THREE-BEAD-BALUN REFLECTION BRIDGE 250 KHz to 1.5 GHz Sam Wetterlin 9/22/08

Similar documents
S-Parameters and Related Quantities Sam Wetterlin 10/20/09

TESTS OF 1 MHZ SIGNAL SOURCE FOR SPECTRUM ANALYZER CALIBRATION 7/8/08 Sam Wetterlin

Introduction to the Smith Chart for the MSA Sam Wetterlin 10/12/09 Z +

MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER

R3765/67 CG Network Analyzer

Measurement of Inductor Q with the MSA Sam Wetterlin 3/31/11. Equation 1 Determining Resonant Q from Inductor Q and Capacitor Q

Experiment 7: Familiarization with the Network Analyzer

VNA Operating Guide. for the MSA 2/1/10

Impedance Matching of Filters with the MSA Sam Wetterlin 2/11/11

Comparison of Vector Network Analyzer and TDA Systems IConnect Generated S-Parameters

1. The Slotted Line. ECE 584 Microwave Engineering Laboratory Experiments. Introduction:

Crosstalk effects of shielded twisted pairs

Utilizing Time Domain (TDR) Test Methods For Maximizing Microwave Board Performance

WHY DIFFERENTIAL? instruments connected to the circuit under test and results in V COMMON.

Capacitor Self-Resonance

Agilent Measuring Noninsertable Devices

Probes and Setup for Measuring Power-Plane Impedances with Vector Network Analyzer

Subject: Glenair MIL-PRF Conduit Surface Transfer Impedance Test

MEASUREMENT SET-UP FOR TRAPS

Understanding Power Splitters

MEASUREMENT OF CRYOGENIC PERFORMANCE OF 4-8 GHz PAMTECH ISOLATORS S/N Juan Daniel Gallego Isaac López Fernández Carmen Diez González

Cable Impedance and Structural Return Loss Measurement Methodologies

Understanding Power Splitters

The N2PK Vector Network Analyzer (N2PK VNA) Original by Paul Kiciak, N2PK, 2007 * (*Pages edited or added by VE7WRS, 2009)

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

RF Network Analyzer Basics

Application Note Noise Frequently Asked Questions

Balun Parameter Definitions & Measurement May 2004

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

Automatic compression measurement using network analyzers

2. The Vector Network Analyzer

Field Calibration Software

0HDVXULQJWKHHOHFWULFDOSHUIRUPDQFH FKDUDFWHULVWLFVRI5),)DQGPLFURZDYHVLJQDO SURFHVVLQJFRPSRQHQWV

Agilent Balanced Measurement Example: Differential Amplifiers

Constructing a precision SWR meter and antenna analyzer. Mike Brink HNF, Design Technologist.

Network Analyzer Operation

Low Cost, Triple Balanced, LTCC Mixer

CONDUCTED EMISSION MEASUREMENT OF A CELL PHONE PROCESSOR MODULE

Agilent PN RF Component Measurements: Amplifier Measurements Using the Agilent 8753 Network Analyzer. Product Note

spinner Measurement & Calibration equipment for network analyzers

LAB 7 MOSFET CHARACTERISTICS AND APPLICATIONS

Impedance 50 (75 connectors via adapters)

1000BASE-T1: 3-Port Conversion/Balance Measurement for Cables and Components

Measuring Impedance and Frequency Response of Guitar Pickups

Agilent 8757D Scalar Network Analyzer 10 MHz to 110 GHz

Operational Amplifier - IC 741

DRIVING LOOOONG CABLES

11: AUDIO AMPLIFIER I. INTRODUCTION

Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise

Chapter 12: The Operational Amplifier

One Port Network Analyzer

School of Engineering Department of Electrical and Computer Engineering

Chapter 7 Antenna measurements.

An Ethernet Cable Discharge Event (CDE) Test and Measurement System

Impedance Matching and Matching Networks. Valentin Todorow, December, 2009

Ultra640 SCSI Measured Data from Cables & Backplanes

ECE 435 INTRODUCTION TO THE MICROWAVE NETWORK ANALYZER

ZLPLL Local Oscillator

Agilent De-embedding and Embedding S-Parameter Networks Using a Vector Network Analyzer. Application Note

SAR ASSOCIATED WITH THE USE OF HANDS-FREE MOBILE TELEPHONES

EE 186 LAB 2 FALL Network Analyzer Fundamentals and Two Tone Linearity

Measuring RF Parameters of Networks Bill Leonard NØCU

Hendricks 41dB Step RF Attenuator

What are the Requirements for an Accurate DSL Line Simulator? Paradyne International, France

BJT Characteristics and Amplifiers

UNDERSTANDING NOISE PARAMETER MEASUREMENTS (AN )

Designing the NEWCARD Connector Interface to Extend PCI Express Serial Architecture to the PC Card Modular Form Factor

2 Port Parameters I 1. ECE145A/218A Notes Set #4 1. Two-ways of describing device: A. Equivalent - Circuit-Model

A Low Frequency Adapter for your Vector Network Analyzer (VNA)

Use and Application of Output Limiting Amplifiers (HFA1115, HFA1130, HFA1135)

Understanding Power Impedance Supply for Optimum Decoupling

Agilent Advanced impedance measurement capability of the RF I-V method compared to the network analysis method. Application Note

Tire pressure monitoring

Improving Network Analyzer Measurements of Frequency-translating Devices Application Note

RF-Microwaves formulas - 1-port systems

Frequency Response of Filters

Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD OF INSERTION LOSS MEASUREMENT

Some Measurements on DVB-T Dongles with E4000 and R820T Tuners:

Data Communications Competence Center

Broadband covering primary wireless communications bands: Cellular, PCS, LTE, WiMAX

Understanding SWR by Example

Monolithic Amplifier PMA2-43LN+ Ultra Low Noise, High IP3. 50Ω 1.1 to 4.0 GHz. The Big Deal

Telecommunication Line Protectors

Understanding Mixers Terms Defined, and Measuring Performance

LVDS Technology Solves Typical EMI Problems Associated with Cell Phone Cameras and Displays

Agilent Test Solutions for Multiport and Balanced Devices

Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers

The Antenna Balun. What is this thing and why do I need it?

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

Broadband covering primary wireless communications bands: Cellular, PCS, LTE, WiMAX

AVX EMI SOLUTIONS Ron Demcko, Fellow of AVX Corporation Chris Mello, Principal Engineer, AVX Corporation Brian Ward, Business Manager, AVX Corporation

Circuits with inductors and alternating currents. Chapter 20 #45, 46, 47, 49

Low Cost, Triple Balanced, LTCC Mixer

Digital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip.

Power Supplies. 1.0 Power Supply Basics. Module

Cable Analysis and Fault Detection using the Bode 100

Transistor Characteristics and Single Transistor Amplifier Sept. 8, 1997

Gigabit Ethernet (1000Base-T) H5004 Performance Data

Category 8 Cable Transmission Measurements Comparative Study between 4-port single wire measurements and 2-port balun measurements

Transcription:

THREE-BEAD-BALUN REFLECTION BRIDGE 250 KHz to 1.5 GHz Sam Wetterlin swetterlin@comcast.net 9/22/08 This paper presents a reflection bridge useful from 250 KHz to the neighborhood of 1.5 GHz. This bridge may be used in conjunction with a vector network analyzer (VNA), in which case the use of OSL calibration makes its performance about as good as one could want. It may also be used without calibration as a free-standing bridge, as discussed below. The schematic of the bridge is shown in the Appendix. It consists of three parts. The first part is an input attenuator, resistive bridge, and Mini-Circuits TC1-1-13 balun, all on a single PCB. The second part is a homemade balun made with RG-178 coax and three small ferrite beads. This balun is supported by a brass strip, which connects the first and second PCBs. The third part, contained on a second PCB, is an output attenuator and output connector. Because of the homemade balun, I refer to this as the Three-Bead-Balun Bridge. The finished bridge is shown in Figure 1. Figure 1 Assembled Three-Bead-Balun Bridge The ferrite beads are wound in fiberglass tape to keep the coax loops from shifting over time. Figure 2 shows a wound ferrite bead before wrapping. Figure 2-Ferrite bead with three turns of RG-178 (Passing once through the center counts as one turn)

Theory of Operation This bridge is a standard resistive bridge, using two 49.9 ohm resistors (close enough to 50 ohms for present purposes) as the upper legs of two voltage dividers, and using the device under test (DUT) as one lower leg, and an external 50 ohm load as the other lower leg. (The external load is used to preserve symmetry, which is useful at higher frequencies. Below a few hundred MHz, an on-board 49.9 ohm resistor can be used.) The reflection from the DUT is equal to the difference between the voltage on the DUT and on the 50-ohm reference. That difference is extracted by means of two successive baluns that function as common mode chokes to pass only the differential signal. The trick to obtaining decent performance is to have an effective balun. The TC1-1-13 balun by itself can only obtain directivity on the order of 20 db (more on directivity below), and also has weak performance below 5 MHz. Therefore, a second balun is used to further choke the common mode signal. Operation To use the bridge as a free-standing device to measure return loss, an input signal is connected to the input and the output is connected to a spectrum analyzer. An open standard is connected to the DUT port, and the output level is recorded. A short standard is then connected to the DUT port, and the output level recorded. The average of the open and short output levels becomes the reference level for that frequency. Various DUTs can then be attached to the DUT port, and the output level recorded. The difference between the DUT output and the reference level (obtained from averaging the open and short), expressed as a positive number in db, is the return loss of the DUT. That return loss measures the reflection received from the DUT relative to the signal sent to the DUT. For example, if the average of the open and short is -12 dbm, and the output with the DUT attached is -30 dbm, then the measured return loss is 30-12=18 dbm. (Error will be discussed later.) The bridge may be used with a vector network analyzer, in which case the use of Open-Short- Load (OSL) calibration will greatly improve accuracy. In addition, the VNA will be able to measure the phase of the reflection, which enables it to determine S-Parameters. Performance The quality of a reflection bridge is measured primarily by its directivity. Directivity is the amount of indicated return loss with a 50-ohm load. There should be no reflection in that situation, so the return loss should be infinite. For use with a VNA directivities of 20 db or better are acceptable, and anything over 30 is nearly perfect. For free-standing use without calibration, a directivity of 30 db will allow measurement of actual return losses up to 30 db, with some uncertainty (more on that later). Another measure of quality is the difference between the open and short output levels. Ideally, the magnitude of the reflection with an open and shorted DUT should be equal. A discrepancy between them may indicate that the DUT port does not present a good 50-ohm impedance to the DUT. When directivity is good and the open and short are close to one another, the DUT port impedance is likely very close to 50 ohms. Figure 3 shows the measured directivity and open/short for the Three-Bead-Balun Bridge. Note that while we subtract the short output from the open output to determine open/short, we are subtracting db levels so the resulting difference actually represents the ratio of the open and short

outputs. Hence the label open/short. Open/short magnitudes can be as high as 1.5 db without presenting a serious problem. Figure 3 Directivity and open/short Figure 3 shows that the directivity is good from 250 KHz to somewhere near 1.9 GHz, and is excellent from 1 MHz to 1 GHz. The open/short value exceeds 0.5 db at only two small peaks for frequencies below 1.4 GHz. The DUT port should ideally present a 50-ohm impedance to the DUT. If any part of the reflection reaching the DUT port is itself reflected back to the DUT, the measurement of the reflection will be inaccurate. When the bridge is used with a VNA, calibration will correct for this error, unless it becomes unreasonably large. For free-standing use of the bridge, DUT port return losses of 30 db or better are acceptable. The open/short value can be used as a guide to whether return loss is getting out of hand, but the correlation is not perfect. Figure 4 shows the measured return loss of the Three-Bead-Balun Bridge, using a technique described later. This technique does not pin down the exact return loss, but does indicate the worst that the return loss can be. In the case of Figure 4, the technique could only be used up to 300 MHz:

Figure 4 Return Loss of DUT Port to 300 MHz Figure 4 shows that the return loss is extremely good from 250 KHz to 300 MHz. Given the open/short and directivity values, I would expect this good return loss to continue beyond 1 GHz, possibly dipping below 30 db briefly around 450 MHz. Measuring Return Loss Manually A reflection bridge can be used to measure return loss manually, as described above under Operation. The question arises as to how accurate such measurements are, given the lack of OSL calibration, which a VNA would perform. First, consider how much accuracy is needed. Return loss indicates the amount of power reflected by the DUT. Generally, if the DUT has return loss of 30 db or better (higher), it is reflecting so little power that it does not really matter exactly how little it is. Or in terms of impedance, return loss of 30 db or better means the impedance of the DUT is close enough to 50 ohms that it can be considered to be 50 ohms. For example, resistances between 47 and 53 ohms have return losses of 30 db or higher. On the other hand, if a DUT reflects half or more of the power reaching it, we may just consider it to be unacceptable, without having to know exactly how much it reflects. A DUT with a return loss of 3 db or worse (lower) reflects at least half the power reaching it. So if we know the return loss is higher than 30 db or lower than 3 db, that may be all we need to know. And even for values in the 3-30 db range, errors of several db may not be meaningful. The one situation where precision might be useful is to determine the exact impedance of the DUT, for example in order to devise an impedance matching network to adjust it to 50 ohms. However, because return loss is a scalar value, we cannot determine the exact impedance even if

we knew the exact return loss. Phase information would be required. Our manual use of the bridge provides only scalar information, and is effectively a scalar network analyzer, as opposed to the fancier vector network analyzers, which provide phase information. The absence of phase information in return loss generally makes it pointless to try to determine return loss precisely. With that background, what error can we actually expect? Consider the frequency range 1 MHz to 1 GHz. Directivity in that range equals or exceeds 30 db, so assume as the worst case that it equals 30 db for the entire range. Return loss of the DUT port exceeds 30 db at least up to 300 MHz, and we have reason to expect it will do so up to 1 GHz, possibly with a small dip below 30 db near 450 MHz. With those numbers, the major sources of error are as twofold. First, the open/short discrepancy creates some error. Ideally, we would use the bridge output with an open DUT as the reference to calculate return losses for large resistances, and the output with a shorted DUT to calculate return losses for small resistances. But we don t know what resistance we are measuring, so we use the average of the open and short values. That creates a possible error equal to half the open/short difference. In our case, this difference reaches a maximum of 0.7 db, so the error is 0.35 db. It is conceivable that the calculation for reactive devices might involve larger error; we don t have phase information so we can t be precise about that. But our open/short and directivity levels are so good and well behaved that I would not expect there to be additional error for reactive devices. But let s say the total error from the open/short discrepancy may equal 0.5 db. Second, directivity essentially indicates a bogus reflection that is present even when there is no real reflection from the DUT. If the DUT actually produces a reflection, the bogus reflection may add to or subtract from that reflection, depending on phasing. So the bogus reflection may cause us to measure too much or too little reflection. With our assumed directivity of 30 db, we can actually calculate the extent of maximum error in our measurement. I won t describe the process here, but Figure 5 illustrates the relationship between our return loss reading and the possible range of values of the actual return loss.

Figure 5 Possible actual return loss values for a given return loss reading. For example, a reading of 20 db indicates the true return loss lies above 17 db and below 23 db. Figure 5 shows that we can determine return losses with reasonable accuracy if they are below 20 db. Once the return loss reading rises to 30 db and higher, we can say with confidence that the return loss is at least some minimum value (24 db for a reading of 30 db), but there is no limit to what the maximum might be. That may seem like unacceptable error, but remember that for large return losses we frequently only need to know that the return loss exceeds some threshold, without caring how far it exceeds the threshold. If we get a very large reading, like 60 db, we can be sure the true return loss is at least 30 db, which may be all we are looking for. Remember our 0.5 db uncertainty resulting from the open/loss discrepancy. For readings above 15 db, that error is dwarfed by the uncertainty created by directivity. For readings near zero, it becomes significant. For very low readings, indicating highly reflective DUTs, there are additional possibilities for error. It is probably good practice to proceed as follows: 1. For readings below 5 db, assume a 1 db error. 2. For readings of 5 db to 25 db, use the graph in Figure 5 to estimate the possible error, and add 0.5 db.

3. For readings above 25 db, use the graph in Figure 5 to estimate the minimum possible return loss, and assume there is no ceiling to how high the true return loss may be. The graph in Figure 4 was actually calculated by the method described in (3), using a bridge whose directivity was greater than 60 db at low frequencies and dropped to 40 db at 300 MHz. That is an active bridge using op amps, and will be described in a separate paper.

APPENDIX--Schematic