Compressor Technology / Type and its Impact on GWP

Similar documents
A Comparison of an R22 and an R410A Air Conditioner Operating at High Ambient Temperatures

Troubleshooting an Air Conditioning system. R D Holder Eng. Roger D Holder MSME

Scroll compressors for Low GWP Heat Pumps using R290 natural refrigerant. Pierre Ginies, Next Heat Pump Generation 2015

TEST REPORT #44. System Drop-in Tests of Refrigerant R-32 in Single Packaged Vertical Heat Pump (SPVH)

Todd M. Rossi, Ph.D. President

Characteristics of Evaporators

Geothermal Alliance of Illinois. TXVs Theory and Fundamentals John Haug Senior Application Engineer Emerson Climate Technologies - Flow Controls

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application

Chapter 3.4: HVAC & Refrigeration System

Air Conditioning System

MAC-120HE-01 Air-Cooled Chiller

IV. Rear Mount System

Impacts of Refrigerant Charge on Air Conditioner and Heat Pump Performance

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

Development and testing of a multi-type air conditioner without using AC inverters

Testing methods applicable to refrigeration components and systems

UNIT 2 REFRIGERATION CYCLE

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.

Repair, Retrofit, or Replace Choices for Servicing R-22 Equipment

Troubleshooting HVAC/R systems using refrigerant superheat and subcooling

PG Student (Heat Power Engg.), Mechanical Engineering Department Jabalpur Engineering College, India. Jabalpur Engineering College, India.

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

HVAC SYSTEM (HEATER, VENTILATOR, AND A/C)

Model-Based Approach for Optimizing a Data Center Centralized Cooling System

Experimental and Modeling Investigation of Two Evaporator Automotive Air Conditioning Systems

How To Design A Refrigeration System

Refrigeration Compressed Air Dryer Buran Ultrapulse

Waste Heat Recovery through Air Conditioning System

Comparing Air Cooler Ratings Part 1: Not All Rating Methods are Created Equal

Refrigeration Basics 101. By: Eric Nelson

Air Conditioning 101. STN Presentation AC101

Glossary of Heating, Ventilation and Air Conditioning Terms

DESIGN OF AIR CONDITIONING SYSTEM IN AUTOMOBILE

A/C refrigerant system, overview

System Diagnosis. Proper vehicle diagnosis requires a plan before you start

GEOMETRIC, THERMODYNAMIC AND CFD ANALYSES OF A REAL SCROLL EXPANDER FOR MICRO ORC APPLICATIONS

Any Service Technician Can Fix It A Good Service Technician Can Figure Out What s Wrong With It.


Certified HVAC Audit Report Key Takeaways and Implications. Created for: Pets On the Go 445 Logging Road, Building 3 Yardley, PA-19034

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

TEST REPORT #31. System Drop-in Test of Refrigerant R-32 in Split Air-conditioning System

Regency TAFE, SA. An evaluation of the effects of PermaFrost treatment on a Fujitsu Heat Pump. July Prepared by

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

Over 30% 2-40 TR. Air Conditioning Danfoss compressors For comfort and precise cooling. energy savings

Preventive Maintenance Strategies and Technologies Can Pave the Path for Next Generation Rooftop HVAC systems

Structure of this presentation

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM WITH R404A, R407C AND R410A

UNDERSTANDING REFRIGERANT TABLES

42-Volt Electric Air Conditioning System Commissioning and Control For a Class-8 Tractor

3Aftermarket Systems. Air Conditioners and Kombos Heater/Pressurizer System Matrix Aftermarket System Requirements...

HEATER, AIR CONDITIONING AND VENTILATION

Why and How we Use Capacity Control

Dehumidification Frequently Asked Questions

Heat Recovery In Retail Refrigeration

How To Understand Evaporator

Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems

COMMERCIAL HVAC EQUIPMENT. Condensers and Cooling Towers

2004 Standard For Performance Rating Of Positive Displacement Refrigerant Compressors And Compressor Units

Development of CO 2 A/C System

Test Report issued under the responsibility of:

THEORETICAL AND EXPERIMENTAL EVALUATION OF AUTOMOBILE AIR-CONDITIONING SYSTEM USING R134A

MAXIMUM HEAT LOAD TEMPERATURE TESTING ( Differential Temperature Testing )

SERVICE MANUAL OUTDOOR UNIT MUZ-A09NA,- 1,- U1,- U2 MUZ-A12NA,- U1 MUZ-A15NA,- U1 MUZ-A17NA,- U1 MUY-A15NA MUY-A17NA MUY-A24NA,- 1,- U1,- U2

Increasing the evaporation temperature with the help of an internal heat exchanger

ECOCIAT. Domestic hot water heat recovery unit

New Trends in the Field of Automobile Air Conditioning

Inverter and programmable controls in heat pump applications

Solenoid valves Type EVU

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Low GWP Replacements for R404A in Commercial Refrigeration Applications

How To Know If A Refrigeration System Is Efficient

AIR CONDITIONING LIFE EXTENDER ACX10 FIELD INSTALLATION AND PERFORMANCE EVALUATION

SERVICE MANUAL MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA MUZ-GE18NA MUZ-GE24NA MUY-GE09NA MUY-GE12NA MUY-GE15NA MUY-GE18NA MUY-GE24NA OUTDOOR UNIT

Commercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1:

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

Rating Water-Source Heat Pumps Using ARI Standard 320 and ISO Standard

Refrigerant System for Vehicle Air- Conditioning NISSAN / ZEXEL. Phoenix Alternate Refrigerant Forum June,28----July,1 Phoenix, AZ

Electronically Controlled Clutchless or Variable Drive Compressors

RESEARCH HIGHLIGHT. Performance Assessment of a Cold-Climate Air Source Heat Pump

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER + SAP C181MA + SAP C181GA + SAP C181BA + SAP C241MA + SAP C241BA FILE NO.

Update on a Low GWP Refrigerant: Fluid H

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

HVAC-02, Air Conditioning Troubleshooting and Repair

AIR CONDITIONER GENERAL 1. SPECIFICATIONS AIR CONDITIONER REXTON

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

ANNEX 1. Analysis of scientific literature

Central Air Conditioning Plants

Product Catalog. Large Commercial Split System. Model RAUP - TTV MBH CFM 50 Hz

HVAC Basic Science - System Capacity

Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

Accessories Catalog Air-Conditioning Solutions. For Trucks, Light-duty Vehicles, Mini / Midi Buses and Special Vehicles

Silicagel-water adsorption cooling prototype system for mobile air conditioning

ECM Motors Manufactured By Regal Beloit. Products and Applications- What s an ECM? GEXPRO Regal Beloit s distribution arm for all ECM motor products

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

Adjustment Data MAZDA Comprex D - RF-CX

How To Design A Building In New Delhi

ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE

Transcription:

Compressor Technology / Type and its Impact on GWP Sanden International (U.S.A.) Inc. Presented by : Jacob Bayyouk SAE 8 th Alternate Refrigerant Systems Symposium July 17 19, 2007 Scottsdale, Arizona 1

Compressor Technology / Type and its Impact on GWP Contents Chapter 1: Introduction Chapter 2: Test Description Chapter 3: Results & Conclusions Chapter 4: Further Analysis Beyond IMAC Chapter 5: Appendix 2

Compressor Technology/Type and its Impact on GWP Contents Chapter 1: Introduction Chapter 2: Test Description Chapter 3: Results & Conclusions Chapter 4: Further Analysis Beyond IMAC Chapter 5: Appendix 3

Compressor Technology / Type and its Impact on GWP Introduction Several Compressor Technologies were evaluated for their impact on vehicle power consumption. All evaluations were conducted on a system calorimeter consistent with IMAC test conditions. Annualized Energy Consumption values were calculated based on the established IMAC weighting factors. Sanden Scroll Compressors TRSA09 (w/o Oil Separator) & TRSE07 (w/ Oil Separator) were compared vs. Fixed Swash Plate (w/ Oil Separator) Compressor and Internally Variable Swash Plate (w/ Oil Separator) Compressor. 4

Introduction - Scroll Compression Process Suction Re-expansion Orbiting Scroll Scroll Indicator diagram Fixed Scroll Compression Pressure Discharge 0 Crank Angle 2π Compression 5

Introduction - TRSA/E Cross Sectional View TRSA Oil Separator TRSE 6

Compressor Technology / Type and its Impact on GWP Contents Chapter 1: Introduction Chapter 2: Test Description Setup & Test Conditions Data Management Charge Determination TXV Confirmation Chapter 3: Results & Conclusions Chapter 4: Further Analysis Beyond IMAC Chapter 5: Appendix 7

Test Setup - Component Information Production system with the latest condenser and evaporator technologies (i.e. micro-channel type) was chosen for the evaluation. Components Evaporator Condenser TXV Compressors Sanden TRSE07 Sanden TRSA09 D IVD14 A FD17 Micro-Channel, IRD 79 tubes 520mm Height / 630mm Length / 15mm Depth 1.0 ton, cross charge Fixed disp. scroll w/ oil separator (77 cc) Fixed disp. scroll (86 cc) Description Micro-Channel 42 tubes 286mm Height / 280mm Length / 41mm Depth Internally variable disp. Swash plate w/ oil separator (135 cc max) Fixed disp. swash plate w/ oil separator (177 cc) 8

Test Setup System Bench HVAC Room Condenser Room 9

Test Setup System Bench Evaporator 10

Test Setup - Instrumentation and Data Sampling List of data Channels Refrigerant Side Compressor inlet pressure & temperature Compressor outlet pressure & temperature TXV inlet pressure & temperature Evaporator outlet pressure & temperature Refrigerant oil circulation rate (O.C.R.) Refrigerant mass flow rate Air Side Supply air temperature & humidity (evap. and cond.) Supply air mass flow (for both evap. and cond.) 3 thermocouple-grid at HVAC module outlet nozzle Temperature / Humidity combo sensor at the center of HVAC module outlet nozzle Other Compressor speed Compressor drive torque & speed Blower voltage Clutch voltage Steady State Cycling Test Data Sampling Rate Every 5 sec for 10 mins. Every 0.1sec for Shaft torque, RPM, Clutch voltage HVAC out air temp. & humidity Every 5 sec for other channels All data recorded over a period of 10 mins. 11

Test Conditions IMAC test matrix & annual weighting factors Test# Comp speed RPM Cond Air Temp o F Cond Air flow SCFM Evap Air Temp o F Evap Air R H % Evap Airflow SCFM IMAC Weighting Climate wt. RPM Wt I45 L45 M45 H45 I35a L35a M35a H35a I25a L25a M25a H25a I15 L15 M15 H15 900 1500 2500 4000 900 1500 2500 4000 900 1500 2500 4000 900 1500 2500 4000 113 113 113 113 95 95 95 95 77 77 77 77 59 59 59 59 725 1460 2260 2260 725 1460 2260 2260 725 1460 2260 2260 725 1460 2260 2260 95 95 95 95 95 95 95 95 77 77 77 77 59 59 59 59 25 25 25 25 40 40 40 40 80 80 80 80 80 80 80 80 230 275 275 275 230 275 275 275 190 127 127 127 127 85 85 85 0.2% 0.2% 0.2% 0.2% 3.8% 3.8% 3.8% 3.8% 37.9% 37.9% 37.9% 37.9% 46.2% 46.2% 46.2% 46.2% 17.0% 43.0% 35.0% 5.0% 17.0% 43.0% 35.0% 5.0% 17.0% 43.0% 35.0% 5.0% 17.0% 43.0% 35.0% 5.0% 12

Data Management Highlights Steady State Data Oil Circulation rate Refrigerant side Qevp Power consumption COP Item Cooling Capacity Match Average speed ratio Clutch cycling data Using average speed ratio. Average of required speed ratios to meet cooling capacity at I35a, L35a and M35a Average over a 10 minute period Integration of data (of full on-off cycles only) over a 10 minute period. Real Time Measurement Corrected with real-time oil circulation data (steady state only) Description Fixed compressor: Clutch cycled to match capacity Corrected for belt power consumption Using Qevp calculated from air side 13

Data Management: Equipment Validation Refrigerant & air side energy balance is within +/- 5%. 8 7 Steady State Test Points +/- 5% Qevp Ref Side (kw) 6 5 4 3 2 1 1 2 3 4 5 6 7 8 Qevp Air Side (kw) 14

Refrigerant Charge Determination L35a condition. Final charge amount: center point of the subcooling plateau. Same charge amount used for all compressors. 45 Cond SC Evap SH Pd 200 40 Subcool / Superheat (DegF) 35 30 25 20 15 10 5 Final Charge 180 160 140 120 Discharge Pressure (psig) 0 100 10 12 14 16 18 20 22 24 26 28 30 32 R134a Amount (OZ) 15

TXV Confirmation / Selection Two TXV s were compared, both from production systems: - TXV #1: System charge, 1.5 ton - TXV #2: Cross Charge, 1.0 ton TXV #2 was selected because: - It didn t hunt with variable compressors at low load conditions. - Its superheat at higher loads was also in normal ranges. Evaporator Superheat (degf) 25 20 15 10 5 TXV 1 TXV 2 TXV #1 hunting @ I15 and L15 conditions. 0 I45 L45 M45 H45 I35a L35a M35a H35a I25a L25a M25a H25a I15 L15 M15 H15 16

Compressor Technology / Type and its Impact on GWP Contents Chapter 1: Introduction Chapter 2: Test Description Chapter 3: Results & Conclusions TRSE07 & TRSA09 vs. A FD17 TRSE07 & TRSA09 vs. D IVD14 Conclusions Chapter 4: Further Analysis Beyond IMAC Chapter 5: Appendix 17

Results - TRSE07 & TRSA09 vs. A FD17 7 TR Cycling A FD17 6 5 TR Cycling TRSE07 TRSA09 Qevp (kw) 4 3 2 All Compressors Cycling 1 0 I45 L45 M45 H45 I35a L35a M35a H35a I25a L25a M25a H25a I15 L15 M15 H15 Test Conditions Matched Cooling Capacity 18

Results - TRSE07 & TRSA09 vs. A FD17 Superheat and Subcooling Comparison Superheat or Subcooling (degf) 30 25 20 15 10 5 SH - A FD17 SH - TRSE07 SH - TRSA09 SC- A FD17 SC - TRSE07 SC - TRSA09 SH & SC at cycling conditions not shown 0 I45 L45 M45 H45 I35a L35a M35a H35a I25a Test Conditions Superheat and sub cooling are similar, indicating same system characteristics for all compressors 19

Results - TRSE07 & TRSA09 vs. A FD17 COP Comparison 9 8 A FD17 TRSE07 TRSA09 7 6 COP 5 4 3 2 1 0 I45 L45 M45 H45 I35a L35a M35a H35a I25a L25a M25a H25a I15 L15 M15 H15 Test Conditions Over all TRSA09, TRSE07 COP are higher than A FD17 particularly at low / mild load conditions. 20

Results - TRSE07 & TRSA09 vs. A FD17 Annualized Energy Consumption Annual Energy Consumption (MJ) 800 700 600 500 400 300 200 Ref. Lower Energy = Lower GWP 28% less 19% less A FD17 TRSE07 TRSA09 TR compressors energy consumption is significantly less (lower GWP) than A FD17 21

Results - TRSE07 & TRSA09 vs. D IVD 14 7 6 TR Cycling TR Cycling D IVD14 TRSE07 TRSA09 5 Qevp (kw) 4 3 2 TR Cycling 1 0 I45 L45 M45 H45 I35a L35a M35a H35a I25a L25a M25a H25a I15 L15 M15 H15 Test Conditions Matched Cooling Capacity 22

Results - TRSE07 & TRSA09 vs. D IVD 14 Superheat and Subcooling Comparison Superheat or Subcooling (degf) 30 25 20 15 10 5 SH - D IVD14 SH - TRSE07 SH - TRSA09 SC - D IVD14 SC - TRSE07 SC - TRSA09 SH & SC for TRSE07 / TRSA09 at cycling conditions not shown 0 I45 L45 M45 H45 I35a L35a M35a H35a I25a L25a M25a H25a I15 L15 M15 H15 Test Conditions Superheat and sub cooling are similar, indicating same system characteristics for all compressors 23

Results - TRSE07 & TRSA09 vs. D IVD 14 9 COP Comparison 8 7 D IVD14 TRSE07 TRSA09 6 COP 5 4 3 2 1 0 I45 L45 M45 H45 I35a L35a M35a H35a I25a L25a M25a H25a I15 L15 M15 H15 Test Conditions TRSE07/TRSA09 COP significantly higher at low load conditions, however lower at high speed conditions (H45, H35a & H25a) partly because of engagement torque peaks during cycling 24

Results - TRSE07 & TRSA09 vs. D IVD 14 Annualized Energy Consumption Energy Consumption (MJ) 500 450 400 350 300 250 Ref. Lower Energy = Lower GWP 10.5% less 1.5% less 200 D IVD14 TRSE07 TRSA09 TR compressors energy consumption is significantly less (lower GWP) than D IVD14 25

Conclusions TR compressors annual energy consumption is the least among tested compressors: TRSE07 annual power consumption is: - 28% less than A FD17-10.5% less than D IVD14. Similarly, TRSA09 annual power consumption is: - 19% less than A FD17-1.5% less than D IVD14 Lower Energy Consumption = Lower GWP 26

Compressor Technology / Type and its Impact on GWP Contents Chapter 1: Introduction Chapter 2: Test Description Chapter 3: Results & Conclusions Chapter 4: Further Analysis Beyond IMAC Chapter 5: Appendix 27

Further Analysis Beyond IMAC Study Compressor clutch coil power consumption Annualized power consumption in Watts 28

Further Analysis Beyond IMAC Study TRSE07 & TRSA09 vs. A FD17 Annualized Power Consumption in Watts (w/ & w/o clutch coil power consumption) Power Consumption (W) 800 700 600 500 400 300 658 670 Lower Power = Lower GWP 474 487 Excluding Coil Power Including Coil Power 532 544 200 A FD17 TRSE07 TRSA09 Coil power consumption has little impact on the overall power consumption rate. TR compressors power consumption is significantly lower than A FD17 29

Further Analysis Beyond IMAC Study TRSE07 & TRSA09 vs. D IVD14 Annualized Power Consumption in Watts (w/ & w/o clutch coil power consumption) 500 Excluding Coil Power Power Consumption (W) 400 300 Including Coil Power Lower Power = Lower GWP 392 381 358 346 387 416 200 TRSE07 TRSA09 D IVD14 Coil power consumption has little impact on the overall power consumption rate. TR compressors power consumption is significantly lower than D IVD14 30

Further Analysis Beyond IMAC Study Conclusions TRSE compressor annual power consumption is significantly less than all tested compressor technologies. Including clutch coil power, TRSE07 power consumption is: - 183 Watts less than A Fixed Swash Plate - 58 Watts less than D Internally Variable Swash Plate Lower Watts means: - Reduced fuel consumption (higher vehicle MPG) - Lower GWP. 31

Compressor Technology / Type and its Impact on GWP Contents Chapter 1: Introduction Chapter 2: Test Description Chapter 3: Results & Conclusions Chapter 4: Further Analysis Beyond IMAC Chapter 5: Appendix 32

Appendix I. Evaporator Cooling Capacity Calculations: Qevp: Air side calculations Q evp m a ( hai hao) m wcpw( Tai Tao) The 2nd term on the RHS represents sensible energy of condensed moisture. Enthalpy of air using inlet temperatures T 1 and outlet temperature T out1, T out2, and dew points from H u1 and H u2 (see below). During clutch cycling, T out1, T out2 & H u2 (recorded at high sampling rate) are integrated over 10 min. of data (minus partial cycles at start / end). T grid T1, Hu1 (6 TCs) T out1 (Avg of 3 TCs) Air Flow (combo) Air Flow T out2, H u2 HVAC Blower (combo) Evaporator 33

Appendix I. Evaporator Cooling Capacity Calculations: Qevp: Refrigerant side calculations Q evp m r ( hreo hrei ) m oilc p, oil ( Treo Trxi ) The 2nd term on the RHS represents sensible energy change of oil. R134a and oil flow rates are derived from the measured mass flow rate and OCR. 34

Appendix II. COP & Energy Consumption Calculation: Compressor power consumption W c = 2p*(shaft torque)*(shaft speed). Data are averaged / integrated over 10mins. (For cycling data, partial cycles at start / end are removed). Because the torque meter is pulley mounted, the measured torque is also corrected for transmission losses. COP = Qevp / W c Only Qevp calculated from air side is used for COP calculation because refrigerant side calculation is less reliable at low load conditions. 35

Appendix II. COP & Energy Consumption Calculation: IMAC annualized energy consumption = i 16 ( wtclim ate i 1 ) i ( wt RPM ) i ( AverageQevp) ( COP) i i (Average Qevp) i = average Qevap of all compressors at ith test condition wt climate, wt RPM = IMAC climate and speed weighting factors 36