HOW TO SIZE A PRESSURE REGULATOR
|
|
|
- Hilda Miller
- 9 years ago
- Views:
Transcription
1 CHOOSING THE CORRECT REGULATOR HOW TO SIZE A PRESSURE REGULATOR In order to choose the correct regulator the following information is needed: - Function: Pressure reducing or backpressure control? - Pressure: What are the maximum and minimum inlet and outlet pressure ranges? - Fluid: Is it a gas or a liquid? - Temperature: What is the operating temperature? - Flow: What are the flow requirements? Valve sizing does not refer to the size of the end connections. It means determining how much flow can pass through the pressure regulator. There is quite a difference in sizing regulators for gas or for liquids, because gases are compressible and liquids are not. SIZING FOR LIQUIDS The flow equations used for sizing for liquids have their roots in: - Bernouilli s energy equation - the continuity equation The continuity equation states that the volume flow (Qv) flowing through a pipe cross-section (A) in a unit of time is always constant. Qv = A x V(velocity). This implies that velocity must increase as the cross-section becomes smaller to maintain the same volume flow. The conclusion is that because liquids are incompressible, their flow rate depends only on the pressure drop. As long as the difference between P1 and P2 is the same, the flow is the same, no matter if the system pressure is high or low. Important: It is important to realize that whatever goes through the regulator seat will go though the outletport of the regulator. However, we want controlled pressure, not pressure drop or noise. To keep this pressure drop and noise within acceptable limits a rule of thumb says that velocities should not exceed: 1m/sec : suction side of reciprocating pumps 2m/sec : suction side of centrifugal pumps 1m/sec : return line of pumps 4,5 m/sec: delivery side of pumps Another rule of thumb says not to exceed a velocity of 4,5 m/sec for pressure above 7 bar. Calculate a velocity in a pipe: Formula: V = 278 Q A V = m/sec Q = m 3 / hr A = area in mm 2 As A = ¼ Πd 2, you can also calculate the diameter. Effects of specific gravity (s.g.) The significance of s.g. on liquid flow is diminished because it is a square root function. Only if the s.g. is very high or very low will the flow change by more than 10 % from that of water. Effects of temperature. As the effects are too small these can be ignored.
2 SIZING FOR GASES General information Because gases are compressible sizing for gases is not as straightforward as sizing for liquids. The density of gases changes with pressure. Orifices There are two orifices (holes) in a regulator which need to be looked at: 1 the seat orifice 2 the outlet orifice The seat orifice. This is a restriction inside the regulator body. When a flowing fluid ( gas or liquid) flows through a restriction into a lower pressure environment the velocity MUST increase as this fluid flows through this restriction. (Conservation of mass). At the same time the pressure decreases. If the pressure decreases to a point where the P1 = x P2 or more, we have a choked flow situation, where the velocity through the restriction becomes sonic. This situation is also called critical flow. A choked flow condition is a limiting one, because, even if the downstream pressure increases further ( to zero for example), the flow cannot increase. Gas cannot achieve a velocity greater than sonic. Thus, if the pressure drop is big enough the seatflow depends on the inletpressure and not on the outletpressure. See maximum flow. If we have a non-critical flow, when P2 is more than 0,5 x P1, the flow through the seat is restricted by the high outletpressure. This is the situation where we need to apply the correction factor (Y). One can also use the seatsizing formula to calculate the maximum flow through any particular regulator. Example: The maximum airflow through model RS6, with 10 bar inlet pressure is: 0.33 x 11 x 67 = 243 Nm³/ hour of air. (Does not apply to regulators with filters.) This is the flow which a safety valve should be able to pass. The first thing to do is to calculate the seat orifice area A1. The outlet orifice A rule of thumb says that energy cannot be destroyed. It means that whatever quantity one can feed through a seat will come out of the regulator. However.. the question is in what form will this energy come out of the regulator. As velocity, noise, temperature or droop? All we want is: controlled outlet pressure with as little as possible droop. To achieve that we have to look at orifice number 2.. the outlet. In order to achieve this controlled outlet pressure we have to keep the velocity of the fluid on the P2 side at an acceptable level. For gases in general this is: m/sec. and for liquids 4,5-5 m/sec. This of course is a rule of thumb. Now we calculate the required outlet orifice area while assuming a certain velocity. The formula tells us that a given flow at a certain pressure requires a certain area in order to flow through that area at the assumed velocity.
3 ACTUAL SIZING FOR GASES The following information is required to select the most suitable regulator: - the maximum and minimum inlet and outlet pressure - the fluid - the flow requirement - the temperature - materials of construction The next step is to calculate the: - seat orifice area (A1) : the flow area between a valve stem and the seat with the valve fully opened. - outlet port area (A2) : the area of the internal passage in the regulator outlet connection. Please note that the following formulae are used to determine the flow of air through a regulator. Correction factors for other gases are shown on the next page. Calculating the seat orifice area (A1) Use the formula: 0.33 x A1 x P1 = Q1 (does not apply to regulators with filters). A1 = seat orfice area in mm² P1 = inletpressure in bar (a) Q1 = max. flow of air in Nm³/hour through the seat orifice area. Normally the customer gives you the flow (Q1) and the gas. If the gas is not air convert the gasflow to airflow. The customer should also give you the inletpressure (P1) and the outletpressure (P2). Knowing these 3 parameters you can calculate the seat orifice area (A1). Remember! If you know 3 out of 4 parameters you can always calculate the unknown fourth. Non-choked flow A non-choked flowsituation ( or non-critical) occurs when the outlet pressure (P2) is more than half the inlet pressure (P1). P2 > 0,5 x P1 Simply said you need a bigger seat orifice area to pass a flow, because of the small pressure differential. To make sure that the sizing is correct multiply seat area flow Q1 by correction factor Y. Correction factor Y P2 (in bar abs.) P1 (in bar abs.) Multiplyer Y 0,975 0,1 0,95 0,31 Formula: 0,33 x A1 x P1 x Y =Q1 0,925 0,52 0,9 0,6 0,85 0,71 0,8 0,8 0,75 0,86 0,7 0,91 0,65 0,95 0,6 0,98 0,55 0,99 0,5 1
4 Maximum flow To determine the maximum flow through a regulator use either: - the seat orifice area formula, or - the nomograph. As long as there is a choked (critical) flow, (P1 = 2 x P2 at least), the flow which you will find on the nomograph is the maximum flow with the valve wide open. The nomograph also allows you to find the maximum flows for smaller differential pressures. The flows which you find for any given pressure differential can be used for sizing a relief valve. Note! The nomograph does not say anything about accuracy, it just gives you maximum flows. Calculating the outlet port area (A2) Use the formula: 0,10 x A2 x P2 = Q2 (assuming a velocity in the downstream piping of 30 M/sec.) 0,18 x A2 x P2 = Q2 (assuming a velocity in the downstream piping of 50 M/sec.) 0,30 x A2 x P2 = Q2 (assuming a velocity in the downstream piping of 75 M/sec.) A2 = outlet port area in mm² P2 = outlet pressure in bar abs Q2 = flow of air in Nm³/hour through the outlet port area at the selected velocity. Remember that Q2 is the flow which the customer has given you. Correction for other gases Multiply the maximum airflow through the seat area (Q1) by the following factors to obtain the specific gas flow. Hydrogen : 3,81 Nitrogen : 1,02 Oxygen : 0,95 Helium : 2,695 Argon : 0,85 Neon : 1,28 Carbon dioxide : 0,8 Carbon monoxide : 1,0 Ammonia : 1,27 Methane : 1,8 Acetylene : 1,05 Chlorine : 0,64 Ethane : 1,0 Ethylene : 1,03 Hydrogen sulphide : 0,93 Nitrous oxide : 0,83 Propane : 0,82 Sulphur dioxide : 0,68 Lpg : 0,8 Natural gas : 1,30
5 USEFULL DATA 1 mbar = 1 hpa = 10 mm w.c. 1 kpa = 10 mbar 1 bar = 100 kpa 1 MPa = 10 bar 1 mm Hg = 1,333 mbar 1 Hg = 33,858 mbar 1 UK gallon = 4,55 L 1 US gallon = 3,785 L 1 m 3 = 35,315 ft 3 C = 5/9 ( F 32) F = 9/5 ( C + 32) K = C + 273,15 Cv value Cv value is the flowcoefficient indicating the flow of water in U.S.gallons/min at a ΔP of 1 psi and a watertemperature of 60 F. Kv value Kv value is the flowcoefficient indicating the flow of water in m 3 /hr at a ΔP of 1 bar and a watertemperature of 5-30 C. Kv = 0,86 x Cv Kvs value Kvs value is the Kv value with the valve fully open. Gives the maximum possible flow through a regulator. RULE OF THUMB Size a regulator based on the largest possible flow and the smallest ΔP. Should you come close to the limit of a regulator take the next larger one. Note Our formulas apply to ordinary gases and liquids. They do not apply to gases or vapours near or at the point of liquefaction. Also they do not apply to boiling or very viscous liquids. Safe Product Selection When selecting a product, the total system design must be considered to ensure safe, troublefree performance. Function, material compatibility, adequate ratings, proper installation, operation, and maintenance are the responsibilities of the system designer and user. RHPS, Swagelok TM Swagelok Company 2010 Swagelok Company Printed in U.S.A., OM June 2010, R0 MS E
Valve Sizing. Te chnic al Bulletin. Flow Calculation Principles. Scope. Sizing Valves. Safe Product Selection. www.swagelok.com
www.swagelok.com Valve Sizing Te chnic al Bulletin Scope Valve size often is described by the nominal size of the end connections, but a more important measure is the flow that the valve can provide. And
BASIC UNDERSTANDING OF FLOW CALCULATIONS AND ESTIMATES MAKES SIZING VALVES SIMPLER
BASIC UNDERSTANDING OF FLOW CALCULATIONS AND ESTIMATES MAKES SIZING VALVES SIMPLER Valve size often is described by the nominal size of the end connections but a more important measure is the flow that
Certain specific properties of compressed gases make them highly useful in various research activities.
GAS CYLINDER SAFETY Introduction Certain specific properties of compressed gases make them highly useful in various research activities. These gases, however, can be dangerous if not handled in an appropriate
Regulator Options and Accessories
Regulator Options and Accessories Regulator accessories are available separately or mounted on Swagelok regulators. Some accessories limit regulator pressure or temperature ratings. Additional materials,
Sizing Pressure Regulators & Control Valves
Sizing Pressure Regulators & Control Valves ( ( Sizing the Pressure Regulators Sizing of regulators is usually made on the basis of Cg valve and KG sizing coefficients. Flow rates at fully open position
T U R B I N E G A S M E T E R
TURBINE GAS METER TURBINE GAS METER CGT 1 2 3 4 5 6 7 Design and function page 2 General technical data page 3 Measurement outputs page 4 Dimensions and weights page 5 Performance page 7 Pressure loss
CO 2 41.2 MPa (abs) 20 C
comp_02 A CO 2 cartridge is used to propel a small rocket cart. Compressed CO 2, stored at a pressure of 41.2 MPa (abs) and a temperature of 20 C, is expanded through a smoothly contoured converging nozzle
COMBUSTION. In order to operate a heat engine we need a hot source together with a cold sink
COMBUSTION In order to operate a heat engine we need a hot source together with a cold sink Occasionally these occur together in nature eg:- geothermal sites or solar powered engines, but usually the heat
Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing 408-409
Engineering Data Table of Contents Page No. I II Formulas, Conversions & Guidelines Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Sizing 408-409 Steam
CHEMISTRY GAS LAW S WORKSHEET
Boyle s Law Charles Law Guy-Lassac's Law Combined Gas Law For a given mass of gas at constant temperature, the volume of a gas varies inversely with pressure PV = k The volume of a fixed mass of gas is
7-5.5. Translate chemical symbols and the chemical formulas of common substances to show the component parts of the substances including:
7-5.5 Translate chemical symbols and the chemical formulas of common substances to show the component parts of the substances including: NaCl [salt], H 2 O [water], C 6 H 12 O 6 [simple sugar], O 2 [oxygen
1301 Series High-Pressure Regulators
1301 Series High-Pressure Regulators Bulletin 71.1:1301 December 2013 P10 Figure 1. Type 1301F Regulator Features Durable Stainless Steel Diaphragm For high-outlet pressure applications. Spare Valve Disk
Pressure and Temperature Controls
Pressure and Controls Pressure Reducing Armstrong pressure reducing valves (PRVs) and temperature regulators help you manage steam, air and liquid systems safely and efficiently. And assure uninterrupted
Theory, Application, and Sizing of Air Valves
Theory, Application, and Sizing of Air Valves VAL-MATIC VALVE AND MANUFACTURING CORP. 905 RIVERSIDE DRIVE, ELMHURST, IL 60126 TEL. (630) 941-7600 FAX. (630) 941-8042 www.valmatic.com 1 THEORY, APPLICATION,
Air Eliminators and Combination Air Eliminators Strainers
Description Air Eliminators and Combination Air Eliminator Strainers are designed to provide separation, elimination and prevention of air in piping systems for a variety of installations and conditions.
THE HUMIDITY/MOISTURE HANDBOOK
THE HUMIDITY/MOISTURE HANDBOOK Table of Contents Introduction... 3 Relative Humidity... 3 Partial Pressure... 4 Saturation Pressure (Ps)... 5 Other Absolute Moisture Scales... 8 % Moisture by Volume (%M
Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur
Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur Lecture No. # 22 Refrigeration System Components: Compressor (Continued)
Temperature. Number of moles. Constant Terms. Pressure. Answers Additional Questions 12.1
Answers Additional Questions 12.1 1. A gas collected over water has a total pressure equal to the pressure of the dry gas plus the pressure of the water vapor. If the partial pressure of water at 25.0
1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.
Sample Questions REVISED FIRST CLASS PARTS A1, A2, AND A3 (NOTE: these questions are intended as representations of the style of questions that may appear on examinations. They are not intended as study
PRESSURE REGULATOR SERIES 2100-4100 - 5100 R 4100 R 2100 R 5100 VIRTUAL CATALOGUE FAIL TO OPEN REGULATOR BALANCED VALVE HIGH FLOW COEFFICIENT
VIRTUAL CATALOGUE FAIL TO OPEN REGULATOR BALANCED VALVE HIGH FLOW COEFFICIENT PRESSURE REGULATOR WIDE PRESSURE-REGULATION RANGE CAN BE SUPPLIED WITH MINIMUM / MAXIMUM PRESSURE SLAM-SHUT VALVE R 4100 POSSIBILITY
FLUID FLOW Introduction General Description
FLUID FLOW Introduction Fluid flow is an important part of many processes, including transporting materials from one point to another, mixing of materials, and chemical reactions. In this experiment, you
Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.
ASGMT / Averaging Pitot Tube Flow Measurement Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc. Averaging Pitot Tube Meters Introduction
Fluid & Gas Properties
Fluid & Gas Properties FLUID DENSITY Density is the ratio of mass to volume. In English, units density is expressed in pounds mass/cubic foot (lbm/ft 3 ). The symbol for density is ρ. Density is usually
Facility Operations Physical Safety Guidance Document
Facility Operations Physical Safety Guidance Document Title: Guide on Pipe Identification Standards (ASME A13.1-1996) Original Date: December 18, 2000 Section: 4.0 Facility Operations Revised Date: Number:
Chapter 10. Flow Rate. Flow Rate. Flow Measurements. The velocity of the flow is described at any
Chapter 10 Flow Measurements Material from Theory and Design for Mechanical Measurements; Figliola, Third Edition Flow Rate Flow rate can be expressed in terms of volume flow rate (volume/time) or mass
CONTROL VALVE PRESSURE DROP AND SIZING
CONTENT Chapter Description Page I Purpose of Control Valve II Type and Main Components of Control Valve 3 III Power 5 IV. Pressure Drop Across Control Valve 7 V. Symbols and Units 10 VI. Unit Conversion
Chemical Calculations: Formula Masses, Moles, and Chemical Equations
Chemical Calculations: Formula Masses, Moles, and Chemical Equations Atomic Mass & Formula Mass Recall from Chapter Three that the average mass of an atom of a given element can be found on the periodic
Chapter 19 Purging Air from Piping and Vessels in Hydrocarbon Service
BP Lower 48 Onshore Operations Safety Manual Page 4.19 1 Chapter 19 Purging Air from Piping and Vessels in Hydrocarbon Service I. General Requirements A. After motor vehicle accidents and underground excavation
Unit 3 Notepack Chapter 7 Chemical Quantities Qualifier for Test
Unit 3 Notepack Chapter 7 Chemical Quantities Qualifier for Test NAME Section 7.1 The Mole: A Measurement of Matter A. What is a mole? 1. Chemistry is a quantitative science. What does this term mean?
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
Name Date Class STOICHIOMETRY. SECTION 12.1 THE ARITHMETIC OF EQUATIONS (pages 353 358)
Name Date Class 1 STOICHIOMETRY SECTION 1.1 THE ARITHMETIC OF EQUATIONS (pages 353 358) This section explains how to calculate the amount of reactants required or product formed in a nonchemical process.
C. starting positive displacement pumps with the discharge valve closed.
KNOWLEDGE: K1.04 [3.4/3.6] P78 The possibility of water hammer in a liquid system is minimized by... A. maintaining temperature above the saturation temperature. B. starting centrifugal pumps with the
Water hammering in fire fighting installation
Water hammering in fire fighting installation Forward One of major problems raised in the fire fighting network installed at Pioneer company for pharmaceutical industry /Sulaymania was the high water hammering
The Gas Laws. Our Atmosphere. Pressure = Units of Pressure. Barometer. Chapter 10
Our Atmosphere The Gas Laws 99% N 2 and O 2 78% N 2 80 70 Nitrogen Chapter 10 21% O 2 1% CO 2 and the Noble Gases 60 50 40 Oxygen 30 20 10 0 Gas Carbon dioxide and Noble Gases Pressure Pressure = Force
= 800 kg/m 3 (note that old units cancel out) 4.184 J 1000 g = 4184 J/kg o C
Units and Dimensions Basic properties such as length, mass, time and temperature that can be measured are called dimensions. Any quantity that can be measured has a value and a unit associated with it.
1805 Series Relief Valves
October 2011 1805 Series Relief Valves P1026 1805G Type 1805-2 Type 1805-4 Figure 1. Typical 1805 Relief Valves Introduction The 1805 Series relief valves are designed for use in farm tap applications
Select the Right Relief Valve - Part 1 Saeid Rahimi
Select the Right Relief Valve - Part 1 Saeid Rahimi 8-Apr-01 Introduction Selecting a proper type of relief valve is an essential part of an overpressure protection system design. The selection process
At the temperature of liquid hydrogen, however, 99.8% of the hydrogen molecules will be in the para form.
1 ydrogen What is hydrogen? ydrogen is one of the elements, as are helium, carbon, nitrogen, oxygen, neon, sodium, aluminum, sulfur, chlorine, potassium, iron, nickel, copper zinc, silver, platinum, gold,
Fiscal Measurement Natural Gas
White Paper FSG-WP-0012 February 2014 Fiscal Measurement Natural Gas Fiscal Measurement How much? Fiscal Measurement must not be confused with Custody Transfer; in fact, fiscal measurement is a more general
SIZING AND CAPACITIES OF GAS PIPING
APPENDIX A (IFGS) SIZING AND CAPACITIES OF GAS PIPING (This appendix is informative and is not part of the code.) A.1 General. To determine the size of piping used in a gas piping system, the following
Gas Custody Transfer Calibration
Gas Custody Transfer Calibration Using multi variable temperature / pressure calibrators for flowmeter calibration 2013 Introduction Gas custody transfer flow computers require special calibration to perform
F321 MOLES. Example If 1 atom has a mass of 1.241 x 10-23 g 1 mole of atoms will have a mass of 1.241 x 10-23 g x 6.02 x 10 23 = 7.
Moles 1 MOLES The mole the standard unit of amount of a substance (mol) the number of particles in a mole is known as Avogadro s constant (N A ) Avogadro s constant has a value of 6.02 x 10 23 mol -1.
All Safe, Inc. Sherwood Master Distributor Toll Free: 866-958-3473 Fax: 651-408-7163 Email: [email protected] www.allsafenet
Toll Free: Fax: 651-408-7163 Email: [email protected] www.allsafenet SHERWOOD GLOBAL VALVE FEATURES Durable forged brass body, precisely machined internal components and design elements meet the most stringent
Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange
Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Description VF 2 VF 3 VF 2 and VF 3 valves provide a quality, cost effective solution for most water and chilled applications. The
Stoichiometry. 1. The total number of moles represented by 20 grams of calcium carbonate is (1) 1; (2) 2; (3) 0.1; (4) 0.2.
Stoichiometry 1 The total number of moles represented by 20 grams of calcium carbonate is (1) 1; (2) 2; (3) 01; (4) 02 2 A 44 gram sample of a hydrate was heated until the water of hydration was driven
Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson
Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology HWEA 2011 Conference Craig S. Johnson Presentation Overview Introduction Aeration Air & Digester gas challenges Gas flow metering
FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters
FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters M-4270/0707, pg. 2 of 29 READ THIS MANUAL COMPLETELY BEFORE ATTEMPTING TO CONNECT OR OPERATE YOUR FLOW SENSOR. FAILURE TO DO SO MAY
pressure inside the valve just before the final release of air. in pipeline systems resulting from 2p 1 p a m C D A o
BY SRINIVASA LINGIREDDY, DON J. WOOD, AND NAFTALI ZLOZOWER It is a common practice to locate air valves at high elevations along water transmission mains. Improper sizing of an air valve could lead to
The Fundamentals of Gas Flow Calibration
The Fundamentals of Gas Flow Calibration Application Note Introduction Understanding the fundamentals of gas flow calibration is essential for evaluating calibration systems, estimating the magnitude of
AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS
AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS Products Include: 60 gpm eductors Style 3060, 3061, 3062 & 3070 95 gpm eductors Style
Element D Services Plumbing
Medical Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses medical vacuum, waste anesthetic gas disposal, compressed air, oxygen, nitrous oxide, nitrogen and carbon dioxide systems.
VAL-MATIC VALVE AND MANUFACTURING CORP. 905 RIVERSIDE DRIVE, ELMHURST, IL 60126 TEL. (630) 941-7600 FAX.
Cavitation in Valves VAL-MATIC VALVE AND MANUFACTURING CORP. 905 RIVERSIDE DRIVE, ELMHURST, IL 60126 TEL. (630) 941-7600 FAX. (630) 941-8042 www.valmatic.com CAVITATION IN VALVES INTRODUCTION Cavitation
Engineering Guide and Valve Selection Information
Engineering Guide and Valve Selection Information GC Valves Delivers Quality from the Inside Out We use only stainless steel hardware on our diaphragms. This includes the pilot orifice a wear point for
Dynamic Process Modeling. Process Dynamics and Control
Dynamic Process Modeling Process Dynamics and Control 1 Description of process dynamics Classes of models What do we need for control? Modeling for control Mechanical Systems Modeling Electrical circuits
1800C and 1800C-HC Series Service Regulators. Technical Bulletin
and -H Series Service Regulators Technical Bulletin and -H Series Service Regulators 0 Elster American Meter The Series pressure regulators are designed to control natural gas, air, nitrogen, carbon dioxide,
Appendix I: Cryogenic Reference Tables
Appendix I: Cryogenic Reerence Tables Appendices 217 Appendix I: Cryogenic Reerence Tables Cryogenic heat low calculations The heat low Q conducted across small temperature dierences can be calculated
Stoichiometry Exploring a Student-Friendly Method of Problem Solving
Stoichiometry Exploring a Student-Friendly Method of Problem Solving Stoichiometry comes in two forms: composition and reaction. If the relationship in question is between the quantities of each element
PRESSURE REDUCER AND RELIEF VALVES WITH METALLIC BELLOW FOR WATER STEAM
PRESSURE REDUCER AND RELIEF VALVES WITH METALLIC BELLOW FOR WATER STEAM PRESSURE REDUCER AND RELIEF VALVES These devices are used to reduce and control a gaseous flow pressure (air, steam, gas ). The PRESSURE
The Versatile Differential Pressure Transmitter. By David Gunn Honeywell Process Solutions
The Versatile Differential Pressure Transmitter By David Gunn Honeywell Process Solutions The Versatile Differential Pressure Transmitter 2 Table of Contents Abstract... 3 Pressure Fundamentals... 3 Applications...
NITROUS TRANSFER PUMP INSTRUCTIONS
NITROUS TRANSFER PUMP INSTRUCTIONS SAFETY TIPS Never directly inhale nitrous oxide. When inhaled in large quantities, nitrous oxide can cause respiratory ailments or in extreme cases, death by suffocation.
PIEZOMETER AIRFLOW MEASURING RING
PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer
Mechanical Seal Piping Plans
Mechanical Seal Piping Plans Single Seals plans 01, 02, 03, 11, 13, 14, 21, 23, 31, 32, 41 Dual Seals plans 52, 53A, 53B, 53C, 54, 55 Quench Seals plans 62, 65A, 65B, 66A, 66B Gas Seals plans 72, 74, 75,
AS1 MOLES. oxygen molecules have the formula O 2 the relative mass will be 2 x 16 = 32 so the molar mass will be 32g mol -1
Moles 1 MOLES The mole the standard unit of amount of a substance the number of particles in a mole is known as Avogadro s constant (L) Avogadro s constant has a value of 6.023 x 10 23 mol -1. Example
UNDERSTANDING REFRIGERANT TABLES
Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois 60016 UNDERSTANDING REFRIGERANT TABLES INTRODUCTION A Mollier diagram is a graphical representation of the properties of a refrigerant,
Chapter 17. For the most part, we have limited our consideration so COMPRESSIBLE FLOW. Objectives
Chapter 17 COMPRESSIBLE FLOW For the most part, we have limited our consideration so far to flows for which density variations and thus compressibility effects are negligible. In this chapter we lift this
Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9
Pumping Systems, Intensifiers, Gas Boosters and High Pressure Generators High Pressure Equipment Company produces a number of components and systems for general industrial, elevated pressure applications.
Advanced Differential Pressure Flowmeter Technology V-CONE FLOW METER TECHNICAL BRIEF
Advanced Differential Pressure Flowmeter Technology V-CONE FLOW METER TECHNICAL BRIEF Table of Contents Section 1 - General Introduction 1.1 1 Principles Of Operation 1.2 1 Reshaping The Velocity Profile
7. 1.00 atm = 760 torr = 760 mm Hg = 101.325 kpa = 14.70 psi. = 0.446 atm. = 0.993 atm. = 107 kpa 760 torr 1 atm 760 mm Hg = 790.
CHATER 3. The atmosphere is a homogeneous mixture (a solution) of gases.. Solids and liquids have essentially fixed volumes and are not able to be compressed easily. have volumes that depend on their conditions,
Sheet 5:Chapter 5 5 1C Name four physical quantities that are conserved and two quantities that are not conserved during a process.
Thermo 1 (MEP 261) Thermodynamics An Engineering Approach Yunus A. Cengel & Michael A. Boles 7 th Edition, McGraw-Hill Companies, ISBN-978-0-07-352932-5, 2008 Sheet 5:Chapter 5 5 1C Name four physical
Physical and Chemical Properties of Matter
Physical and Chemical Properties of Matter What is matter? Anything that has mass and takes up space Chemical or Physical Property? Physical properties of matter: characteristics that can be observed or
RITTER Multiple Sonic Nozzle Calibration System
RITTER Multiple Sonic Nozzle Calibration System »Wouldn t it be great to eliminate doubtful measurement results by using proven measurement technology? Providing the most precise results ensures and increases
PULSATION REDUCTION BY ACOUSTIC FILTERS FOR METERING APPLICATIONS. Robert J. McKee Ray G. Durke
PULSATION REDUCTION BY ACOUSTIC FILTERS FOR METERING APPLICATIONS Robert J. McKee Ray G. Durke Southwest Research Institute 6220 Culebra Road San Antonio, TX 78238 INTRODUCTION Because of the adverse effects
289 Series Spring-Loaded Relief Valves
October 14 89 Series Spring-Loaded Relief Valves W187_1 W1871 TYPE 89L 1 NPT TYPES 89H AND 89HH W187 NPT TYPE 89H W187_ TYPES 89U AND 89A Figure 1. Types 89H, 89L and 89U Relief Valves Introduction The
Application of the Orifice Meter for Accurate Gas Flow Measurement page 1. Application of the Orifice Meter for Accurate Gas Flow Measurement.
Application of the Orifice Meter for Accurate Gas Flow Measurement page 1 DANIEL MEASUREMENT AND CONTROL WHITE PAPER Application of the Orifice Meter for Accurate Gas Flow Measurement www.daniel.com Summary
UCLA - Compressed Gas Cylinder Storage and Handling
UCLA - Compressed Gas Cylinder Storage and Handling Purpose UCLA is committed to provide safety guidelines concerning the handling and use of portable compressed gas cylinders. Compressed gases represent
Vacuum Control. Vacuum Applications. Vacuum Regulators. Vacuum Breakers (Relief Valves) Vacuum Control Devices. Vacuum Terminology
Vacuum Applications Vacuum regulators and breakers are widely used in process plants. Conventional regulators and relief valves might be suitable for service if applied correctly. This section provides
Tadahiro Yasuda. Introduction. Overview of Criterion D200. Feature Article
F e a t u r e A r t i c l e Feature Article Development of a High Accuracy, Fast Response Mass Flow Module Utilizing Pressure Measurement with a Laminar Flow Element (Resistive Element) Criterion D200
Pump Formulas Imperial and SI Units
Pump Formulas Imperial and Pressure to Head H = head, ft P = pressure, psi H = head, m P = pressure, bar Mass Flow to Volumetric Flow ṁ = mass flow, lbm/h ρ = fluid density, lbm/ft 3 ṁ = mass flow, kg/h
20.2 Chemical Equations
All of the chemical changes you observed in the last Investigation were the result of chemical reactions. A chemical reaction involves a rearrangement of atoms in one or more reactants to form one or more
Compressor Performance
expertise beyond controls Compressor Performance Advisor (CPA) Software Monitoring compressor performance for the purpose of evaluating compressor productivity and optimizing maintenance intervals is an
SIZING AND CAPACITIES OF GAS PIPING (Not Adopted by the State of Oregon)
(IFGS) SIZING AND CAPACITIES OF GAS PIPING (Not Adopted by the State of Oregon) (This appendix is informative and is not part of the code. This appendix is an excerpt from the 2006 International Fuel Gas
Guide to good leak testing
Page 0 Guide to good leak testing The Institute of Refrigeration, working with the Carbon Trust, brings you REAL Zero Refrigerant Emission and Loss Zero. The aim of this project is in the title zero refrigerant
How To Design A Refrigeration System
AIRAH Refrigeration (in HVAC) Back to Basics For the First Time Terms of Reference What this session is NOT about Detailed Refrigeration Design Detailed analysis of various Refrigants properties Comparison
APPENDIX A CONTROL VALVE TESTING PROCEDURES AND EQUATIONS FOR LIQUID FLOWS
APPENDIX A CONTROL VALVE TESTING PROCEDURES AND EQUATIONS FOR LIQUID FLOWS Section A.1. Flow Coefficients Definition The flow coefficient or pressure loss coefficient is used to relate the pressure loss
Material taken from Fluid Power Circuits and Controls, John S. Cundiff, 2001
Pressure Control Chapter 3 Material taken from Fluid Power Circuits and Controls, John S. Cundiff, 2001 Introduction Pressure control is a key element in the design of any circuit. Used correctly, it can
DIN 2403 Identification of pipelines according to the fluid conveyed. Marking of pipes according to fluid transported
DIN 2403 Identification of pipelines according to the fluid conveyed. Marking of pipes according to fluid transported 1 Field of application This standard specifies the colours for the identification of
Chapter 2 Chemical and Physical Properties of Sulphur Dioxide and Sulphur Trioxide
Chapter 2 Chemical and Physical Properties of Sulphur Dioxide and Sulphur Trioxide 2.1 Introduction In order to appreciate the impact of the properties of liquid sulphur dioxide and liquid sulphur trioxide
User s Manual Laminar Flow Elements
501:440-13 User s Manual Laminar Flow Elements 10920 Madison Avenue Cleveland, Ohio 44102 Tel: 216.281.1100 email:[email protected] Web:www.meriam.com 1 TABLE OF CONTENTS Subject Page Introduction... 3
Meriam Instrument LFE Data Sheet
1. AIR FLOW IN SCFM AT STANDARD CONDITIONS OF 29.92 AND 70 F. SCFM = Standard cubic feet per minute. ACFM = Actual cubic feet per minute CFM = Cubic feet per minute. When the flowing gas is air and the
Flashing and Cavitation
As seen in the Summer 2015 issue of MAGAZINE BACK TO BASICS A high-power boiler burner in a co-generation plant Flashing and Cavitation Some of the following questions may seem unrelated, but they all
Anti-Cavitation Trim. Eliminates cavitation damage Reduces noise Preserves valve and surrounding pipe systems. singervalve.com
Anti-Cavitation Trim Eliminates cavitation damage Reduces noise Preserves valve and surrounding pipe systems Say Goodbye to Cavitation Damage! Cavitation, a common problem in pumps and control valves,
Proportional Relief Valves
www.swagelok.com Proportional Relief Valves R Series Liquid or gas service Set pressures from 10 to psig (0.7 to 413 bar) 1/4 and 1/2 in. and 6 to 12 mm end connections 2 Proportional Relief Valves Spring
Module 5: Combustion Technology. Lecture 33: Combustion air calculation
1 P age Module 5: Combustion Technology Lecture 33: Combustion air calculation 2 P age Keywords: Heat of combustion, stoichiometric air, excess air, natural gas combustion Combustion air calculation The
Fluid Power Formula. These Formula Cover All Fluid Power Applications In This Manual
These Formula Cover All Fluid Power Applications In This Manual For Computer Programs To Work Problems By Simply Filling In The Blanks See Your Local Fluid Power Distributor Many Companies Web Site Or
Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)
Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC) VPS 504 S06 (120 VAC) is: CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter R-15 (Canada) UL
Regulator Performance Data
Regulator Performance Data The regulator flow data is provided to assist in determining the proper regulator for the required application. The data is given for reference purpose only. If additional information
OIL-X EVOLUTION Compressed Air Filters ENGINEERING YOUR SUCCESS. TECNI-AR Ltda - Tel: 31 3362-2400 w.tecni-ar.com.br
OIL-X EVOLUTION ENGINEERING YOUR SUCCESS. OIL-X EVOLUTION High Efficiency Compressed Air Filtration OIL-X EVOLUTION is a range of high efficiency compressed air filters consisting of coalescing filter
11.6 Formulas to be used when changing atmosphere in an tank
11.6 Formulas to be used when changing atmosphere in an tank There are some formulas that we can use to calculate the consumption of nitrogen or inert for changing atmosphere in tanks and the time to be
Daniel. Liquid Control Valves Technical Guide. Technical Guide DAN-LIQ-TG-44-rev0813. DAN-LIQ-TG-44-rev0208. February 2008.
DAN-LIQ-TG-44-rev0208 February 2008 Daniel Liquid Control Valves Technical Guide www.daniel.com Daniel Measurement and Control Theory, Principle of Operation and Applications This brochure has been prepared
