Product and Application Description



Similar documents
Product and functional description

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Inwall 4 Input / 4 Output Module

Transmitter Actuator 230V wave UP 560. Operation

How To Use A Power Supply On A Powerline 2.2 (Ai)

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted xx, xx, xx

Inwall Room Temperature Unit

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Drayton Digistat +2RF/+3RF

Flush-mount room temperature sensor AQR2531ANW.

RRV934. Multi-controller. Synco living

Operating instructions. RCD flat 4-fold, 6-fold

Light scene push button 8gang comfort flush-mounted xx

HERZ-Thermal Actuators

Room Temperature Sensors

ABB i-bus KNX Fan Coil Controller FC/S 1.1

HCR3.2/.. Chipcard reader HOTEL SOLUTION

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

IntesisBox KNX LG Air Conditioning

Unica for KNX system 226

Installation Guide. DEVIreg 530. Electronic Thermostat.

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Heating Controller. Building Technologies HVAC Products

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

Niko Home Control. Installation Manual

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

DALI RC BASIC SO. Control unit Operating instructions

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

Operating Instructions. Room temperature controller

Cross-beam scanning system to detect slim objects. 100 mm in

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

Flush-mounted room thermostats

HCE80/HCC80/HCE80R/HCC80R

TMS TANK MANAGEMENT SYSTEM

Digital input modules

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation.

Glass sensor 2gang with room thermostat Glass sensor 3gang with room thermostat

Push button 3gang standard flush-mounted xx

ACS-30-EU-EMDR-10-MOD

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Operating instructions II / 2004

T5000 T000 LCD Digital Fan Coil Thermostat

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

ABB i-bus KNX Security Solutions with KNX Security Terminal Product Information

Adjustable room thermostat for heating only or cooling only systems

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

Temperature controller for heated/chilled ceiling systems

Thermostat with display

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

Installation & User Manual Radio Remote rev1.0.3

For installation guide see reverse of book

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Introduction. Page 2 / 9

Universal control module for motorized devices

MOUNTING AND OPERATING INSTRUCTIONS

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

User Manual THR840DUK Digital Thermostat

ELECTRIC CENTRAL HEATING FLOW BOILER

T0118 T2118 T3118. Instruction Manual

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

KNX Panasonic Air Conditioners

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

Operating instructions IV / 2007

Installation Instructions. Thermo Call TC3

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Busch-Watchdog Presence EIB Type:

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

EIB/KNX IP Interface with Power over Ethernet (PoE)

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

KNX Interface. User Manual PM00A00IRI

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

IntesisBox KNX Mitsubishi Heavy Industries AC

Shunt lock function 3066

Model UT713 OPERATING MANUAL

Passive Infrared Motion Detector 5420/90. Installation Instructions

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

CR24-.. Single room controllers

Smile. The All-In-One Heating Controller

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

VIESMANN. Installation and service instructions VITOTROL 100. for contractors

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Electronic Control Devices The European Product Catalogue 2007

ABB i-bus KNX Security Terminals MT/U , MT/S M and M Product Manual

WIRELESS STATUS MONITOR

RY2 miniature industrial relays

Transcription:

Technical Product - Information Product and Application Description The room temperature controller UP 237K and UP 252K are available in the following colors, matching the design of the wall switch design line DELTA i-system or DELTA style: DELTA i-system Temperature Controller UP 237K titanium white aluminum metallic DELTA style Temperature Controller titanium white/ metallic silver platinum metallic 5WG1 237-2KB11 5WG1 237-2KB31 5WG1 254-2KB13 5WG1 254-2KB43 The room temperature controls UP 237K and are especially designed for usage in rooms which are heated and/or cooled and whose temperatures are controlled depending on up to four room operating modes (comfort mode, pre-comfort mode, energy-savings mode and protection mode). As required, a parameter can be used to set that the controller does not consider all four operating modes but rather only three (comfort mode, energy-savings mode and protection mode). The room temperature control can be used a a two-point control (thermostat) or as a continuous control (P or PI control). These Room temperature controller can only function together with the necessary Bus Transceiver Module (BTM) UP 117 and the associated application program. LED displays Along with a button and a rotary knob on its upper edge, the clear and self-explanatory user interface contains 5 green illuminating light emitting diodes (LED) to display whether "manual operation" is activated as well as the current room operating mode and two red illuminating LEDs and 2 duo-color illuminating LEDs on the left edge. The duo-color LEDs are used to display whether the heating valve (LED is lit in red) or the cooling valve (LED is lit in yellow) is open. If these LEDs are not illuminated, then both valves are closed. A red LED is used to display whether a window is open or whether a dew point alarm is pending. Button Briefly pressing the button on the control causes switching in automatic mode (the LED for the display of manual operation is not lit) each time between "comfort mode" and "pre-comfort mode" (with four operating modes) or between "comfort mode" and "energy-savings mode" (with three operating modes). Moreover briefly pressing the button during active energy-savings or protection mode starts a "comfort prolongation". Pressing and holding down (e.g.> 1 s, but < 3 s) the button during continuous comfort prolongation can cause this to end at any time and jump back to the room operating mode before the start of the comfort prolongation. Holding down the button for a longer time (> 3 s) can cause switching from automatic to manual operation. In manual operation every room operating mode can be permanently activated and not changed by a bus telegram. If manual operation is activated, then each time the button is pressed briefly the light display of the current operating mode wanders gradually from the current position to the next operating mode symbol until the extreme right or left position is reached and from there back again. If during a waiting time of around 3 seconds no renewed brief pressing of the button occurs, then the displayed room operating mode will be activated and this reported by the Bus. If the button in "manual operation" is pressed for a very long (> 3 s) time, then the system will be switched to automatic operation and at the same time to comfort mode. If a presence detector is installed, then a brief pressing of the button in automatic operation is ignored. Rotary knob The control is supplied with two rotary knobs: one inserted in the control for shifting the basic target value to a higher or lower value and a second for directly setting the target value in the range of 16 to 26 C. If instead of shifting the target value with the adjustable shifting range, direct target value setting in degrees Celsius is desired, then the inserted rotary knob should be exchanged with the delivered rotary knob and the parameter "target value setting" should be switched to "directly in C" in the "Functions / objects" parameter window. Commissioning For commissioning a control with the help of ETS (Engineering Tool Software), the control together with the suitable DELTA frame must first be inserted into a Bus Transceiver Module (BTM) UP 117 which serves to supply power to the control and to transmit data via the KNX Bus. After removing the rotary knob for target value shifting, the recess for the commissioning button and the commissioning LED of the control are visible. Siemens AG UP 237K,, 5 pages Technical-Manual 2.8.2.8/1

Technical Product-Information Note: The bus transceiver module UP 117 and the associated DELTA frame are not supplied and must be ordered separately. With the help of ETS, the application program can be selected, the specific parameter and addresses assigned and transferred into the room temperature controls UP 237K and. Application program The "0705 CO Room Temperature Control H+K 803001" application program supports the following functions: Switching between automatic / manual operation and switching the room operating mode with the button, Target value shifting or target value setting in C with the rotary knob, Status display with LEDs: - Displays (green) for manual operation and the current room operating mode (comfort, pre-comfort, energy-savings and protection mode), - Displays (red/yellow), whether the heating or cooling valve is open, - Displays (red) for dew point alarm and open window. Room temperature control, adjustable as: - heating only, cooling only, heating and cooling, each selectable as - heating with two-point control, - heating with PI control, - heating with PI control and sequence control (e.g. with floor and radiator heating), - cooling with two-point control, - cooling with PI control, - cooling with PI control and sequence control. (e.g. with cooling ceiling and supply air cooler). The following partial functions are part of room temperature control: - Room temperature measurement using the internal temperature sensor with Offset setting, - Room temperature measurement using an external temperature sensor with Offset setting, - Computation of current room temperature actual value (internal and external sensors weighted), - With target value shifting: Basic target value assignment via parameter setting and/or via Bus, - With target value shifting: Computation of current room temperature target value from basic target value and shifting, - time-restricted removal of night sinking or the protection mode (comfort prolongation), - with presence detection via the Bus, switching to the "comfort" operating mode occurs, - Dew point mode can be activated via the Bus, - Evaluation of the window conditions via the Bus, - Frost protection / heat protection are reported via the Bus, - PI control for heating / cooling with constant regulating variable-output (in %) or toggling regulating variables-output (on / off). - Separated or joint regulating variable output for heating and cooling, - Separated regulating variable output for basic level and auxiliary level for 2-level heating or cooling, - Switching the desired effect and scaling the regulating variable for heating/cooling is possible, - Maximal and minimal regulating variable for heating/cooling possible, - Operating condition (control status) can be read out via the Bus, Technical Data Power supply via the flush-mounted bus transceiver module UP 117 Operating elements 1 rotary button for manual adjustment of the setpoint (control range and type of adjustment dependent on the parameter setting and type of rotary button) 1 button for toggling of the room operating mode and vice versa Display elements 5 green LED`s for the current operating mode (comfort, pre-comfort, energy-saving, protection mode) and for manual mode 2 red LED`s for dew point alarm and open window 2 red/yellow LED`s for Heating / cooling mode Temperature measurement Measuring range: 0... + 40 C Resolution: 0.08 K Accuracy of the sensor temperature: ± 1.0 K under reference conditions, ± 2.0 K under ambient conditions and in measuring range Connections 10-pole plug-in connector for connection with the bus transceiver module UP 117 Mechanical data Casing: plastic Dimensions: - Temperature controller UP 237K for DELTA i- system (L x W x D): 55 x 55 x 16 mm (without spring) - Temperature controller for DELTA style (L x W x D): 68 x 68 x 20 mm (without spring) Weight: approx. 30 g (UP 237K) Weight: approx. 40 g () Technical-Manual UP 237K,, 5 pages Siemens AG Update: http://www.siemens.com/gamma Siemens AG 2012 Control Products and Systems Subject to change without further notice. P. O. Box 10 09 53, D-93009 Regensburg 2.8.2.8/2

Technical Product Information Fire load: 730 KJ ± 10 % Mounting: The operator panel is attached to the BTM UP 117 and screwed to its mounting frame. Electrical safety Degree of pollution (according to IEC 60664-1): 2 Type of protection (according to EN 60529): IP 20 Protection class (according to IEC 61140): III Overvoltage categorie (according to IEC 60664-1): III Bus: Safety extra-low voltage SELV DC 24V Device complies with EN 50090-2-2 Reliability Failure rate: 214 fit at 40 C EMV requirements Complies with EN 61000-6-1 and 50090-2-2 Environmental conditions Climatic withstand capability: EN 50090-2-2 Ambient operating temperature: - 5... + 45 C Storage temperature: - 25... + 70 C Relative humidity (not condensing): 5 % up to 93 % Markings KNX EIB CE mark In accordance with the EMV guideline (residential and functional buildings), low voltage guideline Location and function of the operating and display elements A1 A2 A3 A4 A5 A4 LED green: illuminates during energy-saving mode A5 LED green: lights up continuously in protection mode, blinks slowly in permanent protection mode A6: Pushbutton for selection of room operating mode A7: LED red: illuminates with dew point alarm A8: LED yellow: illuminates if cooling valve is open A9: LED red: illuminates if heating valve is open A10: LED red: illuminates if open window A11: Rotary button for manual setpoint shifting (shifting range dependent on parameter setting) or for setpoint adjustment in C Mounting, wiring and commissioning General description The temperature controller is attached with the associated DELTA frame to the BTM UP 117 and screwed to its mounting frame. Mounting and commissioning (see figure 2) - Attach the bus cable and fix the BTM UP 117 (B8) on the flush socket (see mounting instructions for BTM UP 117) - Remove rotary knob (B1 or B2) from the temperature controller (B3) - Attach temperature controller with DELTA frame (B4) to the BTM UP 117 and secure using screw (B5) - Press programming button (B7): programming LED (B6) illuminates - Load physical address and the configures application program by means of the ETS - Replace rotary knob (B1 or B2). B8 B7 A6 A7 A8 A9 A10 A11 B2 B1 B4 B3 B6 B5 figure 1: Location of the operating and display elements A1 LED green: illuminates during manual mode A2 LED green: lights up continuously in comfort mode and blinks slowly in comfort prolongation. A3 LED green: illuminates during pre-comfort mode figure 2: Mounting controller B1 Rotary button for setpoint shifting B2 Rotary button for setpoint adjustment in C B3 Temperature controller heating / cooling B4 DELTA frame Siemens AG UP 237K,, 5 pages Technical-Manual 2.8.2.8/3

Technical Product-Information B5 Screw for securing the controller to the mounting frame of the UP 117 (anti-theft protection) B6 LED for displaying normal mode (LED Off) or address mode (LED On); it is automatically extinguished once the physical address has been transferred B7 Button for toggling between normal mode/addressing mode for transferring the physical address B8 Bus Transceiver Module UP 117 The air draft of windows and doors have to be avoided! Installation instructions The device can be used for fixed installations, in dry interior spaces and for integration into a flush socket. V WARNING The device must be mounted and commissioned by an authorised electrician. The device may not be inserted in the same box as 230 V devices. The device may be mounted in switch and socket combinations if VDE-certified devices are used exclusively. The prevailing safety rules must be heeded. The device may not be opened. For planning and construction of electric installations, the relevant guidelines, regulations and standards of the respective country are to be considered. Mounting location (see figure 3) Observe the following points when mounting the controller: Controller mounted on interior wall of room to be conditioned, vis-á-vis the heat source: At ca. 1.5 m height in the room and at least 50 cm from the next wall. Not on outside walls. Not in niches or behind curtains. Not above or near heat sources or shelves. Not on walls covering heat sources such as a chimney. Not in the radiation range of heat sources and lighting bodies e.g. spotlights. Not in areas exposed to direct solar radiation. figure 3: Installation references for sensors and temperature controller. Seal the end of the installation conduit to prevent false measurements due to air drafts, see figure 4. figure 4: Sealing installation conduit Dismantling (see figure 2) - Remove rotary knob (B1 or B2) - Loosen screw (B5) - Remove controller together with DELTA frame. - Remove BTM UP 117 (B8) according to dismantling instructions. Technical-Manual UP 237K,, 5 pages Siemens AG Update: http://www.siemens.com/gamma Siemens AG 2012 Control Products and Systems Subject to change without further notice. P. O. Box 10 09 53, D-93009 Regensburg 2.8.2.8/4

Technical Product Information Dimension Drawing DELTA i-system temperature controller UP 237K Dimensions in mm 55 55 16 DELTA style temperature controller Dimensions in mm 68 68 20 General Notes The operating instructions must be handed over to the client. Any faulty device is to be sent together with a return delivery note of the local Siemens office. If you have further questions concerning the product please contact our technical support. Siemens AG UP 237K,, 5 pages Technical-Manual 2.8.2.8/5