized servers. The low profile, half height card

More information

HP dx5150 RAID Installation and Setup Guide Version 1.10. Document Part Number: 403571-001

HP dx5150 RAID Installation and Setup Guide Version 1.10. Document Part Number: 403571-001 HP dx5150 RAID Installation and Setup Guide Version 1.10 Document Part Number: 403571-001 July 2005 Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject

More information

Configuring ThinkServer RAID 100 on the Lenovo TS130

Configuring ThinkServer RAID 100 on the Lenovo TS130 Configuring ThinkServer RAID 100 on the Lenovo TS130 Contents Overview 02 Embedded RAID 100 features on TS130 02 RAID Overview 02 Choosing the RAID Level 02 RAID 0 02 RAID 1 03 Configuring RAID 03 BIOS

More information

HP StorageWorks 8Gb Simple SAN Connection Kit quick start instructions

HP StorageWorks 8Gb Simple SAN Connection Kit quick start instructions HP StorageWorks 8Gb Simple SAN Connection Kit quick start instructions Congratulations on your purchase of the 8Gb Simple SAN Connection Kit. This guide provides procedures for installing the kit components,

More information

Taurus - RAID. Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives. User Manual

Taurus - RAID. Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives. User Manual Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives User Manual v1.0 August 23, 2007 EN Table of Contents CHAPTER 1 - INTRODUCTION 1 CHAPTER 3 - SYSTEM SET UP 9 ICON KEY 1 THE TAURUS RAID 1 AVAILABLE

More information

VIA / JMicron RAID Installation Guide

VIA / JMicron RAID Installation Guide VIA / JMicron RAID Installation Guide 1. Introduction to VIA / JMicron RAID Installation Guide. 3 2. VIA RAID Installation Guide. 3 2.1 VIA BIOS RAID Installation Guide.. 3 2.1.1 Introduction of RAID.

More information

SATA+Ultra ATA RAID CONTROLLER RC212. User Manual

SATA+Ultra ATA RAID CONTROLLER RC212. User Manual SATA+Ultra ATA RAID CONTROLLER RC212 Contents Feature and benefits Package contents System requirement Magic Switch introduction and jumper setting Hardware installation Important message for user RAID

More information

UPGRADING AND SERVICING GUIDE

UPGRADING AND SERVICING GUIDE UPGRADING AND SERVICING GUIDE HPTouchSmart 610 PC Computer features may vary by model. Removing and Replacing a CD/DVD Drive...2 Removing the CD/DVD Drive... 2 Installing a New CD/DVD Drive... 5 Removing

More information

5-BAY RAID STATION. Manual

5-BAY RAID STATION. Manual 5-BAY RAID STATION Manual Content 1. Features 3 1.1 Overview 3 1.2 SATA features 3 1.3 USB features 4 2. Specifications 4 3. System requirements 4 4. The device at a glance 4 4.1 Rear panel 5 4.2 The LED

More information

HP UPS R1500 Generation 3

HP UPS R1500 Generation 3 HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications

More information

Intel RAID Volume Recovery Procedures

Intel RAID Volume Recovery Procedures Intel RAID Volume Recovery Procedures Revision 1.0 12/20/01 Revision History Date Revision Number 12/20/01 1.0 Release Modifications Disclaimers Information in this document is provided in connection with

More information

5-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual

5-Bay Raid Sub-System Smart Removable 3.5 SATA Multiple Bay Data Storage Device User's Manual 5-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual www.vipower.com Table of Contents 1. How the SteelVine (VPMP-75511R/VPMA-75511R) Operates... 1 1-1 SteelVine

More information

QuickSpecs. HP Smart Array 5312 Controller. Overview

QuickSpecs. HP Smart Array 5312 Controller. Overview Overview Models 238633-B21 238633-291 (Japan) Feature List: High Performance PCI-X Architecture High Capacity Two Ultra 3 SCSI channels support up to 28 drives Modular battery-backed cache design 128 MB

More information

This chapter explains how to update device drivers and apply hotfix.

This chapter explains how to update device drivers and apply hotfix. MegaRAID SAS User's Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview This chapter explains an overview

More information

HP SATA/SAS hard drive and Solid State Drive installation

HP SATA/SAS hard drive and Solid State Drive installation HP SATA/SAS hard drive and Solid State Drive installation This document describes how to install Serial ATA (SATA) and Serial Attached SCSI (SAS) hard drives or Solid State Drives (SSD) in an internal

More information

Onboard-RAID. Onboard-RAID supports striping (RAID 0), mirroring (RAID 1), striping/mirroring (RAID 0+1), or spanning (JBOD) operation, respectively.

Onboard-RAID. Onboard-RAID supports striping (RAID 0), mirroring (RAID 1), striping/mirroring (RAID 0+1), or spanning (JBOD) operation, respectively. 1. Introduction Onboard-RAID IEI s Onboard-RAID is designed with Promise IDE RAID controller to provide a cost-effective, high performance RAID that adds performance and/or reliability to systems using

More information

Getting Started. rp5800, rp5700 and rp3000 Models

Getting Started. rp5800, rp5700 and rp3000 Models Getting Started rp5800, rp5700 and rp3000 Models Copyright 2011 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft, Windows, and Windows

More information

Acano solution. Acano Solution Installation Guide. Acano. January 2014 76-1002-03-B

Acano solution. Acano Solution Installation Guide. Acano. January 2014 76-1002-03-B Acano solution Acano Solution Installation Guide Acano January 2014 76-1002-03-B Contents Contents 1 Introduction... 3 1.1 Before You Start... 3 1.1.1 Safety information... 3 1.1.2 You will need the following

More information

Configuring ThinkServer RAID 500 and RAID 700 Adapters. Lenovo ThinkServer

Configuring ThinkServer RAID 500 and RAID 700 Adapters. Lenovo ThinkServer Configuring ThinkServer RAID 500 and RAID 700 Adapters Lenovo ThinkServer October 4, 2011 Contents Overview... 4 RAID 500 features... 4 RAID 700 features... 4 RAID Overview... 4 Choosing the RAID Level...

More information

Intel Matrix Storage Console

Intel Matrix Storage Console Intel Matrix Storage Console Reference Content January 2010 Revision 1.0 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE,

More information

RAID Utility User Guide. Instructions for setting up RAID volumes on a computer with a Mac Pro RAID Card or Xserve RAID Card

RAID Utility User Guide. Instructions for setting up RAID volumes on a computer with a Mac Pro RAID Card or Xserve RAID Card RAID Utility User Guide Instructions for setting up RAID volumes on a computer with a Mac Pro RAID Card or Xserve RAID Card Contents 3 RAID Utility User Guide 3 The RAID Utility Window 4 Running RAID Utility

More information

HP ProLiant DL380 Generation 5 Server User Guide

HP ProLiant DL380 Generation 5 Server User Guide HP ProLiant DL380 Generation 5 Server User Guide Part Number 403166-005 September 2007 (Fifth Edition) Copyright 2006, 2007 Hewlett-Packard Development Company, L.P. The information contained herein is

More information

Offline Array Recovery Procedures SuperTrak SX6000 and UltraTrak

Offline Array Recovery Procedures SuperTrak SX6000 and UltraTrak Version 5a Offline Array Recovery Procedures SuperTrak SX6000 and UltraTrak This document describes the procedures for protecting data and restoring array status to arrays that have gone OFFLINE. Promise

More information

SATA II 4 Port PCI RAID Card RC217 User Manual

SATA II 4 Port PCI RAID Card RC217 User Manual SATA II 4 Port PCI RAID Card RC217 SATA II 4 Port PCI RAID Card This Manual is for many Models of SATAII RAID5 HBA that uses Silicon Image SATA II SiI3124 chipset: 1) 32bit PCI bus host card 2) 64bit PCI-X

More information

SATARAID5 Serial ATA RAID5 Management Software

SATARAID5 Serial ATA RAID5 Management Software SATARAID5 Serial ATA RAID5 Management Software Home Edition Preliminary Draft Subject to Change Without Notice 05/7/04 Silicon Image, Inc. 1060 East Arques Ave. Sunnyvale CA 94085 (408) 616-4000 www.siliconimage.com

More information

Compaq Presario Desktop Products. Upgrading and Servicing Guide

Compaq Presario Desktop Products. Upgrading and Servicing Guide Compaq Presario Desktop Products Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to

More information

RAID Utility User s Guide Instructions for setting up RAID volumes on a computer with a MacPro RAID Card or Xserve RAID Card.

RAID Utility User s Guide Instructions for setting up RAID volumes on a computer with a MacPro RAID Card or Xserve RAID Card. RAID Utility User s Guide Instructions for setting up RAID volumes on a computer with a MacPro RAID Card or Xserve RAID Card. 1 Contents 3 RAID Utility User s Guide 3 Installing the RAID Software 4 Running

More information

HP StorageWorks 60 Modular Smart Array Enclosure User Guide

HP StorageWorks 60 Modular Smart Array Enclosure User Guide HP StorageWorks 60 Modular Smart Array Enclosure User Guide November 2006 (Second Edition) Part Number 405868-002 Copyright 2006 Hewlett-Packard Development Company, L.P. The information contained herein

More information

Aberdeen AberNAS 110 RAID Recovery Technical Brief

Aberdeen AberNAS 110 RAID Recovery Technical Brief Aberdeen AberNAS 110 RAID Recovery Technical Brief Aberdeen LLC. Charles D. Jansen Published: February 2005 Abstract This Aberdeen technical brief provides a quick step by step procedure required to repair

More information

ITE RAID Controller USER MANUAL

ITE RAID Controller USER MANUAL ITE RAID Controller USER MANUAL 120410096E1N Copyright Copyright 2004. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system or translated

More information

HP ProLiant DL/ML370 G6 Server User Guide

HP ProLiant DL/ML370 G6 Server User Guide HP ProLiant DL/ML370 G6 Server User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing

More information

SATA RAID SIL 3112 CONTROLLER USER S MANUAL

SATA RAID SIL 3112 CONTROLLER USER S MANUAL SATA RAID SIL 3112 CONTROLLER USER S MANUAL 120410056E1N Copyright Copyright 2003. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system

More information

Recovering from a Hard Drive Failure

Recovering from a Hard Drive Failure APPENDIXB This appendix describes how to recover from a hard drive failure on a Multiservices Platform Series device. The process for doing so depends on the physical security product that you are using

More information

HP VMware ESXi 5.0 and Updates Getting Started Guide

HP VMware ESXi 5.0 and Updates Getting Started Guide HP VMware ESXi 5.0 and Updates Getting Started Guide Abstract This guide is intended to provide setup information for HP VMware ESXi. HP Part Number: 616896-002 Published: August 2011 Edition: 1 Copyright

More information

Guide to SATA Hard Disks Installation and RAID Configuration

Guide to SATA Hard Disks Installation and RAID Configuration Guide to SATA Hard Disks Installation and RAID Configuration 1. Guide to SATA Hard Disks Installation... 2 1.1 Serial ATA (SATA) Hard Disks Installation... 2 2. Guide to RAID Configurations... 3 2.1 Introduction

More information

Using ATI Array Management Software (WebPAM)

Using ATI Array Management Software (WebPAM) Redundant Array of Independent Disks (RAID) on HP Compaq dc5750 Business PCs Using ATI Array Management Software (WebPAM) Introduction............................................................ 2 Mirroring

More information

McAfee Firewall Enterprise

McAfee Firewall Enterprise Hardware Guide Revision C McAfee Firewall Enterprise S1104, S2008, S3008 The McAfee Firewall Enterprise Hardware Product Guide describes the features and capabilities of appliance models S1104, S2008,

More information

2-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual

2-Bay Raid Sub-System Smart Removable 3.5 SATA Multiple Bay Data Storage Device User's Manual 2-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual www.vipower.com Table of Contents 1. How the SteelVine (VPMP-75211R/VPMA-75211R) Operates... 1 1-1 SteelVine

More information

AMD RAID Installation Guide

AMD RAID Installation Guide AMD RAID Installation Guide 1. AMD BIOS RAID Installation Guide.. 2 1.1 Introduction to RAID.. 2 1.2 RAID Configurations Precautions 3 1.3 Installing Windows 7 / 7 64-bit / Vista / Vista 64-bit / XP /

More information

HP R12000 and R18000 DirectFlow UPS User Guide

HP R12000 and R18000 DirectFlow UPS User Guide HP R12000 and R18000 DirectFlow UPS User Guide Abstract This document includes installation, configuration, and operation information for the HP R12000 and R18000 DirectFlow UPS. This document is for the

More information

How To Use An Hp Smart Array P212 (Sas) With A 1-Year Warranty On A 2 Terabyte Hard Drive (Sata) And A 1 Terabyte (Sasa) Hard Drive With A 2-Year License (S

How To Use An Hp Smart Array P212 (Sas) With A 1-Year Warranty On A 2 Terabyte Hard Drive (Sata) And A 1 Terabyte (Sasa) Hard Drive With A 2-Year License (S Overview The HP Smart Array P212 is HP's entry level PCI Express (PCIe) Serial Attached SCSI (SAS) RAID controller. The low profile, half height card has 8 ports and utilizes DDR2-800 memory. The P212

More information

Encore SATA2 RAID PCIe Card

Encore SATA2 RAID PCIe Card Encore SATA2 RAID PCIe Card User Manual Ver. 2.00 All brand names and trademarks are properties of their Respective owners. 1 Features and Benefits Compliant with PCI Express Base Specification 1.0a Compliant

More information

Mylex Online RAID Expansion Enhancement for DACCF Utilities 4.4 and Global Array Manager 2.05. Part Number 771968-D01

Mylex Online RAID Expansion Enhancement for DACCF Utilities 4.4 and Global Array Manager 2.05. Part Number 771968-D01 MORE User Guide Mylex Online RAID Expansion Enhancement for DACCF Utilities 4.4 and Global Array Manager 2.05 Part Number 771968-D01 Copyright 1996 Mylex Corporation. All Rights Reserved. All contents

More information

Ultra ATA 133 RAID PCI Pro

Ultra ATA 133 RAID PCI Pro Ultra ATA 133 RAID PCI Pro 1-1 Introduction Quick Installation Guide This ultra high-speed dual channel Ultra ATA/133 RAID controller is designed to support RAID 0, 1, 0+1 and JBOD. RAID configurations

More information

Upgrading or Replacing a Host Interface Card in the 6580/6780 Controller Module

Upgrading or Replacing a Host Interface Card in the 6580/6780 Controller Module Upgrading or Replacing a Host Interface Card in the 6580/6780 Controller Module May 2011 51358-00, Rev. A ST2501 M2 Drive Module Initial Setup Guide May 2011 Revision History Version and Date 51358-00,

More information

SATA RAID Function (Only for chipset Sil3132 used) User s Manual

SATA RAID Function (Only for chipset Sil3132 used) User s Manual SATA RAID Function (Only for chipset Sil3132 used) User s Manual 12ME-SI3132-001 Table of Contents 1 WELCOME...4 1.1 SATARAID5 FEATURES...4 2 AN INTRODUCTION TO RAID...5 2.1 DISK STRIPING (RAID 0)...5

More information

NEC ESMPRO Manager RAID System Management Guide for VMware ESXi 5 or later

NEC ESMPRO Manager RAID System Management Guide for VMware ESXi 5 or later NEC ESMPRO Manager RAID System Management Guide for VMware ESXi 5 or later 856-127900-613-G 7th Edition Jun. 2015 Copyright NEC Corporation 2015. Trademarks NEC EXPRESSBUILDER is trademarks of NEC Corporation.

More information

TECHNOLOGY BRIEF. Compaq RAID on a Chip Technology EXECUTIVE SUMMARY CONTENTS

TECHNOLOGY BRIEF. Compaq RAID on a Chip Technology EXECUTIVE SUMMARY CONTENTS TECHNOLOGY BRIEF August 1999 Compaq Computer Corporation Prepared by ISSD Technology Communications CONTENTS Executive Summary 1 Introduction 3 Subsystem Technology 3 Processor 3 SCSI Chip4 PCI Bridge

More information

ProLiant DL380 Generation 2 Server Maintenance and Service Guide

ProLiant DL380 Generation 2 Server Maintenance and Service Guide ProLiant DL380 Generation 2 Server Maintenance and Service Guide Second Edition (June 200) Part Number 203840-002 Spare Part Number 228520-00 Compaq Computer Corporation Notice 200 Compaq Computer Corporation

More information

HP Online ROM Flash. User Guide

HP Online ROM Flash. User Guide HP Online ROM Flash User Guide Part number: 216315-010 Tenth edition: March 2006 Legal notices Copyright 2000, 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject

More information

SiS964 RAID. User s Manual. Edition. Trademarks V1.0 P/N: 91-187-U49-M2-0E

SiS964 RAID. User s Manual. Edition. Trademarks V1.0 P/N: 91-187-U49-M2-0E SiS964 RAID User s Manual Edition V1.0 P/N: 91-187-U49-M2-0E Trademarks All brand or product names mentioned are trademarks or registered trademarks of their respective holders. CONTENTS Introduction...

More information

Areas Covered. Chapter 1 Features (Overview/Note) Chapter 2 How to Use WebBIOS. Chapter 3 Installing Global Array Manager (GAM)

Areas Covered. Chapter 1 Features (Overview/Note) Chapter 2 How to Use WebBIOS. Chapter 3 Installing Global Array Manager (GAM) PRIMERGY RX300 S2 Onboard SCSI RAID User s Guide Areas Covered Chapter 1 Features (Overview/Note) This chapter explains the overview of the disk array and features of the SCSI array controller. Chapter

More information

WebBIOS Configuration Utility Guide

WebBIOS Configuration Utility Guide Dell PowerEdge Expandable RAID Controller 3/QC, 3/DC, 3/DCL and 3/SC WebBIOS Configuration Utility Guide www.dell.com support.dell.com Information in this document is subject to change without notice.

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should be construed

More information

RocketRAID 1640. User's Manual. Revision: 1.0 Date: Mar. 2003 HighPoint Technologies, Inc.

RocketRAID 1640. User's Manual. Revision: 1.0 Date: Mar. 2003 HighPoint Technologies, Inc. RocketRAID 1640 User's Manual Revision: 1.0 Date: Mar. 2003 HighPoint Technologies, Inc. Copyright Copyright 2003 HighPoint Technologies, Inc.. This document contains materials protected by International

More information

USER S GUIDE. MegaRAID SAS Software. June 2007 Version 2.0. 80-00156-01, Rev. B

USER S GUIDE. MegaRAID SAS Software. June 2007 Version 2.0. 80-00156-01, Rev. B USER S GUIDE MegaRAID SAS Software June 2007 Version 2.0 80-00156-01, Rev. B This document contains proprietary information of LSI Corporation. The information contained herein is not to be used by or

More information

User s Manual. Home CR-H212. 2.5 2-BAY RAID Storage Enclosure

User s Manual. Home CR-H212. 2.5 2-BAY RAID Storage Enclosure User s Manual Home CR-H212 2.5 2-BAY RAID Storage Enclosure 1 Introduction 1.1 Features - 2-Bay Bus Powered Portable RAID Enclosure -Works with SATA HDD or SSD -Supports Big (JBOD), RAID0, RAID1, and Normal

More information

Cisco NAC Appliance Hardware Platforms

Cisco NAC Appliance Hardware Platforms 1 CHAPTER This chapter provides general information on the Cisco NAC Appliance network access control system, as well as hardware specifications for all Clean Access Manager (CAM) and Clean Access Server

More information

RAIDCore User Manual P/N 83-00004638-12 Revision A December 2009

RAIDCore User Manual P/N 83-00004638-12 Revision A December 2009 RAIDCore User Manual P/N 83-00004638-12 Revision A December 2009 Copyright Protected Material 2009. All rights reserved. All other trademarks and registered trademarks are proprietary to their respective

More information

System Release Notes Express5800/320LB System Release Notes

System Release Notes Express5800/320LB System Release Notes System Release Notes Express5800/320LB System Release Notes PN: 455-01681-004 2 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related

More information