BD ISO 0/ (VDM ) ISO 0 ( mm) ISO 0 ( mm) Valves BDE = solenoid valves ISO 0/ with integrated connection including V DC coils and connector BDB = solenoid valves ISO 0/ with external connection with M connector including V DC coils and connector BD = valves and solenoid valves ISO 0/ (without coils and connectors to be ordered separately) TC TX Serial communication system available for BDE series Modular subbase ISOVDM Subbase with increased capacity TECHNICL CHRCTERISTICS mbient temperature Fluid temperature Fluid Commutation system Ways/Positions 0 0 C max 0 C 0 μm filtered and not dehumidified air, lubricated or not spool //, /, / control = max control = 0 max indirect electro,, pneumo mm =, mm = Nominal Ø (mm) Nominal flow rate (Nl/min) for valves and solenoid valves side mm Subbase in diecast aluminium according to standard Fittings: / / // Ø 00 00 00 Ø 0 0 0 Nominal flow rate (Nl/min) for valves and solenoid valves side Subbase in diecast aluminium according to standard Fittings: Ø 0 0 00 (b) Ø 00 00 00 Ø 0 0 0 (a) = manifold subbase valve places and end plates with side connections in aluminium and fixing plate for fittings standard supplied with subbase. (b) = manifold subbase valve place and end plates with side connections in aluminium and fixing plate for fittings standard supplied with subbase. (c) = the external Ø of the G / fitting for tube Ø mm must not exceed 0 mm Body valve Cover Seals Subbase ctuators Spool Electropilot Voltage Power consumption Protection degree Manual override / / // Ø 00 00 00 CONSTRUCTIVE CHRCTERISTICS ELECTRIC CHRCTERISTICS VDMISO Ø 0 00 0 Ø0 00 00 0 VDMISO Ø (c) 0 0 0 Ø 00 00 00 Ø 00 00 00 Oversize Oversize Ø0 00 00 0 Ø 00 0 0 (c) Ø 00 00 0 acetalic resin zamak nitrile rubber diecast alluminium technopolymer aluminium DD series (U0) V DC (± 0%), V DC upon request W IP with button with tool position Flow rate characteristics >> Valves and solenoid valves side mm / Oversize subbase for Ø mm tube Qn (Nl/min) 000 00 00 00 00 000 00 00 00 00 0 Qn (Nl/min) 00 000 00 000 00 000 00 000 00 >> Valves and solenoid valves side mm / Increased subbase for Ø mm tube 0 P = Working pressure P = Supply pressure Qn = Nominal flow rate P () P () P () P () Standardized valves _
BD ISO 0/ valves ISO 0 specifications They establish the dimensions of the bearing surface and the minimum distance between two valve places, guaranteeing the interchangeability and possibility to include any valve providing it complies with above specifications. >> Dimensioning of the bearing surface according to ISO 0/ specification with integrated connector Y = Min. distance between two interface axes of the same dimension mounting on the same manifolds U = Position bore, depth V mm mm,, B, D,, E 0 F G G G K,, L min. L min.,, LTE min. 0,, P 0, T M M U,, V W min. X, X,, Y 0 PIN connector Flying female connector Left supply plate G/ Subbase valve places for solenoid valve mm Plate for separating pressures Solenoid valve side mm Fittings according to UNIVER design Closing plate Fixing plate for fittings standard supplied with subbase 0 Intermediate supply plate G/ Interface for connecting valves side / mm Solenoid valve side mm Clamping fork for fittings Subbase valve place for solenoid valve mm Right supply plate G/ _0
BD ISO 0/ valves Codification key B D _ D Series Size Type BDE = solenoid valves with integrated connection V DC (including coil and connector) BDB = solenoid valves with integrated connection V DC, with M connector (including coil and connector) = side mm = side mm = / = / c.c. = / o.c. = / p.c. = // NCNC = // NCNO = // NONO Coil voltage = 0 = pneumo = V DC (standard) = = V DC (upon request) = = not Options D = externally servoassisted electropilot B D D Series Size Type BD = valves and solenoid valves (without coil and connectors to be ordered separately) = side mm = side mm = / = / c.c. = / o.c. = / p.c. = // NCNC = // NCNO = // NONO = = only DC = DC and C 0 = pneumo = = not = = only direct current = direct and alternating current = non only direct current = non direct and alternating current Options D = externally servoassisted electropilot Standardized valves >> Coils U0 side mm DD00 DD0 DD00 DD0 DD0 DD00 DD00 Nominal voltage DC v C v 0 0 Frequency HZ 0/0 0/0 0/0 0/0 Power consumption CCW C V rating start rating start,,,,,,,,,,,, LED connector M0/M0 V DC 0/0 Hz It can rotate by 0 on the coil IP cable connection PG o.c. = open centres c.c. = closed centres p.c. = pressurized centre _
BDE Solenoid valves with integrated connection Single impulse mm 0, En. Deen. / pneumo BDE0 Manual override /, BDE Double impulse mm 0, En. Deen. Manual override / 0, BDE / c.c., BDE / o.c., BDE / p.c., BDE / NC / NC BDE / NC / NO BDE / NO / NO BDE o.c. = open centres c.c. = closed centres p.c. = pressurized centres _
BDE Solenoid valves with integrated connection Single impulse mm 0,0 En Deen. / pneumo 0 BDE0 Manual override /, 0 0 BDE Double impulse mm 0, En. Deen. / / c.c. / o.c. / p.c. 0,,,, BDE BDE BDE BDE Manual override Standardized valves / NC / NC 0 BDE / NC / NO 0 BDE / NO / NO 0 BDE o.c. = open centres c.c. = closed centres p.c. = pressurized centres _
BDB Solenoid valves with M connector Single impulse mm 0, En. Deen. Manual override / pneumo BDB0 /, BDB Double impulse mm 0, Manual override / / c.c. / o.c. / p.c. 0,,,, En. Deen. BDB BDB BDB BDB ELECTRIC FETURES Central connector Mx IP protection degree V DC voltage, W nominal power DD0** series coil (without faston) ED 00% LED indicator vailable upon request other voltages max V DC / NC / NC BDB L R VDR VDR R L () () LTO LTO () / NC / NO BDB / NO / NO BDB o.c. = open centres c.c. = closed centres p.c. = pressurize centres _
BDB Solenoid valves with M connector Single impulse mm 0,0 En. Deen. Manual override / molla pneumo 0 BDB0 / molla, 0 0 BDB Double impulse mm 0, Manual override / / c.c. / o.c.,,, En. Deen. BDB BDB BDB ELECTRIC FETURES Central connector Mx IP protection degree V DC voltage, W nominal power DD0** series coil (without faston) ED 00% LED indicator / p.c., BDB vailable upon request other voltages max V DC / NC / NC 0 BDB L R VDR VDR R L () () LTO LTO () / NC / NO 0 BDB / NO / NO 0 BDB o.c. = open centres c.c. = closed centres p.c. = pressurize centres
BD ISO 0/ valves and solenoid valves Single impulse mm 0,0 En. Deen. Manual override / pneumo BD0 /, BD Double impulse mm 0, En. Deen. Manual override / 0, BD / c.c., BD / o.c., BD / p.c., BD / NC / NC BD / NC / NO BD / NO / NO BD o.c. = open centres c.c. = closed centres p.c. = pressurized centres BD solenoid valves are supplied without coils and connectors _
BD ISO 0/ valves and solenoid valves Single impulse mm 0, En. Deen. Manual override / pneumo 0 BD0 /, 0 0 BD Double impulse mm 0, En. Deen. Manual override / / c.c. / o.c. / p.c.,,,, BD BD BD BD Standardized valves / NC / NC 0 BD / NC / NO 0 BD / NO / NO 0 BD o.c. = open centres c.c. = closed centres p.c. = pressurized centres BD solenoid valves are supplied without coils and connectors _
BD ISO 0/ valves and solenoid valves Single/double impulse mm 0,0/0,0 En. Deen. / pneumo, 0 0 BD0 /, 0 BD / 0, 0 BD / c.c., 0 BD / o.c., 0 BD / p.c., 0 BD / NC / NC, 0 BD / NC / NO, 0 BD / NO / NO, 0 BD o.c. = open centres c.c. = closed centres p.c. = pressurized centres _
BD ISO 0/ valves and solenoid valves Single/double impulse mm 0,/0,0 En. Deen. / pneumo, 0 BD0 /, 0 BD /, 0 0 0 BD / c.c., 0 BD / o.c., 0 BD / p.c., 0 BD / NC / NC, 0 BD / NC / NO, 0 BD / NO / NO o.c. = open centres c.c. = closed centres p.c. = pressurized centres, 0 BD Standardized valves _
BDE Manifold subbases Integrated connection side mm B D C 0 Flying female connector Male connector Left supply plate G/ Fixing plate for fittings Straight fittings Plate for separating pressures Integrated connection Intermediate supply plate G/ Solenoid vale side mm Closing plate Subbase valve places Right supply plate G/ 0 Valve thickness B Subbase places valve C Closing plate for unused valve place BDF D Intermediate supply plate = Supply port = Use = Exhaust = = N = Number of valve places BDF00 BDF BDF0 BDF0TIM BDF0 BDF BDF0 left supply plate G/ with integrated connection weight: 0, Kg BDF0 (b) right supply plate G/ weight: 0, Kg intermediate supply plate G/ with integrated connection weight: 0, Kg BDF0 multiway connection module, poles male type D side mm weight: 0, Kg BDF0 (a) (b) (b) BDF0 (a) (b) plate for separating supply pressures weight: 0,00 Kg BDF00 plate for closing unused valve place weight: 0,0 Kg GZR00 interface for connecting valves side mm with integrated connection weight: 0, Kg GZRV000/0/0 sub base places according to VDMISO specifications flow rate 0 Nl/min G/ connections weight: 0, Kg _0 sub base places according to VDMISO specifications flow rate 0 Nl/min for fittings Ø mm weight: 0, Kg sub base places with increased capacity 00 Nl/min G/ connections weight: 0, Kg (a) = subbase including fixing plates for fittings (fittings excluded) sub base places with increased capacity 00 Nl/min for fittings Ø mm weight: 0, Kg single subbase place with increased capacity G/ connections weight: 0, Kg (b) = part no. codification: 0 = integrated screw plug weight: 0,0 Kg fittings according to UNIVER design (package 0 pcs.) GZRV000 Ø mm GZRV000 Ø mm GZRV000 Ø mm weight: 0,0 Kg each.
BDE Manifold subbases Integrated connection side mm B D C 0 Flying female connector Male connector Left supply plate G/ Clamping fork for fittings Straight fittings Plate for separating pressures Integrated connection Intermediate supply plate G/ Solenoid vale side mm Closing plate Subbase valve place Right supply plate G/ BDF00 BDF BDF0 BDF0TIM 0 BDF0 Valve thickness B Subbase place valve C Closing plate for unused valve place BDF D Intermediate supply plate = Supply port = Use = Exhaust = = N = Number of valve place BDF Standardized valves left supply plate G/ with integrated connection weight: 0, Kg right supply plate G/ weight: 0, Kg intermediate supply plate G/ with integrated connection weight: 0, Kg multiway connection module, poles male type D side mm weight: 0, Kg plate for separating supply pressures weight: 0,00 Kg plate for closing unused valve place weight: 0,0 Kg BDF0/0 (b) BDF0 (a) (b) BDF0/0(b) BDF0//(a) (b) BDF00 GZRVV00/0/0 sub base place according to VDMISO specification flow rate 0 Nl/min G/ connections BDF0 weight: 0, Kg G/ connections BDF0 weight: 0, Kg sub base place according to VDMISO specification flow rate 0 Nl/min for fittings Ø 0 mm BDF0 weight: 0, Kg (a) = subbase including fixing plates for fittings (fittings excluded) sub base place with increased capacity flow rate 00 Nl/min G/ connections BDF0 weight: 0, Kg G/ connections BDF0 weight: 0, Kg sub base place with increased capacity flow rate 00 Nl/min for fittings Ø 0 mm BDF0 weight: 0, Kg (b) = part no. codification: 0 = integrated single subbase place with increased capacity G/ connections weight: 0, Kg fittings according to UNIVER design (package 0 pcs.) GZRVV00 Ø mm GZRVV00 Ø mm GZRVV00 Ø 0mm weight: 0,0 Kg each. _
BD BDB Manifold subbases Electric connection with external connector side mm B D C Valve thickness B Subbase places valve C Closing plate for unused valve place BDF D Intermediate supply plate Left supply plate G/ Solenoid valve Straight fittings Plate for separating pressures Fixing plate for fittings Intermediate supply plate G/ Closing plate Subbase valve places Right supply plate G/ = Supply port = Use = Exhaust = = N = Number of valve places BDF0 BDF BDF BDF0 BDF BDF BDF00 left supply plate G/ weight: 0, Kg right supply plate G/ weight: 0, Kg intermediate supply plate G/ without integrated connection weight: 0, Kg plate for separating pressures weight: 0,00 Kg plate for closing unused valve place weight: 0,0 Kg interface for connecting valves side mm with integrated connection weight: 0, Kg GZRV000// single subbase place with increased capacity G/ connections weight: 0, Kg BDF0// (b) BDF0// (a) (b) BDF0// (b) BDF0// (a) (b) GZR00 DD0/.. sub base places according to VDMISO specifications flow rate 0 Nl/min G/ connections BDF0 BDF BDF weight: 0, Kg sub base places according to VDMISO specifications flow rate 0 Nl/min for fittings Ø mm BDF0 BDF BDF weight: 0, Kg sub base places with increased capacity 00 Nl/min attacchi G/ BDF0 BDF BDF weight: 0, Kg sub base places with increased capacity flow rate 00 Nl/min for fittings Ø mm BDF0 BDF BDF weight: 0, Kg screw plug weight: 0,0 Kg fittings according to UNIVER design (package 0 pcs.) GZRV000 Ø mm GZRV000 Ø mm GZRV000 Ø mm weight: 0,0 Kg cad. U0 coil side mm (for technical features refer to section ccessories>coils ) weight: 0,0 Kg (a) = subbase including fixing plates for fittings (fittings excluded) (b) = part no. codification: 0 = integrated = non integrated =only _
BD BDB Manifold subbases Electric connection with external connector side mm B C D Valve thickness B Subbase places valve C Closing plate for unused valve place BDF D Intermediate supply plate Left supply plate G/ Solenoi valve Straight fittings Plate for separating pressures Fixing plate for fittings Intermediate supply plate G/ Closing plate Subbase valve place Right supply plate G/ BDF0 BDF BDF BDF0 BDF = Supply port = Use = Exhaust = = N = Number of valve places BDF00 left supply plate G/ weight: 0, Kg right supply plate G/ weight: 0, Kg left supply plate G/ without integrated connection weight: 0, Kg plate for separating supply pressures weight: 0,00 Kg plate for closing unused valve place weight: 0,0 Kg single subbase place with increased capacity G/ connections weight: 0, Kg Standardized valves BDF0/.. (b) BDF0// (a) (b) BDF/.. (b) BDF0// (a) (b) GZRVV00//0 DD0/.. sub base place according to VDMISO specification flow rate 0 Nl/min G/ connect. G/ connect. BDF0 BDF0 BDF BDF BDF BDF sub base place according to VDMISO specification flow rate 0 Nl/min for fittings Ø 0 mm BDF0 BDF BDF weight: 0, Kg sub base place with increased capacity 00 Nl/min G/ connect. G/ connect. BDF0 BDF0 BDF BDF BDF BDF weight: 0, Kg weight: 0, Kg sub base place with increased capacity 00 Nl/min for fittings Ø 0 mm BDF0 BDF BDF weight: 0, Kg fittings according to UNIVER design (package 0 pcs.) GZRVV00 Ø mm GZRVV00 Ø mm GZRVV00 Ø 0mm weight: 0,0 Kg cad. U0 coil side mm (for technical features refer to section ccessories>coils ) weight: 0,0 Kg (a) = subbase including fixing plates for fittings (fittings excluded) (b) = part no. codification: 0 = integrated = non integrated = only _
BD Connection modules and flying connectors table of connections Electric connection M0 TSCFNS000 TSCFNS000 TSCFNS000 TSCFNS000 TSCFND000 TSCFND000 TSCFND000 mm connector BDF0 TIM famale connector poles type Dsub no cable M x fixing screws BDF0 TIM famale connector poles type Dsub cable 0 m M x fixing screws male/famale flying connector sub D (upon request) prewired for coils with cable Ø mm (0 m lenght) suitable for mobile laying M x fixing screws multiway connection module poles male type D side mm multiway connection module poles male type D side mm >>Colour identification according to standard DIN 00 Female connector DSUB poles for connection coils PIN No. side Valve N Colour Coil 0 0 0 0 white brown green yellow grey pink blue red black violet greypink redblue whitegreen greenbrown whiteyellow yellowbrown whitegrey greybrown whitepink pinkbrown whiteblue brownblue whitered brownred brownblack shield whiteblack 0 0 common low _