1 SIPS SCREWS WITH MINIMUM 1" PENETRATION IN WOOD MEMBER IN SIP WALL PANEL CONNECTED 24" O.C. MAXIMUM OUTSIDE SKIN EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY FOAM CORE AS EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY 8d COMMON 6" O.C. EACH SIDE WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION Fig. 2
2 SIP WALL SUBFLOOR OR COMBINED SUBFLOOR AND UNDERLAYMENT DRAINED AND VENTILATED CLADDING FLOOR JOIST FIELD INSTALLED PANEL BOTTOM PLATE 8d COMMON 6" O.C. BOTH SIDES BE SURE OUTSIDE SKIN IS SUPPORTED BY SILL PLATE CONCRETE OR MASONRY FOUNDATION WALL 16d NAILS INTO SILL 16" O.C. TREATED SILL PLATE SILL SEALER TERMITE SHIELD EACH SIDE OF FRAMING TYP. AS MINIMUM 1/2" (13MM) DIAMETER ANCHOR 6 FEET O.C. MAXIMUM FOUNDATION CONNECTIONS FOUNDATION CONNECTION DETAIL A Fig. 3
3 SIP WALL DRAINED AND VENTILATED CLADDING EACH SIDE OF FRAMING TYP. AS 8d COMMON 6" O.C. EACH SIDE CAPILLARY BREAK, MIN. 6 MIL POLY OR MIN. 3/4" PRESSURE- TREATED PLYWOOD UNDER SILL PLATE AND BOTH FACES TERMITE SHIELD FIELD INSTALLED TREATED BOTTOM PLATE MINIMUM 1/2" (13MM) DIAMETER ANCHOR 6 FEET O.C. MAXIMUM CONCRETE OR MASONRY FOUNDATION WALL FOUNDATION CONNECTIONS FOUNDATION CONNECTION DETAIL B Fig. 4
4 SIP WALL DRAINED AND VENTILATED CLADDING FIELD INSTALLED TREATED BOTTOM PLATE 8d COMMON 6" O.C. EACH SIDE SUBFLOOR OR COMBINED SUBFLOOR AND UNDERLAYMENT, TYP. FLOOR JOIST 16d NAILS INTO FLOOR JOIST 16" O.C. WHEN USED AS BRACING (3) 16 O.C. AT EACH SIDE OF FRAMING TYP. AS USE NAILS PER S RECOMMENDATIONS FOR SIZE AND SPACING CONCRETE OR MASONRY FOUNDATION WALL TREATED SILL PLATE CAPILLARY BREAK, MIN. 6 MIL POLY OR MIN. 3/4" PRESSURE-TREATED PLYWOOD UNDER SILL PLATE AND BOTH FACES ANCHOR BOLT AS REQUIRED BY CODE FOUNDATION CONNECTIONS FOUNDATION CONNECTION DETAIL C Fig. 5
5 FINISH ROOFING MATERIAL ROOFING FELT EACH SIDE OF FRAMING AND BOTH FACES AS RECOMMENDED BY 8d COMMON 6" O.C. BOTH SIDES FOAM RIDGE CAP SIP ROOF PANEL SEALANT AS SIPS SCREWS WITH 1" MIN. PENETRATION INTO STRUCTURAL 24" O.C. MINIMUM SIP TAPE AT RIDGE REQUIRED CONTINUOUS FIELD INSTALLED WOOD RIDGE SUPPORT BEAM SHOWN STRUCTURAL SUPPORT MEMBER WITH MIN. 1-1/2" BEARING FOR EACH SIDE OF PANELS ROOF-TO-ROOF PANEL CONNECTIONS FOAM RIDGE CAP DETAIL Fig. 6
6 FINISHED ROOFING MATERIAL ROOFING FELT MINIMUM 3/8" GAP FOR SEALANT AS BLOCKING AS REQUIRED BY STRUCTURAL CONDITIONS SIPS SCREWS W/ MINIMUM 1" PENETRATION INTO STRUCTURAL 24" O.C. MINIMUM SIP TAPE AT RIDGE REQUIRED RIDGE SUPPORT BEAM ROOF-TO-ROOF PANEL CONNECTIONS BEVELED SIP RIDGE DETAIL Fig. 7
7 PANEL SCREW FINISHED ROOFING MATERIAL ROOFING FELT SIP ROOF PANEL CONTINUOUS SEALANT EACH SIDE OF FRAMING AS RECOMMENDED BY, AND ROOF PANEL 2x JOINT 8d COMMON 6" O.C. EACH SIDE TOP PLATE SIP WALL PANEL DRAINED AND VENTILATED CLADDING ROOF-TO-WALL PANEL CONNECTIONS BEVELED SIP WALL Fig. 8
8 WEDGE INFILL PIECE PANEL SCREW FINISHED ROOFING MATERIAL ROOFING FELT SIP ROOF PANEL EACH SIDE OF FRAMING AS CONTINUOUS SEALANT EACH SIDE OF FRAMING, AND ROOF PANEL 2x JOINT TOP PLATE SIP WALL PANEL DRAINED AND VENTILATED CLADDING 8d COMMON 6" O.C. BOTH SIDES EACH SIDE OF FRAMING AS ROOF-TO-WALL PANEL CONNECTIONS WEDGE INFILL PIECE Fig. 10
9 8d COMMON NAILS 6" O.C. BOTH SIDES TYPICAL AS FINISHED ROOFING MATERIAL BOTH SIDES TYP. OF FRAMING AS RECOMMENDED BY 16d COMMON 16" O.C. ROOFING FELT SIP TAPE AT RIDGE REQUIRED ROOF-TO-ROOF PANEL CONNECTIONS RIDGE DETAIL AT CANTILEVER (LIMIT 2' OVERHANG) Fig. 11
10 SIP WALL PANEL SECOND FLOOR STANDARD WIRE CHASE 16d COMMON 16" O.C. WHEN USED AS BRACING (3) 16d COMMON 16" O.C. DRAINED AND VENTILATED CLADDING 2x BOTTOM PLATE 8d COMMON 6" O.C. BOTH SIDES EACH SIDE OF FRAMING TYP. AS 3/4" T&G FLOOR SHEATHING (GLUED & NAILED) TO EXTEND OVER TOP OF SIP WALL FLOOR JOISTS METAL STRAP AS REQUIRED OR LTP4 SIMPSON CLIP CAP PLATE EACH SIDE OF FRAMING TYP. AS TOP FLANGE METAL FLOOR JOIST HANGAR (BY OTHERS) FIRST FLOOR 2ND FLOOR CONNECTION DETAILS HANGING FLOOR Fig. 12
11 SIP WALL PANEL SECOND FLOOR STANDARD WIRE CHASE DRAINED AND VENTILATED CLADDING 16d COMMON 16" O.C. WHEN USED AS BRACING (3) 16d COMMON 16" O.C. 2x BOTTOM PLATE 8d COMMON 6" O.C. BOTH SIDES INSULATION 3/4" T&G FLOOR SHEATHING (GLUED & NAILED) TO EXTEND OVER TOP OF SIP WALL FLOOR JOISTS (I-JOIST SHOWN) METAL LATERAL TIE PLATE NAILED TO BOTTOM OR SHIM PLATES AND RIM BOARD RIM BOARD METAL LATERAL TIE PLATE NAILED TO BOTTOM OR SHIM PLATES AND RIM BOARD 8d COMMON 6" O.C. BOTH SIDES FIRST FLOOR EACH SIDE OF FRAMING TYP. AS CAP PLATE AS REQUIRED BY EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY 2ND FLOOR CONNECTION DETAILS RIM BOARD Fig. 13
12 SIP ROOF PANEL ROOFING FELT FINISHED ROOFING MATERIAL AS REQUIRED, EXTEND ICE AND WATER SHIELD FROM FASCIA. CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS AS DRIP EDGE FLASHING ROOF-TO-WALL PANEL CONNECTION DETAIL SHOWN ELSEWHERE FASCIA SOFFIT BOARD EAVES DETAILING EAVES DETAIL A Fig. 14
13 SIP ROOF PANEL ROOFING FELT AS REQUIRED, EXTEND ICE AND WATER SHIELD FROM FASCIA EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY FINISHED ROOFING MATERIAL DRIP EDGE FLASHING AS 2X BLOCKING TO SUPPORT FASCIA BOARD ROOF-TO-WALL PANEL CONNECTION DETAIL SHOWN ELSEWHERE 8d COMMON 6" O.C. BOTH SIDES FASCIA 2x FRAMING MEMBER SOFFIT BOARD SIP SCREW EAVES DETAILING EAVES DETAIL B Fig. 15
14 ROOFING FELT SIP ROOF PANEL AS REQUIRED, EXTEND ICE AND WATER SHIELD FROM FASCIA. FINISHED ROOFING MATERIAL EACH SIDE OF FRAMING TYP. DRIP EDGE 2x FRAMING MEMBER USE NAILS PER 'S RECOMMENDATIONS FOR SIZE AND SPACING. 2x FRAMING MEMBER FASCIA SOFFIT BOARD 8d COMMON 6" O.C. BOTH SIDES SIP SCREW EAVES DETAILING EAVES DETAIL C Fig. 16
15 AS REQUIRED, EXTEND ICE AND WATER SHIELD FROM FASCIA EACH SIDE OF FRAMING TYP. AS ROOFING FELT SIP ROOF PANEL FINISHED ROOFING MATERIAL DRIP EDGE FLASHING BEVELED BLOCKING TO SUPPORT FASCIA BOARD 8d COMMON 6" O.C. BOTH SIDES AS ROOF-TO-WALL PANEL CONNECTION DETAIL SHOWN ELSEWHERE FASCIA SOFFIT BOARD USE NAILS PER 'S RECOMMENDATIONS FOR SIZE AND SPACING. EAVES DETAILING EAVES DETAIL D Fig. 17
16 FINISHED ROOFING MATERIAL AS REQUIRED, EXTEND ICE AND WATER SHIELD FROM FASCIA EACH SIDE OF FRAMING TYP. AS ROOFING FELT SIP ROOF PANEL DRIP EDGE 8d COMMON 6" O.C. BOTH SIDES AS ROOF-TO-WALL PANEL CONNECTION DETAIL SHOWN ELSEWHERE FASCIA SOFFIT BOARD USE NAILS PER 'S RECOMMENDATIONS FOR SIZE AND SPACING. EAVES DETAILING EAVES DETAIL E Fig. 18
17 EACH SIDE OF FRAMING TYP. AS SIP PANEL EXPANSION GAP 1/8" 8d COMMON 6" O.C. EACH STRIP AND EACH SIDE SEALANT AS RECOMMENDED BY CHASE FOR EXPANDED FOAM SEALANT WALL-TO-WALL VERTICAL PANEL CONNECTIONS SURFACE SPLINE FOR VERTICAL SPLICE Fig. 19
18 2x FRAMING AROUND WINDOWS AND DOOR OPENINGS DOOR AND WINDOW FRAMING Fig. 21
19 (2) ROWS 16d COMMON 16" O.C. MINIMUM SIP PANEL EXPANSION GAP 1/8" 8d COMMON 6" O.C. EACH PANEL AND EACH SIDE EACH SIDE OF FRAMING TYP. AS WALL-TO-WALL VERTICAL PANEL CONNECTIONS DIMENSIONAL LUMBER SPLINE Fig. 20
20 EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY VALLEY FLASHING DOUBLE 2x SPLINE BEVEL CUT SIP ROOF PANEL 16d COMMON 16" O.C. MINIMUM 8d COMMON 6" O.C. EACH PANEL AND EACH SIDE EACH SIDE OF FRAMING TYP. AS AT SUPPORT MEMBERS SIPS SCREW W/ MINIMUM 1" PENETRATION INTO STRUCTURAL SUPPORT STRUCTURAL SUPPORT SIP TAPE ROOF-TO-ROOF PANEL CONNECTIONS VALLEY DETAIL Fig. 22
21 SIP PANEL EXPANSION GAP 1/8" 8d COMMON 6" O.C. EACH PANEL AND EACH SIDE EACH SIDE OF FRAMING TYP. AS BLOCK SPLINE WALL-TO-WALL VERTICAL PANEL CONNECTIONS BLOCK SPLINE Fig. 23
CONSTRUCTION DETAILS & LOAD DESIGN CHARTS
Office and Production 126 New Pace Rd., PO Box 279 Newcomerstown, OH 43832 1-800-446-2188, Fax: 740-498-4184 www.buildwithsips.com CONSTRUCTION DETAILS & LOAD DESIGN CHARTS Table of Contents Description
More informationAdditions and Alterations
Additions and Alterations Addition and alteration construction is a miscellaneous grouping of home improvement and renovation projects that are generally geared toward the enhancement of an existing principal
More informationThe better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs
The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs February 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements...................................
More informationPANELIZED HOME INSTALLATION GUIDELINE
PANELIZED HOME INSTALLATION GUIDELINE A typical home package will be constructed of Snap-N-Lock Insulated Panels clad with steel skins. 4" panels will be used for the walls, and 6" panels for the roof.
More informationSuperform Products Ltd.
TYPICAL CORNER REINFORCING NOTE : SEE ENGINEERED REBAR SCHEDULES SUPPLIED BY THE MANUFACTURER STEEL REINFORCEMENT WALL CORNER 90 Copyright 2012 Sept. 2012 5.1.1 Rebar Spacing 6" 12" Max. Load LB./FT. 2000
More informationFree 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details
Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details Brought To You By: MyShedPlans Click Here To Download 12,000 Shed Plans >> 12 x 8 Basic Shed This 8 12-ft. shed features a simple
More informationINSTALLATION OF A BAY WINDOW
INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening
More informationHURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES 101 Retrofits Required. Pursuant to Section 553.844 553.884, Florida Statutes, strengthening of existing site-built,
More informationMarch 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
More informationCustom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems
P O Box 34 Mendon, Utah Custom 30 x 20-8 Garage Plan Plan #g233 By Page 1 Title Page Page 2 Main Floor Plan Page 3 Foundation Plan Page 4 Elevation Views Page 5 Framing and Details Page 6 Typical Section
More information8/18/14. Introduction to. Framing. Terminology and Concepts
8/18/14 Introduction to Framing Terminology and Concepts Terminology: Framing Level Two points on exactly the same horizontal plane. Square Intersecting lines or faces that form an exact 90 angle. Plumb
More informationNCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:
More informationBest Barns USA Assembly Book
Best Barns USA Assembly Book Revised November 27, 2013 the Easton - R 12'x 20' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 724-646-3775 This manual is copyrighted.
More informationA0 SHEET 1 OF 5 400 LOCUST STREET FRANKFORT, KANSAS 66427 FRANKFORT, KANSAS 66427 ROOF REPAIR OF THE 400 LOCUST STREET
POYNTZ AVENUE, STE 9 MANHATTAN, KS 0..0..9 FAX WEST th STREET JUNCTION CITY, KS.... FAX 0, Bruce McMillan AIA, Architects, P.A. HERITAGE TRUST FUND GRANT PROJECT NO. 0-0 ROOF REPAIR OF THE 00 LOCUST STREET
More informationMark Cramer Inspection Services, Inc.
Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction
More informationThe better way to build TM. Installation Manual. EXTERIOR WALL SIPs
The better way to build TM Installation Manual EXTERIOR WALL SIPs July 2015 EXTERIOR WALL SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................
More informationResidential Decks. Planning and Development Services Department
Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email: permitservices@opkansas.org Planning and Development Services Department Residential Decks
More informationNRG 75 CRF NRG GREENBOARD WALL SYSTEM
NRG GREENBOARD WALL SYSTEM NRG Energy Efficient Building Systems is pleased to announce a revolution in lightweight cladding systems. NRG Building Systems is the first and only company to achieve CodeMark
More informationInstallation Guide. Bath and Wall Surrounds SERIES 7104 1021861-2-B
Installation Guide and Wall Surrounds SERIES 7104 1021861-2-B Thank You For Choosing Sterling We appreciate your commitment to Sterling value. Please take a few minutes to review this manual before you
More informationHow To Repair A Boat Landing Deck With A Boat Bed
RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD IS Table of Contents Slab-on-grade-to Above Grade Wall...1 Foundation Wall at Footing
More information!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035
Decra Plus Drawing no DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 Description Shown In Decra Brochure Most Commonly Used Detail t~êã=oççñ=b~îéë=aéí~áä=b~îéë=lîéêü~åö=táíü=fåëìä~íéç=c~ëåá~=~åç=pçññáí
More informationElectrical Wiring Technical Bulletin
Electrical Wiring Technical Bulletin Overview In general, SIP construction is easier and more cost effective when things are planned and thought out before the panels are manufactured. This process will
More informationapplication instructions
application instructions ARCHITECTURAL COLLECTION PRIMED BOLD PROFILE 120 SERIES LAP SIDING (D5, T4, D8, T5, Q4) General At the time of manufacture, siding meets or exceeds the performance standards set
More informationMUNICODE SERVICES LTD.
The Preserved Wood Foundation Guide MUNICODE SERVICES LTD. Prepared by MuniCode Services Ltd. Outline and Restrictions of this Guide The following information required for the construction of Preserved
More informationResidential Roofing Guide
Residential Roofing Guide TABLE OF CONTENTS Building Detail and Accessories...... 1 Panel Introduction and Handling...... 2 Cutting and Trimming.... 3 Roof Preparation..... 3 Roof Slope..... 3 Re-roofing...
More information4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.
GENERAL CODE REQUIREMENTS (BASEMENTS) 1. FOOTINGS a. Footings shall be below frost line depth (42"). b. For an 8" foundation wall, footings shall be no less than 8" deep and 16" wide. c. Steel reinforcement
More informationDetached accessory structures that contain no conditioned floor area are exempt.
RESIDENTIAL ROOFING PERMITS: A roofing permit is required for roofing of residential dwellings and garages in accordance with Section R105 of the International Residential Code. Updated 11/2013 City of
More informationAsphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
More informationAMERICAN GOTHIC PLAYHOUSE
AMERICAN GOTHIC PLAYHOUSE Project Plan #856 Sheet 1 of 5 Pick a spot and get started with the beautiful that your kids will love. The design of the playhouse includes 35 square feet of interior space plus
More informationSUPER SHED. Indoor shelter for your outdoor tools.
SUPER SHED Indoor shelter for your outdoor tools. Not everyone needs a garden shed. But, if you've no more space on your garage wall for that new leaf rake, if you can't find your potting trowel because
More informationENERGY STAR Qualified New Homes Thermal Enclosure Checklist. Water Management Checklist. Eli Caudill
ENERGY STAR Qualified New Homes Thermal Enclosure Checklist & Water Management Checklist Eli Caudill ENERGY STAR Version 3 Tighter Standards Whole Home Approach Better, More Sustainable Construction Surpasses
More informationTYPICAL PATIO COVERS 111
City of Laguna Niguel Building Division 30111 Crown Valley Pkwy Laguna Niguel, CA 92677 (949) 362-4360 FAX 362-4369 www.cityoflagunaniguel.org TYPICAL PATIO COVERS 111 PLEASE NOTE: This information Bulletin
More informationPDmB, Inc. Definitions
Page 1 of 11 Definitions S Satisfactory Meets industry standards for proper material and installation NP Not Present Condition or item was not present at time of inspection NI Not Inspected Condition or
More informationThe WANZ Guide to Window Installation
The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5 Ver. 1.1 Page 2 of 74 Contents Overview Page 5 Objective Page 5 Scope Page 5 Opening Preparation Page 7 Step P1 Preliminary Check
More information6 RETROFITTING POST & PIER HOUSES
Retrofitting Post & Pier Houses 71 6 RETROFITTING POST & PIER HOUSES by James E. Russell, P.E. 72 Retrofitting Post & Pier Houses Retrofitting Post & Pier Houses 73 RETROFITTING POST AND PIER HOUSES This
More information2.9 WINDOW & DOOR BUCKS
2.9 WINDOW & DOOR BUCKS Bucks provide attachment surfaces for windows and doors while holding back concrete from these openings during concrete placement. Mark the center and edges of openings as you place
More informationPOST AND FRAME STRUCTURES (Pole Barns)
POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:
More informationSTANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS
ROOFING APPLICATION STANDARD (RAS) No. 133 STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS 1. Scope 1.1 This application standard has been developed to provide consistent information for the
More informationSTANDARD OPEN PATIO COVER
STANDARD OPEN PATIO COVER BUILDING & SAFETY DIVISION 201 E. LA HABRA BLVD. LA HABRA, CA 90631 62-90-9710 Call Before You Dig 1-800-227-2600 PLEASE NOTE: This information Bulletin is made available to assist
More informationLIGHT FLOOR AND WALL FRAMING
CHAPTER 1 LIGHT FLOOR AND WALL FRAMING In the normal sequence of construction events, the floor and wall activities follow the completed foundation work. In this chapter, we ll examine established methods
More informationDETAILED INSTALLATION GUIDE
DETAILED INSTALLATION GUIDE Warning: Risk of Electrical Shock, Fire or Personal Injury Once Installed and your wiring is run through your SMARTWALL system there is risk of electrical shock, fire or personal
More informationThe Closed Crawl Space: Making the Transition Climate Zones 3A & 4A
TechSpecs A builder s blueprint for construction technologies January 2013 The Closed Crawl Space: Making the Transition Climate Zones 3A & 4A C B A E D H G F A. Wood Floor Framing - p. 2 B. Foundation
More information300mm. 2mm MIN GAP. PLACE 100mm X 100mm. SO THAT IT IS 38mm INTO
INSTALL PEEL & STICK (P&S) GUSSETS WITH PRIMER AS PER MANUFACTURERS INSTRUCTIONS 2mm MIN GAP IN SHEATHING STEP 1 PLACE 100mm X 100mm PIECE OF P&S IN CORNER SO THAT IT IS 38mm INTO THE OPENING EACH WAY
More informationChapter 6 ROOF-CEILING SYSTEMS
Chapter 6 ROOF-CEILING SYSTEMS Woodframe roof-ceiling systems are the focus of this chapter. Cold-formed steel framing for a roof-ceiling system also is permitted by the IRC but will not be discussed;
More informationFinal inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
More informationRESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
More informationTHE DOW CHEMICAL COMPANY Issued: August 1, 2008 200 LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN 48674 (989) 638-8655 www.dowbuildingmaterials.
ICC EVALUATION SERVICE, INC. EvaluateP InformP Protect Los Angeles Business/Regional OfficeP 5360 Workman Mill RoadP Whittier, CA 90601 (562) 699-0543 phonep (562) 695-4694 fax DIVISION: Section: 6 WOOD
More informationWINDOW PANNING AND TRIMS
OCTOBER, 2010 PANNING AND TRIMS GENERAL INFORMATION 1 EXTERIOR PANNING Panning is primarily used to cover the perimeters of existing building openings prior to the installation of replacement windows.
More informationLinea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1
Top plate Stud Soffit lining 45mm min nog Fix scotia bead Building underlay/james Hardie rigid air barrier Soffit Detail Building underlay/james Hardie rigid air barrier Bottom plate 25mm wide cant strip.
More informationCPA Steel Stud Framing Page 1 of 11
CPA Steel Stud Framing Page 1 of 11 STEEL STUD FRAMING General Requirements City of Palo Alto (CPA) Building Inspection Division 285 Hamilton Ave. Inspection Request: 650 329-2496 Building Division IVR#
More informationInstallation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows
Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows americancraftsmanwindows.com Project Requirements: Read
More informationProtecting Your Home From Hurricane Wind Damage
T H E W I N D Protecting Your Home From Hurricane Wind Damage During a hurricane, homes may be damaged or destroyed by high winds and high waves. Debris can break windows and doors, allowing high winds
More informationStorage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.
Installation Guide Before you begin, take the time to read this entire guide to clearly understand the requirements and steps to follow for proper installation. Warning Do not install defective material.
More informationTable of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..
Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3
More informationFraming a Crawl-Space Foundation These timesaving tips make short work of setting sills, posts and girders
Framing a Crawl-Space Foundation These timesaving tips make short work of setting sills, posts and girders by Larry Haun There is no "best" foundation. Depending on what part of the country you live in,
More informationWindow Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for
More informationHfHMD uses LP SmartSide siding and trim.
HfHMD uses LP SmartSide siding and trim. These products are: More durable than cement fiber board. Much more volunteer-friendly to install. When installed correctly, have a 5/50- year pro-rated warranty.
More informationGood Craftsmanship Guide. Carpentry and Joinery- Carcassing
Good Craftsmanship Guide Carpentry and Joinery- Carcassing Introduction This Good Craftsmanship Guide highlights key problems with the major elements of Carpentry and Joinery - Carcassing, and gives guidance
More informationPatio Covers / Carports
Patio Covers / Carports Building Guides for Homeowners Why Do I need a Permit? D I D Y O U K N O W? As owner-builder you are the responsible party of record on such a permit. If your work is being performed
More informationWe urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.
Important Information for New Construction Installations Attention Installer! We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden
More informationUncovered Decks & Porches
Uncovered Decks & Porches Building Guides for Homeowners Why Do I need a Permit? D I D Y O U K N O W? As owner-builder you are the responsible party of record on such a permit. If your work is being performed
More informationReport on Sanctuary/Chancel Crawl Space Inspection. St. John in The Wilderness, 2896 Old Lakeshore Road Bright s Grove. Project No.
Report on Sanctuary/Chancel Crawl Space Inspection St. John in The Wilderness, 2896 Old Lakeshore Road Bright s Grove Project No. E112056 1. Background St. John in the Wilderness (SJITW) is considering
More informationWalls. Add Strength and Water Resistance When Repairing Your. Replace damaged framing members when walls are open
Add Strength and Water Resistance When Repairing Your Walls Any home repair or remodeling work you do presents an opportunity to make your home fare better in the next storm. Whether you are just replacing
More informationSection A Roof Truss
Section A Roof Truss Truss Types Wisconsin Truss, Inc. can build a variety of truss types, pictured below are some common examples. Common Bobtail Scissor Mono Studio Dual Slope Cathedral Tray Vault Parallel
More information609 West Rock Road, Radford,VA 24141 540-633-5000 / (fax) 540-731-3712 RECOMMENDED ATTACHMENTS & CONNECTION DETAILS
609 West Rock Road, Radford,VA 24141 540-633-5000 / (fax) 540-731-3712 RECOMMENDED ATTACHMENTS & CONNECTION DETAILS INDEX OF DRAWINGS SECTION A: A-1 = METAL TRACK TO PANEL ATTACHMENT A-2 = WOOD PLATE TO
More informationWe urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.
Important Information for New Construction Installations Attention Installer! We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden
More informationAC-3200 ALUMINUM PLATE SYSTEM (DRY JOINT)
ALUMINUM PLATE SYSTEM (DRY JOINT) C D E G P J L A H M B Q F A B C D E F G H J K L M N P Q R HORIZONTAL JOINT DETAIL VERTICAL JOINT DETAIL COPING DETAIL (1) COPING DETAIL (2) COPING DETAIL (3) OUTSIDE CORNER
More informationEnvelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit
R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed
More informationBuilding Construction. Lightweight construction. Conventional Construction
Ventilation 53 Building Construction The firefighter s ability to safely and efficiently ventilate a building through its roof will depend to some degree on the firefighter s understanding of roof construction.
More informationThis handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.
Residential Decks Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org
More informationBrick Veneer Construction
Brick Veneer Construction Check list of suggested tools & support items Claw hammer Tape measure 3/4" [19 or 20] Wood chisel Wood or plastic shims Pry bar Utility knife Caulking and caulking gun Power
More informationROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof
ROOF CONSTRUCTION The overall appearance of a building is greatly affected by the roof lines and the roofing materials. The designer has many standard designs to choose from and should be able to find
More informationTable of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide
Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3
More information6.0 Implementation: Retrofitting Gable End Walls with L-Bent Straps
6.0 Implementation: Retrofitting Gable End Walls with L-Bent Straps Order of presentation: To give you a better appreciation of what is involved in doing a gable end bracing retrofit, the first section
More informationResidential Building Inspection Policies
CONCRETE 1. A footing inspection has been called in, but a monolithic slab shows on the plans. Cancel the footing and create a slab inspection, as long as there is a Passed Plumbing Rough (05). 2. A stemwall
More informationPage & Turnbull imagining change in historic environments through design, research, and technology
DCI+SDE STRUCTURAL EVALUATIONS OFFICE BUILDING, TOOL SHED & WATER TANK, AND BLACKSMITH & MACHINE SHOP BUILDINGS SAN FRANCISCO, CALIFORNIA [14290] PRIMARY PROJECT CONTACT: H. Ruth Todd, FAIA, AICP, LEED
More informationScrew Patterns Roof & Walls 403-279-2766 TR-36 MD-36 TSM-32. PBR-Panel
Screw Patterns Roof & Walls Overlap Underlap ¾ 9 TR-36 36 5/8 6 MD-36 36 ½ 8 TSM-32 32 1¼ 12 PBR-Panel 36 Bottom Edge Screw Pattern apply to every profile except for MD36 (1 screw beside every rib) High
More informationThe WANZ Guide to Window Installation
The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5 2 of 60 Contents Overview 5 Objective 5 Scope 5 Opening Preparation 7 Step P1 Preliminary Check 8 Step P2 Cut the Underlay 9 Step
More informationSTRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM
Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally
More informationCOMMONLY USED RESIDENTIAL BUILDING CODES
COMMONLY USED RESIDENTIAL BUILDING CODES INTERNATIONAL RESIDENTIAL CODE (2009) form revised 5/10 FOUNDATION 1. DESIGN OF FORMWORK. Section 1906.1 IBC 2009, Section R404.1.2.3.6 IRC 2009, ACI 318 Section
More informationClad Direct Glaze Window Installation Instructions
Clad Direct Glaze Window Installation Instructions Sill flashing and sealing: 2. An overview of the proper flashing sequence is shown in figure 1. Please read entire installation instructions carefully
More informationDE Frame with C Series Sidelight
TOOLS REQUIRED Tape measure 6' magnetic level 3' magnetic level Screw gun with clutch adjusted #2 phillips tip #3 phillips tip Screwdriver (used to adjust frame on will using oval slots) Pry Bar Powder
More informationDEFAULT HEAT LOSS COEFFICIENTS
DEFAULT HEAT LOSS COEFFICIENTS SECTION A101 GENERAL REQUIREMENTS A101.1 Scope. The following defaults shall apply to Chapter 4 of both the (RE) and (CE) sections of the IECC. This chapter includes tables
More informationManaging Trade Contractors for High Performance Homes. Carl Seville
Managing Trade Contractors for High Performance Homes Carl Seville Overview Implementing Management Systems Why How Steps Troubleshooting Successes High Performance Buildings Attention to detail Management
More informationChapter 9: INSTALLING ROOFING
9.1 LEAK BARRIER (ICE AND WATER SHIELD) 9.2 SHINGLE UNDERLAYMENT 9.3 INSTALLING GUTTER APRON AND GABLE D-EDGE 9.4 INSTALLING SHINGLES 9.5 RIDGE VENT AND CAP Tools needed by each volunteer: Hammer (16 oz.
More informationChapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
More informationROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS
ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS 1. 2. 3. 3.0 Scope 1.1 This application standard shall be used where the authority having jurisdiction has adopted its use, and
More informationDrexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood
Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood Section 07411 Metal Roof Panels Part 1 General 1.1 Summary A. This section includes the following: a. Factory-formed
More informationRetrofitting an Insulated Cold Roof
Retrofitting an Insulated Cold Roof As a metal-roofing contractor in the Upper Peninsula of Michigan, I am frequently asked to fix roof leaks that have less to do with roofing than with the way poorly
More informationG VYCOR DECK PROTECTOR
G VYCOR DECK PROTECTOR Self-Adhered Flashing Contractor s Guide DECKS AND DETAIL AREAS For longer lasting decks, install Grace Vycor Deck Protector. FROM THE MAKERS OF G Ice & Water Shield What Self-Adhered
More informationStructural Insulated Panels PRODUCT GUIDE
Structural Insulated Panels PRODUCT GUIDE 2007 APA THE ENGINEERED WOOD ASSOCIATION ALL RIGHTS RESERVED. ANY COPYING, MODIFICATION, DISTRIBUTION OR OTHER USE OF THIS PUBLICATION OTHER THAN AS EXPRESSLY
More informationH-Stud Area Separation Wall System
12 TH EDITION 09 21 16.33/NGC H-Stud Area Separation Wall System 09 21 16.33 139 H-STUD AREA SEPARATION WALL SYSTEM The fire-protection of gypsum-based Area Separation Walls is demonstrated in dramatic
More informationPREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS
Application Instructions for THESE ARE THE MANUFACTURER S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS, INC. ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING
More informationTypical Deck Details
Fairfax County, Virginia Typical Deck Details Based on the 2012 Virginia Residential Code The design details in this document apply to residential, single-level decks only. Construction cannot deviate
More informationBUILD A CARPORT. 2 - Planning the carport. 3 - Designing the carport
BUILD A CARPORT You only need basic DIY and woodworking skills to build a carport. The most important part of the job is setting the supporting posts truly vertical - a job for which another pair of hands
More informationLINE OF EXISTING ADJACENT STRUCTURE 6" MIN. PROTECTION COURSE (NOT REQUIRED WHERE THERE IS NO ADJACENT BLDG. MOISTURE RESISTIVE MEMBRANE AT EXIST. AND NEW BLDG. AS OCCURS WATER STOP SLAB-ON-GRADE TERMINATION
More informationFORM DESIGN. easy to work with, and generally available.
Forms play a major role in concrete construction. They give the plastic concrete its shape and hold it until it hardens. Forms protect the concrete, assist in curing it, and support any reinforcing rods
More informationSun Windows General Information Sun New Construction Window Installation Instructions
Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten
More informationSINGLE-FAMILY EARTHQUAKE (SEISMIC) RETROFITS
CITY OF BEAVERTON Community Development Department Building Division 12725 SW Millikan Way / PO Box 4755, Beaverton, OR 97076 Phone: (503) 526-2493 Fax: (503) 526-2550 General Information (503) 526-2222
More informationnecessary for years of satisfactory service. SmartBlock insulating form concrete walls share the
Chapter 7 PLUMBING AND ELECTRICAL 7.1 Introduction to Plumbing and Electrical Consideration of support services such as plumbing and electrical systems from the preliminary schematics phase through final
More information