E 3 Point. Toxic and Combustible Gas Detector Network Platform (BACnet MS-TP, Modbus) PRODUCT SUBMITTAL ORDERING INFORMATION



Similar documents
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Sensor for Ammonia West 83 rd Terrace or fax

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Buckeye Detection Systems Fixed Detection Systems Application Survey

DUCT SMOKE DETECTOR D4120

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Radiant Temperature Sensor TY7321

Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

T7560A,B,C Digital Wall Module

Fire & Security DETECTORS

Ammonia Detection System Codes and Design Specifications

CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter

Ultima X Series Gas Monitors

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Manual for Fire Suppression & Methane Detection System

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

PortaSens ll G AS DETECTOR

Intersection Preassembled 19-inch Rack

SLIM LINE FUME HOOD MONITOR

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

Advantium 2 Plus Alarm

How To Use A Ds340 (Dsp)

HMI display Installation Guide

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

Carbon Monoxide (CO) Gas Detection and Control System

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Duct Humidity Transmitter

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Installation Instructions. Wireless Adapter/Repeater. Introduction Rev C

EX-5175-EC Sensor/Transmitter Manual

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

EC-F2 Sensors. for Cl2, ClO2, CO, H2, H2S, NH3, and NO2. Instruction and Installation Manual SENSOR

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

FIRERAY 2000 Installation Guide

Electronic Control Devices The European Product Catalogue 2007

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

ALTAIR 5X Multigas Detector Bid Specification

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Y7230A CO 2 Alarm System

ENMET Corporation PO Box 979 Ann Arbor, MI ENG 97D STAND-ALONE MANUAL. Manual Part Number MCN-389, 01/21/08

INSTALLATION INSTRUCTIONS

Cross-beam scanning system to detect slim objects. 100 mm in

MERIDIAN UNIVERSAL GAS DETECTOR TECHNICAL DATA PACKAGE

LIEBERT VNSA Installation Sheet

RECON-4 Portable Multi-gas Detector Software Manual

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Electronic Control Devices The European Product Catalogue 2007

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

PIEZOMETER AIRFLOW MEASURING RING

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert AC4. User Manual

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Analytical Instruments Smart Analyzer 90 Type SMA

EXPLORER 4 MULTIPOINT

MCR1900 Media Converter 19-Slot Chassis

SECTION ZONED (DC LOOP) FIREALARM SYSTEM

SMART SENSOR COLLECTION

CO2 Alarm. Operation. Application

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS

WIRELESS READER INTERFACE - INDOOR

The Ambient Air Monitoring System

Compliant Healthcare Technologies, LLC. NFPA 99, 2012 Changes" November 13, 2013!

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

Operation & Maintenance Manual. Electrochemical (EC) Gas Sensor Family

TS93 EMR T/PT/TDE. Surface applied door closer

Technical Specification. Generating Set with Waukesha engine burning natural gas

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

IMPACT ALARM SYSTEM FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS INTRODUCTION

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

How To Wire Wireline Cable To A Cell Phone (New Zealand)

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

FX07 Field Controller

CAUTION OPC-LM1-ID. Option Card for Frequency Divider. Fuji Electric FA Components & Systems Co., Ltd. Instruction Manual

Combustible Gas Transmitter RK-05

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

Model 201 Wiegand Touchpad Reader Installation Guide

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

Residential & Commercial Alarm Systems by Gross Security, LLC

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Engineering Specifications XNX Universal Transmitter

Installation, operation and maintenance manual TX 35A

Water Leak Detection System

RAEGuard EC FGM-13XX

T7079A,B Solid State Remote Temperature Controllers

FX07 Field Controller

SECTION NOx, CO AND NATURAL GAS DETECTION, MONITORING AND ALARM CONTROL SYSTEMS

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

OPERATING INSTRUCTIONS

EzFlex Combustible Gas Leak Detector Model EZ40

THERMAL MANAGEMENT SOLUTIONS

Transcription:

E 3 Point PRODUCT SUBMITTAL Toxic and Combustible Gas Detector Network Platform (BACnet MS-TP, Modbus) ORDERING INFORMATION Single-Gas, Surface-Mount Base unit only; sensor cartridge sold separately E3SM E 3 Point, Surface-mount, Modbus/BACnet Selectable, 24Vac/dc, -40 to 50ºC (-40 to 122ºF) Duct Mount E3DM E 3 Point, Duct-mount, Modbus/BACnet Selectable, 24Vac/dc, -40 to 50ºC (-40 to 122ºF) Sensor Cartridges E3SCO E3NO2 E3H2S E3H2 E302 E3M E3P CO Cartridge -20 to 50ºC (-4 to 122ºF), Carbon Monoxide NO2 Cartridge -40 to 50ºC (-40 to 122ºF), Nitrogen Dioxide H2S Cartridge -40 to 50ºC (-40 to 122ºF), Hydrogen Sulfide H2 Cartridge -40 to 50ºC (-40 to 122ºF), Hydrogen O2 Cartridge -40 to 50ºC (-40 to 122ºF), Oxygen CH4 Cartridge -40 to 50ºC (-40 to 122ºF), Methane C3H8 Cartridge -40 to 50ºC (-40 to 122ºF), Propane EXAMPLES OF HOW TO ORDER To order a network version, surface-mount, Modbus, H2S detector, -40 to 50ºC (-40 to 122ºF): Order E3SM + E3H2S To order a network version, duct-mount, BACnet MS-TP, NO2 detector, -40 to 50ºC (-40 to 122ºF): Order E3DM + E3NO2

SPECIFICATIONS General Specifications Uses Wall or duct-mounted, BAS or controller networkable gas detector for monitoring carbon monoxide (CO), nitrogen dioxide (NO2), hydrogen sulfide (H2S), oxygen (O2), methane (CH4), hydrogen (H2) and propane (C3H8. Size 20.56 x 14.90 x 6.72cm (8.09 x 5.87 x 2.65 ) (H x W x D) Power Requirement Relay Output Communications Operating Environment Operating Temperature Display Visual Indicators Audible Alarm Accuracy 24 Vac nominal (17-27Vac), 50/60 Hz, 0.35A; 24 Vdc nominal (20-38Vdc) 1 DPDT relay, 5A @ 250Vac; 5A @ 30Vdc RS485 Modbus; BACnet MS-TP master Commercial, Indoor, Extreme Temperature Environments H2S, NO2, O2, C H4, H2, C3H8: -40 to 50ºC (-40 to 122ºF) CO: -20 to 50ºC (-4 to 122ºF); future available CO version: -40 to 50ºC (-40 to 122ºF) 8 character, 2 line backlit LCD Green LED: Power Amber LED 1: Alarm/Fault Amber LED 2: Alarm/Fault >85 dba at 3 m (10 ft) +/- 3% of full scale @ 25C Gases Detected, Detection Ranges and Alarm Levels Gas Resolution Range Alarm A Alarm B Alarm C CO (Carbon monoxide) 1 ppm 0-250 ppm 25 ppm 200 ppm 225 ppm H 2 S (Hydrogen sulfide) 0.1 ppm 0-50 ppm 10 ppm 15 ppm 20 ppm NO 2 (Nitrogen dioxide) 0.1 ppm 0-10 ppm 0.7 ppm 2 ppm 9 ppm O 2 (Oxygen) 0.1% vol. 0-25% vol. 19.5% vol. 22% vol. 22.5% vol. H 2 (Hydrogen) 0.5% LEL 0-100% LEL 25% LEL 50% LEL 90% LEL CH 4 (Methane) 0.5% LEL 0-100% LEL 25% LEL 50% LEL 90% LEL C 3 H 8 (Propane) 0.5% LEL 0-100% LEL 25% LEL 50% LEL 90% LEL Enclosure Polycarbonate Certification CSA C22.2 No. 61010-1, UL 61010-1; FCC part 15; ICES-003 issue 4 2015 Honeywell International Inc.

Wall Mounting Mounting is usually done on concrete walls or columns, but the unit can be mounted on any vertical surface. The housing is designed with spacers on the back to allow moisture to flow behind the housing without affecting the unit. Mounting holes are located inside the housing. Open the unit to access mounting holes. Drill and mark the holes, as shown: - Width 11.1 cm (4 3/8 ) apart (if mounting directly to wall) - Height 8.3 cm (3.281 ) for electrical boxes Figure 1. Unit Dimensions Pre-drill mounting holes from the back of the unit as needed. Securely mount the unit using the appropriate screws and anchors. The unit is designed to use #6 screws. Tighten to 8.7 in-lb (1 Nm) maximum. Close the unit cover and tighten screws to 29.7 in-lb (3 Nm). Do not remove PC board when removing knockouts. Knockout on back is not for conduit entry. General Mounting Considerations: Must be easily accessible for calibration and maintenance. Mount the sensor close to the potential leak source for fastest possible leak detection. If personnel protection is the primary application, mount in the breathing zone (1 1.5m from the ground, within the range of a person s respiration area). Protect the sensor from water, excessive humidity, and washdown. Take air movement and ventilation patterns into account. To prevent electrical interference, keep sensor and wire runs away from mercury vapor lights, variable speed drives, and radio repeaters. Protect the sensor from physical damage (fork lifts, etc.). Do not mount the sensor over a door in a refrigerated area. For highly critical locations, more than one sensor should be installed in each room. Very Important: Never mount the sensor flat on a ceiling. Never mount the sensor on a vibrating surface.

Duct Mounting Special Duct Mount Installation This option works best for airflows between 500 4000 ft./min. The E3Point must be duct mounted using the custom box provided with the duct mount version. All of the components housed within the box are factory assembled. Figure 2. Duct Mounting 1. Select the location for the unit. 2. Measure and mark the holes for intake and exhaust tubes. 3. Drill the holes for the sampling tubes (making sure holes are large enough for plug). 4. Affix intake and exhaust tubes to the mounting box. 5. Insert the tubes into the holes on the ducting. 6. Screw the mounting box onto the duct. 7. Remove the desired knock out (depending on where cables will enter box) and affix appropriate conduit. 8. Run wiring through the conduit and duct mount box to the unit. Connect wires according to the Wiring Details. 9. Screw cover onto the E3Point and replace the cover on the mounting box. Ensure to orient the air holes on the air intake tube to face the airflow. Wiring Guidelines Electrical wiring must comply with all applicable codes. Operating conditions and site equipment that may be involved should be discussed with local operating personnel to determine if any special needs should be considered. Ground the shield at the main control panel. Connect the shield wire in the sensor terminal block labeled shield. Tape all exposed shield wire at the sensor to insulate it from the enclosure. Electrical Power: 24 VDC/VAC nominal, 0.35 amp maximum. Either AC or DC may be connected to the terminal block. Output: Circuit board mounted sensor provides a linear 4-20 ma output. Monitoring equipment may have a maximum impedance of 500 ohms. Wire: Signal wiring should be done with #20-24 AWG shielded twisted pair cable Belden 9841 or similar. Network units should have no more than 2,000 ft (600 m) of #22 AWG wire. Smaller gauge sizes are limited by the same resistance limit. Power wiring should be sized by local codes, but never less than #20 AWG. 120 VAC wiring should be #14 or #12 AWG.

Wiring Diagrams Circuit Board Connections Connect the power wiring to terminal J1 Connect Communication wiring to terminal J2 Connect external device (ventilator, strobe, etc.) to relay terminal J5 Main Circuit Board Connections Figure 3. Main Circuit Board Connections