Hands-on Workshop on Advanced Hydrocarbon Analysis July 23, 2015
|
|
|
- Caren Pearson
- 9 years ago
- Views:
Transcription
1 Hands-on Workshop on Advanced Hydrocarbon Analysis July 23, 2015 Fast Analysis of Natural Gas and Fuel Gas Using Agilent 490 Micro GC - David Ramby, Quantum Analytics
2 Quantum Analytics Value-added distributor of multi-vendor analytical instruments Cross-platform system integration, installation, training and product support Multi-million dollar inventory of new and refurbished instruments available for immediate delivery
3 Quantum Analytics Rent, lease or purchase the instrument your lab needs today! Zero Down, Zero Interest Financing for 12 months Low Cost Capital Lease Options Rental with Equity
4 Fast Analysis of Natural Gas and Fuel Gas Using Agilent 490 MicroGC Quantum Tech Center Oak Ridge North, TX July 23, 2015 David Ramby Product Application Specialist Quantum Analytics
5 Agilent 490 MicroGC The Agilent 490 MicroGC is the fifth generation rugged and compact analyzer for gas quality analysis in the laboratory, online / at-line and in the field.
6 Modular and ready-to-go Two bench-top cabinets are available the DUAL for 1 or 2 channels and the QUAD for 1 to 4 GC channels. Every channel is a complete, miniaturized GC, with independently controlled Electronic Gas Control Chip Injector GC Column Micro TCD injection volume, column oven temperature and carrier gas.
7 Designed for flexibility and ease-of-use The Agilent 490 MicroGC provides maximum flexibility and customization: Sampling via sample pump or continuous flow Heated or non-heated injector/sample line Up to 2 different sample inlets Sample inlet at the rear or front Up to 2 different carrier gases Column back flush option
8 The Micro Gasifier expands the range of samples you can analyze The Micro Gasifier provides controlled evaporation of Liquid Petroleum Gas (LPG) and Liquefied Natural Gas (NGA). In addition, high pressure can be reduced without the creation of cold spots.
9 The field case provides on-the-go measurements The field case is compact in size and weight, and includes carrier gas supply and battery pack.
10 Use accessories more conveniently with the integrated accessory bracket The MicroGC accessory bracket is an on-board universal mounting platform for accessories such as stream selector valve, Micro Gasifier, Genie membrane filters, pressure regulator and sample relief valve.
11 For on-line analysis, a 19 rack mounted version is available The 490 and 490-PRO MicroGCs are also available in a 19 rack-mounted chassis. Sampling and sample conditioning devices, such as stream selection valves and Genie membrane filters, can be mounted inside the housing.
12 490-PRO MicroGC: no local operator required The 490-PRO MicroGC does not require an external computer to generate data and results. It features on-board data collection, integration and results calculation. User defined information is automatically sent to an external control system.
13 PRO for PROCESS The 490-PRO MicroGC David Ramby Product Application Specialist Quantum Analytics Confidentiality Label
14 490-PRO MicroGC Markets A Fast, Small Form Factor, High Performance Gas Measurement Platform Designed for Unattended Operation and supports Industrial networks Product differentiation Process environment On-line / At-line Product Benefits Implement proven Lab Technology in Process Analytics Instrument hardware availability for autonomous operation Communicates results instead of raw signal data 11
15 Agilent 490-PRO MicroGC Micro machined injector One to four independently controlled, micro-machined, plug-n-play GC channels Same hardware as 490 MicroGC Electronic gas control Narrow-bore column Micro Thermal Conductivity Detector Dual Quad 12
16 All the intelligence is inside the 490-PRO MicroGC On-board data handling Peak integration, identification, grouping, calibration and normalization with using external PC with CDS Results only! Modbus TCP/IP, Modbus serial (optional), 4-20 ma, FTP-server Energy metering (optional) Calculation of calorific value, density, compressibility etc. In accordance to ISO 6976, ASTM D3588, GPA 2172, GOST & GOST 31369* Requires additional license History logging (optional) 35 day storage of analysis results, calibration data, error log, etc. In according to API (chapter21) Webserver Available from anywhere on the internet Status and last analysis results * currently limited to particular OEM 13
17 490-PRO versus 490 MicroGC Set up / Operation PC with CDS Control Signal 490 MicroGC Standard 490 MicroGC Report 14
18 490-PRO versus 490 MicroGC Set up / Operation PC with CDS Control Signal 490 MicroGC Standard 490 MicroGC Report Set up PC with PROstation Method Maintenance 490-PRO 490-PRO MicroGC 15
19 490-PRO versus 490 MicroGC Set up / Operation PC with CDS Control Signal 490 MicroGC Standard 490 MicroGC Report Set up PC with PROstation Method Maintenance 490-PRO 490-PRO MicroGC Operation PC PROstation 490-PRO Communication Result Industrial networks 16
20 What is PROstation? Tool to setup the 490-PRO Application method development Integration, peak identification Calibration, validation and normalization Energy metering settings and component constants External I/O s (alarms, 4-20 ma) MODBUS register setup LCD display parameters It displays info obtained from instrument Instrument status Chromatograms Integration parameters Calibration curves Results All settings are send to the 490-PRO, where all intelligence is. 17
21 Calorific value calculations ISO 6976 / GOST / GOST31369 GPA 2172 / ASTM D-3588 Unnormalized concentration per component ppm, % Unnormalized concentration per component ppm, % Normalized concentration per component ppm, % Normalized concentration per component ppm, % Compressibility Compressibility Molar Mass kg/kmol Molar Mass lb/lbmol Molar Mass Ratio Molar Mass Ratio Relative Density Gross Heating Value Btu/ft 3 Absolute Density Kg/m 3 Gross Heating Value for dry real gas Btu/ft 3 Superior Heating Value MJ/m 3 Gross Heating Value for water saturated real gas Btu/ft 3 Inferior Heating Value MJ/m 3 Net Heating Value Btu/ft 3 Wobbe Index based on Superior Heating Value MJ/m 3 Net Heating Value for dry real gas Btu/ft 3 Wobbe Index based on Inferior Heating Value MJ/m 3 Net Heating Value for water saturated real gas Btu/ft 3 Calculation in accordance to: Specific Gravity (Relative Density for real gas) Wobbe Index Btu/ft 3 Gross Heating Value converted to MJ/m 3 MJ/m 3 Net Heating Value converted to MJ/m 3 MJ/m 3 Mass Density lb/ft3 lb/ft3 Spec. volume ft3/lb ft3/lb GPM Total ft3/gal ft3/gal GPM per compound ft3/gal ft3/gal Weight % per component % 18
22 Accessories LCD User definable time based scrolling of sample results, GC status, Error information, etc. Extension boards (basic, digital and analog) Stackable up to 8 boards with 64 x relays, 25 x analog outputs, 4-20mA outputs, 0-1V, 64 x digital I/O s mountable on DIN-rail Micro Gasifier Heated pressure reducer for Liquefied Natural Gas (LNG) and Liquefied Petroleum Gas (LPG) 19
23 Accessories Genie filter Particle and droplet removal Stream selection Valco stream selector valve Solenoid valve relay switch (using Extension boards) 19 rack housing Simplifies process integration Can hold accessories like genie filter, LCD, SSV micro gasifier, extension boards etc. 20
24 Typical 490-PRO peripheral 21
25 Process market requirements On-line, 24/7, unattended operation Speed of analysis Connection to process system Small instrument size for easy integration Single method - Results only Sensor / Monitoring type Analysis Reliable instrumentation 22
26 System integration Agilent responsibilities: Provides hardware (490-PRO, SSV, LCD, Extension boards, 19 tack housing) Provides the analytical application Results available via ModBus and FTP Search for (local) system integrator Wikipedia: A Systems Integrator is a person or company that specializes in bringing together component subsystems into a whole and ensuring that those subsystems function together, a practice known as System Integration. Customer responsibilities: Sample inlet tubing Sample conditioning DCS connections and DCS programming Display mounting Collecting results via ModBus, 4-20 ma I/O Cable connection 23
27 Agilent 490 MicroGC Improved detection limit specifications April May 2015
28 Agilent 490 Micro GC Fast and accurate gas analysis platform FAST Typical run time 30 to 120 seconds ANALYZERS Factory configured & tuned Saves on method development time APPLICATIONS Natural gas composition and odorants Biogas Refinery gases Oil exploration / mud logging Mine safety analysis Specialty gas quality control Air monitoring PROCESS on-board data handling energy metering OUT-OF-LAB 25 May 2015
29 Improved Product Specifications When Detection Limits Matter Detection Limits * Wall Coated Open Tubular column CP-Sil 5 CB, CP-Sil 13 CB, CP-Sil 19 CB and CP-WAX 52 CB WAX 52 CB Porous Layer Open Tubular & Micro-Packed column column Molsieve 5A, PoraPLOT Q, PoraPLOT U, Aluminumoxide, Aluminumoxide, SilicaPLOT, MES column and HayeSep A HayeSep A Micro-packed column CP-COx From April 1 st, 2015: New Limit of Detection Old Spec New Spec 1 ppm 0.5 ppm 10 ppm ppm 10 ppm ppm 2 ppm 10 ppm * Detection limits are typical for selected components provided that the proper column proper column length and chromatographic conditions are used. Improved product quality has resulted in 5 times lower LOD s - down to 0.5 ppm. Lower LOD s enables better quality control and gain more reliable results. 26 May 2015
30 Importance of low limit of detection Coal mine safety analysis Safety challenge is a early warning for indication of spontaneous combustion in coal mines. New factory LOD specs of 2 ppm 2 ppm of C2 isomers on a PoraPLOT U 27 May 2015
31 Importance of low limit of detection Environmental analysis of aromatic hydrocarbons Environmental challenge is the analysis of BTEX in air New factory LOD specs of 0.5 ppm using the CP-Sil 5 CB column Benzene 0.5 ppm Application areas: Fence Line Monitoring Landfill sites Industrial areas Traffic 28 May 2015
32 Importance of low limit of detection Carbon dioxide analysis Analysis of low levels of carbon dioxide. New factory LOD specs of 10 ppm 10 ppm of CO 2 on a CP-COx column Linearity R 2 = May 2015
33 Multiple Applications For production and research, the Agilent 490 MicroGC provides gas analysis in matter of seconds for: Natural gas / calorific value determination Analysis of simple to complex refinery gases Oil and exploration / mud logging Analysis and quality control of specialty gases Biogas Assessing efficiency of catalysts, fuel cell stacks Air monitoring
34 Natural Gas Analysis A complete range of natural gas analysis solutions Easy to operate, powerful GC solutions Comprehensive single-vendor solution US/Products/Instruments/gc/microgc/analyzers/nat uralgas/pages/default.aspx
35 Natural Gas Analysis within 45 seconds Propane Methane i-butane Butane Nitrogen CO2 Ethane i-pentane Pentane Hexane 2 Sec 50 Column: HayeSepA 5 Sec 45 Column: CP-Sil 5 CB
36 Extended Natural Gas Analysis i-c5 C5 C6 Benzene C8 C9 C10 Extended Hydrocarbon and Odorant (THT) analysis in Natural Gas 1.2 Min 3 C7 C8 C9 C Min 3 Column: CP-Sil 5 CB THT Nonane 2 Sec 50 Column: CP-Sil 19 CB
37 Natural Gas Analysis A complete range of natural gas analysis solutions Easy to operate, powerful GC solutions Comprehensive single-vendor solution
38 Agilent 490 MicroGC Natural Gas Analyzers
39 Natural Gas Permanent gases Hydrocarbons Odorants Compound Typical Concentration (%) [1] Methane Ethane Propane 0-20 Butane Carbon dioxide 0 8 Oxygen Nitrogen 0 5 Hydrogen sulphide 0 5 Other: Helium, Argon, Neon, Xeon, Hydrogen Traces Micro-Gasifier for Liquefied Natural Gas (LNG) sample introduction Reference [1]: http//:naturalgas.org 36
40 490 MicroGC Natural Gas Analyzers Easy to Order Easy to Install Fast to deliver Single part number, easy to quote and order Application Note, Data Sheet and Solutions web site Factory Tested with Check-Out sample (delivered with the Analyzer) Analytical method parameters, Data files, User manual and Reports included * Made-tostock, available for shipment from the LCs worldwide Application Note & Data Sheet Available 37
41 Natural Gas Analyzer portfolio Analyzer characteristics Natural Gas Analyzer A Natural Gas Analyzer A Extended Natural Gas Analyzer B Natural Gas Analyzer B Extended Option number G3582A#120 G3582A#121 G3582A#122 G3582A#123 Micro GC cabinet Dual with 2 channels Quad with 3 channels Dual with 2 channels Quad with 3 channels Column channels installed Analysis HayeSep A 40 cm, without back flush CP-Sil 5 CB 6 m, without back flush Hydrocarbons C1-C9 HayeSep A 40 cm, with back flush CP-Sil 5 CB 4 m, with back flush CP-Sil 5 CB 8 m, without back flush Hydrocarbons C1-C12 PoraPLOT U 10 m, with backflush CP-Sil 5 CB 6 m, without back flush Hydrocarbons C1-C9 CP-MolSieve 5A 10 m, with backflush and retention time stability option PoraPLOT U 10 m, with backflush CP-Sil 5 CB 6 m, without back flush Hydrocarbons C1-C9 Carbon dioxide, Air Carbon dioxide, Air Carbon dioxide, Air Carbon dioxide, Air Hydrogen sulfide Hydrogen sulfide Permanent gases (N 2, O 2, He & H 2 ) Typical analysis 100 s (until C7) 100 s (until C7) 75 s (until C7) 75 s (until C7) time 400 s (until C9) 240 s (until C12) 400 s (until C9) 400 s (until C9) 38
42 Natural Gas Analyzer A Natural gas; composition primarily CH 4, Air, CO 2 andc2 C9 hydrocarbons Dual channel cabinet with 2 column channels Heated sample line and injectors 0.4 m HayeSep A and 6 m CP-Sil 5 CB column channels Part number G3582A + G3582A# m HayeSep A 39
43 Natural Gas Analyzer A 6 m CP-Sil 5 CB 40
44 Natural Gas Analyzer A Extended Natural gas with extended hydrocarbon range Quad channel cabinet with 3 column channels C4 to C12 hydrocarbon analyzed on 2 separate CP-Sil 5 CB channels Part number G3582A + G3582A#121 Channel 1 identical to Natural Gas Analyzer B (#120) 4 m CP-Sil 5 CB w/ BF 41
45 Natural Gas Analyzer A Extended 8 m CP-Sil 5 CB 42
46 Natural Gas Analyzer B Natural gas; composition primarily CH 4, Air, CO 2, C2 C9 hydrocarbons Dual channel cabinet with 2 column channels Heated sample line and injectors PPU equipped with Backflush functionality UltiMetal treated sample lines: ready for H2S analysis Part number G3582A + G3582A# m PoraPLOT U 43
47 Natural Gas Analyzer B 6 m CP-Sil 5 CB 44
48 Natural Gas Analyzer B Extended Natural gas with detailed Permanent Gas Analysis Quad channel cabinet with 3 column channels Channel 1 & 2 identical to Natural Gas Analyzer B (#122) Separate carrier gas inlet to have the flexibility to change between helium and argon 10 m MolSieve 5A Part number G3582A + G3582A#123 45
49 Quantum Preferred - Natural Gas Analyzer Two Channel Analyzer characteristics Natural Gas Analyzer A Natural Gas Analyzer A Extended Natural Gas Analyzer B Natural Gas Analyzer B Extended Option number G3582A#120 G3582A#121 G3582A#122 G3582A#123 Micro GC cabinet Dual with 2 channels Quad with 3 channels Dual with 2 channels Quad with 3 channels Column channels installed Analysis HayeSep A 40 cm, without back flush CP-Sil 5 CB 6 m, without back flush Hydrocarbons C1-C9 HayeSep A 40 cm, with back flush CP-Sil 5 CB 4 m, with back flush OR CP-Sil 5 CB 8 m, without back flush Hydrocarbons C1-C12 PoraPLOT U 10 m, with backflush CP-Sil 5 CB 6 m, without back flush Hydrocarbons C1-C9 CP-MolSieve 5A 10 m, with backflush and retention time stability option PoraPLOT U 10 m, with backflush CP-Sil 5 CB 6 m, without back flush Hydrocarbons C1-C9 Carbon dioxide, Air Carbon dioxide, Air Carbon dioxide, Air Carbon dioxide, Air Hydrogen sulfide Hydrogen sulfide Permanent gases (N 2, O 2, He & H 2 ) Typical analysis 100 s (until C7) 100 s (until C7) 75 s (until C7) 75 s (until C7) time 400 s (until C9) 240 s (until C12) 400 s (until C9) 400 s (until C9) 46
50 Quantum Preferred Extended NGA Three Channel for Permanent Gases Analyzer characteristics Natural Gas Analyzer A Natural Gas Analyzer A Extended Natural Gas Analyzer B Natural Gas Analyzer B Extended Option number G3582A#120 G3582A#121 G3582A#122 G3582A#123 Micro GC cabinet Dual with 2 channels Quad with 3 channels Dual with 2 channels Quad with 3 channels Column channels installed Analysis HayeSep A 40 cm, without back flush CP-Sil 5 CB 6 m, without back flush Hydrocarbons C1-C9 HayeSep A 40 cm, with back flush CP-Sil 5 CB 4 m, with back flush OR CP-Sil 5 CB 8 m, without back flush Hydrocarbons C1-C12 PoraPLOT U 10 m, with backflush CP-Sil 5 CB 6 m, without back flush Hydrocarbons C1-C9 CP-MolSieve 5A 10 m, with backflush and retention time stability option PoraPLOT U 10 m, with backflush CP-Sil 5 CB 6 m, without back flush Hydrocarbons C1-C9 Carbon dioxide, Air Carbon dioxide, Air Carbon dioxide, Air Carbon dioxide, Air Hydrogen sulfide Hydrogen sulfide Permanent gases (N 2, O 2, He & H 2 ) Typical analysis 100 s (until C7) 100 s (until C7) 75 s (until C7) 75 s (until C7) time 400 s (until C9) 240 s (until C12) 400 s (until C9) 400 s (until C9) 47
51 Quantum Preferred Extended NGA Three Channel for Hydrocarbon Groups to C12 Analyzer characteristics Natural Gas Analyzer A Natural Gas Analyzer A Extended Natural Gas Analyzer B Natural Gas Analyzer B Extended Option number G3582A#120 G3582A#121 G3582A#122 G3582A#123 Micro GC cabinet Dual with 2 channels Quad with 3 channels Dual with 2 channels Quad with 3 channels Column channels installed Analysis HayeSep A 40 cm, without back flush CP-Sil 5 CB 6 m, without back flush Hydrocarbons C1-C9 HayeSep A 40 cm, with back flush CP-Sil 5 CB 4 m, with back flush AND CP-Sil 5 CB 8 m, without back flush Hydrocarbons C1-C12 PoraPLOT U 10 m, with backflush CP-Sil 5 CB 6 m, without back flush Hydrocarbons C1-C9 CP-MolSieve 5A 10 m, with backflush and retention time stability option PoraPLOT U 10 m, with backflush CP-Sil 5 CB 6 m, without back flush Hydrocarbons C1-C9 Carbon dioxide, Air Carbon dioxide, Air Carbon dioxide, Air Carbon dioxide, Air Hydrogen sulfide Hydrogen sulfide Permanent gases (N 2, O 2, He & H 2 ) Typical analysis 100 s (until C7) 100 s (until C7) 75 s (until C7) 75 s (until C7) time 400 s (until C9) 240 s (until C12) 400 s (until C9) 400 s (until C9) 48
52 Quantum Preferred Extended NGA Four Channel for HC Groups to C12 and N2/O2 Analyzer characteristics Natural Gas Analyzer A Natural Gas Analyzer A Extended Natural Gas Analyzer B Natural Gas Analyzer B Extended Option number G3582A#120 G3582A#121 G3582A#122 G3582A#123 Micro GC cabinet Dual with 2 channels Quad with 3 channels Dual with 2 channels Quad with 3 channels Column channels installed Analysis HayeSep A 40 cm, without back flush CP-Sil 5 CB 6 m, without back flush Hydrocarbons C1-C9 HayeSep A 40 cm, with back flush CP-Sil 5 CB 4 m, with back flush AND CP-Sil 5 CB 8 m, without back flush Hydrocarbons C1-C12 PoraPLOT U 10 m, with backflush CP-Sil 5 CB 6 m, without back flush Hydrocarbons C1-C9 CP-MolSieve 5A 10 m, with backflush and retention time stability option PoraPLOT U 10 m, with backflush CP-Sil 5 CB 6 m, without back flush Hydrocarbons C1-C9 Carbon dioxide, Air Carbon dioxide, Air Carbon dioxide, Air Carbon dioxide, Air Hydrogen sulfide Hydrogen sulfide Permanent gases (N 2, O 2, He & H 2 ) Typical analysis 100 s (until C7) 100 s (until C7) 75 s (until C7) 75 s (until C7) time 400 s (until C9) 240 s (until C12) 400 s (until C9) 400 s (until C9) 49
53 EZReporter for calorific value calculations Option number G3582A#105 External software compatible with Agilent CDS Key parameters available: In printed format As an export For monitoring incl min/max values For trend analysis Product description EZReporter for calorific value / BTU calculations Compatible with Agilent EZChrom , Agilent OpenLAB CDS EZChrom Edition and Agilent OpenLAB CDS ChemStation Edition Supported standards GPA ASTM D (2003) ISO 6976 (1995) 50
54 Quantum 490 MicroGC Natural Gas Analyzers Easy to Order Easy to Install Contact Quantum, and we will respond with a correctly configured quote Application Note (not yet) Quantum Tech Center Tested with Check-Out sample (delivered with the Analyzer) Analytical method parameters, Data files, User manual and Reports included * Quantum Tech Center or on-site training can be provided 51
55 Refinery Gas Analysis A complete range of refinery gas analysis solutions Easy to operate, powerful GC solutions Comprehensive single-vendor solution US/Products/Instruments/gc/microgc/analyzers/refi nerygas/pages/default.aspx
56 Refinery Gas Analysis on a Quad MicroGC Channel 1: MolSieve5A Peak Identification 1 Hydrogen 2 Oxygen 3 Nitrogen 4 Carbon monoxide 7 Methane Peak Identification 5 Carbon dioxide 6 Hydrogen sulfide 8 Ethane 9 Ethylene 16 Acetylene Channel 2: CP-PoraPlot U
57 Refinery Gas Analysis on a Quad MicroGC Channel 3: Al 2 O 3 Peak Identification 16 Acetylene 18 1-Butene 10 Propane 19 iso-butene 12 Propylene 20 cis-2-butene 13 iso-butane 21 iso-pentane 14 n-butane 22 n-pentane 15 Propadiene 23 1,3-Butadiene 17 trans-2-butene 24 Propyne 1 6 Peak Identification 21 iso-pentane 22 n-pentane 26 C6+ (e.g. n-hexane) Channel 4: CP-Sil 5 CB
58 Refinery Gas Analysis A complete range of refinery gas analysis solutions Easy to operate, powerful GC solutions Comprehensive single-vendor solution
59 The Agilent 490 MicroGC G3581A and G3582A EZReporter for calorific value / BTU calculations
60 EZReporter overview Advanced Post-run Reporting and Analysis for biogas, natural gas and refinery gas: Multi-channel normalization and reporting, flexible text export, result monitoring, trend plotting, and alarming Standard GPA/ASTM/ISO natural gas analysis calculations and reporting
61 Ordering Info and Compatibility EZReporter is available for both made-to-order 490 MicroGC (G3581A) and MicroGC based analyzers (G3582A) For both part numbers use opt# 105 Package includes: CD-Rom with EZReporter Software and associated manuals Software registration code Product description EZReporter for calorific value / BTU calculations Compatible with Agilent EZChrom , Agilent OpenLAB CDS EZChrom Edition and Agilent OpenLAB CDS ChemStation Edition Supported standards GPA ASTM D (2003) ISO 6976 (1995)
62 EZReporter Key Features Allows completely automated post-run processing of data Multi-channel Reporting: Results from multiple MicroGC channels are combined into a single report with both raw and normalized amounts (normalized across all channels) displayed. Custom Calculations: Create custom formulas using MicroGC component results and other calculated results (ratios, sums, differences, engineering calculations, etc.) Data Export: Results can be exported to a text file for transfer to a Laboratory Information Management System (LIMS), Process Control System, or Microsoft Excel. The format of the text file can be customized easily using EZReporter s flexible Export Templates.
63 Alarming and Trend Monitoring Monitor Important Results with High/Low Alarms And Trend / History Plots
64 Natural Gas/Refinery Gas Analysis Calculations Standard GPA / ASTM / ISO Calculations: Calculates Dry/Saturated/Wet Superior/Inferior Calorific Value, Real Relative Density, Gas Compressibility factor, GPM value, Wobbe Index, etc. using GPA and ASTM D (2003), ISO 6976 standard calculations. Also supports GPA 2186 and GPA 2177 Natural Gas Liquids/extended reporting. Physical Properties can be Easily Customized: The component list and associated physical properties completely customizable by the end user Standard component physical property tables are provided for the GPA and GPA Standards, ASTM D3588, GPSA Engineering Data Book (12th Edition, 2004), GPA TP-17, and ISO 6976 for the different combustion and metering temperatures.
65 EZReporter Reporting Options Print report automatically to the default printer at the end of the run Save PDF report automatically to a userspecified folder at the end of the run Export results automatically to a text file at the end of the run
66 For genuinely better analytical performance, the Agilent 490 Micro GC gives you the results you need in seconds The Agilent 490 MicroGC features: More data generation in less time for faster, better business decisions Compact dimensions making it easily transportable Modular and flexible Easy to operate without special training or skills Learn more:
67 64
68 The 490 MicroGC looks nice, but I m not looking to lease anything. Why should I call Quantum Analytics? 65
69 Quantum Analytics Solutions The 490 MicroGC looks nice, but I m not looking to lease anything. Why should I call Quantum Analytics? Quantum can help by providing the right solution for your lab. Since we have multiple solutions for addressing gas analysis, we can help explain the advantages, and more importantly, the disadvantages, of each analytical technique. 66
70 Quantum Analytics Solutions How do I know that the MicroGC is the right instrument for my analysis? Quantum can run your samples BEFORE you buy the system, to be sure that the MicroGC is the correct option. The demo 490 MicroGC that will be located in the Quantum Technical Center will be a 4 channel GC with Mole Sieve 5A, Porous Polymer U, Alumina and a CP-Sil 5 modules. On this configuration, and by using different carrier gases, temperature and pressure options, we should be able to run the vast majority of gas analyses that the 490 MicroGC is capable of running. 67
71 Quantum Analytics Solutions I like the idea of those Standard Analyzers, except I want the system configured differently. Is that possible? Quantum can provide a complete analyzertype solution. Even if the analysis in not one of the standard Agilent configurations. Quantum can provide the correct configuration, a method built specifically for your analysis, checked out on your standards and samples. Training can also be provided in our Tech Center or at your location. 68
72 Quantum Analytics Solutions I m still not sure about the MicroGC. If the 490 MicroGC is not the solution, we can help guide you to the correct solution. We at Quantum want to be your gas phase solution provider. We have multiple solutions from multiple vendors to help you make the right decision. 69
73
Pilot Gasifier Producer Gas Analysis and Measurement Arrangements in. University of Applied Sciences
Pilot Gasifier Producer Gas Analysis and Measurement Arrangements in Sievi Laboratory Kari Pieniniemi, Researcher, Centria University of Applied Sciences 1 2 MEASURING LINE AT SIEVI LABORATORY 3 MEASURING
Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward
Chemical Analysis Natural Gas Analyzer A Family of optimized GC Solutions think forward Gas Chromatography Bruker Natural Gas Analyzers Natural gas is bought and sold as a bulk commodity with price based
BTU ANALYSIS USING A GAS CHROMATOGRAPH
BTU ANALYSIS USING A GAS CHROMATOGRAPH By Joseph E. Landes Southern Petroleum Laboratories, Inc. Technical Director Hydrocarbon and Field Services 8820 Interchange Drive Houston, Texas 77054 Introduction
PLOT Columns. Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative
PLOT Columns Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative PLOT Column Selection 93 Features & Benefits of Restek PLOT Columns Features
Chromatograph Maintenance and Troubleshooting Class # 5050
Chromatograph Maintenance and Troubleshooting Class # 5050 Shane Hale Business Development Manager Emerson Process Management Gas Chromatographs Division 5650 Brittmoore Drive Houston, TX 77041 USA Introduction
Transformer Oil Gas Analysis
Get on the Analyzer FAST TRACK Transformer Oil Gas Analysis Helping customers protect the environment! 1 Why Analyzers Value to Customers Alleviates Resource Pressure Facilitates Configuration Use Advanced
Process Instrumentation
Process Instrumentation Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Process Gas Chromatography Features of Process Chromatographs Agilent 7890A
ADVANCEMENTS IN MICRO GAS CHROMATOGRAPHY (GC)
ADVANCEMENTS IN MICRO GAS CHROMATOGRAPHY (GC) 1 Fast Analysis of C1 to C8 hydrocarbons for mud logging applications within 2 minutes using a temperature programmable Micro GC Fusion NEN GAS2015 Debbie
Get the Right GC for Your Industry
Get the Right GC for Your Industry Shimadzu was founded on the basis of "Technology for Science" and we continue to take the initiative in the analytical technology industry. From our absorption spectrophotometers
EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer. HT3 Application Note.
EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer HT3 Application Note Introduction The analysis of dissolved gases in ground water is important in
Fiscal Measurement Natural Gas
White Paper FSG-WP-0012 February 2014 Fiscal Measurement Natural Gas Fiscal Measurement How much? Fiscal Measurement must not be confused with Custody Transfer; in fact, fiscal measurement is a more general
CHROMOCTANE O N LINE ANALYZER
GECIL Process GT instruments CHROMOCTANE O N LINE ANALYZER ASTM D6733 DHA and RON and MON on line GC for Reformer unit Automatic Chromatographic system for analysis of naphta feeds and reforming gasolines
Process gas chromatographs. Measurement made easy. Compliance Solutions for 40CFR60 Subpart Ja
Process gas chromatographs. Measurement made easy Compliance Solutions for 40CFR60 Subpart Ja Introduction ABB offers a proven analytical solution to completely meet your Refinery Flare Monitoring requirements
How To Run A Gas Plant
MATHESON Petrochemical Industry Program for Specialty Gas Supply MATHESON Petrochemical Industry Program for Specialty Gas Supply MATHESON is a single source for industrial, medical, specialty, and electronics
Natural Gas Processing Solutions Using the 700XA Gas Chromatograph
Application Note Oil & Gas Natural Gas Processing Solutions Using the 700XA Gas Chromatograph Optimizing the efficiency and profitability of a natural gas processing plant requires responding to the changing
Online Infrared Flue Gas Analyzer Gasboard 3000
Online Infrared Flue Gas Analyzer Gasboard 3000 O 2 CO CO2 SO 2 NO NO x Use of measurement methods Proprietary Infrared NDIR Detectors - Micro-flow in ppm range: CO, NO, SO2, CO2 - Dual beam in % volume
Fundamentals of Gas Chromatography
Application Note Oil & Gas Fundamentals of Gas Chromatography Figure 1 - The Function Components of a Gas Chromatograph Process Line Sample System Chromatograph Oven GC Controller Probe Sample Return Slip
#5 - MUTE YOUR PHONE Upgrading your Lab to Windows 7? Server 2008?
#5 - MUTE YOUR PHONE Upgrading your Lab to Windows 7? Server 2008? Steve Miller Agilent Technologies Informatics Specialist Agenda What is OpenLAB? What are the products? What is the new Architecture?
On-line Dissolved Gas Analysis
On-line Dissolved Gas Analysis accord. to IEC 567/ASTM 3612 Online-Monitoring of transformers Automatic on-line analysis of 11 gases The analysis is done in 2 steps with high selectivity and accuracy fully
Siemens AG, 2008. Case Study December 2008
Siemens AG, 2008 Process Analytics throughout the entire natural gas pipeline supply chain Case Study December 2008 Natural Gas (NG) Monitoring NG during pipeline transmission Natural Gas is a vital component
Micro Motion 3098 Gas Specific Gravity Meter
Product Data Sheet PS-001161, Rev. D April 2013 Micro Motion 3098 Gas Specific Gravity Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.
Danalyzer Model 700 Gas Chromatograph
Danalyzer Model 700 Gas Chromatograph Page 1 www.daniel.com Danalyzer Model 700 Gas Chromatograph Danalyzer Model 700 Gas Chromatographs offer the broadest range of analysis options available today in
Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000
IMR 5000 Continuous Flue Gas Monitoring System The IMR 5000 is state-of-the-art continuous flue-gas monitoring system, and is designed for a wide variety of flue-gas monitoring applications. The IMR 5000
1. Standard conditions are 29.92 in. Hg (760 mm Hg, 14.696 psia) and 68 F (20 C).
INTRODUCTION Emission Monitoring Inc. DETERMINING F-FACTORS FROM GAS CHROMATOGRAPHIC ANALYSES Roger T. Shigehara Emission Monitoring Incorporated Howard F. Schiff TRC Environmental Corporation EPA Method
1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.
Standard Method for Analysis of Benzene and Toluene Content in Hydrocarbon Waxes by Headspace Gas Chromatography EWF METHOD 002/03 (Version 1 Reviewed 2015) 1 Scope 1.1 This test method covers the qualitative
23 The Thermal Conductivity Detector
23 The Thermal Conductivity Detector General Information TCD pneumatics Conditions that prevent the detector from operating Filament passivation Carrier, reference, and makeup gas Negative polarity Analyzing
RECON-4 Portable Multi-gas Detector Software Manual
ENMET Corporation PO Box 979 Ann Arbor, MI 48106-0979 www.enmet.com RECON-4 Portable Multi-gas Detector Software Manual Version:HW091211001 Manual Part Number 80006-034 January, 2011 Brief Introduction
Calculate Available Heat for Natural Gas Fuel For Industrial Heating Equipment and Boilers
For Industrial Heating Equipment and Boilers Prepared for California Energy Commission (CEC) Prepared By: Southern California Gas Company (A Sempra Energy Utility) E3M Inc. May 2012 i Disclaimer The CEC
AC DHA Solutions. Detailed Hydrocarbon Analysis of Light Petroleum Streams & Light End in Crude Oils. ASTM D 5134, D 6729, D 6730, D 6733 Compliance
AC DHA Solutions Detailed Hydrocarbon Analysis of Light Petroleum Streams & Light End in Crude Oils ASTM D 5134, D 6729, D 6730, D 6733 Compliance Signal Alignment Automated with LineUp TM Tool Compatible
GAS QUALITY CHALLENGES TO SUPPORT DEVELOPING OF NATURAL GAS AS FUEL FOR VEHICLES IN INDONESIA
GAS QUALITY CHALLENGES TO SUPPORT DEVELOPING OF NATURAL GAS AS FUEL FOR VEHICLES IN INDONESIA by EDI WIBOWO and YUSEP K. CARYANA Research and Development Centre for Oil and Gas Technology LEMIGAS Jakarta
Compressor Performance
expertise beyond controls Compressor Performance Advisor (CPA) Software Monitoring compressor performance for the purpose of evaluating compressor productivity and optimizing maintenance intervals is an
Balancing chemical reaction equations (stoichiometry)
Balancing chemical reaction equations (stoichiometry) This worksheet and all related files are licensed under the Creative Commons Attribution License, version 1.0. To view a copy of this license, visit
Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions
Lightweight, compact, ergonomic, safe POLARIS FID Portable TOC Analyser for Stack Emissions The Portable FID for Stack Emissions: lightweight, compact, ergonomic, safe POLARIS FID" analyser realized by
MATHESON REFINERY PROGRAM for Specialty Gas Supply. Experience the MATHESON Commitment to Supply Chain Excellence
MATHESON REFINERY PROGRAM for Specialty Gas Supply MATHESON REFINERY PROGRAM for Specialty Gas Supply MATHESON is a single source for industrial, medical, specialty, and electronics gases as well as gas
Automotive Air Quality Sensors: industrial innovations to protect people s health
Pioneering sensor and detector technology Automotive Air Quality Sensors: industrial innovations to protect people s health COST Action TD1105 3 rd Management Committee Meeting Barcelona, Spain, 21st June
G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method
G8 GALILEO High-End Melt-extraction Analyzer Innovation with Integrity Inert Gas Method Determination of O, N and H The market demands Metals, minerals, and inorganic compound markets demand high-quality
Natural gas chromatograph LNG gas quality testing
Application description AD/2102760-EN Natural gas chromatograph LNG gas quality testing Introduction The portable NGC8206 is a natural gas chromatograph designed for installation in a vehicle or mounted
EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases
Product information EuroFID Total Hydrocarbon Analyzer Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Proven Analyzer Technology Measuring total hydrocarbons
Green Gas Test Centre and Distribution of renewable gases
and Distribution of renewable gases Jan K. Jensen ([email protected]) Danish Gas Technology Centre Nordic Baltic Bioenergy 2013, Oslo Danish Gas Technology Centre Consultancy, R&D, measurements (field and lab.)
Technical Note: Conversion of fuel data to MWh
Technical Note: Conversion of fuel data to MWh Questions 12.2 and 12.3 of the information request ask for energy and fuel inputs to be reported according to standardized units commonly used for measuring
T a b l e o f C o n t e n t s
w w w. g e n t e c h e a l t h c a r e. c o m M E D I C A L M O N I T O R I N G, A L A R M A N D C O N T R O L S Y S T E M S I n t e r n a t i o n a l E d i t i o n Technology for a Better Future Company
Biomethane in Vehicles. October 2008
Biomethane in Vehicles October 2008 1 Gas vehicles A gas vehicles is a vehicle fuelled buy a gaseous fuel not liquid fuel. Seems simple, but not all gasses are the same, and storage methods vary 2 Definitions
Series 2. Air Server. Options for UNITY 2. A robust, cryogen-free solution for round-the-clock on-line air monitoring
Series 2 Air Server Options for UNITY 2 A robust, cryogen-free solution for round-the-clock on-line air monitoring Series 2 Air Server Three- and eight-channel options for UNITY offering round-the-clock
Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors
Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors www.static-control.in 1 Introduction The detection or monitoring of flue gases and or hazardous gases has been a complex subject
Gas Separations: A Comparison of GasPro and Aluminum Oxide PLOT Columns for the Separation of Highly Volatile Compounds
Gas Separations: Comparison of GasPro and luminum Oxide PLOT Columns for the Separation of Highly Volatile Compounds Daniel W. rmstrong* Department of Chemistry, University of Missouri-Rolla, Rolla, MO
Question Bank Organic Chemistry-I
Question Bank Organic Chemistry-I 1. (a) What do you understand by the following terms : (i) Organic chemistry (ii) Organic compounds (iii) Catenation? [3] (b) Why are there very large number of organic
TRL-onlineTOC Monitor is designed for monitoring carbon content in
TRL-onlineTOC Online TOC Monitor TRL-onlineTOC Monitor is designed for monitoring carbon content in Industrial process water To control and monitor different processes where water is used for heating or
COMBUSTION. In order to operate a heat engine we need a hot source together with a cold sink
COMBUSTION In order to operate a heat engine we need a hot source together with a cold sink Occasionally these occur together in nature eg:- geothermal sites or solar powered engines, but usually the heat
IBP 2778_10 HIGH EFFICIENCY ON CO2 REMOVAL IN NATURAL GAS WITH UCARSOL SOLVENTS Thiago V. Alonso 1. Abstract. 1. Introduction
IBP 2778_10 HIGH EFFICIENCY ON CO2 REMOVAL IN NATURAL GAS WITH UCARSOL SOLVENTS Thiago V. Alonso 1 Copyright 2010, Brazilian Petroleum, Gas and Biofuels Institute - IBP This Technical Paper was prepared
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
API Marine. BMS Presentation. Ballast Measurement Systems
API Marine BMS Presentation Ballast Measurement Systems BMS4 Typical Configuration BMS4 Typical Configuration BMS4 Extended Configuration BMS4 System (24 tanks) Air regulator Terminal block Drain/Air Filter
Continuous flow direct water heating for potable hot water
Continuous flow direct water heating for potable hot water An independently produced White Paper for Rinnai UK 2013 www.rinnaiuk.com In the 35 years since direct hot water systems entered the UK commercial
ABSTRACT INTRODUCTION
Infrared Technology for Fail-To-Safe Hydrocarbon Gas Detection Authors: Dr. Shankar Baliga is Manager of Research & Development at General Monitors. He has a Ph.D. in Physics from Ohio State University
The testo 340 What makes it The Ultimate Combustion Tuner?
The testo 340 What makes it The Ultimate Combustion Tuner? Zeichen setzen für die Zukunft Design 2/27 Specification 4 Gas Analyzer- CO,NO,NO2 or SO2 Compact Tough Plug n Play Sensor w/ NEW Replicable Interference
Bringing Innovations to Standards AC Analytical Controls by PAC All In One Biodiesel Analyzer
Bringing Innovations to Standards AC Analytical Controls by PAC All In One Biodiesel Analyzer www.paclp.com Background Biodiesel offers an alternative to fossil diesel fuel & contributes to the reduction
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
Process Gas Chromatograph PGC 9000 VC
Process Gas Chromatograph PGC 9000 VC PRODUCT INFORMATION Serving the Gas Industry Worldwide Fields of application and method of operations 2 Fields of application The PGC 9000 VC process gas chromatograph
Gulf Coast Conference Prepared by: A. Coderre (Clearstone Engineering Ltd)
APPLICATIONS OF FAST TRANSPORTABLE CHROMATOGRAPHY Gulf Coast Conference Prepared by: A. Coderre (Clearstone Engineering Ltd) Introduction: Adam Coderre M.A.Sc., Mechanical Engineering Specializing in emissions
Gas Chromatography monitors Green House Gas (GHG) emission from flares
Gas Chromatography monitors Green House Gas (GHG) emission from flares International regulations increasingly call for on-line monitoring of Green House Gas emissions from flare stacks Flaring produces
Trace Gas Exchange Measurements with Standard Infrared Analyzers
Practical Environmental Measurement Methods Trace Gas Exchange Measurements with Standard Infrared Analyzers Last change of document: February 23, 2007 Supervisor: Charles Robert Room no: S 4381 ph: 4352
Tracer Detection Systems
Tracer Detection Systems WASSON ECE Engineered Solutions, Guaranteed Results. Wasson-ECE Tracer Analysis System The industry standard for low level perfluoronated tracer analysis. Tracer tagging technology
Gas Chromatography monitors Green House Gas (GHG) emission from flares
Process Analytics Gas Chromatography monitors Green House Gas (GHG) emission from flares International regulations increasingly call for on-line monitoring of Green House Gas emissions from flare stacks
Crude Assay Report. Crude Oil sample marked. "AL SHAHEEN CRUDE OIL" dated 10th April 2006. On Behalf Of. Maersk Oil Qatar AS
Crude Assay Report on Crude Oil sample marked "AL SHAHEEN CRUDE OIL" dated 10th April 2006 On Behalf Of Maersk Oil Qatar AS With compliments Intertek Caleb Brett, Fujairah Caleb Brett Fujairah Fujairah
Natural Gas Information Contents
Natural Gas Information Contents What is natural gas Natural Gas Components Physical Properties of Natural Gas Different Forms of Natural Gas The Use of Natural Gas Co-generation System Natural Gas and
Blending Fuel Gas to Optimize use of Off-Spec Natural Gas
Blending Fuel Gas to Optimize use of Off-Spec Natural Gas AUTHORS Mike Segers, P.E. Hurst Technologies Roy Sanchez PSEG Texas Paul Cannon Hurst Technologies Carlos Gutierrez PSEG Texas Bob Binkowski, P.E.
Gas Measurement and Analysis
Gas Measurement and Analysis A powerful tool supporting enterprise financials, decision making, and the global environment February 2010 / White paper Make the most of your energy SM Summary Executive
Petrochemical Industry Ethylene Plant
Petrochemical Industry Ethylene Plant Application note The Ethylene Plant provides the base feedstock for a number of critical products used throughout the petrochemical industry. Compounds ranging from
The Sievers 900 Series TOC Analyzers
GE Water & Process Technologies Analytical Instruments The Sievers 900 Series TOC Analyzers imagination at work Delivering Next-Generation Ease of Use, Productivity, and Reliability The Sievers* 900 Series
1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;
1/11 CO2 DOSAGE SYSTEMS CO2 dosage system consists of following parts; 1 - O2 trim system with micro processing burner (automatic combustion monitoring), 2 - Other components of O2 trim system, 3 - CO2
CHAPTER 7 THE DEHYDRATION AND SWEETENING OF NATURAL GAS
CHAPTER 7 THE DEHYDRATION AND SWEETENING OF NATURAL GAS Natural gases either from natural production or storage reservoirs contain water, which condense and form solid gas hydrates to block pipeline flow
Micro GC Fusion Pre-Installation Checklist
Site Preparation Proper site preparation prior to installing is very important. Contact INFICON (www.inficon.com) with any questions regarding site preparation. NOTE: Checkboxes ( ) identify hardware that
The photoionization detector (PID) utilizes ultraviolet
Chapter 6 Photoionization Detectors The photoionization detector (PID) utilizes ultraviolet light to ionize gas molecules, and is commonly employed in the detection of volatile organic compounds (VOCs).
N O T E S. Environmental Forensics. Identification of Natural Gas Sources using Geochemical Forensic Tools. Dispute Scenarios
Environmental Forensics N O T E S V o l u m e 2 9 Identification of Natural Gas Sources using Geochemical Forensic Tools By Paul Boehm, Ph.D. and Tarek Saba, Ph.D. F o r m o r e i n f o r m a t i o n o
Facts about gas physical properties
Facts about gas physical properties Gas as fuel for propulsion of ships status and perspectives Ingeniørhuset, 3. March 2008 By Asger Myken, DONG Energy DONG Energy 2 Agenda Basic information on gas types
AUTOMATIC LPG BOOKING, LEAKAGE DETECTION AND A REAL TIME LPG MEASUREMENT MONITORING SYSTEM
AUTOMATIC LPG BOOKING, LEAKAGE DETECTION AND A REAL TIME LPG MEASUREMENT MONITORING SYSTEM R.Padmapriya, E.Kamini, [email protected],[email protected], IV Year Electronics and Communication Engineering,
Comparative Economic Investigation Options for Liquefied Petroleum Gas Production from Natural Gas Liquids
American Journal of Chemical Engineering 2015; 3(2-1): 55-69 Published online June 29, 2015 (http://www.sciencepublishinggroup.com/j/ajche) doi: 10.11648/j.ajche.s.2015030201.17 ISSN: 2330-8605 (Print);
COMPRESSED NATURAL GAS (CNG) UTILIZATION POLICY TO IMPROVE URBAN AIR QUALITY by EDI WIBOWO and YUSEP K. CARYANA
COMPRESSED NATURAL GAS (CNG) UTILIZATION POLICY TO IMPROVE URBAN AIR QUALITY by EDI WIBOWO and YUSEP K. CARYANA Research and Development Centre for Oil and Gas Technology LEMIGAS Jakarta 12230, Indonesia.
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
Addressing the World Helium Shortage For Gas Chromatography
Addressing the World Helium Shortage For Gas Chromatography Helium Conservation and Converting GC Methods to Nitrogen and Hydrogen Carrier Gas James D. McCurry, Ph.D. Senior Scientist Agilent Technologies
GC/MS Considerations for Fracking Gases and Water. Dr. Harold McNair Virginia Tech Blacksburg, VA. [email protected]
GC/MS Considerations for Fracking Gases and Water Dr. Harold McNair Virginia Tech Blacksburg, VA. [email protected] 1 Outline What is fracking? Energy, Economics, Environmental Factors Chromatographic Considerations
Thermal Mass Flow Meters
Thermal Mass Flow Meters for Greenhouse Gas Emissions Monitoring Natural Gas Measurement for Emissions Calculations Flare Gas Monitoring Vent Gas Monitoring Biogas and Digester Gas Monitoring Landfill
SYNSPEC GC s ALPHA 115 and ALPHA 116
SYNSPEC GC s ALPHA 115 and ALPHA 116 Methane/TotalNonMethaneHydroCarbons Operator manual Version January 2010 Synspec b.v. De Deimten 1 9747 AV Groningen Nederland [email protected] CONTENTS CONTENTS...
FORMATION DAMAGE AND WELL TREATMENT SYSTEM
FORMATION DAMAGE AND WELL TREATMENT SYSTEM FDWTS-10K Includes ability to test Liquid Permeability & Gas Permeability Fines migration & critical velocity Static Filtration Drilling mud invasion evaluation
EnAlgae SOP: Biogas analysis
Table of content 1. PURPOSE... 2 2. PRINCIPLE... 2 3. REQUIREMENTS... 3 3.1. EQUIPMENT AND MATERIALS... 3 3.2. REAGENTS... 3 3.3. PREPARATION OF MEASUREMENT... 3 4. PROCEDURE... 4 4.1. SAMPLE MEASUREMENT...
F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems
F ox W hi t e Paper Reduce Energy Costs and Enhance Emissions Monitoring Systems A Technical White Paper from Fox Thermal Instruments Rich Cada, VP Sales & Marketing, Fox Thermal Instruments, Inc. 399
CNG, LNG, and Other Fuels from Landfill Gas ---Prospects for Future Development----
CNG, LNG, and Other Fuels from Landfill Gas ---Prospects for Future Development---- California Biomass Collaborative 4 th Annual Forum March 28, 2007 Sacramento, California Patrick Sullivan SCS Engineers
Fast Continuous Online Analysis of VOCs in Ambient Air using Agilent 5975T LTM GC/MSD and Markes TD
Fast Continuous Online Analysis of VOCs in Ambient Air using Agilent 5975T LTM GC/MSD and Markes TD Application Note Environmental Author Xiaohua Li Agilent Technologies (Shanghai) Co., Ltd. 412 Ying Lun
Fluid & Gas Properties
Fluid & Gas Properties FLUID DENSITY Density is the ratio of mass to volume. In English, units density is expressed in pounds mass/cubic foot (lbm/ft 3 ). The symbol for density is ρ. Density is usually
MB3600-HP12 / Measurement & Analytics. Laboratory FT-NIR Heavy Oils Analyzer Crude oil, fuel oil, heavy oil upgrader unit feeds
MB3600-HP12 / Measurement & Analytics Laboratory FT-NIR Heavy Oils Analyzer Crude oil, fuel oil, heavy oil upgrader unit feeds Adapted for crude oil, fuel oil and heavy oil upgrader unit feed applications
The software solution to complete your flow monitoring program
The software solution to complete your flow monitoring program Flowlink 5.1 software is the central point of your flow data management program. With this software you can: Configure Isco equipment on-site
PolyGard Carbon Monoxide CO Transmitter ADTX3 1110
PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 DESCRIPTION CO transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air
ANNEX I GAS MEASUREMENTS AND TESTING AT THE DELIVERY POINT. Table of Contents
ANNEX I GAS MEASUREMENTS AND TESTING AT THE DELIVERY POINT Table of Contents 1. Purpose... 1 2. Scope... 1 3. Definitions, Symbols and Abbreviations... 2 4 General... 6 5. Natural Gas Volumetric Flow Measurement...
The Ambient Air Monitoring System
The Ambient Air Monitoring System 1.0 Introduction: The Ambient Air Monitoring System (AAMS) can measure a range of toxic and flammable gases, particulate matter, meteorological and environmental parameters
Emerson Gas Chromatograph Solutions For Natural Gas Transmission Applications. Superior Performance, Repeatability, and Reliability
Emerson Gas Chromatograph Solutions For Natural Gas Transmission Applications Superior Performance, Repeatability, and Reliability Struggling to Reduce Costs While Meeting Tighter Energy Measuremen What
Dew-Point Measurement Solutions
Dew-Point Measurement Solutions www.michell.com Dew-Point Measurement Solutions Special Features No downtime Michell Instruments offers a unique sensor exchange programme, which means that you will never
HOW TO SIZE A PRESSURE REGULATOR
CHOOSING THE CORRECT REGULATOR HOW TO SIZE A PRESSURE REGULATOR In order to choose the correct regulator the following information is needed: - Function: Pressure reducing or backpressure control? - Pressure:
The Use of Hydrogen Carrier Gas for GC/MS
Technical Note The Use of Hydrogen Carrier Gas for GC/MS Gas Chromatography/ Mass Spectrometry Highlights Guidelines that can mitigate dangers and leverage benefits of using hydrogen Key safety factors
Thermal Conductivity Detector
Thermal Conductivity Detector Troubleshooting Tips The thermal conductivity detector (TCD) detects the difference in thermal conductivity between column effluent flow (carrier gas + sample components)
TECHNIQUES FOR NATURAL GAS SAMPLING A DISCUSSION OF FIELD METHODS FOR OBTAINING SPOT SAMPLES. Randall Messman SW Regional Sales Manager
TECHNIQUES FOR NATURAL GAS SAMPLING A DISCUSSION OF FIELD METHODS FOR OBTAINING SPOT SAMPLES Randall Messman SW Regional Sales Manager PGI International 16101 Vallen Drive Houston, TX 77041 Purpose Natural