A product made in Australia. Insulated Conductor Rail ACTIV-8 PLUS
|
|
|
- Posy Lyons
- 10 years ago
- Views:
Transcription
1 A product made in Australia Insulated Conductor Rail ACTIV-8 PLUS
2 ACTIV-8 PLUS The Industry Standard in Conductor Rails ACTIV-8 is the most widely used and stocked conductor rail in use in Australia. It was designed by Conductix-Wampfler engineers utilising over thirty years of experience and supported by the worldwide Delachaux group of companies with over fifty years of pioneering innovation in mobile electrification. Across Australia you can find ACTIV-8 used in many applications including overhead cranes, automated storage and retrieval, assembly lines and other moving powered equipment. With the ACTIV-8 range of accessories, the ease of installation and the Conductix-Wampfler team ready to assist in the design of difficult installations, it becomes obvious why ACTIV-8 has become accepted as the industry standard. Some Benefits of the ACTIV-8 PLUS System Current ratings from 90 to 400 Amps Finger safe to IP2 Systems up to 200 m without expansion sections Able to be curved down to a 1.5 m radius Green coloured earth components. Basic System Components Conductor Rails Available in galvanised steel or copper. Supplied in four metre lengths and in a range of 90 to 400 Amps. Factory curved units are offered. Power Feeds Power feeds are designed in a variety of styles ranging from 54 to 330 Amps and available to suit cable sizes up to 70 mm 2. Expansion Sections Expansion sections are used at all structural expansion joints and for long runways to compensate for thermal expansion. Insulating Covers Standard conductor bar covers of PVC meet all requirements for electrical insulation and may be used outdoors. Standard temperature PVC cover rated to 75 C. Medium temperature Lexan cover rated to 120 C. Hanger Clamps / Anchor Clamps Hanger clamps made from high strength Xenoy support the conductors and are of a sliding tight design. Anchor clamps are designed to grip and support the conductors anchor-tight and are used at anchor points only. Collectors Insulated contact heads that hold the replaceable shoes are mounted on spring loaded arms and are designed to both articulate and swivel. No exposed metal surfaces carry current. Basic System Design End cap Splice assembly Expansion assembly Hanger clamp Powerfeed splice assembly 150 mm min 200 mm min Activ-8 conductors 25 mm RHS mounting bar
3 Technical Data Typical 4 Pole System Max. distance from anchor points Max. distance between anchor points Max. distance from anchor point End cap Anchor point Hanger Expansion assembly Anchor point Powerfeed assembly 150 min Splice assembly 4000 mm 500 min X Typical bracket spacing: X = 1500 mm standard mount / X = 1000 mm lateral mount / X = 1000 mm curves An accurate choice of conductors can only be made when all of the following information is known: Type of current: single or three phase AC; continuous DC Expected duty cycle of the system The maximum current load for all motors The ambient temperature range Allowable voltage drop for the motors being supplied Environment (dusty, coastal, humid, acidic ) Galvanised Steel Copper 90 A 120 A 140 A 250 A 400 Cross sectional area in sq mm Weight per four meter length 1.91 kg 2.4 kg 3.26 kg 2.14 kg 3.65 kg Resistance R (for DC) (ohm/m) Impedance Z (Ohm/m) 22 mm 20 C Impedance Z (Ohm/m) 38 mm 20 C * Impedance Z (Ohm/m) 75 mm 20 C Max. system length without expansions 200 m 200 m 200 m 150 m 150 m Max. distance between anchor points 180 m 180 m 180 m 120 m 120 m Max. distance from anchor to end of run 100 m 100 m 100 m 75 m 75 m Min. bending radius 1.5 m 1.5 m 1.5 m 1.5 m 1.5 m Thickness/gauge of conductor in mm * Z bracket arrangement Voltage Drop Calculations AC three phase VD = L x I x Z x 1.73 Volts AC single phase VD = L x I x Z x 2 Volts DC VD = L x I x R x 2 Volts VD = Voltage drop in Volts I = Maximum Current in Amps L = System length in meters from feed R = DC resistance in Ohms per meter Z = Impedance in Ohms per meter The value of L will vary dependent on the placement of the power feed(s) as shown in the diagram below: End Feed L = length Centre Feed L = 1/2 length Two End Feeds L = 1/4 length Feed point at 1/6 from each end L = 1/6 length Feed points at 1/2 and 1/10 from ends L = 1/10 length
4 System Components Conductor Rail Detail Galvanised Steel/Copper Galvanised Steel Copper 90 A 120 A 140 A 250 A 400 Conductor Rail 4 m Conductor Rail 4 m Med. Temp. * Splice Assembly Power Feed End Cover Expansion Section 1.5 m Isolation Section 500 mm 97061/ / / / /400 All components listed above (except Med. Temp. cover) are available in green to designate earth. * Medium Temperature conductor bar incorporates red, halogen-free lexan cover. Standard Mounting Splice Assembly P/No (Copper) / P/No (Galv.) Z Mounting Bracket bare Z Mounting Bracket w/3 hangers Z Mounting Bracket w/4 hangers Galv. & Copper Part No. Description 1 Lug Connected Amps 2 Lugs Connected 98307/06 Power Feed 6 mm 2 Crimp Lug Power Feed Assembly A P/No /10 Power Feed 10 mm 2 Crimp Lug /16 Power Feed 16 mm 2 Crimp Lug /25 Power Feed 25 mm 2 Crimp Lug /35 Power Feed 35 mm 2 Crimp Lug Hanger Clamp P/No Anchor Clamp P/No
5 System Components 100 Amp DI Collector P/No (Phase) / G (Earth) 50 Amp SI Collector P/No (Phase) / (Earth) Contact surface Contact surface 224 Setting height mm - 32 mm Collector effective working environment + 13 mm - 13 mm Collector effective working environment 13 mm square 61 Setting height Customer cable Amp DI / 50 Amp SI Collector Shoe P/No Collector Shoe P/No Includes holder 87 For Double Arm Collector (P/No ) Pick-up Guide Expansion Section Other Components Part No. Description Part No. Description A Collector Shoe A 1 Pole Collector A 3 Pole Collector A 4 Pole Collector Monopole Pick-up Guide Assembly Two Pole Pick-up Guide Assembly Three Pole Pick-up Guide Assembly Four Pole Pick-up Guide Assembly Monopole Isolating Section Two Pole Isolating Section Three Pole Isolating Section Four Pole Isolating Section Conductor Bar PVC Insulating Cover Splice Cover Half Cluster Style Anchor Clamp End Cover mm Collector Mount Bar Cluster Style Monopole Hanger Clamp Cluster Style 3 Pole Hanger Clamp Cluster Style 4 Pole Hanger Clamp Splice Clamp w/o Cover A Power Feed w/o Cover C311 Transfer Cap 98328/70 Power Feed for 70 mm Cable A Cast Iron Cleaning Shoe for collector A Cast Iron Cleaning Shoe for DI + SI collector A163 Danger Live Rail Sign A164 25mm Collector Mount Bar 97879C672 3 Phase Anchor Clamp Kit (incl. Z-Bracket) 97879C671 4 Phase Anchor Clamp Kit (incl. Z-Bracket)
6 KAT-ACTIV-8 PLUS 01 Conductix-Wampfler 2013 Subject to Technical Modifications Without Prior Notice Victoria Head Office 14 England Street, Dandenong, Victoria 3175 Ph: Fax: New South Wales 5/ Victoria Street, Wetherill Park, New South Wales 2164 Ph: Fax: Queensland 45 Millenium Place, Tingalpa, Queensland 4173 Ph: Fax: Western Australia 6/133 Kelvin Road, Maddington, Western Australia 6109 Ph: Fax:
ACTIV-8 PLUS Insulated Conductor Bar
ACTIV-8 PLUS Insulated Conductor Bar A product made in Australia www.conductix.com.au ACTIV-8 PLUS ACTIV-8 is the most widely used and stocked conductor rail in use in Australia. It was designed by Conductix
1 Introduction - Advice... 2. 2 Conductor Rails... 3. 3 Track Coupler... 4. 4 Power feeds... 5. 5 Air Gap Insulation Section... 6
Contents 1 Introduction - Advice... 2 2 Conductor Rails... 3 3 Track Coupler... 4 4 Power feeds... 5 5 Air Gap Insulation Section... 6 6 Expansion joints... 7 7 Anchor Caps... 8 8 End Caps (Distance between
SAFELEC I N S U L A T E D C O N D U C T O R B A R S 6 0 u p t o 1 0 0 0 A m p
I N S U L A T E D C O N D U C T O R B A R S 6 0 u p t o 1 0 0 0 A m p Finger safe up to IP2 60 to 1000 Amp conductors in Standard or Medium Heat Cover shaped to shed water and dust Horizontal conductors
RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo
Connectors, Clamps, Compensating Devices, Insulators and Safety Equipment for Overhead Catenary Lines RAILWAY CATENARY SYSTEMS Components and Systems for the Electrification of Railway Lines. Welcome to
Pressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Conductor Bar Manual 8-Bar
Conductor Bar Manual 8-Bar 963000.2.2 8-BAR MANUAL 1 Conductix Incorporated The technical data and images which appear in this manual are for informational purposes only. NO WARRANTIES, EXPRESS OR IMPLIED,
Festoon 715 P PUR cable for flexible application in festoon systems
CABLES FOR CRANE AND CONVEYOR APPLICATIONS Festoon 715 P PUR cable for flexible application in festoon systems S AB BRÖCKSKES D-VIERSEN Festoon 715 P 1 x 16.0 mm 2 C Marking for Festoon 715 P 07150162:
Electrical Safety Products
Electrical Safety Products Trelleborg Electrical Safety Products A safe working environment is important in all industries, but in the electrical generation and supply industry, it is paramount. Trelleborg
HOW TO CORRECTLY CONNECT DEEP CYCLE BATTERIES AND CHOOSE THE RIGHT CABLE SIZING
HOW TO CORRECTLY CONNECT DEEP CYCLE BATTERIES AND CHOOSE THE RIGHT CABLE SIZING There are several ways to wire multiple batteries to achieve the correct battery voltage or capacity for a particular DC
5.2. Overview. The better method to install solderless compression connectors on power cable
5.2 Overview The better method to install solderless compression connectors on power cable The Thomas & Betts method of installing compression connectors on power cables is designed to provide a high degree
Railtrac 1000. A unique, flexible, multi-purpose system for welding and cutting. G lobal solutions for local customers everywhere
1000 A unique, flexible, multi-purpose system for welding and cutting. G lobal solutions for local customers everywhere 1 SAB Flexible answer to stiff requirements is a system of components that can be
0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S
C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S January 2009 Issue 6 Valu Guide Brackets The Ultimate in Adjustability and Cost Savings Valu Guide brackets are part of a family
Linear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
CDGRD-10. Grounding. Solutions For Comm/Data Applications
CDGRD-10 Grounding Solutions For Comm/Data Applications Overview & Table of Contents Cooper B-Line s Grounding products for rack & runway provide a complete solution for grounding metal supports. The offering
Product Overview Conductor Rails
Product Overview Conductor Rails 2 Conductix-Wampfler Conductor Rails The simple solution! MultiLine 0831 on an electrified monorail system in a brewery Insulated conductor rails are one of the most widely
VCE VET ENGINEERING STUDIES
Victorian Certificate of Education 2013 SUPERVISOR TO ATTACH PROCESSING LABEL HERE STUDENT NUMBER Letter Figures Words VCE VET ENGINEERING STUDIES Written examination Section Wednesday 20 November 2013
PART 1 - INTRODUCTION...
Table of Contents PART 1 - INTRODUCTION... 3 1.1 General... 3 1.2 Sensor Features... 3 1.3 Sensor Specifications (CDE-45P)... 4 Figure 1-1 CDE-45P Sensor Dimensions (standard, convertible style)... 4 PART
Trade of Electrician. Three-phase Distribution Boards And Socket Circuits
Trade of Electrician Standards Based Apprenticeship Three-phase Distribution Boards And Socket Circuits Phase 2 Module No. 2.3 Unit No. 2.3.2 COURSE NOTES Created by Charlie Walsh - Athlone TC Revision
Vario-Series Accessories
Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates
Premolded cable termination, indoors SOT 7.2 kv
Premolded cable termination, indoors SOT 7. kv cables 1- or 3-core with Al or Cu conductor for 6.6/7. kv, indoors. t can also be installed in an indoor humid environment*. s CENELEC, HD 69.1 S1 integrated
White paper. SACE Tmax XT Circuit-Breaker Terminals and Connection
White paper SACE Tmax XT Circuit-Breaker Terminals and Connection Circuit-Breaker Terminals and Connections Index Introduction... 2 1. Components used for wiring... 3 1.1. Electrical...3 1.2. Flexibility
ELECTRIC METERING COMMERCIAL & INDUSTRIAL
ELECTRIC METERING COMMERCIAL & 1.0 INDEX 1.0 INDEX 2.0 SCOPE 3.0 GENERAL REQUIREMENTS 4.0 METER LOCATIONS 5.0 UNDERGROUND TERMINATIONS 6.0 METERING TRANSFORMER ENCLOSURES 7.0 SINGLE CUSTOMER METER INSTALLATIONS
Section 21. Telecommunication Hardware. www.geindustrial.com BuyLog Catalog 21-1
Introduction...21-1 Fiber Closure Hardware...21-2 Cable Location Surge Protectors...21-4 Introduction GE has been manufacturing Telecommunication Hardware products for over 20 years and has become a leader
High Power Connectors for Power Supply and Power Circuits
Introduction Silver Plated Power Contacts with Contact Springs for Maximum Performance in Exposed Applications The demand for shortest possible periods of machine shut-downs and assembly times requires
Aluminium Standard. Technical Data. Included in delivery
luminium Standard UL / cul Robust aluminium enclosure for mechanical engineering and automation technology Fixing options for s and mounting plates Usable in wide temperature area Technical ata aterial:
IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig
Through hollow shaft Ø 5 bis 4 mm Outside diameter only 76 mm Easy installation by means of clamping ring front or rear Operating temperature up to 00 C Applications: motors, printing machines, lifts NUMBER
AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle
Scope This specification stipulates the minimum requirements for mechanically linked three-phase electronic sectionalizers, for use on outdoor medium voltage overhead lines of 15, 27, and 38 kv. Electronic
Gulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES XLPE INSULATED 600/1000V CABLES Two Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 1 Three Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC 2 Four Core Cables CU/XLPE/PVC/LC/PVC/SWA/PVC
EARTHING SYSTEM CALCULATION
BAZIAN STEAL FACTORY S/S 132/11kV, 1x30/40MVA EARTHING SYSTEM CALCULATION Kurdistan Region Sulaimani May 2011 Bazian Steal Factory S/S 132/11kV, 1x30/40 MVA Contents: 1. Introduction... 3 2. List of references
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
Series 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings
*** Provide this document to the inspector along with ALL system installation instructions *** Project Address: Scope: Standard plan for the installation of grounded microinverter solar PV systems, not
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
BL-DBK150A DUAL BATTERY 12v 150 AMP SMART SYSTEM
BL-DBK150A DUAL BATTERY 12v 150 AMP SMART SYSTEM Waterproof and Shockproof Easy DIY Dual Battery System BL-DBK150A Supplied Parts List Parts List 1 x 12v 150Amp Electronic Dual Battery Smart Controller
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
Rittal TopTherm fan-and-filter unit
Rittal TopTherm fan-and-filter unit System Climate Control More pressure. Higher air flow rates. 2 Assembly without tools Straightforward assembly, exchange and maintenance with no need for tools of any
FABA 100 Insulated Conductor System. Mounting Instructions. Fon: +49 (2307) 704 0 Fax: +49 (2307) 704 444 E-Mail: [email protected]
Insulated Conductor System s Seite 1 Page 3 System Contents Page Introduction 4 Hanger Clamp (Stud-mounting with spring clip) 6 Hanger Clamp (Clip-type) 7 Conductor Rails 8 Conductor Rails Shortening 8
INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate
Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide
Instruction Bulletin EAV85226 08/2014 Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide Retain for future use. Product Description Kit Contents The Wiser Panel Meter is for use in energy management
STREETLIGHT SYSTEM GROUNDING AND BONDING
Page: 1 of 8 STREETLIGHT SYSTEM GROUNDING AND BONDING 1. Scope This Construction Standard covers the grounding and bonding requirements for single phase streetlight systems served by the Looped Radial
5SV Residual Current Protective Devices
s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective
PROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN
for PROFIBUS-PA and -DP 10/63-6.46 EN CPN 080/CPE 080-Ex PROFIBUS-PA basis cable AWG 18, 0.88 mm 2 Use For fixed installation indoor and outdoor, on racks and in conduits. Application Fieldbus cable for
Chemical resistance Accidental
Industrial flexible cable, insulation and outer sheath in elastomer Description Application TITANEX flexible cable is intended for installations with moving equipment, electric appliances and for building
EUPEN Cable Inc. North & South America
toronto EUPEN Cable Inc. North & South America Bethlehem, PA dallas, tx Mexico city Tampa Bay EUPEN CABLE INC. Table of Contents ELLIPTICAL WAVEGUIDE and Connectors.................................................5
NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES
NIVOCONT CONDUCTIVE LEVEL SWITCHES O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL SWITCHES APPLICATION Level switches, based on the conductivity principle, can be applied to liquids with conductivity
MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
ATS Overhead Table Shelf System INSTRUCTION MANUAL
ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship
Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications
Dialight Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications Case Study: Rockline Case Study (Manufacturing)
Cables. Accessories. For Force, Torque and Strain Sensors
Accessories Cables For Force, Torque and Strain Sensors Charge mode, high impedance piezoelectric measurement demands highly insulated coaxial cables and connectors to ensure an insulation resistance greater
6 ELECTRICAL PARAMETERS
6 ELECTRICAL PARAMETERS For power, low voltage and medium voltage cables, cross section nominal areas are calculated in taking into account several parameters as: permissible current carrying capacities
Linear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium
STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
Geberit Pluvia. Syphonic roof drainage system. Overview Page 42. Geberit Pluvia outlets 6 l. Geberit Pluvia outlets 14 l
Geberit Pluvia Syphonic roof rainage system Description Overview Page 42 Geberit Pluvia outlets 6 l Outlets Page 43 Contact foil Page 43 Outlets Page 44 Geberit Pluvia outlets 14 l eating element Page
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
Odyssey of the Mind Technology Fair. Simple Electronics
Simple Electronics 1. Terms volts, amps, ohms, watts, positive, negative, AC, DC 2. Matching voltages a. Series vs. parallel 3. Battery capacity 4. Simple electronic circuit light bulb 5. Chose the right
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
Comparative study for cables and busbars
Comparative study for cables and busbars Preliminary considerations To compare the prices of two categories of product as different as traditional cables and busbars, it is necessary to make some preliminary
LC/LCD ranges level controllers
GRUNDFOS WASTEWATER LC/LCD ranges level controllers 18 Grundfos Sololifts > Grundfos LC/LCD controllers Keeping a close eye on liquid levels Reliable level controllers from Grundfos Grundfos offers a choice
Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
CHAPTER 4 DESIGN OF INTEGRAL SLOT AND FRACTIONAL SLOT BRUSHLESS DC MOTOR
47 CHAPTER 4 DESIGN OF INTEGRAL SLOT AND FRACTIONAL SLOT BRUSHLESS DC MOTOR 4.1 INTRODUCTION This chapter deals with the design of 24 slots 8 poles, 48 slots 16 poles and 60 slots 16 poles brushless dc
A technical guide to Shell tactic emv
A technical guide to Shell Tactic EMV TABLE OF CONTENTS SECTION PAGES Introduction 3 Benefits of Short Re-Lubrication Intervals 5 Contamination Prevention Strategies 6 Workplace Safety and Efficiency Gains
GROENEVELD AUTOMATIC GREASING SYSTEMS
GROENEVELD AUTOMATIC GREASING SYSTEMS TWIN Parts & Accessories Book Pumps, Fittings, Injectors, Lining, etc. www.groeneveld-group.com 1 TWIN ELECTRICAL Item Part # Description 1 F113966 Switch 24V 2 F122991
TELESCOPE Motorized Lighting Suspension
TELESCOPE Motorized Lighting Suspension Mod. 8400 FEATURES The De Sisti TELESCOPE is a single point suspension specifically designed to provide rigidity and stabilization of all moving parts. It can extend
EARTHING AND BONDING AT SECONDARY SUBSTATIONS
DISTRIBUTION CONSTRUCTION MANUAL SECTION 4 - SUBSTATIONS ISSUE B SEPT 1996 4.4.4 EARTHING AND BONDING AT SECONDARY SUBSTATIONS 1 SCOPE This section of the Distribution Construction Manual lays down the
Model 1210C Battery Powered Pump Shown. Description
12 Volt DC Rotary Vane Pump Series 1200C Model 1210C Battery Powered Pump Shown Description of Included Models Model Number FR1205C FR1210C FR1211C FR2410C FR2411C Description Basic 12 volt DC pump with
TECHNICAL DATASHEET Incremental Encoder RI 58-H
Through hollow shaft High accuracy by means of integrated flexible coupling Safe shaft mounting Applications: textile machines, motors, drives, copiers NUMBER OF PULSES 1 / 2 / 3 / 4 / 5 / 10 / 15 / 20
STEWART GILL CONVEYORS Ltd
STEWART GILL CONVEYORS Ltd 550M STS SYSTEM overhead - inverted - side mounted - floor mounted - SPECIALISTS IN OVERHEAD CONVEYOR SYSTEMS 2 Index About 550M STS... 3 Track... 4 Track Supports... 5 Bends...
This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.
1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. The unit will start automatically. Please pay particular
Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules
CHIEF EN TERPRISES INC. M a s t e r I n t e r n a t i o n a l D i s t r i b u t o r Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules M AS TER IN
Command devices Pull-wire emergency stop switches One-side operation ZS 71 range 6.1 6.1.1 6.1.1.1. 312 Schmersal -10 0 10 20 30 40 50 60 70 T [] C
.1.1.1 One-side operation ZS 71 range 40 30 ø10 10 53,5(63)* 6 8 18 24 105 33 56 12 22 M20x1,5 52 17,5 42 15 Features To EN 418 / IEC 60947-5-5 Metal enclosure 2 contacts Small body 2 cable entries M20
ADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
7000 Series Buccaneer
The all plastic and metal construction of the - circular that combine the ease of use of a quick coupling mechanism with proven environmental sealing for signal and mains power. Designed and independently
ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM
ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM MAKING SMART TOWNS, BUILDING SMART COMMUNITIES WHY PANASONIC? RESIDENTIAL STORAGE BATTERY SYSTEM The next evolution in solar energy solutions. Panasonic
Submit shop drawings for equipment provided under this section Shop drawings shall indicate:
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,
Thru-Beam 80 to 320 mm 0.05 to 0.08 mm
Series 7069A Fiber Optics The 7069A coupled with the appropriate cable forms a fiber optic sensor controller system capable of detecting objects as small as 0.01mm dia. and color marks on backgrounds of
1. Description. 2. List of Accessories included A B C F G H
1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin. The unit will start automatically. Please pay particular attention to the following: Possible danger to
SERIES 1800 - SINGLE POLE AND DOUBLE POLE ROCKER SWITCHES UP TO 12 (4) A 250 V~ AND 8 (8) A 250 V~
SERIES 1800 - SINGLE POLE AND DOUBLE POLE ROCKER SWITCHES UP TO 12 (4) A 250 V~ AND 8 (8) A 250 V~ PRODUCT ADVANTAGES Switching principle with long life endurance due to a low friction contact system (ball),
Circuit Breakers. Next Generation of Protection Capabilities
Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many
NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 05 26 GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS
SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS RELATED SECTIONS: Section 27 00 00 General Requirements Section 27 02 00 Communication General Requirements Section 27 05 28 Pathways for Communications
Cable/Conduit Conversion
Cable/Conduit Conversion Busway can be used in many applications where cable and conduit are more commonly used. The question arises, Why use busway instead of conventional cable and conduit? Benefits
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
Valu Guide Sheaths. Valu Guide Inserts. Optional Valu Guide Inserts. Typical Properties of Valu Guide Rail. and Hardware.
14 gauge stainless steel The Original, Long Life Sanitary Guide Rail Valu Guide rail incorporates two outstanding materials: stainless steel and UHMW. The 14 ga. stainless steel sheath provides rigid streamlined
RY2 miniature industrial relays
6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,
Features. Picture. Specifications
Type: for level measurement Order No.: see Table 1 / Page 4 Features Picture Two wire system Piezoresistive measuring element Output signal 4-20 ma Conformity error ±0.5 % FS or Standard DIN measuring
All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.
DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,
Description. Outlets Page 62. Contact foil Page 65. Accessories Page 65. Outlets Page 68. Accessories Page 69. Brackets Page 73.
Pluvia Syphonic roof rainage system Description Outlets Page 62 Pluvia outlets 12 l Contact foil Page 65 Accessories Page 65 Pluvia outlets 25 l Outlets Page 68 Accessories Page 69 Pluvia outlets 45/60/100
E2 Series Electric Furnaces
E2 Series Electric Furnaces Service Manual Table of Contents Electrical Requirements... 10 Codes, Specifications Requirements... 10 Connection Supply Service Wires... 10 Furnace Sequence of Operation...
HDA -----------------------------------------------------------
----------------------------------------------------------- Lightstrips ---------------------------------------------------------------------- Ceiling system for heating and cooling LIGHTSTRIPS LIGHTSTRIPS
3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,
Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41
Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)
Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall
IMPORTANT DOCUMENTATION DO NOT DISCARD!
PART NO.: 6441-263C SERIES GRT 3 JAW PARALLEL GRIPPERS INFORMATION SHEET IMPORTANT DOCUMENTATION DO NOT DISCARD! Use this information sheet to assist with gripper installation and setup. File with maintenance
Sebastian Knödler Technologie, Rosenstraße 25, D-71549 Auenwald [email protected] Tel.: +49 (0)7191-933 97 91 / Fax: +49 (0)7191-933 97 92
Catalog With pricing in Euro incl. 19% VAT Status: January 2015 Index Lambda-Messwandler V4.0... 2 Wideband-Lambda Controller for 12Volt Supply... 4 Wideband-Lambda Controller for 24Volt Supply... 6 Accessories...
Standard Buccaneer - Ethernet
IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
