Power Distribution [CTLOGUE TB2CT] TEMBREK 2 MOULDED CSE CIRCUIT BREKERS Innovators in Protection Technology INDUSTRIL SWITCHGER & UTOMTION SPECILISTS Beyond the Standard [1] www.nhp.com.au www.nhpnz.com
MOULDED CSE CIRCUIT BREKERS MIN CONTCT / TOGGLE STTUS VISIBILITY Simply... Beyond the Standard Easy accessory fitting ON (I) OFF (O) TRIPPED Double insulated MCCB Opening force is transmitted directly from the toggle switch Contacts separated Maintenance can be performed on the load side 1 / 0 adjustment flexibility Clear contact status TemBreak 2 MCCBs are marked with the IEC symbol indicating Direct Opening ction. The robust mechanism ensures that the force applied to the toggle is transmitted directly to the contacts. Symmetrical design Elec / Mech endurance Isolation and Machine Safety Complies with direct action contact status requirements. Low temperature rise Higher harmonic immunity High insulation voltage [2]
MOULDED CSE CIRCUIT BREKERS TEMBREK 2 Simply flexible Positive OFF/ON operation. The toggle mechanism is directly driven by the MCCB main contacts. The label logo below indicates this fact. Common internal accessories 1 6 ll internal and external accessories are field installable Thermal Magnetic or Electronic Trip units Thermal Magnetic 1, 0 and 0 MCCBs MCCBs are fitted with adjustable thermal ND adjustable magnetic current adjustment dials Electronic MCCB range From to 6 2 frame sizes: 0 and 0/6 [3]
MOULDED CSE CIRCUIT BREKERS ELECTRICL CHRCTERISTICS ccording to IEC 609472, EN 609472, JIS C 812, S/NZS 39472, NEM Maximum rated current Quantity In Units Condition / C 1 160 Model E1 S1 H1 L1 S160 H160 L160 Number of poles 1 1 Type NF GJ NF GJ Rated Breaking Icu k 690 V C 6 6 Capacity 4 V C 1 1 380/4 V C * 1 * 1 2/2 V C 0 V DC Ics k 690 V C 6 6 4 V C 12 380/4 V C 13* 33 * 2/2 V C 27 13 0 V DC Rated Breaking Capacity, k 480 V C 8 NEM 2 V C * Outline Dimensions h mm 5 1 1 1 1 w mm 3 pole, (1 pole) 90, () () w mm 4 pole 1 1 1 1 1 d mm 68 68 Utilisation Category vailable Protection djustable thermal, adjustable magnetic Units Fixed thermal, fixed magnetic Microprocessor These characteristics are the same for all products on this page. Rated C and DC insulation voltage Ui V 800 Rated impulse withstand voltage Uimp kv 8 Rated operational voltage Ue V C 690 Suitable for isolation Yes Direct opening action Yes 12 to 1 application * Breaking capacity shown is at 1/ 3 times the standard voltage. 12 to 0 application TemBreak 2 switchdisconnectors are available with the same frame dimensions as the MCCBs. [4]
MOULDED CSE CIRCUIT BREKERS E0 12 27 10 0 0 6 S0 GJ PE 70 1 70 1 1 H0 1 L0 1 E0 S0 CJ NE GJ GE 70 70 H0 L0 E6 S6 1 NE 1 1 NE 1 NE 10 10 CE GE 70 1 1 260 260 1 1 1 1 1 1 68 1 to 6 application [5]
MOULDED CSE CIRCUIT BREKERS INTERNL CCESSORIES One size fits all! General purpose types uxiliary larm Heavy duty types uxiliary larm Shunt UVT SMRT CCESSORIES SIMPLY SFE Common accessory range from 1F to 6F Double insulated MCCB allowing accessory fitting while live TemBreak 2 accessory types reduce part numbers, stock, make supply more customer friendly, reduce lead times ll accessories meet IEC 60 9475, S/NZS 39475 Endurance tested accessories not normally done by many manufacturers [6]
MOULDED CSE CIRCUIT BREKERS EXTERNL CCESSORIES Simple to fit TemPlug simple plug in method for MCCBs 1 to 6 Transfer switch Link interlock llows for handles and motors to be mounted Transfer switch Wire interlock Horizontal, vertical or diagonal MCCB mounting allows for handles and motors to be mounted Motor fitting Simple, quick installation in seconds requiring no tools on 1 / 0 MCCBs. Larger MCCBs only require a screwdriver Variable and fixed depth handles Simple, quick installation in seconds requiring no tools on 1 / 0 MCCBs. Larger MCCBs only require a screwdriver. IP 54 or IP handles Terminal covers Slideon and click into place, no tools required Plug in MCCB Safety interlock standard to maximise safety [7]
USTRLI www.nhp.com.au VICTORI MELBOURNE HEDQURTERS 47 River Street Richmond Victoria 3121 Telephone +61 3 9429 2999 Fax +61 3 9429 1075 Email melsales@nhp.com.au NTIONL DISTRIBUTION ND MNUFCTURING CENTRE 104106 William ngliss Drive Laverton North Victoria 26 Telephone +61 3 9429 2999 Fax +61 3 98 2997 Email melsales@nhp.com.au TSMNI HOBRT 2/ lbert Road Moonah Tasmania 7009 Telephone +61 3 68 9575 Fax +61 3 68 9757 Email tassales@nhp.com.au QUEENSLND BRISBNE 16 Riverview Place Murarrie Queensland 4172 Telephone +61 7 3909 4999 Fax +61 7 3399 9712 Email brisbranch@nhp.com.au TOWNSVILLE 62 Leyland Street Garbutt Queensland 4814 Telephone +61 7 4779 0700 Fax +61 7 4775 17 Email tsvbranch@nhp.com.au ROCKHMPTON 14 Robison Street Rockhampton Queensland 4701 Telephone +61 7 4927 77 Fax +61 7 49 2947 Email rkhbranch@nhp.com.au TOOWOOMB Cnr Carroll St & Struan Crt Toowoomba Queensland 43 Telephone +61 7 4634 4799 Fax +61 7 4633 1796 Email toobranch@nhp.com.au CIRNS 2/1 Bramp Close Portsmith Queensland 4870 Telephone +61 7 6888 Fax +61 7 6999 Email cnsbranch@nhp.com.au NEW SOUTH WLES SYDNEY 34 Day Street North Silverwater New South Wales 2128 Telephone +61 2 9748 3444 Fax +61 2 9648 43 Email sydbranch@nhp.com.au NEWCSTLE 575 Maitland Road Mayfield West New South Wales 2 Telephone +61 2 4960 Fax +61 2 4960 23 Email nclbranch@nhp.com.au SOUTH USTRLI DELIDE 38 Croydon Road Keswick South ustralia Telephone +61 8 8297 9055 Fax +61 8 8371 0962 Email adlbranch@nhp.com.au WESTERN USTRLI PERTH 38 Belmont ve Rivervale Western ustralia 6 Telephone +61 8 9277 1777 Fax +61 8 9277 1700 Email perbranch@nhp.com.au NORTHERN TERRITORY DRWIN 3 Steele Street Winnellie Northern Territory 08 Telephone +61 8 8947 2666 Fax +61 8 8947 49 Email darbranch@nhp.com.au NEW ZELND www.nhpnz.com UCKLND 7 Lockhart Place Mt Wellington uckland Telephone +64 9 276 67 Fax +64 9 276 92 Email sales@nhpnz.com CHRISTCHURCH Gasson Street Sydenham Christchurch Telephone +64 3 377 47 Fax +64 3 377 Email sales@nhpnz.com ELECTRICL ENGINEERING PRODUCTS PTY LTD.B.N 84 004 4 812 Catalogue TB2CT 09/06 Copyright NHP 6