Manual motor protectors Type MS32 MS32-1.0 Manual motor protectors Type MS32 Thermal setting Single-phase 3-phase Catalog List range horsepower ratings 1 horsepower ratings number price (Amps) 120V 240V 240V 480V 600V 0.10 0.16 MS32-0.16 0.16 0.2 MS32-0.2 $ 144 0.2 0.40 MS32-0.40 0.40 0.63 MS32-0.63 0.63 1.0 1/2 1/2 MS32-1.0 1.0 1.6 1/10 3/4 3/4 MS32-1.6 1.6 2. 1/6 1/2 1 1. MS32-2. 16 2. 4.0 1/8 1/3 1 2 3 MS32-4.0 4.0 6.3 1/4 1/2 1. 3 MS32-6.3 6.3 9.0 1/3 1 2. 7. MS32-9.0 9.0 12. 1/2 2 3 7. 10 MS32-12. 192 12. 16 1 2. 10 10 MS32-16 16 20 1. 3 10 1 MS32-20 211.0 20 2 2 3 7. 1 20 MS32-2 223.0 MS32 UL File #E137861 Accessories UL File #E9033 Single phase motor ratings are based upon wiring all three poles in series. Discount schedule MA
Type MS32 UL 08E Manual motor protectors MS32-1.0 Manual motor protectors Type MS32 Thermal setting Single-phase 3-phase Catalog List range horsepower ratings 1 horsepower ratings number 2 price (Amps) 120V 240V 240V 480V 600V 0.10 0.16 MS32-0.16E 0.16 0.2 MS32-0.2E $ 223 0.2 0.40 MS32-0.40E 0.40 0.63 MS32-0.63E 0.63 1.0 1/2 1/2 MS32-1.0E 1.0 1.6 1/10 3/4 3/4 MS32-1.6E 1.6 2. 1/6 1/2 1 1. MS32-2.E 244 2. 4.0 1/8 1/3 1 2 3 MS32-4.0E 4.0 6.3 1/4 1/2 1. 3 MS32-6.3E 6.3 9.0 1/3 1 2. 7. MS32-9.0E 9.0 12. 1/2 2 3 7. 10 MS32-12.E 271 12. 16 1 2. 10 10 MS32-16E 16 20 1. 3 10 1 MS32-20E 290 20 2 2 3 7. 1 20 MS32-2E 302 MS32 UL File #E137861 Accessories UL File #E9033 Class 10 overload Short circuit rating of 18kA 1 Single phase motor ratings are based upon wiring all three poles in series. 2 Part includes MMP, barrier and trip signal. Discount schedule MA
Manual motor protectors Type MS32 Accessories MS32-HK11 Auxiliary contact blocks for Type MS32 (side mount) Auxiliary contact blocks for Type MS32 (front mount) Bell alarm contact blocks for Type MS32 1 NO & 1 NC MS32-HK11 2 NO MS32-HK20 $ 33 2 NC MS32-HK02 1 NO & 1 NC MS32-HKF11 2 NO MS32-HKF20 1 NO MS32-SK10 1 NC MS32-SK01 $ 33 $ 33 MS32-HKF11 Shunt trips for Type MS32 110 240 VAC/VDC, 60 Hz MS32-ST110 24 60 VAC/DC, 60 Hz MS32-ST24 $ 82.0 MS32-UA24 Undervoltage trip for Type MS32 24V MS32-UA24 48V MS32-UA48 60V MS32-UA60 110V MS32-UA110 $ 82.0 230V MS32-UA230 400V MS32-UA400 41V MS32-UA41 480V MS32-UA480 Remote control unit MS32-AS Electrically operated remote control unit for MS32. For use up to MS32-16 and below. Not for use with MS32-20 & MS32-2. Provided with 1 NO & 1 NC auxiliary contacts and 1NO trip signal contacts NOTE: May not be used with HFK, SK, ST or UV accessories 24V AC/DC RC32-24V 48V AC/DC RC32-48V 60V AC/DC RC32-60V $ 16 110V AC/DC RC32-110V 230V AC/DC RC32-230V MS32-SA1 MS32-SA3 Supporting terminal for Type MS32 for UA or as N/LS clamp MS32-AS $ 1 Padlocking devices for Type MS32 Adapter for padlock type SA1 MS32-SA1 $ 1.00 Complete padlock kit (includes adaptor, padlock & 3 keys) MS32-SA3 37.0 Discount schedule MA
Type MS32 Accessories Manual motor protectors Switch cublicle mounting kit Molded plastic enclosures for Type MS32 Item Protection Catalog List description level number price Light gray enclosure with black handle IP64 OTPA32B2P1 $ 7 Light gray enclosure with red/yellow handle IP64 OTPA32A2P1 7 Gray enclosure w/clear lid, 4 module IP 12644 84 Gray enclosure w/clear lid, 6 module IP 12646 98 Gray enclosure with black handle IP6 IB32-G 7 Yellow enclosure with red handle IP6 IB32-Y 7 NOTE: Use Discount schedule MA for IP64 & IP6 enclosures; use Discount schedule CB8 for IP enclosures. Plastic adaptors for enclosures for Type MS32 PG16 TO 1/2 NPT PG16-1/2 NPT $ 10 MS32-BB1 MS32-SM1 PS3-2-0 PS3-4-0 Selector handles for through-the-door operation for Type MS32 1 Shaft coupler MSMN $ 1 NEMA 1, 3R, 12 black selector handle OHB2AJ 30 NEMA 1, 3R, 12 red/yellow selector handle OHY2AJ 30 4.1 length shaft OXSX10 4 7.1 length shaft OXSX180 6 NOTE: Use Discount schedule MA for shaft coupler; use Discount schedule H6 for handles and shafts. Power feed terminal blocks for Type MS32 Busbars for Type MS32 2 Standard, accepts 4 AWG wire MS32-SM1 $ 24 Low profile, accepts 4 AWG wire MS32-BB1 2.0 for 2 devices; without auxiliary switch PS3-2-0 $ 24 for 3 devices; without auxiliary switch PS3-3-0 30 for 4 devices; without auxiliary switch PS3-4-0 33 for devices; without auxiliary switch PS3--0 39 for 2 devices; with 1 auxiliary switch PS3-2-1 30 for 3 devices; with 1 auxiliary switch PS3-3-1 34.0 for 4 devices; with 1 auxiliary switch PS3-4-1 37.0 for devices; with 1 auxiliary switch PS3--1 42 for 2 devices; with 2 auxiliary switches PS3-2-2 30 for 4 devices, with 2 auxiliary switches PS3-4-2 37.0 Busbars can be daisy chained to connect additional MS32s. Close coupling adapters Device MS32 + B6/B7 contactor MS32 + VB6/VB7 reversing contactor Catalog number BEA7/32 MS32-VB7 List price $ 12.00 MS32 + A9, A12, A16 contactor BEA16/32 13.0 MS32 + A26 contactor BEA26/32 1.00 AL9 - AL16 BEA16/32AL 14.0 AL26 BEA26/32AL 16.00 MS32 coupled to mini-contactor UL 08 Type E Accessories Required Device Catalog number List price Line side infeed block S3-M3 $ 30 Short circuit trip signal CK-11 49 1 Must have shaft coupler, handle and shaft for through-the-door operation. 2 UL file # E16720; CSA file# LR98427M7-11
Manual motor protectors Technical data Type MS32 Short circuit ratings Short circuit ratings MS32 Group installation short circuit ratings 480V 1 600V 2 Short Circuit Maximum Fuse Range rating size ka, 600VAC A 0.1-0.16 1 0.16-0.2 1 0.2-0.40 1 0.40-0.63 1 0.63-1.0 1 1.0-1.6 1 1.6-2. 1 2. - 4.0 1 4.0-6.3 2 6.3-9.0 3 9.0-12. 0 12. - 16 60 16-20 80 20-2 100 MS32 ka 30 ka 0 ka 8kA Current Fuse MCCB Fuse MCCB Fuse MCCB Fuse range A A A A 0.1-0.16 1600 S7H1200 1600 S7H1200 1600 S7H1200 1600 0.2-0.40 1600 S7H1200 1600 S7H1200 1600 S7H1200 1600 0.40-0.63 1600 S7H1200 1600 S7H1200 1600 S7H1200 1600 0.63-1.0 1600 S7H1200 1600 S7H1200 1600 S7H1200 1600 1.0-1.6 1600 S7H1200 1600 S7H1200 1600 S7H1200 1600 1.6-2. 1600 S7H1200 1600 S7H1200 1600 S7H1200 1600 2. - 4.0 1600 S7H1200 1600 S7H1200 1600 S7H1200 1600 4.0-6.3 1600 S7H1200 1600 S7H1200 600 S7H1200 6.3-9.0 1600 S7H1200 1600 S7H1200 600 S7H1200 9.0-12. 1600 S7H1200 1600 S7H1200 400 S4H20 12. - 16 1600 S7H1200 1600 S7H1200 400 S4H20 16-20 1600 S7H1200 1600 S7H1200 400 S4H20 20-2 1600 S7H1200 1600 S7H1200 400 S4H20 0.1-0.16 1200 S7H1200 1200 S7H1200 1200 S7H1200 0.2-0.40 1200 S7H1200 1200 S7H1200 1200 S7H1200 0.40-0.63 1200 S7H1200 1200 S7H1200 1200 S7H1200 0.63-1.0 1200 S7H1200 1200 S7H1200 1200 S7H1200 1.0-1.6 1200 S7H1200 1200 S7H1200 1200 S7H1200 1.6-2. 1200 S7H1200 1200 S7H1200 1200 S7H1200 2. - 4.0 1200 S7H1200 1200 S7H1200 1200 S7H1200 4.0-6.3 1200 S7H1200 1200 S7H1200 1200 S7H1200 6.3-9.0 1200 S7H1200 1200 S7H1200 20 S4H20 9.0-12. 1200 S7H1200 1200 S7H1200 12. - 16 1200 S7H1200 1200 S7H1200 16-20 1200 S7H1200 20 S4H20 20-2 1200 S7H1200 20 S4H20 1 Fuse: Rated 1600A, Listed Class L. All others, listed RK. Both time delay fuses. 2 Fuse: Rated 1600A, Listed Class L. All others, listed K. Both time delay fuses.
Technical data Type MS32 Short circuit protection Manual motor protectors Short-circuit protection MS32 Setting ranges, short-circuit strength and max. back-up fuses Maximum rated current of the short-circuit fuses if I at at at at at from to 230 V AC 400 V AC 440 V AC 00 V AC 690 VAC I cs gl, am I cs gl, am I cs gl, am I cs gl, am I cs gl, am ka A ka A ka A ka A ka A A A Fuse types: Diazed, l.v.h.b.c., utilisation categories: gl, am (VDE), gl/gg (IEC) Setting ranges 0.1... 0.16 to Short-circuit proof 1.0... 1.6 No back-up fuse required up to I cc = 100 ka 1.6... 2. 40 2 2.... 4.0 60 3 / 40 10 40 cc > I cs 4.0... 6.3 70 0 40 0 7 40 6.3... 9.0 0 80 30 80 0 9.0... 12. 7 80 4 80 27 80 4. 0 12.... 16.0 60 100 40 100 2 100 4 0 16.0... 20.0 100 3 100 22 100 3. 0 20.0... 2.0 0 12 30 12 20 12 3 0 Short-circuit protection MS32 Setting ranges, short-circuit strength and max. back-up fuses Setting ranges 0.1... 0.16 Maximum rated current of the short-circuit fuses if I cc > I cs at at at at at from to 230 V AC 400 V AC 440 V AC 00 V AC 690 VAC I cs gl, am I cs gl, am I cs gl, am I cs gl, am I cs gl, am ka A ka A ka A ka A ka A A A Fuse types: Diazed, l.v.h.b.c., utilisation categories: gl, am (VDE), gl/gg (IEC) to Short-circuit proof 1.0... 1.6 No back-up fuse required up to I cc = 0 ka 1.6... 2. 40 2 2.... 4.0 60 3 / 40 10 40 4.0... 6.3 40 0 7 40 6.3... 9.0 30 80 0 9.0... 12. 4 80 27 80 4. 0 12.... 16.0 40 100 2 100 4 0 16.0... 20.0 3 100 22 100 3. 0 20.0... 2.0 30 12 20 12 3 0 I cs = Rated service short-circuit breaking capacity, I cu = Rated ultimate short-circuit capacity, I cc = Prospective short-circuit current at installation location. I cs = I cu in the case of MS 32 and MS 116!