Repair, Retrofit, or Replace Choices for Servicing R-22 Equipment
|
|
|
- Rosamund Cummings
- 10 years ago
- Views:
Transcription
1 Repair, Retrofit, or Replace Choices for Servicing R-22 Equipment Brett Van Horn Market Manager HVAC Arkema Inc. 900 First Ave King of Prussia, PA 19406
2 Topics Covered Today R-22 Phase-out EPA Allowances in the Final Rule What it means for you What are your options Repair, Retrofit, or Replace Considerations for servicing with R-22 When to consider replacing equipment When to retrofit and what to consider How to select the right retrofit The benefits of Forane 427A What to keep in mind when performing a retrofit
3 R-22 Phase-Out (Production/Imports)
4 Market Response to R-22 Phase-Out Supply / Demand Production and Importation ends 2020 R-22 will be available after 2020 Supply versus Demand will drive price R-22 Retrofit Activity Refrigeration Supermarkets have been slowly retrofitting over the last 7 years Air Conditioning Retrofits activity increased recently Forane 427A The Easy Retrofit TM New Refrigerants for New Systems Forane 410A Air Conditioning Forane 407A Refrigeration Forane 404A Refrigeration
5 What s your Plan? REPAIR Continue servicing equipment with R-22 RETROFIT Replace R-22 with a Retrofit Refrigerant in the existing equipment REPLACE Replace the old equipment with a new system using a new refrigerant
6 Option 1: Repair with R-22 When to consider servicing R-22 equipment with R-22 The system is under warranty Follow the equipment manufacturers servicing recommendations The system is working well and leak free If it s not broke don t fix it! R-22 will work the best in R-22 equipment The system is undersized Most R-22 retrofits have lower capacity than R-22 The system uses a flooded evaporator All retrofit refrigerants are blends with noticeable glide Fractionation in the evaporator may degrade operation Immiscible lubricants may collect the evaporator
7 Option 2: Replace Equipment When to consider replacing the equipment The system is no longer under warranty Time to also consider Retrofits or Replacing equipment The system is not working well or needs major repairs R-22 equipment will generally not work better with a retrofit than with R-22 Weigh the cost of repairs and operating old equipment versus costs of installing new, efficient equipment Efficiency driven end users Many new systems offer significantly higher SEER Replace older, less efficient systems with newer, more efficient systems to reduce energy consumption
8 R-22 Replacement Refrigerants New Systems Air Conditioning Other replacements include R-134a, R-407C Refrigeration
9 Option 3: Retrofit When to consider using a retrofit refrigerant The system is no longer under warranty The system has persistent leaks Switch to a retrofit refrigerant to avoid repeated charging with R-22 The system is correctly sized or oversized Systems may become critically undersized if choosing a poor retrofit Some oversized systems will benefit from using Forane 427A Doing other system repairs Changing compressor, coils, etc. use the time to perform a retrofit Line sets are buried or difficult to replace Line sets must be replaced if replacing equipment to new refrigerant
10 Option 3: Retrofit When NOT to consider using a retrofit refrigerant The system is under warranty The system undersized The system uses a flooded evaporator
11 Overview of Retrofits Refrigerants
12 R-22 Retrofit Blends The increasing list of R-22 Retrofits. R-427A R-404A R-421A R-422B R-422E R-424A R-507A R-407A R-417A R-421B R-422C R-428A R-407F Etc. R-407C R-417B R-422A R-422D R-434A R-438A Which Retrofit Refrigerant to Use?
13 There are ALWAYS Tradeoffs with Retrofits None work as well as R-22 OVERALL No retrofit will match the capacity and efficiency across all conditions None are miscible with MO or AB HFC refrigerants are immiscible with mineral oil/alkyl benzene Some systems will require either a partial or total oil change to POE None will work in every R-22 system Systems with flooded evaporators may have issues using refrigerant blends Bottom line: There are no Drop-Ins Take the time to do it right
14 HFC Component Comparison R-22 Retrofits are blends containing two or more HFC components R-32 R-125 R-143a R-134a Cond. Pressures (%) V. R. Capacity (%) COP (%) Mass Flow Rate (%) Discharge Temps ( F) GWP (100 year) Flammability A2L A1 A2L A1 MO / AB Solubility Very Poor Very Poor Poor Very Poor Relative to R-22, Standard 105 F Condenser, 25 F Evaporator, 10 F of Superheat & Subcooling GWP from the IPCC AR5
15 Blend Issues Temperature Glide Single Component Temperature Superheated Boiling/Condensing Subcooled Evaporating Condensing
16 Blend Issues Temperature Glide Single Component Temperature Superheated Boiling/Condensing Subcooled Evaporating Zeotropic Blend Condensing Temperature Boiling/Condensing Glide Position in heat exchanger
17 Example Blend Compositions (weight %) R-32 R-125 R-143a R-134a R-290 R-600a R-600 R-601a Lubricant R-404A R-407A R-407C R-407F R-417A R-417B R-421A Added R-421B Added R-422A R-422B R-422C R-422D R-424A R-427A R-428A R-434A R-438A R-507A
18 Compositions of Some Retrofit Options (wt%) R-125 R-134a R-143a R-32 Hydrocarbons R-600 R-600a R-601a Forane 427A Forane 407A Forane 407C R-422D R-438A
19 GWP Comparison of R-22 Replacements Global Warming Potential GWP from IPCC AR4 1,700 R-22 GWP = 1,810 2,300 Global Warming Potential (100 Yr.) 2,730 4,000 R-427A R-407C R-407A R-407F R-438A R-417A R-421A R-424A R-422B R-404A R-507 R-422D R-422A R-422C R-428A R-434A R-421B R-417B R-407B
20 Refrigerant Classifications Lower Toxicity OEL 500 ASHRAE Standard 34 Classifies refrigerants based on flammability and toxicity Determines how refrigerants are treated in codes and standards Non-Flammable Mildly Flammable Flammable Highly Flammable No flame LFL > 0.1 kg/m 3 and HOC < 19 MJ/kg LFL 0.1 kg/m 3 propagation BV 10 cm/s BV > 10 cm/s HOC 19 MJ/kg A1 A2L A2 A3 R-11 R-12 R-22 R-134a R-410A R-404A R-427A R-407A R-407C R-4507A R-408A others R-32 R-143a R-152a R-290: Propane R-600: Butane R-600a: Isobutane Higher Toxicity OEL < 500 B1 B2L B2 B3 R-123 NH3
21 R-22 Retrofit Metrics* Capacity (%) COP (%) Mass Flow (%) Discharge P (psi) Suction P (psi) Discharge T ( F) R-407F +5 R-507A +5 R-428A R-404A R-407A 0 0 R-407C -5 R-421B R-422A -5 R-434A R-422C R-417B R-427A R-438A R-422D R-421A R-422B R-424A R-417A R-407C -3 R-427A -3 R-407A R-417A R-438A R-421A R-424A R-422B R-407F R-507A R-422D R-404A R-417B -9 R-434A -9 R-422C R-422A R-421B R-428A R-428A R-421B R-422A R-422C R-417B +45 R-434A R-422D R-507A R-404A R-422A R-404A R-407F R-422B R-421A R-421B R-422C R-424A R-417A R-417B R-407A R-434A R-438A R-407C R-427A R-407A R-407C 0 0 R-407F R-428A R-507A R-422D R-427A 0 R-438A 0 R-422B -15 R-421A -15 R-424A R-417A R-428A R-507A R-404A R-422A R-421B R-422C R-434A R-407F R-417B R-407A 0 0 R-407C R-422D R-427A -5 R-438A -5 R-422B R-421A R-424A R-417A R-407F R-407C -15 R-407A R-427A R-438A R-417AR-404AR-424A R-421A R-507A R-421B R-434A R-422B R-422D R-428A -45 R-417B -45 R-422A R-422C Capacity (%) COP (%) Mass Flow (%) Discharge P (psi) Suction P (psi) Discharge T ( F) *Standard Cycle 105 F Condenser, 25 F Evaporator, 10 F Subcooling & 10 F Superheat
22 R-22 Retrofit Metrics* Capacity (%) COP (%) Mass Flow (%) Discharge P (psi) Suction P (psi) Discharge T ( F) R-407A R-407A 0 0 R-407C -5-5 R-427A R-407C -3 R-427A -3 R-407A R-427A R-407A R-407C R-407C R-427A R-407A 0 0 R-407C R-427A R-407C -15 R-407A R-427A Capacity (%) COP (%) Mass Flow (%) Discharge P (psi) Suction P (psi) Discharge T ( F) *Standard Cycle 105 F Condenser, 25 F Evaporator, 10 F Subcooling & 10 F Superheat
23 R-22 Retrofit Recommendations Forane 407C Forane 407A Forane 427A Applications Air Conditioning MT & LT Refrigeration Air Conditioning MT & LT Refrigeration Advantages Close match in AC Close match in Refrigeration Close match across range of conditions TXV Change NO NO NO Lubricant POE POE POE / (MO / AB)* * Oil change not needed for many installations
24 The Easy Retrofit TM - Forane 427A
25 Oil Management Issues HFC refrigerants are not miscible in mineral oil or alkylbenzene Hydrocarbons sometimes use to improve oil return, but are highly flammable Use of certain HFC components can improve oil return, such as with R-427A Oil can log in the evaporator and degrade performance Decreased capacity and efficiency Loss in capacity may result in undersized equipment after retrofit System layout is important for proper oil management: Compressor on roof feeding evaporators below Systems with long risers or pipe runs Systems with receivers Options in cases of oil return issues: Adding POE oil to the mineral oil/ab or doing a complete oil change If oil is accessible then an oil change is a proper procedure for a good retrofit If oil is not accessible then stay with R-22 or upgrade to a new system
26 A Few Recommendations with R-427A Change the Oil Long line sets Compressor above coil(s) Systems with vertical risers Systems that you are servicing under contract No Oil Change Short, horizontal line sets Packaged or close-coupled systems Systems not under warranty Favorable evaporator layout and position Oil Change Challenges Solvency of POE Need for filter changes Labor and Expenses Oil change is time consuming Flushes Multiple flushes often not required System setup The oil is not always easily accessible General criteria only. A lubricant change may not be required but POE is always recommended for optimal performance
27 Effect of Lubricant on Performance Tests conducted with Forane 427A, R-438A, R-422D Forane 427A provided best performance across range of conditions Using POE increases COP and Capacity COP (relative to max) R-427A / MO R-427A / POE R-422D / MO R-422D / POE R-438A / MO R-438A / POE Capacity (relative to max) F 25 F 50 F 0 F 25 F 50 F Box Temperature ( o F)
28 CASE STUDIES Air-Conditioning Without Oil-Change: Solar Supply Warehouse, Lake Charles, LA Refrigeration With Oil-Change: Sherm s Thunderbird, Roseburg, OR
29 Retrofit to Forane 427A No Oil Change Solar Supply Warehouse Office (Lake Charles, LA) Application: Air Conditioning (3.5-ton heat pump) Mineral Oil: No oil change Filter-drier and Schrader valve caps and cores were replaced Results: No significant differences in system performance observed Operating pressures with Forane 427A closely matched those with R-22 Compressor ran at lower discharge temperatures
30 Retrofit to Forane 427A Oil Change to POE Sherm s Thunderbird (Roseburg, OR) Application: Supermarket Refrigeration (MT & LT) 3 systems: low-temp, frozen food, deli cases & heat reclaim Mineral Oil replaced with POE No replacement of TXVs Results: Reduced operating cost 7% reduction Case temperatures maintained at desired setpoints Low discharge temperatures
31 Summary R-22 Phase-out: Don t Panic Production/Importation of virgin R-22 will cease in 2020 R-22 equipment can still be serviced with existing R-22 after 2020 You have options for your equipment: 1. Continue to service equipment with R Perform a retrofit to the existing equipment 3. Replace the old equipment for new When performing a retrofit, do your homework Be sure the installation is right for a retrofit Choose a retrofit that closely matches R-22 like Forane 427A Choose a retrofit that minimizes the work required like Forane 427A Take the time to do it right
32 Forane PT Calculator App
33 R-22 Retrofit Resources For more information on Arkema s R-22 Retrofit Solutions, please visit our website at Other useful links: Arkema s N.A. Website: Forane Refrigerant Training: Forane PT App Now supports 8 languages! itunes: Androids: earch_result#?t=w251bgwsmswyldesimnvbs5gb3jhbmuurm9yyw5lil0 Technical Service: THANK YOU FOR YOUR TIME!
Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems
Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems Dr. Charles C. Allgood 1, C. Curtis Lawson 2 1 DuPont Fluorochemicals, Wilmington, DE, USA E-mail: [email protected]
SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS
SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS 2009 Tecumseh Products Company. All rights reserved. Page 1 of 8 Refrigerant R22 is widely used for residential and commercial air conditioning, as
RS-52 (R428A) RS-52: PHYSICAL PROPERTIES RS-52 R502 Molecular weight 107.5 111.6 Temperature glide o C 0.5 0.2 Boiling point (1 atm)
RS-52 (R428A) COMPOSITION % HFC 125 77.5 HFC 143a 20.0 R600a 1.9 R290 0.6 HCFC replacement Temperature glide R22, 502 & interim blends Approximately 0.8 o C Drop-in or long term Both Lubricant MO/AB/POE
RS-24 (R426A): Q & A
RS-24 (R426A): Q & A 1 Q: What is RS-24? A: RS-24 is a non ozone depleting Drop-in replacement for R12 in all applications including mobile air conditioning. 2 Q: Yes, but what does RS-24 contain? A: RS-24
Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 21 Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems
Low GWP Replacements for R404A in Commercial Refrigeration Applications
Low GWP Replacements for R404A in Commercial Refrigeration Applications Samuel YANA MOTTA, Mark SPATZ Honeywell International, 20 Peabody Street, Buffalo, NY 14210, [email protected] Abstract
HCFC-22 Retrofits. There has been increased emphasis on retrofitting R-22
HCFC-22 Retrofits A c l o s e l o o k a t t h e r e f r i g e r a n t / l u b r i c a n t i n t e r a c t i o n s. B y S a m u e l F. Y a n a M o t t a, E l i z a b e t D. V e r a B e c e r r a, R o n
RS-44 (R424A) : Q & A
RS-44 (R424A) : Q & A 1 Q: What is RS-44? A: RS-44 is a non ozone depleting Drop-in replacement for R22 in most applications. 2 Q: Yes, but what does RS-44 contain? A: RS-44 is a blend of HFC134a, HFC125,
THE REPLACEMENT OF R-22
ENGLISH TRANSLATION OF ARTICLE IN FRIO-CALOR AIRE ACONDICIONDAO BY GAS-SERVEI, S.A JUNE 2010 THE REPLACEMENT OF R-22 Courtesy of D. Lluis Giralt Lopez (Chemical Engineering Industrial) Gas Technical Department
Low-GWP Refrigerants for Air Conditioning and Refrigeration Applications. Samuel F Yana Motta
Low-GWP Refrigerants for Air Conditioning and Refrigeration Applications Samuel F Yana Motta Refrigerants for Stationary Applications HONEYWELL CONFIDENTIAL N Series L Series Current Product Reduced GWP
How To Design A Refrigeration System
AIRAH Refrigeration (in HVAC) Back to Basics For the First Time Terms of Reference What this session is NOT about Detailed Refrigeration Design Detailed analysis of various Refrigants properties Comparison
Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems
Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems William M. Corcoran, George Rusch, Mark W. Spatz, and Tim Vink AlliedSignal, Inc. ABSTRACT
REFRIGERANT REFERENCE GUIDE
REFRIGERANT REFERENCE GUIDE WORLWIDE REFRIGERANT SUPPLIER 2004 FOURTH EDITION 2004 DISCLAIMER This publication is designed to provide accurate and authoritative information. It is not to be construed as
R407C GUIDELINES FOR UTILIZATION OF. DATE: August 2009 REFERENCE DOCUMENT NO. RD-0005-E GUIDELINES FOR UTILIZATION OF R407C
GUIDELINES FOR UTILIZATION OF R407C 2009 Tecumseh Products Company. All rights reserved. Page 1 of 6 After many years of testing and investigation, R407C is recognized as a suitable alternative refrigerant
Scroll compressors for Low GWP Heat Pumps using R290 natural refrigerant. Pierre Ginies, Next Heat Pump Generation 2015 p.ginies@danfoss.
Scroll compressors for Low GWP Heat Pumps using R290 natural refrigerant Pierre Ginies, Next Heat Pump Generation 2015 [email protected] Danfoss Commercial Compressors Leading compressor R&D and manufacturing
Refrigeration Basics 101. By: Eric Nelson
Refrigeration Basics 101 By: Eric Nelson Basics Refrigeration is the removal of heat from a material or space, so that it s temperature is lower than that of it s surroundings. When refrigerant absorbs
Technical Note: Comparing R407C and R410A as Alternatives for R22. A Technical Note from the Experts in Business-Critical Continuity
Technical Note: Comparing R407C and R410A as Alternatives for R22 A Technical Note from the Experts in Business-Critical Continuity Purpose The purpose of this document is to provide a brief overview of
A Comparison of an R22 and an R410A Air Conditioner Operating at High Ambient Temperatures
R2-1 A Comparison of an R22 and an R410A Air Conditioner Operating at High Ambient Temperatures W. Vance Payne and Piotr A. Domanski National Institute of Standards and Technology Building Environment
Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions
Refrigerant Changeover Guidelines R-22 to R-407C Leading the Industry with Environmentally Responsible Refrigerant Solutions Copeland does not CFC advocate the wholesale changeover of HCFC HCFC refrigerants
Commercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1:
PART 1: CO 2 Commercial refrigeration has been in the environmental spotlight for more than a decade, especially as leakage studies have revealed the true effects of hydrofluorocarbon (HFC) emissions.
TEST REPORT #44. System Drop-in Tests of Refrigerant R-32 in Single Packaged Vertical Heat Pump (SPVH)
Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP) TEST REPORT #44 System Drop-in Tests of Refrigerant R-32 in Single Packaged
ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014
ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014 Explanation of the refrigeration cycle. Compressors. Benefits and operating characteristics. -Reciprocating
REFRIGERANT 410A. Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois 60016. Information compiled by Frank Prah, CMS
Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois 60016 REFRIGERANT 410A Information compiled by Frank Prah, CMS INTRODUCTION Recently a new refrigerant, R-410A, has been formulated
P08 Köldmedier med låg växthuseffekter
P08 Köldmedier med låg växthuseffekter Pavel Makhnatch Tranås, 17-18 May Reference: IPCC, 2013 3 4 5 Growth of climate change commitments from HFC banks and emissions Reference: Velders et al. 2014 6
Refrigerants for Residential and Commercial Air Conditioning Applications
Refrigerants for Residential and Commercial Air Conditioning Applications October 2008 Table of contents Executive summary 2 Introduction and background 3 Environmental drivers 4 Regulatory update 8 Criteria
Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions
Refrigerant Changeover Guidelines R-22 to R-407C Leading the Industry with Environmentally Responsible Refrigerant Solutions Emerson Climate CFC Technologies, Inc. does not advocate the HCFC wholesale
EU f-gas regulation EN 517/2014.
F-gas regulation EU f-gas regulation EN 517/2014. Helping you meet your environmental obligations. 02 EU f-gas regulation EU f-gas regulation. Reducing your environmental impact. The updated f-gas regulation
Troubleshooting HVAC/R systems using refrigerant superheat and subcooling
Troubleshooting HVAC/R systems using refrigerant superheat and subcooling Application Note Troubleshooting and servicing refrigeration and air conditioning systems can be a challenging process for both
TEST REPORT #31. System Drop-in Test of Refrigerant R-32 in Split Air-conditioning System
Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP) TEST REPORT #31 System Drop-in Test of Refrigerant R-32 in Split Air-conditioning
PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM WITH R404A, R407C AND R410A
Int. J. Mech. Eng. & Rob. Res. 213 Jyoti Soni and R C Gupta, 213 Research Paper ISSN 2278 149 www.ijmerr.com Vol. 2, No. 1, January 213 213 IJMERR. All Rights Reserved PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION
Refrigerant identification and equipment issues in relation to HCFC phase-out. Ole Reinholdt Nielsen
Refrigerant identification and equipment issues in relation to HCFC phase-out Ole Reinholdt Nielsen Belize, March 3, 2010 Outline Brief introduction; Refrigerant identification: Historically; Options for
Engineers Newsletter. HVAC Refrigerants: A Balanced Approach. providing insights for today s hvac system designer. volume 40 2. Refrigerant History
providing insights for today s hvac system designer Engineers Newsletter volume 40 2 HVAC Refrigerants: A Balanced Approach One of the constant themes throughout the history of the HVAC industry is the
It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.
The System Evaluation Manual and Chiller Evaluation Manual have been revised and combined into this new book; the Air Conditioning and Refrigeration System Evaluation Guide. It will be available soon as
Refrigerant Changeover Guidelines HCFC R-22 to HFC R-404A/R-507. Leading the Industry with Environmentally Responsible Refrigerant Solutions
Refrigerant Changeover Guidelines HCFC R-22 to HFC R-404A/R-507 Leading the Industry with Environmentally Responsible Refrigerant Solutions Copeland does not advocate the wholesale changeover of HCFCs
HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation. Richard Lord Carrier Fellow
HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation Richard Lord Carrier Fellow HVAC Industry Challenges and Issues Ozone Deletion Global Warming
Ground-breaking conversion of critical Data Room WaterChiller from R22 to R422D / MO29
Ground-breaking conversion of critical Data Room WaterChiller from R22 to R422D / MO29 A refrigerant retrofit project, involving the conversion of a large Data Room cooling system from R22 to R422D (DuPont
Refrigerant Changeover Guidelines R-502 to R-402A/R-408A. Leading the Industry with Environmentally Responsible Refrigerant Solutions
Refrigerant Changeover Guidelines R-502 to R-402A/R-408A Leading the Industry with Environmentally Responsible Refrigerant Solutions Copeland does not advocate the wholesale CFC changeover of CFC HCFC
Planning for the ban on R22 in building air conditioning
- ACHPI 32 Planning for the ban on R22 in building air conditioning Those responsible for cooling and heating commercial properties are under increased pressure to improve energy efficiency and negotiate
Part A: Fluid properties
UNEP Ozone Secretariat UNEP Ozone Secretariat Background Workshop Material on HFC for management: HFC Workshop, technical 2015 issues Bangkok, 20 and 21 April 2015 FACT SHEET 15 Glossary of terms and technical
Any Service Technician Can Fix It A Good Service Technician Can Figure Out What s Wrong With It.
I Dave s Statement If the thermostat calls for cooling, and the furnace fan is running properly, and the coil airflow is adequate, and the condenser fan is running properly, and the condenser airflow is
System Diagnosis. Proper vehicle diagnosis requires a plan before you start
System Diagnosis Proper vehicle diagnosis requires a plan before you start Following a set procedure to base your troubleshooting on will help you find the root cause of a problem and prevent unnecessary
Guide to good leak testing
Page 0 Guide to good leak testing The Institute of Refrigeration, working with the Carbon Trust, brings you REAL Zero Refrigerant Emission and Loss Zero. The aim of this project is in the title zero refrigerant
Commercial CO2 Refrigeration Systems. Guide for Subcritical and Transcritical CO2 Applications
Commercial CO2 Refrigeration Systems Guide for Subcritical and Transcritical CO2 Applications 2 Contents Chapter 1. Introduction 4 Chapter 2. CO 2 Basics and Considerations as a Refrigerant 5 Section 1.
Mohan Chandrasekharan #1
International Journal of Students Research in Technology & Management Exergy Analysis of Vapor Compression Refrigeration System Using R12 and R134a as Refrigerants Mohan Chandrasekharan #1 # Department
ADVANCES IN SUPERMARKET REFRIGERATION SYSTEMS
ADVANCES IN SUPERMARKET REFRIGERATION SYSTEMS Van D. Baxter, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6070 ABSTRACT Present supermarket refrigeration systems require very large refrigerant charges
Characteristics of Evaporators
Characteristics of Evaporators Roger D. Holder, CM, MSME 10-28-2003 Heat or Energy In this paper, we will discuss the characteristics of an evaporator coil. The variance of the operational condenses of
Increasing the evaporation temperature with the help of an internal heat exchanger
Increasing the evaporation temperature with the help of an internal heat exchanger A. TAMBOVTSEV (a), H. QUACK (b) (a,b) Technische Universität Dresden, D-01062, Dresden, Germany (a) Fax: (+49351) 463-37247,
SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS
SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES After studying this unit, the reader should be able to explain the purpose of the condenser in a refrigeration system. describe differences
Todd M. Rossi, Ph.D. President
Residential Air Conditioning Fault Detection and Diagnostics (FDD) and Protocols to Support Efficient Operation DOE - Building America Program Residential Buildings Integration Meeting - July 20-22, 2010
Information on New Refrigerant (R-1234yf) for A/C Service
Information on New Refrigerant (R-1234yf) for A/C Service 2013 Cadillac ATS, XTS This bulletin is being revised to include procurement and labeling information for recovery cylinders to be used with GE-50957-Contaminated
Purpose of Refrigeration
Refrigeration Outline Purpose of refrigeration Examples and applications Choice of coolant and refrigerants Phase diagram of water and CO 2 Vapor compression refrigeration system Pressure enthalpy diagram
Lesson. 11 Vapour Compression Refrigeration Systems: Performance Aspects And Cycle Modifications. Version 1 ME, IIT Kharagpur 1
Lesson Vapour Compression Refrigeration Systems: Performance Aspects And Cycle Modifications Version ME, IIT Kharagpur The objectives of this lecture are to discuss. Performance aspects of SSS cycle and
TECHNICAL ANNEX. Alternatives to HCFCs/HFCs in unitary air conditioning equipment at high ambient temperatures. November 2014
TECHNICAL ANNEX Alternatives to HCFCs/HFCs in unitary air conditioning equipment at high ambient temperatures November 2014 Authors: Bastian Zeiger, Barbara Gschrey, Winfried Schwarz Öko-Recherche, Frankfurt/Main,
Energy Procedia Energy 00 Procedia (2011) 000 000 14 (2012) 56 65
Available online at www.sciencedirect.com Available online at www.sciencedirect.com Energy Procedia Energy 00 Procedia (2011) 000 000 14 (2012) 56 65 Energy Procedia www.elsevier.com/locate/procedia ICAEE
Heat Recovery In Retail Refrigeration
This article was published in ASHRAE Journal, February 2010. Copyright 2010 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. Posted at www.ashrae.org. This article may not
International Refrigerant Standards and their Influence on the Global HVAC Industry and Refrigerant Replacement
International Refrigerant Standards and their Influence on the Global HVAC Industry and Refrigerant Replacement Tom Watson, P.E. Fellow ASHRAE, Life Member President ASHRAE Issues Choosing a refrigerant
How Ground/Water Source Heat Pumps Work
How Ground/Water Source s Work Steve Kavanaugh, Professor Emeritus of Mechanical Engineering, University of Alabama Ground Source s (a.k.a. Geothermal s) are becoming more common as the costs of energy
Air Conditioning 101. STN Presentation AC101
Air Conditioning 101 What is Refrigeration? Refrigeration is Cooling by the Removal of Heat Heat is Measured In BTU s A BTU is a British Thermal Unit It is the Amount of Heat to Raise One Pound of Water,
Skills Canada National Competition Instructions and Competition Details 38 Refrigeration and Air Conditioning / Post - Secondary May 27-30, 2015 -
Skills Canada National Competition Instructions and Competition Details / Post - Secondary May 27-30, 2015 - Saskatoon 1. Test Project Details This project is designed to test the range of skills used
High School Graduation years 2013, 2014, 2015. Unit/Standard Number
1 Secondary Task List 100 INTRODUCTION TO HVAC 101 Identify HVAC systems. 102 Describe career opportunities in the HVAC profession. 103 Demonstrate awareness of the occupational requirements. 104 Explain
2016 HVAC Test and Repair Application Specifications
2016 HVAC Test and Repair Application Specifications HVAC Testing and Repair Measure: Performed on (2 ton and up) existing (DX) packaged or split systems - retrofit There are three separate incentive categories
Commercial CO 2 Refrigeration Systems
Commercial CO 2 Refrigeration Systems Guide for Subcritical and Transcritical CO 2 Applications 2 Contents Chapter 1. Introduction 4 Chapter 2. CO 2 Basics and Considerations as a Refrigerant 5 Section
123 street Salt Lake City, Utah 84092
Salt Lake City, Utah 84092 Prepared for: Sample AC inspection Prepared by: Page 1 of 8 Table of Contents Definitions 2 General Information 2 Air Conditioning 3 Heating System 6 Summary 8 Page 2 of 8 Definitions
Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet
Perkins Statewide Articulation Agreement Documentation item: Secondary Task List Coversheet The Secondary School agrees to: A. Implement the approved PDE Program(s) of Study. B. Provide assessment of student
Certified HVAC Audit Report Key Takeaways and Implications. Created for: Pets On the Go 445 Logging Road, Building 3 Yardley, PA-19034
Certified HVAC Audit Report Key Takeaways and Implications Created for: Pets On the Go 44 Logging Road, Building 3 Yardley, PA-9034 May, 0 Executive Summary Proposal Generator Demo aims to reduce your
Chapter 2 P-H Diagram Refrigeration Cycle Analysis & Refrigerant Flow Diagram
Chapter 2 P-H Diagram Refrigeration Cycle Analysis & Refrigerant Flow Diagram Copy Right By: Thomas T.S. Wan 温 到 祥 著 Sept. 3, 2008 All rights reserved Industrial refrigeration system design starts from
Impacts of Refrigerant Charge on Air Conditioner and Heat Pump Performance
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2010 Impacts of Refrigerant Charge on Air Conditioner and Heat Pump Performance
Topics: Refrigerant Proliferation, Global Drivers/Regulation
Recent Developments In Refrigerants For Air-Conditioning And Refrigeration Systems Rajan Rajendran Topics: Refrigerant Proliferation, Global Drivers/Regulation Life Cycle Climate Performance Approach Available
Evaporator Coil Installation Instructions
Part # 96654008 July 2010 Evaporator Coil Installation Instructions A-Coil Page 4 Multi-position A-Coil Page 4-7 Slab Coil Page 5 Horizontal A-Coil Top Connection Page 5 Horizontal A-Coil Side Connection
Certification in the safe and efficient use of alternative refrigerants
Certification in the safe and efficient use of alternative refrigerants Dubai, 29th Oct 2014 Marco Buoni VicePresident, AREA Air Conditioning & Refrigeration European contractors Association (www.area-eur.be)
Why and How we Use Capacity Control
Why and How we Use Capacity Control On refrigeration and air conditioning applications where the load may vary over a wide range, due to lighting, occupancy, product loading, ambient weather variations,
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
THEORETICAL AND EXPERIMENTAL EVALUATION OF AUTOMOBILE AIR-CONDITIONING SYSTEM USING R134A
THEORETICAL AND EXPERIMENTAL EVALUATION OF AUTOMOBILE AIR-CONDITIONING SYSTEM USING R134A Jignesh K. Vaghela Assistant Professor, Mechanical Engineering Department, SVMIT, Bharuch-392001, (India) ABSTRACT
R-32. The next generation refrigerant for air conditioners and heat pumps. Superior energy efficiency and low GWP
R-32 The next generation refrigerant for air conditioners and heat pumps Superior energy efficiency and low GWP HFC phase-down and the introduction of R32 The European phase-down of HFCs, which will see
Energy Efficiency in HVAC equipment applications
Energy Efficiency in HVAC equipment applications All Seasons CLIMATE COMFORT Heating Air Conditioning Applied Systems Workshop 6 September 2012 Midrand. Refrigeration PUBLIC All Seasons CLIMATE COMFORT
2004 Standard For Performance Rating Of Positive Displacement Refrigerant Compressors And Compressor Units
2004 Standard For Performance Rating Of Positive Displacement Refrigerant Compressors And Compressor Units ANSI/AHRI Standard 540 (formerly ARI Standard 540) IMPORTANT SAFETY RECOMMENDATIONS ARI does not
R-32. The next generation refrigerant for air conditioners and heat pumps
R-32 The next generation refrigerant for air conditioners and heat pumps Daikin is the first company in the world to launch heat pumps and air conditioners charged with R-32. This refrigerant has several
The efficient heat pump
The efficient heat pump KCP&L has worked hard to build one of the best reliability records in the industry and we want to help you make the most of the energy we provide. That s why we offer information
Automobile Air Conditioning Primer
Automobile Air Conditioning Primer An air conditioner is basically a refrigerator without the insulated box. It uses the evaporation of a refrigerant, like Freon, to provide cooling. The mechanics of the
InvestSmart Business Energy Upgrades Refrigeration Solutions Equipment Catalog 01/01/2015
2015 InvestSmart Business Energy Upgrades 01/01/2015 Table of Contents 1...1-1 1.1 Anti-Sweat Heater Controls... 1-1 1.2 Door Gaskets for Glass and Solid Doors... 1-2 1.3 High-Efficiency Doors for Low
UNIT 2 REFRIGERATION CYCLE
UNIT 2 REFRIGERATION CYCLE Refrigeration Cycle Structure 2. Introduction Objectives 2.2 Vapour Compression Cycle 2.2. Simple Vapour Compression Refrigeration Cycle 2.2.2 Theoretical Vapour Compression
Update on a Low GWP Refrigerant: Fluid H
Update on a Low GWP Refrigerant: Fluid H Mark W. Spatz Global Leader Refrigerant Technology Honeywell Fluorine Products SAE 2007 Alternatives Refrigerant Systems Symposium July 17-19, 2007 1 Agenda Material
Refrigeration and air-conditioning. Alfa Laval s offering at a glance
Refrigeration and air-conditioning Alfa Laval s offering at a glance At Alfa Laval green is cool Alfa Laval products are also installed on oil platforms, in power plants, onboard ships, in the mechanical
MAXIMUM HEAT LOAD TEMPERATURE TESTING ( Differential Temperature Testing )
MAXIMUM HEAT LOAD TEMPERATURE TESTING ( Differential Temperature Testing ) The Concept Maximum Heat Load Temperature Testing is a powerful air-conditioning diagnostic and evaluation technique. It is also
D A T A S H E E T. TX6 Thermo Expansion Valves. Alco Controls TX6. Features. Introduction. Construction
ALCO s series of Thermo -Expansion Valves are designed for air conditioning, chillers, rooftops, close control, A/C transportation, heat pumps, industrial cooling process and refrigeration applications.
D A T A S H E E T. TX3 Thermo Expansion Valves. Alco Controls TX3. Features. Introduction. Description of bulb charges
ALCO s TX3 series of Thermo -Expansion Valves are designed for air conditioning, heat pumps and commercial refrigeration applications. The TX3 is ideal for those applications requiring hermetic / compact
A car air-conditioning system based on an absorption refrigeration cycle using energy from exhaust gas of an internal combustion engine
A car air-conditioning system based on an absorption refrigeration cycle using energy from exhaust gas of an internal combustion engine G Vicatos J Gryzagoridis S Wang Department of Mechanical Engineering,
REFRIGERATION (& HEAT PUMPS)
REFRIGERATION (& HEAT PUMPS) Refrigeration is the 'artificial' extraction of heat from a substance in order to lower its temperature to below that of its surroundings Primarily, heat is extracted from
Preventive Maintenance Strategies and Technologies Can Pave the Path for Next Generation Rooftop HVAC systems
Preventive Maintenance Strategies and Technologies Can Pave the Path for Next Generation Rooftop HVAC systems Ramin Faramarzi, P.E. Technology Test Centers October 14, 2014 Overview 1. Why is HVAC maintenance
PG Student (Heat Power Engg.), Mechanical Engineering Department Jabalpur Engineering College, India. Jabalpur Engineering College, India.
International Journal of Emerging Trends in Engineering and Development Issue 3, Vol. (January 23) EFFECT OF SUB COOLING AND SUPERHEATING ON VAPOUR COMPRESSION REFRIGERATION SYSTEMS USING 22 ALTERNATIVE
SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
HFC-free refrigeration technology for the retail business in the Netherlands
HFC-free refrigeration technology for the retail business in the Netherlands (Currently a technical revolution is taking place in the refrigeration industry) BRUNEL University Bart van der Wekken 23rd
Analysis of Alternative Refrigerants to HCFC-22
2014 3rd International Conference on Informatics, Environment, Energy and Applications IPCBEE vol.66 (2014) (2014) IACSIT Press, Singapore DOI: 10.7763/IPCBEE. 2014. V66. 34 Analysis of Alternative Refrigerants
THE POSSIBILITY OF USING LIQUIFIED PETROLEUM GAS IN DOMESTIC REFRIGERATION SYSTEMS
www.arpapress.com/volumes/vol9issue3/ijrras_9_3_02.pdf THE POSSIBILITY OF USING LIQUIFIED PETROLEUM GAS IN DOMESTIC REFRIGERATION SYSTEMS Zainal Zakaria 1 & Zulaikha Shahrum 2 Department of Gas Engineering,
Chapter 3.4: HVAC & Refrigeration System
Chapter 3.4: HVAC & Refrigeration System Part I: Objective type questions and answers 1. One ton of refrigeration (TR) is equal to. a) Kcal/h b) 3.51 kw c) 120oo BTU/h d) all 2. The driving force for refrigeration
LOBOY 16 AIR CONDITIONERS
INSTRUCTION MANUAL FOR: LOBOY 16 AIR CONDITIONERS McLean Midwest Corp. dba: McLean Cooling Technology 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleancoolingtech.com
Elements Elements describe the essential outcomes.
AURETU005 Application Competency Field Unit Sector Elements Elements describe the essential outcomes. Retrofit and modify air conditioning and HVAC systems This unit describes the performance outcomes
Patech. Our Conviction. Quality Service Innovation PATECH FINE CHEMICALS CO., LTD
Our Conviction Quality Service Innovation Product Categories Refrigeration Lubricants POE for HFC Refrigerants POE for HCFC Refrigerants POE for HFO Refrigerants Special Plasticizers Nontoxic Plasticizer
How does solar air conditioning work?
How does solar air conditioning work? In a conventional air conditioning system; The working fluid arrives at the compressor as a cool, low-pressure gas. The compressor is powered by electricity to squeeze