ELECTRONIC BOARDS - SUPRA



Similar documents
OPL BASIC. Dosing System for Professional Laundry machines. Contents

Bluetooth HC-06 with serial port module Easy guide

What is a multimeter?

EDI Distributor Control Interface Wiring and Setup Instructions

GAE953 Electrical Alarm Unit 19" with Indicator

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

LIFT CONTROL SYSTEMS CATALOGUE 2007

Telefon (+45) Telefax (+45) Installation and operating manual

Quick Connect. quick - simple - efficient.

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

Model SETR-50 and SETR-51 Trim Tab Control

Inwall 4 Input / 4 Output Module

M1000 Process Alarm Monitor

NC-12 Modbus Application

LIFT CONTROL SYSTEMS CATALOGUE 2007

SECTION 7 - REPAIR/REPLACEMENT PROCEDURES

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Mini Breakout-Board. CNC Interface for LPT Port. Installation Manual Version 4

LDG DTS-4/4R Desktop Coaxial Switch / Remote

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Contractors Guide Central Inverter System Installation

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

Inverter / Charger Installation General Operations and AC and DC Connections

DC LOAD TESTING Gian Trento June 18 th, 2004

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Air conditioning, electrical testing

Technical Information POWER PLANT CONTROLLER

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Heating Controller. Building Technologies HVAC Products

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

GROUND DETECTION CIRCUITS FOR STATIONARY APPLICATIONS (IN PLAIN DOWN TO EARTH LANGUAGE)

R448 & R448 V50 A.V.R.

USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES

Argus Technologies Pathfinder10kW to Cordex3.6kW Shelf Replacement Procedure

Manual K 100 PR K 100 W PR. Measuring and control instruments for ph and ORP measurements ph 25.0 C S1 S2 Auto ph 25.

Subject: Circuit Board troubleshooting Bulletin

Option field bus: without bus with profibus DP. Design-Index (Subject to change)

Driver Pant 8 and antenna switcher Ant 8. User manual

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

SYSTEM 4C. C R H Electronics Design

Mini Effect Gizmo. User s Manual. RJM Music Technology, Inc.

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Streaming Potential System (SPT1000, SPD1000)

The Child Reminder System Installation Manual

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Current Loop Tuning Procedure. Servo Drive Current Loop Tuning Procedure (intended for Analog input PWM output servo drives) General Procedure AN-015

VX 2400 Dimmer User's Manual

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

TMS TANK MANAGEMENT SYSTEM

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

LOXONE 12 Channel Amplifier

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

IVIS IVIS - Indoor Video Insertion System

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

Electrical Systems - IQAN Digital Control System. IQAN Control System Components

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

Contact Center CC-165 INSTALLATION & USER'S GUIDE

3FBD DC Motor Drive User Manual

ABB PSPS Erich Steinmann; Generator control-2013

Current and voltage measuring relays

Service Information CALIBRATION PROCEDURE AND TROUBLESHOOTING FOR LINEAR GOVERNOR CONTROLLERS NOTE

ANTI-THEFT SYSTEM Volvo 850 DESCRIPTION & OPERATION BASIC ALARM ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems

Self Monitoring Power Supply (BPSM)

ECO Door Controller Installation Guide

Quick Start Guide for High Voltage Solar Inverter DC-AC Board EVM. Version 1.3

- Designed to meet with the environmental stresses of ships and heavy industry. SESOBS

WinLIN Setup and Operation:

R438 A.V.R. Installation and maintenance R 438. This manual is to be given to. the end user T10. Armature 6- Field X2 Z1 X1 Z2 E+ E- 0V

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

i ChatterBox! Motorcycle Security

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Inwall Room Temperature Unit

USER MANUAL Online UPS 6K/10K RACK

GSMPBX version 1.3 Datasheet

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

PC Software for VAV compact and modular controllers

The modular concept of the MPA-3 system is designed to enable easy accommodation to a huge variety of experimental requirements.

MANUAL PC1000R

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Art.275 PABX Interface

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

Troubleshooting and Diagnostics

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Instruction book IQAN-MDM. Publ. no. HY /UK Edition June, 2007

To Purchase This Item, Visit BMI Gaming Operation Manual

APPLICATION NOTE USING A MODEL 3060-MS SERIES AS A REGENERATIVE AC SOURCE FOR PV INVERTER TEST APPLICATIONS. Abstract.

ECM Diagnosis. Section 11. Learning Objectives:

User Manual of Grid Tie Inverter with Limiter

Fitting/Installation Guide - UNIVERSAL

POWER WAVE 455M/STT & (CE)

ELAN AUDIO. Operational Description. News Work Station NWS-01

Transcription:

ELECTRONIC BOARDS - SUPRA

INDEX TROUBLESHOOTING BOARD SOURCE INTERCONNECTION C.E. INTERFACE PH INTERFACE HARD SWITCH RELAYS 32-OUTPUT CARD BOARD # 7520

# TROUBLESHOOTING BOARD 12V CONNECTIONS: CONNECTOR 1:

Terminals are top-down numerated: 1. Common terminal of the transformer 2. Live terminal of the transformer 3. Fuse output from electrovalves 4. 0V source terminal 5. 0V outputs to commutators 6 and 7. Power stage: Transformer ground (/common?); any of both terminals 8 and 9. Power stage: towards fuse input of electrovalves; any of both terminals. The squares mean that the terminals are jumpered. CONNECTOR 2: Terminals are left-to-right numbered: 1. +24V Source 2. 2, 3, 4, 5, 6 and 7 as shown below 8. CTF

8. CTF POTENTIOMETER: MIN MAX DESCRIPTION: This card is used for detecting and signalising the troubles arising from maximum pressure, minimum pressure and electrovalve fuses. It should actuate regardless the irrigation system is started up manually (through the commutators) or by the irrigation controller. It features just one (/timing?) adjustment potentiometer to temporize the minimum pressure connection. This time ranges between 2-3 secs up to 5 minutes, approximately. By turning the potentiometer clockwise, the time increases; counterclockwise, it decreases. Whenever any trouble arises, the three relays GET FIXED (are powered down/go off?/get deactivated? are set-off??), and both the led and controller alarms get signalled (/activated??). To re-arm (/re-activate/ re-energize), press the rest button located on the cabinet door. TROUBLESHOOTING: The troubles that may arise in this board most typically are: Some detection is not operating. The proof for this is to check each alarm, one at a time.

The relays remain permanently activated. In such a case, the card should be replaced for a new one. As an emergency measure, the side connector could be disconnected, in order to power the card off and, consequently, to allow operation without any alarm.

SOURCE CARD DESCRIPTION: This card is fed 24V AC from the transformer, releasing in turn +5V DC to feed all the framework electronics, and +24V DC to feed the relay cards and the cabinet door LEDs. It is protected by an input fuse whose rating varies between 2 and 4 Amps, according to the number of outputs to be operated.

2 4 Amp Fuse MAINTENANCE: The first thing to check is the fuse; then, with a polymeter (/multimeter??), check the 24V AC input and both the +5V DC and +24 V DC outputs. If the output reading is over 12V, try to calibrate with a multi-turn potentiometer.

#INTERCONNECTION BOARD DESCRIPTION: This card, as stated by its name, is used to link the door terminals with the back panel of the cabinet. It converts the 40-way ribbon cable into screw-type terminals. The dot on the board indicates the side where to place the different-colour wire in the ribbon cable. TROUBLESHOOTING: This card has no active component. The only trouble it may experience would be a burned track or a failed welding between the screw (/bolt?) connector and the ribbon cable. # INTERCONNECTION BOARD

# C.E. INTERFACE CARD # C.E.INTERFACE CARD

DESCRIPTION: The connections to this card should be done as depicted in the figure above. This card amplifies the electrical conductivity signals, producing a voltage level corresponding to half the conductivity readings. Thus, a 1V voltage level would mean a 2 mili-siemens conductivity value. Conductivity adjustments and settings are carried out through the P1 and P2 potentiometers, for probes #1 and #2, respectively. Potentiometers P3 and P4 are used to adjust and to set the 0V level when the probes are not connected, but normally- they should not be re-adjusted. MAINTENANCE: The first thing to do is to check the fuse with a multimeter because, although the external appearance of the fuse might be good, it may be internally broken. In case of having a strong deviation between the card reading ant the real one measured with a standard conductance meter (/conductivity standard?), re-calibrate P1 and/or P2 in order to readjust the values.

#ph INTERFACE CARD # ph INTERFACE CARD

DESCRIPTION: With this card, the ph probe signals are amplified and converted into a voltage ranging between 0V and 5V DC. When the probes are in a ph 7 tampon solution, the voltage should be about 2.5 V. When they are in a ph 4 tampon solution, it should settle about 1 V. Higher voltage readings would indicate a probe breakdown or malfunctioning. With the potentiometers, the output voltages can be re-adjusted (calibrated?). Perform this operation using only brand-new probes; else, the card response may be distorted. MAINTENANCE: Make sure the card is powered with 24 V AC. Check, by using brand-new probes, which the voltage readings for ph 7 and ph 4 are within the above cited ranges. Calibrate with the potentiometers, if necessary.

# HARD SWITCH External Hard Switch DESCRIPTION: This card protects our software. If this device is not available in the PC, no window will appear on the screen to indicate the protection switch is not available. # HARD SWITCH

MAINTENANCE: In case the card is not detected, verify that there is no problem either in the parallel port or in the software. There should not be any RUN TIME FILE (just on WINDOWS). If there is some, replace the card.

#RELAYS CARD DESCRIPTION: This card features only the relays, the protection diodes, signalising diodes and 60 V varistors in parallel with the contacts. Each relay has two terminals that correspond to each contact. This allows for using different voltage levels on each relay. However, we recommend not to use voltage levels above 24 V AC (do not go over 60 V without previously changing the varistors for another of appropriate rating for this new voltage level), in order to avoid the electric noise arsing from relay commutation. # RELAYS CARD

MAINTENANCE : In case of a failure, the first thing to do is to check the diodes, because they are the most sensitive part. Set the multimeter in the checking mode for diodes, and test their state. In order to check relay contacts and tracks, energize the relay and verify the continuity with the multimeter. First, the cables should be disconnected from their terminals. Check visually the condition of the tracks on the backside of the board.

#32-OUTPUT CARD # 32-OUTPUT CARD

DESCRIPTION: This card is a data-acquisition device via series port. It is capable of obtaining 8 Analog inputs and 8 digital inputs, as well as of activating 32 relays. The communication system is based on the RS485 Standard. The Analog inputs may work in two ways: 0-10 V (jumper off) or 4-20 ma (jumper on). The digital inputs can work with 12 V or 254V (do not connect inputs to different voltages; all of them must be at the same voltage level). They can also work with positive or negative common terminal, although habitually- we use the negative common terminal. There are available independent (/power?) feeding inputs for both the relays and the electronics. For this latter one, it is supplied by means of a toroidal transformer; although, at times, it has beed fed by a commuted source. The board has a dip-switch that is used to tell the card its number. This number is given in binary code; therefore, in order to know the card number, a summation of the weight of each switch (/breaker?) has to be carried out, according to the following table. SWITCH (/breaker?) WEIGHT 1 1 2 2 3 4 4 8 5 16 6 32 7 DO NOT TOUCH 8 ON= 19200 OFF=9600 MAINTENANCE: In case of trouble, check the feeding connections and verify that the voltage levels at all points are the correct ones. There are three LEDs available that indicate: *1ª._ *2ª._ Source Reception OD a command through the series port. (When receiving a communication, it does a fast flickering; when there is no communication, the flickering is slow and with a steady pace).

*3ª._ Watchdog, both for communication and for hardware. There exists a jumper in front of the microprocessor that should be located towards the board edge. Along with the communication connector, there is another jumper that allows shutting off the communication bus (See the electrical characteristics of the RS485 Standard)

MODULE 7520 DESCRIPTION: This board is Rs232-to-Rs485 converter. It allows changing the signals between the PC and our system. TROUBLESHOOTING: The device has a LED that indicates its state; it should be flickering fast (a flickering for each command). If this LED is off, check that the source feed is the correct one; or if there is a short-circuit in the bus. If the LED is on steadily, there is a problem in the communication, either between the module and the PC, or between the module and the electronics.