Repair, Retrofit, or Replace Choices for Servicing R-22 Equipment

Size: px
Start display at page:

Download "Repair, Retrofit, or Replace Choices for Servicing R-22 Equipment"

Transcription

1 Repair, Retrofit, or Replace Choices for Servicing R-22 Equipment Brett Van Horn Market Manager HVAC Arkema Inc. 900 First Ave King of Prussia, PA 19406

2 Topics Covered Today R-22 Phase-out EPA Allowances in the Final Rule What it means for you What are your options Repair, Retrofit, or Replace Considerations for servicing with R-22 When to consider replacing equipment When to retrofit and what to consider How to select the right retrofit The benefits of Forane 427A What to keep in mind when performing a retrofit

3 R-22 Phase-Out (Production/Imports)

4 Market Response to R-22 Phase-Out Supply / Demand Production and Importation ends 2020 R-22 will be available after 2020 Supply versus Demand will drive price R-22 Retrofit Activity Refrigeration Supermarkets have been slowly retrofitting over the last 7 years Air Conditioning Retrofits activity increased recently Forane 427A The Easy Retrofit TM New Refrigerants for New Systems Forane 410A Air Conditioning Forane 407A Refrigeration Forane 404A Refrigeration

5 What s your Plan? REPAIR Continue servicing equipment with R-22 RETROFIT Replace R-22 with a Retrofit Refrigerant in the existing equipment REPLACE Replace the old equipment with a new system using a new refrigerant

6 Option 1: Repair with R-22 When to consider servicing R-22 equipment with R-22 The system is under warranty Follow the equipment manufacturers servicing recommendations The system is working well and leak free If it s not broke don t fix it! R-22 will work the best in R-22 equipment The system is undersized Most R-22 retrofits have lower capacity than R-22 The system uses a flooded evaporator All retrofit refrigerants are blends with noticeable glide Fractionation in the evaporator may degrade operation Immiscible lubricants may collect the evaporator

7 Option 2: Replace Equipment When to consider replacing the equipment The system is no longer under warranty Time to also consider Retrofits or Replacing equipment The system is not working well or needs major repairs R-22 equipment will generally not work better with a retrofit than with R-22 Weigh the cost of repairs and operating old equipment versus costs of installing new, efficient equipment Efficiency driven end users Many new systems offer significantly higher SEER Replace older, less efficient systems with newer, more efficient systems to reduce energy consumption

8 R-22 Replacement Refrigerants New Systems Air Conditioning Other replacements include R-134a, R-407C Refrigeration

9 Option 3: Retrofit When to consider using a retrofit refrigerant The system is no longer under warranty The system has persistent leaks Switch to a retrofit refrigerant to avoid repeated charging with R-22 The system is correctly sized or oversized Systems may become critically undersized if choosing a poor retrofit Some oversized systems will benefit from using Forane 427A Doing other system repairs Changing compressor, coils, etc. use the time to perform a retrofit Line sets are buried or difficult to replace Line sets must be replaced if replacing equipment to new refrigerant

10 Option 3: Retrofit When NOT to consider using a retrofit refrigerant The system is under warranty The system undersized The system uses a flooded evaporator

11 Overview of Retrofits Refrigerants

12 R-22 Retrofit Blends The increasing list of R-22 Retrofits. R-427A R-404A R-421A R-422B R-422E R-424A R-507A R-407A R-417A R-421B R-422C R-428A R-407F Etc. R-407C R-417B R-422A R-422D R-434A R-438A Which Retrofit Refrigerant to Use?

13 There are ALWAYS Tradeoffs with Retrofits None work as well as R-22 OVERALL No retrofit will match the capacity and efficiency across all conditions None are miscible with MO or AB HFC refrigerants are immiscible with mineral oil/alkyl benzene Some systems will require either a partial or total oil change to POE None will work in every R-22 system Systems with flooded evaporators may have issues using refrigerant blends Bottom line: There are no Drop-Ins Take the time to do it right

14 HFC Component Comparison R-22 Retrofits are blends containing two or more HFC components R-32 R-125 R-143a R-134a Cond. Pressures (%) V. R. Capacity (%) COP (%) Mass Flow Rate (%) Discharge Temps ( F) GWP (100 year) Flammability A2L A1 A2L A1 MO / AB Solubility Very Poor Very Poor Poor Very Poor Relative to R-22, Standard 105 F Condenser, 25 F Evaporator, 10 F of Superheat & Subcooling GWP from the IPCC AR5

15 Blend Issues Temperature Glide Single Component Temperature Superheated Boiling/Condensing Subcooled Evaporating Condensing

16 Blend Issues Temperature Glide Single Component Temperature Superheated Boiling/Condensing Subcooled Evaporating Zeotropic Blend Condensing Temperature Boiling/Condensing Glide Position in heat exchanger

17 Example Blend Compositions (weight %) R-32 R-125 R-143a R-134a R-290 R-600a R-600 R-601a Lubricant R-404A R-407A R-407C R-407F R-417A R-417B R-421A Added R-421B Added R-422A R-422B R-422C R-422D R-424A R-427A R-428A R-434A R-438A R-507A

18 Compositions of Some Retrofit Options (wt%) R-125 R-134a R-143a R-32 Hydrocarbons R-600 R-600a R-601a Forane 427A Forane 407A Forane 407C R-422D R-438A

19 GWP Comparison of R-22 Replacements Global Warming Potential GWP from IPCC AR4 1,700 R-22 GWP = 1,810 2,300 Global Warming Potential (100 Yr.) 2,730 4,000 R-427A R-407C R-407A R-407F R-438A R-417A R-421A R-424A R-422B R-404A R-507 R-422D R-422A R-422C R-428A R-434A R-421B R-417B R-407B

20 Refrigerant Classifications Lower Toxicity OEL 500 ASHRAE Standard 34 Classifies refrigerants based on flammability and toxicity Determines how refrigerants are treated in codes and standards Non-Flammable Mildly Flammable Flammable Highly Flammable No flame LFL > 0.1 kg/m 3 and HOC < 19 MJ/kg LFL 0.1 kg/m 3 propagation BV 10 cm/s BV > 10 cm/s HOC 19 MJ/kg A1 A2L A2 A3 R-11 R-12 R-22 R-134a R-410A R-404A R-427A R-407A R-407C R-4507A R-408A others R-32 R-143a R-152a R-290: Propane R-600: Butane R-600a: Isobutane Higher Toxicity OEL < 500 B1 B2L B2 B3 R-123 NH3

21 R-22 Retrofit Metrics* Capacity (%) COP (%) Mass Flow (%) Discharge P (psi) Suction P (psi) Discharge T ( F) R-407F +5 R-507A +5 R-428A R-404A R-407A 0 0 R-407C -5 R-421B R-422A -5 R-434A R-422C R-417B R-427A R-438A R-422D R-421A R-422B R-424A R-417A R-407C -3 R-427A -3 R-407A R-417A R-438A R-421A R-424A R-422B R-407F R-507A R-422D R-404A R-417B -9 R-434A -9 R-422C R-422A R-421B R-428A R-428A R-421B R-422A R-422C R-417B +45 R-434A R-422D R-507A R-404A R-422A R-404A R-407F R-422B R-421A R-421B R-422C R-424A R-417A R-417B R-407A R-434A R-438A R-407C R-427A R-407A R-407C 0 0 R-407F R-428A R-507A R-422D R-427A 0 R-438A 0 R-422B -15 R-421A -15 R-424A R-417A R-428A R-507A R-404A R-422A R-421B R-422C R-434A R-407F R-417B R-407A 0 0 R-407C R-422D R-427A -5 R-438A -5 R-422B R-421A R-424A R-417A R-407F R-407C -15 R-407A R-427A R-438A R-417AR-404AR-424A R-421A R-507A R-421B R-434A R-422B R-422D R-428A -45 R-417B -45 R-422A R-422C Capacity (%) COP (%) Mass Flow (%) Discharge P (psi) Suction P (psi) Discharge T ( F) *Standard Cycle 105 F Condenser, 25 F Evaporator, 10 F Subcooling & 10 F Superheat

22 R-22 Retrofit Metrics* Capacity (%) COP (%) Mass Flow (%) Discharge P (psi) Suction P (psi) Discharge T ( F) R-407A R-407A 0 0 R-407C -5-5 R-427A R-407C -3 R-427A -3 R-407A R-427A R-407A R-407C R-407C R-427A R-407A 0 0 R-407C R-427A R-407C -15 R-407A R-427A Capacity (%) COP (%) Mass Flow (%) Discharge P (psi) Suction P (psi) Discharge T ( F) *Standard Cycle 105 F Condenser, 25 F Evaporator, 10 F Subcooling & 10 F Superheat

23 R-22 Retrofit Recommendations Forane 407C Forane 407A Forane 427A Applications Air Conditioning MT & LT Refrigeration Air Conditioning MT & LT Refrigeration Advantages Close match in AC Close match in Refrigeration Close match across range of conditions TXV Change NO NO NO Lubricant POE POE POE / (MO / AB)* * Oil change not needed for many installations

24 The Easy Retrofit TM - Forane 427A

25 Oil Management Issues HFC refrigerants are not miscible in mineral oil or alkylbenzene Hydrocarbons sometimes use to improve oil return, but are highly flammable Use of certain HFC components can improve oil return, such as with R-427A Oil can log in the evaporator and degrade performance Decreased capacity and efficiency Loss in capacity may result in undersized equipment after retrofit System layout is important for proper oil management: Compressor on roof feeding evaporators below Systems with long risers or pipe runs Systems with receivers Options in cases of oil return issues: Adding POE oil to the mineral oil/ab or doing a complete oil change If oil is accessible then an oil change is a proper procedure for a good retrofit If oil is not accessible then stay with R-22 or upgrade to a new system

26 A Few Recommendations with R-427A Change the Oil Long line sets Compressor above coil(s) Systems with vertical risers Systems that you are servicing under contract No Oil Change Short, horizontal line sets Packaged or close-coupled systems Systems not under warranty Favorable evaporator layout and position Oil Change Challenges Solvency of POE Need for filter changes Labor and Expenses Oil change is time consuming Flushes Multiple flushes often not required System setup The oil is not always easily accessible General criteria only. A lubricant change may not be required but POE is always recommended for optimal performance

27 Effect of Lubricant on Performance Tests conducted with Forane 427A, R-438A, R-422D Forane 427A provided best performance across range of conditions Using POE increases COP and Capacity COP (relative to max) R-427A / MO R-427A / POE R-422D / MO R-422D / POE R-438A / MO R-438A / POE Capacity (relative to max) F 25 F 50 F 0 F 25 F 50 F Box Temperature ( o F)

28 CASE STUDIES Air-Conditioning Without Oil-Change: Solar Supply Warehouse, Lake Charles, LA Refrigeration With Oil-Change: Sherm s Thunderbird, Roseburg, OR

29 Retrofit to Forane 427A No Oil Change Solar Supply Warehouse Office (Lake Charles, LA) Application: Air Conditioning (3.5-ton heat pump) Mineral Oil: No oil change Filter-drier and Schrader valve caps and cores were replaced Results: No significant differences in system performance observed Operating pressures with Forane 427A closely matched those with R-22 Compressor ran at lower discharge temperatures

30 Retrofit to Forane 427A Oil Change to POE Sherm s Thunderbird (Roseburg, OR) Application: Supermarket Refrigeration (MT & LT) 3 systems: low-temp, frozen food, deli cases & heat reclaim Mineral Oil replaced with POE No replacement of TXVs Results: Reduced operating cost 7% reduction Case temperatures maintained at desired setpoints Low discharge temperatures

31 Summary R-22 Phase-out: Don t Panic Production/Importation of virgin R-22 will cease in 2020 R-22 equipment can still be serviced with existing R-22 after 2020 You have options for your equipment: 1. Continue to service equipment with R Perform a retrofit to the existing equipment 3. Replace the old equipment for new When performing a retrofit, do your homework Be sure the installation is right for a retrofit Choose a retrofit that closely matches R-22 like Forane 427A Choose a retrofit that minimizes the work required like Forane 427A Take the time to do it right

32 Forane PT Calculator App

33 R-22 Retrofit Resources For more information on Arkema s R-22 Retrofit Solutions, please visit our website at Other useful links: Arkema s N.A. Website: Forane Refrigerant Training: Forane PT App Now supports 8 languages! itunes: Androids: earch_result#?t=w251bgwsmswyldesimnvbs5gb3jhbmuurm9yyw5lil0 Technical Service: THANK YOU FOR YOUR TIME!

Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems

Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems Dr. Charles C. Allgood 1, C. Curtis Lawson 2 1 DuPont Fluorochemicals, Wilmington, DE, USA E-mail: [email protected]

More information

SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS 2009 Tecumseh Products Company. All rights reserved. Page 1 of 8 Refrigerant R22 is widely used for residential and commercial air conditioning, as

More information

RS-52 (R428A) RS-52: PHYSICAL PROPERTIES RS-52 R502 Molecular weight 107.5 111.6 Temperature glide o C 0.5 0.2 Boiling point (1 atm)

RS-52 (R428A) RS-52: PHYSICAL PROPERTIES RS-52 R502 Molecular weight 107.5 111.6 Temperature glide o C 0.5 0.2 Boiling point (1 atm) RS-52 (R428A) COMPOSITION % HFC 125 77.5 HFC 143a 20.0 R600a 1.9 R290 0.6 HCFC replacement Temperature glide R22, 502 & interim blends Approximately 0.8 o C Drop-in or long term Both Lubricant MO/AB/POE

More information

RS-24 (R426A): Q & A

RS-24 (R426A): Q & A RS-24 (R426A): Q & A 1 Q: What is RS-24? A: RS-24 is a non ozone depleting Drop-in replacement for R12 in all applications including mobile air conditioning. 2 Q: Yes, but what does RS-24 contain? A: RS-24

More information

Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems

Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 21 Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems

More information

Low GWP Replacements for R404A in Commercial Refrigeration Applications

Low GWP Replacements for R404A in Commercial Refrigeration Applications Low GWP Replacements for R404A in Commercial Refrigeration Applications Samuel YANA MOTTA, Mark SPATZ Honeywell International, 20 Peabody Street, Buffalo, NY 14210, [email protected] Abstract

More information

HCFC-22 Retrofits. There has been increased emphasis on retrofitting R-22

HCFC-22 Retrofits. There has been increased emphasis on retrofitting R-22 HCFC-22 Retrofits A c l o s e l o o k a t t h e r e f r i g e r a n t / l u b r i c a n t i n t e r a c t i o n s. B y S a m u e l F. Y a n a M o t t a, E l i z a b e t D. V e r a B e c e r r a, R o n

More information

RS-44 (R424A) : Q & A

RS-44 (R424A) : Q & A RS-44 (R424A) : Q & A 1 Q: What is RS-44? A: RS-44 is a non ozone depleting Drop-in replacement for R22 in most applications. 2 Q: Yes, but what does RS-44 contain? A: RS-44 is a blend of HFC134a, HFC125,

More information

THE REPLACEMENT OF R-22

THE REPLACEMENT OF R-22 ENGLISH TRANSLATION OF ARTICLE IN FRIO-CALOR AIRE ACONDICIONDAO BY GAS-SERVEI, S.A JUNE 2010 THE REPLACEMENT OF R-22 Courtesy of D. Lluis Giralt Lopez (Chemical Engineering Industrial) Gas Technical Department

More information

Low-GWP Refrigerants for Air Conditioning and Refrigeration Applications. Samuel F Yana Motta

Low-GWP Refrigerants for Air Conditioning and Refrigeration Applications. Samuel F Yana Motta Low-GWP Refrigerants for Air Conditioning and Refrigeration Applications Samuel F Yana Motta Refrigerants for Stationary Applications HONEYWELL CONFIDENTIAL N Series L Series Current Product Reduced GWP

More information

How To Design A Refrigeration System

How To Design A Refrigeration System AIRAH Refrigeration (in HVAC) Back to Basics For the First Time Terms of Reference What this session is NOT about Detailed Refrigeration Design Detailed analysis of various Refrigants properties Comparison

More information

Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems

Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems William M. Corcoran, George Rusch, Mark W. Spatz, and Tim Vink AlliedSignal, Inc. ABSTRACT

More information

REFRIGERANT REFERENCE GUIDE

REFRIGERANT REFERENCE GUIDE REFRIGERANT REFERENCE GUIDE WORLWIDE REFRIGERANT SUPPLIER 2004 FOURTH EDITION 2004 DISCLAIMER This publication is designed to provide accurate and authoritative information. It is not to be construed as

More information

R407C GUIDELINES FOR UTILIZATION OF. DATE: August 2009 REFERENCE DOCUMENT NO. RD-0005-E GUIDELINES FOR UTILIZATION OF R407C

R407C GUIDELINES FOR UTILIZATION OF. DATE: August 2009 REFERENCE DOCUMENT NO. RD-0005-E GUIDELINES FOR UTILIZATION OF R407C GUIDELINES FOR UTILIZATION OF R407C 2009 Tecumseh Products Company. All rights reserved. Page 1 of 6 After many years of testing and investigation, R407C is recognized as a suitable alternative refrigerant

More information

Scroll compressors for Low GWP Heat Pumps using R290 natural refrigerant. Pierre Ginies, Next Heat Pump Generation 2015 p.ginies@danfoss.

Scroll compressors for Low GWP Heat Pumps using R290 natural refrigerant. Pierre Ginies, Next Heat Pump Generation 2015 p.ginies@danfoss. Scroll compressors for Low GWP Heat Pumps using R290 natural refrigerant Pierre Ginies, Next Heat Pump Generation 2015 [email protected] Danfoss Commercial Compressors Leading compressor R&D and manufacturing

More information

Refrigeration Basics 101. By: Eric Nelson

Refrigeration Basics 101. By: Eric Nelson Refrigeration Basics 101 By: Eric Nelson Basics Refrigeration is the removal of heat from a material or space, so that it s temperature is lower than that of it s surroundings. When refrigerant absorbs

More information

Technical Note: Comparing R407C and R410A as Alternatives for R22. A Technical Note from the Experts in Business-Critical Continuity

Technical Note: Comparing R407C and R410A as Alternatives for R22. A Technical Note from the Experts in Business-Critical Continuity Technical Note: Comparing R407C and R410A as Alternatives for R22 A Technical Note from the Experts in Business-Critical Continuity Purpose The purpose of this document is to provide a brief overview of

More information

A Comparison of an R22 and an R410A Air Conditioner Operating at High Ambient Temperatures

A Comparison of an R22 and an R410A Air Conditioner Operating at High Ambient Temperatures R2-1 A Comparison of an R22 and an R410A Air Conditioner Operating at High Ambient Temperatures W. Vance Payne and Piotr A. Domanski National Institute of Standards and Technology Building Environment

More information

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions Refrigerant Changeover Guidelines R-22 to R-407C Leading the Industry with Environmentally Responsible Refrigerant Solutions Copeland does not CFC advocate the wholesale changeover of HCFC HCFC refrigerants

More information

Commercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1:

Commercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1: PART 1: CO 2 Commercial refrigeration has been in the environmental spotlight for more than a decade, especially as leakage studies have revealed the true effects of hydrofluorocarbon (HFC) emissions.

More information

TEST REPORT #44. System Drop-in Tests of Refrigerant R-32 in Single Packaged Vertical Heat Pump (SPVH)

TEST REPORT #44. System Drop-in Tests of Refrigerant R-32 in Single Packaged Vertical Heat Pump (SPVH) Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP) TEST REPORT #44 System Drop-in Tests of Refrigerant R-32 in Single Packaged

More information

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014 ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014 Explanation of the refrigeration cycle. Compressors. Benefits and operating characteristics. -Reciprocating

More information

REFRIGERANT 410A. Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois 60016. Information compiled by Frank Prah, CMS

REFRIGERANT 410A. Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois 60016. Information compiled by Frank Prah, CMS Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois 60016 REFRIGERANT 410A Information compiled by Frank Prah, CMS INTRODUCTION Recently a new refrigerant, R-410A, has been formulated

More information

P08 Köldmedier med låg växthuseffekter

P08 Köldmedier med låg växthuseffekter P08 Köldmedier med låg växthuseffekter Pavel Makhnatch Tranås, 17-18 May Reference: IPCC, 2013 3 4 5 Growth of climate change commitments from HFC banks and emissions Reference: Velders et al. 2014 6

More information

Refrigerants for Residential and Commercial Air Conditioning Applications

Refrigerants for Residential and Commercial Air Conditioning Applications Refrigerants for Residential and Commercial Air Conditioning Applications October 2008 Table of contents Executive summary 2 Introduction and background 3 Environmental drivers 4 Regulatory update 8 Criteria

More information

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions Refrigerant Changeover Guidelines R-22 to R-407C Leading the Industry with Environmentally Responsible Refrigerant Solutions Emerson Climate CFC Technologies, Inc. does not advocate the HCFC wholesale

More information

EU f-gas regulation EN 517/2014.

EU f-gas regulation EN 517/2014. F-gas regulation EU f-gas regulation EN 517/2014. Helping you meet your environmental obligations. 02 EU f-gas regulation EU f-gas regulation. Reducing your environmental impact. The updated f-gas regulation

More information

Troubleshooting HVAC/R systems using refrigerant superheat and subcooling

Troubleshooting HVAC/R systems using refrigerant superheat and subcooling Troubleshooting HVAC/R systems using refrigerant superheat and subcooling Application Note Troubleshooting and servicing refrigeration and air conditioning systems can be a challenging process for both

More information

TEST REPORT #31. System Drop-in Test of Refrigerant R-32 in Split Air-conditioning System

TEST REPORT #31. System Drop-in Test of Refrigerant R-32 in Split Air-conditioning System Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP) TEST REPORT #31 System Drop-in Test of Refrigerant R-32 in Split Air-conditioning

More information

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM WITH R404A, R407C AND R410A

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM WITH R404A, R407C AND R410A Int. J. Mech. Eng. & Rob. Res. 213 Jyoti Soni and R C Gupta, 213 Research Paper ISSN 2278 149 www.ijmerr.com Vol. 2, No. 1, January 213 213 IJMERR. All Rights Reserved PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION

More information

Refrigerant identification and equipment issues in relation to HCFC phase-out. Ole Reinholdt Nielsen

Refrigerant identification and equipment issues in relation to HCFC phase-out. Ole Reinholdt Nielsen Refrigerant identification and equipment issues in relation to HCFC phase-out Ole Reinholdt Nielsen Belize, March 3, 2010 Outline Brief introduction; Refrigerant identification: Historically; Options for

More information

Engineers Newsletter. HVAC Refrigerants: A Balanced Approach. providing insights for today s hvac system designer. volume 40 2. Refrigerant History

Engineers Newsletter. HVAC Refrigerants: A Balanced Approach. providing insights for today s hvac system designer. volume 40 2. Refrigerant History providing insights for today s hvac system designer Engineers Newsletter volume 40 2 HVAC Refrigerants: A Balanced Approach One of the constant themes throughout the history of the HVAC industry is the

More information

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents. The System Evaluation Manual and Chiller Evaluation Manual have been revised and combined into this new book; the Air Conditioning and Refrigeration System Evaluation Guide. It will be available soon as

More information

Refrigerant Changeover Guidelines HCFC R-22 to HFC R-404A/R-507. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Refrigerant Changeover Guidelines HCFC R-22 to HFC R-404A/R-507. Leading the Industry with Environmentally Responsible Refrigerant Solutions Refrigerant Changeover Guidelines HCFC R-22 to HFC R-404A/R-507 Leading the Industry with Environmentally Responsible Refrigerant Solutions Copeland does not advocate the wholesale changeover of HCFCs

More information

HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation. Richard Lord Carrier Fellow

HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation. Richard Lord Carrier Fellow HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation Richard Lord Carrier Fellow HVAC Industry Challenges and Issues Ozone Deletion Global Warming

More information

Ground-breaking conversion of critical Data Room WaterChiller from R22 to R422D / MO29

Ground-breaking conversion of critical Data Room WaterChiller from R22 to R422D / MO29 Ground-breaking conversion of critical Data Room WaterChiller from R22 to R422D / MO29 A refrigerant retrofit project, involving the conversion of a large Data Room cooling system from R22 to R422D (DuPont

More information

Refrigerant Changeover Guidelines R-502 to R-402A/R-408A. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Refrigerant Changeover Guidelines R-502 to R-402A/R-408A. Leading the Industry with Environmentally Responsible Refrigerant Solutions Refrigerant Changeover Guidelines R-502 to R-402A/R-408A Leading the Industry with Environmentally Responsible Refrigerant Solutions Copeland does not advocate the wholesale CFC changeover of CFC HCFC

More information

Planning for the ban on R22 in building air conditioning

Planning for the ban on R22 in building air conditioning - ACHPI 32 Planning for the ban on R22 in building air conditioning Those responsible for cooling and heating commercial properties are under increased pressure to improve energy efficiency and negotiate

More information

Part A: Fluid properties

Part A: Fluid properties UNEP Ozone Secretariat UNEP Ozone Secretariat Background Workshop Material on HFC for management: HFC Workshop, technical 2015 issues Bangkok, 20 and 21 April 2015 FACT SHEET 15 Glossary of terms and technical

More information

Any Service Technician Can Fix It A Good Service Technician Can Figure Out What s Wrong With It.

Any Service Technician Can Fix It A Good Service Technician Can Figure Out What s Wrong With It. I Dave s Statement If the thermostat calls for cooling, and the furnace fan is running properly, and the coil airflow is adequate, and the condenser fan is running properly, and the condenser airflow is

More information

System Diagnosis. Proper vehicle diagnosis requires a plan before you start

System Diagnosis. Proper vehicle diagnosis requires a plan before you start System Diagnosis Proper vehicle diagnosis requires a plan before you start Following a set procedure to base your troubleshooting on will help you find the root cause of a problem and prevent unnecessary

More information

Guide to good leak testing

Guide to good leak testing Page 0 Guide to good leak testing The Institute of Refrigeration, working with the Carbon Trust, brings you REAL Zero Refrigerant Emission and Loss Zero. The aim of this project is in the title zero refrigerant

More information

Commercial CO2 Refrigeration Systems. Guide for Subcritical and Transcritical CO2 Applications

Commercial CO2 Refrigeration Systems. Guide for Subcritical and Transcritical CO2 Applications Commercial CO2 Refrigeration Systems Guide for Subcritical and Transcritical CO2 Applications 2 Contents Chapter 1. Introduction 4 Chapter 2. CO 2 Basics and Considerations as a Refrigerant 5 Section 1.

More information

Mohan Chandrasekharan #1

Mohan Chandrasekharan #1 International Journal of Students Research in Technology & Management Exergy Analysis of Vapor Compression Refrigeration System Using R12 and R134a as Refrigerants Mohan Chandrasekharan #1 # Department

More information

ADVANCES IN SUPERMARKET REFRIGERATION SYSTEMS

ADVANCES IN SUPERMARKET REFRIGERATION SYSTEMS ADVANCES IN SUPERMARKET REFRIGERATION SYSTEMS Van D. Baxter, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6070 ABSTRACT Present supermarket refrigeration systems require very large refrigerant charges

More information

Characteristics of Evaporators

Characteristics of Evaporators Characteristics of Evaporators Roger D. Holder, CM, MSME 10-28-2003 Heat or Energy In this paper, we will discuss the characteristics of an evaporator coil. The variance of the operational condenses of

More information

Increasing the evaporation temperature with the help of an internal heat exchanger

Increasing the evaporation temperature with the help of an internal heat exchanger Increasing the evaporation temperature with the help of an internal heat exchanger A. TAMBOVTSEV (a), H. QUACK (b) (a,b) Technische Universität Dresden, D-01062, Dresden, Germany (a) Fax: (+49351) 463-37247,

More information

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES After studying this unit, the reader should be able to explain the purpose of the condenser in a refrigeration system. describe differences

More information

Todd M. Rossi, Ph.D. President

Todd M. Rossi, Ph.D. President Residential Air Conditioning Fault Detection and Diagnostics (FDD) and Protocols to Support Efficient Operation DOE - Building America Program Residential Buildings Integration Meeting - July 20-22, 2010

More information

Information on New Refrigerant (R-1234yf) for A/C Service

Information on New Refrigerant (R-1234yf) for A/C Service Information on New Refrigerant (R-1234yf) for A/C Service 2013 Cadillac ATS, XTS This bulletin is being revised to include procurement and labeling information for recovery cylinders to be used with GE-50957-Contaminated

More information

Purpose of Refrigeration

Purpose of Refrigeration Refrigeration Outline Purpose of refrigeration Examples and applications Choice of coolant and refrigerants Phase diagram of water and CO 2 Vapor compression refrigeration system Pressure enthalpy diagram

More information

Lesson. 11 Vapour Compression Refrigeration Systems: Performance Aspects And Cycle Modifications. Version 1 ME, IIT Kharagpur 1

Lesson. 11 Vapour Compression Refrigeration Systems: Performance Aspects And Cycle Modifications. Version 1 ME, IIT Kharagpur 1 Lesson Vapour Compression Refrigeration Systems: Performance Aspects And Cycle Modifications Version ME, IIT Kharagpur The objectives of this lecture are to discuss. Performance aspects of SSS cycle and

More information

TECHNICAL ANNEX. Alternatives to HCFCs/HFCs in unitary air conditioning equipment at high ambient temperatures. November 2014

TECHNICAL ANNEX. Alternatives to HCFCs/HFCs in unitary air conditioning equipment at high ambient temperatures. November 2014 TECHNICAL ANNEX Alternatives to HCFCs/HFCs in unitary air conditioning equipment at high ambient temperatures November 2014 Authors: Bastian Zeiger, Barbara Gschrey, Winfried Schwarz Öko-Recherche, Frankfurt/Main,

More information

Energy Procedia Energy 00 Procedia (2011) 000 000 14 (2012) 56 65

Energy Procedia Energy 00 Procedia (2011) 000 000 14 (2012) 56 65 Available online at www.sciencedirect.com Available online at www.sciencedirect.com Energy Procedia Energy 00 Procedia (2011) 000 000 14 (2012) 56 65 Energy Procedia www.elsevier.com/locate/procedia ICAEE

More information

Heat Recovery In Retail Refrigeration

Heat Recovery In Retail Refrigeration This article was published in ASHRAE Journal, February 2010. Copyright 2010 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. Posted at www.ashrae.org. This article may not

More information

International Refrigerant Standards and their Influence on the Global HVAC Industry and Refrigerant Replacement

International Refrigerant Standards and their Influence on the Global HVAC Industry and Refrigerant Replacement International Refrigerant Standards and their Influence on the Global HVAC Industry and Refrigerant Replacement Tom Watson, P.E. Fellow ASHRAE, Life Member President ASHRAE Issues Choosing a refrigerant

More information

How Ground/Water Source Heat Pumps Work

How Ground/Water Source Heat Pumps Work How Ground/Water Source s Work Steve Kavanaugh, Professor Emeritus of Mechanical Engineering, University of Alabama Ground Source s (a.k.a. Geothermal s) are becoming more common as the costs of energy

More information

Air Conditioning 101. STN Presentation AC101

Air Conditioning 101. STN Presentation AC101 Air Conditioning 101 What is Refrigeration? Refrigeration is Cooling by the Removal of Heat Heat is Measured In BTU s A BTU is a British Thermal Unit It is the Amount of Heat to Raise One Pound of Water,

More information

Skills Canada National Competition Instructions and Competition Details 38 Refrigeration and Air Conditioning / Post - Secondary May 27-30, 2015 -

Skills Canada National Competition Instructions and Competition Details 38 Refrigeration and Air Conditioning / Post - Secondary May 27-30, 2015 - Skills Canada National Competition Instructions and Competition Details / Post - Secondary May 27-30, 2015 - Saskatoon 1. Test Project Details This project is designed to test the range of skills used

More information

High School Graduation years 2013, 2014, 2015. Unit/Standard Number

High School Graduation years 2013, 2014, 2015. Unit/Standard Number 1 Secondary Task List 100 INTRODUCTION TO HVAC 101 Identify HVAC systems. 102 Describe career opportunities in the HVAC profession. 103 Demonstrate awareness of the occupational requirements. 104 Explain

More information

2016 HVAC Test and Repair Application Specifications

2016 HVAC Test and Repair Application Specifications 2016 HVAC Test and Repair Application Specifications HVAC Testing and Repair Measure: Performed on (2 ton and up) existing (DX) packaged or split systems - retrofit There are three separate incentive categories

More information

Commercial CO 2 Refrigeration Systems

Commercial CO 2 Refrigeration Systems Commercial CO 2 Refrigeration Systems Guide for Subcritical and Transcritical CO 2 Applications 2 Contents Chapter 1. Introduction 4 Chapter 2. CO 2 Basics and Considerations as a Refrigerant 5 Section

More information

123 street Salt Lake City, Utah 84092

123 street Salt Lake City, Utah 84092 Salt Lake City, Utah 84092 Prepared for: Sample AC inspection Prepared by: Page 1 of 8 Table of Contents Definitions 2 General Information 2 Air Conditioning 3 Heating System 6 Summary 8 Page 2 of 8 Definitions

More information

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet Perkins Statewide Articulation Agreement Documentation item: Secondary Task List Coversheet The Secondary School agrees to: A. Implement the approved PDE Program(s) of Study. B. Provide assessment of student

More information

Certified HVAC Audit Report Key Takeaways and Implications. Created for: Pets On the Go 445 Logging Road, Building 3 Yardley, PA-19034

Certified HVAC Audit Report Key Takeaways and Implications. Created for: Pets On the Go 445 Logging Road, Building 3 Yardley, PA-19034 Certified HVAC Audit Report Key Takeaways and Implications Created for: Pets On the Go 44 Logging Road, Building 3 Yardley, PA-9034 May, 0 Executive Summary Proposal Generator Demo aims to reduce your

More information

Chapter 2 P-H Diagram Refrigeration Cycle Analysis & Refrigerant Flow Diagram

Chapter 2 P-H Diagram Refrigeration Cycle Analysis & Refrigerant Flow Diagram Chapter 2 P-H Diagram Refrigeration Cycle Analysis & Refrigerant Flow Diagram Copy Right By: Thomas T.S. Wan 温 到 祥 著 Sept. 3, 2008 All rights reserved Industrial refrigeration system design starts from

More information

Impacts of Refrigerant Charge on Air Conditioner and Heat Pump Performance

Impacts of Refrigerant Charge on Air Conditioner and Heat Pump Performance Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2010 Impacts of Refrigerant Charge on Air Conditioner and Heat Pump Performance

More information

Topics: Refrigerant Proliferation, Global Drivers/Regulation

Topics: Refrigerant Proliferation, Global Drivers/Regulation Recent Developments In Refrigerants For Air-Conditioning And Refrigeration Systems Rajan Rajendran Topics: Refrigerant Proliferation, Global Drivers/Regulation Life Cycle Climate Performance Approach Available

More information

Evaporator Coil Installation Instructions

Evaporator Coil Installation Instructions Part # 96654008 July 2010 Evaporator Coil Installation Instructions A-Coil Page 4 Multi-position A-Coil Page 4-7 Slab Coil Page 5 Horizontal A-Coil Top Connection Page 5 Horizontal A-Coil Side Connection

More information

Certification in the safe and efficient use of alternative refrigerants

Certification in the safe and efficient use of alternative refrigerants Certification in the safe and efficient use of alternative refrigerants Dubai, 29th Oct 2014 Marco Buoni VicePresident, AREA Air Conditioning & Refrigeration European contractors Association (www.area-eur.be)

More information

Why and How we Use Capacity Control

Why and How we Use Capacity Control Why and How we Use Capacity Control On refrigeration and air conditioning applications where the load may vary over a wide range, due to lighting, occupancy, product loading, ambient weather variations,

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

THEORETICAL AND EXPERIMENTAL EVALUATION OF AUTOMOBILE AIR-CONDITIONING SYSTEM USING R134A

THEORETICAL AND EXPERIMENTAL EVALUATION OF AUTOMOBILE AIR-CONDITIONING SYSTEM USING R134A THEORETICAL AND EXPERIMENTAL EVALUATION OF AUTOMOBILE AIR-CONDITIONING SYSTEM USING R134A Jignesh K. Vaghela Assistant Professor, Mechanical Engineering Department, SVMIT, Bharuch-392001, (India) ABSTRACT

More information

R-32. The next generation refrigerant for air conditioners and heat pumps. Superior energy efficiency and low GWP

R-32. The next generation refrigerant for air conditioners and heat pumps. Superior energy efficiency and low GWP R-32 The next generation refrigerant for air conditioners and heat pumps Superior energy efficiency and low GWP HFC phase-down and the introduction of R32 The European phase-down of HFCs, which will see

More information

Energy Efficiency in HVAC equipment applications

Energy Efficiency in HVAC equipment applications Energy Efficiency in HVAC equipment applications All Seasons CLIMATE COMFORT Heating Air Conditioning Applied Systems Workshop 6 September 2012 Midrand. Refrigeration PUBLIC All Seasons CLIMATE COMFORT

More information

2004 Standard For Performance Rating Of Positive Displacement Refrigerant Compressors And Compressor Units

2004 Standard For Performance Rating Of Positive Displacement Refrigerant Compressors And Compressor Units 2004 Standard For Performance Rating Of Positive Displacement Refrigerant Compressors And Compressor Units ANSI/AHRI Standard 540 (formerly ARI Standard 540) IMPORTANT SAFETY RECOMMENDATIONS ARI does not

More information

R-32. The next generation refrigerant for air conditioners and heat pumps

R-32. The next generation refrigerant for air conditioners and heat pumps R-32 The next generation refrigerant for air conditioners and heat pumps Daikin is the first company in the world to launch heat pumps and air conditioners charged with R-32. This refrigerant has several

More information

The efficient heat pump

The efficient heat pump The efficient heat pump KCP&L has worked hard to build one of the best reliability records in the industry and we want to help you make the most of the energy we provide. That s why we offer information

More information

Automobile Air Conditioning Primer

Automobile Air Conditioning Primer Automobile Air Conditioning Primer An air conditioner is basically a refrigerator without the insulated box. It uses the evaporation of a refrigerant, like Freon, to provide cooling. The mechanics of the

More information

InvestSmart Business Energy Upgrades Refrigeration Solutions Equipment Catalog 01/01/2015

InvestSmart Business Energy Upgrades Refrigeration Solutions Equipment Catalog 01/01/2015 2015 InvestSmart Business Energy Upgrades 01/01/2015 Table of Contents 1...1-1 1.1 Anti-Sweat Heater Controls... 1-1 1.2 Door Gaskets for Glass and Solid Doors... 1-2 1.3 High-Efficiency Doors for Low

More information

UNIT 2 REFRIGERATION CYCLE

UNIT 2 REFRIGERATION CYCLE UNIT 2 REFRIGERATION CYCLE Refrigeration Cycle Structure 2. Introduction Objectives 2.2 Vapour Compression Cycle 2.2. Simple Vapour Compression Refrigeration Cycle 2.2.2 Theoretical Vapour Compression

More information

Update on a Low GWP Refrigerant: Fluid H

Update on a Low GWP Refrigerant: Fluid H Update on a Low GWP Refrigerant: Fluid H Mark W. Spatz Global Leader Refrigerant Technology Honeywell Fluorine Products SAE 2007 Alternatives Refrigerant Systems Symposium July 17-19, 2007 1 Agenda Material

More information

Refrigeration and air-conditioning. Alfa Laval s offering at a glance

Refrigeration and air-conditioning. Alfa Laval s offering at a glance Refrigeration and air-conditioning Alfa Laval s offering at a glance At Alfa Laval green is cool Alfa Laval products are also installed on oil platforms, in power plants, onboard ships, in the mechanical

More information

MAXIMUM HEAT LOAD TEMPERATURE TESTING ( Differential Temperature Testing )

MAXIMUM HEAT LOAD TEMPERATURE TESTING ( Differential Temperature Testing ) MAXIMUM HEAT LOAD TEMPERATURE TESTING ( Differential Temperature Testing ) The Concept Maximum Heat Load Temperature Testing is a powerful air-conditioning diagnostic and evaluation technique. It is also

More information

D A T A S H E E T. TX6 Thermo Expansion Valves. Alco Controls TX6. Features. Introduction. Construction

D A T A S H E E T. TX6 Thermo Expansion Valves. Alco Controls TX6. Features. Introduction. Construction ALCO s series of Thermo -Expansion Valves are designed for air conditioning, chillers, rooftops, close control, A/C transportation, heat pumps, industrial cooling process and refrigeration applications.

More information

D A T A S H E E T. TX3 Thermo Expansion Valves. Alco Controls TX3. Features. Introduction. Description of bulb charges

D A T A S H E E T. TX3 Thermo Expansion Valves. Alco Controls TX3. Features. Introduction. Description of bulb charges ALCO s TX3 series of Thermo -Expansion Valves are designed for air conditioning, heat pumps and commercial refrigeration applications. The TX3 is ideal for those applications requiring hermetic / compact

More information

A car air-conditioning system based on an absorption refrigeration cycle using energy from exhaust gas of an internal combustion engine

A car air-conditioning system based on an absorption refrigeration cycle using energy from exhaust gas of an internal combustion engine A car air-conditioning system based on an absorption refrigeration cycle using energy from exhaust gas of an internal combustion engine G Vicatos J Gryzagoridis S Wang Department of Mechanical Engineering,

More information

REFRIGERATION (& HEAT PUMPS)

REFRIGERATION (& HEAT PUMPS) REFRIGERATION (& HEAT PUMPS) Refrigeration is the 'artificial' extraction of heat from a substance in order to lower its temperature to below that of its surroundings Primarily, heat is extracted from

More information

Preventive Maintenance Strategies and Technologies Can Pave the Path for Next Generation Rooftop HVAC systems

Preventive Maintenance Strategies and Technologies Can Pave the Path for Next Generation Rooftop HVAC systems Preventive Maintenance Strategies and Technologies Can Pave the Path for Next Generation Rooftop HVAC systems Ramin Faramarzi, P.E. Technology Test Centers October 14, 2014 Overview 1. Why is HVAC maintenance

More information

PG Student (Heat Power Engg.), Mechanical Engineering Department Jabalpur Engineering College, India. Jabalpur Engineering College, India.

PG Student (Heat Power Engg.), Mechanical Engineering Department Jabalpur Engineering College, India. Jabalpur Engineering College, India. International Journal of Emerging Trends in Engineering and Development Issue 3, Vol. (January 23) EFFECT OF SUB COOLING AND SUPERHEATING ON VAPOUR COMPRESSION REFRIGERATION SYSTEMS USING 22 ALTERNATIVE

More information

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating

More information

HFC-free refrigeration technology for the retail business in the Netherlands

HFC-free refrigeration technology for the retail business in the Netherlands HFC-free refrigeration technology for the retail business in the Netherlands (Currently a technical revolution is taking place in the refrigeration industry) BRUNEL University Bart van der Wekken 23rd

More information

Analysis of Alternative Refrigerants to HCFC-22

Analysis of Alternative Refrigerants to HCFC-22 2014 3rd International Conference on Informatics, Environment, Energy and Applications IPCBEE vol.66 (2014) (2014) IACSIT Press, Singapore DOI: 10.7763/IPCBEE. 2014. V66. 34 Analysis of Alternative Refrigerants

More information

THE POSSIBILITY OF USING LIQUIFIED PETROLEUM GAS IN DOMESTIC REFRIGERATION SYSTEMS

THE POSSIBILITY OF USING LIQUIFIED PETROLEUM GAS IN DOMESTIC REFRIGERATION SYSTEMS www.arpapress.com/volumes/vol9issue3/ijrras_9_3_02.pdf THE POSSIBILITY OF USING LIQUIFIED PETROLEUM GAS IN DOMESTIC REFRIGERATION SYSTEMS Zainal Zakaria 1 & Zulaikha Shahrum 2 Department of Gas Engineering,

More information

Chapter 3.4: HVAC & Refrigeration System

Chapter 3.4: HVAC & Refrigeration System Chapter 3.4: HVAC & Refrigeration System Part I: Objective type questions and answers 1. One ton of refrigeration (TR) is equal to. a) Kcal/h b) 3.51 kw c) 120oo BTU/h d) all 2. The driving force for refrigeration

More information

LOBOY 16 AIR CONDITIONERS

LOBOY 16 AIR CONDITIONERS INSTRUCTION MANUAL FOR: LOBOY 16 AIR CONDITIONERS McLean Midwest Corp. dba: McLean Cooling Technology 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleancoolingtech.com

More information

Elements Elements describe the essential outcomes.

Elements Elements describe the essential outcomes. AURETU005 Application Competency Field Unit Sector Elements Elements describe the essential outcomes. Retrofit and modify air conditioning and HVAC systems This unit describes the performance outcomes

More information

Patech. Our Conviction. Quality Service Innovation PATECH FINE CHEMICALS CO., LTD

Patech. Our Conviction. Quality Service Innovation PATECH FINE CHEMICALS CO., LTD Our Conviction Quality Service Innovation Product Categories Refrigeration Lubricants POE for HFC Refrigerants POE for HCFC Refrigerants POE for HFO Refrigerants Special Plasticizers Nontoxic Plasticizer

More information

How does solar air conditioning work?

How does solar air conditioning work? How does solar air conditioning work? In a conventional air conditioning system; The working fluid arrives at the compressor as a cool, low-pressure gas. The compressor is powered by electricity to squeeze

More information