1 Troubleshooting and Diagnostics The troubleshooting and diagnostics guide provides instructions to assist in tracking down the source of many basic controller installation problems. If there is a problem with a controller installation, please review these instructions and if a listed problem matches the controller s problem, review the possible causes and corrective actions. 1.0 Troubleshooting Some of the troubleshooting instructions require a digital voltmeter (DVM) to verify source voltages, circuit continuity, and noise levels on the EntraGuard Gold controller. Please have a DVM on hand before beginning troubleshooting. Refer to Figure 1 on this page and Figure 2 on page 2 to identify items on the controller PCBs. Reference Document Figure 1: The EntraGuard Gold Main Board Web: [email protected] Page 1 of 18
2 Reference Document Troubleshooting and Diagnostics Figure 2: The EntraGuard Gold Voice Channel and I/O Board Web: Page 2 of 18
3 Troubleshooting and Diagnostics Problem Possible Cause Corrective Action The Doors software cannot be installed on the host computer. The controller does not power-up (the LCD is blank and the keypad does not light up). 1. The host computer does not have a Pentium microprocessor. 2. The host computer does not have enough RAM memory. 3. The host computer does not have enough hard disk space. 4. The host computer s video card/monitor resolution is too low. 5. The host computer is running an operating system incompatible with the Doors software. 6. The host computer does not have a compatible operating system installed. 1. No power or insufficient power has been supplied to the system. Verify the host computer meets the minimum requirements specified in the Doors Users Guide (P/N ). Check the main power circuit breaker. Verify the positive power lead is on TB-2, pin 1 and the negative power lead is on TB-2, pin 2 (see Figure 2 on page 2). Measure the input voltage across pin 1 (positive) and pin 2 (negative) of TB- 2. The voltage should read between 12 and 14 VDC. Disconnect the power supply from the controller and verify the supply s voltage. The voltage should read between 12 and 14 VDC. Verify there is a proper earth ground. Reference Document Web: [email protected] Page 3 of 18
4 Reference Document Troubleshooting and Diagnostics Problem Possible Cause Corrective Action The controller cannot communicate with the Doors access control program. 1. Verify data is being transferred to and from the controller (see Corrective Action column). 2. The communication cable is loose or unplugged. 3. The JP3 INT_MODEM jumper is not set correctly. 4. The modem type in use is incompatible. 5. The controller to PC direct-connect cable is not wired correctly. On the right side of the controller s main board is a set of communication LEDs (see Figure 1 on page 1). Initiate a data transfer command and view the Tx+, Tx-, DTR, and CTS LEDs. These LEDs should flicker if data is being transferred to and from the controller. Verify the communication cable is plugged in correctly. Verify the JP3 INT_MODEM jumper (see Figure 1 on page 1) is set correctly for the chosen mode of communication. - If you are using the RJ11 phone port for communication, the jumper should be set ON JP3. - If you are using the RS-232 port for communication, the jumper should NOT be on JP3. Refer to the modem s manual and verify the modem is Hayes compatible, communicates at 9600 baud or greater, can be configured to turn error checking off, and has nonvolatile RAM backup. If the installation uses a Keri Systems cable, verify the correct cable has been installed. If the installation uses a self-made cable, refer to the instructions in the EntraGuard Gold Quick Start Guide (P/N ) and verify the cable has been wired correctly. Web: [email protected] Page 4 of 18
5 Troubleshooting and Diagnostics Problem Possible Cause Corrective Action 6. Doors is not configured to communicate through the proper COM port. 7. The communication cable is connected to the wrong COM port. 8. The communication cable is connected to the wrong controller. 9. The master controller is not an EntraGuard Gold controller. 10. The master controller is not set with address The Doors program is connected to the wrong site (if the software is configured for multisite mode). 12. The wrong PIN has been entered (if the software is configured to use the PIN security feature). 13. The controller s firmware and the Doors software are not compatible. 14. The host computer s serial port has an incompatible UART. Refer to the Doors Users Guide (P/N ) or online help for COM port configuration instructions. Run COMTEST to verify basic COM port operation. Verify the communication cable is connected to the correct COM port. Verify the communication cable is connected to the master controller in the access control network. Verify the master controller is an EntraGuard Gold (not a PXL). Verify the master controller s address is 1. In the Doors program, click on the Select Site button and verify the correct site has been selected. In the Doors program, verify the PIN is correct in the Setup > System > Sites menu option. The firmware found in older controllers is not compatible with Doors software. Contact your Keri Dealer to verify firmware/software compatibility. The serial port must have a UART. Consult a computer technician to resolve this problem. Reference Document Web: [email protected] Page 5 of 18
6 Reference Document Troubleshooting and Diagnostics Problem Possible Cause Corrective Action The EntraGuard s internal modem will not communicate. The controller will not communicate with the modem (if using an external modem). 15. There is an IRQ conflict. 16. The COM port is not working. 1. The JP3 INT_MODEM jumper is not set correctly. 1. Verify data is being transferred to and from the controller (see Corrective Action column). 2. The modem is turned off. 3. The modem was plugged into an already active controller. 4. The controller to modem cable is not correct. 5. The modem type in use is incompatible. Consult a computer technician to resolve this problem. Consult a computer technician to resolve this problem. Verify the JP3 INT_MODEM jumper (see Figure 1 on page 1) is set ON JP3 for use with the internal modem. On the right side of the controller s main board is a set of communication LEDs (see Figure 1 on page 1). Start a data transfer command and view the Tx+, Tx-, DTR, and CTS LEDs. These LEDs should flicker if data is being transferred to and from the controller. Verify the modem s power is on. Turn the power off to both the controller and modem. Power the modem on and then the controller. If the installation uses a Keri Systems cable, verify the correct cable has been installed. If the installation uses a self-made cable, refer to the instructions provided in the EntraGuard Gold Quick Start Guide (P/N ) to verify the cable has been wired correctly. Refer to the modem s manual and verify the modem is Hayes compatible, communicates at 9600 baud or greater, can be configured to turn error checking off, and has nonvolatile RAM backup. Web: [email protected] Page 6 of 18
7 Troubleshooting and Diagnostics Problem Possible Cause Corrective Action The host PC will not communicate with the modem. 6. The modem cable is connected to the wrong controller. 7. The JP3 INT_MODEM jumper is not set correctly. 8. The master controller is not an EntraGuard Gold controller. 9. The master controller is not set with address The Doors program is connected to the wrong site (if the software is configured for multisite mode). 11. The wrong PIN has been entered (if the software is configured to use the PIN security feature). 1. The modem is turned off. 2. The wrong COM port has been selected in the Doors program. 3. The modem is the wrong type. Verify the modem cable is connected to the master controller in the access control network. Verify the JP3 INT_MODEM jumper (see Figure 1 on page 1) is NOT on JP3 when using an external modem. Verify the master controller is an EntraGuard Gold (not a PXL). Verify the master controller s address is 1. In the Doors program, click on the Select Site button and verify the correct site has been selected. In the Doors program, verify the PIN is correct in the Setup > System > Sites menu option. Verify the modem s power is on. In the Doors program, verify the correct COM port has been selected in the Setup > System > Network Configuration menu option. Refer to the modem s manual and verify the modem is Hayes compatible, communicates at 9600 baud or greater, can be configured to turn error checking off, and has nonvolatile RAM backup. Reference Document Web: [email protected] Page 7 of 18
8 Reference Document Troubleshooting and Diagnostics Problem Possible Cause Corrective Action The lock relay continually cycles on and off. The Doors program will not run. Some controllers on the access control network are not communicating with the Doors program. 4. The host PC to modem cable is not correct. 5. The host computer s serial port has an incompatible UART. 6. There is an IRQ conflict. 7. The COM port is not working. 1. The firmware PROM is not seated properly. 1. The host PC does not have enough conventional memory available for the program. 1. There is an addressing conflict between the controllers. If the installation uses a Keri Systems cable, verify the correct cable has been installed. If the installation uses a self-made cable, refer to the instructions provided in the EntraGuard Gold Quick Start Guide (P/N ) to verify the cable has been wired correctly. The serial port must have a UART. Consult a computer technician to resolve this problem. Consult a computer technician to resolve this problem. Consult a computer technician to resolve this problem. Turn controller power off. Refer to Figure 1 on page 1, locate the firmware PROM, and ensure the PROM is seated properly in its socket on the main board. Now follow the instructions provided in the EntraGuard Gold Quick Start Guide (P/N ) to reset the controller s RAM. The host PC must have at least 560K of conventional memory available for use by the Doors program. Consult a computer technician to resolve this problem. Check the address on each controller on the network. Each controller must have a unique address. The master controller must be an EntraGuard Gold controller with the address set to 1. Web: [email protected] Page 8 of 18
9 Troubleshooting and Diagnostics Problem Possible Cause Corrective Action Cardholder name not showing in directory list on EntraGuard LCD 2. RAM is corrupted in one or more of the controllers. 3. The access control network is not wired correctly. 4. Controllers are not powered on. 5. No power or insufficient power has been supplied to the system. 1. User ID not enrolled as an EntraGuard ID. In the Doors program, click on Setup > System > Controller Status menu option. Select each controller, one-ata-time, and click on the Status button. Note those controllers that do not respond or that respond incorrectly. These controllers must have their RAM reset. Follow the instructions provided in the EntraGuard Gold Quick Start Guide (P/N ) to reset the controller s RAM. Review the access control network wiring on each controller. Verify the network wiring is connected correctly. Verify all connections have been made on lead wire and not on wire insulation. Verify all controllers are powered on. Check the main power circuit breaker. Verify the positive power lead is on TB-2, pin 1 and the negative power lead is on TB-2, pin 2 (see Figure 1 on page 1). Measure the input voltage across pin 1 (positive) and pin 2 (negative) of TB- 2. The voltage should read between 12 and 14 VDC. Disconnect the power supply from the controller and verify the supply s voltage. The voltage should read between 12 and 14 VDC. Verify there is a proper earth ground. Make sure the EntraGuard ID option is selected when enrolling User IDs in Doors. See the Doors Users Guide (P/N ) for how to enroll User IDs. Reference Document Web: [email protected] Page 9 of 18
10 Reference Document Troubleshooting and Diagnostics Problem Possible Cause Corrective Action User ID denied access 2. User ID not turned ON. In Doors, verify the ON/OFF cell is set to ON in the Setup Cards window. 3. No access group assigned. 4. No phone number listed. 5. Name displayed disabled. 1. User ID not enrolled as an EntraGuard ID In Doors, verify a valid Access Group has been assigned in the Setup Cards window. In Doors, verify the correct phone number has been entered for each cardholder (including any necessary area codes) in the Setup Cards window. In Doors, verify the Name Displayed cell is set to ON in the Setup Cards window. Make sure the EntraGuard ID option is selected when enrolling User IDs in Doors. See the Doors Users Guide (P/N ) for how to enroll User IDs. 2. User ID not turned ON. In Doors, verify on the Setup Cards spreadsheet that the ON/OFF cell is set to ON. 3. Not entering all numbers in the User ID. 4. Wrong access rights assigned to cardholder. 5. Changes in Doors software not saved and updated in controller. If the User ID number of digits (in the System Options window in Doors) is set for a specific number of digits (5 for example), then 5 digits must be entered (including any leading 0s). Verify the time zone and access group assigned to the cardholder in the Doors software. Verify all changes made in the Doors software has been saved, then perform an update on the controller and/or network. Web: [email protected] Page 10 of 18
11 Troubleshooting and Diagnostics Problem Possible Cause Corrective Action Telephone command does not perform function 1. The function may not be turned on in the Doors software. 2. No number was programmed for the function in the Doors software. 3. Pressing wrong telephone key for command. In Doors, verify in the System Options page that the telephone entry option is turned on and a number has been assigned for each function. Then verify you are selecting the correct number on the telephone. In Doors, verify the telephone key assigned for the specific task on the System Options page is the correct number. Reference Document Web: [email protected] Page 11 of 18
12 Reference Document Troubleshooting and Diagnostics 2.0 Set Microphone Volume The EntraGuard Gold controller comes with the microphone gain set at 3. However, after installing the controller and testing the system, by contacting a tenant through the controller, you may find that the microphone gain needs to be adjusted. To change the microphone gain, power up the EntraGuard unit while pressing the S1 button (see Figure 1 on page 1). The Reset Menu will appear (see Figure 3). Figure 3: Reset Menu From the Reset Menu, select number 3 on the keypad and the Set Microphone Vol Menu will appear (see Figure 4). Figure 4: Set Microphone Volume The factory default is set at 3. To increase the microphone gain, enter a higher number (4 or 5). To decrease the microphone gain, enter a lower number (1 or 2). Once the new level has been set, select the * key to save the new choice, or CLEAR to cancel the change. NOTE: If the EntraGuard Gold controller is located adjacent to a busy street, it is best to test the unit during peak traffic times as this will influence the microphone gain level needed for acceptable communication. Web: [email protected] Page 12 of 18
13 Troubleshooting and Diagnostics 3.0 Diagnostics Built into every EntraGuard Gold controller is a set of diagnostic programs designed to assist in field verification of controller functions. To reach the diagnostic menu, power up the EntraGuard unit while pressing the S1 button (see Figure 1 on page 1). The Reset Menu will appear (see Figure 3 on page 12). Select 4 on the keypad and the Diagnostics Menu will appear (see Figure 5). Figure 5: Diagnostics Menu There are four diagnostic screens available, each of which is described in the following sections. Reference Document Input Levels Output States Net Activity Keypad Signal Web: [email protected] Page 13 of 18
14 Reference Document Troubleshooting and Diagnostics 3.1 Input Levels The Input Levels screen allows you to monitor the status of the inputs. From the Diagnostics Menu (see Figure 5 on page 13), select number 1 on the keypad to reach the Input Levels screen. The screen will appear on the LCD (see Figure 6). Figure 6: Input Levels Menu KPAD - indicates which Keypad characters are displayed. This is selected by using the JP2 KP_Select jumper. A/N - both alpha and numeric characters are displayed NUM - only numeric characters are displayed PGM - indicates which communication port is used for programming INT - indicates the phone line port is being used (Master only) EXT - indicates the RS-232 port is being used (Master only) indicates the slave unit is using the 485 for communication PWR - indicates the voltage of the EntraGuard power supply. For the following inputs, 000 indicates a closed state and 255 indicates an open state. PSW - indicates the current state of the Postal Switch input DSW - indicates current state of the door input RTE - indicates current state of the RTE input AUX1 - indicates the current state of the AUX1 input AUX2 - indicates the current state of the AUX2 input Web: [email protected] Page 14 of 18
15 Troubleshooting and Diagnostics 3.2 Output States The Output States screen allows you to monitor the status of the outputs. From the Diagnostics Menu (see Figure 5 on page 13), select number 2 on the keypad to reach the Output States screen. The screen will appear on the LCD (see Figure 7). Figure 7: Output States Relay K5 - Door Lock K6 - Door Alarm K7 - AUX 1 K8 - AUX 2 To change the state of one of the outputs, select the key on the EntraGuard Gold Controller keypad that corresponds to the Activate Number of the output you want to change. The Current State will reflect the change and remain after exiting Diagnostics. Reference Document Web: [email protected] Page 15 of 18
16 Reference Document Troubleshooting and Diagnostics 3.3 Net Activity The Net Activity screen performs two different functions, depending on whether the controller is a master or a slave. From the Diagnostics Menu (see Figure 5 on page 13), select number 3 on the keypad to reach the Net Activity screen Master Controller On the master controller, the Net Activity screen displays any 485 network errors (see Figure 8). Figure 8: Net Activity - Master Controller Cur - indicates 485 network errors for the current poll Cyc - indicates 485 network errors for the current polling cycle Acc - indicates the total 485 network errors Web: [email protected] Page 16 of 18
17 Troubleshooting and Diagnostics Slave Controller On the slave controller, the Net Activity screen shows you whether or not the master controller is polling the slave. Figure 9: Net Activity - Slave Controller The number indicates, in seconds, the period between polls from the master. This number will vary depending on the size if the network, a larger network would require more time between polls. Contact tech support if any of the following occurs: EntraGuard units on the same network show different numbers. The polling period indicates 000, which means the master is never polling the slave unit. The polling period changes from day to day. The polling period should remain constant unless a change has been made to the size of the network by either adding or removing controllers. Reference Document NOTE: When checking the Net Activity on a slave controller, the number will repeatedly change as the master controller finishes polling. For a correct reading, wait until the number becomes stable. Web: [email protected] Page 17 of 18
18 Reference Document Troubleshooting and Diagnostics 3.4 Keypad Signal The Keypad Signal screen allows you to test the keypad LED matrix. From the Diagnostics Menu (see Figure 5 on page 13), select number 4 on the keypad to reach the Keypad Signal screen. The screen will appear on the LCD (see Figure 10). Figure 10: Keypad Signal The first group of dashes represent the rows of LEDs on the keypad. The second group of dashes represent the columns of LEDs on the keypad. When a set of LED beams are broken, by placing your finger over a key, one dash from each group will move down to indicate the LED matrix beam has been broken. When the beam is no longer broken, the dashes return to their previous location. Which dashes move depend on where the LED is located on the keypad. The best way to check the keypad signal is by running your finger along the red bezel surrounding the keypad with your finger just barely above the keypad. NOTE: The Keypad Signal Diagnostic is set up so that activating any lit key will send you back to the Diagnostics menu. When no LED beams are being broken, the dashes must remain above the half-way point. If any of the dashes are below the half-way point on the LCD (see Figure 11), try cleaning off the red bezel surrounding the keypad. If the dash continues to register below the half-way point when not being selected, contact technical support for further instructions. Figure 11: Keypad Signal with Half-way Point Shown Web: [email protected] Page 18 of 18
Troubleshooting and Diagnostics
Troubleshooting and Diagnostics The troubleshooting and diagnostics guide provides instructions to assist in tracking down the source of many basic controller installation problems. If there is a problem
NOTE: It is the responsibility of the installation organization to have only technically qualified personnel performing the installation.
This quick start guide provides, basic installation information, drawings, first time power-on instructions, and short descriptions of key terms and concepts for installing the EntraGuard Platinum Telephone
Doors for use with Windows
Doors for use with Windows Access Control Software Users Guide v2.1 1998 Keri Systems, Inc. ALL RIGHTS RESERVED Document Number 01821-001, Revision 2.1 October, 1998 Keri Systems, PXL-250, SB-293, Tiger
RKAT Audit Trail Module RK-LINK TM Software For the Radio Key 600 Series
RKAT Audit Trail Module RK-LINK TM Software For the Radio Key 600 Series INSTALLATION & OPERATING GUIDE Rev. B P/N 3321515 20301 NORDHOFF STREET CHATSWORTH, CA 91311 PHONE (818) 882-0020 FAX (818) 882-7052
TX3 Series TELEPHONE ACCESS SYSTEMS. Configurator Quick Start. Version 2.2 Mircom Copyright 2014 LT-973
TX3 Series TELEPHONE ACCESS SYSTEMS Configurator Quick Start Version 2.2 Mircom Copyright 2014 LT-973 Copyright 2014 Mircom Inc. All rights reserved. Mircom Configurator Software Guide v.2.2 for Windows
PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL
Rev. D PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL 10 BORIGHT AVENUE, KENILWORTH NEW JERSEY 07033 TELEPHONE: 800-524-0273 FAX: 908-686-9317 TABLE OF CONTENTS Page
Doors User Data File Export/Import
The Doors User Data File Export/Import feature allows a systems integration expert to import selected and limited user information from an external application (such as Excel or some similar spreadsheet
FAQs. XAP Frequently Asked Questions. Software/Configuration
XAP Frequently Asked Questions ~ Software/Configuration ~ Echo Cancellation ~ Audio Performance ~ Expansion Bus ~ Firmware ~ Installation ~ Presets ~ Telephone Hybrid Software/Configuration What is the
AUDITVIEW USER INSTRUCTIONS
COMBOGARDPRO AUDITVIEW USER INSTRUCTIONS The ComboGard Pro AuditView software allows the Manager to view, save, and print the audit records. The ComboGard Pro lock maintains the last 63 lock events in
AC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
V2.0 Attendance System Hardware Suite Guide Instructions Manual
CONTENTS TA920 V2.0 Attendance System Hardware Suite Guide Instructions Manual Chapter One - Introduction 1.1 Communication Port 5 1.2 Power Source Control. 5 1.3 Attendance Users. 6 1.4 Registering Ways..
SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision 090210 [Version 2.2]
SMS Alarm Messenger SMSPro_Setup Revision 090210 [Version 2.2] ~ 1 ~ Contents 1. How to setup SMS Alarm Messenger?... 3 2. Install the SMSPro_Setup software... 5 3. Connection Type... 6 4. Connection Port
GSM Desktop phone DPH101. User manual v1.00
GSM Desktop phone DPH101 User manual v1.00 LEGAL NOTICE Copyright 2011 TELTONIKA Ltd. All rights reserved. Reproduction, transfer, distribution or storage of part or all of the contents in this document
CipherLab 5100 Time Attendance Utility Manual
CipherLab 5100 Time Attendance Utility Manual K:\Products\Product Technical\BI\BI-PC5100T\CipherLab5100TimeAttendnaceUtilityManual0707-process.doc Page 1 / 13 1 Login A popup form as follows will appear
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version
Global Water Instrumentation, Inc.
Global Water Instrumentation, Inc. 151 Graham Road P.O. Box 9010 College Station, TX 77842-9010 Telephone : 800-876-1172 International : (979) 690-5560, Fax : (979) 690-0440 e-mail : [email protected]
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
OWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC. www.signalcrafters.com
OWNERS MANUAL Status Monitor for Windows 95, 98, ME, NT 4, 2000 & XP SIGNALCRAFTERS TECH, INC. www.signalcrafters.com 57 Eagle Rock Avenue, East Hanover, NJ 07936 Tel: 973-781-0880 or 800-523-5815 Fax:
Ethernet Radio Configuration Guide
Ethernet Radio Configuration Guide for Gateway, Endpoint, and Repeater Radio Units April 20, 2015 Customer Service 1-866-294-5847 Baseline Inc. www.baselinesystems.com Phone 208-323-1634 FAX 208-323-1834
ProVisual AC-8000P. User Manual. For the optimal use and maintenance of the product, Please read the manual carefully before using it.
ProVisual AC-8000P User Manual For the optimal use and maintenance of the product, Please read the manual carefully before using it. Table of Content Chapter One Handling Instruction... 3 1.1 Operation
AUDITVIEW USER INSTRUCTIONS
The AuditGard AuditView software allows the Manager to view, save, and print the audit records. The AuditGard lock maintains the last 512 lock events in non-volatile memory. Accessing the audit records
NetworX TM NX-8E Alarm Panel. Application Note. NetworX NX-8E. 1.0 The NetworX NX-8E Alarm Panel
The PXL-510 tiger controller can be connected with the NetworX 1 NX-8E Alarm panel to allow arming and disarming of the alarm system by using the alarm panel keypad, using a wireless Wiegand device, or
INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.
SA-2000-II HARDWARE MANUAL Access Technologies International, Inc. 1 Table of Contents 1. Introduction 3 2. Features 3 3. Specification 4 4. Identifying Supplied Parts 4 5. Panel Description 5 6. Connection
History of Revisions. Ordering Information
No part of this document may be reproduced in any form or by any means without the express written consent of II Morrow Inc. II Morrow, Apollo, and Precedus are trademarks of II Morrow Inc. Windows is
Time Attendance V1.4
Time Attendance V1.4 Installation Manual May 11, 2011 Page 1 TABLE OF CONTENTS 1. TIME ATTENDANCE...5 2. SOFTWARE INSTALLATION...6 3. SETTING UP THE TIME ATTENDANCE SYSTEM...7 3.1 Set Password...7 3.2
Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM PRODUCTS AFFECTED SYMPTOMS POSSIBLE CAUSES
Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM COMMUNICATIONS WITH AN OCTOPUS. Article # 072297-1 Last reviewed: 03/25/98 Keywords: Serial Port, Modem, Polling, AquaWeb, Node Not Responding
Setting Up the ZigBee Ethernet Gateway
Setting Up the ZigBee Ethernet Gateway MAN-01-00030-1.4 This manual describes how to install and set up ZigBee communication between a SolarEdge device (Inverters or Safety and Monitoring Interface) and
About This Guide SolarEdge Configuration Tool Software Guide. About This Guide
About This Guide 3 About This Guide This user guide is intended for Photovoltaic (PV) system owners, installers, technicians, maintainers, administrators and integrators who are authorized to configure
How To Connect A Directsofl To A Powerpoint With An Acd With An Ctel With An Dm-Tel Modem On A Pc Or Ipad Or Ipa (Powerpoint) With A Powerline 2 (Powerline
Application Note Last reviewed: 03/17/2008 AN-KEP-003.doc Page 1 of 23 Introduction... 1 Recommended s and ports to use... 1 Cable Wiring... 2 MDM-TEL Configuration ( Wizard)... 3 Direct Logic Communications
MINIMUM TOOL REQUIREMENT FOR EPROM UPGRADE
Installing and Updating SE422 Access Control Units Firmware! Read all procedures before attempting the field replacement of the EPROM firmware in any equipment. Components are static sensitive and care
1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear.
SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS WINLOAD MODEM SETUP The modem setup is a very important step in the connection process. If the modem setup is not properly completed communication between
PXL-500 / PXL-510 Tiger Controller Quick Start Guide
This quick start guide provides, basic installation information, drawings, first time power-on instructions, and short descriptions of key terms and concepts for installing controllers. These instructions
Bluetooth to Serial Adapter
Bluetooth to Serial Adapter Third Edition, Oct 2007 Version 3.0 771-BTS1009C3-001 Contents 1.0 Features....P.2 2.0 Package Content....P.2 3.0 Hard Drives Requirement.P.2 4.0 Specifications.P.3 5.0 Pin
Knowledge Base Article. Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers
Knowledge Base Article Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers Copyright 2009-2012, ISONAS Security Systems All rights reserved Table of Contents 1: INTRODUCTION...
ECcom. Signal Monitor Communications Software Operations Manual
ECcom Signal Monitor Communications Software THIS MANUAL CONTAINS TECHNICAL INFORMATION FOR THE ECcom SIGNAL MONITOR COMMUNICATIONS SOFTWARE. SOFTWARE VERSION 4.0 REVISION: JUNE 2014 pn 888-1000-001 INFORMATION
NortechCommander Software Operating Manual MAN-00004 R6
NortechCommander Software Operating Manual MAN-00004 R6 If the equipment described herein bears the symbol, the said equipment complies with the applicable European Union Directive and Standards mentioned
Supplemental User Guide
Supplemental User Guide SUPPLEMENTAL GUIDE FOR UPDATG FIRMWARE ON Z-MAX TM LIGHTG CONTROL RELAY PANELS WITH MASTER CONTROL MODULE Software revision.00 an up LIT-ZMAXS-00 Rev A, August 2004 Technical Services:
1. MOXA NPort Express TCP/IP to RS-232 server
GS_GSR_GCR_UserManual_App_E_MOXA_V01.doc / 17.08.2009 GeoSIG Ltd. Appendix E Page E-1 1. MOXA NPort Express TCP/IP to RS-232 server 1.1. General Explanations The NPort Express RS-232/422/485 Device server
DPH-50U VoIP USB Phone Adapter Quick User Guide
DPH-50U VoIP USB Phone Adapter Quick User Guide Version 1.0 TABLE OF CONTENTS 1. INTRODUCTION...3 2. PACKAGE CONTENTS...4 3. REQUIREMENTS...5 4. DPH-50U INSTALLATION...6 5. ENABLING DPH-50U...16 6. DPH-50U
To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:
PURPOSE Verify that communication is established for the following products programming option (488.2 compliant, SCPI only): DCS - M9C & DCS M130, DLM M9E & DLM-M9G & DLM M130, DHP - M9D, P series, SG,
RS232 Programming and Troubleshooting Guide for Turbo Controls
RS232 Programming and Troubleshooting Guide for Turbo Controls This Troubleshooting guide is intended for the set up and troubleshooting of the control panels onboard RS232 output. Refer to the Installation
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE
Sierra S-Series Smart Interface Software User Manual
Sierra S-Series Smart Interface Software User Manual Part Number IM-SIP 08/99 Revision B 5 Harris Court, Building L Monterey, CA 93940 (831) 373-0200 (800) 866-0200 Fax (831) 373-4402 http://www.sierrainstruments.com
Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI
Technical Manual For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI Caller ID.com WHOZZ CALLING? POS 2 Caller ID Monitoring Unit Technical Manual For use with Caller ID signaling
32 Transferring Projects and Data
32 Transferring Projects and Data This Chapter explains how to transfer GP-Pro EX project files to the GP and how to transfer the project files stored on the GP to your PC. Please start by reading 32.1
Configuring Napco Integration
Configuring Napco Integration The following instructions will guide you through the CardAccess Napco Integration with TCP/IP communication setup. Note: It is assumed that Napco Panel (including TCP/IP
Application Note 2. Using the TCPDIAL & TCPPERM Commands to Connect Two TransPort router Serial Interfaces Over TCP/IP.
Application Note 2 Using the TCPDIAL & TCPPERM Commands to Connect Two TransPort router Serial Interfaces Over TCP/IP. Reverse Telnet or Serial Terminal Server MultiTX feature UK Support March 2014 1 Contents
Bluetooth HC-06 with serial port module Easy guide
1 Bluetooth HC-06 with serial port module Easy guide This manual consists of 3 parts: PART 1. Overview of Bluetooth HC-06 module with serial port. PART 2. Installing Bluetooth HC-06 module with Bolt 18F2550
ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4
ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4 1 PURPOSE:... 1 2 CPM-4/CPM-2 COMPATIBILITY... 2 2.1 NETWORK CABLES... 2 2.2 FACTORY DEFAULT SETTINGS... 2 2.3 CHANGING THE RS-232 SERIAL PORT BAUD
OA101 Fingerprint Time attendance system Preface
Preface Honorable customers, Thanks for choosing products of this company. OA101, with world cutting edge technologies fingerprint recognition, computer communication, as well as microelectronics, is considered
Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation
Quick Installation A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding This chapter intends to get your new FuzzyScan scanner working with your existing system within minutes. General instructions
Allegion PIM-400/485 and AD-400 Installation Application Note. 1.0 Hardware Requirements. 2.0 Software/Licensing Requirements
This document explains how to setup and use the Allegion AD-400 wireless locks with the NXT Mercury Powered controllers and the Doors.NET software. These locks have extensive functionality and operating
AutoWAVE. Programming Instructions P/N 1-0479-014. Part of Thermo Fisher Scientific. Revision D
AutoWAVE Programming Instructions P/N 1-0479-014 Revision D Part of Thermo Fisher Scientific AutoWAVE Programming Instructions P/N 1-0479-014 Revision D 2007 Thermo Fisher Scientific Inc. All rights
M68EVB908QL4 Development Board for Motorola MC68HC908QL4
M68EVB908QL4 Development Board for Motorola MC68HC908QL4! Axiom Manufacturing 2813 Industrial Lane Garland, TX 75041 Email: [email protected] Web: http://www.axman.com! CONTENTS CAUTIONARY NOTES...3 TERMINOLOGY...3
Vicon Flash Upgrade Software
INSTRUCTION MANUAL Notes Refer to XX134 NO. XX134-13-01 REV. 1212 Vicon Flash Upgrade Software It is possible to upgrade software for the SurveyorVFT and Surveyor -Mini Camera Domes through a PC using
ServiceTools for MicroTech II Version 2.0 Applied Terminal Systems User Manual
User Manual UM 732-2 Group: Controls Part Number: UM 732-2 Date: May 2004 Supersedes: UM 732-1 ServiceTools for MicroTech II Version 2.0 Applied Terminal Systems User Manual 2004 McQuay International Contents
Animated Lighting Software Overview
Animated Lighting Software Revision 1.0 August 29, 2003 Table of Contents SOFTWARE OVERVIEW 1) Dasher Pro and Animation Director overviews 2) Installing the software 3) Help 4) Configuring the software
Crow Limited Warranty. Print Version 017
Crow Limited Warranty (Crow) warrants this product to be free from defects in materials and workmanship under normal use and service for a period of one year from the last day of the week and year whose
Cyberex BCM-SFCM Configurator/Monitor User's Manual
BRANCH/SUBFEED CIRCUIT MANAGEMENT Cyberex BCM-SFCM Configurator/Monitor User's Manual Updated: 04/01/13 Thomas & Betts Power Solutions 5900 Eastport Boulevard Richmond, VA 23231-4453 Tel: 800-238-5000
CM6700 Matrix Switcher/Controller
CM6700 Matrix Switcher/Controller Installation/ Operation Manual C523M-H (6/05) Pelco 3500 Pelco Way Clovis, CA 93612-5699 USA www.pelco.com In North America and Canada: Tel (800) 289-9100 FAX (800) 289-9150
Software User Guide UG-461
Software User Guide UG-461 One Technology Way P.O. Box 9106 Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 Fax: 781.461.3113 www.analog.com ezlinx icoupler Isolated Interface Development Environment
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
Installation Instructions For Controllers with MS/TP Automatic MAC Addressing. Patent Pending 000-019-01
Installation Instructions For Controllers with MS/TP Automatic MAC Addressing Patent Pending 000-019-01 KMC Controls Important notices Disclaimer 2009, KMC Controls, Inc. TotalControl, BACstage and FullBAC
INSTRUCTION MANUAL. Installing the Software NO. XX134-24-00. NOTES Refer to XX134 REV. 510 SEC. 3
INSTRUCTION MANUAL NOTES Refer to XX134 NO. XX134-24-00 REV. 510 Vicon Direct Control Software It is possible to control the SurveyorVFT or Surveyor -Mini camera dome from a PC using the Direct Control
SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS. Quick Start Instructions
TM SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS Quick Start Instructions Introduction WinLoad for Windows was developed to simplify and speed up the task of programming Paradox control panels. Remote
Laser Barcode Scanner
Laser Barcode Scanner User s Manual FCC Compliance This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
APPLICATION NOTE. The DMP Software Family DMP COMPUTER SOFTWARE PROGRAMS
APPLICATION NOTE Contents The DMP Software Family... 1 Stand-Alone Link Software... 1 Add-on Modules for Link Software... 1 System Link End-User Panel Management Software... 2 Simple Registration and Activation...
PHONE MANAGER INDEX. page
PHONE MANAGER INDEX page 1 HARDWARE... 4 1.1 Requirements... 4 1.2 Indicators... 4 1.3 Hardware Configuration... 5 1.4 Hardware Installation... 5 2 SOFTWARE... 7 2.1 Software Installation... 7 2.2 Use
HelpAndManual_unregistered_evaluation_copy
HelpAndManual_unregistered_evaluation_copy 2 Acclima Access User Guide Table of Contents Introduction... 3... 3 System Requirements Features... 3 Installation... 3 Controller... Configuration 4... 4 Controller
Communication Setup Application Note
Communication Setup Application Note This Application Note describes how to install and set up communication between the inverter and the SolarEdge Monitoring Server. This document contains the following
Access Control Software Manual
CONTENTS 1. Function overview...1 2. Installation environment...2 3. Concept description...3 4. Installation and Uninstallation...4 4.1 Installation...4 4.2 Uninstallation...10 5. Function instroduction...11
2100 POS System. 2100 User Guide
2100 POS System 2100 User Guide Thank you for selecting UTC RETAIL s innovative Model 2100 Point of Sale solution! This guide is designed to acquaint you with the features and functionality of the 2100
LEN s.r.l. Via S. Andrea di Rovereto 33 c.s. 16043 CHIAVARI (GE) Tel. +39 0185 318444 - Fax +39 0185 472835 mailto: [email protected] url: http//www.len.
MA511 General Index 1 INTRODUCTION... 3 1.1 HARDWARE FEATURES:... 4 2 INTERFACE... 5 2.1 KEYBOARD... 6 2.2 POWER ON... 7 2.3 POWER OFF... 7 2.4 DETECTOR CONNECTION... 7 2.5 DETECTOR SUBSTITUTION...7 3
Memcom Emergency Telephone
Memcom Emergency Telephone Installation Guide Ref No. 450 900 (GB) Version 2 + + Simple wiring for quick installation + + Integrated LCD display shows you what you have programmed + + All code based programming
Operating Instructions for the Software Fingerprint Access System FP530
GB Operating Instructions for the Software Fingerprint Access System FP530 Table of Contents GB Page 1. Introduction...3 2. Short description of the FP530-PC software...3 3. Explanation of Symbols...3
How to read this guide
How to read this guide The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example P oint Reference Caution [ ] This symbol explains information
Using HyperTerminal with Agilent General Purpose Instruments
Using HyperTerminal with Agilent General Purpose Instruments Windows HyperTerminal can be used to program most General Purpose Instruments (not the 531xx series counters) using the RS-232 Serial Bus. Instrument
BiPAC 7800NL. Wireless-N ADSL2+ Firewall Router. Quick Start Guide
BiPAC 7800NL Wireless-N ADSL2+ Firewall Router Quick Start Guide BiPAC 7800NL Wireless-N ADSL2+ Firewall Router Billion BiPAC 7800NL Wireless-N ADSL2+ Firewall Router PLEASE READ THE QUICK START GUIDE
GSM Door Phone System
GSM Door Phone System System Installation, Setting and Operation Manual User Manual (263-S V1) Please read this user manual completely before operating this system and keep it in a safe place for future
APR-PRT3 Printer Module: C-Bus Programming Instructions
APR-PRT3 Printer Module: C-Bus Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send us
T3 Mux M13 Multiplexer
T3 Mux M13 Multiplexer User Manual [Type the abstract of the document here. The abstract is typically a short summary of the contents of the document. Type the abstract of the document here. The abstract
EDI Distributor Control Interface Wiring and Setup Instructions
Universal I/O EDI Distributor Control Interface Wiring and Setup Instructions EDI UNIVERSAL I/O INTERFACE MODULE The only interface needed for EDI-V5 controls Network compatible with all older EDI controls
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
SIS-PM / SiS-PM-841 / SIS-PMS User Manual. Table of contents
Silver Shield Power Manager Silver Shield Power Manager 841 Silver Shield Power Manager S (With built-in power supply unit) 2 Table of contents 1. Introduction and features of the SiS-PM/SiS-PM-841/SiS-PMS
EMBEDDED ACCESS CONTROL Hardware Installation Guide
EMBEDDED ACCESS CONTROL Hardware Installation Guide Lenel goentry Hardware Installation Guide, product version 1.00. This guide is item number DOC- ENHW-ENU, revision 1.003, April 2009 Copyright 2009 Lenel
Keep it Simple Timing
Keep it Simple Timing Support... 1 Introduction... 2 Turn On and Go... 3 Start Clock for Orienteering... 3 Pre Start Clock for Orienteering... 3 Real Time / Finish Clock... 3 Timer Clock... 4 Configuring
SAFEPATH 4 Telephone Zone Controller
SAFEPATH 4 Telephone Zone Controller SP4-TZC P/N 109921 SP4-TZC-P P/N 105590 Installation, Testing, Operation and Maintenance Manual 273 Branchport Avenue, Long Branch, NJ 07740-6899 Ph: (800) 631-2148
SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2
SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2 USER MANUAL Rev. P1.11 September 13, 2006 DeltaV is a trademark of Emerson Process Management, Inc Emerson Process Management, Inc. 1998,
Date Rev. Details Author
Jtech engineering ltd J - Te c h E n g i n e e ring, L t d. 11080 Bond Boulevard Delta BC V4E 1M7 Canada Tel: 604 543 6272 Fax: 604 543 6476 http://www.jtecheng.com AUTODIALER USER S MANUAL REVISION HISTORY
In-System Programmer USER MANUAL RN-ISP-UM RN-WIFLYCR-UM-.01. www.rovingnetworks.com 1
RN-WIFLYCR-UM-.01 RN-ISP-UM In-System Programmer 2012 Roving Networks. All rights reserved. Version 1.1 1/19/2012 USER MANUAL www.rovingnetworks.com 1 OVERVIEW You use Roving Networks In-System-Programmer
English version. LW320/LW321 Sweex Wireless 300N Router. Package Contents. Terminology list
LW320/LW321 Sweex Wireless 300N Router Do not expose the Sweex Wireless 300N Router to extreme temperatures. Do not place the device in direct sunlight or in the direct vicinity of heating elements. Do
Troubleshooting. Troubleshooting - 1
Troubleshooting Troubleshooting - 1 Issue 2 Modem Does Not Answer Modem Does Not Answer There is no power to the modem. The modem is not connected. Check the power source. The modem should be connected
Plena Voice Alarm System. Software Manual Configuration Software
Plena Voice Alarm System en Software Manual Configuration Software Plena Voice Alarm System Software Manual Table of Contents en 3 Table of Contents Table of Contents...3 1. Introduction...7 1.1 Purpose...7
Winlead Dialer Software Users Manual Addendum 3 Installing Winlead Dialer Software on the Windows 2000 System
Winlead Dialer Software Users Manual Addendum 3 Installing Winlead Dialer Software on the Windows 2000 System Copyright 2002 by Winlead Dialer Software 1.0 - Install Guide for Winlead Dialer Software Software
The Analyst RS422/RS232 Tester. With. VTR, Monitor, and Data Logging Option (LOG2) User Manual
12843 Foothill Blvd., Suite D Sylmar, CA 91342 818 898 3380 voice 818 898 3360 fax www.dnfcontrolscom The Analyst RS422/RS232 Tester With VTR, Monitor, and Data Logging Option (LOG2) User Manual Manual
This document describes the standard software installation process for Doors.NET software.
Doors.NET installation and controller configuration is a three step process. Each of these steps has its own document, with controller configuration broken into separate documents per hardware type. software
8 Channel Status Input Panel model SIP-8
Description The Sine Systems model SIP-8 Status Input Panel is to be used with the RFC-1/B Remote Facilities Controller. It consists of a long PC board mounted on a 1.75 inch (1U) rack panel. The SIP-8
Dear Customers, First of all thank you for purchasing our. product, the Fingerprint Time Attendance. Machine! For the optimal use and maintenance of
Dear Customers, First of all thank you for purchasing our product, the Fingerprint Time Attendance Machine! For the optimal use and maintenance of the product, Please read the manual carefully before using
Internal Modem Installation with Windows 95
Internal Modem Installation with Windows 95 You will need these items from your U.S. Robotics modem box: modem phone cord Plus: a screwdriver (not included) Determining Available Resources Your U.S. Robotics