Temperature controller for heated/chilled ceiling systems
|
|
|
- Ezra Bradley
- 10 years ago
- Views:
Transcription
1 Product information Temperature controller for heated/chilled ceiling systems Table of contents Overview of the system 2 Brief description, Accessories 3 Technical data sheet Technical data 5 Safety notes 5 Product features 6 Configuration 6 Electrical installation 6 Operation 7 Functions Introduction 9 Function overview 9 Setpoint determination 10 Pre-comfort 11 Energy hold off (EHO) 11 Chilled ceiling with dew point monitoring 12 External setpoint shift 12 External temperature sensor (ai1) 13 Analogue outputs 13 Dimensions, installation, commissioning, service Dimensions [mm] 15 Mechanical installation 15 Electrical installation 15 Design for supply / wire sizing 16 Commissioning / Power On response 16 Test and simulation mode 16 Internal Function test 17 Simulation control sequence 17 S4- en v subject to changes 1 / 20
2 Overview of the system Single room controller Heated/chilled ceiling applications 6-way ball valve and rotary actuators EXT-K3B LR24A-MP / LR24A-SR Accessories Diagnostic and setting device ZTH-GEN Setting for MP / MFT(2) actuators PC-Tool ZK1-VAV Connection cable ZTH-VAV to CRK24, Diagnostic socket 1/2 2 / 20 S4- en v subject to changes
3 Brief description, Accessories Brief description The room temperature controller is precisely designed for the regulation of heated / chilled ceilings. The output sequence of the controller is calibrated to the new 6-way ball valve EXT-K3B with LR24A-MP / LR24A-SR actuator. This controller should therefore only be utilised in the actuator in combination with the 6-way ball valve. The multitude of override features makes possible an economically and energetically optimised system solution for individualised control of the room climate. Device Standard model with user interface (setpoint adjustment, mode switch and status display). For operation, see page 7. Accessories Mechanical accessories Type Description CRZA-A CRZW Spare cover without user interface Spare baseplate S4- en v subject to changes 3 / 20
4 4 / 20 S4- en v subject to changes
5 Technical data sheet Temperature controller for single-room applications with one analogue output: The 6-way ball valve for the regulation of a heated/chilled ceiling can be connected with the analogue output ao1. Technical data Safety notes Electrical data Nominal Voltage AC 24 V 50/60 Hz Dimensioning 3 VA, without actuators Power supply range AC V Connections Terminal block 1 3: 2.5 mm 2 Terminal block 4 8: 1.5 mm 2 Functional data Control characteristics P P-band heating / cooling Selectable: 2.0 K / 1.0 K or 4.0 K / 2.0 K External temperature sensor (ai1) Type NTC, 5 k, Power supply range C e.g. Belimo Type TFK Setpoint Adjustment range C (Default 21 C) Energy hold off (EHO) Pre-comfort Heating 15 C / Cooling 40 C Heating 3 K / Cooling +3 K Dead band 1 K Frost protection limit 10 C Operation Mode switch and status display (LED) AUTO (green) ECO (orange) MAX (red) Rotary knob for setpoint adjustment ±3 K Communication connection for field devices 2 x PP (for PC-Tool, ZTH-GEN, etc.) Inputs Output 2 x analogue, 2 x digital External temperature sensor (ai1) Type NTC, 5 k, Power supply range C External setpoint shift (ai2) 0 10 V correspond to: 0 10 K Digital inputs (di1, di2,) Contact rating 10 ma 1x analogue 6-way ball valve (ao1) (0) 2 10 V, max. 5 ma Norms and Standards Protection class III Safety extra-low voltage Degree of protection IP30 (EN 60529) Mode of operation Type 1 (EN ) Software class A (EN ) EMC CE according to 2004/108/EU Ambient conditions Operation C / 20 90% r.h. (non-condensating) Transport and storage C / 20 90% r.h. (non-condensating) Dimensions / Weight Dimensions (H x W x D) 99 x 84 x 32 mm Weight 105 g Housing colour Baseplate NCS2005-R80B light grey (corresponds approximately to RAL 7035) Cover RAL9003 signal white! The controller is not allowed to be used outside the specified field of application, especially in aircraft or in any other airborne means of transport. It may only be installed by suitably trained personnel. Any legal regulations or regulations issued by government agency authorities must be observed during assembly. The device does not contain any parts that can be replaced or repaired by the user. The device contains electrical and electronic components and is not allowed to be disposed of as household refuse. All locally valid regulations and requirements must be observed. S4- en v subject to changes 5 / 20
6 Technical data sheet Product features Energy hold off (EHO) Pre-comfort Frost Dew point limitation In energy saving mode, the room temperature is regulated to the building protection level, i.e. the heating setpoint is significantly reduced or the cooling setpoint is significantly increased, for instance in a room with an open window. The room temperature is reduced to stand-by level, i.e. the heating setpoint is slightly reduced and/or the cooling setpoint is slightly increased, for instance in a room that is temporarily unoccupied. If the current room temperature falls below 10 C, then the frost function will be activated. If the optional connectable dew point limiter responds, then the valve is moved into neutral position. External temperature sensor External setpoint shift An external temperature sensor can be connected at analogue input ai1. An external DC V signal at the analogue input ai2 can be used to shift the basic setpoint by K, e.g. for summer/winter compensation. The functions are described in detail on pages 9 to 13. Configuration Configuration ao1 modulating ao1 On/Off ao1 [V] ao1 [V] ON OFF ao1 l (heating) 7.3 ao1 (heating) l DIP Default settings 1 P-Band normal P-Band wide 2 Output ao1 modulating Output ao1 On/Off ao1 (cooling) [%] 6 2 ao1 (cooling) [%]. Electrical installation Wiring diagram Notes Connect via safety isolation transformer.! Parallel connection of other actuators possible. Note the performance data. AC 24 V ~ External NTC temperature sensor 0 10 V Shifting Pre-comfort EHO Dew point limiter ao1 U5 1 U5 2 ai1/di1 di2 ai y U ~ Actuator for 6-way valve Inputs Outputs 3 ai1 External temperature sensor 6 ao1 System output for 6-way valve di1 Pre-comfort Other connections 4 di2 Energy hold off / dew point 7 PP1 Diagnostic socket 1 5 ai2 External setpoint shift 6 / 20 S4- en v subject to changes
7 Operation Operating level 1 Operation Operating mode / Setpoint Rotary knob for setpoint adjustment Potentiometer ±3 K Status display MAX (red) ECO (orange) AUTO (green) Mode switch MAX ECO AUTO Mode switch and status display Selection can be made between three operating modes: AUTO optimum comfort mode The room will be kept at comfort zone status insofar as the external control signals permit this. All control functions are enabled. ECO optimum energy mode The room will be kept at pre-comfort status insofar as the external control signals permit this. Reduced heating ( 3 K) and elevated cooling setpoints (+3 K) are in effect in this status. Starting from this status, the room can be returned to comfort status within a short time. Sequence control is enabled. The operating mode ECO is intended for rooms not continuously occupied and/or for reduced requirements. MAX Boost function The room will be heated or cooled at maximum power, insofar as the external control signals permit this. The Boost function is switched off: Timer off Setpoint is reached Selection of a different mode (AUTO or ECO) Operating level 2 Configuration DIP switch for configuration Order-Nr. CR24-B2xxxxx ON OFF W H 36 Basic setpoint setting Application / Parameters DIP switch for configuration DIP switches 1 and 2 Basic setpoint setting W H (heating setpoint) Potentiometer C (Default 21 C) Label for settings Recording the settings used (DIP switch and basic setpoint) U5/ 2 U5/ 1 Label for settings Operating level 3 Service Test / Simulation Measuring point terminals Measuring points for all connection terminals (also during operation). Measuring point terminals Internal function test A comprehensive internal function test can be started with the mode switch which makes it possible to check the controller, including nominal voltage (AC 24V). The three LEDs (status display) are used thereby to display the voltage level and the statuses. Simulation control sequence The rotary knob for the setpoint adjustment can be used to simulate the connected actuators, and thus the heating and cooling control sequences, independent of the room temperature. Rotary knob for simulation of control sequence Internal function test ZTH-GEN / PC-Tool connection ZTH-GEN / PC-Tool connection The diagnostic socket 1 is used for PP communications with the connected Belimo MFT actuator. Physical access to the valve actuator can be dispensed with as a result. S4- en v subject to changes 7 / 20
8 8 / 20 S4- en v subject to changes
9 Functions Introduction The control functions of the define the behaviour of the controller output or influence the current setpoint, respectively. Operation can be automated and comfort and energy savings potential enhanced through the utilisation of corresponding sensor mechanisms at the input side. The corresponding functions are described in detail in the following. Function overview Supply Application Operation Inputs Output Functions Installation AC 24 V / 50/60 Hz Room temperature controller in the comfort zone Internal temperature sensor (Type NTC, Power supply range C) Setpoint (adjustment range C) Mode selection switch: AUTO ECO MAX Mode display LED: AUTO ECO MAX Setpoint adjustment rotary knob ±3 K Pre-comfort Dew point limitation Energy hold off (EHO) External temperature sensor (Type NTC 5 kω, Power supply range C) External setpoint shift 0 10 V 2 10 V System output: Belimo 6-way ball valve Control characteristics: P P-Band, switchable Output can be switched (modulating / On/Off) Room temperature monitoring (frost) Internal Function test with nominal voltage check Commissioning mode with simulation of output and sequence Diagnostics via integrated PC-Tool connection Surface mounting with flush-mounted or surface-mounted connection Application documentation Continually expanded, comprehensive documentation with specific applications is available for the controller. S4- en v subject to changes 9 / 20
10 Functions Setpoint calculation Valve opening [%] 100 Pre-comfort EHO 0 Frost Dew point W A current setpoint t Room [ C] Dead band W H Basic setpoint W s Setpoint shift 0 10 V Setpoint adjustment ±3 K Operating status Heating setpoint Cooling setpoint Comfort Pre-comfort Basic setpoint W H ±3 K setpoint adjustment + Setpoint shift 0 10 V Comfort-Heating setpoint W A 3 K Pre-comfort-Offset heating Comfort-Heating setpoint W A +1 K dead band Comfort-Heating setpoint W A +1 K dead band +3 K Pre-comfort-Offset cooling Energy hold off fix 15 C (building protection) fix 40 C (building protection) Frost fix 10 C without function Examples Comfort Pre-comfort Y Y 3 K Pre-comfort-Offset Heating +3 K Pre-comfort-Offset Cooling t R +1 K dead band t R +1 K dead band 23 C Comfort setpoint W A 23 C Comfort setpoint W A 10 / 20 S4- en v subject to changes
11 Functions Pre-comfort Digital input di1 AC 24 V ~ NTC If a local detector (e.g. a motion detector) has an effect on the digital input di1 and closes the corresponding contact, then the room will be regulated to stand-by level, i.e. the heating setpoint is reduced by 3 K or the cooling setpoint is raised by 3K, respectively. Typical applications [%] Y Pre-comfort 3 ai/di1 Pre-comfort One motion detector, light switch or other detector at di1 reduces the energy consumption in unoccupied rooms. Superordinate imperative command, e.g. GLT. Notes The frost limit is monitored with the internal sensor during Pre-comfort when an external temperature sensor is used. As a result of the automatic sensor recognition feature, the switch-over to Pre-comfort takes approximately 40 seconds. Legend 0 W A t Room [ C] Y W A Output signal Current setpoint Energy Hold Off (EHO) Digital input di2 AC 24 V ~ 1 2 Energy Hold Off 4 di2 If a local detector (e.g. a window switch) has an effect on the digital input di2 and closes the corresponding contact, then the room will be regulated in energy-savings mode to the building protection level, i.e. the heating setpoint is significantly reduced (15 C) and/or the cooling setpoint is significantly raised (40 C), so that sensitive furnishings (plants, pictures, etc.) will not be able to suffer any damage. Typical applications One window switch at di2 stops energy consumption as soon as the window is opened until the lower or upper building protection limit has been reached. Superordinate imperative command, e.g. GLT. [%] 100 Y EHO Notes The 6-way valve is moved into neutral position during the Energy Hold Off (ao1 = 6 V). The mode switch (operating level 1) is deactivated during the Energy Hold Off (the input di2 has higher priority). 0 t Room [ C] W A Legend Y Output signal W A Current setpoint S4- en v subject to changes 11 / 20
12 Functions Chilled ceiling with dew point limiter AC 24 V ~ Dew point Cooling / Heating Dew point reached Digital input di2 If the optional connectable dew point limiter responds, then the output ao1 is overridden to 6 V by means of the input di2 (external dew point limiter). The 6-way ball valve moves into neutral position. Typical applications Chilled ceiling systems in which one dew point limit is required ao1 U5 1 di Y U5 ~ Belimo actuator for 6-way valve ao1 [V] 10 ao1 (heating) l 7.3 Dew point ao1 (cooling) [%]. External setpoint shift Analogue input ai2 AC 24 V ~ Setpoint shift 0 10 V An external DC V signal at the analogue input ai2 can be used to raise the basic setpoint by K (corresponding to 0 10 V). Typical application Summer/Winter Compensation 5 ai2 1 2 W [ C] S [V] Legend W Setpoint S Shift signal Notes A negative shift is possible by setting the basic setpoint to the desired final setpoint, e.g. from 21 C (default value) to 16 C. This results in the following correspondences: 0 5 V: C and 5 10 V: C (see illustration at the left). 12 / 20 S4- en v subject to changes
13 Functions External temperature sensor (ai1) An external NTC temperature sensor can be connected at analogue input ai1. Sensor type: NTC 5k (5 kω), e.g. Belimo TFK. Typical applications More flexible placement of the sensor for recording the room temperature Temperature measurement in the ventilation channel for recording the average room temperature. Notes The controller recognises it automatically if an external sensor is connected. No additional adjustments are required. The simultaneous utilisation of Pre-comfort at di1 is possible, although in this case a switchover to the internal sensor is made (see also «Pre-comfort»). As a result, the current room temperature is monitored for building protection. AC 24 V T ~ External NTC temperature sensor Pre-comfort 3 ai/di1 1 2 Analogue outputs LR24A-MP Actuator for 6-way ball valve System output «ao1» (Terminal 6). diagnostic socket «U5/1» (Terminal 7). AC 24 V ~ Note When using an LR24A-MP, it is expedient to direct the communications signal U5 of the actuator to the controller. Interventions can be implemented on the actuator by means of controller diagnostic socket 1 without the need for direct physical access. ao1 U5 1 U ai1/di1 di2 ai y U ~ LR24A-MP Actuator for 6-way valve S4- en v subject to changes 13 / 20
14 14 / 20 S4- en v subject to changes
15 Dimensions, installation, commissioning, service Dimensions [mm] Mechanical installation 1. Remove the housing cover. 2. Pull out slightly the wall of the housing to release the pcb. 3. Remove the PCB. Rotary knob for setpoint adjustment If the rotary knob has been removed proceed as follows: a. Insert the rotary knob approximately half way and turn it clockwise as far as the stop. b. Remove the knob and align it so that the cam is flush with the left stop (see left). c. Insert the knob fully Left stop Cam Electrical installation Flush-mounted connection Surface-mounted connection 2.5mm 2 AC 24V mm Terminal connection S4- en v subject to changes 15 / 20
16 Dimensions, installation, commissioning, service Power supply design / wire sizing In addition to the actual wire sizing, attention must also be paid to the surrounding area and the cable routing. Signal cables must not be laid in the vicinity of load cables, objects liable to cause EMC interference. etc. Paired or layer stranded cables improve immunity to interference. 24 V supply Wire sizing and cabling Analogue input connection ai1 The wire sizing and installation of the AC 24 V supply, the fuse protection, and the cables are dependent on the total operated load and local regulations. Account must be taken of the following performance data, including starting currents: Wire sizing values for room temperature controllers: 3 VA per Wire sizing values for the valve actuators can be obtained from current data sheets and product information ( Other devices to be operated with the AC 24 V supply Reserve capacity for subsequent expansion (if planned) The analogue input ai1 is used to connect an external NTC 5 kω temperature sensor. The sensor value is 5969 Ω at 21 C. A change of 50 Ω corresponds to approximately 0.2 K in this range. The sensor cable constitutes a series resistance that must be added to the actual sensor value. Assuming a cable length of 15 m (2 x 15 = 30 m), the resistance of one 0.75 mm 2 Cu cable is approximately 0.7 Ω, in other words negligible. To prevent interference, however, the sensor cable should be a maximum of 20 m long. Commissioning / Power on behaviour Commissioning 1. Assemble the baseplate of the housing and connect the cables (see page 15) 2. Configure the DIP switches on the printed circuit board according to the required application. 3. Assemble the printed circuit board on the baseplate of the housing and then mount the housing cover (see page 15) 4. Switch on the nominal voltage AC 24 V 5. Optional: start the test and simulation mode (see below) When the voltage is applied, the system starts operating normally in AUTO mode unless the test simulation mode is selected. The active operating status is determined primarily by the configuration of the DIP switches and the status of the inputs. Power on behaviour After power on of the voltage supply the output gets initialised as follows: ao1 = 0 V Subsequently the controller switches automatically to the control mode. Test and simulation mode All controllers are supplied with two auxiliary programs for commissioning and servicing: Internal function test Control sequence simulation Activating test and simulation mode Deactivating test and simulation mode The test and simulation mode of controllers can be activated easily with the mode switch on the operator panel. To activate test mode 1. Set the mode switch to MAX The red LED (MAX status indication) lights up 2. Keep the mode switch pressed for ten seconds The internal function test is activated (see below) To activate simulation mode 3. Press the mode switch again briefly for approx. one second The green LED (COMF status indication) flashes Control sequence simulation is activated (see below) The test and simulation mode can be deactivated either by pressing the mode switch again for ten seconds or by interrupting the power supply. It is also deactivated automatically 15 minutes after the last user action (auto-reset). 16 / 20 S4- en v subject to changes
17 Dimensions, installation, commissioning, service Internal function test The internal function test tests the nominal voltage that is connected to the controller (AC 24 V), in other words the complete electrical wiring system from the control cabinet to the controller.. The three LEDs (status indication) indicate the voltage level (see below) and states during the test. Note Case B and C do not need further attention. In case A (<20 V) attention must be paid to the following points: Quality of the wiring and connections Cable length and diameter and the transformer sizing Nominal voltage (AC 24 V) LED (status indication) Scenario A Scenario B Scenario C MAX red flash flash permanently on ECO orange flash flash permanently on AUTO green permanently off flash permanently on <20 V V >22 V Control sequence simulation In the simulation mode, the connected actuator can be operated regardless of the room temperature. This permits the function of the system to be checked. Cooling W = X +1 Heating Notes The external control signals (di1 and di2) are suppressed during the simulation. The potentiometer may be adjusted only slowly, due to the system-dependent attenuation of the setpoint potentiometer in simulation mode. Simulation mode is automatically deactivated 15 minutes after the last user action (auto-reset). Output [V] XpK XpH out Potentiometer (setpoint adjustment) Shift S4- en v subject to changes 17 / 20
18 18 / 20 S4- en v subject to changes
19
20 All-inclusive. 5 year guarantee World-wide on your doorstep Complete product range froma single source Tested quality Short delivery time Comprehensive support Switzerland Germany Austria Slovakia BELIMO Automation AG Sales Switzerland Brunnenbachstrasse 1 CH-8340 Hinwil Tel. +41 (0) Fax +41 (0) [email protected] Benelux BELIMO Servomotoren BV BENELUX Postbus 300, NL-8160 AH Epe Radeweg 25, NL-8171 MD Vaassen Tel. +31 (0) Fax +31 (0) [email protected] BELIMO Stellantriebe Vertriebs GmbH Welfenstrasse 27 D Stuttgart Tel. +49 (0) Fax +49 (0) [email protected] At no charge Orders: Tel Technical Consultation: Tel Fax Personal consultation with Regional Sales Director in: Berlin, Hanover, Düsseldorf Leipzig, Frankfurt, Munich Hamburg, Stuttgart BELIMO Automation Handelsgesellschaft m.b.h. Geiselbergstrasse A-1110 Vienna, Austria Tel. +43 (0) Fax +43 (0) [email protected] Austria West Tel. +43 (0) Fax +43 (0) [email protected] Hungary Tel. +36 (06)20/ Fax +36 (06)23/ [email protected] Tel. +43 (0) Fax +43 (0) [email protected] Slovenia/Croatia/Bosnia Tel (0) Fax +386-(0) [email protected] Serbia/Montenegro/ Macedonia/Bosnia Tel./Fax +381-(0) [email protected] Belimo worldwide:
CRK24-B1 Heated/chilled ceiling system
CRK4-B1 CRK4-B1 Heated/chilled ceiling system Table of contents Principle 3 Night switch-off: Regulating the 6-way valve with Energy Hold Off (EHO) 4 All options: 6-way valve regulation with pre-comfort,
CR24-.. Single room controllers
Product information CR4- CR4- Single room controllers Table of contents wwwbelimocom Overview of the system Overview of functions 3 Technical data sheets CR4-B1 / CR4-A1 Single room controllers CR4-B /
Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet NV24A--RE Communicative globe valve actuator for 2-way and 3-way globe valves Actuating force 1000 N Nominal voltage AC/DC 24 V Control Modulating DC (0)2...10 V Variable Nominal stroke
Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC 100... 240 V Control: Open/close or 3-point Auxiliary switch
echnical data sheet Rotary actuator LR-S Rotary actuator for and -way (control) ball valves orque 5 Nm Nominal voltage C... 4 V Control: Open/close or -point uxiliary switch echnical data Electrical data
Belimo Gateway MP to Modbus RTU - UK24MOD
Product information UK24MOD MODBUS RTU Belimo Gateway MP to Modbus RTU - UK24MOD Contents Complete overview 2 Technical data 3 Safety notes 4 Product features 4 Installation and commissioning 4 Electrical
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Product and Application Description
Technical Product - Information Product and Application Description The room temperature controller UP 237K and UP 252K are available in the following colors, matching the design of the wall switch design
RRV934. Multi-controller. Synco living
s 2 709 Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way
Heating Controller. Building Technologies HVAC Products
2 474 Heating Controller RVP300 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones with or
VAV system solution for non-pressure-dependent applications in enclosed spaces
System information VAV-Universal VAV system solution for non-pressure-dependent applications in enclosed spaces able of contents echnical data sheet Brief description 3 echnical data 4 Safety notes 5 Dimensions
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
RVL470. Heating Controller. Building Technologies HVAC Products. Series B
2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use
s 5 146 Synco 200 Signal Converter SEZ220 With preprogrammed standard applications Freely programmable enu-driven operation Use The signal converter is for use in HVAC plant to provide minimum / maximum
Electric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems
3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
Air damper actuators
4 634 OpenAir TM Air damper actuators GDB...1 GLB...1 Rotary version, / AC 230 V Electronic motor driven actuators for three-position and modulating control Nominal torque 5 Nm (GDB), 10 Nm (GLB) Mechanically
Flush-mounted room thermostats
s 3 076 RDF300, RDF300.02, RDF340 RDF400.01 RDF600 RDF600 Flush-mounted room thermostats for 2-pipe, 2-pipe with el. heater and 4-pipe fan coil units for use with compressors in DX type equipment RDF300
Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB
, GH Q631 0076 R0111 2CDC 071 240 F0003 The Shutter Actuator Standard is used to control a maximum of four independent 230 VAC drives for positioning shutters, blinds, awnings and other hangings as well
ABB i-bus KNX Fan Coil Controller FC/S 1.1
Product manual ABB i-bus KNX Fan Coil Controller FC/S 1.1 Intelligent Installation Systems Contents Page 1 Introduction... 2 2 Device technology... 3 3 Application and planning 3.1 Heating, ventilation
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
225-230T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators
Actuators Technical data sheet 225-230T-05-S2 Rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor 5
Electronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
How To Use A Power Supply On A Powerline 2.2 (Ai)
KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang
Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111
, GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,
ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1
Product Manual ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Intelligent Installation Systems Contents Page 1 Introduction.......................................
Application Sheet Fan coil unit with staged fan, heating/cooling coil (2 pipe) on analog output
Heating with LHW and cooling with CHW changeover Modulating control of heating and cooling valve (2 pipe) on analog Automatic or manual 3-speed fan control Room temperature and fan speed operation via
HCR3.2/.. Chipcard reader HOTEL SOLUTION
s 6 332 HOTEL SOLUTION Chipcard reader HCR3.2/.. Chipcard reader for hotel room access control Reads access code on chipcard Transfers access code to room controller Built-in optical display of messages
basicdim DGC Compact control module
luxctrol lighting control sstem DGC Compact control module Product description Compact dimensions for luminaire installation For up to 0 DSI or LI ballasts ( per output channel) LI IN input LI/DSI output
Inwall Room Temperature Unit
Inwall Room Temperature Unit TM11B01KNX TM11B11KNX TM11B21KNX Product Handbook Product: Inwall Room Temperature Unit Order Code: TM11B01KNX TM11B11KNX TM11B21KNX Application Program ETS: TM11B_1KNX Inwall
ACS-30-EU-EMDR-10-MOD
Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature
SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program
Preface Contents SIMATIC NET CP 243-2 AS-Interface Master Manual Technical Description and Installation Instructions Interface to the User Program 2 in the S7-200 CPU Access to the Data of the AS-i Slaves
DALI RC BASIC SO. Control unit Operating instructions
DALI RC BASIC SO Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Function 5 Light control 5 Brightness
DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.
1100 & 1400 Energy Controllers Satchwell 1100 & 1400 for energy-efficient temperature control in smaller buildings. 02 1100 & 1400 Energy Controllers Features he 1100 and 1400 Energy Controllers are self-configuring
HCE80/HCC80/HCE80R/HCC80R
HCE80/HCC80/HCE80R/HCC80R UNDERFLOOR HEATING-ZONEING CONTROLLERS PRODUCT DATA FEATURES Easy and fast installation because the new wiring design Pluggable terminals for fast wiring connection because clamp
Inwall 4 Input / 4 Output Module
Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators
Actuators Technical data sheet 225C-024T-05 Continuous control rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations.
HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function
Specifications Supply Voltage 240VAC @ 0.07Amps or 24VAC @ 0.380Amps Relays 240V @ 12A max (resistive) / Comp1,2,3, Aux Ht, Rv O/B) Fuses (Equipment) 15 Amps Maximum 3AG Control Range Minus 10 to 50C Control
Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
MINI MCR-SL-R-UI(-SP)
Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts
Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese.
Page 1 of 6 Application Proportional 0-10V or 3-position modulating or On/ Off control of Frese OPTIMA Compact valves in heating, ventilating and air conditioning systems. The actuator can be mounted on
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TECHNICAL DATA CARATTERISTICHE MECCANICHE Housing Self-extinguishing plastic, UL 94 V0 Dimensions 48x48 mm DIN depth 98 mm Weight 225 g approx.
Combi switchbox with integrated 3/2 way pilot valve
H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled
Controls for fan coil units and cassettes
Controls for fan coil units and cassettes Selection of controls for use with fan coil & cassette units. Stand alone, selection guide Control unit Motor Standard QZAZ-04-10 QZAZ-04-20 QZAZ-04-75 QZAZ-05-11
Actuator for modulating control AME 435
Data sheet Actuator for modulating control AME 435 Description The actuator automatically adapts its stroke to the valve end positions which reduces commissioning time (self stroking). The advanced design
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN
Power Supply and Indicator Unit Type 5024-1 Fig. 1 Type 5024-1 Mounting and Operating Instructions EB 9539 EN Edition October 2003 Application 1 Application The Type 5024-1 Power Supply and Indicator Unit
T5000 T000 LCD Digital Fan Coil Thermostat
T5000 T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostats are designed to control heating, cooling, or year round air conditioning unit in Commercial,
Installation Instructions. Thermo Call TC3
Installation Instructions Thermo Call TC3 1 2 # 24990A 965 082 AMP 3 4 # 98393A # 67769A sw Improper installation or repair of Webasto heating and cooling systems can cause fire or the leakage of deadly
CO2 Alarm. Operation. Application
CO Alarm 100-77V AC Supply Voltage Two pre-configured alarm and control thresholds Thresholds factory set to customer requirements on dispersive infrared sensing technology Optional internal audible alarm
Power consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point 0...95
Actuators Technical data sheet 227S-230-05-S1 Rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor 5
KNX Gateway RGK02-5023E-01
KNX Gateway RGK02-5023E-01 Table of contents Page 1 General Information 1.1 Technical data 5 1.2. Intended Use 6 1.3 Specifications 6 1.4 Compatibility 6 1.5 Scope of delivery 6 2 Information about the
Operating instructions IV / 2007
General Operating instructions IV / 2007 Contents General Installation Application and function Application and function... 2 Safety information... 2 Design and dimensions... 3 Wiring diagram... 3 Installation
Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596
Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596 Product overview The Tracer ZN517 controller is a field-installed, application-specific controller that provides directdigital
Electrical connection
(I)GSU 14B Ultrasonic Label Fork Dimensioned drawing Part No. 501 09234 4mm 12-30 V DC 4 m/s Ultrasonic forked sensor for universal application Large mouth width, hence also suitable for booklets or fan-fold
Laser diffuse reflection light scanner with background suppression. Dimensioned drawing
Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049
WD-AMX Water Detection Controllers
Page 1 of 5 WD-AMX Water Detection Controllers Features: Benefit: LED Status of leak status VFC output Audible alarm Auto or manual reset alarm output Uses an isolated AC signal which prevents oxidation
SYSTEM 45. C R H Electronics Design
SYSTEM 45 C R H Electronics Design SYSTEM 45 All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, & A outputs. Independent 25
Operating instructions II / 2004
Operating instructions II / 2004 Light and presence sensor TOUCH DIM LS/PD LI OSRAM GmbH Costumer-Service-Center (CSC) Steinerne Furt 62 86167 Augsburg, Germany www.osram.com www.osram.de Tel. : (+49)
T7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital
Proportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions
Compact presence detector Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause
KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184
EN KNX TH65-AP Thermo-Hygrometer Technical specifications and installation instructions Item number 70184 Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
Smile. The All-In-One Heating Controller
Smile EVERYTHING UNDER CONTROL The All-In-One Heating Controller Versatile, energy-efficient heating control. The All-In-One Heating Controller Smile controllers are ideal to gain maximum efficiency from
0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
Installation Instructions. ThermoCall TC4. Entry/Advanced
Installation Instructions ThermoCall TC4 Entry/Advanced Thermo Call TC4 1 2 # 24990A 965 082 AMP 3 4 # 98393A # 67769A Thermo Call TC4 5 ThermoCall TC4 Entry 1 2 3 4 5 6 7 8 9 10 11 12 sw Please refer
B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted 7566359x, 7566459x, 7566559x
B.IQ push button 3-5gang with room Product name: Design: ETS search path: B.IQ push button 3-, 4-, 5gang with room thermostat and display V2 Flush-mounted Push button / B.IQ / B.IQ push button xgang with
DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions
DAI DIM/COVERTER COTRO (DC V) 1 10V (0-10 V) analog DAI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions Dim-and Switch Functions: The DAI Dim/Converter Control DC V is suitable
PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version 2.1.0 (2013-11-15)
PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN User Manual Document version 2.1.0 (2013-11-15) Products taken into account Product Name Model Part number PCAN-B10011S IPEH-002041 CANopen
Electronic Power Control
Service. Self-Study Programme 210 Electronic Power Control Design and Function With the Electronic Power Control system, the throttle valve is actuated only by an electric motor. This eliminates the need
Technical Description. Transistor D.C. Chopper Controller Type GS 24 S
Technical Description Transistor D.C. Chopper Controller Type GS 24 S Table of contents 1. Getting started guide 2. General information 2.1. Characteristics 2.2. Accessories 3. Information about the Machine
Multi-Range Programmable DC Power Supplies 9115 Series
Data Sheet 1200 W Multi-Range DC Power Supplies Features & Benefits Any 9115 series model can replace several supplies on your bench or in your rack. Unlike conventional supplies with fixed output ratings,
ZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8
ZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8 Quick Start A This device is a Z-Wave Actuator. Triple click one of the buttons on the device will include the device.
(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently
(68.52) X June 2000 Supercedes February 2000 xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM.... we look @ business differently XENEX SYSTEM ARCHITECTURE Note: This schematic is for guidance only please
ABB Drives. User s Manual HTL Encoder Interface FEN-31
ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions
Fire Alarm Control Panel. Family. Operating Manual
Fire Alarm Control Panel Family Operating Manual CONTENTS System Description AH-03312 System Characteristics... Fire Signal Receiving Board Description-4L... Fire Signal Receiving Board Description-8L...
TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C
Installation TURN OFF POWER TO THE SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Installation should be carried out by an electrician or a qualified technician. 1.1 Find a Location for the
ALARMLINE ANALOGUE Linear Heat Detection System
ALARMLINE ANALOGUE Alarmline Analogue sensor cable senses temperature variations by continuously monitoring the resistance of specially doped N.T.C. polymeric insulation. A change in temperature produces
For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.
s For UK only RX39.1 and the applications package SP-03 are sold in the United Kingdom only. 3 876 3876P01 RX Room controller Communicating controllers for fan-coil applications SP-03 RX39.1 The RX39.1
MasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
SYSTEM 4C. C R H Electronics Design
SYSTEM 4C C R H Electronics Design SYSTEM 4C All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, A outputs. Independent 25
Characterised control valve (CCV) with adjustable flow rate and sensoroperated flow control, and power and energy-monitoring function
Belimo Energy Valve TM web server manual P6..W..EV-BAC Characterised control valve (CCV) with adjustable flow rate and sensoroperated flow control, and power and energy-monitoring function Contents General
User Manual THR840DUK Digital Thermostat
User Manual THR840DUK Digital Thermostat 50051982-001 Rev. A WARNING: This product must be correctly installed and configured to work properly (see pages 12-24). If you are not experienced in wiring electrical
Thermostat with display
H/LN4691-0 674 59-64170 Thermostat with display RA00118AA_I-01PC-13W39 www.homesystems-legrandgroup.com Thermostat with display Contents Thermostat with display 1 Introduction 4 1.1 Warnings and recommendations
T7079A,B Solid State Remote Temperature Controllers
T7079A,B Solid State Remote Temperature Controllers FEATURES PRODUCT DATA Switch selection of heat or cool mode. Temperature sensing up to 400 feet. Does not require field calibration. 0K NTC temperature
is then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS
Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an
Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner
Quick Stepper 3G ECP Positioner Versions Mechanical feed-back Pneumatic Remote feed-back Local display, Pneumatic Remote feed-back Local display, Electric / Hydraulic Remote feed-back Electric / Hydraulic
93.68/93.69. Time scale: from 0.1s to 6h Multi-function For use with 34.51 (EMR) and 34.81 (SSR) relays. Screw terminal and push-in terminal
Series - Timed socket for 34 series Features.68/.69 Slim timed sockets for 34 series, 6.2 mm wide Timer adjustment via top mounted rotary knob accessible after assembly Control signal terminal DIP-switch
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: 5204183. www.guentner.de. Data sheet GIOD.1 V_3.0
Data sheet GIOD.1 Input/output module with CAN bus ERP no.: 5204183 www.guentner.de Page 2 / 10 Contents 1 GIOD.1... 3 1.1 Functional description...3 1.2 Connections... 5 1.3 Electrical properties of...
ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011
, 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.
