Climate solutions. evaporative cooling, adiabatic humidification and programmable controllers. energy saving solutions for data centers. carel.



Similar documents
Integrated solutions for ground source heat pumps

heatersteam precision and reliability for all types of applications

pco sistema... communication Technology & Evolution

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

Temperature & Humidity Control Systems for the Wine Industry

State of the Art Energy Efficient Data Centre Air Conditioning

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

Analysis of data centre cooling energy efficiency

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Integral control solution Air Handling Units

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

Engineering White Paper UTILIZING ECONOMIZERS EFFECTIVELY IN THE DATA CENTER

AERIS DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM

IEC DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM

Direct Fresh Air Free Cooling of Data Centres

AERMEC DATA CENTRE SOLUTIONS THE COMPLETE RANGE OF AERMEC SOLUTIONS FOR DATA CENTRES

Elements of Energy Efficiency in Data Centre Cooling Architecture

Liebert EFC from 100 to 350 kw. The Highly Efficient Indirect Evaporative Freecooling Unit

White Paper: Free Cooling and the Efficiency of your Data Centre

Modular Data Center Cooling. Ultra High Efficiency. Oasis Optimum DCIE

Energy Efficient Server Room and Data Centre Cooling. Computer Room Evaporative Cooler. EcoCooling

How To Design A Building In New Delhi

Legacy Data Centres Upgrading the cooling capabilities What are the options?

Excool Indirect Adiabatic and Evaporative Data Centre Cooling. World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

Free Cooling for Data Centers

ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE

- White Paper - Data Centre Cooling. Best Practice

News in Data Center Cooling

PERCENT OUTDOOR AIR (%OA) CALCULATION AND ITS USE

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

New generation......continuity, innovation, design

STULZ Water-Side Economizer Solutions

Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages

NSIDC Data Center: Energy Reduction Strategies

The Different Types of Air Conditioning Equipment for IT Environments

Green Data Center: Energy Reduction Strategies

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

3/29/2012 INTRODUCTION HVAC BASICS

I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 4, Lancaster University, 2 nd July 2014

CRAC Precision climate control units for data centres

Data Centre Cooling Air Performance Metrics

White Paper #10. Energy Efficiency in Computer Data Centers

Data Centre Cooling Technologies. Jon Pettitt, EMEA DataCenter Business Development Manager

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

STULZ View On DataCenter Cooling

System solution for data centres

Economizer Fundamentals: Smart Approaches to Energy-Efficient Free-Cooling for Data Centers

Indirect Evaporative Cooling (IDEC) Unit for Data Centers

National Grid Your Partner in Energy Solutions

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Award-Winning Innovation in Data Center Cooling Design

Advanced connectivity solutions

OASIS PRODUCT GUIDE. Data Centre Cooling INDIRECT EVAPORATIVE COOLER. Data Centres. Telecoms. EPX technology. Class leading performance

Knowledge for optimal efficiency

toepassingen en bijhorende controle aircotech verdeelt Carel

Improving Data Center Energy Efficiency Through Environmental Optimization

Screw Compressors ESM Fixed Speed & VS Variable Speed

Element D Services Heating, Ventilating, and Air Conditioning

Data Center Heat Rejection

Reduce data center PUE using Munters innovative cooling solutions

Managing Data Centre Heat Issues

European Code of Conduct for Data Centre. Presentation of the Awards 2014

Energy Saving Fact Sheet Air Conditioning

Analysis of HVAC Control Strategies

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

Technical Systems. Helen Bedford

Energy Efficiency in New and Existing Data Centers-Where the Opportunities May Lie

Datacenter Efficiency Program

Eurovent Certification for Air Handling Units : Five Energy Efficiency classes to make the right choice

We have been working in an ideal climate for thirty years.

Data Centers WHAT S ONTHEHORIZON FOR NR HVAC IN TITLE ? SLIDE 1

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

60-150kW. For more information on Airedale visit SmartCool kW. > SmartCool.

HVAC Systems: Overview

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Intelligent control system with integrated electronic expansion valves in an air-conditioning system operating at a Telecom telephone exchange

Controlling Wrap-Around Heat Pipes for Systems with Strict Space Humidity Requirements. By Michael O. Davis, PE, November 2015

Bring the fresh in. Dedicated Outside Air Systems

University of St Andrews. Energy Efficient Data Centre Cooling

SURVEY RESULTS: DATA CENTER ECONOMIZER USE

Defining Quality. Building Comfort. Precision. Air Conditioning

Rittal White Paper 507: Understanding Data Center Cooling Energy Usage & Reduction Methods By: Daniel Kennedy

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

Optimization of Water - Cooled Chiller Cooling Tower Combinations

AIR-SITE GROUP. White Paper. Green Equipment Room Practices

Fan Coil Units. Fan coil units with brushless DC motor with inverter. your comfort. our world. » Up to 70% energy saving with BLDC motor technology

Economizer Modes of Data Center Cooling Systems

Data Center Energy Profiler Questions Checklist

How High Temperature Data Centers and Intel Technologies Decrease Operating Costs

GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY. Public Sector ICT Special Working Group

White Paper. Data Center Containment Cooling Strategies. Abstract WHITE PAPER EC9001. Geist Updated August 2010

Sustainable Preservation Practices for Managing Storage Environments Webinar: April 3, 2013

I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 8, Loughborough University, 29 th June 2015

Five Strategies for Cutting Data Center Energy Costs Through Enhanced Cooling Efficiency

RVH/BCH Data Centres Proposals for Surge Protection and Ventilation

Excool Data Centre Cooling Product Comparison Report

Energy Efficiency. Energy Efficient Home Cooling:

Capgemini UK Infrastructure Outsourcing

Transcription:

Climate solutions evaporative cooling, adiabatic humidification and programmable controllers energy saving solutions for data centers carel.com

Data center air-conditioning Data center air-conditioning is essential for the correct operation of Information Technology equipment: processing and storage devices produce considerable heat that needs to be removed in order to maintain optimum operating conditions. Energy saving through evaporative cooling and adiabatic humidification: integration and versatility Worldwide data center power consumption is estimated to be 0 GW, accounting for around.5% of the earth s total electricity usage: as a result of this astonishing level of energy consumption, energy saving solutions are increasingly adopted. Currently the most widely implemented technological solution involves the use of Computer Room Air Conditioners (CRAC) or Close Control Units (CCU), which cool and where necessary humidify the air in the data center. Continuous technological development in the sector and a constant focus on energy saving are reflected in the evolution of the air-conditioning solutions adopted: from controlling air distribution to installing air-conditioners near the heat sources, as well as using high efficiency equipment. Moreover, air handling units can be used to deliver outside air in free cooling mode, and where possible lowering temperatures even further using adiabatic humidifiers (evaporative cooling). Energy saving global energy saving: 68 kw for every 00 l/h of evaporated water, with very low energy consumption and pressure drop (0 Pa). Mission critical Reliable solutions for applications where continuous service and redundancy are essential. Flexibility The energy saving proposals can be used in all applications, including retrofits for improving the PUI of existing data centers.

Evaporative cooling and adiabatic humidification The data center air-conditioning solution with the highest energy efficiency and lowest environmental impact The graph illustrates the climatic conditions in which the evaporative cooling, in case combined with a heat recovery unit, gives the opportunity to reach the temperature and humidity conditions as recommended by ASHRAE and reduces significantly the mechanical cooling energy consumption. The green area (FC ) represents the conditions in which it is possible to use the free cooling, the adjacent area (FC +MIX) describes the conditions in which it is necessary to mix the external air with the return air in order to keep the temperature under control. The area below (FC+MIX+HUMIDIFICATION) needs an additional adiabatic humidification to reach the minimum humidity set by ASHRAE. The blue area (DEC) identifies the initial external air conditions, suitable to reach the temperature set point with direct evaporative cooling DEC only! The yellow area (IEC) represents indirect evaporative cooling IEC using a heat exchanger between the external air and the recirculated internal air; the area (IEC+MECHANICAL COOLING) needs a further mechanical cooling contribution. When the introduction of external air in the data center is not allowed, the IEC contribution will cover the previous DEC scenario. 0 0 0 The outside air condition where mechanical cooling only is required is represented by the red area. Evaporative coolers, such as water spray atomizers, provide highly efficient cooling solutions with the added benefit of humidity control whilst ensuring substantial reduction in energy consumption and costs without any impact on maintenance costs. Optimum control of the airconditioning systems is equally crucial in maximising the energy saving available through 0 C 0 0.775 40 5 C 50 0 C 0.800 0.800 00 60 5 C 70 FC + MIX 0.85 5 C 80 0 C IEC -0-5 0 5 0 5 0 5 0 5 40 45 t db (C) 50 = 00 % 90 t wb = 5 C = 90 % = 80 % = 70 % FC FC + MIX+HUMIDIFICATION 00 = 60 % evaporative cooling and eliminating inefficiencies. = 50 % = 40 % 0.850 0.850 0 C 0 0 0 0 40 h (kj/kg a ) 0 C = 0 % = 0 % = 0 % MECHANICAL COOLING IEC + MECHANICAL COOLING 5 C 0.875 DEC 0.900 0.900 v = = 0.95 0.95 (m (m /kg a ) /kga ) t wb = 5 C 0.950 0 C wb = 5 C Evaporative cooling - the essential book on this cooling technique: an environmentally-friendly way to reduce the power consumption of cooling systems 0 C 0 x (gv /kg a ) 5 0 5 0 5 0 0 0 00 90 80 70 60 50 No dust The water spray humidifiers used for evaporative cooling do not introduce dust into the data center. Connectivity All the programmable controllers feature numerous plug in options for communicating with the most commonly-used BMS. Temperature & humidity control One rational and efficient solution can be used to cool the air through evaporative cooling while controlling humidity.

LABEL WARNING!! Direct free cooling + DEC and adiabatic humidification The solution that optimises the use of outside air, lowering temperatures in summer through direct evaporative cooling (DEC) and controlling humidity in winter, using the same unit Maximum free cooling and DEC efficiency Extension of the period in which free cooling can be used Precise humidity control The system comprises an AHU that introduces outside air in summer for free cooling, plus DEC when the outside conditions allow. The air is humidified and cooled providing approx. 680W/L cooling with a power consumption from just 4W/L. This process is the most efficient method of cooling since it does not involve intermediate heat exchange stages. The air is delivered into the cold aisles and distributed through grills or diffusers. The return fan then draws in air from the hot aisles. A mixing damper controls the minimum supply temperature by modulating recirculation. In winter, the system ensures precise supply humidity control, with a power consumption of only 4W per litre in comparison to 750W per litre for steam humidifiers. pco: management of the AHU components and supply temperature and humidity control humifog: guarantees precision and maximum efficiency in DEC and humidification (supply humidification requires more precise control) VFD inverter to modulate the air volume, minimising total energy consumption

LABEL WARNING!! Indirect air-side free cooling + IEC The solution that maximises free cooling, implementing indirect evaporative cooling without introducing outside air into the data center due to problems such as pollutants, or when humidity levels mean DEC is not feasible The system comprises an AHU that recirculates the air, cooling it via a heat recovery unit that exchanges heat with the outside air. This secondary air stream flows through the heat recovery unit without entering the data center. The evaporative cooler () reduces the secondary air temperature, while at the same time increasing its humidity up to 95%, guaranteeing maximum cooling of the recirculated air. A cooling coil can deliver supplementary cooling capacity if needed, as well as guaranteeing redundancy. In winter, a second water spray humidifier () ensures precise supply humidity control, with a power consumption of just 4 W per litre of atomised water. The air is delivered into the cold aisles and distributed through grills or diffusers. The return fan then draws in air from the hot aisles. 4 pco: management of the AHU components and supply temperature and humidity control optimist: guarantees humidity control and a considerable energy savings through IEC VFD inverter to adjust the secondary air flow-rate based on requirements Extension of the conditions in which evaporative cooling can be used Air recirculation to avoid introducing contaminants Precise humidity control 6

LABEL WARNING!! Indirect free cooling + IEC combined with CRAC The solution involving IEC combined with traditional air-conditioning technology using perimeter Computer Room Air Conditioners Air recirculation to avoid introducing contaminants Ideal solution for retrofits in existing data centres Humidity control with adiabatic humidification Redundancy with two separate systems The system comprises an AHU that recirculates the air, cooling it via a heat recovery unit that exchanges heat with the outside air. This secondary air stream flows through the heat recovery unit without entering the data center. The evaporative cooler () reduces the secondary air temperature, while at the same time increasing its humidity up to 95%, guaranteeing maximum cooling of the recirculated air. The cooled air is delivered to the CRAC intake, thus significantly reducing airconditioner energy consumption. In this example, the AHU can handle a variable percentage of recirculated air, adapting the requirements of the application and the spaces available: all the air delivered to the CRAC can be pre-cooled, or just a portion of it, meaning more compact units and ducting. In winter, a second water spray humidifier () ensures precise supply humidity control, with a power consumption of just 4 W per litre of atomised water pco: management of the AHU components, CRAC units and supply temperature and humidity control optimist: guarantees humidity control and a considerable energy savings through IEC 4 VFD inverter to adjust the secondary air flow-rate based on requirements 6

4 Indirect water-side free cooling + IEC The solution for saving energy through evaporative cooling, however without modifying the air flows inside the data center, using traditional air-conditioning technology The system comprises perimeter CRAC units that control supply or server room temperature and humidity. chillbooster, installed on the dry cooler or the condenser, evaporatively cools the air intake and guarantees considerable energy saving by lowering the average refrigerant circuit condensing temperature. In CRAC systems with water-side economizers, i.e. fitted with a water coil that can be combined with an outdoor drycooler, chillbooster extends the period in which free cooling can be exploited, therefore considerably reducing the use of mechanical cooling. 4 pco: management of the CRAC units and supply temperature and humidity control ChillBooster: uses evaporative cooling to increase air-conditioning system efficiency KUE: controls air humidity inside the data centre power+: maximises direct expansion refrigerant circuit efficiency The use of DEC extends the period in which free cooling can be used. Energy saving as a result of lower condensing pressure Easy-to-install on existing systems Chill Booster 4

CAREL s 40 years experience in data centers Optimist Air can be effectively cooled by exploiting the evaporation of atomised water. 00 kg/h of water absorbs 69 kw of heat when evaporating, with power consumption of less than kw. ChillBooster Evaporative cooler for condensing units VFD Inverters represent a cutting-edge solution for modulating fan speed. KUE Steam humidification kit for close control units pco sistema+ Flexibility, connectivity, integration, energy saving. power+ Controller for compressors with permanent magnet brushless motors (BLDC/BLAC). humisonic Ultrasound humidification for close control units and fan coils humifog Adiabatic humidifiers offer significant advantages in terms of precise and efficient temperature and humidity management. CAREL INDUSTRIES 0 all rights reserved. CAREL INDUSTRIES reserves the right to modify the features of its products without prior notice. +000054EN -.0-09..0 Headquarters ITALY Sales organization Affiliates CAREL INDUSTRIES HQs Via dell Industria, 500 Brugine - Padova (Italy) Tel. (+9) 0499 766 Fax (+9) 0499 76600 carel@carel.com CAREL Asia - www.carel.com CAREL Australia - www.carel.com.au CAREL China - www.carel-china.com CAREL Deutschland - www.carel.de CAREL France - www.carelfrance.fr CAREL Iberica - www.carel.es CAREL India - www.carel.in CAREL HVAC/R Korea - www.carel.com CAREL Russia - www.carelrussia.com CAREL South Africa - www.carelcontrols.co.za CAREL Sud America - www.carel.com.br CAREL U.K. - www.careluk.co.uk CAREL U.S.A. - www.carelusa.com CAREL Czech & Slovakia - www.carel-cz.cz CAREL Korea (for retail market) - www.carel.co.kr CAREL Ireland - www.carel.com CAREL Thailand - www.carel.co.th CAREL Turkey - www.carel.com.tr All trademarks hereby referenced are the property of their respective owners. CAREL is a registered trademark of CAREL INDUSTRIES in Italy and/or other countries.