1 PSC European Refrigeration Controls Catalogue Catalog Section 9 Product Bulletin PD-GAS-E Refrigerant Leak Detecting System Introduction This range of refrigerant leak detecting systems is designed for permanent installation. They monitor refrigerant leakage on a continuous basis. It provides a valuable warning before refrigerant leaks impair system efficiency and running costs and, over time, prevents major refrigerant loss. Refrigerant wastage and replenishment are both economical and environmentally unacceptable. The refrigerant leak detecting system consists of: A refrigerant detector. This detector senses refrigerant leakage and can be used as a stand-alone device or can be connected to a monitoring unit. Various detectors for different refrigerants are available. Refrigerant Leak Detecting System A monitoring unit. The monitoring unit shows the status of one or more remote detectors. A wall mount or a DIN rail mount model is available. Feature and Benefits! Two alarm thresholds Pre-alarm signalling before an alarm is activated! No on-site calibration necessary Easy installation.! Semi-conductive sensing element Long lifetime and long-time stability! Alarm memory on detector Possibility to memorise too high refrigerant concentration! Selectable auto reset or Auto reset or manual reset is field selectable manual reset mode on monitoring unit! Up to 10 detectors can be connected to one monitoring unit Multiple detectors can be monitored by one unit. Makes future expansion very easy Johnson Controls Inc. Catalogue Section 9

2 2 Leak Detecting System Refrigerant detector Description Each detector can work as a stand-alone unit, or can be connected to a monitoring unit for remote monitoring. (See page 4 and 5) The detector has 2 relay outputs. The prealarm relay contact is closed when the refrigerant concentration exceeds the prealarm level, giving a pre-alarm signalling. When the concentration exceeds the alarm level, the alarm relay is activated. LED s indicate the status of the detector, such as: Power-on, Detector active, Alarm, and Alarm memory. Each detector is refrigerant specific. (See selection table on next page and the application table on page 9). Three different detector enclosures are available: Room version (GD2.0 type); Splashproof version (GS2.0 type) and Safety valve version (GR2.0 type). The detectors are delivered for a specific refrigerant. Field calibrations are normally not necessary. (See factory adjusted detection levels at page 9). Functioning (See layout drawing and drawing relay functioning ) If the power supply is switched on the green LED will light up to indicate power on. After 4 minutes a yellow LED will light to indicate detector active. The detector is now ready to sense refrigerant leakage. If the detected concentration of refrigerant, exceeds the pre-alarm level, the pre-alarm relay is activated (terminals 5 and 6) and the LED Alarm is lighted up. If the refrigerant concentration increases further and exceeds the alarm level, than the alarm relay is activated (terminals 7 and 8). If the concentration decreases, the relays will switch off, first the alarm relay, then the prealarm relay. The pre-alarm or alarm condition will be memorised by LED Alarm memory. This LED can be reset by pressing the reset button under the cover. Note: It is only possible to reset the alarm memory if the refrigerant concentration is below the pre-alarm level. Skip the alarm memory function by removing Jumper BY2. Fig. 1 Detectors GS2.0/GD2.0/GR2.0! Note The detector has a limited range to detect different types of refrigerants. It is important to check the presence of other gases that may cause an alarm. Such as: Gasoline, cigarette smoke, liquid cleanings, solvents, hydrogen from loading batteries, etc. It is recommended to test the system twice a year. See page 8 for check and calibration instructions.! Note The relay contacts should be powered by max. 24 V ac/dc. Fig. 2 Relay Function Catalogue Section Johnson Controls Inc.

3 Leak Detecting System 3 Layout Fig. 3 Wiring Diagram Fig. 4 Selection table Item code Refrigerant Enclosure type GD2.0-CFC CFC/HCFC universal Room, fig 12a GD2.0-HFC HFC universal Room, fig 12a GD2.0-NH3 Ammonia Room, fig 12a GS2.0-CFC CFC/HCFC universal Splash proof, fig 12b GS2.0-HFC HFC universal Splash proof, fig 12b GS2.0-NH3 Ammonia Splash proof, fig 12b GR2.0-CFC CFC/HCFC universal Safety valves, fig 12c GR2.0-HFC HFC universal Safety valves, fig 12c GR2.0-NH3 Ammonia Safety valves, fig 12c Note: See application table on page 9 and dimension drawings on page 10, Johnson Controls Inc. Catalogue Section 9

4 4 Leak Detecting System Monitoring units Description The Monitoring unit shows the status of one or more refrigerant detectors (See page 3 and 4). When the refrigerant concentration as measured by the detector exceeds the prealarm level, the Pre-alarm relay on the unit is activated, giving a pre-alarm. When the measured concentration exceeds the alarm level, the Alarm relay on the unit is activated. The Fault relay is energised when there is a detector or power supply failure. LED s indicate the status of the unit, such as: Power-on, Detector active, Pre-alarm, Alarm, and Fault. Two models are available, a 35 mm DIN rail version (G27C) and a wall mount version (G230C). Fig. 5 Monitoring Units, G27C/G230C Functioning If the power supply is switched on the green LED will light up to indicate power on. After 4 minutes a yellow LED will light up to indicate the unit is active. The unit is ready now to monitor the refrigerant detector(s). If the concentration of refrigerant, measured by the detector, exceeds the pre-alarm level, the pre-alarm relay is activated and the LED Pre-alarm is lighted up. If the refrigerant concentration increases further and exceeds the Alarm level, than the Alarm relay is activated. When the refrigeration concentration decreases the relays can be reset by pushing the Reset button in front of the cover. Note: It is only possible to reset the relays when the refrigerant concentration is low enough. Both models have the possibility to set the operation mode from manual to automatic reset. Model G230C has an additional buzzer build in which gives an audible alarm. This buzzer is automatic reset when the refrigerant concentration decreases. The proper functioning can be verified by pushing the test button. Note When monitoring more than 1 detector, the position of jumper BY1, on the detector, should be taken into account. This jumper should be removed for all detectors except the last one. (See also wiring examples on page 6) Fig. 6 Relay function Catalogue Section Johnson Controls Inc.

5 Leak Detecting System 5 Fig. 7 Wiring G27C Fig. 8 Wiring G230C Selection table Item code G27C G230C Enclosure type DIN Rail Mount Wall mount 1997 Johnson Controls Inc. Catalogue Section 9

6 6 Leak detecting system Wiring and mounting information. Detector location Correct placing of the detector is very important. The detector has to be mounted high (under the ceiling, not in the ceiling) for refrigerants lighter than air (Ammonia), and low (20 cm above the floor) for refrigerants heavier than air (CFC, HCFC, HFC). The detector must be mounted at a location where air streams cannot influence the detector.! Warning When wiring or servicing make sure that power supply is switched off. Fig. 9 Catalogue Section Johnson Controls Inc.

7 Leak Detecting System 7 Feature list Detector Monitoring unit GD/GS/GR2.0 G27C G230C Enclosure Wall mount DIN rail mount Power supply 230Vac 12Vdc 12Vac LED indication Power on Device Active Pre-alarm Alarm Fault Alarm memory Output relays Selectable auto reset/ man reset mode Build in Buzzer Alarm test Test Connector Pre-alarm Alarm Fault 24V 24V 24V 24V 24V 230V 230V 230V Optional accessories Item code SA 100 Description Service adapter 1997 Johnson Controls Inc. Catalogue Section 9

8 8 Leak detecting system Check and Calibration of refrigerant detectors To check and calibrate the detector you need a SA 100 service adapter, connected to a multimeter. Working of the detector. The GV value is a voltage proportional to the measured refrigerant concentration. This GVvoltage will increase with an increase in refrigerant concentration. The offset value (no refrigerant measured) need to be checked twice a year. The pre-alarm level and alarm level are set at a particular GV-voltage. A (pre-)alarm signal is activated when the GV-voltage exceeds the (pre-)alarm level.! Note In some cases the detector can give an alarm at start up of the system. This is no fault, it indicates that the detector has to be on for some minutes to stabilise after storing and transportation. The alarm will go off after a couple of minutes. Check and calibrating instructions The first action is to check the power supply to the detector at terminal 1 and 2. This should be 12V ac/dc ±15%. Connect the SA 100 service adapter to the test terminal and do the check /calibration as mentioned in the table bellow. Connect a multimeter to the service module and set the selector to the DC range Fig. 11. Fig. 10 Selector position Correct value Corrective action if value is not correct 5V DC 5V ± 0,15V Replace detector if value is not correct Offset GV-value See table page 9 Adjust the GV offset value using the GV potentiometer. Important: The detector has to be powered for at least 1 hour before checking. Avoid any airflow influence during the test. Zero setting of the GV offset value has to be done in clean air! Alarm level See table page 9 Adjust the Alarm level using the Alarm pot meter. Pre-alarm level See table page 9 Adjust the Pre-alarm level using the pre-alarm pot meter Note: The pre-alarm level is set at a percentage of the Alarm level. When the alarm level is re-adjusted than the Pre-alarm level will follow automatically. Catalogue Section Johnson Controls Inc.

9 Leak Detecting System 9 Trouble shooting Use the SA 100 service adapter, connected to a multimeter Problem Check point Remark Detector gives no alarm at gas influence Constant alarm from detector Constant alarm on monitoring unit Check that the GV-value will increase at gas influence Check the GV-value offset (See calibration instructions) Check that no other gases can cause a false alarm Check for EMC problems. Check if Jumper BY1 is mounted at last detector Check voltage on each detector (between terminal 3 and 4) When voltage is higher than alarm levels the alarm relays should be activated If GV value is higher than alarm level, move the detector to another area with clean air and calibrate If all BY1 jumpers are mounted, a wrong signal is sent to the monitoring unit If detector cable is close to high voltage wiring, electromagnetic induction can affect the detector signal Refrigerant application table and alarm levels Sensor type Refrigerant Pre-Alarm level Alarm level Offset GV Location Gx2.0- CFC CFC s, e.g.: R11, R12, R13, R113, R114, R500, R502, R503 HCFC s, e.g.: R22, R123, R124, R142, R401A/B, R402A/B, R403A/B, R408A, R409A ppm depending on gastype GV = 1,0V ppm depending on gastype GV = 1,0V ppm depending on gastype GV = 1,4V ppm depending on gastype GV = 1,4V 0,35V 0,35V Low Low Gx2.0- HFC HFC s, e.g.: R23, R32, R125, R134, R134a, R143a, R152a, R404A, R407A/B/C, R410A, R ppm depending on gastype GV = 1,0V Gx2.0- NH3 Ammonia, R ppm GV = 2,5V ppm depending on gastype GV = 1,5V 300 ppm GV = 3,5V 0,3V Low 0,2V High Note: The indicated values are typical for ambient temperatures at +20 C. To have an exact value you need to use calibration gas and calibrate at 20 C Johnson Controls Inc. Catalogue Section 9

10 10 Leak detecting system Dimensions (mm) Fig. 12a GD2.0 Detector Fig. 12b GS2.0 Detector Fig. 12c GR2.0 Detector Fig. 12d Mounting dimensions A. Connector CFC/HCFC/HFC: Male 1/2 Flare NH3: Male R1/2 Catalogue Section Johnson Controls Inc.

11 Leak Detecting System 11 Dimensions (mm) Fig. 13 G27C Monitoring Unit Fig. 14 G230C Monitoring Unit 1997 Johnson Controls Inc. Catalogue Section 9

12 12 Leak detecting system Power supply G230 G27C GD/GS/GR2.0 Frequency 50/60 Hz Power consumption GD/GS/GR 2.0 G27C G230 Ambient operating conditions Storage temperature Operating (storage) humidity Detector cable G230C/G27C GR2.0 GD/GS2.0 S pecifications 230Vac/12Vdc +10%/-15% 12Vac/dc ± 15% 12Vac/dc ± 15% 3W 2W 12W 0 to +50 C 0 to +50 C -20 to +50 C -40 to +70 C 10 to 90%RH (non condensing) 4 x 0,75mm 2, Max. 50 m, Screened cable 4 x 1,5mm 2, Max. 150m, Screened cable Terminals Screw type max. wire thickness 2,5 mm 2 Dimensions See drawings on page 10,11 Relay ratings GD/GR/GS G27C G230C Pre-Alarm relay SPST: 24Vac/dc, 1A SPST: 24Vac/dc, 1A Alarm relay SPST: SPST: 24Vac/dc, 1A 24Vac/dc, 1A Fault relay SPST: 24Vac/dc, 1A Directives Low voltage: 73/23/EEC EMC: 89/336/EEC Accuracy ± 15% of adjusted (pre-) alarm level. See page 9 Alarm level See application table at page 9 for factory setting Pre-alarm level See application table at page 9 for factory setting Material G27C G230C GD2.0/GS 2.0 GR2.0 Protection class Weight (g) Max number of connected detectors G27C G230C GD2.0 GS/GR 2.0 G27C G230C GD2.0 GS2.0 GR2.0 SA SPDT: 230Vac, 2 (0,5)A SPDT: 230Vac, 2 (0,5)A SPDT: 230Vac, 2 (0,5)A ABS/PC mixture Polycarbonate Polycarbonate PC, Brass (CFC,HCFC,HFC models)/ Steel (NH3 models). IP 30 IP 65 IP 21 IP The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office or representative. Johnson Controls shall not be liable for damages resulting from misapplication or misuse of its products. Johnson Controls International, Inc. Headquarters: Milwaukee, WI, USA European Headquarters: Westendhof 8, Essen, Germany European Factories: Lomagna (Italy), Leeuwarden (The Netherlands) and Essen (Germany) Branch Offices: Principal European Cities. This document is subject to change Printed in Europe Catalogue Section Johnson Controls Inc.

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors European Refrigeration Controls Catalogue Catalogue Section 4 Product Bulletin P215PR/RM Issue 01/03/2013 Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for

More information

WD-AMX Water Detection Controllers

WD-AMX Water Detection Controllers Page 1 of 5 WD-AMX Water Detection Controllers Features: Benefit: LED Status of leak status VFC output Audible alarm Auto or manual reset alarm output Uses an isolated AC signal which prevents oxidation

More information

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 DESCRIPTION CO transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air

More information

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed. FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

Dual Pressure Controls for Refrigeration, Air-conditioning and Heatpump Applications

Dual Pressure Controls for Refrigeration, Air-conditioning and Heatpump Applications Series P78 ual Pressure Controls for Refrigeration, Air-conditioning and Heatpump Applications Product Bulletin These dual pressure controls are designed for use in a variety of applications involving

More information

Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains

Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Drayton Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Invensys Controls Europe Technical Helpline: +44 (0) 845 130 7722 www.draytoncontrols.co.uk Installation

More information

www.sebury.com.cn Digital Keypad Use s Manual

www.sebury.com.cn Digital Keypad Use s Manual K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4

More information

Drayton Digistat +2RF/+3RF

Drayton Digistat +2RF/+3RF /+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer

More information

ACS-30-EU-EMDR-10-MOD

ACS-30-EU-EMDR-10-MOD Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature

More information

Y7230A CO 2 Alarm System

Y7230A CO 2 Alarm System Y7230A CO 2 Alarm System FOR CO 2 GAS DETECTION PRODUCT DATA FEATURES APPLICATION Y7230A CO 2 alarm system is used to detect gas leaking from CO 2 beverage dispensing systems and posts an alarm to occupants

More information

EzFlex Combustible Gas Leak Detector Model EZ40

EzFlex Combustible Gas Leak Detector Model EZ40 User's Guide EzFlex Combustible Gas Leak Detector Model EZ40 Introduction Congratulations on your purchase of the Extech EZ40 Combustible Gas Leak Detector. The EZ40 detects the presence of combustible

More information

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese.

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese. Page 1 of 6 Application Proportional 0-10V or 3-position modulating or On/ Off control of Frese OPTIMA Compact valves in heating, ventilating and air conditioning systems. The actuator can be mounted on

More information

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS FRANCE Head office USA 4 Rue du Bois Chêne le loup Parc d Activité de Brabois 54 500 VANDOEUVRE LES NANCY (33) 0383442413, Fax (33) 0383443797

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05 RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,

More information

SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P

SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P 2 Alarm Levels Bargraph + LED Indication of Gas Concentration Visual and Audible Signalization of Activated Alarm Levels 2 SPDT 5A/250V Output Relays Shock-Proof

More information

Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN

Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN Power Supply and Indicator Unit Type 5024-1 Fig. 1 Type 5024-1 Mounting and Operating Instructions EB 9539 EN Edition October 2003 Application 1 Application The Type 5024-1 Power Supply and Indicator Unit

More information

GSM HOME SECURITY SYSTEM

GSM HOME SECURITY SYSTEM Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : GSM-120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5.

More information

Water Leak Detection System

Water Leak Detection System Water Leak Detection System Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email:info@rodisystems.com 936 Highway 516 Aztec, NM 87410-2828 Manual Revisions and Copyright

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

TMS TANK MANAGEMENT SYSTEM

TMS TANK MANAGEMENT SYSTEM TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS

More information

Water Leak Detector BA/LDT Accessories Termination and Troubleshooting

Water Leak Detector BA/LDT Accessories Termination and Troubleshooting Overview & Identification The is designed to sense the presence of water and alert a central monitoring system of the potentially destructive situation. Upon water detection, an alarm relay changes state,

More information

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation

More information

FX07 Field Controller

FX07 Field Controller Product Bulletin FX07 Field Controller Issue Date March 25, 2008 FX07 Field Controller The FX07 is a high performance field controller designed specifically for commercial Heating, Ventilating, Air Conditioning,

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

600-GD & 600-GDL 600 SERIES GAS DETECTOR

600-GD & 600-GDL 600 SERIES GAS DETECTOR 600-GD & 600-GDL 600 SERIES GAS DETECTOR INSTALLATION AND OPERATING INSTRUCTIONS This page has been deliberately left blank. Page 1 Table of Contents 1 WARRANTY...3 2 IMPORTANT...3 3 CAUTIONS WHEN USING

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC HOJA TÉCNICA 1400H101 Edición 01 (02 de 08) www.ako.es GENERAL TECHNICAL SPECIFICATIONS Temperature range: -50ºC to +99ºC type: NTC Total accuracy ( + controller): ±1ºC lead extension with cable AKO-15586:

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

G670 Intermittent Pilot Ignition Controls

G670 Intermittent Pilot Ignition Controls Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin Issue Date 0300 Intermittent Pilot Ignition Controls Figure 1: Intermittent Pilot Ignition Control

More information

Model: DC-A2IO Advanced HVAC Controller

Model: DC-A2IO Advanced HVAC Controller Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

Model SRMD Setra Remote Monitoring Display

Model SRMD Setra Remote Monitoring Display Model SRMD Setra Remote Monitoring Display 1.0 GENERAL INFORMATION Thank you for purchasing the Setra Remote Monitoring Display (SRMD). The SRMD is a digital panel meter with a bright 1 LED display for

More information

- Designed to meet with the environmental stresses of ships and heavy industry. SESOBS 98-5013

- Designed to meet with the environmental stresses of ships and heavy industry. SESOBS 98-5013 Sid/Page 1 SESOBS THE SMOKE DENSITY MONITOR - Easy and safe to operate and install - Complete with sealing air fans. - Remote smoke density indication possible. - Designed to meet with the environmental

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate 1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration

More information

T5000 T000 LCD Digital Fan Coil Thermostat

T5000 T000 LCD Digital Fan Coil Thermostat T5000 T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostats are designed to control heating, cooling, or year round air conditioning unit in Commercial,

More information

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems TDB301021en/06.2013 LIETRAXX -A etwork and system protection (S protection) for monitoring

More information

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors www.static-control.in 1 Introduction The detection or monitoring of flue gases and or hazardous gases has been a complex subject

More information

IO-DIM6 6-Channel, Digital to Analogue Converters

IO-DIM6 6-Channel, Digital to Analogue Converters Page 1 of 6 IO-DIM6 6-Channel, Digital to Analogue Converters Features: Benefits: Input status indication Calibrated output DIN Rail mounting Expands controller input capacity Fault finding LED indication

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

FX07 Field Controller

FX07 Field Controller Product Bulletin FX07 Field Controller Issue Date May 5, 2011 FX07 Field Controller The FX07 is a high performance field controller designed specifically for commercial Heating, Ventilating, Air Conditioning,

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases

More information

P70, P72, and P170 Series Controls for Dual Pressure Applications

P70, P72, and P170 Series Controls for Dual Pressure Applications P70, P72, and P170 Series Controls for Dual Pressure Applications Product Bulletin Code No. LIT-125455 Issued August 30, 2012 Supersedes September 1, 2000 The P70, P72, and P170 controls for dual pressure

More information

CO2 Alarm. Operation. Application

CO2 Alarm. Operation. Application CO Alarm 100-77V AC Supply Voltage Two pre-configured alarm and control thresholds Thresholds factory set to customer requirements on dispersive infrared sensing technology Optional internal audible alarm

More information

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter www.kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter Description The KVO Vortex flow meters utilize two primary sensing elements a vortex shedding

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 mail@uni-valve.com www.uni-valve.com. Installation and operating manual

Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 mail@uni-valve.com www.uni-valve.com. Installation and operating manual Uni-Valve A /S VENTILER & INSTRUMENTER Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 mail@uni-valve.com www.uni-valve.com UNI-EL Electric actuator Installation and operating manual Remote position

More information

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual CMR Electrical Ltd Bolton House Five Chimneys Lane Hadlow Down East Sussex TN22 4DX Tel: 01825 733600 LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual Contents 1) Operation 2)

More information

PSTN Home Alarm System

PSTN Home Alarm System PSTN Home Alarm System User Manual Model: PST-TEL99E Please read this user guide carefully before operation and installation. Contents 1. Product Overview... - 3-2. Main Function & Features... - 3-3. For

More information

Heating Controller. Building Technologies HVAC Products

Heating Controller. Building Technologies HVAC Products 2 474 Heating Controller RVP300 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones with or

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

T7560A,B,C Digital Wall Module

T7560A,B,C Digital Wall Module T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

A.1. a Division of Pittway Corporation. Documento: M-010.1-MGAS-ENG. Edizione: 01/1997 Rev.:

A.1. a Division of Pittway Corporation. Documento: M-010.1-MGAS-ENG. Edizione: 01/1997 Rev.: Documento: M-010.1-MGAS-ENG Edizione: 01/1997 Rev.: A.1 a Division of Pittway Corporation FRONT PANEL & VISUAL INDICATIONS GENERAL TROUBLE GENERAL PROGRAMMING IN PROGRESS ENABLE/ALARM/TROUBLE (ZONE 1 ALARM

More information

ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE

ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE Emergency Response System INSTALLATION & PROGRAMMING GUIDE Copyright micron 2005 Contents Product Description 3 Console Operation Overview 4 Console Wiring Diagram 5 User Manual 6 Transmitter Assembly

More information

BEP FD-2 CONTOUR MATRIX FUME DETECTOR

BEP FD-2 CONTOUR MATRIX FUME DETECTOR BEP FD-2 CONTOUR MATRIX FUME DETECTOR INSTALLATION AND OPERATING INSTRUCTIONS Table of Contents 1 WARRANTY...3 2 IMPORTANT...3 3 CAUTIONS WHEN USING GAS SENSORS...3 4 FEATURES...4 5 SPECIFICATION...4 6

More information

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual Doc.No. NDP 192U-02 Electric Pump Controller CE-124P Instruction Manual 1. Parts Name and Function 1) POWER LED Indicate that CE-124P is powered up. 2) START/STOP KEY (SELECTOR KEY) Used to start and stop

More information

WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING

WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING DESCRIPTION: An electronic control panel used in conjunction with one pulse meter (water meter with pulse output proportional to flow rate)

More information

I STAR COMPUTER CO., LTD

I STAR COMPUTER CO., LTD I STAR COMPUTER CO., LTD Mini Redundant Power Supply 300W+300W for IPC-Computer Model No. TC-300R8 Table of content 1. Introduction...1 2. Specification 2.1 Input Voltage...1 2.2 DC Output...1 2.3 PS-ON

More information

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual 5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...

More information

Ammonia Detection System Codes and Design Specifications

Ammonia Detection System Codes and Design Specifications Ammonia Detection System Codes and Design Specifications December 28, 2015 Revision 5 920 N Trade Winds Pkwy Columbia, MO 65201 Ammonia detection system codes and design specifications Following is a discussion

More information

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI) FLARE MONITORS Infrared Sensors for Monitoring Smokeless Flares, Pilots, and Flame Intensity FMDS2014 FLARE MONITOR (FM) Monitor smokeless flare combustion efficiency to maximize destruction of hazardous

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.

More information

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION The SST Model 5010 Two Channel Smoke/Fire Detection Module provides two independent detection input channels for the NOVA-5000

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765 IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration

More information

DUCT SMOKE DETECTOR D4120

DUCT SMOKE DETECTOR D4120 Purpose/Application National and local safety standards and codes recognize the ability of air duct systems to transfer smoke, toxic gases, and flame from area to area. Sometimes smoke can be of such quantity

More information

12 Series - Time switches 16 A. Features 12.01 12.11 12.31

12 Series - Time switches 16 A. Features 12.01 12.11 12.31 Mechanical time switches - daily time setting Type 12.01-1 Pole 16 A CO (SPDT) Type 12.11-1 Pole 16 A O (SPST-O) 17.6 mm width Type 12.31-0000 - 1 Pole 16 A CO (SPDT) Type 12.31-0007 - 1 Pole 16 A CO (SPDT)

More information

OPL BASIC. Dosing System for Professional Laundry machines. Contents

OPL BASIC. Dosing System for Professional Laundry machines. Contents OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page

More information

HomeSafe-Basic VT-PS99E. User s Manual. PSTN Home Alarm System. Page: 1 / 15

HomeSafe-Basic VT-PS99E. User s Manual. PSTN Home Alarm System. Page: 1 / 15 HomeSafe-Basic VT-PS99E User s Manual PSTN Home Alarm System Page: 1 / 15 Table of Contents 1. Product Overview:... 3 2. Main Functions & Features... 3 3. For Your Safety... 4 4. VT-PS99E Characteristics...

More information

How To Use A Flowmeter

How To Use A Flowmeter INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

MOUNTING AND OPERATING INSTRUCTIONS

MOUNTING AND OPERATING INSTRUCTIONS MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall

More information

Actuator for modulating control AME 435

Actuator for modulating control AME 435 Data sheet Actuator for modulating control AME 435 Description The actuator automatically adapts its stroke to the valve end positions which reduces commissioning time (self stroking). The advanced design

More information

AUTODIALLER / QUICKDIALLER - SA132

AUTODIALLER / QUICKDIALLER - SA132 AUTODIALLER / QUICKDIALLER - SA132 INSTRUCTION LEAFLET ENGLISH www.thermomax-group.com CONTENTS 1 SETUP AT A GLANCE... 2 2 FOREWORD....... 3 3 INSTALLATION...... 4 4 KEYPAD AND INDICATORS...... 5 SETTING

More information

ABLOY DA60 SWING DOOR OPERATOR Installation and commissioning manual Abloy Oy An ASSA ABLOY Group company APPROVALS / STANDARDS Low Voltage directive 7//EEC as amended by the directive 9/68/EEC EMC directive

More information

Chapter 9 N.C. C. N.O. Single-Pole Double-Throw

Chapter 9 N.C. C. N.O. Single-Pole Double-Throw rather than providing multiple choices. The sensor modules used may only be suitable for use with the matching controller so it is wise to read the specifications to make sure the unit suits your application.

More information

Fire Alarm Control Panel. Family. Operating Manual

Fire Alarm Control Panel. Family. Operating Manual Fire Alarm Control Panel Family Operating Manual CONTENTS System Description AH-03312 System Characteristics... Fire Signal Receiving Board Description-4L... Fire Signal Receiving Board Description-8L...

More information

Contents. Document information

Contents. Document information User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB

More information

AC-115 Compact Networked Single Door Controller. Installation and User Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.

More information

Stove Guard Kit User Manual

Stove Guard Kit User Manual Stove Guard Kit User Manual Innohome improves the Safety of your Home. inno home www.innohome.com Stove Guard Kit User Manual Stove Guard Kit User Manual Congratulations! You now own one of the most intelligent

More information

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

RVL470. Heating Controller. Building Technologies HVAC Products. Series B 2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones

More information

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor CruzPro VAF110 AC Volts, Amps, Frequency, kw Monitor Table of Contents Introduction............................ 3 Specifications........................... 4 Installation..............................5

More information

Remote Monitoring and REC 501 Control Unit Product Guide

Remote Monitoring and REC 501 Control Unit Product Guide Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the

More information

How To Use A Ds340 (Dsp)

How To Use A Ds340 (Dsp) Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions

More information

P66 Series Electronic Fan Speed Controls

P66 Series Electronic Fan Speed Controls P66 Series Electronic Fan Speed Controls Product Bulletin Code No. LIT-125465 Issued September 30, 2009 Supersedes March 23, 2006 The P66 Series Electronic Fan Speed Controls are refrigerant pressure actuated,

More information

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181 Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.

More information

Manual for Fire Suppression & Methane Detection System

Manual for Fire Suppression & Methane Detection System Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327

More information

DS 1.102 DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

DS 1.102 DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches DS 1.102 02/99 AIR ROOM TEMPERATURE SENSOR with fan speed control switches Specification No. 528-X-XXX* The Active Room Temperature sensor incorporating fan speed control switches is designed to give a

More information

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature

More information

Series 6000 Torque measured metal bellow coupling

Series 6000 Torque measured metal bellow coupling Properties Free of float metal bellow coupling with integrated torque measurement Non-contact measurement system, high robustness High torsional stiffness Limited torque of inertia Performance Measurement

More information

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:

More information

SMART SENSOR COLLECTION

SMART SENSOR COLLECTION TEMPERATURE SENSOR This sensor measures temperature in degrees Celsius or Fahrenheit. It works with all SensorHawk base units (SensorHawk-2, SensorHawk-8 and SensorHawk8/20) as well as the SecurityHawk-8

More information

Agilent 4338B Milliohm Meter

Agilent 4338B Milliohm Meter Agilent 4338B Milliohm Meter 10 µω to 100 kω Technical Overview Introduction Ideal for precise measurements of extremely low resistances using an ac test signal, the Agilent Technologies 4338B suits bench-top

More information

FIREDEX 2200. Conventional Fire Panels

FIREDEX 2200. Conventional Fire Panels 68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class

More information

ZC-24DO CANopen I/O Module: 24 Digital Outputs

ZC-24DO CANopen I/O Module: 24 Digital Outputs Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches

More information

FEMA ELECTRÓNICA. Serie ISC SIGNAL CONVERTERS WITH GALVANIC ISOLATION. MODEL ISC-IAC for AC Currents ISC-IDC for DC Currents USER S MANUAL

FEMA ELECTRÓNICA. Serie ISC SIGNAL CONVERTERS WITH GALVANIC ISOLATION. MODEL ISC-IAC for AC Currents ISC-IDC for DC Currents USER S MANUAL ISOLATED SIGNAL CONVERTER Serie ISC SIGNAL CONVERTERS WITH GALVANIC ISOLATION FEMA ELECTRÓNICA MODEL ISC-IAC for AC Currents ISC-IDC for DC Currents USER S MANUAL HT1501r150908 FEMA ELECTRÓNICA - Page

More information