LIFT CONTROL SYSTEMS CATALOGUE 2007

Size: px
Start display at page:

Download "LIFT CONTROL SYSTEMS CATALOGUE 2007"

Transcription

1 LIFT CONTROL SYSTEMS CATALOGUE 2007 All Your Needs For Elevators

2 INDEX 1. Lift Control Cards Speed Control Units Emergency Rescue Cards Lift Control Panels Photocells Door Control Cards Inspection & Alarm Sets Other Products ALBEN İnşaat Makine Elektrik Elektronik San. ve Tic. Ltd. Şti 2/18

3 LIFT CONTROL CARDS ARL-500 Functional Programmable Lift Control Card All system parameters can be adjusted by using buttons and graphic LCD placed on the card; Can be used at any command type up to 48 floors; Can be used at one speed, two speed, speed controlled and hydraulic lifts without any extra parts. System can be selected from the menu; Can be used in group operation; All panels in the group are same and no extra panel is needed. Only thing to do is to set each panel as A, B and C in the program menu; Communication with car and floor panels is achieved via 2 cables. Fast and faultless wiring and reduction in cable cost are supplied by connected cabling; Reads the shaft data from magnetic counter system or encoder. When an encoder is used, braking and stopping adjustment can be made by using the buttons on the card or the buttons on the car panel. Can be used in high speed elevators; Saving errors on system with date and time information enables to track past errors in detail; Automatic door control according to the stops is achieved by double automatic door support; RS-232, RS-485 and 2 CAN BUS serial ports; Monitoring the lift status, giving commands, making adjustments and following errors are possible by a connection to a local computer via RS-232 or to a remote computer using a modem; 5 free inputs, 5 free transistorized outputs and 8 free relay outputs can be programmed and used for special purposes; No need for an external phase protection relay. Complete protection is provided by phase order, phase failure and motor thermistor control placed on the card. These protections can be deactivated or activated via menu; Designed according to European Lift Standard EN-81. ALBEN İnşaat Makine Elektrik Elektronik San. ve Tic. Ltd. Şti 3/18

4 LIFT CONTROL CARDS ARL-300 Functional Programmable Lift Control Card Designed according to European electric and hydraulic lifts directive EN81-1/2; Integrated door bridging safety relays for door pre-opening while approaching the floor and re-leveling with open door; Integrated motor-phase protection relay; Integrated automatic door control inputs and outputs; Binary or grey code outputs for LCDs and Dot Matrix Displays; Easily installed and safe detected shaft information gathering system; Can be used at any command type up to 24 floors; Can be used in group operation. All panels in the group are same and no extra panel is needed. Only thing to do is to set each panel as A, B and C in the program menu. Only two cables are needed for group communication; All system parameters can be adjusted by user via buttons and LCD on the card; At normal condition the lift can be monitored by messages on the LCD. (Waits for calls, high speed, low speed, inspection). An error code with its explanation is displayed on the LCD at an abnormal condition. (Ex. H1:Door can not locked); Each floor can be named by an alphanumeric character. (L, P, E, F, H, b, o, 0, 1, 2, 3..); 7-segment and signalization outputs are short-circuiting protected. In a short circuit case the concerned output is shut down until problem is removed and a message stating which output is short-circuited is displayed on the LCD. (D segment short-circuited); Only 15 cables are enough for system to work by using serial car connection (FX_SERI) which reduces labor and cable costs; Emergency lowering with 2 pieces of 12V batteries. ARL-300 Charge Card controls the battery charge; Connection cards, which are used instead of panel terminals, are supplied with flexible parallel connection cables thereby saving extra connection terminals on control panel. ALBEN İnşaat Makine Elektrik Elektronik San. ve Tic. Ltd. Şti 4/18

5 LIFT CONTROL CARDS ARL-200S Functional Programmable Lift Control Card All system parameters can be adjusted by using buttons and LCD placed on the card; Can be used at any command type up to 16 floors; Can be used in group operation; All panels in the group are same and no extra panel is needed. Only thing to do is to set each panel as A, B and C in the program menu; Compatible with VVVF drivers; Only two cables are needed for group communication; Floor detection is carried out by counter system. Only 3 magnetic switches for one speed and 4 for two speed systems including limit switches are used for any number of floors; An error code with its explanation is displayed on the LCD in case of an abnormal condition (e.g.. H1:Door can not be locked); At normal condition the lift can be monitored by messages on the LCD (Waits for calls, high speed, low speed, inspection); Each floor can be labeled by an alphanumeric character (L, P, E, F, H, b, o, 0, 1, 2, 3...); 7 Segment and signalization outputs are short-circuiting protected. In case of a short circuit, the related output is shut down until problem is removed and a message stating which output is in short-circuit is displayed on LCD (D segment short circuit); Only 15 cables are enough for system to work by using serial car connection (FX_SERI) which reduces labor and cable costs; No extra switch is needed at high speed lifts (1.6 m/sec) for early slow down; Designed according to European Lift Standard EN-81. ALBEN İnşaat Makine Elektrik Elektronik San. ve Tic. Ltd. Şti 5/18

6 LIFT CONTROL CARDS ARL-100 Control Card For Simple Systems Economical and practical control card for one / two speed systems up to 8 floors; System consists of only one unit (22 cm x 11 cm); Uses counter system for floor detection; regardless of the number of stops, 3 magnetic shelters in one speed systems, 4 magnetic shelters in two speed systems including limit shelters are adequate; All system parameters can be adjusted by using three buttons and a 7-segment display on the card (number of stops, busy delay, door lock waiting time, existence of an automatic door, maximum travel time between floors, fire alarm parking floor, door close delay, inspection parking floor); The current floor is displayed on the 7-segment display during normal operation. An error code with its explanation is displayed in case of an abnormal condition; Contains signal inputs for fire, earthquake, overload, full load, car priority switch; and outputs for direction arrows, car illumination, busy, out of service, and automatic door card; All digital and signalization outputs are short-circuiting protected; Designed to be compatible with EN-81 European Norm. ALBEN İnşaat Makine Elektrik Elektronik San. ve Tic. Ltd. Şti 6/18

7 SPEED CONTROL UNITS ADrive VVVF Inverter Can be used with open or closed loop systems; High dynamic performance; Contributes to energy-saving; Eliminates startup problems with generators by the help of controlled motor current; Thanks to Space Vector Modulation for high torque motor drive at all speeds; Exclusively designed for elevators. Special parameters for traveling comfort; Compatible with 5V - 24V, TTL, HTL, pnp output, npn output and totem pole output encoder types; 10 KHz IPM switching frequency for low noise motor drive; Integrated DC REACTOR (DCR); 4 low noise fans for efficient cooling; All control inputs and outputs are isolated; User friendly LCD menus for all parameters and faults; PC communication with RS-232 port; Control card communication with RS-485 port; DATA KEY for easy saving and transferring parameters; Overload, high voltage, low voltage, short circuit, power interruption, line phase control, over-heat, grounding fault, over-torque and other necessary protection functions. ALBEN İnşaat Makine Elektrik Elektronik San. ve Tic. Ltd. Şti 7/18

8 EMERGENCY RESCUE CARDS AKUS-SD Emergency Rescue Card In case of a mains failure, the lift stopped between two floors is moved to floor level, the automatic door is opened and passengers are evacuated safely; For lifts with automatic door, in case of a mains failure at floor level, the door is opened and passengers are evacuated; Can be installed in all one speed, two speed or speed-controlled systems; Powered by 5 batteries which need no maintenance; Thanks to Smart Battery Charge System which helps batteries to work for many years; With LCD program, parameters (max travel time, automatic door type, motor drive frequency, door opening time, starting delay, language, etc.) can be adjusted easily; Errors and system data are displayed on LCD; Can work open loop. without connecting a sensor to the motor; The AKUS-SD unit is integrated with control panel. All the connections necessary for emergency unit are done in factory. So the setup time is minimized. ALBEN İnşaat Makine Elektrik Elektronik San. ve Tic. Ltd. Şti 8/18

9 EMERGENCY RESCUE CARDS AKUS Emergency Rescue Card In case of a mains failure, the lift stopped between two floors is moved to floor level, the automatic door is opened and passengers are evacuated safely; For lifts with automatic door, in case of a mains failure at floor level, the door is opened and passengers are evacuated; Can be installed in all one speed, two speed or speed-controlled systems; Can be installed in any system regardless of the brand and type of control panel; In case the lift, stopped between two floors due to a control panel failure, can be moved to floor level by using a rescue button placed on the car panel; Powered by 5 batteries which need no maintenance; Thanks to Smart Battery Charge System which helps batteries to work for many years; The battery voltage and error codes are indicated by the display placed on the card; Can work open loop. without connecting a sensor to the motor; Power given to the motor is adjusted automatically, no manual adjustments are needed. ALBEN İnşaat Makine Elektrik Elektronik San. ve Tic. Ltd. Şti 9/18

10 LIFT CONTROL PANELS ARL-200S Lift Control Panels Driving Type: o One Speed, o Two Speed, o Speed Controlled, ACVV, VVVF, Open Loop, Closed Loop, o Hydraulic. Command Type: o Simple Push Button, o Up or Down Collective, o Selective Collective, o Group Operation. Automatic Door: o Semi Automatic, o Semi Automatic with Cabin Door, o Full Automatic. ALBEN İnşaat Makine Elektrik Elektronik San. ve Tic. Ltd. Şti 10/18

11 LIFT CONTROL PANELS AP-AKUS Emergency Rescue Panels In case of a mains failure, the lift stopped between two floors is moved to floor level, the automatic door is opened and passengers are evacuated safely, For lifts with automatic door, in case of a mains failure at floor level, the door is opened and passengers are evacuated, Can be installed in all one speed, two speed or speed-controlled systems, Can be installed in any system regardless of the brand and type of control panel, In case the lift, stopped between two floors due to a control panel failure, can be moved to floor level by using a rescue button placed on the car panel, Powered by 5 batteries which need no maintenance, Thanks to Smart Battery Charge System which helps batteries to work for many years, The battery voltage and error codes are indicated by the display placed on the card, Works open loop. No need to put a sensor on the motor, Power applied to the motor is adjusted automatically, no manual adjustments needed. ALBEN İnşaat Makine Elektrik Elektronik San. ve Tic. Ltd. Şti 11/18

12 LIFT CONTROL PANELS Lift Control Panels with Emergency Rescue System Emergency Rescue System is merged into control panel, To operate the Emergency Rescue System, only thing to do is to connect battery terminals besides normal connections of the panel, Possible damages to the Emergency Rescue System or Control Panel due to incorrect connections are eliminated. ALBEN İnşaat Makine Elektrik Elektronik San. ve Tic. Ltd. Şti 12/18

13 PHOTOCELLS FSL-FS64 Light Screen High sensitive protection with 64 infrared diodes (32 transmitter, 32 receiver); 3,000 mm working range; External 220V AC power supply; 10A relay contact output; seconds delayed buzzer output; 10 mm x 34 mm x 2,000 mm dimensions. FSL-1NPF One Sensor Light Barrier FSL-2NPF Two Sensor Light Barrier 1 infrared sensor in FSL-1NPF, 2 infrared sensors in FSL-2NPF; Composed of faced sensors; Has NO/NC relay contact output. ALBEN İnşaat Makine Elektrik Elektronik San. ve Tic. Ltd. Şti 13/18

14 DOOR CONTROL CARDS KM_BASIC Door Control Card (Folding Doors) Generally used for replacing old and problematic door cards. This card can be easily adapted to old door systems because an encoder is not needed. It has a fixed openingclosing speed; Powered by a separate battery (Card makes the battery charge), in case of a mains failure; The level of door stuck can be adjusted. KM_GOLD Door Control Card (Folding Doors) KM_DCVAR Door Control Card (Telescopic Doors) By the aid of encoder, travel curve of the door can be adjusted sensitively; Powered by a separate battery (Card makes the battery charge), in case of a mains failure; Door speed, stuck and brake parameters can be adjusted with potentiometers in KM_GOLD; with buttons in KM_DCVAR The parameters and the error codes are indicated on the display; Has a sound motion warning. ALBEN İnşaat Makine Elektrik Elektronik San. ve Tic. Ltd. Şti 14/18

15 INSPECTION & ALARM & ALARM SETS SETS RK12 Standard Inspection Box Has an emergency light output which turns on in case of a mains failure; Alarm, Gong, Battery charge, Inspection switch, Inspection movement buttons; Shelter for lamp, Emergency stop (locked), Socket, Lamp; Large inner volume for comfortable working environment. RK22 Serial Inspection Box Has all standard properties of RK12; FX_SERI (Serial Car Connection Card) is added; No installation is needed between the car and control panel for car buttons, display, overload, full load, gong, direction arrows, car lamp, automatic door close & open buttons and inspection movement buttons. Only security, power and communication connections are needed and 15 cables are enough for connection between car and control panel. EK-1 Manual Controller Manual control from control panel, Inspection switch, Inspection movement buttons; Emergency stop (locked). ALBEN İnşaat Makine Elektrik Elektronik San. ve Tic. Ltd. Şti 15/18

16 OTHER PRODUCTS FX_SERI Serial Car Connection Card Communicates with ARL-200S and ARL-300 control cards via two cables; No installation is needed between the car and control panel for car buttons, display, overload, full load, gong, direction arrows, car lamp, automatic door close & open buttons and inspection movement buttons. Only security, power and communication connections are needed and 15 cables are enough for connection between car and control panel. AUTO_KG Automatic Door Card Used with ARL-200S and ARL-100 control card; Can work with all three phase, single phase and electronic-controlled doors; Has light barrier input, door close input and door limit contact inputs; By using two potentiometers, the duration of light barrier's braking and door-open waiting at the floor can be adjusted. ALBEN İnşaat Makine Elektrik Elektronik San. ve Tic. Ltd. Şti 16/18

17 OTHER PRODUCTS REV1 Inspection Box Card Works with 24V supply voltage; 12V battery charge and emergency light outputs; Gong output, Alarm output. MKR-02C Motor Phase Protection Card Phase turn control, Adjustable phase voltage control, PTC control; 48V DC leakage current control, Warning LEDs. KUDS Cartop Display Driver Drives the display in car panel according to the signals from magnetic switches; Reduces cable and labor costs. ALBEN İnşaat Makine Elektrik Elektronik San. ve Tic. Ltd. Şti 17/18

18 OTHER PRODUCTS GKS Grey Code Driver Converts counter system data to Binary or Grey code. GEVEZE Voice Announcement System ChatterBox is a floor announcement system designed for elevators. It notifies the name or the number of the current floor with a human voice. It also gives overload and out of service warnings; Grey code, binary code and counter modes are available as input modes; ChatterBox board comes loaded with default messages from the factory. But it can also be customized with the help of a personal computer and the ChatterBox Loader Software. ALBEN İnşaat Makine Elektrik Elektronik San. ve Tic. Ltd. Şti 18/18

LIFT CONTROL SYSTEMS CATALOGUE 2007

LIFT CONTROL SYSTEMS CATALOGUE 2007 LIFT CONTROL SYSTEMS CATALOGUE 2007 All Your Needs For Elevators INDEX 1. Lift Control Cards... 3 2. Speed Control Units... 7 3. Emergency Rescue Cards... 8 4. Lift Control Panels... 10 5. Photocells...

More information

LIFT CONTROL SYSTEMS CATALOGUE 2009

LIFT CONTROL SYSTEMS CATALOGUE 2009 LIFT CONTROL SYSTEMS CATALOGUE 2009 All Your Needs For Elevators INDEX 1. Lift Control Cards... 3 2. Speed Control Units... 7 3. Emergency Rescue Cards... 8 4. Lift Control Panels... 10 5. Photocells...

More information

FLOOR INDICATORS CATALOGUE 2007

FLOOR INDICATORS CATALOGUE 2007 FLOOR CATALOGUE 2007 All Your Needs For Elevators INDEX 1. LCD Indicators... 3 2. Dot Matrix Indicators... 9 3. Accessories... 17 ALBEN İnşaat Makine Elektrik Elektronik San. ve Tic. Ltd. Şti 2/21 LCD

More information

FLOOR INDICATORS CATALOGUE

FLOOR INDICATORS CATALOGUE FLOOR CATALOGUE All Your Needs For Elevators INDEX 1. LCD Indicators... 3 2. Dot Matrix Indicators... 9 3. Accessories... 18 ALBEN İnşaat Makine Elektrik Elektronik San. ve Tic. Ltd. Şti 2/19 LCD LKG240128C

More information

FLOOR INDICATORS CATALOGUE 2007

FLOOR INDICATORS CATALOGUE 2007 FLOOR CATALOGUE 2007 All Your Needs For Elevators INDEX 1. LCD Indicators... 3 2. Dot Matrix Indicators... 9 3. Accessories... 17 ALBEN İnşaat Makine Elektrik Elektronik San. ve Tic. Ltd. Şti 2/21 LCD

More information

LCD240X128A Asansörler İçin Grafik LCD Gösterge Graphic LCD Display for Elevators

LCD240X128A Asansörler İçin Grafik LCD Gösterge Graphic LCD Display for Elevators LCD240X128A Asansörler İçin Grafik LCD Gösterge Graphic LCD Display for Elevators KULLANICI KILAVUZU USER MANUAL TR/EN TÜRKÇE ENGLISH Publisher ARKEL Elektrik Elektronik Ticaret Ltd. Şti. Date of issue

More information

GSM HOME SECURITY SYSTEM

GSM HOME SECURITY SYSTEM Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : GSM-120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5.

More information

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator

More information

RS Security Co., Ltd. RS Security Co., Ltd is specialized in physical access control turnstiles;

RS Security Co., Ltd. RS Security Co., Ltd is specialized in physical access control turnstiles; RS Security Co., Ltd Tel: 086755-28935596 Mobile: 08613480168583 www.szrssecurity.com Email: fiona@szrssecurity.com, Skype: Fiona_szrssecurity BB pin: 271f8b86 RS Security Co., Ltd is specialized in physical

More information

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS

More information

M1000 Process Alarm Monitor

M1000 Process Alarm Monitor Data Sheet Process Alarm Monitor Reliable Supervision and Control 10 inputs with LED indications Supports both NO/NC input contacts 10 open collector outputs Built-in siren relay Text label for alarm descriptions

More information

NX Series Inverters. HVAC Pocket Programming Guide

NX Series Inverters. HVAC Pocket Programming Guide NX Series Inverters HVAC Pocket Programming Guide HVAC Pocket Programming Guide HVAC Pocket Programming Guide / Contents This guide provides a single reference document for the user of NXL HVAC (product

More information

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation Galleon 6-10K Online UPS Voltronic Power Technology Corporation Features Galleon online UPS series delivers optimal power quality, provides superior power management, resolves utility power protection

More information

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS FLEET MANAGEMENT & CAR SECURITY SYSTEM FOR PROVIDERS AND CUSTOMERS The Tracker Server Communication Program for data collection The Tracker Client Map Program intended for dispatching desks The GSM/GPRS

More information

Memcom Emergency Telephone

Memcom Emergency Telephone Memcom Emergency Telephone Installation Guide Ref No. 450 900 (GB) Version 2 + + Simple wiring for quick installation + + Integrated LCD display shows you what you have programmed + + All code based programming

More information

How To Use A Pkn10 (Powerline) With A Microsd Card (Powerkit) On A Powerline (Powergen) Or Powerline 2 (Powerbee) (Powerbmi) (Pk10) (Operating

How To Use A Pkn10 (Powerline) With A Microsd Card (Powerkit) On A Powerline (Powergen) Or Powerline 2 (Powerbee) (Powerbmi) (Pk10) (Operating GB PKN10 serial node with colour LCD display User s manual Bač 49a, 6253 Knežak, SLOVENIA tel: ++ 386 5 753 2006 fax: ++ 386 5 753 2007 email: sec.electronics@siol.net http://www.secelectro.com SEC Electronics

More information

User s Manual Before using the inverter, you need to read and save the safety instructions.

User s Manual Before using the inverter, you need to read and save the safety instructions. User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information

More information

A1000 Cheat Sheet (Open Loop Vector)

A1000 Cheat Sheet (Open Loop Vector) A1000 Cheat Sheet (Open Loop Vector) The following procedure is a supplement to supplied with this equipment and will guide the user in properly wiring the A1000 and. It will also show the user how to

More information

Conventional Fire Detection and Extinguishant Control System Specification

Conventional Fire Detection and Extinguishant Control System Specification Conventional Fire Detection and Extinguishant Control System Specification Page 1 of 9 Scope Furnish a complete 24VDC Conventional, electrically supervised, combined fire detection and extinguishant release

More information

TMS TANK MANAGEMENT SYSTEM

TMS TANK MANAGEMENT SYSTEM TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS

More information

ELECTRONIC BOARDS - SUPRA

ELECTRONIC BOARDS - SUPRA ELECTRONIC BOARDS - SUPRA INDEX TROUBLESHOOTING BOARD SOURCE INTERCONNECTION C.E. INTERFACE PH INTERFACE HARD SWITCH RELAYS 32-OUTPUT CARD BOARD # 7520 # TROUBLESHOOTING BOARD 12V CONNECTIONS: CONNECTOR

More information

ABB Drives. User s Manual HTL Encoder Interface FEN-31

ABB Drives. User s Manual HTL Encoder Interface FEN-31 ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions

More information

Photovoltaic Solar Energy Unit EESFB

Photovoltaic Solar Energy Unit EESFB Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality

More information

AC-115 Compact Networked Single Door Controller. Installation and User Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.

More information

How to read this guide

How to read this guide How to read this guide The following shows the symbols used in this Quick start guide with descriptions and examples. Symbol Description Example P oint Reference Caution [ ] This symbol explains information

More information

VLT 6000 HVAC. Contents

VLT 6000 HVAC. Contents Contents Introduction Safety...3 Safety Guidelines...3 Warnings Against Unintended Start...3 Introduction...4 About this manual...4 Assumptions...4 References...4 Trademarks...5 Programming the VLT 6000

More information

4KVA/5KVA Parallel Installation Guide

4KVA/5KVA Parallel Installation Guide 4KVA/5KVA Parallel Installation Guide 1. Introduction This inverter can be used in parallel with two different operation modes. 1. Parallel operation in single phase with up to 4 units. The supported maximum

More information

SP 4K/5K Efecto & SP 5K Brilliant Parallel Installation Guide 1. Introduction

SP 4K/5K Efecto & SP 5K Brilliant Parallel Installation Guide 1. Introduction SP 4K/5K Efecto & SP 5K Brilliant Parallel Installation Guide 1. Introduction This inverter can be used in parallel with two different operation modes. 1. Parallel operation in single phase with up to

More information

DC-8706K Auto Dial Alarm System

DC-8706K Auto Dial Alarm System DC-8706K Auto Dial Alarm System User Guide Basic Contents: 1x the host unit; 1x wireless door (window) magnet; 1x wireless infrared detector; 2x remote control; 1x siren; 1x phone core; 1x AC to DC power

More information

Ticket Reader with real time clock and magnetic encoding

Ticket Reader with real time clock and magnetic encoding Ticket Reader with real time clock and magnetic encoding Order number: TL-31 The Ticket Reader TL 31 consists of the multifunctional MODPARK ticket modules integrated into a housing, which is well suited

More information

VLT AutomationDrive for Marine winch applications

VLT AutomationDrive for Marine winch applications MAKING MODERN LIVING POSSIBLE VLT APPLICATION NOTE VLT AutomationDrive for Marine winch applications This Application note is meant to be a guideline for using Danfoss VLT AutomationDrive in winch applications.

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

Automatic start of a generator

Automatic start of a generator Automatic start of a generator General description This application note will help you to set your Xtender for an automatic start of a generator as per different parameters such as the output power, the

More information

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111 , GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,

More information

Always on the Lookout Perfect Protection against Burglary

Always on the Lookout Perfect Protection against Burglary Always on the Lookout Perfect Protection against Burglary Terxon wired and hybrid alarm systems One system offers all possibilities Rely on experts With a qualified specialist installation contractor on

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

User and installation manual

User and installation manual User and installation manual aquaero 5 The information contained in this manual is subject to change without prior notice. All rights reserved. Current as of April 2011 ENGLISH: PAGE 1 DEUTSCH: SEITE 13

More information

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

TX GSM SMS Auto-dial Alarm System. Installation and User Manual TX GSM SMS Auto-dial Alarm System Installation and User Manual Product Features: 1. 16 wireless zones, 3 wired zones alarm system, suitable for small to medium size offices and homes. 2. The system uses

More information

S100. GSM House Alarm System. Http://www.GSMalarmsystem.com

S100. GSM House Alarm System. Http://www.GSMalarmsystem.com S100 GSM House Alarm System Http://www.GSMalarmsystem.com 1. Brief introduction The GSM Alarm System is a new security protection solution special for home, house and office and other applications. It

More information

LAND ROVER MANUAL CONTENTS APPLICATIONS GENERAL OPERATION SPECIAL FUNCTIONS REMOTE CONTROL PROGRAMMING

LAND ROVER MANUAL CONTENTS APPLICATIONS GENERAL OPERATION SPECIAL FUNCTIONS REMOTE CONTROL PROGRAMMING LAND ROVER LAND ROVER MANUAL CONTENTS APPLICATIONS GENERAL OPERATION SPECIAL FUNCTIONS REMOTE CONTROL PROGRAMMING APPLICATIONS VEHICLE SYSTEM YEAR CABLE CLASSIC RANGE ROVER 10AS 95 ON ADC110-B DEFENDER

More information

Multi-Protocol decoder 76 400

Multi-Protocol decoder 76 400 Multi-Protocol decoder 76 For locomotives with DC motors on digital layouts operating in the DCC- and Motorola data format. Features Regulated multi-protocol decoder for DCC and Motorola Suitable for DC

More information

Smart DeviceNet Remote I/O Terminals

Smart DeviceNet Remote I/O Terminals Smart DeviceNet Remote I/O Terminals ather and Use Information for Effective Preventive Maintenance et more useful data for preventive maintenance when you build cost-effective parallel information systems

More information

SMART SENSOR COLLECTION

SMART SENSOR COLLECTION TEMPERATURE SENSOR This sensor measures temperature in degrees Celsius or Fahrenheit. It works with all SensorHawk base units (SensorHawk-2, SensorHawk-8 and SensorHawk8/20) as well as the SecurityHawk-8

More information

Multi-Protocol decoder 76 200 with Load regulation

Multi-Protocol decoder 76 200 with Load regulation Multi-Protocol decoder 76 2 with Load regulation For locomotives with universal motors on digital layouts operating in the DCC and Motorola data format. Features 76 2 Load regulated multi-protocol decoder

More information

User manual LCD 240-2xx

User manual LCD 240-2xx Kapitelbezeichnung Kapitelbezeichnung X.X Unterpunkt User manual 2xx 2VS 2VP 2HS 2HSC 2HP 2HPC Kapitelbezeichnung Kapitelbezeichnung X.X Unterpunkt Memo SCHAEFER GmbH Winterlinger Str. 4 72488 Sigmaringen

More information

SDN INSTRUCTIONS 07/10, Ver 1.2. Somfy Digital Network (SDN) Installation and Programming

SDN INSTRUCTIONS 07/10, Ver 1.2. Somfy Digital Network (SDN) Installation and Programming Somfy Digital Network (SDN) Installation and Programming SSoomffyy SSyysst teemss IInncc.. 1 Table of Contents 1 General Information and Features... 3 1.1 ILT2 Motor... 3 1.2 SDN Switches... 4 1.3 ILT2

More information

TAKEDO -3VF V20 INSTRUCTION MANUAL. www.sms.bo.it 3 18-10-2013. REL. DATE T.M. Check and Approval

TAKEDO -3VF V20 INSTRUCTION MANUAL. www.sms.bo.it 3 18-10-2013. REL. DATE T.M. Check and Approval TAKEDO -3VF V20 INSTRUCTION MANUAL 3 18-10-2013 REL. DATE T.M. Check and Approval www.sms.bo.it PAGE INTENTIONALLY LEFT BLANK 1 INTRODUCTION TAKEDO-3VF V20 is a new type of drive with built-in EMC filter,

More information

ezsystem elab16m Project 1F: Alarm System (Full Project description)

ezsystem elab16m Project 1F: Alarm System (Full Project description) ezsystem elab16m Project 1F: Alarm System (Full Project description) ezsystem The aim of ezsystem is to enable Creativity and Innovation at an early age in a Problem Based Learning (PBL) approach. ezsystem

More information

RGK60 RGK50 RGAM10 RGAM20 RGAM4 Generator set control units

RGK60 RGK50 RGAM10 RGAM20 RGAM4 Generator set control units I123 GB 1207 RGK60 RGK50 RGAM10 RGAM20 RGAM4 Generator set control units CUSTOMIZATION SOFTWARE MANUAL List of contents Introduction... 2 Main window... 3 Device model selection... 3 Transmission of data

More information

How To Use A Power Supply Unit (Upu)

How To Use A Power Supply Unit (Upu) BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.

More information

ITEM DESCRIPTION SPECIFICATION TENDER OFFER

ITEM DESCRIPTION SPECIFICATION TENDER OFFER TECHNICAL SPECIFICATIONS PL1 & PL2 PLEASE TICK IF YOU COMPLY. SPECIFY YOUR OPTION IF YOU DON'T. ITEM DESCRIPTION SPECIFICATION TENDER OFFER Make (please specify) 1.0 Type Duplex Passenger Lift 2.0 Minimum

More information

Fire detection equipment

Fire detection equipment PRODUCT CATALOG Fire detection equipment www.apollo-fire.com Apollo Fire Detectors is one of the world s largest manufacturers of fire detectors, modules and notification devices. Established in 1980,

More information

GPD 506/P5 Start-up Procedure and Checklist

GPD 506/P5 Start-up Procedure and Checklist GPD 506/P5 Start-up Procedure and Checklist Preparation for GPD506/P5 Drive Start-Up...2 HVAC Start-Up Procedure for GPD 506/P5 WITH Bypass Option:...4 HVAC Start-Up Procedure for GPD 506/P5 WITHOUT Bypass

More information

Plena Voice Alarm System. Software Manual Configuration Software

Plena Voice Alarm System. Software Manual Configuration Software Plena Voice Alarm System en Software Manual Configuration Software Plena Voice Alarm System Software Manual Table of Contents en 3 Table of Contents Table of Contents...3 1. Introduction...7 1.1 Purpose...7

More information

WITURA CORPORATION SDN BHD

WITURA CORPORATION SDN BHD WT 1010SA Stand Alone GSM Alarm System User Manual and Installation Instructions Version: 1.2 Updated: 4 JAN 2012 WITURA CORPORATION SDN BHD Stand Alone GSM Alarm System Instruction Manual 1 Introduction:

More information

Electronic Power Control

Electronic Power Control Service. Self-Study Programme 210 Electronic Power Control Design and Function With the Electronic Power Control system, the throttle valve is actuated only by an electric motor. This eliminates the need

More information

NXL Series Inverters. HVAC Inverters made simple

NXL Series Inverters. HVAC Inverters made simple NXL Series Inverters HVAC Inverters made simple Honeywell s Voice Of the Customer process unveils a range of requirements expressed by specifiers and installers, that are ideally covered by the NXL inverter

More information

Modern Robotics, Inc Core Device Discovery Utility. Modern Robotics Inc, 2015

Modern Robotics, Inc Core Device Discovery Utility. Modern Robotics Inc, 2015 Modern Robotics, Inc Core Device Discovery Utility Modern Robotics Inc, 2015 Version 1.0.1 October 27, 2015 Core Device Discovery Application Guide The Core Device Discovery utility allows you to retrieve

More information

SNMP Web Management. User s Manual For SNMP Web Card/Box

SNMP Web Management. User s Manual For SNMP Web Card/Box SNMP Web Management User s Manual For SNMP Web Card/Box Management Software for Off-Grid Inverter Version: 1.2 Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2 Features... 1 1.3 Overlook...

More information

EKON BMS HVAC system. Simply Smart. www.ekonhome.com. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch

EKON BMS HVAC system. Simply Smart. www.ekonhome.com. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch Going green EKON BMS HVAC system Wireless Thermostat with Light Switch Control Fan Coil or Central AirCon Wireless Touch Screen Controller Wireless Light or Motorized Blind Wall Switch www.ekonhome.com

More information

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS USER MANUAL USER MANUAL ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS INTRODUCTION The (HA-841K) is a complete

More information

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification 08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and

More information

INTELLIGENT BUILDINGS BUS SYSTEMS, MyHOME. Ján Cigánek, Martin Janáček, Stanislav Števo

INTELLIGENT BUILDINGS BUS SYSTEMS, MyHOME. Ján Cigánek, Martin Janáček, Stanislav Števo INTELLIGENT BUILDINGS BUS SYSTEMS, MyHOME Ján Cigánek, Martin Janáček, Stanislav Števo Slovak University of Technology Ilkovičova 3, 812 19 Bratislava, Slovak Republic Tel.: +421 2 60291111 Fax: +421 2

More information

If an occupancy of room is zero, i.e. room is empty then light source will be switched off automatically

If an occupancy of room is zero, i.e. room is empty then light source will be switched off automatically EE389 Electronic Design Lab Project Report, EE Dept, IIT Bombay, Nov 2009 Fully-automated control of lighting and security system of a Room Group No: D2 Bharat Bhushan (06d04026) Sravan

More information

Wires & Connections Component Circuit Symbol Function of Component. Power Supplies Component Circuit Symbol Function of Component

Wires & Connections Component Circuit Symbol Function of Component. Power Supplies Component Circuit Symbol Function of Component Lista Dei Simboli Dei Circuiti Per i Componenti Elettronici Wires & Connections Wire Wires joined Wires not joined To pass current very easily from one part of a circuit to another. A 'blob' should be

More information

Combi B Alarm box. Mounting instructions

Combi B Alarm box. Mounting instructions Combi B Alarm box Mounting instructions EN Mounting instructions Alarm box Combi B VdS, G113064, G113065, G113066 Table of Contents 1 Description... 3 2 System overview... 3 3 Structure... 3 3.1 Power

More information

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB , GH Q631 0076 R0111 2CDC 071 240 F0003 The Shutter Actuator Standard is used to control a maximum of four independent 230 VAC drives for positioning shutters, blinds, awnings and other hangings as well

More information

GSM ALARM SYSTEM USER MANUAL

GSM ALARM SYSTEM USER MANUAL GSM ALARM SYSTEM USER MANUAL 1. Instruction The alarm system is based on GSM network. With a GSM SIM card, it can be used wherever you want and no need to connect any wire, which is convenient and easy

More information

GPS & GSM BASED REAL-TIME VEHICLE TRACKING SYSTEM.

GPS & GSM BASED REAL-TIME VEHICLE TRACKING SYSTEM. GPS & GSM BASED REAL-TIME VEHICLE TRACKING SYSTEM. Introduction: The Proposed design is cost-effective, reliable and has the function of accurate tracking. When large object or vehicles were spread out

More information

PowerGem Pro Uninterruptible Power Supply

PowerGem Pro Uninterruptible Power Supply Uninterruptible Power Supply User-friendly Intelligent Ultra reliable Range The Most Intelligent On-Line Double Conversion Power Protection System The range achieves higher reliability and greater immunity

More information

STERILIZERS, LABORATORY DRYING OVENS

STERILIZERS, LABORATORY DRYING OVENS TS9026 TS9053 TS9135 TS9430 TS 9000 SERIES: STERILIZERS, LABORATORY DRYING OVENS Series TS9000 consists of four different cabinets available in sizes from 26 litres to 430 litres. Interior housing and

More information

Match. GE Digital Energy. Uninterruptible Power Supply 500-1500 VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Match. GE Digital Energy. Uninterruptible Power Supply 500-1500 VA. Technology for the Digital World. Match UPS. GE Digital Energy. Match Uninterruptible Power Supply 500-1500 VA Manufactured by: General Electric Company Telephone +41 (0)91 / 850 51 51 CH 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44 Switzerland Website www.gedigitalenergy.com

More information

EDI Distributor Control Interface Wiring and Setup Instructions

EDI Distributor Control Interface Wiring and Setup Instructions Universal I/O EDI Distributor Control Interface Wiring and Setup Instructions EDI UNIVERSAL I/O INTERFACE MODULE The only interface needed for EDI-V5 controls Network compatible with all older EDI controls

More information

IDS X-Series User Manual 700-398-01D Issued July 2012

IDS X-Series User Manual 700-398-01D Issued July 2012 1 2 Contents 1. Introduction to the IDS X-Series Panels... 7 2. Before Operating Your Alarm System... 7 3. Understanding the Keypad LEDs... 8 3.1 Viewing Data on an LED Keypad... 12 3.1.1 LED Status Indicators...

More information

Driver Pant 8 and antenna switcher Ant 8. User manual

Driver Pant 8 and antenna switcher Ant 8. User manual Driver Pant 8 and antenna switcher Ant 8 User manual Table of contents Table of contents... 2 Introduction... 3 Shipping Contents... 3 Technical Data... 3 Control Panel... 4 Rear panel... 5 Controller

More information

Integrated Building Management and Security System. Building Automation & Security. www.coba-group.com

Integrated Building Management and Security System. Building Automation & Security. www.coba-group.com Integrated Building Management and Security System Building Automation & Security www.coba-group.com INTEGRATED BUILDING MANAGEMENT AND SECURITY SYSTEM INDEX 1 GENERAL... 3 1.1 SYSTEM INTEGRATION... 3

More information

Instruction book IQAN-MDM. Publ. no. HY17-8328/UK Edition June, 2007

Instruction book IQAN-MDM. Publ. no. HY17-8328/UK Edition June, 2007 Instruction book IQAN-MDM Publ. no. HY17-8328/UK Edition June, 2007 Contents 1 Introduction...............................................................3 Safety symbols................................................................

More information

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.

More information

ODYSSEY. Security System Owner s Manual. Kit No. 08E51-SHJ-100 08E55-SHJ-100. 2004 American Honda Motor Co., Inc. - All Rights Reserved.

ODYSSEY. Security System Owner s Manual. Kit No. 08E51-SHJ-100 08E55-SHJ-100. 2004 American Honda Motor Co., Inc. - All Rights Reserved. Kit No. 08E5-SHJ-00 08E55-SHJ-00 Security System Owner s Manual ODYSSEY 004 American Honda Motor Co., Inc. - All Rights Reserved. Contents Introduction... 3 Emergency Disarming During the Panic Alarm Activation...

More information

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual EDA-Z5008 & Z5020 Radio Fire Alarm System User Manual Electro-Detectors Ltd. Electro House, Edinburgh Way Harlow, Essex, CM20 2EG UK Tel: 01279 635668. Fax 01279 450185 Email: eda@electrodetectors.co.uk

More information

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273

More information

Alliance System Ordering Guide

Alliance System Ordering Guide Alliance System Ordering Guide Multiple Technologies Versatile Hardware Powerful Software One family of parts and accessories Version 12-Nov-03 Alliance System Ordering Guide Table of Contents Controllers

More information

SECTION 13850 DETECTION AND ALARM

SECTION 13850 DETECTION AND ALARM SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring

More information

User Manual WatchPower

User Manual WatchPower User Manual WatchPower Management Software for Inverter Table of Contents 1. WatchPower Overview... 1 1.1. Introduction... 1 1.2. Features... 1 2. WatchPower Install and Uninstall... 1 2.1. System Requirement...

More information

User Manual Software for DSL Digital Speed Switch

User Manual Software for DSL Digital Speed Switch User Manual Software for DSL Digital Speed Switch Software version from 1.0.1 Baumer Hübner GmbH Max-Dohrn-Str. 2+4 D-10589 Berlin Phone +49 (0)30 690 03-0 Fax +49 (0)30 690 03-104 info@baumerhuebner.com

More information

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire) FEATURES & APPLICATIONS Inexpensive 2 wire to 3 wire start controller for electric start high speed gas generators. Optimized for use with Outback Invertors. Supports three types of 3 wire generator control

More information

User s Manual. Management Software for Inverter

User s Manual. Management Software for Inverter WatchPower User s Manual Management Software for Inverter Table of Contents 1. WatchPower Overview... 2 1.1. Introduction... 2 1.2. Features... 2 2. WatchPower Install and Uninstall... 2 2.1. System Requirement...

More information

Frequently Asked Questions for TFT Remote Controlled Monitors. First Rev 4/6/2005 SGMc Second Rev 5/7/2005 Third Rev 11/15/2005

Frequently Asked Questions for TFT Remote Controlled Monitors. First Rev 4/6/2005 SGMc Second Rev 5/7/2005 Third Rev 11/15/2005 Frequently Asked Questions for TFT Remote Controlled Monitors. First Rev 4/6/2005 SGMc Second Rev 5/7/2005 Third Rev 11/15/2005 1. What was the primary spark that started the fire under TFT to make remote

More information

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp

More information

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s. 16043 CHIAVARI (GE) Tel. +39 0185 318444 - Fax +39 0185 472835 mailto: len@len.it url: http//www.len.

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s. 16043 CHIAVARI (GE) Tel. +39 0185 318444 - Fax +39 0185 472835 mailto: len@len.it url: http//www.len. MA511 General Index 1 INTRODUCTION... 3 1.1 HARDWARE FEATURES:... 4 2 INTERFACE... 5 2.1 KEYBOARD... 6 2.2 POWER ON... 7 2.3 POWER OFF... 7 2.4 DETECTOR CONNECTION... 7 2.5 DETECTOR SUBSTITUTION...7 3

More information

Access Control Using Smartcard And Passcode

Access Control Using Smartcard And Passcode IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-issn: 2278-1676 Volume 4, Issue 5 (Jan. - Feb. 2013), PP 29-34 Access Control Using Smartcard And Passcode Omorogiuwa Eseosa 1., Uhunmwangho

More information

CONFIGURABLE SAFETY RELAYS

CONFIGURABLE SAFETY RELAYS MSI-m/R, MSI-mx/Rx Configurable MSI Safety Relay with function for efficient material flow in a packaging application Special features Sequential or Parallel with automatic mode detection MSI-mx for separate

More information

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012 Technical Information THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012 GENERAL DESCRIPTION THYRISTORS T1-1PH is a full digital and universal

More information

Using your LED Plus keypad

Using your LED Plus keypad Using your LED Plus keypad System 238 System 2316 System 238i System 2316i Part Number 5-051-372-00 Rev B Thank you for purchasing this C&K alarm system Your system is one of the most powerful and advanced

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

1 4. 3 4-2 ABNORMAL OPERATION. 4-2-1 Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target

1 4. 3 4-2 ABNORMAL OPERATION. 4-2-1 Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target 4-2 ABNORMAL OPERATI 4-2-1 An is represented by 3 digit characters. The first 2 digit means the subsection, and the last 1 digit means the specifics. Ex.) Indoor unit Network communication Error Subsection

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way

More information

30-120 3 Phase Modular Finally the benefits of Modular ups are for all

30-120 3 Phase Modular Finally the benefits of Modular ups are for all MUST 30-120 3 Phase Modular UPS Finally the benefits of Modular ups are for all MUST 30-120 MUST means Modular UPS System Three-phase MUST 30-120 is an uninterruptible power supply with double conversion

More information

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL Rev. D PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL 10 BORIGHT AVENUE, KENILWORTH NEW JERSEY 07033 TELEPHONE: 800-524-0273 FAX: 908-686-9317 TABLE OF CONTENTS Page

More information