I.T BSV-N series 25 ELECTROMECHANICAL TURRETS TECHNICAL INFORMATION ISSUED

Size: px
Start display at page:

Download "I.T. 6430. BSV-N series 25 ELECTROMECHANICAL TURRETS 09-08 TECHNICAL INFORMATION ISSUED"

Transcription

1 series 25 ELECTROMECHANICAL TURRETS TECHNICAL INFORMATION I.T. 643 GB The data given in the I.T. are subject to technical modifications without notice. ISSUED 9-8

2 WORKING PRINCIPLE Water-proof housing with oil immersed mechanism, life lubricated. Clamping on 3-part Hirth front toothing High stifness and accuracy No lifting during rotation. F D E B Single three-phase electric motor for rotation and clamping. A L N I G M P H C Main overall dimensions and fixings interchangeable with previous series and SM turrets. A) Electrical motor (three-phase) B) Gearbox C) Rotation and cam locking mechanism D) Pre-indexing solenoid E) Pre-indexing control switch F) Shock-absorber system G) Preloaded locking spring H) 3-parts front coupling I ) Locking control switch L) Angular position transmitter (absolute) M) Rotating plate N) Coolant flange P) Quick change coolant valve I.T B-2

3 CHARACTERISTICS AND PERFORMANCES Technical data Size 2/25 6/25 2/25 25/25 32/24 4/2 Tool stations N Version () std slow very slow fast std slow std slow very slow std slow std slow std slow very slow Inertia of transportable mass Kgm 2,45,8,2,55,9,8 3 4, Indexing time (including locking) 3 s,4,48,58,4,48,58,65,78,78,,25,25,45 2,5 45 s,48,57,69,48,57,69,78,94,8,94,8,25,45,45,65 2,5 8 s,6,38,65,6,38,65,83 2,23 2,8 2,23 2,8 2,7 3,8 3,8 3,66 5,53 Rotating time only 3 s,5,8,2,5,8,2,24,3,36,3,36,33,38,38,45,68 45 s,23,27,32,23,27,32,36,45,54,45,54,49,58,58,67 Indexing frequency a9 cycle/min Electric supply See wiring diagram Mass (without disc) ~ Kg Ambient temperature range C Coolant supply: Costant flow bar Pressure cut-off during turret rotation Protection degree (DIN 45) bar IP65 IP65 IP65 IP65 IP65 IP65 () Other versions on request. Filtering 5 µm. I.T B-3

4 CHARACTERISTICS AND PERFORMANCES Accuracy,/, A α β, A Repeatibility accuracy α ±,6" (,78 µm/ mm) Indexing accuracy β ± 4" (,9 µm/ mm) Loading capacity b F Max. tangential torque Fxb Nm b F2 Max. tilting torque (to push) F2xb Nm b F3 b Max. tilting torque (to lift) F3xb Nm P Unbalancing torque P x b Nm I.T B-4

5 DUTY PERFORMANCES F [N] Tangential force F b F b [mm] The diagram refers to F values which cause elastic yelding within the rates shown in the schedule. Turret size Max. elastic yelding mm,5,7,8,4,2,6 Distance from centre of measuring point mm F2 [N] Tilting force (to push) F2 2 2 b b [mm] I.T B-5

6 DUTY PERFORMANCES F3 [N] Tilting force (to lift) F b b [mm] F4 [N] Radial tilting force F4 a a [mm] I.T B-6

7 PARAMETERS FOR TURRET SELECTION S: CHIP CROSS-SECTION (max) for steel R 6 N/mm 2 Ks 2.2 N/mm 2 N: POWER (max) for Vt 2 m/min N [kw] S [mm 2 ] b ,8,6, b [mm] For any material with different Ks: Sx S X 2.2 Kx For different cutting speeds: Nx N X Vtx 2 I.T B-7

8 2/25 OVERALL DIMENSIONS PG 3,5 (8) () /4" GAS 3 ø75 ø2 ø3 h ø5 g6 52 (6) ,5 2 N M2 (for lifting) x45 22 max 25 +, 63 (5) (4) 2 M8x POS. VERSION 8 POS. VERSION TOOL DISC INTERFACE (7),4 ~,2 OR 25,8 for M8 ø8 ø3 Js6 ø ø min ø8 max ø85 ) Inlet coolant position, at choise. 2) Right or left coolant outlet position. 3) Adjustable coolant ring. 4) Coolant outlet displacement range. 5) Soft surface for boring the disc reference pins. 6) Reference pin to be positioned on both side, at choise. 7) Reference pins between tool disc and turret. 8) Electrical connections on both side, at choise. Important: The connection cable must be provided with fittings and gaskets in order to avoid penetration of water into the turret. I.T B-8

9 6/25 OVERALL DIMENSIONS PG 3,5 (8) () /4" GAS 55 ø25 ø32 ø4 h ø7 g6 49 (6) N M2 (for lifting) , x45 22 max 237 +, 8 (5) (4) 2 M8x5 2 2 POS. VERSION 8 POS. VERSION TOOL DISC INTERFACE (7),4 ~,2 OR 25, for M ø ø4 Js6 min ø5 max ø ø ø6 ) Inlet coolant position, at choise. 2) Right or left coolant outlet position. 3) Adjustable coolant ring. 4) Coolant outlet displacement range. 5) Soft surface for boring the disc reference pins. 6) Reference pin to be positioned on both side, at choise. 7) Reference pins between tool disc and turret. 8) Electrical connections on both side, at choise. Important: The connection cable must be provided with fittings and gaskets in order to avoid penetration of water into the turret. I.T B-9

10 2/25 OVERALL DIMENSIONS PG 3,5 (8) () 3/8" GAS 2 (5) ø252 ø62 ø5 h5 3 27,5 28 +, 45 2 (4) 2 ø2 g (6) 35 Mx POS. VERSION 8 POS. VERSION N M2 (for lifting) TOOL DISC INTERFACE 22 2 (7),4 ~, max,8 OR for M2 ø2 ø5 Js6 min ø3 max ø4 ø ø6 ) Inlet coolant position, at choise. 2) Right or left coolant outlet position. 3) Adjustable coolant ring. 4) Coolant outlet displacement range. 5) Soft surface for boring the disc reference pins. 6) Reference pin to be positioned on both side, at choise. 7) Reference pins between tool disc and turret. 8) Electrical connections on both side, at choise. Important: The connection cable must be provided with fittings and gaskets in order to avoid penetration of water into the turret. I.T B-

11 25/25 OVERALL DIMENSIONS PG 3,5 (8) () 3/8" GAS 25 (5) ø3 ø22 ø63 h5 27, , (4) 2 35 ø26 g6 2 (6) M2x POS. VERSION 8 POS. VERSION N M2 (for lifting) TOOL DISC INTERFACE (7),4 ~, OR max, for M6 ø6 ø ø63 Js6 ø6 min ø7 max ø75 ) Inlet coolant position, at choise. 2) Right or left coolant outlet position. 3) Adjustable coolant ring. 4) Coolant outlet displacement range. 5) Soft surface for boring the disc reference pins. 6) Reference pin to be positioned on both side, at choise. 7) Reference pins between tool disc and turret. 8) Electrical connections on both side, at choise. Important: The connection cable must be provided with fittings and gaskets in order to avoid penetration of water into the turret. I.T B-

12 32/24 OVERALL DIMENSIONS 267 PG 3,5 (8) () 3/8" GAS 325 (5) ø39 ø27 ø8 h , (4) 2 38 ø32 g (6) M2x POS. VERSION 8 POS. VERSION N 2 M6 (for lifting) TOOL DISC INTERFACE (7) OR max 2,2 ~,2,8 ø for M2 ø6 ø8 Js6 ø3 ø32 min ø7 max ø22 ) Inlet coolant position, at choise. 2) Right or left coolant outlet position. 3) Adjustable coolant ring. 4) Coolant outlet displacement range. 5) Soft surface for boring the disc reference pins. 6) Reference pin to be positioned on both side, at choise. 7) Reference pins between tool disc and turret. 8) Electrical connections on both side, at choise. Important: The connection cable must be provided with fittings and gaskets in order to avoid penetration of water into the turret. I.T B-2

13 4/2 OVERALL DIMENSIONS 6 23 PG 3,5 (8) () /2" GAS (4) +, ø355 ø h5 478, (5) ø36 47 ø4 (6) N 2 M24 (for lifting) TOOL DISC INTERFACE T-Nut M2 DIN 58 (7) max, for M24 M2 ø6 ø Js6 min ø245 max ø255 ø ø22 ) Inlet coolant position, at choise. 2) 4 coolant outlet position. 3) Coolant valve. The valve can be fitted on one of the 4 coolant outlet position. The drawing represents how the valve is positioned when the disc is mounted. Without the disc, the valve produtes by 2 3 mm is comparison with the position indicated. 4) Coolant outlet displacement range. 5) Soft surface for boring the disc reference pins. 6) Reference pin to be positioned on both side, at choise. 7) Reference pins between tool disc and turret. 8) Electrical connections on both side, at choise. Important: The connection cable must be provided with fittings and gaskets in order to avoid penetration of water into the turret. I.T B-3

14 I.T B-4

15 WIRING DIAGRAM ~ WIRING NUMBER REF. COMPONENT CHARACTERISTICS SIMBOLS COLOUR SIGNALS ELECTRIC MOTOR (three-phase) () V 5/6 Hz For other characteristics see Tab. ~ 3 U V W U2 V2 W2 WHITE GREEN BLACK WHITE GREEN BLACK See Tab. 2 2 THERMAL DETECTOR 35 C,5A 25V 2 BROWN BROWN 3 BRAKE 24 V D.C. 2/6 8 W 2/4 2 W 3 4 GREEN GREEN 4 INDEXING SOLENOID 24V D.C. 44 W 5 6 BLUE BROWN 5 INDEXING CONTROL SWITCH 6 LOCKING CONTROL SWITCH 24V D.C. ± % 2 ma (load) OUTPUT-PNP-NO BROWN BLACK BLUE BROWN BLACK BLUE + V D.C. EXIT V D.C. + V D.C. EXIT V D.C. 7 ANGULAR POSITION TRANSMITTER (ABSOLUTE) 24V D.C. ± % 35 ma (supply) 5 ma/exit (load) OUTPUT-PNP BROWN BLUE WHITE YELLOW GREEN VIOLET BLACK PINK + V D.C. V D.C. Bit Bit 2 Bit 3 Bit 4 Strobe Parity check GREEN / YELLOW PE ELECTRIC MOTOR CHARACTERISTICS Tab. ELECTRIC MOTOR'S WIRING () Tab. 2 Turret size Minimum required power Short circuit power 2/6 KVA, KVA,6 2/25 KVA,8 KVA 2,8 32/4 KVA 2,6 KVA 3,8 U V W U2 V2 W2 WIRING Y (38 V) U V W U2 V2 W2 WIRING (22 V) () Other voltages on request. The termal detector gives a signal only motor overheating. I.T B-5

16 CYCLE POS. (START) POS. 2 Locked turret POS. 2 Locked turret T T POS. 2 (START) T2 POS. T2 NOTE : ELECTRIC MOTOR CW CCW R2 R2 For the T-T2-R-R2 value see Tab. 2 3 BRAKE R R 4 INDEXING SOLENOID Indexing pin mech. position 5 INDEXING CONTROL SWITCH 6 LOCKING CONTROL SWITCH 7 ANGULAR POSITION TRANSMITTER (ABSOLUTE) BIT 2 BIT 3 BIT 4 BIT PARITY CHECK STROBE For position code see Tab. Tab. FUNCTION POSITIONS BIT 2 BIT 3 BIT 4 BIT PARITY CHECK STROBE CW CCW Tab. 2 TURRET SIZE PROGRAMMING TIME ALLOWED LAG TIME MAX T (ms) T2 (ms) R (ms) R2 (ms) Standard and fast Slowed Standard Slow and very slow I.T B-6

17 CYCLE DESCRIPTIONS. Signals To get a change of positions on the turrets, the control equipment (usually a N.C. equipment) must control the components mentioned below according to a well defined sequence (see wiring diagram on page 5). Motor () Brake Indexing solenoid (4) The following output signals from the turret are provided for driving the positioning cycle: Angular position given by the angular position transmitter (7) Indexing control switch (5) Locking control switch (6). Flow chart TURRET START CYCLE YES DE-ENERGIZE BRAKE AND SET ROTATION. Description of the operating sequence This description refers to sequence cycle: the first part gives the sequence to pass from position to position 2 with clockwise rotation, the second part gives the sequence to pass from position 2 to position 2 with counterclockwise rotation. As indicated by the cycle, the controls are to be performed according with the following sequence: De-energize the brake and start motor rotation in the desired direction. If, as in the case shown by the diagram, the next position (pos. 2) is the Stop position, when the strobe signal reached a zero level, the solenoid (4) is to be energized. In case of passage from position 2 to position 2, wait for the reading signaling the passage on pos. then, since the next one is the Stop position, wait until the next strobe signal reaches a zero level and (at that time only) energize the solenoid (4). N.B.: The maximum lag time between the reading of the strobe signal and the excitation of the solenoid (4) cannot exceed the R values indicated in the table. The turret goes on rotating until the indexing pin, pushed by the solenoid (4), enters into the mechanical stop slot. This movement is detected by the sensor (5) which must immediately stop the motor that, once expired the T time will re-start rotating in the opposite direction. During this phase the turret is locking and its locked position is detected by the sensor (6) and this signal is used to stop the motor (). The maximum lag time between the signal of the sensor and the stopping of the motor must never exceed the R2 value shown in the table. At this point the machine can be started, in order to go on working. The solenoid (4) is to be de-energized after the expiration of the T2 lag time starting from the moment when the sensor (6) signal is read. NO NO NO BEFORE GOAL POSITION-STROBE YES SET INDEX max. allowed lag time R ( * ) INDEX CONTROL SWITCH YES STOP ROTATION SET TIMER T ( * ) DELAY TIMER T EXPIRED SET REVERSE ROTATION N.B.: The T, T2, R, R2 times must be understood as real times execution of the controls and the signals checked on the terminal board of the turret. For an accurate detection and measurement of the above mentioned values it is advisable to use adeguate instrumentation such as an oscilloscope with memory and current sensing devices. NO LOCKING CONTROL SWITCH YES STOP MOTOR max. allowed lag time R2 ( * ) YES CONCIDENT POSITION YES START TO THE MACHINE WORK NO FAULT SET BRAKE ( ) See tab. 2 sheet 6 (Cycle). * I.T B-7

18 "PA" VERSION TURRETS (with axial throught-bore) A ød Turret size ; ø D A DRIVEN TOOLS SYSTEM " *" turrets have been designed for modular fitting onto the different driven tool systems. BS * -DT With ODT-N driven tool device. Tool coupling according to DIN 89. Tool disc with axial seats. Front machining. ; 6 BS * -TR With IDT-R driven tool device. Tool disc with radial seats. Front machining. NOTE: Front and back machining for sub-splinde machines is also available on request. For further information please contact our Technical Dept. I.T B-8

19 UCN CONTROL UNIT The UCN control unit manages the moving cycle of turret in a simple and optimized way: simple and optimized software; no memory positions are occupied in the machine control; automatic chose of the shortest path; steady monitored for faults. For other information see the Technical Information UCN- *. IDENTIFICATION CODE * - * - * /2 * - * - * - ( * ) SIZE CODE OPTIONALS AXIAL THROUGH BORE CODE Without (Standard) With (Optional) PA CODE FREQUENCY and INERTIA 5 H 5 Hz Fast 6 H 6 Hz Fast 5 5 Hz Standard 6 6 Hz Standard 5 L 5 Hz Slow 6 L 6 Hz Slow 5 LL 5 Hz Very slow 6 LL 6 Hz Very slow POSITIONS CODE Nr. 8 Pos. 8 Nr. 2 Pos. 2 SERIE 2 29 () MOTOR VOLT. and FREQUENCY V - 5/6 Hz V - 5/6 Hz V - 5/6 Hz () From 2 to 29 the performance and the overall dimensions do not change. I.T B-9

20 DUPLOMATIC AUTOMATION S.r.l. 225 LEGNANO (MI) - ITALY P.LE BOZZI, PHONE 33/472 FAX 33/ info@duplomatic.it come visit Duplomatic homepage:

Tool Turrets and Tool Discs

Tool Turrets and Tool Discs Our other products Automatic Tool Changer Chucking Cylinders Tool Discs Indexing Tables Tool Turrets and Tool Discs Pragati Automation Pvt. Ltd. 1, IV Phase, 11th Cross, Peenya Industrial Area Bangalore

More information

Quick Reference Catalog

Quick Reference Catalog Gearboxes Turrets Y-Axis Rotary Tools Tool Discs B-Axis Quick Reference Catalog WWW.BARUFFALDI.IT TB Servo Turret SERVO MOTOR TURRETS TB-type turrets rotate thanks to a BRUSHLESS SERVO MOTOR controlled

More information

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output. Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling

More information

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig Through hollow shaft Ø 5 bis 4 mm Outside diameter only 76 mm Easy installation by means of clamping ring front or rear Operating temperature up to 00 C Applications: motors, printing machines, lifts NUMBER

More information

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529) Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall

More information

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall

More information

Series 6000 Torque measured metal bellow coupling

Series 6000 Torque measured metal bellow coupling Properties Free of float metal bellow coupling with integrated torque measurement Non-contact measurement system, high robustness High torsional stiffness Limited torque of inertia Performance Measurement

More information

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51 83 300/100 ED E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP P05 p max 250 bar Q max (see specification table) MOUNTING INTERFACE OPERATING PRINCIPLE

More information

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T Universal industry standard encoder Up to 40 000 steps with 0 000 pulses High signal accuracy Protection class up to IP67 Flexible due to many flange and configuration variants Suitable for high shock

More information

TECHNICAL DATASHEET Incremental Encoder RI 58-H

TECHNICAL DATASHEET Incremental Encoder RI 58-H Through hollow shaft High accuracy by means of integrated flexible coupling Safe shaft mounting Applications: textile machines, motors, drives, copiers NUMBER OF PULSES 1 / 2 / 3 / 4 / 5 / 10 / 15 / 20

More information

Description. Dimensions. Features. www.pwb-encoders.com. precision works better

Description. Dimensions. Features. www.pwb-encoders.com. precision works better Description The MEC22 is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square wave outputs in quadrature

More information

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads: Automation / Mini Type SCH32F Hollow Shaft Encoder - Ø 32 mm Hollow Bore: Ø 6 mm to Ø 3/8 inch Resolution up to 5000 ppr IP 65 (IP 50 for IDC connector option) Electrical Specifications Code: Resolution:

More information

+ Incremental interface

+ Incremental interface i IEH58-INC-1-GB-1 04/12 Revision 01 010101-00589999-9999 + Incremental interface + Type with hollow through shaft + Modular product line + Extensive parameter setting possibilities + Special parameters

More information

3-Component Measuring System

3-Component Measuring System Force 3-omponent Measuring System for utting Force Measurement During Turning Modular system for measurement of cutting forces when turning outside and inside diameters on turret lathes. Machine adapters

More information

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants Sendix 5000 / 500 (Shaft / Hollow shaft) Push-Pull / RS4 ue to their sturdy bearing construction in Safety-ock esign, the Sendix 5000 and 500 offer high resistance against vibration and installation errors.

More information

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181 Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.

More information

Speed Control Relays SX2

Speed Control Relays SX2 SX2 File 850 CONENS Description.....................................................Page General Information................................................ 2-3 SX2DV General Information...........................................

More information

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve 9700 NAMUR series, / & / > > Port size: G/, / NPT, NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve > > Manual

More information

How To Power A Schen

How To Power A Schen Automation / Mini Type SCH32F Hollow Shaft Encoder - Ø 32 mm Hollow Bore: Ø 6 mm to Ø 3/8 inch Resolution up to 5000 ppr IP 65 (IP 50 for IDC connector option) Electrical Specifications Code: Resolution:

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

Series 7500 Torque Sensor

Series 7500 Torque Sensor Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Plug & Play solution, no additional electronics required Performance Measurement

More information

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment

More information

Electronic Pressure Switch EDS 3000

Electronic Pressure Switch EDS 3000 For Your Information Electronic Pressure Switch EDS 3000 User Manual Revision: November 01, 2002 1. EDS 3000 Functions The EDS 3000 unit offers the following functions: Display pressure in psi, MPa, or

More information

Tool Holder Catalog INDEX ABC VDI 25 LL3602.30051-10.04.2014. 0414/Rö

Tool Holder Catalog INDEX ABC VDI 25 LL3602.30051-10.04.2014. 0414/Rö Tool Holder Catalog INDEX ABC VDI 25 LL3602.30051-10.04.2014 0414/Rö Disclaimer The illustrations in this documents may deviate from the delivered product. We reserve the right to make changes due to errors

More information

industrial drive systems AC LINE Spring-applied single-disc brake 73 341..A00 73 431..H00 73 241..E00 / 73 245..E00

industrial drive systems AC LINE Spring-applied single-disc brake 73 341..A00 73 431..H00 73 241..E00 / 73 245..E00 industrial drive systems AC LINE Spring-applied single-disc brake 73 341..A00 73 431..H00 73 241..E00 / 73 245..E00 AC LINE Kendrion (Aerzen) GmbH, Germany Kendrion (Villingen) GmbH, Germany Kendrion Magnetic

More information

1115 4G SERIES GOVERNOR. 4-20 ma ANALOGUE DIGITAL SPEED SETTING

1115 4G SERIES GOVERNOR. 4-20 ma ANALOGUE DIGITAL SPEED SETTING 1115 4G SERIES GOVERNOR with 4-20 ma ANALOGUE & DIGITAL SPEED SETTING PO Box 28, 9300AA Roden, The Netherlands Tel: +31 505019888 Fax: +31 505013618 E-mail: regulateurs@regulateurs-europa.com 1115 4G

More information

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61 Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:

More information

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic

More information

Highly flexible couplings

Highly flexible couplings Construction and operation 8.03.00 Instructions for installation 8.03.00 Types of stress 8.04.00 Diagrams for static deformation of the coupling ring 8.05.00 Coupling size 8.07.00 Examples of combinations

More information

D.C. Motors. Products and specifications subject to change without notice.

D.C. Motors. Products and specifications subject to change without notice. D.C. Motors Order/Technical Support - Tel: (8) 677-5 / FAX: (8) 677-865 / www.crouzet-usa.com / DC Motors Selection guide Gearbox Speed Torque max (Nm).5. Type of Gearbox 8 8 8. Power usable (w) Torque

More information

Pressure and flow control system

Pressure and flow control system Pressure and flow control system RE 30030/04.09 1/32 Replaces: RE 30024/11.03 RE 30027/06.04 RE 30030/01.04 Type SYDFE1, SYDFEE, SYDFEC, SYDFEn Size 18 to 140 Component series 2X Maximum operating pressure

More information

Harmonic Drive acutator P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l

Harmonic Drive acutator P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l D C S e r v o S y s t e m s RH Mini Series Total Motion Control Harmonic Drive acutator P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l Precision Gearing & Motion Control DC SERVO ACTUATORS

More information

Rotary actuators Rotary wing drives Series RAK. Brochure

Rotary actuators Rotary wing drives Series RAK. Brochure Brochure 2 Rotary wing drives, angle of rotation: 30-270 Rotary wing drive, double-acting axis geometry: single 4 Rotary wing drives, angle of rotation: 90-270 Rotary wing drive, double-acting axis geometry:

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

PLQE. The base of the economy gearboxes with square output flange. Economy Line. Formerly PLE

PLQE. The base of the economy gearboxes with square output flange. Economy Line. Formerly PLE 20 ormerly PL The base of the economy gearboxes with square output flange The PL series with square output flange. A powerful alternative for additional higher radial and axial loads. Low backlash High

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8 System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures

More information

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5 Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis

More information

Vario Line. Spring pressure single-disc brake 76 431..H00

Vario Line. Spring pressure single-disc brake 76 431..H00 Vario Line Spring pressure single-disc brake 76 431..H00 Vario Line Industrial Drive Systems Die Welt von Kendrion Industrial Drive Systems Kendrion the brake experts As a solution provider, Kendrion develops,

More information

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32 www.atos.com Table F040-1/E Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32 AGMZO are two stage poppet type proportional

More information

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium

More information

Ball Rail Tables TKK. with Ball Rail Systems and Ball Screw Drive R310EN 2501 (2008.04) The Drive & Control Company

Ball Rail Tables TKK. with Ball Rail Systems and Ball Screw Drive R310EN 2501 (2008.04) The Drive & Control Company with Ball Rail Systems and Ball Screw Drive R310EN 2501 (2008.04) The Drive & Control Company Bosch Rexroth AG Linear Motion and Assembly Technologies Ball Rail Systems Roller Rail Systems Linear Bushings

More information

Smoke exhaust systems

Smoke exhaust systems 1 Fire zone, e.g. hall 2 Smoke exhaust zone, separated by smoke curtains Natural and mechanical smoke extraction General information 3 Natural smoke and heat exhaust vent 4 Air inlet opening or wake max.

More information

Addendum to the Operating Instructions

Addendum to the Operating Instructions Drive Technology \ Drive Automation \ System Integration \ Services Addendum to the Operating Instructions MOVIMOT with AS-Interface and AC Motor DT/DV Unit Replacement MOVIMOT MM..C -> MM..D with MLK3A

More information

Line-Mounted Valves L Series

Line-Mounted Valves L Series Spare Part Kit for Valve Series B1LSAD3 Line-Mounted L Series Accessories Spare Part Kits All Series Valve Series B1LSAD3 40.1609 Incl. O-rings, gaskets, spring or muffl er Spare Part Kit for Valve Series

More information

DUGARD. Machine Tools Since 1939. Dugard 700L Series Heavy Duty CNC Lathes. www.dugard.com

DUGARD. Machine Tools Since 1939. Dugard 700L Series Heavy Duty CNC Lathes. www.dugard.com DUGARD Machine Tools Since 1939 Dugard 700L Series Heavy Duty CNC Lathes www.dugard.com Dugard 700L Heavy Duty CNC Lathe 2000, 3000 or 4000mm bed length Designed for easy and convenient operation The concave

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large

More information

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs. TXV - Presentation pumps with Load Sensing control variable displacement piston pumps ADVANTAGES pumps are variable displacement with pressure-flow control called Load Sensing. They self-regulate to give

More information

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7 Ø 5 ±. DC Electropumps Bull,5 Rotation,5 5,7 Email: sales@hydronit.com Fax B... Electro pumps Bull series MODEL CODE EPB,5 DC /S5 K, V** Electro Pump Bull series Gear pump displacement (cc/rev (see tables

More information

Reaction Torque Sensor

Reaction Torque Sensor Force 1 1 N m up to 1 000 1 000 N m Type 9329A 9389A These easy to install piezoelectric reaction torque sensors are particularly suitable for measuring rapidly changing torques at non-rotating shafts.

More information

Pressure transmitter For general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information

Centro-Matic Automatic Lubrication Systems System Controls

Centro-Matic Automatic Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

Torque motors. direct drive technology

Torque motors. direct drive technology Torque motors direct drive technology Why Direct Drive Motors? Fast and effective Direct-drive technology in mechanical engineering is defined as the use of actuators which transfer their power directly

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

Solenoid valves Type EVU

Solenoid valves Type EVU Data sheet Solenoid valves EVU EVU solenoid valves are designed to fit into compact refrigeration systems. Available in direct and pilot operated versions, they can be applied in liquid, suction, and hot

More information

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049

More information

SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents

SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents English translation of German original Technical Information TI-P11 SITEMA PowerStroke Mould Closing Devices series FS drive system for powerful forces on a short stroke hydraulic actuation closing force

More information

LENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space

LENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space LENORD +BAUER... automates motion. Technical information Version 2014-09 General The PowerDRIVE-Positioning

More information

Number 1 in efficiency

Number 1 in efficiency PowerXL DE1 Variable Speed Starter www.eaton.eu/de1 Number 1 in efficiency The easiest way of variable motor speed NEW Variation DE11 The new device category! The PowerXL DE1 Variable Speed Starter Why

More information

maxon sensor maxon sensor

maxon sensor maxon sensor Sensor Spindle drive Gearhead E Motor (BLD Motor) D Motor X Drives (configurable) Motor control obust encoders, D tachometers, and resolvers with high accuracy and high signal resolution. Due to resonance,

More information

TELESCOPE Motorized Lighting Suspension

TELESCOPE Motorized Lighting Suspension TELESCOPE Motorized Lighting Suspension Mod. 8400 FEATURES The De Sisti TELESCOPE is a single point suspension specifically designed to provide rigidity and stabilization of all moving parts. It can extend

More information

Operating instructions Diffuse reflection sensor. OJ50xx 701396 / 01 07 / 2004

Operating instructions Diffuse reflection sensor. OJ50xx 701396 / 01 07 / 2004 Operating instructions Diffuse reflection sensor OJ50xx 7096 / 0 07 / 004 Contents Preliminary note. Symbols used Function and features Installation. Installation of the supplied mounting fixture 4 4 Electrical

More information

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc Ultrasonic sensors for high precision detection of clear and transparent objects Clear object detection, inspection on transparent or highly reflective film and liquid level measurement Standard M18 tubular

More information

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output

More information

Digital display DA 48

Digital display DA 48 Loop powered plug-in LCD display No auxiliary energy source needed Scale freely adjustable on site Can be turned to any position Suitable for any 0 ma transmitter with EN 175301-803A connector Digital

More information

PM734F - Technical Data Sheet Winding 28

PM734F - Technical Data Sheet Winding 28 - Technical Data Sheet Winding 28 SPECIFICATIONS & OPTIONS STANDARDS STAMFORD AC generators are designed to meet the performance requirements of IEC EN 60034-1. Other international standards, including

More information

Borstlösa DC-motorer. Promoco Scandinavia AB

Borstlösa DC-motorer. Promoco Scandinavia AB Borstlösa DC-motorer Promoco Scandinavia AB BL Series Brushless DC Motors with Integral Drive 24, 54, 68, and 70 mm diameters, 2W up to 110W output power Allied Motion s BL series of small brushless DC

More information

Plug and Socket Devices CES 63 A Series 8579

Plug and Socket Devices CES 63 A Series 8579 www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

BoWex SD, SD1 and SD2 Operating-/Assembly Instructions

BoWex SD, SD1 and SD2 Operating-/Assembly Instructions D-807 Rheine 0111 E 1 curved-tooth gear couplings are flexible shaft connections. They are able to compensate for shaft displacement caused by, as an example, inaccuracies in production, heat expansion,

More information

2/2 and 3/2 Way Size 6 Seat Valves

2/2 and 3/2 Way Size 6 Seat Valves 2/2 and 3/2 Way Size 6 Seat Valves Directly operated Interface and subplate dimensions according to DIN 24340 and ISO Line connection port size G 3/8" Cartridge design PN [p max. ] = 315 bar 7501856.06.12.08

More information

A10VSO Nominal size 18 see RD 92712 A10VSO Nominal size 28...140 see RD 92711

A10VSO Nominal size 18 see RD 92712 A10VSO Nominal size 28...140 see RD 92711 A10VO Nominal size 18 see RD 92712 A10VO Nominal size 28...140 see RD 92711 The variable displacement axial piston pump A10VO in swashplate design was designed for hydrostatic drives in open circuits.

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports

More information

MDC151-024031 Series

MDC151-024031 Series MDC151-024031 Series 24V, 3A Brushless DC Controller User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714)

More information

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information

Data Sheet. Electro-mechanical counters Hengstler 800 series

Data Sheet. Electro-mechanical counters Hengstler 800 series Data Pack D Issued March 00 504897 Data Sheet Electro-mechanical counters Hengstler 800 series The 800 series totalising and predetermining batch counters, manufactured by Hengstler, is available from

More information

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8). DS3002 1. General Description This data sheet describes the Modular Power (MP) Electro Hydraulic Power Units, which have been designed to provide an advanced and flexible means of brake control. The MP

More information

W150: Miniature photoelectric switch series with completely integrated electronics

W150: Miniature photoelectric switch series with completely integrated electronics Product group W50 Photoelectric proximity switch BGS Photoelectric proximity switch energ. Photoelectric reflex switch W50: iniature photoelectric switch series with completely integrated electronics Through-beam

More information

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands: Oil & Gas / Heavy Industry EX-Proof Stainless Steel Shaft Encoder - Ø 68 mm Shaft - Ø 10 mm to Ø 5/8 inch Resolution up to 10,000 ppr IP 66 (IP 67 option) ATEX certified EX-Proof IECEx certified EX-Proof

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

Brushless DC Motors Intro duction BLF BLU BLH Installation. Brushless DC Motors. DC Input. AC Input DC Input. BLH Series. Page. BLH Series B-52 B-51

Brushless DC Motors Intro duction BLF BLU BLH Installation. Brushless DC Motors. DC Input. AC Input DC Input. BLH Series. Page. BLH Series B-52 B-51 DC Input BLH Series Brushless DC Motors Intro duction BLF BLU BLH Installation C Input DC Input Page BLH Series B-52 B-51 RoHS-Compliant Brushless DC Motor and Package BLH Series The BLH Series combines

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

Electronic Pressure Switch EDS 300

Electronic Pressure Switch EDS 300 Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5

More information

industrial drive systems PM LINE Permanent magnet single-surface brake 86 611..H00 86 621..H00

industrial drive systems PM LINE Permanent magnet single-surface brake 86 611..H00 86 621..H00 industrial drive systems PM LINE Permanent magnet single-surface brake 86 611..H00 86 621..H00 PM LINE Kendrion (Aerzen) GmbH, Germany Kendrion (Villingen) GmbH, Germany Kendrion Magnetic (Suzhou) Co.

More information

Encoders. the incremental encoders format such as relective optical technology, transmissive optical technology

Encoders. the incremental encoders format such as relective optical technology, transmissive optical technology the incremental encoders format such as relective optical technology, transmissive optical technology back devices, brakes and gearboxes at no extra cost to you. USA: +1 267 933 2105 Europe: +33 20928751

More information

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals

More information

PLUTO Safety-PLC. Manual Absolute Encoders

PLUTO Safety-PLC. Manual Absolute Encoders PLUTO Safety-PLC Manual Absolute Encoders English v6a 2TLC172006M0206_A Table of contents: 1 General... 3 1.1 Reaction time... 3 1.2 Safety parameters... 3 2 Electrical... 4 2.1 Separation with Gateway

More information

Servo Info and Centering

Servo Info and Centering Info and Centering A servo is a mechanical motorized device that can be instructed to move the output shaft attached to a servo wheel or arm to a specified position. Inside the servo box is a DC motor

More information

Absolute Rotary Encoder E6CP

Absolute Rotary Encoder E6CP Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the

More information

ISO 15407-1/2 (VDMA 24563) ISO 02 (18 mm) - ISO 01 (26 mm) Valves

ISO 15407-1/2 (VDMA 24563) ISO 02 (18 mm) - ISO 01 (26 mm) Valves BD ISO 0/ (VDM ) ISO 0 ( mm) ISO 0 ( mm) Valves BDE = solenoid valves ISO 0/ with integrated connection including V DC coils and connector BDB = solenoid valves ISO 0/ with external connection with M connector

More information

Specifications for Volkswagen Industrial Engine

Specifications for Volkswagen Industrial Engine Volkswagen 1 industrial engine Specifications for Volkswagen Industrial Engine AFD 1.9 ltr. TDI diesel engine EURO 2 Volkswagen AG, Wolfsburg Volkswagen AG reserves the right to introduce amendments or

More information