Agilent 8757D Scalar Network Analyzer 10 MHz to 110 GHz
|
|
|
- Jonas O’Neal’
- 10 years ago
- Views:
Transcription
1 Agilent 8757D Scalar Network Analyzer 10 MHz to 110 GHz Data Sheet Accurate measurement of transmission and reflection characteristics is a key requirement in your selection of a scalar network analyzer. To help you achieve these goals, Agilent Technologies offers you a choice of microwave scalar measurement solutions which provide an excellent balance of cost, system versatility, and measurement precision. Agilent 8757D overview of features Four display channels Three detector inputs An optional fourth detector input An optional internal power calibrator Accurate power measurements with Agilent series precision detectors High resolution color display Internal plotter/printer buffer +16 to 60 dbm dynamic range AC/DC detection modes 101 to 1601 measurement points/trace Noise figure measurement display capability Compatible with the Agilent and series detectors and the Agilent series directional bridges Limit line testing (channels 1 and 2) Adaptive normalization Cursor search functions (max, min, n db, BW) Specifications describe the instrument s warranted performance over the temperature range 0 to 55 C (except where noted). Supplemental characteristics are intended to provide information useful in applying the instrument, by giving typical but non-warranted performance parameters. These are denoted as typical, nominal, or approximate.
2 Agilent 8757D scalar network analyzer The Agilent 8757D has four independent display channels that process the signals from the Agilent series precision detectors, and detectors, and the series directional bridges for logarithmic display, in single channel or ratio mode. Three (optionally four) detector inputs are provided. Display Horizontal resolution The number of points (horizontal resolution) that can be selected depends on the number of traces displayed. Network analyzer Traces Selectable number of points 8757D 1 101, 201, 401, 801, , 201, 401, 801 3, 4 101, 201, 401 Display modes All analyzer display channels can display any one of the detector inputs or any ratio combination of detector inputs. Log magnitude dbm: single channel power measurement db: relative power measurement (ratio or relative to trace memory) SWR Relative measurements (normalized or ratio measurements) can be displayed in SWR. Channels 1 and 2 only: 401 points or fewer AUX voltage The rear panel BNC input ADC IN can be measured and displayed in volts ( 10 to +10 volts). Typical maximum error is 60 mv. Sweep time The minimum sweep time depends on the number of traces displayed and the number of points selected. Minimum sweep time (ms) Number (log magnitude format) of points 1 trace 2 traces 3 traces 4 traces NA NA NA NA NA Averaging 2, 4, 8, 16, 32, 64, 128, or 256 successive traces can be averaged. Smoothing Provides a linear moving average of adjacent data points. The smoothing aperture defines the trace width (number of data points) to be averaged, and ranges from 0.1% to 20% of the trace width. Normalization Traces are stored and normalized with the highest resolution, independent of display scale/division or offset. With adaptive normalization on the Agilent 8757D, calibration data is interpolated when the frequency span is decreased. Limit lines Limit lines facilitate quick pass/fail decisions. Limits can be any combination of flat or sloped lines or single points up to 12 segments. They are only available for channels 1 and 2, for traces with 401 points or fewer, and can be stored in save/recall registers 1 through 4. Color settings Up to 8 operator-selectable colors are available for LCD attributes, such as the grid, measurement traces, and labels. 2
3 Internal save/recall registers Up to 9 complete front panel states may be saved or recalled. If the source (Agilent PSG, 8360 or 8370 series) is connected to the 8757 system interface, the front panel states of both the network analyzer and source are saved. Registers 1 through 4 store the instrument state and the memory traces for channels 1 and 2. The memory traces for channels 3 and 4 are not stored. Registers 5 through 9 only store the instrument state. Display Scale Display Vertical mode resolution range resolution dbm 0.1 to 20 db/div 80 to +80 dbm db 1 (1/2/5 sequence) db 0.1 to 20 db/div 90 to +90 db db 1 (1/2/5 sequence) Normalized 0.1 to 20 db/div 180 to +180 db 0.01 db ratio (1/2/5 sequence) measurements Modulator drive The modulator drive output of the 8757 scalar analyzer provides the circuitry to drive the 8340/50/60/70 series synthesized sweepers and the Agilent 11665B modulator. Modulation drive may be turned on and off via the front panel or GPIB. In the off state, the modulator drive signal turns the 11665B fully on for minimum insertion loss. The 8360 and 8370 synthesized sweepers have the capability of modulating signals, so an external modulator such as the 11665B is not necessary when using the 8360/70 series. Frequency: 27,778 Hz ±12 Hz Symmetry: 50% ±1% Stop sweep Used with the PSG, 8360 and 8370 series when controlled by the 8757 system interface to stop the sweep at band crossings and at the end of sweep. SWR 0.02 to 10 units/div 1.0 to at 1 (1/2/4 sequence) 0.1 at at 30 AUX to 5 V/div 10 to +10 V V voltage (1/2.5/5 sequence) db for display cursor Modulation requirements Applies to the Agilent series precision detectors, 85025/26 series detectors, and series directional bridges in AC mode. Square-wave amplitude modulation Frequency 27,778 Hz ±20 Hz 30 db on/off ratio 45% to 55% symmetry Rear panel connectors Sweep voltage requirements (Sweep in) Horizontal sweep voltage, normally provided by the sweeper, from 0 to 10 volts. Marker and blanking requirements (Pos z blank) Blanking and marker signals are provided by the sweeper through the Pos z blank input on the rear panel of the Agilent Voltage levels Blanked: +5 V typical Unblanked: 0 V typical Marker: 4 V typical Active marker: 8 V typical ADC in An input connector for auxiliary voltage input in the 10 to +10 volt range. This voltage can be displayed (in volts) on any channel. Control 1 and control 2 These connectors provide digital output signals (TTL open-collector) as a user convenience for driving other peripheral equipment in a GPIB controlled system. Video outputs Used to drive an external color monitor that has the following characteristics: 8757D with LCD monitor (VGA input on the analyzer s rear panel) VGA compatible 8757D with CRT monitor (RGB inputs on the analyzer s rear panel) Red, green, and blue (RGB) BNC inputs, sync on green 75 ohm input impedance 26.5 khz horizontal scan rate 60 Hz vertical refresh rate 1 V p-p (typically 0.7 V = white; 0 V = black; -0.3 V = sync) 3
4 Agilent 8757D scalar network analyzer, continued GPIB Interface GPIB operates according to IEEE and IEC-625 interface standards. Interface function codes SH1, AH1, T6, TE0, L4, LE0, SR1, RL1, PP0, DC1, DT0, C0, E1. Transfer formats Data can be transferred either as ASCII strings or as 16-bit integers. Readings may be taken at a single point, or an entire trace may be transferred at once. Transfer speed ASCII format, 401 point trace: ASCII format, single point: Binary format, 401 point trace: Binary format, single point: ms typical 10 ms typical 30 ms typical 7 ms typical Programmable functions All front panel functions except power on/off are programmable. The 8757D is compatible with all appropriate 8757A/C scalar analyzer programming codes. User-accessible display graphics HPGL subset that allows user to display test setup diagrams and operator instructions on the analyzer CRT/LCD. Interrupts GPIB service interrupts (SRQs) are generated for the following conditions: Front-panel key pressed Operation complete Illegal command Instrument self-test error Limit test failed 1 URL location: System interface The Agilent 8757 system interface is a dedicated GPIB port used exclusively by the 8757 to control and extract information from a swept source, a digital plotter, and a printer. Compatible swept sources The following swept sources are specifically made to complement the 8757 system. With them, the 8757 is able to display start, stop, and marker frequencies, save and recall front panel states of both the sweeper and the scalar analyzer, preset both instruments simultaneously, and alternately sweep two different frequency or power ranges and display both simultaneously: Agilent PSG 1 signal generators (Option 007) Agilent 8360 series synthesized sweeper Agilent 8370 series synthesized sweeper Printers For a list of compatible printers, consult our printer-compatibility guide Web page. Its URL location is Or go to and use keyword search printer guide. Internal plotter/printer buffer The GPIB buffer speeds measurements by returning the control to the analyzer while outputting data to a plotter or printer. Output two channels (401 points each) of information to the buffer in typically less than 5 seconds. Note: In order to use the currently available printers a GP-IB to parallel port adapter is needed. Adapters are available from Intelligent Interfaces. Please see their website at Disk interface The 8757D provides the capability to store and retrieve the analyzer s instrument state, measurement data, and user accessible display graphics to and from an external GPIB disk drive that is compatible with command subset CS/80. Data files are stored in Agilent s standard LIF format and can be read by a wide variety of computers, including the HP 9000 series 200 or 300. Files can be stored in binary or ASCII format. Disk Drive Agilent no longer offers Option 802, the HP 9122C disk drive. Agilent 8757D-compatible disk drives are available from ISA, Inc. In the U.S., contact Saaya, Inc. (formerly known as ISA, Inc.). Elsewhere, contact ISA Company, Ltd. at
5 General information Temperature range Operating: 0 to 55 C Storage: 40 to 75 C Power requirements 48 to 66 Hz, 100/120/220/240 V ±10%, typically 155 VA Ordering information Agilent 8757D scalar network analyzer (select one) 8757D-700 Standard network analyzer 8757D-001 Adds fourth detector input 8757D-002 Adds internal power calibrator 8757D-012 Adds fourth detector and internal calibrator Dimensions: 178 H x 425 W x 482 mm D (7.0 x x 19.0 in) Weight: Net 22 kg (48 lb), Shipping: 28 kg (61.5 lb) Power calibrator (Option 002 only) The 8757D s internal power calibrator provides a 50 MHz reference standard for characterizing the absolute power accuracy and dynamic power accuracy of the series precision detectors. Frequency: 50 MHz ±0.2 MHz Output power: (25 ±5 C) Range: +20 to 50 dbm Accuracy at 0 dbm: ±0.05 db Linearity: (over any 10 db range) ±0.08 db (+20 to +10 dbm) ±0.04 db (+10 to 30 dbm) ±0.06 db ( 30 to 50 dbm) SWR: 1.05 Modes of operation DC Mode (unmodulated) AC Mode (modulated at 27,778 Hz ±12 Hz) Connector: Type-N (f) Accessory included A Type-N (m) to 3.5-mm (f) adapter is provided to allow calibration of the 85037B (3.5 mm) precision detector. 5
6 System accuracy Transmission measurement accuracy Transmission loss or gain measurements are made relative to a 0 db reference point established at calibration. Transmission measurement uncertainty = dynamic power accuracy + mismatch uncertainty Dynamic power accuracy is the measurement uncertainty due to the change in power level between calibration and the measurement. Mismatch uncertainty is the uncertainty due to reflections in the measurement setup. The frequency response errors of the source, detectors, bridge, and power splitter are removed via calibration. Transmission measurement uncertainty examples Assumptions: Measurement frequency = 10 GHz DUT input/output SWR = 1.5 Ratio measurement Change in power after calibration <30 db (+0 to 30 dbm range) Absolute power measurement accuracy This specification is useful for determining the accuracy of power measurements in dbm when using the Agilent series precision detectors or the series detectors in DC mode. Absolute power uncertainty = absolute power accuracy at 50 MHz + frequency response + mismatch uncertainty Absolute power measurement uncertainty examples Assumptions: Measurement frequency = 10 GHz DUT input/output SWR = 1.5 Power = +10 dbm 85037B 85025E Uncertainty component precision detector detector Absolute power accuracy at 50 MHz (±db) Frequency response (±db) Mismatch (±db) Total (±db) B 85025E Uncertainty component precision detector detector Dynamic accuracy (±db) Mismatch (±db) Total (±db) Change in power after calibration 60 db (+6 to 55 dbm range) 85037B 85025E Uncertainty component precision detector detector Dynamic accuracy (±db) Mismatch (±db) Total (±db) Power = 0 dbm 85037B 85025E Uncertainty component precision detector detector Absolute power accuracy at 50 MHz (±db) Frequency response (±db) Mismatch (±db) Total (±db) Power = 50 dbm 85037B 85025E Uncertainty component precision detector detector Absolute power accuracy at 50 MHz (±db) Frequency response (±db) Mismatch (±db) Total (±db)
7 Precision detector vs. power sensor absolute power measurement accuracy Accuracy terms differ depending on the test equipment used to make absolute power measurements. The following table simplifies and compares the accuracy terms of an Agilent 8757 system (using an series precision detector) and a power meter (using a power sensor). A measurement accuracy example is also provided. Scalar terms Equivalent power meter/sensor terms Reflection measurement accuracy Uncertainties due to calibration error and the frequency response of the source, detectors, and bridges are removed via open/short averaging. The remaining uncertainties are primarily the sum of directivity uncertainty, effective source match uncertainty, and dynamic power accuracy. As shown in the graphs below, directivity is the dominant error term when measuring small reflected signals (high return loss) and source match is dominant when measuring large reflected signals (low return loss). Absolute power accuracy at 50 MHz Frequency response Mismatch Power reference uncertainty Instrument linearity Zero set Noise Sensor calibration factor uncertainty Mismatch Effective source match vs. reflection uncertainty Scalar analyzer vs. power meter Absolute power measurement uncertainty examples Assumptions: Measurement frequency = 10 GHz DUT input/output SWR = 1.5 Power measurement range = +10 to 20 dbm Directivity vs. reflection uncertainty Uncertainty component (see above table for 8757D Opt. 002/ EPM-4418B equivalent power meter terms) 85037B 8485A Absolute power accuracy at 50 MHz (±db) Frequency response (±db) Mismatch (±db) Total (±db) Example calculation The following example shows how to find the uncertainty (excluding dynamic accuracy) in measuring a 14-dB return loss (SWR = 1.5) with an 85027A directional bridge at 10 GHz (directivity = 40 db, test port match = 1.25 SWR). Uncertainty component Source match error Directivity error Total uncertainty Uncertainty approximately ±0.2 db approximately ±0.4 db approximately ±0.6 db 7
8 System accessories Detectors Agilent series precision detectors (AC/DC) The series precision detectors are designed specifically for operation with the Agilent 8757D scalar network analyzer and are not compatible with the 8757A/E, 8756, or 8755 scalar network analyzers. These detectors may be used in either AC or DC detection modes. For improved power measurement accuracy versus frequency, each series precision detector includes detector specific frequency response data, stored in an internal EEPROM, which is automatically read by the 8757D. When used in conjunction with the 8757D s internal power calibrator (Option 002), these detectors provide the maximum absolute power measurement accuracy. Precision Detector Summary, Agilent Series 1 For use with the 8757D in either AC or DC detection modes Agilent and series detectors (AC/DC) The and series detectors are designed specifically for operation with the Agilent 8757 scalar network analyzer and are not compatible with either the 8756 or the The 85025/26 detectors may be used in either AC or DC detection modes. General information coaxial detectors Impedance: 50 ohms nominal Maximum input power: +20 dbm (100 mw) Maximum input voltage: 10 VDC Dimensions: Cable length is 1.22 m (48 in.) Weight: Net 0.24 kg (0.5 lb), Shipping 1.0 kg (2.2 lb) Detector adapters The Agilent 85025C detector adapters match the scalar analyzer display to most standard crystal, silicon, and gallium arsenide detectors. This enables the user to operate up to 110 GHz with the Agilent The 85025C detector adapters are designed for use with the 8757 only, and can operate in either AC or DC detection modes. Maximum measurable input: ±3 V peak Maximum allowable input: ±10 V peak Connector: SMA (m) Frequency Connector Return Frequency Model range type Dynamic range Frequency loss response A 10 MHz to 18 GHz Type-N (m) AC mode +20 to 55 dbm 0.01 to 0.04 GHz 10 db ±0.35 db 7 mm 2 DC mode +20 to 50 dbm 0.04 to 18 GHz 20 db ±0.18 db 85037B 10 MHz to 26.5 GHz 3.5 mm (m) AC mode +20 to 55 dbm 0.01 to 0.04 GHz 10 db ±0.35 db DC mode +20 to 50 dbm 0.04 to 18 GHz 20 db ±0.18 db 18 to 26.5 GHz 18 db ±0.22 db Power Dynamic accuracy 4,5 Absolute accuracy 4,6 Model (50 MHz) Corrected Default Corrected Default 85037A/B 20 dbm ±0.25 db ±0.40 db ±0.25 db ±0.40 db 10 dbm ±0.11 db ±0.40 db ±0.11 db ±0.40 db 30 dbm ±0.11 db ±0.40 db ±0.11 db ±0.40 db 40 dbm ±0.40 db ±0.80 db ±0.40 db ±0.80 db 50 dbm ±0.85 db ±1.30 db ±0.85 db ±1.30 db 55 d8m ±0.85 db ±1.30 db Temperature coefficient of linearity: 0.01 db/ C temperature change after calibration 1. The 85037A/B specifications are only applicable when used with the 8757D scalar network analyzer. 2. Option 001 changes to 7 mm connector dbm, 25 ±5 C 8 4. The corrected specifications apply after a calibration via the 8757D-002 internal power calibrator. The default specifications apply when the calibrator is not used. Power calibrator uncertainty is included in the 85037A/B corrected specifications. 5. Dynamic accuracy refers to measurement accuracy as power varies (in db) from a 0 dbm reference. 25 ±5 C. 50 MHz, calibration and measurement at the same temperature. 6. DC mode. 25 ±5 C, calibration and measurement at the same temperature.
9 Coaxial Detector Summary, Agilent Series For use with the 8757 in either AC or DC detection modes Frequency Connector Dynamic Return Frequency Power Dynamic Absolute Model range type range Frequency loss response 2 (50 MHz) accuracy 3 accuracy A 5 10 MHz to Type-N (m) AC mode 0.01 to 0.04 GHz 10 db ±0.8 db 16 dbm ±0.8 db ±0.8 db 18 GHz +16 to 55 dbm 0.04 to 4 GHz 20 db ±0.5 db 6 dbm ±0.4 db ±0.4 db 7 mm 1 DC mode 4 to 18 GHz 17 db ±0.5 db 35 dbm ±0.4 db ±0.4 db +16 to 50 dbm 50 dbm ±1.3 db ±1.3 db 55 dbm ±1.6 db 85025B 5 10 MHz to 3.5 mm (m) AC mode 0.01 to 0.04 GHz 10 db ±0.8 db 16 dbm ±0.8 db ±0.8 db 26.5 GHz +16 to 55 dbm 0.04 to 4 GHz 20 db ±0.5 db 6 dbm ±0.4 db ±0.4 db DC mode 4 to 18 GHz 17 db ±0.5 db 35 dbm ±0.4 db ±0.4 db +16 to 50 dbm 18 to 26.5 GHz 12 db ±2.0 db 50 dbm ±1.3 db ±1.3 db 55 dbm ±1.6 db 85025D 5 10 MHz to 2.4 mm (m) AC mode 0.01 to 0.1 GHz 10 db ±0.8 db 16 dbm ±1.0 db ±1.0 db 50 GHz +16 to 55 dbm 0.1 to 20 GHz 20 db ±0.5 db 6 dbm ±0.4 db ±0.4 db DC mode 20 to 26.5 GHz 20 db ±1.0 db 35 dbm ±0.4 db ±0.4 db +16 to 50 dbm 26.5 to 40 GHz 15 db ±2.5 db 50 dbm ±1.3 db ±1.3 db 40 to 50 GHz 9 db ±3.0 db 55 dbm ±1.6 db 85025E 5 10 MHz to 3.5 mm (m) AC mode 0.01 to 0.1 GHz 10 db ±0.8 db 16 dbm ±1.0 db ±1.0 db 26.5 GHz +16 to 55 dbm 0.1 to 18 GHz 25 db ±0.5 db 6 dbm ±0.4 db ±0.4 db DC mode 18 to 25 GHz 25 db ±0.5 db 35 dbm ±0.4 db ±0.4 db +16 to 50 dbm 25 to 26.5 GHz 23 db ±1.4 db 50 dbm ±1.3 db ±1.3 db 55 dbm ±1.6 db Waveguide Detectors and Detector Adapters Summary For use with the 8757 only in either AC or DC detection modes Frequency Connector Return Frequency Dynamic Model range type Dynamic range loss response accuracy R85026A to WR to 50 dbm (AC mode) 12 db ±1.5 db ±(0.3 db db/db) 40 GHz +10 to 45 dbm (DC mode) Q85026A 5 33 to WR to 50 dbm (AC mode) 12 db ±2.0 db ±(0.3 db db/db) 50 GHz +10 to 45 dbm (DC mode) U85026A 5 40 to WR to 50 dbm (AC mode) 12 db ±2.0 db ± (0.3 db db/db) 60 GHz +10 to 45 dbm (DC mode) 85025CK-K to WR to 45 dbm (typical) 9.5 db 75 GHz (typical) 85025CK-K to WR to 45 dbm (typical) 9.5 db 110 GHz (typical) 85025C 5 6 SMA (m) Option 001 changes to 7 mm connector dbm, 25 ±5 C 3. Dynamic accuracy refers to measurement accuracy as power varies (in db) from a 0 dbm reference. 25 ±5 C, 50 MHz. 4. DC mode, 25 ±5 C. 5. The and series detectors and the 85025C detector adapter require 8757A firmware revision 2.0 or higher. 6. Depends on the detector. 7. Must be used with the 85025C detector adapter. 9
10 System accessories, continued Directional bridges Agilent series directional bridges (AC/DC) The series directional bridges are designed to operate with either the 8757 in AC or DC detection modes or with the 8756 or 8755 in AC detection mode. These bridges offer high directivity, excellent test port match, and a measurement range of up to 50 GHz in coax. General information directional bridges Dynamic power accuracy (50 MHz, 25 ±5 C, +7 dbm input) Typical insertion loss 6.5 db at 10.0 MHz 8.0 db at 18.0 GHz 10.0 db at 26.5 GHz 11.0 db at 40.0 GHz 13.0 db at 50.0 GHz Typical minimum input power for a 40 db return loss measurement at 18 GHz: +2 dbm Dimensions: 26 H x 124 W x 118 mm D (1.0 x 4.9 x 4.4 in) Weight: Net 0.5 kg (1.2 lb), Shipping 2.3 kg (5 lb) Accessories included with directional bridges: 85027A 7 mm open/short Type-N (m) (m) adapter 85027B 3.5 mm (m) open/short 3.5 mm (m) (m) adapter 3.5 mm (m) (f) adapter 85027C Type-N (m) short Type-N (m) shielded open Type-N (m) (m) adapter 85027D 2.4 mm (f) open 2.4 mm (f) short 85027E 3.5 mm (f) open/short 3.5 mm (f) (f) adapter 3.5 mm (f) (m) adapter Directional Bridge Summary For use with the 8757 in AC or DC detection mode or with the 8756 or 8755 in AC detection mode only Frequency Nominal Input Test port Test port Model range impedance connector connector Frequency Directivity Frequency match 85027A 10 MHz to 50 ohms Type-N (f) 7 mm 0.01 to 18 GHz 40 db 0.01 to 8.4 GHz <1.15 SWR 18 GHz 8.4 to 12.4 GHz <1.25 SWR 12.4 to 18 GHz <1.43 SWR 85027B 10 MHz to 50 ohms 3.5 mm (f) 3.5 mm (f) 0.01 to 20 GHz 40 db 0.01 to 8.4 GHz <1.15 SWR 26.5 GHz 20 to 26.5 GHz 36 db 8.4 to 20 GHz <1.43 SWR 20 to 26.5 GHz <1.78 SWR 85027C 10 MHz to 50 ohms Type-N (f) Type-N (f) 0.01 to 12.4 GHz 36 db 0.01 to 8.4 GHz <1.15 SWR 18 GHz 12.4 to 18 GHz 34 db 8.4 to 12.4 GHz <1.25 SWR 12.4 to 18 GHz <1.43 SWR 85027D 10 MHz to 50 ohms 2.4 mm (f) 2.4 mm (m) 0.01 to 26.5 GHz 35 db 0.01 to 16 GHz <1.18 SWR 50 GHz 16 to 30 GHz <1.27 SWR 26.5 to 40 GHz 30 db 30 to 40 GHz <1.40 SWR 40 to 50 GHz 25 db 40 to 50 GHz (typical) <1.85 SWR 85027E 10 MHz to 50 ohms 3.5 mm (f) 3.5 mm (m) 0.01 to 20 GHz 40 db 0.01 to 8.4 GHz <1.15 SWR 26.5 GHz 20 to 26.5 GHz 36 db 8.4 to 20 GHz <1.43 SWR 20 to 26.5 GHz <1.78 SWR 10
11 Power splitters The Agilent series power splitters are tworesistor splitters recommended for external source leveling or for ratio measurement applications. Power dividers The Agilent series power dividers are threeresistor splitters intended for direct power dividing applications such as transmission line fault location. The series can also be used as a power combiner. General information Impedance: 50 ohms nominal Dimensions: 42 H x 45 W x 18 mm D (1.6 x 1.8 x 0.7 in) Weight: Net 0.14 kg (0.3 lb), Shipping 0.45 kg (1.0 lb) General information Impedance: 50 ohms nominal Maximum input power: +27 dbm Dimensions: 46 H x 52 W x 21 mm D (1.8 x 2.0 x 0.8 in) Weight: Net 0.14 kg (0.3 lb), Shipping 0.22 kg (0.5 lb) Power splitters Frequency Input Output Insertion loss Equivalent Output Model range connector connectors Frequency (typical) output match tracking 11667A DC to 18 GHz Type-N (f) 1 Type-N (f) DC to 4 GHz 6.6 db 1.10 SWR 0.15 db 4 to 8 GHz 7.0 db 1.20 SWR 0.20 db 8 to 18 GHz 7.8 db 1.33 SWR 0.25 db 11667B DC to 26.5 GHz 3.5 mm (f) 3.5 mm (f) DC to 8 GHz 6.5 db 1.22 SWR 0.25 db 8 to 18 GHz 7.0 db 1.22 SWR 0.25 db 18 to 26.5 GHz 7.3 db 1.22 SWR 0.40 db 11667C DC to 50 GHZ 2.4 mm (f) 2.4 mm (f) DC to 18 GHz 6.0 db 1.29 SWR 0.30 db 18 to 26.5 GHz 7.0 db 1.20 SWR 0.35 db 26.5 to 40 GHz 8.0 db 1.50 SWR 0.40 db 40 to 50 GHz 8.5 db 1.65 SWR (typical) 0.40 db Power dividers Frequency Input Output Output Output Model range connector connectors Frequency match tracking 11636A DC to 18 GHz Type-N (m) Type-N (f) DC to 4 GHz 1.25 SWR 0.20 db 4 to 10 GHz 1.25 SWR 0.40 db 10 to 18 GHz 1.35 SWR 0.50 db 11636B DC to 26.5 GHz 3.5 mm (f) 3.5 mm (f) DC to 10 GHz 1.22 SWR 0.25 db 10 to 18 GHz 1.29 SWR 0.50 db 18 to 26.5 GHz 1.29 SWR 0.50 db 1. Option 001 changes the input connector to Type-N (m). 11
12 System accessories, continued Agilent 11679A/B extension cables These cables extend the distance between the scalar network analyzer and the detector or bridge to a maximum of 200 feet without degradation of performance A 7.6 m (25 ft) extension cable 11679B 61 m (200 ft) extension cable Agilent 11665B modulator Note: This product is no longer available. The 11665B modulator is only necessary when using the 8340/8341 series synthesizer. The 11665B modulates test signals with the 27.8 khz modulation drive signal from the scalar network analyzer. Frequency range: 15 MHz to 18 GHz Insertion loss and return loss Insertion loss Frequency Return loss ON (+50 ma) OFF ( 50 ma) 15 MHz to 40 MHz >10 db <7.0 db >35 db 40 MHz to 4 GHz >15 db <3.2 db >35 db 4 GHz to 8 GHz >12 db <3.8 db >40 db 8 GHz to 12.4 GHz >8 db <4.3 db >45 db 12.4 GHz to 18 GHz >8 db <5.0 db >45 db Maximum input: +24 dbm Connectors: Input: Type-N (f), Output: Type-N (m) Weight: Net: 0.17 kg (0.38 lbs), Shipping: 0.9 kg (2 lbs) Agilent 85022A system cable kit The 85022A contains the BNC and GPIB cables needed to connect a source to the Contents GPIB cable, 100 cm (3.3 ft.), 3 each 50 ohm BNC (m) cable, 61 cm (2 ft.), 3 each 50 ohm BNC (m) cable, 122 cm (4 ft.) Weight: Net: 0.5 kg (1.2 lbs.), Shipping: 1.2 kg (2.9 lbs) Agilent 11613B calibrator The 11613B is a dedicated transfer standard for calibration of the The 11613B provides the standard, a khz source, and a series of precision attenuators. The calibrator includes software (3.5-inch format) that operates on an HP 9000 series 200 or 300 computer, the BASIC operating system (BASIC 3.0 or higher), or an external controller with HP BASIC for Windows 7.0 or higher. The software verifies (and adjusts if necessary) the internal calibration parameters stored in the nonvolatile memory of the All 8757 detector inputs can be calibrated in a matter of minutes. Recalibration of the 11613B is recommended every two years. Memory requirement: 0.5 Mbyte Outputs The 5-pin cable (1.22 m) mates with the detector inputs of the The lines in this cable transfer the squarewave signal to the 8757, provide power for the 11613B (from the 8757 supply), and program the 11613B s internal attenuators. Dimensions: 40 H x 185 W x 203 mm D (1.5 x 7.3 x 8.0 in) Cable length: 1.22 m (48 in) Weight: Net: 0.91 kg (2 lbs), Shipping: 2.3 kg (5 lbs) Software Amplifier test software Agilent part number This amplifier test software automates basic amplifier measurements of gain, gain compression, return loss, and standing wave ratio. The software is completely menu driven for simplicity and ease of use. A 3.5-inch format is provided. Software operates on an HP 9000 series 200 or 300 computer. 12
13 Literature guide Pub. number Agilent 8757D/E scalar network E analyzers, Brochure Agilent 8757D scalar network E analyzer, Configuration Guide Improving network analyzer E measurements of frequencytranslating devices, Application Note Network analyzer measurements: E filter and amplifier examples, Application Note Microwave component measure ments; amplifier measurements using the scalar network analyzer, Application Note Measuring voltage-controlled devices with the Agilent 8757A scalar network analyzer, Product Note Improving scalar network analysis EN using the PSG signal generator and the 8757D scalar network analyzer, Application Note Get the latest information on the products and applications you select. 13
14 Agilent Technologies Test and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Support is available for at least five years beyond the production life of the product. Two concepts underlie Agilent s overall support policy: Our Promise and Your Advantage. Our Promise Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you use Agilent equipment, we can verify that it works properly, help with product operation, and provide basic measurement assistance for the use of specified capabilities, at no extra cost upon request. Many self-help tools are available. Your Advantage Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and on-site education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products. Agilent T&M Software and Connectivity Agilent s Test and Measurement software and connectivity products, solutions and developer network allows you to take time out of connecting your instruments to your computer with tools based on PC standards, so you can focus on your tasks, not on your connections. Visit for more information. By internet, phone, or fax, get assistance with all your test and measurement needs. Phone or Fax United States: (tel) Canada: (tel) (fax) China: (tel) (fax) Europe: (tel) (31 20) (fax) (31 20) Japan: (tel) (81) (fax) (81) Korea: (tel) (82 2) (fax) (82 2) Latin America: (tel) (305) (fax) (305) Taiwan: (tel) (fax) Other Asia Pacific Countries: (tel) (65) (fax) (65) [email protected] Online assistance: Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc Printed in USA, December 3, E
Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz
Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar Network Analyzer combines a 90 db wide dynamic range with the accuracy and linearity
Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet
Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers Data Sheet Specifications Specifications are only valid for the stated operating frequency, and apply over 0 C to +55 C unless otherwise
Agilent E5100A Network Analyzer
Agilent E5100A Network Analyzer Data Sheet These specifications are the performance standards or limits against which the instrument is tested. When shipped from the factory, the E5100A meets the specifications
Agilent 8753ET/8753ES Network Analyzers
Agilent 8753ET/8753ES Network Analyzers 8753ET, 300 khz to 3 or 6 GHz 8753ES, 30 khz to 3 or 6 GHz Configuration Guide System configuration summary The following summary lists the main components required
Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview
Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview Reduce your cost of ownership by minimizing time to calibrate and
Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers
Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers N4690 Series, 2-port Microwave ECal 85090 Series, 2-port RF ECal N4430 Series, 4-port ECal Technical Overview Control ECal directly
Agilent Test Solutions for Multiport and Balanced Devices
Agilent Test Solutions for Multiport and Balanced Devices Duplexer test solutions 8753ES option H39/006 During design and final alignment of duplexers, it is often necessary to see both the transmit-antenna
Agilent 8510-13 Measuring Noninsertable Devices
Agilent 8510-13 Measuring Noninsertable Devices Product Note A new technique for measuring components using the 8510C Network Analyzer Introduction The majority of devices used in real-world microwave
Power Amplifier Gain Compression Measurements
Technical Brief Power Amplifier Gain Compression Measurements GPIB Private Bus Sweep Out Sweep In Pulse In AC Mod Out Blank/Marker Out Blanking In Overview The 1 db gain compression of an amplifier describes
Impedance 50 (75 connectors via adapters)
VECTOR NETWORK ANALYZER PLANAR TR1300/1 DATA SHEET Frequency range: 300 khz to 1.3 GHz Measured parameters: S11, S21 Dynamic range of transmission measurement magnitude: 130 db Measurement time per point:
Agilent 8720 Family Microwave Vector Network Analyzers
Agilent 8720 Family Microwave Vector Network Analyzers Product Overview High-Performance Solutions for Your Measurement Challenges Now more choices for solving your measurement challenges What's new in
2398 9 khz to 2.7 GHz Spectrum Analyzer
Spectrum Analyzers 2398 9 khz to 2.7 GHz Spectrum Analyzer A breakthrough in high performance spectrum analysis, combining cost effectiveness and portability in a new lightweight instrument 9 khz to 2.7
Agilent Technologies 3000 Series Oscilloscopes
Agilent Technologies 3000 Series Oscilloscopes Data Sheet The performance and features you need at the industry s lowest price Features: 60 to 200 MHz bandwidths 1 GSa/s maximum sample rate Large 15-cm
81110A Pulse Pattern Generator Simulating Distorted Signals for Tolerance Testing
81110A Pulse Pattern Generator Simulating Distorted Signals for Tolerance Testing Application Note Introduction Industry sectors including computer and components, aerospace defense and education all require
Agilent 4338B Milliohm Meter
Agilent 4338B Milliohm Meter 10 µω to 100 kω Technical Overview Introduction Ideal for precise measurements of extremely low resistances using an ac test signal, the Agilent Technologies 4338B suits bench-top
R&S ZNC Vector Network Analyzer Specifications
ZNC3_dat-sw_en_5214-5610-22_v0300_cover.indd 1 Data Sheet 03.00 Test & Measurement R&S ZNC Vector Network Analyzer Specifications 04.09.2012 13:39:47 CONTENTS Definitions... 3 Measurement range... 4 Measurement
Microwave. 6200B series RF and Microwave Test sets. www.aeroflex.com
Microwave 6200B series RF and Microwave Test sets With compliments Helmut Singer Elektronik www.helmut-singer.de [email protected] fon +49 241 155 315 fax +49 241 152 066 Feldchen 16-24 D-52070 Aachen
Agilent Creating Multi-tone Signals With the N7509A Waveform Generation Toolbox. Application Note
Agilent Creating Multi-tone Signals With the N7509A Waveform Generation Toolbox Application Note Introduction Of all the signal engines in the N7509A, the most complex is the multi-tone engine. This application
Agilent Technologies E8047B Analysis Probe System for the Intel Xeon Processor Family
Agilent Technologies E8047B Analysis Probe System for the Intel Xeon Processor Family Product Overview Requires an Agilent 16700A/B Series or 16900A Series Logic Analysis System The Agilent E8047B analysis
Agilent PN 8753-1 RF Component Measurements: Amplifier Measurements Using the Agilent 8753 Network Analyzer. Product Note
Agilent PN 8753-1 RF Component Measurements: Amplifier Measurements Using the Agilent 8753 Network Analyzer Product Note 2 3 4 4 4 4 6 7 8 8 10 10 11 12 12 12 13 15 15 Introduction Table of contents Introduction
Agilent 4339B/4349B High Resistance Meters
Agilent 4339B/4349B High Resistance Meters Technical Overview Within Budget Without Compromise Introducing the Agilent Technologies 4339B and 4349B High Resistance Meters Used for Making Ultra- High Resistance
Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy
Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy Application Note RF & Microwave Spectrum Analyzers Table of Contents 3 3 4 4 5 7 8 8 13 13 14 16 16 Introduction Absolute versus relative
R&S ZNBT8 Vector Network Analyzer Specifications
ZNBT8_dat-sw_en_3606-9727-22_v0200_cover.indd 1 Data Sheet 02.00 Test & Measurement R&S ZNBT8 Vector Network Analyzer Specifications 20.05.2014 08:39:42 CONTENTS Definitions... 3 Measurement range... 4
Agilent E4401B, E4402B, E4404B, E4405B, and E4407B ESA-E Series Spectrum Analyzers
Agilent, E4402B, E4404B, E4405B, and E4407B ESA-E Series Spectrum Analyzers Technical Specifications All specifications apply over 0 C to + 55 C unless otherwise noted. The analyzer will meet its specifications
Agilent PN 89400-13 Extending Vector Signal Analysis to 26.5 GHz with 20 MHz Information Bandwidth
Agilent PN 89400-13 Extending Vector Signal Analysis to 26.5 GHz with 20 MHz Information Bandwidth Product Note The Agilent Technologies 89400 series vector signal analyzers provide unmatched signal analysis
Performing Amplifier Measurements with the Vector Network Analyzer ZVB
Product: Vector Network Analyzer R&S ZVB Performing Amplifier Measurements with the Vector Network Analyzer ZVB Application Note This document describes typical measurements that are required to be made
R&S ZVA Vector Network Analyzer Specifications
www.atecorp.com 8-44-ATEC (2832) R&S ZVA Vector Network Analyzer Specifications ZVA_dat-sw_en_523-568-22_v_cover.indd Data Sheet. E stablished 98 Advanced Test Equipment Rentals Test & Measurement 4.5.22
One Port Network Analyzer
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com One Port Network Analyzer 5.4GHz Impendance : 50Ω(75Ωconnectors via adapters) Test
DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS
DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display
Agilent 8904A Multifunction Synthesizer dc to 600 khz
Agilent 8904A Multifunction Synthesizer dc to 600 khz Technical Specifications Build complex waveforms from common signals The Agilent Technologies 8904A Multifunction Synthesizer uses VLSIC technology
SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION
1 SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION By Lannes S. Purnell FLUKE CORPORATION 2 This paper shows how standard signal generators can be used as leveled sine wave sources for calibrating oscilloscopes.
Agilent Evolution of Test Automation Using the Built-In VBA with the ENA Series RF Network Analyzers
Agilent Evolution of Test Automation Using the Built-In VBA with the ENA Series RF Network Analyzers Product Note E5070/71-2 An easy-to-learn and easy-to-use programming language 1. Introduction The Agilent
CellAdvisor. JD725A Dual-Port Cable and Antenna Analyzer
CellAdvisor JD725A Dual-Port Cable and Antenna Analyzer Many modern wireless base stations are a complex system of multiple RF components, such as low-noise amplifiers (LNA), duplexers, and tower-mounted
Agilent U2000 Series USB Power Sensors
Agilent U2000 Series USB Power Sensors GSM Timeslot Burst Power Measurement Product Note Table of Content Introduction 2 Measuring GSM Timeslot 4 Signal Overview of Agilent U2000 5 Series USB Power Sensors
APSYN420A/B Specification 1.24. 0.65-20.0 GHz Low Phase Noise Synthesizer
APSYN420A/B Specification 1.24 0.65-20.0 GHz Low Phase Noise Synthesizer 1 Introduction The APSYN420 is a wideband low phase-noise synthesizer operating from 0.65 to 20 GHz. The nominal output power is
THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES
TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry
Agilent GSM/EDGE Base Station Test with the E4406A VSA and ESG-D Series RF Signal Generators Product Overview
Agilent GSM/EDGE Base Station Test with the E4406A VSA and ESG-D Series RF Signal Generators Product Overview The flexible GSM/EDGE base station test solution with a 3G future... Designed for manufacturing
Agilent 8762/3/4A,B,C Coaxial Switches
Agilent 8762/3/4A,B,C Coaxial Switches Technical Overview High performance switches for microwave and RF instrumentation and systems Agilent Technologies offers a ver satile line of multiport coaxial switches.
Agilent P940xA/C Solid State PIN Diode Switches
Agilent P940xA/C Solid State PIN Diode Switches Operating and Service Manual Agilent Technologies Notices Agilent Technologies, Inc. 2007 No part of this manual may be reproduced in any form or by any
FFT Spectrum Analyzers
FFT Spectrum Analyzers SR760 and SR770 100 khz single-channel FFT spectrum analyzers SR760 & SR770 FFT Spectrum Analyzers DC to 100 khz bandwidth 90 db dynamic range Low-distortion source (SR770) Harmonic,
Microwave Multiplexer Module
Microwave Multiplexer Module Form Drive s K90 OM K90 OM K90 OM Agilent 44476A Switching signals from D to 8 GHz Triple -to- microwave multiplexers N N N Drive Jumpers W W W HP876B HP876B HP876B L90 V TO
HP 70950B OPTICAL SPECTRUM ANALYZER
HP 71450B, 71451B, and 71452B Optical Spectrum Analyzers Technical Specifications Spectral Measurements from 600 to 1700 nm HP 70950B OPTICAL SPECTRUM ANALYZER OPTICAL INPUT The HP 71450B, 71451B, and
Agilent E4980A Precision LCR Meter 20 Hz to 2 MHz
Agilent E4980A Precision LCR Meter 20 Hz to 2 MHz Setting a new standard for low frequency impedance measurements Providing the best combination of accuracy, speed and versatility A New Standard for Impedance
2. The Vector Network Analyzer
ECE 584 Laboratory Experiments 2. The Vector Network Analyzer Introduction: In this experiment we will learn to use a Vector Network Analyzer to measure the magnitude and phase of reflection and transmission
HP 8753E RF Vector Network Analyzer
HP 8753E RF Vector Network Analyzer 30 khz to 3 or 6 GHz Fast and powerful, the HP 8753E is perfectly adapted for superior, efficient measurements 2 Impressive 300% speed improvement in measurement sweep,
Agilent E3830 Series Wide-bandwidth Signal Analyzer Custom Systems 100 MHz Bandwidth Microwave Vector Signal Analysis
Agilent E3830 Series Wide-bandwidth Signal Analyzer Custom Systems 100 MHz Bandwidth Microwave Vector Signal Analysis The measurement challenge 2 Many advanced microwave applications involve complex wideband
DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS
DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display
Analogue/Digital Analogue and Differential Oscilloscopes
Analogue/Digital Analogue and Differential Oscilloscopes Metrix oscilloscopes are designed to meet all your signal measurement and analysis needs, for production, laboratory, R&D or professional training
How To Use A High Definition Oscilloscope
PRELIMINARY High Definition Oscilloscopes HDO4000 and HDO6000 Key Features 12-bit ADC resolution, up to 15-bit with enhanced resolution 200 MHz, 350 MHz, 500 MHz, 1 GHz bandwidths Long Memory up to 250
FREQUENCY RESPONSE ANALYZERS
FREQUENCY RESPONSE ANALYZERS Dynamic Response Analyzers Servo analyzers When you need to stabilize feedback loops to measure hardware characteristics to measure system response BAFCO, INC. 717 Mearns Road
A Guide to Calibrating Your Spectrum Analyzer
A Guide to Calibrating Your Application Note Introduction As a technician or engineer who works with electronics, you rely on your spectrum analyzer to verify that the devices you design, manufacture,
MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card
Machinery Protection Card Type FEATURES Continuous on-line Machinery Protection Card Real-time measurement and monitoring using state-of-the-art DSP techniques Fully VME-compatible slave interface Fully
Cond-IS RF Conducted Immunity System
Cond-IS RF Conducted Immunity System About RF Conducted Immunity In the global contest of EMC testing for residential and industrial EUTs (Equipments Under Test) RF Conducted Immunity compliance verification
iva Cable & Antenna Analyzer
iva Cable & Antenna Analyzer VSWR, Return Loss Measurement & Distance to Fault The iva Series Cable & Antenna Analyzer is an exciting new product from Kaelus that enables users to accurately measure VSWR/return
Scalar Network Analysis with the HP 8590 Series Spectrum Analyzers Product Overview
This literature was published years prior to the establishment of Agilent Technologies as a company independent from Hewlett-Packard and describes products or services now available through Agilent. It
Description: Multiparameter System (4 or 8 channels)
Model MPA4, 8 ch acquisition system with 6 ns time tagging The MPA4 is a Multiparameter Data Acquisition System Description: Multiparameter System (4 or 8 channels) ADC Settings and Presets Dialog The
Network analyzer and spectrum analyzer two in one
R&S ZVL Vector Network Analyzer Network analyzer and spectrum analyzer two in one The R&S ZVL is the lightest and smallest vector network analyzer in its class. On top of this, it can be used as a full-featured
Agilent E363xA Series Programmable DC Power Supplies. Data Sheet
Agilent E363xA Series Programmable DC Power Supplies Data Sheet Reliable Power, Repeatable Results Single and triple output 80 W to 200 W output power Dual range output Low noise and excellent regulation
Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832)
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Agilent E5100A/B Network Analyzer 10 khz to 180 MHz/300 MHz Product Overview Agilent s fastest analyzer improves production
Multi-Range Programmable DC Power Supplies 9115 Series
Data Sheet 1200 W Multi-Range DC Power Supplies Features & Benefits Any 9115 series model can replace several supplies on your bench or in your rack. Unlike conventional supplies with fixed output ratings,
Scalar Network Analyzer
Scalar Network Analyzer Dave Collins AD7JT George Heron N2APB www.midnightdesignsolutions.com/nat Features Handheld SNA measures filters, crystals, antennas, and more Measurement capabilities provided
RF Network Analyzer Basics
RF Network Analyzer Basics A tutorial, information and overview about the basics of the RF Network Analyzer. What is a Network Analyzer and how to use them, to include the Scalar Network Analyzer (SNA),
LT-82 Stationary IR Transmitter
LT-82 Stationary IR Transmitter Configuration LT-82-0 (North America) LT-82-02 (Asia, UK) LT-82-03 (Euro) The Listen LT-82 is the heart of a stationary IR listening system. It takes the desired audio signal
MATRIX TECHNICAL NOTES
200 WOOD AVENUE, MIDDLESEX, NJ 08846 PHONE (732) 469-9510 FAX (732) 469-0418 MATRIX TECHNICAL NOTES MTN-107 TEST SETUP FOR THE MEASUREMENT OF X-MOD, CTB, AND CSO USING A MEAN SQUARE CIRCUIT AS A DETECTOR
HP 8753E RF Vector Network Analyzer. Technical Specifications. 30 khz to 3 GHz or 6 GHz. HP 8753E maximizes versatility and performance
HP 8753E RF Vector Network Analyzer Technical Specifications 30 khz to 3 GHz or 6 GHz The HP 8753E RF vector network analyzer provides all the performance and productivity features to simplify and speed
Waveform Monitor Audio & Loudness Logging
Waveform Monitor Audio & Loudness Logging PT0800M Data sheet Nov. 201 3 V.1.0 Introducing the PT0800M The PT0800 introduces a unique combination of Audio, Loudness and Waveform monitoring at the highest
Vector Network Analyzer Techniques to Measure WR340 Waveguide Windows
LS-296 Vector Network Analyzer Techniques to Measure WR340 Waveguide Windows T. L. Smith ASD / RF Group Advanced Photon Source Argonne National Laboratory June 26, 2002 Table of Contents 1) Introduction
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
Loop Bandwidth and Clock Data Recovery (CDR) in Oscilloscope Measurements. Application Note 1304-6
Loop Bandwidth and Clock Data Recovery (CDR) in Oscilloscope Measurements Application Note 1304-6 Abstract Time domain measurements are only as accurate as the trigger signal used to acquire them. Often
Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide
Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors Demo Guide Introduction This demonstration guide helps you to get familiar with the basic setup and coniguration requirements
DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
1.44 kw Programmable DC Power Supplies XLN Series
Data sheet 1.44 kw Programmable DC Power Supplies XLN Series New Family of High Density System Power Supplies The B&K Precision XLN series are compact, programmable, single-output DC power supplies, suitable
User s Guide. HP 8712ET and HP 8714ET RF Network Analyzers. HP Part No. 08714-90011. Printed in USA Print Date: October 1999
User s Guide HP 8712ET and HP 8714ET RF Network Analyzers HP Part No. 08714-90011 Printed in USA Print Date: October 1999 Supersedes: November 1998 Copyright 1998, 1999 Hewlett-Packard Company Notice The
Revision 1.10 April 7, 2015 Method of Implementation (MOI) for 100BASE-TX Ethernet Cable Tests Using Keysight E5071C ENA Option TDR
Revision 1.10 April 7, 2015 Method of Implementation (MOI) for 100BASE-TX Ethernet Cable Tests Using Keysight E5071C ENA Option TDR 1 Table of Contents 1. Revision History... 3 2. Purpose... 3 3. References...
1. The Slotted Line. ECE 584 Microwave Engineering Laboratory Experiments. Introduction:
ECE 584 Microwave Engineering Laboratory Experiments 1. The Slotted Line Introduction: In this experiment we will use a waveguide slotted line to study the basic behavior of standing waves and to measure
EE 186 LAB 2 FALL 2004. Network Analyzer Fundamentals and Two Tone Linearity
Network Analyzer Fundamentals and Two Tone Linearity Name: Name: Name: Objective: To become familiar with the basic operation of a network analyzer To use the network analyzer to characterize the in-band
Agilent U2000 Series USB Power Sensors
Agilent U2000 Series USB Power Sensors Configuration Guide U2000 Series USB Power Sensors U2000A (10 MHz to 18 GHz) U2001A (10 MHz to 6 GHz) U2002A (50 MHz to 24 GHz) U2004A (9 khz to 6 GHz) U2000H (10
Agilent 8510C Network Analyzer
8510C Agilent 8510C Network Analyzer Data Sheet 45 MHz to 110 GHz Contents Page System performance characteristics.........3 Major Agilent Technologies 8510 Network Analyzer Systems 8510E, Option 005,
HP 8970B Option 020. Service Manual Supplement
HP 8970B Option 020 Service Manual Supplement Service Manual Supplement HP 8970B Option 020 HP Part no. 08970-90115 Edition 1 May 1998 UNIX is a registered trademark of AT&T in the USA and other countries.
Agilent 8509C Lightwave Polarization Analyzer
Agilent 8509C Lightwave Polarization Analyzer Product Overview Highly accurate and repeatable polarization measurements of signal and components 1280 nm to 1640 nm L-Band extended wavelength option High
ECE 435 INTRODUCTION TO THE MICROWAVE NETWORK ANALYZER
ECE 435 INTRODUCTION TO THE MICROWAVE NETWORK ANALYZER Latest revision: October 1999 Introduction A vector network analyzer (VNA) is a device capable of measuring both the magnitude and phase of a sinusoidal
Multi-Range Programmable DC Power Supplies 9115 Series
Data Sheet Multi-Range Programmable DC Power Supplies 1200 W / 3000 W Multi-Range DC Power Supplies Features & Benefits Any model can replace several supplies on your bench or in your rack. Unlike conventional
Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics
Jeff Thomas Tom Holmes Terri Hightower Learn RF Spectrum Analysis Basics Learning Objectives Name the major measurement strengths of a swept-tuned spectrum analyzer Explain the importance of frequency
HP 8590 E-Series Portable Spectrum Analyzers Technical Specifications
HP 8590 E-Series Portable Spectrum Analyzers Technical Specifications Product Specifications and data These specifications apply to the, 8593E, 8594E, 8595E, and 8596E spectrum analyzers. Specifications
Experiment 7: Familiarization with the Network Analyzer
Experiment 7: Familiarization with the Network Analyzer Measurements to characterize networks at high frequencies (RF and microwave frequencies) are usually done in terms of scattering parameters (S parameters).
NEW PRODUCT ANNOUCEMENT
URRllEN TECHNOLOGY NEW PRODUCT ANNOUCEMENT ADS1000CL+ / CML DSO Series 25MHz ~ 200MHz We are glad to introduce to our global customers our new series of Digital Storage Oscilloscope under ADS1000 CL+ &
Agilent 8712ET/ES, 8714ET/ES RF Economy Network Analyzers Product Overview. Speed, accuracy, and productivity features, at a price you can afford
Agilent 8712ET/ES, 8714ET/ES RF Economy Network Analyzers Product Overview 8712ET and 8712ES, 300 khz to 1.3 GHz 8714ET and 8714ES, 300 khz to 3 GHz Speed, accuracy, and productivity features, at a price
1975-2004 GOOD WILL Instrument Co., Ltd. All rights reserved.
Introduction to 3GHz Spectrum Analyzer of Instek Front side Features Rear side 1Frequency Adjustment 2Ref. Input 3Ref. Out 4Ext. Trigger 5GPIB 6RS232 11 12 13 7USB 8VGA Output 9Ear Phone DC Input 11 Battery
E5092A Configurable Multiport Test Set
Keysight Technologies E5080A Network Analyzer 9 khz to 4.5/6.5/9 GHz E5092A Configurable Multiport Test Set Configuration Guide 02 Keysight 5080A Network Analyzer & E5092A Configurable Multiport Test Set
Cable Analysis and Fault Detection using the Bode 100
Cable Analysis and Fault Detection using the Bode 100 By Stephan Synkule 2014 by OMICRON Lab V1.3 Visit www.omicron-lab.com for more information. Contact [email protected] for technical support.
R&S ZCxxx Millimeter-Wave Converters Specifications
ZCxxx_dat-sw_en_3607-1471-22_v0200_cover.indd 1 Data Sheet 02.00 Test & Measurement R&S ZCxxx Millimeter-Wave Converters Specifications 21.07.2015 15:09:16 CONTENTS Definitions... 3 General information...
Lab 1: The Digital Oscilloscope
PHYSICS 220 Physical Electronics Lab 1: The Digital Oscilloscope Object: To become familiar with the oscilloscope, a ubiquitous instrument for observing and measuring electronic signals. Apparatus: Tektronix
R&S SMZ Frequency Multiplier Specifications
Test & Measurement Data Sheet 02.00 R&S SMZ Frequency Multiplier Specifications CONTENTS Definitions... 3 Specifications... 4 RF performance...4 Frequency...4 Level...4 Spectral purity...4 Connectors...5
High Power Programmable DC Power Supplies PVS Series
Data Sheet High Power Programmable DC Power Supplies The PVS10005, PVS60085, and PVS60085MR programmable DC power supplies offer clean output power up to 5.1 kw, excellent regulation, and fast transient
RF Power Amplifier PA10W Owner s Manual SpinCore Technologies, Inc. http://www.spincore.com
RF Power Amplifier PA10W Owner s Manual SpinCore Technologies, Inc. http://www.spincore.com Congratulations and thank you for choosing a design from SpinCore Technologies, Inc. We appreciate your business!
A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance.
A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance. Bulletin -01E http://www.yokogawa.com/tm/... Visit our website to sign for e-mail updates Compact,
Agilent Television Power Consumption Testing. Application Note
Agilent Television Power Consumption Testing Application Note Introduction Today, there are many types of televisions (TVs) on the market: the cathode ray tube (CRT) TV, liquid crystal display (LCD) TV,
Instruction Sheet ACS-101. General Description. Specifications. Amplified Broadband UHF Combiner-Splitter. Overall. Antenna Splitter.
ACS-101 Amplified Broadband UHF Combiner-Splitter General Description The ACS-101 (Antenna Combiner Splitter 10 to 1) is an amplified and filtered broadband splitter-combiner. It allows up to 10 base stations
Agilent E6020B FTTx OTDR
Agilent E6020B FTTx OTDR Fast and Cost-effective Fiber Installation for Access Networks Technical Data Sheet Introducing the New FTTx OTDR Agilent's new E6020B FTTx OTDR is a cost-effective, easy to use
A PC-BASED TIME INTERVAL COUNTER WITH 200 PS RESOLUTION
35'th Annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting San Diego, December 2-4, 2003 A PC-BASED TIME INTERVAL COUNTER WITH 200 PS RESOLUTION Józef Kalisz and Ryszard Szplet