FM 4473 TEST REPORT. Rendered to: VTECH INDUSTRIES, LLP. SERIES/MODEL: 4 x 4 CMC Hurricane PRODUCT TYPE: Skylight



Similar documents
ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: Atrium Companies, Inc. SERIES/MODEL: 50/305 HS PRODUCT TYPE: Vinyl Horizontal Slider

ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT. Rendered to: BEKAERT SPECIALTY FILMS, LLC

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

How To Test For An Architectural Test

ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: NORSE, INC.

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Report No.: B Rendered to: CAPTIVEAIRE, INC. Blue Bell, Pennsylvania

PERFORMANCE TEST REPORT. Rendered to: UNITED STATES ALUMINUM CORPORATION. SERIES/MODEL: 450 Center Glaze PRODUCT TYPE: Aluminum Curtain Wall

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

BLOWING DUST INFILTRATION TEST REPORT. Rendered to: TEX-STAR WINDOWS, INC. PROJECT: Blowing Dust Test SERIES: 3000 Horizontal Sliding Window

PERFORMANCE TEST REPORT. Rendered to: TREMCO INCORPORATED. SERIES/MODEL: Proglaze ETA PRODUCT TYPE: Engineered Transition Assembly

BLOWING DUST INFILTRATION TEST REPORT. Rendered to: TEX-STAR WINDOWS, INC. PROJECT: Blowing Dust Test SERIES: 3000 Double Hung Window

TEST REPORT. Report No.: B Rendered to: CROFT, LLC. Magnolia, Mississippi. PRODUCT TYPE: Aluminum Single Hung Window SERIES/MODEL: 95

AST M F /GSA TS01 T EST R EPO R T. Rendered to: UNI T E D ST A T ES A L U M INU M

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Report No.: B Rendered to: AMERICAN PRODUCTS, INC Tampa, Florida

PERFORMANCE TEST REPORT. Rendered to: BAMCO INC. PRODUCT TYPE: ACM Wall Panel Systems

PERFORMANCE TEST REPORT. Rendered to: ARCHITECTURAL METAL SOLUTIONS, INC.

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: EAGLE WINDOW & DOOR COMPANY

UL 580 TEST REPORT. Rendered to: ARMSTRONG WORLD INDUSTRIES. SERIES/MODEL: MW Vector PRODUCT TYPE: Ceiling System, 3' OC

TEST REPORT. Report No.: A Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept

TEST REPORT. Rendered to: INTERNATIONAL WINDOW Hayward, California. PRODUCT TYPE: Aluminum Hopper SERIES/MODEL: 7222

TEST REPORT. Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: CR LAURENCE CO., INC. SERIES/MODEL: 7500 Concealed Vent TYPE: Projecting (Awning)

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: TUBELITE, INC. SERIES/MODEL: T TYPE: Two-Lite Storefront

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: MGM INDUSTRIES SERIES/MODEL: TYPE: Single Hung Window

TEST REPORT. Rendered to: INTEX MILLWORK SOLUTIONS, LLC. For: Rigid Cellular PVC Guardrail System Hampton RS40

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: TREX COMPANY, LLC. Series/Model: Trex Seclusion

TEST REPORT. Rendered to: DEXERDRY. For: Deck Weatherproofing System Installed with AZEK Deck Boards

PERFORMANCE TEST REPORT. Rendered to: PROGRESSIVE FOAM TECHNOLOGIES, INC PRODUCT: EPS FOAM

MOCK-UP TEST REPORT. Rendered to: TUBELITE, INC. PROJECT: 200 Series Curtain Wall Mock-Up

PERFORMANCE EVALUATION TEST REPORT. Rendered to: HANDI-SHIM, LLC. SERIES/MODEL: Handi-Shim 1/32", 1/16", 1/8" and 1/4" PRODUCT: Plastic Shims

TEST REPORT. Rendered to: BRISTOLITE SKYLIGHTS Santa Ana, California

PERFORMANCE TEST REPORT. Rendered to: FIBERLOCK TECHNOLOGIES, INC.

TEST REPORT. Rendered to: LMT-Mercer Group, Inc. For: PRODUCT: 4" x 4" and 5" x 5" PVC Porch Posts with Aluminum Reinforcing

PERFORMANCE TEST REPORT. Rendered to: FORMTECH ENTERPRISES, INC. SERIES/MODEL: Truline PRODUCT TYPE: PVC Seawall

TEST REPORT. Rendered to: HOMELAND VINYL PRODUCTS, INC. For:

SOUND TRANSMISSION CLASS TEST REPORT Series/Model: VL-WDW11 VistaLuxe Awning

Clad Direct Glaze Window Installation Instructions

TEST REPORT. Rendered to: FAIRWAY BUILDING PRODUCTS, LP. For: LandMarke Railing System. PVC Guardrail System "Patent Number 7,487,941"

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

CHAPTER 7: Building Systems ROOFING SYSTEMS

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual

SOUND TRANSMISSION CLASS TEST REPORT Series/Model: T-DR1 Teutonic Outswing Vinyl Entrance Door

SOUND TRANSMISSION CLASS TEST REPORT Series/Model: T-DR2 Teutonic Outswing Vinyl Entrance Door

Building Code Clarifications - 7. Fire Resistance

Assessing Curtain Walls

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

INSTALLATION OF A BAY WINDOW

Metal Roofing Practical Design

Important Information for Installer & Homeowner

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

SERIES 238 WINDOWS. NOTE: Read instructions completely before attempting any installation.

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

SECTION SERIES 1500 VINYL PATIO DOORS

CLEAR-DIVISIONS CENTERFOLD

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

PHP SYSTEMS/DESIGN Course Number AIAPHP202 Provider Number J490 Applications in Sustainable Technology for Supporting Rooftop Piping and Equipment

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN Phone (260) Sales Fax (260)

Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls and Sloped Glazing Systems

REPORT NUMBER: COQ-003 ORIGINAL ISSUE DATE: July 19, 2013

CLEAR-DIVISIONS VARIOFOLD

ATI Evaluation Service A Division of Architectural Testing Certification Services

FIELD TESTING SERVICES

Casement/Awning Window Parts Reference Catalog

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

March 14, Installation of Bay, Bow and Garden Windows

Electrical Wiring Technical Bulletin

Owner's Manual & Assembly Instructions

AMERICAN GOTHIC PLAYHOUSE

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Impact-Resistant Windows and Sliding Glass Doors

GYPSUM AREA SEPARATION FIREWALLS GA

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

CITIZENS PROPERTY INSURANCE CORPORATION. STREET ADDRESS: Gulf Blvd, Maderia Beach, FL Six story masonry residence

Window Glass Design 5 According to ASTM E 1300

Barewood Octagon and Elongated Windows Installation Instructions

Sprinkler Identification Numbers

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

H-Stud Area Separation Wall System

Light Architecture. Colors Sweden. Light

Superform Products Ltd.

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

Scottsdale, Arizona. Presentation by: Hermes Norero, P.E. President and CEO

Open Up Your Space, Add Light Series 2050 and Series 2050i Garden Windows

Table of Contents PART 1 WINDOW SELECTION GUIDE. Window and Door Selection Guide

CLEAR-DIVISIONS APERTO

Insulation R-Value Comparisons

Facility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components

Best Barns USA Assembly Book

Miami-Dade Qualified Drainable Blade Louvered Penthouse

) and air spaces (R a

CF-Mesa, CF-Light Mesa, CF-Flute, CF-Metl-Plank, CF-Striated, CF-Santa Fe, CF-Architectural Flat, CF...

WINDOW PANNING AND TRIMS

How to Lock Out Crime: Home Security Windows

Harness Your Energy NOW AVAILABLE! the new. ASW-58A-22/30 Solar Thermal Collector

A0 SHEET 1 OF LOCUST STREET FRANKFORT, KANSAS FRANKFORT, KANSAS ROOF REPAIR OF THE 400 LOCUST STREET

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

Transcription:

FM 4473 TEST REPORT Rendered to: VTECH INDUSTRIES, LLP SERIES/MODEL: 4 x 4 CMC Hurricane PRODUCT TYPE: Skylight Report No.: 92240.01-801-75 Test Date: 08/27/09 Report Date: 08/31/09 Expiration Date: 08/27/13 2865 Market Loop Southlake, Texas 76092 phone: 817-410-7202 fax: 817-424-8463 www.archtest.com

FM 4473 TEST REPORT Rendered to: VTECH INDUSTRIES, LLP 5534 Harvey Wilson Drive Houston, Texas 77020 Report No.: 92240.01-801-75 Test Dates: 08/27/09 Report Date: 08/31/09 Expiration Date: 08/27/13 Project Summary: Architectural Testing, Inc. was contracted by Vtech Industries to perform testing on 4 x 4 CMC Hurricane Skylights. The sample tested met the Class 4 performance requirements set forth in the referenced test procedures. Test specimen description and results are reported herein. The sample was provided by the client. Test Procedures: The test specimens were evaluated in accordance with the following: Specification Test Standard for Impact Resistance Testing of Rigid Roofing Materials by Impacting with Freezer Ice Balls, Class No. 4473, FM Approvals (2005) Test Specimen Description: Product Type: Skylight Overall Size: 1302 mm (51-1/4") wide by 1302 mm (51-1/4") high Rough Opening Size (curb): 1283 mm (50-1/2") wide by 1283 mm (50-1/2") high Fixed Daylight Opening Size: 1140 mm (44-7/8") wide by 1140 mm (44-7/8") high Overall Area: 1.69 m 2 (18.24 ft 2 ) Finish: Black Polyurethane Frame Construction: One piece molded polyurethane. 2865 Market Loop Southlake, Texas 76092 phone: 817-410-7202 fax: 817-424-8463 www.archtest.com

92240.01-801-75 Page 2 of 5 Test Specimen Description: (Continued) Deck Construction: The wood test deck was 8' wide x 4' high and constructed with 2x4 pine lumber at the perimeter with one stud located at the midspan. The test deck was covered with 15/32" thick plywood decking secured to the test deck with #6 x 1-5/8" screws located 2" from each end and on 6" centers. Glazing Details: The unit was glazed using insulating glass with an overall thickness of 3/4". At the exterior of the unit was 5/32" tempered glass. An aluminum spacer system measuring 1/4" was used. At the interior was.120" Dupont Butacite PVB interlayer with one piece of 3/32" heat strengthened glass on each side. The insulating glass unit was integrally molded to the frame. Installation: The test unit was secured to a 2 x 10 spf curb using both screws and sealant. Screws used were #10 x 1-1/2" flat head Phillips located at 6" from each corner and 12" on center spacing thereafter and were located along the sides of the curb mount. The curbing was secured to the test deck with one #8 x 2" screw at each corner. Test Results: The following results have been recorded: FM 4473, Ice Ball Impact Resistance Sample Conditioning Temperature: 26 C (78 F) 4 hours Sample Conditioning Relative Humidity: 50% 4 hours Ice Ball Conditioning Temperature: -22 C (-7 F) 48 hours Muzzle Distance from Test Specimen: 914 mm (36") Impact #1: Missile Velocity: 35.23 m/s (115.6 fps); orientation 15 of vertical Missile Weight: 63.4 g (0.1398 lbs) Kinetic Energy: 29.03 ft-lb Impact Area: Bottom right corner 6" from bottom Impact #2: Missile Velocity: 34.44 m/s (113.0 fps); orientation 15 of vertical Missile Weight: 64.7 g (0.1426 lbs) Kinetic Energy: 28.31 ft-lb Impact Area: Bottom right corner 2" from bottom

92240.01-801-75 Page 3 of 5 Test Results: (Continued) Impact #3: Missile Velocity: 34.05 m/s (111.7 fps); orientation 15 of vertical Missile Weight: 64.1 g (0.1413 lbs) Kinetic Energy: 27.40 ft-lb Impact Area: Bottom left corner 2" from corner Impact #4: Missile Velocity: 35.02 m/s (114.9 fps); orientation 15 of vertical Missile Weight: 65.7 g (0.1448 lbs) Kinetic Energy: 29.72 ft-lb Impact Area: Bottom left corner 2" from corner Impact #5: Missile Velocity: 34.84 m/s (114.3 fps); orientation 15 of vertical Missile Weight: 63.2 g (0.1393 lbs) Kinetic Energy: 28.29 ft-lb Impact Area: Top left corner 2" from corner Impact #6: Missile Velocity: 34.44 m/s (113.0 fps); orientation 15 of vertical Missile Weight: 65.4 g (0.1442 lbs) Kinetic Energy: 32861 ft-lb Impact Area: Top left corner 2" from corner

92240.01-801-75 Page 4 of 5 Test Equipment: Cannon: Constructed from steel piping utilizing compressed air to propel the missile Missile: 50.8 mm (2") diameter ice balls Timing Device: Electronic Beam Type Timing Device Calibration Date: 08/12/09 List of Official Observers: Name Arthur Valentz Andy Cost Company Vtech Industries Architectural Testing, Inc. Data sheets, representative samples of test specimens, a copy of this report, or other pertinent project documentation will be retained by Architectural Testing, Inc. for a period of four years from the original test date. At the end of this retention period, such materials shall be discarded without notice and the service life of this report will expire. Results obtained are tested values and were secured by using the designated test methods. This report does not constitute certification of this product nor an opinion or endorsement by this laboratory. It is the exclusive property of the client so named herein and relates only to the specimen(s) tested. This report may not be reproduced, except in full, without the written approval of Architectural Testing, Inc. For ARCHITECTURAL TESTING, INC. Andy Cost Laboratory Manager John Waskow Director of Regional Operations AC:hd Attachments (pages): This report is complete only when all attachments listed are included. Appendix-A: Drawings (4)

92240.01-801-75 Page 5 of 5 Revision Log Rev. # Date Page(s) Revision(s) 0 09/01/09 N/A Original report issue 1 09/09/09 4 Corrected measurement of the diameter of the ice ball This report produced from controlled document template ATI 00371, issued 05/29/09.

92240.01-801-75 Appendix A Drawings