1 R3765/67 CG Network Analyzer RSE
2 R376XG Series Overview R kHz ~ 3.8 GHz R kHz ~ 8 GHz AG BG Basic model Built-in Bridge A/R & B/R Transmission Reflection CG Built-in S-parameter Trans & Refl S11,S21,S22,S12 S11&S21 S22&S12 CG+opt.11 Built-in 3 port test set S11,S21,S22,S12 S11,S31,S33,S13 S22,S32,S33,S23 S11&S21,S22&S12 S11&S31,S33&S13 S22&S32,S33&S23 CG+opt.14 Built-in 4 port test set S11,S21,S31,S41 S22,S12,S32,S42 S33,S13,S23,S43 S44,S14,S24,S34 (and twin traces) RSE
3 Four independent display channels...with eight traces on one screen S11 & S21 S33 & S13 S22 & S12 S11 & S31 RSE
4 Automatic calibration kit R17050 : Automatic Calibration Kit (optional), controlled via RS232 from network analyzer Frequency range : 40MHz - 8GHz Measuring accuracy : dB(Typical) Option : R opt-01 female - female (3.5 mm connector) R opt-02 male - male (3.5 mm connector) R opt-03 female - male (3.5 mm connector) RSE
5 Extended Analysis Functions Multiport device measurements - Built-in 3 port /4 port Test Set (Option 11, 14) - 5 port & 6 port multiport adapter (R ,11,12) - Four independent display channels (8 Traces on one screen) - 3 port Full Calibration & 4 port Full Calibration TDR Analysis,CDMA Filter Analysis - Time Domain Analysis Function (Option 70) - Joint use of Time Domain Analysis and GATE Function - CDMA IF Filter Analysis Function Electrical Step Attenuator (Option 10) RSE
6 - Built-in 3-port and 4-port test set (Opt 11/14) a R A NET WOR KANALYZE R S11,S12,S13 S21,S22,S23 S31,S32,S33 3 paths, 9 parameters (opt 11) P1 P2 DUT P3 OPT 11 P4 OPT 14 S11 S12 S13 S14 S21 S22 S23 S24 S31 S32 S33 S34 S41 S42 S43 S44 6 paths, 16 parameters (opt 14) RSE
7 External multiport adapter R3967 DUT R opt 10 : 5 port test adapter (Transmission, Reflection for 5 port applications) R opt 11 : 6 port test adapter (Transmission, Reflection for 6 port applications) R opt 12 : 6 port test adapter (Transmission, Reflection, Isolation for 6 port applications) Example : R3767CG+ opt11& R3967+ opt10 The test adapter has to be connected to R3765/7 CG + opt 11 RSE
8 TDR Analysis (Opt 70) Time and distance scaling RSE
9 Electrical step attanuator (Opt 10) Specifications Attenuation step : 20dB, 40dB, 60dB (Set by each port) Output signal level : - C model + 5 to -75 dbm (opt , ATT Auto) + 3 to -75 dbm (opt , ATT Auto) {+10 to -10 dbm (Standard,opt 11), +8 to -10dBm(opt14)} - B model + 2 to -78 dbm (ATT Auto) {+ 7 to -13 dbm} - A model +12 to -68 dbm (ATT Auto) {+17 to - 3 dbm} { }:Standard output signal level Attenuation Accuracy: Attenuation 20 db: +/- 3 db Attenuation 40 db: +/- 4 db Attenuation 60 db: +/- 5 db RSE
10 Software Fixture (opt 71/72) Simulation functions Impedance conversion function Add Matching Network function Delete Matching Network function Balance Degree measurement function Balance conversion function Mixed mode analysis RSE
11 Trend of High Frequency Filters RF Signal IC( differential device) Noise IF Z in 50 ohm Z out 150 ohm Matching Network Signal Local signal The characteristics of differential devices : - Good for Endurance Noise characteristic - Direct connection to IC (differential device) - 3 or 4 port device - Each port has a different impedance - A Matching Network is required RSE
12 Impedance conversion function (Opt 71/72) Example Possibility to set a different impedance at each port ( 10 Ohm to 1K Ohm) Zo:50 Ohm 25Ohm DUT Zo:50 ohm 75 Ohm Zo conv. Zo conv. PORT 1 PORT 2 Zo:50 ohm 25Ohm PORT 3 PORT 4 Zo conv. Zo conv. Zo:50 ohm 75 Ohm RSE
13 Add Matching Network function (Opt 71/72) PORT 1 DUT PORT 3 Built-in circuits PORT 2 PORT 4 C(P)-L(S)-P Capacitance(Parallel)-Inductance(Series)-Device Port L(P)-C(S)-P Inductance(Parallel)-Capacitance(Series)-Device Port C(S)-L(P)-P Capacitance(Series)-Inductance(Parallel)-Device Port L(S)-C(P)-P Inductance(Series)-Capacitance(Parallel)-Device Port L(P)-C(P)-P Inductance(Parallel)-Capacitance(Parallel)-Device Port Other circuits can be simulated by simulation software (Touchstone format) RSE
14 Add Matching Network function (2) (Opt 71) A matching network (LC ) can be added between ports (P1 to P2 & P3 to P4) DUT Matching network RSE
15 Delete Matching network function (Opt 71/72) Delete a hardware matching circuit by using S parameter file in Touchstone format PORT1 PORT2 Port Extension Port Extension Subtract User circuit Subtract User circuit DUT Subtract User circuit Subtract User circuit Port Extension Port Extension PORT3 PORT4 Extending point of Testing standard plane Extending point of Testing standard plane RSE
16 Delete Matching network function(2) (Opt 71/72) Possibility to measure the real device characteristics The DUT characteristics can be measured directly, deleting the influence of the strip lines. RSE
17 Delete Matching network function(3) (Opt 71/72) Measuring example Including physical circuit specifications (Circuit + DUT) Excluding physical circuit specifications (DUT only) RSE
18 Balance Degree Measurement (Opt 71) Possibility to measure Level and Phase of balance degree between the ports P1 P2 P3 Balance degree : Between P1 and P2 : B12 = -(S13-S14)/(S23-S24) Between P2 and P1: B21 = -(S23-S24)/(S13-S14) Between P2 and P3 : B23 = -(S21/S31) Between P3 and P2 : B32 = -(S31/S21) Between P3 and P4 : B34 = -(S31-S32)/(S41-S42) Between P4 and P3 : B43 = -(S41-S42)/(S31-S32) P1 P3 P4 P2 RSE
19 Balance Conversion function (Opt 71) Possibility to measure a 4-port device as two-port device by using a balun PORT 1 PORT 1 DU PORT 3 PORT 2 T PORT 2 PORT 4 RSE
20 Balance Conversion function (2) (Opt 71) Two types of Baluns (Differential & Floating Balun) DUT Z1 Z1 2 Z2 Z12>>Z1,Z2 Z12<<Z1,Z2 Differential Balun Floating Balun RSE
21 Balance Conversion function (3) (Opt 71) Measurement result with Differential Balun Z= ohm DUT Differential Balun Z=0 ohm Z RSE
22 Balance Conversion function (4) (Opt 71) Measurement result with Floating Balun No change in characteristics between Z = to 0 ohm DUT Floating Balun Z RSE
23 Mixed Mode Analysis (Opt 71) Common mode Analysis : - Differential input - Differential output Analysis : Sdd - Differential input - Common output Analysis : Scd - Common input - Differential output Analysis : Sdc - Common input - Common output Analysis : Scc DUT Vc in Vd in Vd out Vc out RSE
24 of Software Fixture PORT 1 PORT1 PORT3 PORT 2 Zo con v. Zo con v. DU T Zo con v. Zo con v. PORT2 PORT4 Simulation by Software Fixture RSE
25 Customer benefits Why should you buy this network analyzer? 3/4 port test sets implemented : Unique solution 3/4 port full calibration possible Simulations in realtime Balanced measurments possible RSE
Impedance 50 (75 connectors via adapters)
VECTOR NETWORK ANALYZER PLANAR TR1300/1 DATA SHEET Frequency range: 300 khz to 1.3 GHz Measured parameters: S11, S21 Dynamic range of transmission measurement magnitude: 130 db Measurement time per point:
Agilent Balanced Measurement Example: Differential Amplifiers
Agilent Balanced Measurement Example: Differential Amplifiers Application Note 1373-7 Introduction Agilent Technologies has developed a solution that allows the most accurate method available for measuring
Agilent Test Solutions for Multiport and Balanced Devices
Agilent Test Solutions for Multiport and Balanced Devices Duplexer test solutions 8753ES option H39/006 During design and final alignment of duplexers, it is often necessary to see both the transmit-antenna
Revision 1.10 April 7, 2015 Method of Implementation (MOI) for 100BASE-TX Ethernet Cable Tests Using Keysight E5071C ENA Option TDR
Revision 1.10 April 7, 2015 Method of Implementation (MOI) for 100BASE-TX Ethernet Cable Tests Using Keysight E5071C ENA Option TDR 1 Table of Contents 1. Revision History... 3 2. Purpose... 3 3. References...
iva Cable & Antenna Analyzer
iva Cable & Antenna Analyzer VSWR, Return Loss Measurement & Distance to Fault The iva Series Cable & Antenna Analyzer is an exciting new product from Kaelus that enables users to accurately measure VSWR/return
Agilent 8753ET/8753ES Network Analyzers
Agilent 8753ET/8753ES Network Analyzers 8753ET, 300 khz to 3 or 6 GHz 8753ES, 30 khz to 3 or 6 GHz Configuration Guide System configuration summary The following summary lists the main components required
Comparison of Vector Network Analyzer and TDA Systems IConnect Generated S-Parameters
Comparison of Vector Network Analyzer and TDA Systems IConnect Generated S-Parameters Purpose: This technical note presents single-ended insertion loss ( SE IL) and return loss ( SE RL) data generated
MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER
MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER W. Li, J. Vandewege Department of Information Technology (INTEC) University of Gent, St.Pietersnieuwstaat 41, B-9000, Gent, Belgium Abstract: Precision
Experiment 7: Familiarization with the Network Analyzer
Experiment 7: Familiarization with the Network Analyzer Measurements to characterize networks at high frequencies (RF and microwave frequencies) are usually done in terms of scattering parameters (S parameters).
2. The Vector Network Analyzer
ECE 584 Laboratory Experiments 2. The Vector Network Analyzer Introduction: In this experiment we will learn to use a Vector Network Analyzer to measure the magnitude and phase of reflection and transmission
EMC Basics. Speaker : Alain Lafuente. [email protected]
EMC Basics Speaker : lain Lafuente [email protected] WHT IS EMC? 2 CE Marking With the formation of the single European market, standardization was required to remove technical barriers to trade.
iva Cable & Antenna Analyzer
iva Cable & Antenna Analyzer VSWR, Return Loss Measurement & Distance to Fault The iva Series Cable & Antenna Analyzer is an exciting new product from Kaelus that enables users to accurately measure VSWR/return
Primer of investigation of 90- degree, 45-degree and arched bends in differential line
Simbeor Application Note #2009_02, April 2009 2009 Simberian Inc. Primer of investigation of 90- degree, 45-degree and arched bends in differential line Simberian, Inc. www.simberian.com Simbeor : Easy-to-Use,
Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers
Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers N4690 Series, 2-port Microwave ECal 85090 Series, 2-port RF ECal N4430 Series, 4-port ECal Technical Overview Control ECal directly
Agilent De-embedding and Embedding S-Parameter Networks Using a Vector Network Analyzer. Application Note 1364-1
Agilent De-embedding and Embedding S-Parameter Networks Using a Vector Network Analyzer Application Note 1364-1 Introduction Traditionally RF and microwave components have been designed in packages with
One Port Network Analyzer
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com One Port Network Analyzer 5.4GHz Impendance : 50Ω(75Ωconnectors via adapters) Test
Agilent 10 Hints for Making Better Network Analyzer Measurements. Application Note 1291-1B
Agilent 10 Hints for Making Better Network Analyzer Measurements Application Note 1291-1B Contents HINT 1. Measuring high-power amplifiers HINT 2. Compensating for time delay in cable HINT 3. Improving
February 2010 Number 201001. Vector Network Analyzer upgrade to SureCAL Power Sensor and RF Components Packages
February 2010 Number 201001 Vector Network Analyzer upgrade to SureCAL Power Sensor and RF Components Packages Overview: This Technical Note describes the addition of Vector Network Analyzer (VNA) measurement
UNDERSTANDING NOISE PARAMETER MEASUREMENTS (AN-60-040)
UNDERSTANDING NOISE PARAMETER MEASUREMENTS (AN-60-040 Overview This application note reviews noise theory & measurements and S-parameter measurements used to characterize transistors and amplifiers at
Measuring RF Parameters of Networks Bill Leonard NØCU
Measuring RF Parameters of Networks Bill Leonard NØCU NAØTC - 285 TechConnect Radio Club http://www.naøtc.org/ What is a Network? A Network is a group of electrical components connected is a specific way
The Application of Vector Network Analyzers in Balanced Transmission Line Signal Integrity Measurements
1 The Application of Vector Network Analyzers in Balanced Transmission Line Signal Integrity Measurements Agenda 1. Introduction 1.1 The Application and Advantages of Balanced Transmission Lines 1.2 Important
AVR2004: LC-Balun for AT86RF230. Application Note. Features. 1 Introduction
AVR2004: LC-Balun for AT86RF230 Features Balun for AT86RF230 with lumped elements Simulation results S-Parameter file 1 Introduction In some cases the used balun on the ATAVR RZ502 Radio Boards must be
Techniques for Precise Cable and Antenna Measurements in the Field
Techniques for Precise Cable and Antenna Measurements in the Field Using FieldFox handheld analyzers Application Note This application note introduces the practical aspects of cable and antenna testing,
Applying Error Correction to Network Analyzer Measurements. Application Note 1287-3. Table of Contents. Page
Applying Error Correction to Network Analyzer Measurements Application Note 287-3 Table of Contents Page Introduction 2 Sources of Errors and Types of Errors 3 Types of Error Correction 4 One-Port 4 The
HPM-5 Performance Testing
HPM-5 Performance Testing Test 234 JF Sawdy 7/3/02 Samples: Double-ended 2mm cable assemblies: 3, 6 and 8 meters end-to-end, using Meritec s 700219-01 28 awg twinax cable and Meritec s HPM-5 connectors
Network analyzer and spectrum analyzer two in one
R&S ZVL Vector Network Analyzer Network analyzer and spectrum analyzer two in one The R&S ZVL is the lightest and smallest vector network analyzer in its class. On top of this, it can be used as a full-featured
A Network Analyzer For Active Components
A Network Analyzer For Active Components EEEfCom 29-30 Juni ULM Marc Vanden Bossche, NMDG Engineering Remi Tuijtelaars, BSW Copyright 2005 NMDG Engineering Version 2 Outline Review of S-parameters Theory
Category 8 Cable Transmission Measurements Comparative Study between 4-port single wire measurements and 2-port balun measurements
Category 8 Cable Transmission Measurements Comparative Study between 4-port single wire measurements and 2-port balun measurements Stefan Estevanovich Rafael Herrera, Nadim Kafati Hitachi Cable USA NDC
Michael Hiebel. Fundamentals of Vector Network Analysis
Michael Hiebel Fundamentals of Vector Network Analysis TABIH OF CONTENTS Table of contents 1 Introduction 12 1.1 What is a network analyzer? 12 1.2 Wave quantities and S-parameters 13 1.3 Why vector network
Calibration Procedure for Measuring S-Parameters in Balun Applications on 150-Ω High-Speed Cables
NASA/TM 2012-217296 Calibration Procedure for Measuring S-Parameters in Balun Applications on 150-Ω High-Speed Cables Onoufrios Theofylaktos and Joseph D. Warner Glenn Research Center, Cleveland, Ohio
PLANAR 304/1 Vector Network Analyzer. Operating Manual
PLANAR 304/1 Vector Network Analyzer Operating Manual 2012 T A B L E O F C O N T E N T S INTRODUCTION... 8 SOFTWARE VERSIONS... 8 SAFETY INSTRUCTIONS... 9 1 GENERAL OVERVIEW... 11 1.1 Description... 11
Balun Parameter Definitions & Measurement May 2004
Balun Parameter Definitions & Measurement May 2004 Differential circuits are becoming more widely used in RF circuits for the same reason that they have been used for years in lower frequency circuits.
R&S ZVA Vector Network Analyzer High performance up to 110 GHz with up to four test ports
R&S ZVA Vector Network Analyzer High performance up to 110 GHz with up to four test ports Test & Measurement Product Brochure 09.00 R&S ZVA Vector Network Analyzer At a glance The R&S ZVA series is the
Cable Impedance and Structural Return Loss Measurement Methodologies
Cable Impedance and Structural Return Loss Measurement Methodologies Introduction Joe Rowell Joel Dunsmore and Les Brabetz Hewlett Packard Company Santa Rosa, California Two critical electrical specifications
Keysight Technologies Understanding the Fundamental Principles of Vector Network Analysis. Application Note
Keysight Technologies Understanding the Fundamental Principles of Vector Network Analysis Application Note Introduction Network analysis is the process by which designers and manufacturers measure the
Performing Amplifier Measurements with the Vector Network Analyzer ZVB
Product: Vector Network Analyzer R&S ZVB Performing Amplifier Measurements with the Vector Network Analyzer ZVB Application Note This document describes typical measurements that are required to be made
E5092A Configurable Multiport Test Set
Keysight Technologies E5080A Network Analyzer 9 khz to 4.5/6.5/9 GHz E5092A Configurable Multiport Test Set Configuration Guide 02 Keysight 5080A Network Analyzer & E5092A Configurable Multiport Test Set
R&S ZVA Vector Network Analyzer High performance up to 67 GHz with up to four test ports
Test & Measurement Product Brochure 06.01 ООО "Техэнком" Контрольно-измерительные приборы и оборудование www.tehencom.com R&S ZVA Vector Network Analyzer High performance up to 67 GHz with up to four test
S-PARAMETER MEASUREMENTS OF MEMS SWITCHES
Radant MEMS employs adaptations of the JMicroTechnology test fixture depicted in Figure 1 to measure MEMS switch s-parameters. RF probeable JMicroTechnology microstrip-to-coplanar waveguide adapter substrates
R&S ZVA Vector Network Analyzer Specifications
www.atecorp.com 8-44-ATEC (2832) R&S ZVA Vector Network Analyzer Specifications ZVA_dat-sw_en_523-568-22_v_cover.indd Data Sheet. E stablished 98 Advanced Test Equipment Rentals Test & Measurement 4.5.22
Agilent 8510-13 Measuring Noninsertable Devices
Agilent 8510-13 Measuring Noninsertable Devices Product Note A new technique for measuring components using the 8510C Network Analyzer Introduction The majority of devices used in real-world microwave
S-parameter Simulation and Optimization
S-parameter Simulation and Optimization Slide 5-1 S-parameters are Ratios Usually given in db as 20 log of the voltage ratios of the waves at the ports: incident, reflected, or transmitted. S-parameter
Designing the NEWCARD Connector Interface to Extend PCI Express Serial Architecture to the PC Card Modular Form Factor
Designing the NEWCARD Connector Interface to Extend PCI Express Serial Architecture to the PC Card Modular Form Factor Abstract This paper provides information about the NEWCARD connector and board design
Basics of RF Amplifier Measurements with the E5072A ENA Series Network Analyzer
Basics of RF Amplifier Measurements with the E5072A ENA Series Network Analyzer Application Note Introduction The RF power amplifier is a key component used in a wide variety of industries such as wireless
Agilent AN 1287-5 Improving Throughput in Network Analyzer Applications. Application Note
Agilent AN 1287-5 Improving Throughput in Network Analyzer Applications Application Note Table of Contents 2 3 5 12 13 15 18 20 20 20 21 22 23 Introduction Throughput Considerations Sweep Speed Instrument
Network Analyzer Operation
Network Analyzer Operation 2004 ITTC Summer Lecture Series John Paden Purposes of a Network Analyzer Network analyzers are not about computer networks! Purposes of a Network Analyzer Measures S-parameters
RF Network Analyzer Basics
RF Network Analyzer Basics A tutorial, information and overview about the basics of the RF Network Analyzer. What is a Network Analyzer and how to use them, to include the Scalar Network Analyzer (SNA),
R&S ZNBT8 Vector Network Analyzer Specifications
ZNBT8_dat-sw_en_3606-9727-22_v0200_cover.indd 1 Data Sheet 02.00 Test & Measurement R&S ZNBT8 Vector Network Analyzer Specifications 20.05.2014 08:39:42 CONTENTS Definitions... 3 Measurement range... 4
Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz
Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar Network Analyzer combines a 90 db wide dynamic range with the accuracy and linearity
DSA800 Series Spectrum Analyzer
DSA800 Series Spectrum Analyzer Configuration Guide This guide is used to help users to configure DSA800 series spectrum analyzer according to their requirements. You can get an overall understanding of
Agilent 8720 Family Microwave Vector Network Analyzers
Agilent 8720 Family Microwave Vector Network Analyzers Product Overview High-Performance Solutions for Your Measurement Challenges Now more choices for solving your measurement challenges What's new in
MEASUREMENT OF CRYOGENIC PERFORMANCE OF 4-8 GHz PAMTECH ISOLATORS S/N 108-112. Juan Daniel Gallego Isaac López Fernández Carmen Diez González
MEASUREMENT OF CRYOGENIC PERFORMANCE OF 4-8 GHz PAMTECH ISOLATORS S/N 108-112 May 2000 TECHNICAL REPORT C.A.Y. 2000-2 ABSTRACT This report presents the results of the measurements of input and output reflection,
Agilent E5063A ENA Series Network Analyzer. 100 khz to 4.5/ 8.5/18 GHz
Agilent E5063A ENA Series Network Analyzer 100 khz to 4.5/ 8.5/18 GHz The Best Balance Between Price and Performance The E5063A is a low cost network analyzer for simple passive component testing up to
What are the Requirements for an Accurate DSL Line Simulator? Paradyne International, France
Title: Source: Author: Contact: What are the Requirements for an Accurate DSL Line Simulator? Paradyne International, France Jack Douglass Jack Douglass Paradyne Networks, Inc. Voice: 949-233-3558 Email:
LAP NODO ÓPTICO 2/4 SALIDAS WT-8604JL
2/4 SALIDAS WT-8604JL Latin American Power. CABA, Argentina. www.latinamericanpower.com 1 WT-8604JL OPTICAL RECEIVER 1 - DESCRIPTION WT-8604JL is our new high-class 4-way output CATV optical receiver.
EE 186 LAB 2 FALL 2004. Network Analyzer Fundamentals and Two Tone Linearity
Network Analyzer Fundamentals and Two Tone Linearity Name: Name: Name: Objective: To become familiar with the basic operation of a network analyzer To use the network analyzer to characterize the in-band
The N2PK Vector Network Analyzer (N2PK VNA) Original by Paul Kiciak, N2PK, 2007 * (*Pages edited or added by VE7WRS, 2009)
The N2PK Vector Network Analyzer (N2PK VNA) Original by Paul Kiciak, N2PK, 2007 * (*Pages edited or added by VE7WRS, 2009) What Does Vector Mean?! Vector: magnitude & direction (angle) 01/22/07 N2PK *
Impedance Matching of Filters with the MSA Sam Wetterlin 2/11/11
Impedance Matching of Filters with the MSA Sam Wetterlin 2/11/11 Introduction The purpose of this document is to illustrate the process for impedance matching of filters using the MSA software. For example,
0HDVXULQJWKHHOHFWULFDOSHUIRUPDQFH FKDUDFWHULVWLFVRI5),)DQGPLFURZDYHVLJQDO SURFHVVLQJFRPSRQHQWV
0HDVXULQJWKHHOHFWULFDOSHUIRUPDQFH FKDUDFWHULVWLFVRI5),)DQGPLFURZDYHVLJQDO SURFHVVLQJFRPSRQHQWV The treatment given here is introductory, and will assist the reader who wishes to consult the standard texts
Eye Doctor II Advanced Signal Integrity Tools
Eye Doctor II Advanced Signal Integrity Tools EYE DOCTOR II ADVANCED SIGNAL INTEGRITY TOOLS Key Features Eye Doctor II provides the channel emulation and de-embedding tools Adds precision to signal integrity
EMC Expert System for Architecture Design
EMC Expert System for Architecture Design EMC Expert System for Architecture Design Marcel van Doorn [email protected] Philips Electromagnetics Competence Center High Tech Campus 26, 5656 AE
COUPLING / DECOUPLING NETWORK (CDN) FOR UNSCREENED BALANCED PAIRS
IEC / EN 61000-4-6 specifies the design and performance of a range of coupling / decoupling networks (CDNs). Each CDN is specific to the type of cable and the intended signal carried on the cable. Teseq
Noise Figure Measurement without a Noise Source on a Vector Network Analyzer
Noise Figure Measurement without a Noise Source on a Vector Network Analyzer Application Note Products: &S ZVA &S ZVT &S ZVAB-K30 &S NP-Z55 This application note describes the noise figure measurement
FRAUNHOFER INSTITUTE FOR INTEg RATEd CIRCUITS IIS. drm TesT equipment
FRAUNHOFER INSTITUTE FOR INTEg RATEd CIRCUITS IIS drm TesT equipment dt230 playback of drm signals recording of drm signals channel simulation receiver performance analysis real-time modulation Architecture
Recommendations for TDR configuration for channel characterization by S-parameters. Pavel Zivny IEEE 802.3 100GCU Singapore, 2011/03 V1.
Recommendations for TDR configuration for channel characterization by S-parameters Pavel Zivny IEEE 802.3 100GCU Singapore, 2011/03 V1.0 Agenda TDR/TDT measurement setup TDR/TDT measurement flow DUT electrical
Agilent Technologies Measuring Frequency Response with the LF Network Analyzer
Agilent Technologies Measuring Frequency Response with the LF Network Analyzer Application Note Introduction This application note describes basics of frequency response measurements with a LF network
Agilent PN 8753-1 RF Component Measurements: Amplifier Measurements Using the Agilent 8753 Network Analyzer. Product Note
Agilent PN 8753-1 RF Component Measurements: Amplifier Measurements Using the Agilent 8753 Network Analyzer Product Note 2 3 4 4 4 4 6 7 8 8 10 10 11 12 12 12 13 15 15 Introduction Table of contents Introduction
Agilent FieldFox RF Vector Network Analyzer N9923A Quick Reference Guide
Contents Agilent FieldFox RF Vector Network Analyzer N9923A Quick Reference Guide Do You Have Everything?... 2 The Power Button and LED... 2 Battery Usage... 3 Measure S-Parameters... 4 Multi-Trace Configurations...
Power Amplifier Gain Compression Measurements
Technical Brief Power Amplifier Gain Compression Measurements GPIB Private Bus Sweep Out Sweep In Pulse In AC Mod Out Blank/Marker Out Blanking In Overview The 1 db gain compression of an amplifier describes
HP 8753E RF Vector Network Analyzer. Technical Specifications. 30 khz to 3 GHz or 6 GHz. HP 8753E maximizes versatility and performance
HP 8753E RF Vector Network Analyzer Technical Specifications 30 khz to 3 GHz or 6 GHz The HP 8753E RF vector network analyzer provides all the performance and productivity features to simplify and speed
Agilent AN 1287-9 In-Fixture Measurements Using Vector Network Analyzers
Agilent AN 1287-9 In-Fixture Measurements Using Vector Network Analyzers Application Note Agilent Network Analysis Solutions Table of Contents 3 3 4 4 5 5 6 7 8 12 13 13 13 15 16 17 17 17 17 18 18 19 19
Standex-Meder Electronics. Custom Engineered Solutions for Tomorrow
Standex-Meder Electronics Custom Engineered Solutions for Tomorrow RF Reed Relays Part II Product Training Copyright 2013 Standex-Meder Electronics. All rights reserved. Introduction Purpose Designing
Understanding the Fundamental Principles of Vector Network Analysis. Application Note 1287-1. Table of Contents. Page
Understanding the Fundamental Principles of Vector Network Analysis Application Note 1287-1 Table of Contents Page Introduction 2 Measurements in Communications Systems 2 Importance of Vector Measurements
Agilent 8712ET/ES, 8714ET/ES RF Economy Network Analyzers Product Overview. Speed, accuracy, and productivity features, at a price you can afford
Agilent 8712ET/ES, 8714ET/ES RF Economy Network Analyzers Product Overview 8712ET and 8712ES, 300 khz to 1.3 GHz 8714ET and 8714ES, 300 khz to 3 GHz Speed, accuracy, and productivity features, at a price
Scalar Network Analysis with the HP 8590 Series Spectrum Analyzers Product Overview
This literature was published years prior to the establishment of Agilent Technologies as a company independent from Hewlett-Packard and describes products or services now available through Agilent. It
Shielding Effectiveness Test Method. Harbour s LL, SB, and SS Coaxial Cables. Designs for Improved Shielding Effectiveness
Shielding Effectiveness Test Method Harbour s LL, SB, and SS Coaxial Cables Designs for Improved Shielding Effectiveness Harbour Industries 4744 Shelburne Road Shelburne Vermont 05482 USA 802-985-3311
Making Spectrum Measurements with Rohde & Schwarz Network Analyzers
Making Spectrum Measurements with Rohde & Schwarz Network Analyzers Application Note Products: R&S ZVA R&S ZVB R&S ZVT R&S ZNB This application note describes how to configure a Rohde & Schwarz Network
RF Communication System. EE 172 Systems Group Presentation
RF Communication System EE 172 Systems Group Presentation RF System Outline Transmitter Components Receiver Components Noise Figure Link Budget Test Equipment System Success Design Remedy Transmitter Components
Improving Network Analyzer Measurements of Frequency-translating Devices Application Note 1287-7
Improving Network Analyzer Measurements of Frequency-translating Devices Application Note 1287-7 - + - + - + - + Table of Contents Page Introduction......................................................................
Probes and Setup for Measuring Power-Plane Impedances with Vector Network Analyzer
Probes and Setup for Measuring Power-Plane Impedances with Vector Network Analyzer Plane impedance measurement with VNA 1 Outline Introduction, Y, and S parameters Self and transfer impedances VNA One-port
Network Analyzer Basics- EE142 Fall 07
- EE142 Fall 07 Lightwave Analogy to RF Energy Incident Transmitted Reflected Lightwave DUT RF Why Do We Need to Test Components? Verify specifications of building blocks for more complex RF systems Create
LARGE-SIGNAL NETWORK ANALYZER MEASUREMENTS AND THEIR USE IN DEVICE MODELLING
Ewout Vandamme (Agilent Technologies, NMDG), Wladek Grabinski (Motorola, Geneva), Dominique Schreurs (K.U.Leuven), and Thomas Gneiting (ADMOS) LARGE-SIGNAL NETWORK ANALYZER MEASUREMENTS AND THEIR USE IN
Six-Port Reflectometer: an Alternative Network Analyzer for THz Region. Guoguang Wu
Six-Port Reflectometer: an Alternative Network Analyzer for THz Region Guoguang Wu Outline General Background of Network Analyzer Principles of Six-Port Reflectometer WR-15 Six-port Reflectometer Design,
A Small, Simple, USB-Powered Vector Network Analyzer Covering 1 khz to 1.3 GHz
Prof. Dr. Thomas C. Baier, DG8SAQ University of Applied Sciences, Prittwitzstrasse 10, 89075 Ulm, Germany; [email protected] A Small, Simple, USB-Powered Vector Network Analyzer Covering 1 khz to 1.3 GHz
1. The Slotted Line. ECE 584 Microwave Engineering Laboratory Experiments. Introduction:
ECE 584 Microwave Engineering Laboratory Experiments 1. The Slotted Line Introduction: In this experiment we will use a waveguide slotted line to study the basic behavior of standing waves and to measure
Agilent PNA Network Analyzers 10 MHz to 110 GHz
Agilent PNA Network Analyzers 10 MHz to 110 GHz Meeting your measurement needs today and into the future... Exceptional performance Advanced automation Flexible connectivity Easy-to-use PNA Network Analyzers
E5061B-3L5 LF-RF Network Analyzer with Option 005 Impedance Analysis Function. Data Sheet
E506B-3L5 LF-RF Network Analyzer with Option 005 Impedance Analysis Function Data Sheet E506B-3L5 with Option 005; NA plus ZA in one box To ensure the performance and reliability of electronic equipment,
RF and Microwave Accessories. CD-ROM Catalog. Find the right component for your Rohde & Schwarz test & measurement equipment
RF and Microwave Accessories CD-ROM Catalog Find the right component for your Rohde & Schwarz test & measurement equipment Product group Typical applications Adapters Interchanging of various connector
Cable Analysis and Fault Detection using the Bode 100
Cable Analysis and Fault Detection using the Bode 100 By Stephan Synkule 2014 by OMICRON Lab V1.3 Visit www.omicron-lab.com for more information. Contact [email protected] for technical support.
MEASUREMENT SET-UP FOR TRAPS
Completed on 26th of June, 2012 MEASUREMENT SET-UP FOR TRAPS AUTHOR: IW2FND Attolini Lucio Via XXV Aprile, 52/B 26037 San Giovanni in Croce (CR) - Italy [email protected] Trappole_01_EN 1 1 DESCRIPTION...3
Card electrical characteristic, Parallelism & Reliability. Jung Keun Park Willtechnology
Description of the MEMS CIS Probe Card electrical characteristic, Parallelism & Reliability Jung Keun Park Willtechnology Background Overview Design limitation, Things to consider, Trend CIS Probe Card
Spectrum Analyzers And Network Analyzers. The Whats, Whys and Hows...
Spectrum Analyzers And Network Analyzers The Whats, Whys and Hows... Bertrand Zauhar, VE2ZAZ [email protected] June 2010 Today's Program Definitions of Spectrum and Network Analyzers, Differences between
Distance-To-Fault (DTF) Measurement in 75 Ohm Systems with the R&S FSH3-TV
Products: R&S FSH3-TV Distance-To-Fault (DTF) Measurement in 75 Ohm Systems with the R&S FSH3-TV Application Note Measuring cable characteristics is important when it comes to installing and servicing
How To Use A Sound Card With A Subsonic Sound Card
!"## $#!%!"# &"#' ( "#' )*! #+ #,# "##!$ -+./0 1" 1! 2"# # -&1!"#" (2345-&1 #$6.7 -&89$## ' 6! #* #!"#" +" 1##6$ "#+# #-& :1# # $ #$#;1)+#1#+
1000BASE-T1: 3-Port Conversion/Balance Measurement for Cables and Components
1000BASE-T1: 3-Port Conversion/Balance Measurement for Cables and Components April 1, 2014 Neven Pischl, Broadcom Ahmad Chini, Broadcom Mehmet Tazebay, Broadcom Version 1.0 IEEE 802.3bp Channel Ad Hoc
How To Measure Power Loss On A Cable Or Antenna System
Understanding Cable & Antenna Analysis www.anritsu.com In this guide, the fundamentals of line sweeping cable and antenna systems are discussed. After reading this guide, the reader will understand what
Low Cost, Triple Balanced, LTCC Mixer
Low Cost, Triple Balanced, LTCC Mixer Introduction Double Balanced Mixers are used widely in frequency translation applications. Some of the advantages of the double balanced mixer are good L-R and L-I
R&S ZNC Vector Network Analyzer Specifications
ZNC3_dat-sw_en_5214-5610-22_v0300_cover.indd 1 Data Sheet 03.00 Test & Measurement R&S ZNC Vector Network Analyzer Specifications 04.09.2012 13:39:47 CONTENTS Definitions... 3 Measurement range... 4 Measurement
ECE 435 INTRODUCTION TO THE MICROWAVE NETWORK ANALYZER
ECE 435 INTRODUCTION TO THE MICROWAVE NETWORK ANALYZER Latest revision: October 1999 Introduction A vector network analyzer (VNA) is a device capable of measuring both the magnitude and phase of a sinusoidal
GaAs Switch ICs for Cellular Phone Antenna Impedance Matching
GaAs Switch ICs for Cellular Phone Antenna Impedance Matching IWATA Naotaka, FUJITA Masanori Abstract Recently cellular phones have been advancing toward multi-band and multi-mode phones and many of them