FORMATION DAMAGE AND WELL TREATMENT SYSTEM
|
|
|
- Marian Curtis
- 10 years ago
- Views:
Transcription
1 FORMATION DAMAGE AND WELL TREATMENT SYSTEM FDWTS-10K Includes ability to test Liquid Permeability & Gas Permeability Fines migration & critical velocity Static Filtration Drilling mud invasion evaluation Formation stimulation Not just products... solutions.
2 Description The PMI Advanced Formation Damage & Well Treatment System is designed to provide accurate data while being simple to use. It is easy to setup, use, and disassemble. The permeameter comes in a case designed to keep the instrument safe while being simple to transport from one location to the next in the field. The markings for the air tube and the water reservoir are clear and easy to read for simple data recording. The provided data booklet has a straight forward layout to help the technicians take fast and accurate readings, calculations, useful notes and other important information. Con ning Pressure Pump Leak- Core Holder Circular Mud Pump Main Software Screen Humidi er Gas Brine Brine Brine Oil BPR Acid BPR Cylinder Gas Gas Separator r Meter Scale Posi ve Displacement Pump Scale Machine Scematic Diagram Manual Test Screen
3 The PMI Advanced Formation Damage & Well Treatment System, Model FDWTS-10K is designed to study formation damage in reservoir condition. The FDWTS-10K is capable to perform proven measurement of : Applications Formation Damage (By mud and Frac fluids, EOR processes) Gas & Liquid Permeability Core Flood Residual Fluid Saturation Relative Permeability, Amott wettability and Core compressibility, etc
4 Procedure Saturate core sample with Formation brine Measure liquid Permeability in reverse direction Flood the Core Sample with Oil (or gas) till Swi Measure effective permeability to oil (or gas) in reverse direction Flow acid across the upstream end face of the core sample to wash the mud cake Flow mud across the upstream end face of the core sample to form a mud cake Flood the core sample with oil (or gas) in reverse direction again to remove all mud filtrates Measure effective permeability to oil (or gas) in reverse direction to obtain the permeability value after the core Flood the core sample with acid in forward direction Flood the core sample with oil (or gas) in reverse direction again to remove acid traces. Measure effective permeability to oil (or gas) in reverse direction to obtain the permeability value after the core acidizing.
5 Instrument The PMI Advanced Formation Damage & Well Treatment System is equipped with a humidifying system that is able to regulate and control the humidity of various gases. The dry gas is split into two streams. One stream will remain dry while the other stream will pass through a humidifier vessel to become humid. The two streams will then pass through flow controllers and join back up in one stream. This stream will have the humidity measured so that the software can control the dry-wet ratio to achieve the desired humidity. The sample cell is designed to hold rock cores with 1" and 1.5" diameters and 1" to 6" lengths. The whole instrument is designed to be corrosion resistant, withstand pressures up to 10000PSI, and temperatures up to 180º C. TESTING CAPABILITIES This system is able to perform the following tests Liquid Permeability & Gas Permeability Fines migration & critical velocity Static Filtration Drilling mud invasion evaluation Formation stimulation
6 Specifications Maximum pressure of confining pressure pump: psi Maximum pressure of pore pressure: 6000 psi (LS class pump) Temperature: Ambient to 180ºC Maximum Confining pressure: 10,000 psi (High Pressure Available) Maximum pore pressure: 6,000 psi (High Pressure Available) Core diameter: 1.0" and 1.5" standard (Other Option Available) Core length: 1" to 4" maximum (Other Option Available ) Confining pressure controller: Automatic,manual, pneumatic Material: Stainless Steel, Titanium, Hastelloy, iton, Teflon Forward and Backward Injection Capability Automatic Confining Pressure Controller Piston accumulators: Included Back pressure regulator: Included Humidifier: Capacity: 800 ml Max Pressure: 300 psi Scale: 500 g Gas separator capacity: 250 ml System flow rate: l/hour KEY SPECS Pulsation-free pumping system Automatic confining pressure controller Superior core holder design simplifies operation and reduces operator work load. Advanced Software module allows the user to predefine test sequences that can be saved for future use
7 Flow in CC/SEC. Flow in CC/SEC. Key Features FLOW RATE S PRESSURE PRESSURE (PSI) Gas Permeability FLOW RATE S PRESSURE PRESSURE (PSI) Liquid Permeability Advanced fully computer controlled system that allows the operation for both automatic and manual modes where can provide precise monitoring and data acquisition Capable of flooding core sample with reservoir fluids at reservoir conditions, including oil, brine, and polymers, etc. Automated temperature control and Automated pressure control Machine made out of corrosion resistant materials Bypass valves for user protection- All controlled systems and components are fail safe The PMI Advanced Formation Damage & Well Treatment System can be used to study formation damage by mud and frac fluids, EOR Processes, General Core absolute and relative permeability testing, wettability etc. The standard configuration allow for liquid/liquid at constant flow rate and liquid /gas at constant pressure rate. The PMI Advanced Formation Damage & Well Treatment System designed is very user friendly both mechanically and in its software interface. This system can be used to study steady or unsteady state relative permeability for liquid/gas at reservoir conditions. Automated humidity control for gases Heating method is provided by oven with digital temperature control. All other valves and other parts such as accumulators are inside. Other parts that do not have to take the heat such as pumps etc. are placed in a cabinet behind the furnace and accessible from behind for service. Simple sample setup and All parts for machine contained within single cabinet Forward and Backward injection capability Downstream wet gas meter for accuracy of gas flow Fraction collector Simple reporting software automatically performs calculations from data Types of Samples: Rock Cores (1inch to 1.5inch diameter, 1" to 6" length) Reported alues: Permeability, Differential pressure over time, Humidity over time Inlet and Outlet pressure over time, Humidity over time, Temperature over time
8 Software The system is controlled through most up-to-date version of Microsoft Windows based software Exporting graphic files to window based word/excel processing files for report generation. Capable to be programmed for automatic repeat measurements or for data acquisition under user selected tolerances. Graphic presentation of the data to be evaluated and analysis results. Provision for off-line data processing. Integrated detailed help system. Calibration routines able to be controlled by PMI s software. PMI Software has built in features for automatic start up and shut down procedures, real time display of the sample analysis progress Machine Configuration Screen PMI Software includes all the data handling features including user defined report generation, data, figures & ability to export to spreadsheets, offline data processing, etc. Auto Test-Step Data Filling Auto Test-Step Sample Chamber Temperature filling Auto Test-Data Recording
9 Unique Features Leak-off core holder A circulating pump to flow mud across the upstream end face of the core sample. One displacement pump connected to an accumulators system via cross connector to flow brine, oil, or acids through the core sample one at a time. Liquids in accumulators are in pressure equilibrium allowing for liquid changes to be conducted under dynamic flow without disturbing the system pressure equilibria. Three brine accumulators to perform clay sensitivity tests. A nitrogen cylinder to flow gas through a gas humidifier into the core sample. Gas seperator and gas flow meter to measure gas permeability in reverse direction. Two weighing scales to measure liquid permeability in reverse direction, and mud filtrates. Two pressure taps to measure the pressure drop along the core sample. SALES & SERICE Our sales team is dedicated to helping our customers find whichmachine is right for their situation. We also offer custom machines for customers with unique needs. To find out what we can do for you, contact us. We are committed to customer support including specific service products, short response times & customer specific solutions. To quickly & flexibly meet our customer's requirement, we offer a comprehensive range of services. Customize your Machine Today! Disclaimer: *Design Subject to change without prior notice.
10 The most advanced, accurate, easy to use and reproducible Formation Damage Systems in the world. Celebrating 35 years of solutions 20 Dutch Mill Rd, Ithaca, NY 14850, USA Toll Free (US & Canada): TALK-PMI ( ) Phone: Fax: PROUDLY MADE IN USA
Fundamentals of Mass Flow Control
Fundamentals of Mass Flow Control Critical Terminology and Operation Principles for Gas and Liquid MFCs A mass flow controller (MFC) is a closed-loop device that sets, measures, and controls the flow of
Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9
Pumping Systems, Intensifiers, Gas Boosters and High Pressure Generators High Pressure Equipment Company produces a number of components and systems for general industrial, elevated pressure applications.
RITTER Multiple Sonic Nozzle Calibration System
RITTER Multiple Sonic Nozzle Calibration System »Wouldn t it be great to eliminate doubtful measurement results by using proven measurement technology? Providing the most precise results ensures and increases
KNC Model 3666 Automatic Pressure Calibration System
KNC Model 3666 Automatic Pressure Calibration System Product Description The Model 3666 Automatic Pressure Calibration (APC) System by King Nutronics Corporation is a portable secondary standards laboratory
COMBIMASS. Technical Data COMBIMASS eco-bio +
COMBIMASS Technical Data THE SYSTEM COMBIMASS The field transmitters of the COMBIMASS eco series are suitable for gas flow measurement and cover a wide range of different applications. The instruments
Measurement & Analytics. VIS Multiphase Flow Meter High gas content applications solved with no radioactive source - Measurement made easy
Measurement & Analytics VIS Multiphase Flow Meter High gas content applications solved with no radioactive source - Measurement made easy ABB s VIS Multiphase Flow Meter Easy to operate, accurate and fieldproven
Chapter 19 Purging Air from Piping and Vessels in Hydrocarbon Service
BP Lower 48 Onshore Operations Safety Manual Page 4.19 1 Chapter 19 Purging Air from Piping and Vessels in Hydrocarbon Service I. General Requirements A. After motor vehicle accidents and underground excavation
Tadahiro Yasuda. Introduction. Overview of Criterion D200. Feature Article
F e a t u r e A r t i c l e Feature Article Development of a High Accuracy, Fast Response Mass Flow Module Utilizing Pressure Measurement with a Laminar Flow Element (Resistive Element) Criterion D200
Thermostatic expansion valves type TR6 REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Thermostatic expansion valves type REFRIGERATION AND AIR CONDITIONING Technical leaflet Thermostatic expansion valves, type Contents Page Introduction........................................................................................3
HALITE PRECIPITATION AND PERMEABILITY ASSESSMENT DURING SUPERCRITICAL CO 2 CORE FLOOD
SCA2010-18 1/12 HALITE PRECIPITATION AND PERMEABILITY ASSESSMENT DURING SUPERCRITICAL CO 2 CORE FLOOD Y. Wang a, T. Luce a, C. Ishizawa a, M. Shuck a, K. Smith a, H. Ott b, and M. Appel a Shell International
A New Technique Provides Faster Particle Size Analysis at a Lower Cost Compared to Conventional Methods
A New Technique Provides Faster Particle Size Analysis at a Lower Cost Compared to Conventional Methods Howard Sanders and Akshaya Jena Porous Material Inc. Ithaca, NY The technique described here calculates
Why and How we Use Capacity Control
Why and How we Use Capacity Control On refrigeration and air conditioning applications where the load may vary over a wide range, due to lighting, occupancy, product loading, ambient weather variations,
The PMI Advanced. BET SORPTOMETER BET-201-AELC-2OS Not just products...solutions!
The PMI Advanced BET SORPTOMETER BET-201-AELC-2OS Not just products...solutions! DESCRIPTION The Fully automated equipment is intended for measurement of adsorption characteristics of various gases on
User s Manual Laminar Flow Elements
501:440-13 User s Manual Laminar Flow Elements 10920 Madison Avenue Cleveland, Ohio 44102 Tel: 216.281.1100 email:[email protected] Web:www.meriam.com 1 TABLE OF CONTENTS Subject Page Introduction... 3
Gas Custody Transfer Calibration
Gas Custody Transfer Calibration Using multi variable temperature / pressure calibrators for flowmeter calibration 2013 Introduction Gas custody transfer flow computers require special calibration to perform
Application of the Orifice Meter for Accurate Gas Flow Measurement page 1. Application of the Orifice Meter for Accurate Gas Flow Measurement.
Application of the Orifice Meter for Accurate Gas Flow Measurement page 1 DANIEL MEASUREMENT AND CONTROL WHITE PAPER Application of the Orifice Meter for Accurate Gas Flow Measurement www.daniel.com Summary
Any Service Technician Can Fix It A Good Service Technician Can Figure Out What s Wrong With It.
I Dave s Statement If the thermostat calls for cooling, and the furnace fan is running properly, and the coil airflow is adequate, and the condenser fan is running properly, and the condenser airflow is
The Problem. Enhanced Oil Recovery Research. Research Details. www.equilibar.com. For immediate release: June, 2015
For immediate release: June, 2015 Equilibar Plays Key Role in Research of Enhanced Oil Recovery Using Carbonated Water Flooding Dome loaded regulator holds pressure under extreme testing conditions at
COUNTERBALANCE VALVES
COUNTERBALANCE VALVES Introduction They are modulating valves which allow free flow into the actuator and then block the reverse flow until they feel a pilot pressure inversely proportional to the load
Material taken from Fluid Power Circuits and Controls, John S. Cundiff, 2001
Pressure Control Chapter 3 Material taken from Fluid Power Circuits and Controls, John S. Cundiff, 2001 Introduction Pressure control is a key element in the design of any circuit. Used correctly, it can
FCI M180 Series: Custom Engineered Flow and Level Sensors for OEM Applications
FCI M180 Series: Custom Engineered Flow and Level Sensors for OEM Applications Flow Measurement Flow Switches Level Switches Level Interface Switches FCI OEM SERIES Industrial Machinery Chemical Injection
Rosemount Orifice Plate in Wet Gas
00870-0100-4810 January 2006 Page 1 Rosemount Orifice Plate in Wet Gas This paper discusses the phenomenon of wet gas measurement, definitions, and the need to accurately measure this mixture. This paper
Water hammering in fire fighting installation
Water hammering in fire fighting installation Forward One of major problems raised in the fire fighting network installed at Pioneer company for pharmaceutical industry /Sulaymania was the high water hammering
Pressure calibration equipment
Pressure calibration equipment Pressure calibration evolution 1925 Westertoren in Amsterdam 30 meter mercury column (±40 bar) 1950 comparison test pump 21 st century Stiko gas driven differential deadweight
Stack Sampling Stack sampling or source sampling
Stack Monitoring Stack Sampling Stack sampling or source sampling may be defined as a method of collecting representative samples of pollutant laden air/gases at the place of origin of pollutants to determine
Schematic Symbols Chart (Design Hydraulic and Pneumatic circits)
Page 1 of 6 (Home) Symbols / Visit us on: Fluid Power, Automation and Motion Control for all Industries About Us Products Services Catalogs Place an Order Training & Information Contact Us Employee Access
Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE
Waters Corporation Waters 2690/5 USER & TROUBLESHOOTING GUIDE Contents 2690/5 Theory Setup procedures. Troubleshooting the 2690/5 User maintenance of the 2690/5 Spare Parts 2 2690/5 Theory 2690/5 Solvent
ORGANIC SAMPLE PREPARATION
ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,
Testing methods applicable to refrigeration components and systems
Testing methods applicable to refrigeration components and systems Sylvain Quoilin (1)*, Cristian Cuevas (2), Vladut Teodorese (1), Vincent Lemort (1), Jules Hannay (1) and Jean Lebrun (1) (1) University
RGC-IR Remote Gas Calibrator for IR400
Remote Gas Calibrator for IR400 The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing by
CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!
CPX/HT Series REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM High-performance products. Designed for you! COMPRESSED AIR WATER CONTAMINATION Atmospheric air contains water in vapor form in different
Heating Water by Direct Steam Injection
Heating Water by Direct Steam Injection Producing hot water by direct steam injection provides a solution where large volumes of hot water at precise temperatures are required, and where energy and space
Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters
Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters When water is heated, it naturally expands and allowance has to be made for this. Vented water heaters usually
F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems
F ox W hi t e Paper Reduce Energy Costs and Enhance Emissions Monitoring Systems A Technical White Paper from Fox Thermal Instruments Rich Cada, VP Sales & Marketing, Fox Thermal Instruments, Inc. 399
Basic Hydraulics and Pneumatics
Basic Hydraulics and Pneumatics Module 1: Introduction to Pneumatics PREPARED BY IAT Curriculum Unit March 2011 Institute of Applied Technology, 2011 ATM 1122 Basic Hydraulics and Pneumatics Module 1:
PORTER MASS FLOW MEASUREMENT AND CONTROL SYSTEMS
PORTER MASS MEASUREMENT AND CONTROL SYSTEMS PORTER: THE STANDARD OF EXCELLENCE IN MASS Porter Mass Flow products reflect nearly three decades of experience in the design and manufacture of precision instruments
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
World-Class Oil Sampling It is Possible
www.lubecontrol.com.au World-Class Oil Sampling It is Possible Lube Control Pty Ltd Providing lubrication solutions! Unit 5/53 Norfolk Rd, Marion, SA 5043 t: (08) 8298 5563 f: (08) 8298 6253 e: [email protected]
METHOD OF TEST FOR DETERMINATION OF PERMEABILITY OF GRANULAR SOILS
Laboratory Testing Manual Date: 99 06 21 Page 1 of 7 METHOD OF TEST FOR DETERMINATION OF PERMEABILITY OF GRANULAR SOILS 1. SCOPE 1.1 This method covers the determination of the coefficient of permeability
PERMEABILITY TEST. To determine the coefficient of permeability of a soil using constant head method.
PERMEABILITY TEST A. CONSTANT HEAD OBJECTIVE To determine the coefficient of permeability of a soil using constant head method. need and Scope The knowledge of this property is much useful in solving problems
Mass Flow Meter Product Guide
Mass Flow Meter Product Guide 2 thermal Mass technology Kurz Instruments manufactures thermal mass flow meters designed to accurately monitor and measure dry air, dry gas, and wet gas environments. Thermal
HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer
Smart Solutions for Drying Compressed Air Dual Tower Heat Reactivated Desiccant Air Dryer HR Heated HB Blower 800.943.794 www.engineeredairproducts.com Engineered Air Products Moisture in compressed air
400B SERIES DIAPHRAGM PUMP
400B SERIES DIAPHRAGM PUMP In today s agricultural and industrial markets, isn t it good to know that you can rely on one name Sotera to fit your chemical transfer needs? The Sotera 400B Series offers
Mechanical Seal Piping Plans
Mechanical Seal Piping Plans Single Seals plans 01, 02, 03, 11, 13, 14, 21, 23, 31, 32, 41 Dual Seals plans 52, 53A, 53B, 53C, 54, 55 Quench Seals plans 62, 65A, 65B, 66A, 66B Gas Seals plans 72, 74, 75,
The Piping System Model a New Life Cycle Document. Elements of the Piping System Model
Piping System Model as a Life Cycle Document White Paper Introduction When designing piping systems, a variety of documents are created providing the details necessary to design, purchase, build, and test
Step Rate Testing: Determining Fracture Pressure for Injection Wells 2016 UNDERGROUND INJECTION CONTROL CONFERENCE DENVER, CO LEWIS WANDKE, PE
1 Step Rate Testing: Determining Fracture Pressure for Injection Wells 2016 UNDERGROUND INJECTION CONTROL CONFERENCE DENVER, CO LEWIS WANDKE, PE AND KEN COOPER, PE PETROTEK ENGINEERING CORPORATION Overview
Effect of Water Pre-Flush Volumes on Polymer Flooding. Oil Recovery from Sandstone Core Samples. By: Michael Grant
Effect of Water Pre-Flush Volumes on Polymer Flooding Oil Recovery from Sandstone Core Samples By: Michael Grant Submitted in Partial fulfillment of the Master in Petroleum, Oil, And Gas Engineering Program
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
Laminar Flow Elements
Laminar Flow Elements Meriam Laminar Flow Elements (LFEs) are excellent for measuring low gas flow rates from 0.2 SCCM up to 2250 SCFM. They are inherently accurate and repeatable and are calibrated traceable
Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.
ASGMT / Averaging Pitot Tube Flow Measurement Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc. Averaging Pitot Tube Meters Introduction
Adsorption air dryers ADS 1 215
Adsorption air dryers ADS 25 INDUSTRY CUSTOMER SERVICE COMPRESSED AIR AIR INTAKE 20 C 70% UR 760 mm Hg 2 grh 2 O/m 3 AIR PRESSURE 0 bar COOLING SYSTEM 30 C 00% UR 0 bar 2,8 grh 2 O/m 3 A compressor that
HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT
HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT MAXIMATOR GmbH 2 MAXIMATOR has an extensive know-how concerning concept, development, construction and manufacturing of test benches and
UNIVERSITY OF MINNESOTA DULUTH DEPARTMENT OF CHEMICAL ENGINEERING ChE 3211-4211 ABSORPTION OF CARBON DIOXIDE INTO WATER
UNIVERSITY OF MINNESOTA DULUTH DEPARTMENT OF CHEMICAL ENGINEERING ChE 3211-4211 ABSORPTION OF CARBON DIOXIDE INTO WATER OBJECTIVE The objective of this experiment is to determine the equilibrium line,
DEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS
DEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS J J Brasz, Carrier Corporation, Syracuse, NY, 13221, USA [email protected] I K Smith and N Stosic
Pump ED 101. Positive Displacement Pumps. Part I Reciprocating Pumps
Pump ED 101 Positive Displacement Pumps Part I Reciprocating Pumps Joe Evans, Ph.D http://www.pumped101.com There are many pump designs that fall into the positive displacement category but, for the most
Precision Mass Flow Metering For CVD Applications.
Precision Mass Flow Metering For CVD Applications. Ir. H.J. Boer Research Department of Bronkhorst High-Tech B.V. Nijverheidsstraat 1A, 7261 AK Ruurlo The Netherlands. Tel: +31 (0)573 458800 Fax: +31 (0)573
Micro Motion 3098 Gas Specific Gravity Meter
Product Data Sheet PS-001161, Rev. D April 2013 Micro Motion 3098 Gas Specific Gravity Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.
Chapter 10. Flow Rate. Flow Rate. Flow Measurements. The velocity of the flow is described at any
Chapter 10 Flow Measurements Material from Theory and Design for Mechanical Measurements; Figliola, Third Edition Flow Rate Flow rate can be expressed in terms of volume flow rate (volume/time) or mass
WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP
WILROY ATEX Approved HYDRAULICALLY ACTUATED DIAPHRAGM PUMP Williams and Milton Roy have combined technologies to design a pump blending the proven mroy hydraulic by-pass diaphragm design with the Williams
Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1
Fault codes DM1 Industrial engines DC09, DC13, DC16 Marine engines DI09, DI13, DI16 03:10 Issue 5.0 en-gb 1 DM1...3 Abbreviations...3 Fault type identifier...3...4 03:10 Issue 5.0 en-gb 2 DM1 DM1 Fault
Typical Aluminum GFM Mass Flow Meter
MASS FLOW METERS Design Features n Rigid metallic construction. n Maximum pressure of 1000 psig (70 bars). n Leak integrity 1 x 10-9 of helium. n NIST traceable certification. n Built-in tiltable LCD readout.
FLUID FLOW Introduction General Description
FLUID FLOW Introduction Fluid flow is an important part of many processes, including transporting materials from one point to another, mixing of materials, and chemical reactions. In this experiment, you
Redefining Spray Technology
Redefining Spray Technology Macrospray Single-Point Nozzles Macrospray Spider Nozzles Macrospray nozzle technology Improved performance, lower cost Macrospray nozzle technology from Parker Hannifin s Gas
Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard
Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard Introduction SRU s (Sulfur Recovery Units) are critical pieces of equipment in refineries and gas plants. SRUs remove sulfur compounds from certain
CO 2 41.2 MPa (abs) 20 C
comp_02 A CO 2 cartridge is used to propel a small rocket cart. Compressed CO 2, stored at a pressure of 41.2 MPa (abs) and a temperature of 20 C, is expanded through a smoothly contoured converging nozzle
The Fundamentals of Gas Flow Calibration
The Fundamentals of Gas Flow Calibration Application Note Introduction Understanding the fundamentals of gas flow calibration is essential for evaluating calibration systems, estimating the magnitude of
EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL
EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL Issue February 2004 2 TABLE OF CONTENTS SECTION PAGE 1. INTRODUCTION 3 1.1 General 3 1.2 Ceramic Sensing Element 3 1.3 Calibration
Pin & Vee Block Test Machine
Pin & Vee Block Test Machine Picture of the apparatus Used in Standard Test Methods ASTM Standards D 2670, D2626, D3233, D5620 Federal Test Methods FTM-791-3807.1, FTM-791-3812.1 Chrysler Corporation 461-C-84-01,
SWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical
FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters
FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters M-4270/0707, pg. 2 of 29 READ THIS MANUAL COMPLETELY BEFORE ATTEMPTING TO CONNECT OR OPERATE YOUR FLOW SENSOR. FAILURE TO DO SO MAY
Basic Symbols. Lines. Circular. Square. Diamond. Miscellaneous Symbols. -continuous line - flow line. -dashed line - pilot, drain
Airline Hydraulic's Main Page Basic Symbols Lines continuous line flow line dashed line pilot, drain envelope long and short dashes around two or more component symbols. Circular Square Diamond large circle
MB3600-HP12 / Measurement & Analytics. Laboratory FT-NIR Heavy Oils Analyzer Crude oil, fuel oil, heavy oil upgrader unit feeds
MB3600-HP12 / Measurement & Analytics Laboratory FT-NIR Heavy Oils Analyzer Crude oil, fuel oil, heavy oil upgrader unit feeds Adapted for crude oil, fuel oil and heavy oil upgrader unit feed applications
DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING
By Philip Sutter Pick Heaters, Inc. DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING INTRODUCTION Many process plants currently use steam or hot water to heat jacketed devices such as tanks,
ORIFICE PLATES. CONCENTRIC BORE: For standard fluid conditions an Orifice Plate would have a centrally located orifice bore.
SUPERIOR PRODUCTS, INC. 20550 MADISON STREET, TORRANCE, CA 90503 ORIFICE PLATES MANUFACTURING STANDARDS: Superior Products manufactures Orifice Plates in strict accordance with the specifications of: AGA.,
How To Replace A Reverse Osmosis Water Tank
ALL MODELS REVERSE OSMOSIS WITH NONAIRGAP FAUCET 1. Read all instructions carefully before starting installation. 2. Find the cold water line beneath your sink. The cold water is typically on the right.
P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features
P3000 Series Pneumatic Deadweight Testers P3000 Technical Data Features Pressure ranges from Vacuum through 2 000 psi (140 bar) Accuracy better than 0.015 % of reading. (Increased accuracy option of 0.008
VdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01)
VdS Guidelines for water extinguishing systems VdS 2100-09en Requirements and test methods VdS 2100-09en : 2011-05 (01) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,
Mitos P-Pump. product datasheet
product datasheet page Product description 2 Main benefits 3 Why choose the Mitos P-Pump? 3 Closed-loop flow control 4 Product specifications 5 Accessories - overview 6 Mitos P-Pump Basic 7 Mitos P-Pump
HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS
HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS Shiwei William Guan, Ph.D. Vice President, R&D and International Business Madison Chemical Industries Inc. 490
LifeASSURE PFS Series Filter Cartridge Integrity Testing
LifeASSURE PFS Series Filter Cartridge Integrity Testing Introduction Integrity testing is the end user s method of confirming the structural integrity of a membrane filter before and after use. It is
Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur
Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur Lecture No. # 22 Refrigeration System Components: Compressor (Continued)
Daniel. Liquid Control Valves Technical Guide. Technical Guide DAN-LIQ-TG-44-rev0813. DAN-LIQ-TG-44-rev0208. February 2008.
DAN-LIQ-TG-44-rev0208 February 2008 Daniel Liquid Control Valves Technical Guide www.daniel.com Daniel Measurement and Control Theory, Principle of Operation and Applications This brochure has been prepared
LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS
LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS 1. Define an accumulator and explain its function A hydraulic accumulator is a device that stores the potential energy of an incompressible fluid
ETC -SV. Class 0 oil-free compressed air through catalysis
Innovation QUALITy Reliability Worldwide ETC -SV Class 0 oil-free compressed air through catalysis The way to oil-free compressed air The ETC operating principle Through the process of catalytic oxidation,
Penetration tests according to the ISO 11140
Space for 3M Montage Penetration tests according to the ISO 11140 Josephus Paulus Clemens Maria van Doornmalen Gomez Hoyos Outline Purpose penetration tests ETS Alternatives for original Bowie and Dick
Grant Agreement No. 228296 SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme
Grant Agreement No. 228296 SFERA Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME Capacities Specific Programme Research Infrastructures Integrating Activity - Combination of
Air Conditioning & Refrigeration Master Catalog. Catalog CIC-2003-1/USA April 2003
Air Conditioning & Refrigeration Master Catalog Catalog CIC-2003-1/USA April 2003 Table of Contents Table of Contents Service Valves Frontseating Valves... page 115 RB01 Series Ball Valves... page 117
Side-Trak 830/840. Process Gas Mass Flow Meters and Controllers. www.sierrainstruments.com
Process Gas Mass Flow Meters and Controllers Features n Direct monitoring of mass flow eliminates need for ancillary pressure and temperature sensing n Patented straight sensor tube with access ports permits
A Practical Guide to Free Energy Devices
A Practical Guide to Free Energy Devices Part PatE17: Last updated: 24th November 2006 Author: Patrick J. Kelly This is a patent application from Stephen Meyer, brother of the late Stan Meyer. While this
Troubleshooting an Air Conditioning system. R D Holder Eng. Roger D Holder MSME
Troubleshooting an Air Conditioning system R D Holder Eng. Roger D Holder MSME Troubleshooting of an air conditioning system is a step by step procedure. I have found that a 4 step procedure is the best
Vacuum Control. Vacuum Applications. Vacuum Regulators. Vacuum Breakers (Relief Valves) Vacuum Control Devices. Vacuum Terminology
Vacuum Applications Vacuum regulators and breakers are widely used in process plants. Conventional regulators and relief valves might be suitable for service if applied correctly. This section provides
Application Note USTR 805. Steam Sterilization of Pall Filter Assemblies Utilizing Replaceable Filter Cartridges
Application Note USTR 805 Steam Sterilization of Pall Filter Assemblies Utilizing Replaceable Filter Cartridges 0 Table of Contents Table of Contents 1. Important Recommendations...1 1.1 Installation
Chapter 10: Relative Permeability
Chapter 10: 10.1 Introduction and Definition Routine permeability measurements are made with a single fluid filling the pore space. This is seldom the case in the reservoir situation except in water zones.
GAS HANDLING SYSTEMS VACUUM INSTRUMENT CORPORATION
GAS HANDLING SYSTEMS VACUUM INSTRUMENT CORPORATION 2099 Ninth Avenue Ronkonkoma, NY 11779 www.vacuuminst.com Smart Charge II An advanced gas backfill and evacuation system with built-in gross leak test.
Automatic Back-Flushing Filter AutoFilt RF9.
Automatic Back-Flushing Filter AutoFilt RF9. AutoFilt RF9 Clearing the Way. The Challenge: In response to the Tier III standard which will come into effect in 2016, the International Maritime Organization
AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS
AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS Products Include: 60 gpm eductors Style 3060, 3061, 3062 & 3070 95 gpm eductors Style
Fiscal Measurement Natural Gas
White Paper FSG-WP-0012 February 2014 Fiscal Measurement Natural Gas Fiscal Measurement How much? Fiscal Measurement must not be confused with Custody Transfer; in fact, fiscal measurement is a more general
Precision Humidity Measurement for Pharmaceutical Fluid Bed Tablet Coating
Precision Humidity Measurement for Pharmaceutical Fluid Bed Tablet Coating are several reasons why tablet cores are coated, including: Alpharma/Purepac is one of the largest global generic pharmaceutical
TECHNIQUES FOR NATURAL GAS SAMPLING A DISCUSSION OF FIELD METHODS FOR OBTAINING SPOT SAMPLES. Randall Messman SW Regional Sales Manager
TECHNIQUES FOR NATURAL GAS SAMPLING A DISCUSSION OF FIELD METHODS FOR OBTAINING SPOT SAMPLES Randall Messman SW Regional Sales Manager PGI International 16101 Vallen Drive Houston, TX 77041 Purpose Natural