MERIDIAN UNIVERSAL GAS DETECTOR TECHNICAL DATA PACKAGE
|
|
|
- Philip Cameron
- 9 years ago
- Views:
Transcription
1 MERIDIAN UNIVERSAL GAS DETECTOR TECHNICAL DATA PACKAGE
2 Table of Contents 1 Meridian Overview 2 Meridian Specifications 4 Supported Gases 5 Multi Sensor Configurations 6 Technical Drawings 16 Accessories
3 MERIDIAN OVERVIEW TRUE UNIVERSAL PLATFORM Single Transmitter for Combustible and Toxic Applications Single Sensor Interface Plug & Play Design Single User Interface Common Accessories & Installation Process Compatible with industry standard Gateways and Controllers ADVANCEMENTS IN SENSOR TECHNOLOGY Electrochemical, Infrared, Catalytic Bead and Solid State Sensors Scott Rock Solid Sensor Technology All sensors can be replaced under power in hazardous locations Electrochemical sensors offer support for multiple ranges with one sensor Calibration of electrochemical sensors is range invariant MULTIPLE COMMUNICATION PROTOCOLS 420 ma, Modbus are standard Wired HART (option) Wireless HART, ISA100.11A (options) GLOBAL APPROVALS Designed to the highest international standards for global use SIL2 certified by TUVRheinland 1
4 MERIDIAN SPECIFICATIONS Certifications Global Approvals Area Classification IECEx, C CSA US, ATEX, INMETRO, EURASIAN CUSTOMS UNION, CHINA EX, CCCF, RCM, FCC, INDUSTRY CANADA, CE, ANATEL, MARINE DIRECTIVE SHIP S WHEEL, ABS SIL2 (Third Party Certification by TUVRheinland) Class I Div. 1 Group ABCD, Class II Div. 1 Group EFG, Class III Equipment Group I/II, Zone 0/20 & Zone 1/21, IIC Environmental Operating Temperature 40 to 167 Fahrenheit / 40 to 75 Celsius Humidity 595% RH (non condensing) Storage Temperature 67 to 167 Fahrenheit / 55 to 75 Celsius Transmitter Specification Power 2 wire, 3 wire, 4 wire Operating Voltage 3/4 Wire 1030 VDC (24 VDC nominal) Operating Voltage 2 Wire 1830 VDC (24 VDC nominal) Power Consumption Watts based on sensor configuration Add 2.6 Watts to any configuration if heated display is used Enclosure Material Copper Free Aluminum 316 Stainless Steel Enclosure Ingress Protection NEMA 4X, IP66 Conduit Connections 3/4 NPT (M20 thread adapter available) Communication Protocols Maximum 420 loop load Ohms (@24 VDC) Alarms Standard: 420 ma, Modbus Optional: HART, Wireless HART, ISA100.11A 840 Ohms non isolated current source 680 Ohms current sink 3 programmable alarms with set and reset (adjustable deadband); 1 fail safe system fault Relays 4 Form C relays, rated 5 Amp at 30 VDC/240 VAC, resistive loads Display Graphical LCD display visible in bright sunlight; Display indicates Sensor Name, Gas Name, Full Scale of Range, Gas Concentration, Fault, Alarm Status, Trend Graph WITH selectable time scale showing current reading, set points and full scale. Display provides simple, intuitive calibration instructions and guides user through the calibration process. Languages English, Portuguese, French, Spanish, Chinese, Russian 2
5 User Configuration Control Transmitter GUI, HART handheld Communicator, Modbus Access Control Memory Accessories Flexible Design Transmitter provides controlled access to sensor range, alarm settings and other safety functions; password protection for secure configuration control Nonvolatile memory ensures configuration parameters are retained in the event of power loss Rain shield/deluge Guard, Flow Cell, Calibration Adapter, Duct Mount Kit, Sun Shield, Universal Mounting Adapter Plate Flexible design allows for ease of calibration without the need to remove instrument components Weight 6.5 lbs/3 kg (Aluminum enclosure) 11 lbs/5 kg (Stainless Steel enclosure) Wiring Transmitter accept industry standard 2wire, 3wire, or 4wire inputs Flexible Mounting Option Mounting Flange Surface Area Mounting Bolt Holes Transmitter provides multiple conduit entry points for sensor, power, signal, and relay wiring 6.50 x5.78 / 165mm x 147mm (Aluminum Enclosure) 7.00 x5.25 / 178mm x 133mm (Stainless Steel Enclosure) 4.72 x4.92 / 120mm x 125mm (Aluminum Junction Box Enclosure) Diametrically opposed 5.85 ; / 149mm; 8mm holes (Aluminum Enclosure); Diametrically opposed 6.25 ; / 159mm; 8mm holes (Stainless Steel Enclosure); Diametrically opposed on 45 angle, 4.5 ; / 114mm; 8mm holes (Aluminum Junction Box) Pipe Threads 3/4 NPT (M20 thread adapter available) Sensor Specification Universal Detector Head Detector head accepts all sensor types Sensor Types Combustible: Catalytic Bead, Infrared Electrochemical: Standard and Scott Rock Solid sensors Solid State: Metal Oxide Semiconductor (MOS) Number of Sensors Supports up to 3 sensors per transmitter Sensor Replaceable Under Power Sensors can be replaced under power without declassifying the area Automatic Sensor Voltage Adjustment Sensor voltage is automatically detected and adjusted by the transmitter during installation Simple Plug & Play Sensor Install Plug and play design allows for one hand sensor installation Remote Calibration User Selectable Range Sensor can be bench calibrated and then installed in field without additional recalibration on site; Available Duct Mount calibration kit makes it easy to perform calibration on remote transmitter installations that are difficult to access Sensor offers multiple sensor ranges allowing user to select the specific range for their application requirements without the need to recalibrate the sensor Range Invariant Calibration Sensor range can be changed without recalibration Sensor Refurbishment Environment Friendly Smart sensor electronics and snap fit housing makes it possible to refurbish sensor at the end of its useful life Environment friendly sensor design allows for reuse of sensor electronics and housing with simple kernel replacement 3
6 SUPPORTED GASES FULL RANGE OF COMBUSTIBLE AND TOXIC GASES COMBUSTIBLE Gas Type Range TOXIC Gas Type Range Acetone Ammonia 50, 100, ppm Benzene Arsine 500, 1000 ppb Butadiene Boron Trichloride 10 ppm Butane Boron Trifluoride 5, 15 ppm Ethane Bromine 1, 10 ppm Ethanol Carbon Dioxide 05% v/v Ethylene Carbon Monoxide 50, 100, 150, 500, 1000 ppm Hexane Chlorine 1, 3, 5, 10, 20, 30 ppm Hydrogen Chlorine Dioxide 1, 3, 5 ppm Isobutanol Diborane 1 ppm, 5 ppm Isopropyl Alcohol Fluorine 1, 3, 5, 10, 25 ppm Methane Germane 1000 ppb Methanol Hydrogen 1, 4% v/v Methyl Ethyl Ketone (MEK) Hydrogen Bromide 1, 5, 10, 30 ppm Pentane Hydrogen Chloride 1, 10, 25, 50, 100 ppm Propane Hydrogen Cyanide 10, 25, 100 ppm Propylene Hydrogen Fluoride 1, 5, 10, 30, 100 ppm Toluene Hydrogen Sulfide 10, 25, 50, 100, 200 ppm Xylene Methanol 500 ppm Methyl Mercaptan 3, 10 ppm Methyl Iodide 25 ppm Nitric Oxide 50 ppm Nitrogen Dioxide 10, 20 ppm Oxygen 10, 25% v/v Ozone 1, 3 ppm Phosphine 500, 1000 ppb Silane 1 ppm, 10 ppm Silicon Tetrafluoride 5 ppm Sulfur Dioxide 1, 3, 10, 25, 50, 100, 500 ppm TEOS 50 ppm Tungsten Hexafluoride 1, 3 ppm 4
7 MULTI SENSOR CONFIGURATIONS MERIDIAN UNIVERSAL GAS DETECTOR MERIDIAN UNIVERSAL GAS DETECTOR CAN SUPPORT UP TO 3 SENSORS MERIDIAN 3/4 WIRE TRANSMITTER ALLOWED SENSOR COMBINATIONS (USE ONLY WITH IS BARRIER ASSEMBLY ) Sensor #1 Sensor #2 Sensor #3 ECHEM* ECHEM * ECHEM * O2 ( ) COMBUSTIBLE CAT BEAD ( ) MOS ( ) IR CO2 ( ) COMBUSTIBLE IR ( ) O2 ** ECHEM * O2 ** O2 ** ECHEM * ECHEM * O2 ** ECHEM * O2 ** O2 ** ECHEM * ECHEM * O2 ** ECHEM * O2 ** O2 ** ECHEM * ECHEM * O2 ** ECHEM * O2 ** O2 ** O2 ** O2 ** : Not available in order to meet intrinsic safety requirements. * ECHEM SENSOR PART NUMBERS THRU , THRU , AND SENSOR SIMULATOR ** OXYGEN SENSOR PART NUMBER Junction box integral to transmitter (included with multiple sensor configuration) 2. Junction box for remote detector (sold separately) 5
8 TECHNICAL DRAWINGS MERIDIAN TRANSMITTER ASSEMBLY MERIDIAN TRANSMITTER ASSY. ITEM N O QTY PART N O DESCRIPTION WIRE POWER SUPPLY PCB 2WIRE POWER SUPPLY PCB TERMINAL/RELAY MODBUS RS485 PCB (STANDARD WITH 34 TRANSMITTER) M4 X 85 STANDOFF 34 WIRE I.S. BARRIER ASSY 2WIRE I.S. BARRIER ASSY TERMINAL BLOCK COVER HOUSING ORING LCD DISPLAY ASSEMBLY LCD DISPLAY ASSEMBLY WITH HEATER BLIND DISPLAY ASSEMBLY x 3/4 PHILLIPS PAN HEAD 6
9 TECHNICAL DRAWINGS WALL MOUNTING OPTION 7
10 TECHNICAL DRAWINGS WALL MOUNTING OPTION UNIVERSAL MOUNTING ADAPTER PLATE ( ) 8
11 TECHNICAL DRAWINGS DUCT MOUNTING OPTION DUCT MOUNT ADAPTER KIT ( ) ( ) 9
12 TECHNICAL DRAWINGS TRANSMITTER AND JUNCTION BOX ASSEMBLY 10
13 TECHNICAL DRAWINGS 11
14 ACCESSORIES MERIDIAN UNIVERSAL GAS DETECTOR CALIBRATION ADAPTER SKU: FLOW CELL ADAPTER SKU: DUCT MOUNT ADAPTER SKU: DELUGE GUARD SKU: JUNCTION BOX SKU: SUNSHIELD SKU: UNIVERSAL ADAPTER PLATE SKU: STAINLESS STEEL END CAP SKU: NPT/ NPT GLAND FITTING SKU: SENSOR SIMULATOR SKU:
15 NOTES MERIDIAN UNIVERSAL GAS DETECTOR 17
16 At Scott, we ve been developing ways to protect people since Our founder, Earl Scott, began the company by tinkering with inventions in his basement in Lancaster, NY. Since that time, the Scott name has stood for unquestioned quality when safety is critical. Facilities across hundreds of industries rely on Scott s attention to detail, failsafe measures, attentive service and constant innovation. The Meridian universal gas detector is another offering in our long, proud history of safety equipment Scott Safety. SCOTT, the SCOTT SAFETY Logo, Scott Health and Safety, Meridian Universal Gas Detector, and Rock Solid are registered and/or unregistered marks of Scott Technologies, Inc. or its affiliates. Monroe Corporate Center P.O. Box 569 Monroe, NC Telephone: Facsimile: [email protected] H/S 7153A_EN 12/13 ISO 9001 Registered. All rights reserved.
P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification
P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification 1.0 This specification details the attributes and operating characteristics of the MSA Ultima X Series sensors/transmitters.
Ultima X Series Gas Monitors
Ultima X Series Gas Monitors For continuous monitoring of oxygen, toxics, and combustible gases Now with SIL 2 Certified Products MSA s Ultima X Series Gas Monitors are microprocessor-based transmitters
Engineering Specifications XNX Universal Transmitter
Engineering Specifications XNX Universal Transmitter 1.0 General Description: The XNX Universal Transmitter is a comprehensive solution designed to operate in hazardous locations and utilize sensor technologies
Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors
Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors www.static-control.in 1 Introduction The detection or monitoring of flue gases and or hazardous gases has been a complex subject
PortaSens ll G AS DETECTOR
PortaSens ll G AS DETECTOR ONE DETECTOR... FOR MANY GASES! Sensors can be exchanged quickly and easily without the need for calibration. Sensors are maintained in ready condition in the optional sensor
Operation & Maintenance Manual. Electrochemical (EC) Gas Sensor Family
Operation & Maintenance Manual Electrochemical (EC) Gas Sensor Family For Detection of Oxygen and Toxic Gases Important: Read and understand contents prior to first use. Improper use or operation could
Single-Gas Detector. Long-term solution. h Class I, Div. 1, Gr. A, B, C, D 4 5062-26-NCL-EN
Single-Gas Detector H 2 S, CO, O 2, SO 2, NH 3, PH 3, Cl 2, ClO 2, NO, NO 2, HCN, ETO, O 3 Long-term solution Compact and affordable, the GasAlert Extreme reliably monitors for any single gas hazard within
Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure
QUADSCAN II SERIES 7400 ONE TO FOUR CHANNEL RECEIVER QUADSCAN II SERIES 7400 ONE TO FOUR CHANNEL RECEIVER Centralizes Monitoring and Alarming for Gas Transmitters and Fire Detectors. The QuadScan II receiver
Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000
IMR 5000 Continuous Flue Gas Monitoring System The IMR 5000 is state-of-the-art continuous flue-gas monitoring system, and is designed for a wide variety of flue-gas monitoring applications. The IMR 5000
SEC 1500 Gas Detector Instruction Manual
SEC 1500 Gas Detector Instruction Manual 1 I. SPECIFICATIONS Table of Contents II. III. IV. GENERAL DESCRIPTION DETAILED DESCRIPTION Enclosure Controls and Indicators Calibration/Reset/Date Switch Optional
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
ALTAIR 5X Multigas Detector Bid Specification
ALTAIR 5X Multigas Detector Bid Specification PHYSICAL CHARACTERISTICS Gas delivery Size, pumped unit without IR Size, pumped unit with IR Size, pumped unit with PID Weight Handling Case material Environmental
sierra monitor corporation Fire and Gas Detection Systems
sierra monitor corporation Fire and Gas Detection Systems Sierra Monitor Corporation Inspired by technology, driven by safety, designed with passion Information Technology protecting life and property
ENMET Corporation PO Box 979 Ann Arbor, MI 48106-0979 ENG 97D STAND-ALONE MANUAL. Manual Part Number 80003-035 MCN-389, 01/21/08
PO Box 979 Ann Arbor, MI 48106-0979 ENG 97D STAND-ALONE MANUAL Manual Part Number 80003-035 MCN-389, 01/21/08 Table of Contents 1.0 Introduction...1 1.1 Unpack...1 1.2 Check Order...1 1.3 Serial Numbers...1
Lockout Specification BW Clip Maintenance-free single gas detector
Lockout Specification BW Clip Maintenance-free single gas detector The gas detector must satisfy the following. Physical Specifications Size (d x w x h ) Physical detector size shall be no larger than
Fire Alarm System Accessories
Approved by APPROVED Fire Alarm System Accessories FM Approved* Intrinsically Safe Devices Single and Dual Channel Isolated Barrier Modules Features Single or dual channel intrinsically safe, transformer
An easy and flexible way to do gas detection.
An easy and flexible way to do gas detection. 24 Plug-and-Play fieldreplaceable sensors including PID and Infrared options Up to 6 gases monitored simultaneously Optional integral sampling pump with strong
3500/93 System Display
3500/93 System Display Bently Nevada* Asset Condition Monitoring Description The 3500/93 System Display is designed to meet the requirements of American Petroleum Institute (API) Standard 670 and provide
Application Requirement
Hazardous Gas Monitors Sensor Selection Overview Safety Monitoring (LEL) Toxic Limit Detection (PEL) Leak Detection Personal Safety Application Requirement Exposure Assessment (TWA) Ambient Air Quality
Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.
Pump_PT580 Optional PT580-CFG PCM370 Optional DTM96 Buffered Dual Relay Remote Reset Local Display Condition Monitoring System PLC/DCS PT580 Digital Vibration Switch Introduction The PT580 Digital Vibration
EXPLORER 4 MULTIPOINT
EXPLORER 4 MULTIPOINT Sampling gas analyser EXPLORER 4 MULTIPOINT is a sampling gas analyser, with 4 gas detection sensors ( LEL,H2S, O2 CO ) reliable and in accordance of the Rules with 15 sampling points
PolyGard Carbon Monoxide CO Transmitter ADTX3 1110
PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 DESCRIPTION CO transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air
Hazard Warning Signage Guidelines
Fire Department 401 Oak Street, #402 Roseville, California 95678-2649 Hazard Warning Signage Guidelines Where hazardous materials are stored in quantities that require a permit pursuant to CFC Table 105.6.20,
ABSTRACT INTRODUCTION
Infrared Technology for Fail-To-Safe Hydrocarbon Gas Detection Authors: Dr. Shankar Baliga is Manager of Research & Development at General Monitors. He has a Ph.D. in Physics from Ohio State University
FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)
FLARE MONITORS Infrared Sensors for Monitoring Smokeless Flares, Pilots, and Flame Intensity FMDS2014 FLARE MONITOR (FM) Monitor smokeless flare combustion efficiency to maximize destruction of hazardous
The Ambient Air Monitoring System
The Ambient Air Monitoring System 1.0 Introduction: The Ambient Air Monitoring System (AAMS) can measure a range of toxic and flammable gases, particulate matter, meteorological and environmental parameters
DrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors
DrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors Faster response higher accuracy greater stability longer life. Dräger electrochemical sensors offer all these benefits. The robust
Toxic Inhalation Hazard (TIH) Commodity List (AAR 2.3, 6.1, and Anhydrous Ammonia) Carloads, 2003 Waybill Sample
Toxic Inhalation Hazard (TIH) Commodity List (AAR 2.3, 6.1, and Anhydrous Ammonia) Carloads, 2003 Waybill Sample Commodity HazMat STCC Commercial STCC WASTE ALLYL ALCOHOL 4821019 WASTE TOXIC LIQUID, CORROSIVE,
Series B14 Monitor System
Series B14 Monitor System Home Office European Office Analytical Technology, Inc. ATI (UK) Limited 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park Collegeville, PA 19426 Delph New Road, Delph Saddleworth
Draeger-Tubes and accuro Pump
Draeger-Tubes and accuro Pump Trusted Technology that s ahead of its time Accurate Easy to read Flexible Fast Specific Easy to use Maintenance free Multi-Gas Detector accuro pump One handed operation What
INCOMPATIBILITY OF COMMON LABORATORY CHEMICALS
INCOMPATIBILITY OF COMMON LABORATORY CHEMICALS When certain hazardous chemicals are stored or mixed together, violent reactions may occur because the chemicals are unsuitable for mixing, or are incompatible.
3DLevelScanner II TECHNICAL DATA SHEET
TECHNICAL DATA SHEET Changing the market from level to volume APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
Thermatel Model TA1 Mass Flow Transmitter
Thermatel Model TA1 Mass Flow Transmitter D E S C R I P T I O N Thermatel Thermal Mass Flow Transmitter, Model TA1, provides a high level of performance in mass flow measurement of air and gases. Powerful
Balancing chemical reaction equations (stoichiometry)
Balancing chemical reaction equations (stoichiometry) This worksheet and all related files are licensed under the Creative Commons Attribution License, version 1.0. To view a copy of this license, visit
Sieger Searchpoint Optima Plus
Sieger Searchpoint Optima Plus Advanced infrared point gas detector Sieger Searchpoint Optima Plus Why Searchpoint Optima Plus is the right choice... The proven strengths of the original Searchpoint OPTIMA
Electronic, Digital and Mechanical Vibration Switches
PT500 Electro-Mechanical Vibration Switch Introduction The PT500 is an economical solution that provides basic vibration protection for rotating reciprocating machines. The PT500 uses an inertia sensitive
Microcor Wireless Transmitter (MWT)
Rohrback Cosasco Systems, Inc. Microcor Wireless Transmitter (MWT) Features: Highly Secure and Reliable Self Organizing Wireless Mesh Network High Resolution Metal Loss Measurement for all process environments
Thermal Mass Flow Meter (Series MST)
Overview MaxiFlo TM MST series Thermal Mass Flow Meter is the instrument of choice for reliable and accurate measurement of mass flows for various gases. It measures the mass flow of gas based on constant
Technical Information RIA14
TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical
CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter
CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter Product Bulletin CD-Pxx-00-1 Code No. LIT-216525 Issued December 6, 2010 Supersedes September 12, 2008 Johnson Controls offers a complete line of Carbon Dioxide
How Sensors Work. How Oxygen, Electrochemical Toxic, and Metal Oxide Semiconductor Sensors Work *
How Oxygen, Electrochemical Toxic, and Metal Oxide Semiconductor Sensors Work * 1. Oxygen sensor detection principle Most portable or survey instruments used for workplace evaluation of oxygen concentrations
Triple Waveband Infra-Red Flame Detection
Minerva S200PLUS Ex ia Intrinsically Safe & Ex d Flameproof Solar Blind Flame Detectors Triple Waveband Infra-Red Flame Detection Key Features Unrivalled black body rejection over a wide range of source
Automotive Air Quality Sensors: industrial innovations to protect people s health
Pioneering sensor and detector technology Automotive Air Quality Sensors: industrial innovations to protect people s health COST Action TD1105 3 rd Management Committee Meeting Barcelona, Spain, 21st June
Analytical Instruments Smart Analyzer 90 Type SMA
Data Sheet Analytical Instruments Smart Analyzer 90 Type SMA Oxygen Only or Optional Oxygen and Combustibles Rugged Industrial Design Easy Installation and Start-up Highly Accurate Sensors Simplified In-house
IMVIB. Online vibration monitoring for Ariel compressors
IMVIB Online vibration monitoring for Ariel compressors The cost-effective way to add spectral vibration measurement & trending on critical machinery Monitoring vibration trends of your industrial equipment
AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products
Data sheet DS/AT500-EN Rev. M AT500 Magnetostrictive Level Transmitter Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Features Mounts from Top of Tank High Resolution
Sanitary Type Electronic Flow Switches
Industries Pharmaceutical Sanitary Type Electronic Flow Switches Food and Beverage Biotechnology Semiconductor Water Treatment S Series Ameritrol, Inc. Instruments and Controls Features No Moving Parts
Buckeye Detection Systems Fixed Detection Systems Application Survey
Buckeye Detection Systems Fixed Detection Systems Application Survey Channel Partner Representative : Company Name: Representative: BDS Representative: Client Contact Information : Company Name: Company
RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
Dräger Polytron SE Ex Fixed Gas Detector
Dräger Polytron SE Ex Fixed Gas Detector The Dräger Polytron SE Ex... DD sensing heads are gas detectors for the continuous monitoring of flammable gases and vapors in the ambient air. The measurement
Detcon Model Series 700
Detcon Model Series 700 GAS DETECTORS Catalog #700-0814 Removing the Environmental Equation from your Gas Detection Decisions 316 SS Construction Encapsulated Electronics Water-Proof Vibration-Proof Corrosion-Proof
Electronic Flow Switches
Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.
GE Measurement & Control Solutions Sentinel LCT Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement Benefits Extremely reliable and highly accurate flowmeter, designed specifically
EX-5175-EC Sensor/Transmitter Manual
PO Box 979 Ann Arbor, MI 48106-0979 www.enmet.com EX-5175-EC Sensor/Transmitter Manual Manual Part Number 80003-099 MCN-13-008, 11/06/13 Table of Contents 1.0 INTRODUCTION... 1 1.1 Unpack... 1 1.2 Check
Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370
Pump_TM016 Pump Local Display TM0200 TM0200 4-20mA PLC/DCS Case 1 Pump Relay Output Module 4-20mA Optional PT371 Modbus PT373 Case 2 PCM370 TM016 Velocity/ Acceleration Vibration Transmitter Introduction
MSA Fixed Gas & Flame Detection for the Oil, Gas & Petrochemical Industries
MSA Fixed Gas & Flame Detection for the Oil, Gas & Petrochemical Industries A Passion for Safety Oil, gas and petrochemical industries and corresponding potentially hazardous and combustible materials
A99B Series Temperature Sensors
FANs 125, 121, 930, 930.5 Product/Technical Bulletin A99 Issue Date 0615 A99B Series Temperature s The A99B Series Temperature s are passive PTC (Positive Temperature Coefficient) sensors. The A99B sensors
In-Line Electronic Flow Switches
In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
SECTION 23 90 13 NOx, CO AND NATURAL GAS DETECTION, MONITORING AND ALARM CONTROL SYSTEMS
SECTION 23 90 13 NOx, CO AND NATURAL GAS DETECTION, MONITORING AND ALARM CONTROL SYSTEMS PART 1 - GENERAL 1.01 Section Includes A. Requirements for provision of the Natural Gas (CH4), Carbon Monoxide (CO)
COMBUSTIBLE GAS AND HC REFRIGERANT LEAK DETECTOR OPERATING INSTRUCTIONS DETECTS ALL HYDROCARBON & OTHER COMBUSTIBLE GASES JB INDUSTRIES
LDC-4000 COMBUSTIBLE GAS AND HC REFRIGERANT LEAK DETECTOR OPERATING INSTRUCTIONS DETECTS ALL HYDROCARBON & OTHER COMBUSTIBLE GASES WWW.JBIND.COM 800.323.0811 [email protected] TABLE OF CONTENTS LDC-4000
HMI display Installation Guide
HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC
Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)
Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow) Drawing 8c Drawing 9c U391_TA10C_DoP_e_150421 www.hoentzsch.com 1 of 5 Measured
APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement
For Gauge And Absolute Pressure Measurement Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy Alternate
Regards from the Team at Rheology Solutions.
Rheology Solutions is the sole Australian distributor of this product range and we welcome the opportunity of discussing your application requirements. We hope the information you are seeking is contained
Regulator Options and Accessories
Regulator Options and Accessories Regulator accessories are available separately or mounted on Swagelok regulators. Some accessories limit regulator pressure or temperature ratings. Additional materials,
www.klmtechgroup.com TABLE OF CONTENT
Page : 1 of 13 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia TABLE OF CONTENT SCOPE 2 REFERENCES
Hazardous Area Classifications and Protections
Hazardous Area Classifications Product Bulletin Hazardous Area Classifications and Protections The intent of this document is to provide a broad overview of hazardous area classifications and the types
Scraper Passage Indicator. Electrical Indicator. Features
IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage
Liquid Flow Conversions
Liquid Flow Conversions This bulletin provides valuable information for converting liquid flows from water to other liquids. This is extremely useful because many valves are tested and catalogued in water
Terminal Boxes Series 8146
Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm
Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA
Mobrey Ultrasonic MSP900SH Level and MSP900FH Flow Transmitters Product Data Sheet February 2015 IP2032, Rev BA Non-contacting measurement with no moving parts Fast and simple to install and configure
713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.
and Transmitter All-in-one package for open channel flow measurement. 3.1 NEW Class 1, Division 1 Approved Sensor As our products are continuously improved, we reserve the right to make any change in the
Explosion proof enclosures
1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without
EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL
PRODUCT NAME: CP/PB -150- EXPLOSION-PROOF-MANUAL CALL POINT/ PUSH BOTTON DOC NO.: EX-TECH SAS-12-CP-PB150-TM REV01 EXPLOSION-PROOF MANUAL CALL POINT/ PUSH BOTTON II 2GD EPL Gb, Db Ex d IIC T6, IP66 Ex
How To Use An Irius Pid Detector
SIRIUS PID & 4-Gas Detector [ Compact and Versatile for all your needs] SIRIUS [ Maximum versatility in one hand] The new SIRIUS PID Detector combines incredible performance, versatility and ease of use
Technical data sheet TDS0070
Technical data sheet TDS0070 ATEX Certified II 2 G Ex d IIC T4 Gb IECEx Certified Ex d IIC T4 Gb Ta = -20ºC to +60ºC FEATURES INCLUDE: - ATEX and IECEx Certified explosion proof Exd housing for Premier
Linear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
RAEGuard EC FGM-13XX
RAEGuard EC FGM-13XX User s Guide P/N 033-4102-000 Rev B May 2007 - READ BEFORE OPERATING - This manual must be carefully read by all individuals who have or will have the responsibility of using, maintaining,
TYPE 65UV5-1004 CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output
133-683 JUNE 28, 2006 TYPE 65UV5-1004 CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output DESCRIPTION APPLICATION The Fireye 65UV5-1004 flame scanner is a microprocessor based flame
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
Rosemount 751 Field Signal Indicator
Rosemount 751 Field Signal Indicator Product Data Sheet August 2014 00813-0100-4378, Rev FA Available with an LCD display or analog meter Compact, rugged, and designed for industrial environments Available
Micro Motion 3098 Gas Specific Gravity Meter
Product Data Sheet PS-001161, Rev. D April 2013 Micro Motion 3098 Gas Specific Gravity Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.
SafeSite LED RTO Area Light - UL844. for Indoor and Outdoor Industrial Applications #
SafeSite LED RTO Area Light - UL844 for Indoor and Outdoor Industrial Applications # On when it matters most. Products and solutions that protect your business 2 www.dialight.com MDTFSSWRTOX001_J Features
PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown
Self-Regulating 920 Series Dual-point heat-tracing control system Power-Limiting Mineral Insulated 920*E4FWL*SIS302*SS3102 shown Product overview The DigiTrace 920 is a compact, full-featured, microprocessor-based,
STX2100. Differential Pressure (Flow) Transmitter. GE Measurement & Control. Models FKC...5. Features
GE Measurement & Control STX2100 Differential Pressure (Flow) Transmitter Models FKC...5 The STX2100 differential pressure (flow) transmitter accurately measures differential pressure, liquid level, gauge
Technical Data Sheet. 3DLevelScanner
Changing the market from level to volume Technical Data Sheet APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual
0 P a g e H.264 Color or Day/Night SurroundVideo Installation Manual Inside the box: A. Arecont Vision SurroundVideo camera B. Mounting template C. RJ45 female to female coupler D. Hex key E. Security
HAZARDOUS AREA TECHNICAL GUIDE
Page 1 HAZARDOUS AREA TECHNICAL GUIDE The Redapt Hazardous Area Technical Guide provides an overview for the design and use of equipment used within potentially explosive atmospheres created by gases,
Liquid Leakage Sensor Amplifier
9 Liquid Leakage Sensor Amplifier Space-saving Sensor Amplifier reliably detects a wide variety of liquids ranging from water to chemical liquids with low conductivity 1 Detects leakage of liquid such
Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43
Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented
Chlorine Gas Detection System Operation & Maintenance
Chlorine Gas Detection System Operation & Maintenance Maynard King K&D Pratt Instrumentation 2011 Clean and Safe Drinking Water Workshop Chlorine Gas Detector Operation, Maintenance, Checks 1. Why you
Repeaters and Mimics Data Sheet
Repeaters and Mimics Data Sheet IDR series repeaters and mimics allow vital information from a Notifier fire system to be communicated to points around a building remote from the fire alarm control panel.
FCI ST75 Series Flow Meters
FCI ST75 Series Flow Meters Small Line, Mass Flow Meters for Industrial and Commercial Process Gases Low cost, easy installation flow measuring for 1/4 inch to 2 inch [6 mm to 51 mm] line sizes FCI ST75
Rosemount 333 HART Tri-Loop
Product Data Sheet Rosemount 333 Rosemount 333 HART Tri-Loop HART-TO-ANALOG SIGNAL CONVERTER Convert a digital HART signal into three additional analog signals Easy to configure and install Accessory product
Compressed Gas Cylinder Safety, Management and Disposal
Introduction Compressed gas cylinders are necessary in many campus operations and research. Compressed gases expose users to both chemical and physical hazards. Gases contained within compressed gas cylinders
Worcester DS/DM Series UltraSwitch Switch box
Worcester DS/DM Series UltraSwitch Switch box Features DS/DM Series Ultraswitch Description The DS/DM Series UltraSwich from Flowserve Worcester provides cost efficient, accurate and reliable position