Line-Mounted Valves L Series



Similar documents
Valves. Sub-Base Mounted Valves to ISO 5599/2

3 Port Solenoid Valve

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Electrical connection technologies Electrical connectors Electrical connectors with cable, series. Brochure

Cable Plug acc. to DIN EN , Form A

Electro-pneumatic control valves

Assisted lift operated 2/2-way solenoid valves Type EV250B

Single sub-base valve

3/2- and 2/2-way cartridge valve type BVE

type V46, solenoid or pneumatic operated

G1/4 Q8. Standard with biased position

Table of Contents. MicroAir Series...3-9

3 Port Solenoid Valve

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

zamak nitrile rubber self-extinguishing technopolymer aluminum

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2 Solenoid Cartridge Valve, Size 6

2.12. page Products for Explosion hazardous Environment

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Custom configuration such as modified angle dimensions, other flange standards, 3-way function, alternative materials.are available on request.

4/2-Way Pneumatic Solenoid Valve

System 8. ü ( System 8

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

ISO /2 (VDMA 24563) ISO 02 (18 mm) - ISO 01 (26 mm) Valves

3/2-way Solenoid Valve, direct-acting, NC or NO

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Chapter 6: Check Valves

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

400 Series Buccaneer BUCCANEER POWER. bulgin

Pneumatic Control and Shut-off Butterfly Valve Pfeiffer Type BR 14b/31a and Type BR 14c/31a

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS VS VS VS VS

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double

DSE5J /112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO (CETOP 05)

UM/ /2 or 5/3 Solenoid and air pilot actuated soft spool valves

Electro-hydraulic pressure switches type DG

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

MPPM1606 MPPM2508 MPPM3210

3/2-way Mini Solenoid Valve

Control- and feedback head for integrated mounting on Robolux valves Type 2036

SOLENOID VALVES AND PNEUMATIC VALVES

Miniature Pneumatic Solenoid Valve. Power Options: 0.5 Watt (6 psig model) 1.0 Watt (30, 100 psig model) Voltage Options: 3, 5, 12 or 24 VDC

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

zamak nitrile rubber self-extinguishing technopolymes aluminum

Type and Type Pneumatic Control Valves Type 3510 Micro-flow Valve

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

UM/ /2 & 5/3 valves, solenoid and pilot actuated ISO , ISO size 1, 2, 3 & 4 Sub-base mounted

Givare NC-SRS 280 och 880

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

SC351. Model: SC351 NIL. Part List US-English

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

On-off valves MS-EM/EE, MS series, NPT

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Solenoid Valve Island Type 3965

2/2 and 3/2 Way Size 6 Seat Valves

4 Posiflow Proportional Solenoid Valves

PRE3G /212 ED PILOT OPERATED PRESSURE CONTROL VALVE WITH PROPORTIONAL CONTROL AND INTEGRATED ELECTRONICS. Q max 40 l/min SERIES 12

Extruded Body Cylinders, ISO 6431, ISO compliant Series 62

Automated Lubrication Systems Parts & Accessories

Directory chapter 04

Digital inductive conductivity transmitter

Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors

DCS Input/Output Relay Card Series

Solenoid Valve Type 3962

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Magnetic proximity switches

MPLM1630 MPLM2535 MPLM3240

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

3/2-way pneumatic cartridge solenoid valve

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Linear Luminaire with LED Series EXLUX 6402/2

HARTING Ethernet Cabling 8-poles Overview

GROENEVELD AUTOMATIC GREASING SYSTEMS

Installation, operation and maintenance manual TX 35A

Instruction Manual. ThinkTop Basic Digital VDC PNP/NPN ESE00225EN

Digital input modules

zamak nitrile rubber selfestinguishing technopolymer aluminum B10 24 V DC (± 10%) holding 0,32 W, pick-up 5,5 W (25 ms) IP65 button with tool

SOLENOID VALVES 3-4 WAY

HERZ-Thermal Actuators

This product can be assembled to the baseplate maintaining 5 mm center-to-center spacing. Thus any number of poles can end-to-end stack.

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

New Media Power Socket Outlets. New Media Power Socket Outlets

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

Vario-Series Accessories

I.T BSV-N series 25 ELECTROMECHANICAL TURRETS TECHNICAL INFORMATION ISSUED

Transcription:

Spare Part Kit for Valve Series B1LSAD3 Line-Mounted L Series Accessories Spare Part Kits All Series Valve Series B1LSAD3 40.1609 Incl. O-rings, gaskets, spring or muffl er Spare Part Kit for Valve Series L01 Valve Function SA4 SS4 L01-K1 SS5 SS6 L01-K3 Incl. O-rings, gaskets, spring or muffl er Spare Part Kit for Valve Series L1 Valve Function BA4 PA4 L1-K1 BB4 PP4 L1-K2 BB5/6/7 PP5/6/7 L1-K3 Incl. O-rings, gaskets, spring or muffl er Spare Part Kit for Valve Series L2/S2/NA2 und NE2 Valve Function BA4 PA4 JA4 L2-K1 BB4 PP4 JJ4 L2-K2 BB5/6/7 PP5/6/7 JJ5/6/7 L2-K3 Incl. O-rings, gaskets, spring or muffl er Spare Part Kit for Valve Series L8 Valve Function EL4 40.1768 DL4 40.1882 DL5/6/7 40.1446 EM4 40.1677 DM4 40.1877 DM5/6/7 40.1468 Incl. O-rings, gaskets, spring or muffl er 519

Line-Mounted L Series Accessories Solenoids Solenoids with Plug-in Device for Female Connector to DIN EN 175301-803 (old DIN 43650) Form A Valve Series B1LSAD3 Manual Override Option approx. [kg] 24 VDC Without 0 0.500 226-867 24 VDC 24 VDC 24 VDC 24 VDC 24 V / 50-60 Hz Flush non-locking Flush locking Protruding non-locking Protruding locking Flush non-locking H 0.500 226-781 W 0.500 226-862 Y 0.500 226-947 Z 0.500 226-950 H 0.300 237-536 24 V / 50-60 Hz Flush locking W 0.300 237-760 110 V / 50-60 Hz Without 0 0.300 237-690 110 V / 50-60 Hz 110 V / 50-60 Hz 110 V / 50-60 Hz 110 V / 50-60 Hz 230 V / 50-60 Hz 230 V / 50-60 Hz 230 V / 50-60 Hz Flush non-locking Flush locking Protruding non-locking Protruding locking Flush non-locking Flush locking Protruding non-locking Protruding locking 230 V / 50-60 Hz Incl. solenoid cover, screws and gaskets H 0.300 237-534 W 0.300 237-758 Y 0.300 237-742 Z 0.300 237-744 H 0.300 237-535 W 0.300 237-759 Y 0.300 237-743 Z 0.300 237-745 Photo shows solenoid for 24 VDC without Photo shows solenoid for 110V/50-60 Hz with flush non-locking 520 www.numatics.com Pneumatic-Catalogue-GB-09/05

Line-Mounted L Series Accessories Solenoids Solenoids with Plug-in Device for Female Connector to Industrial Form, Type 22 mm Non-locking Flush Manual Override Valve Series L01 Solenoid on End Valve Function approx. [kg] 24 VDC 12/14 5-port., 2-pos. 0.200 236-127 24 VDC 12 5-port., 3-pos. 0.200 236-167 24 VDC 14 5-port., 3-pos. 0.200 236-133 12 VDC 12/14 5-port., 2-pos. 0.200 236-126 12 VDC 12 5-port., 3-pos. 0.200 236-166 12 VDC 14 5-port., 3-pos. 0.200 236-132 24 V / 50-60 Hz 12/14 5-port., 2-pos. 0.200 237-827 24 V / 50-60 Hz 12 5-port., 3-pos. 0.200 237-845 24 V / 50-60 Hz 14 5-port., 3-pos. 0.200 237-830 110 V / 50-60 Hz 12/14 5-port., 2-pos. 0.200 237-825 110 V / 50-60 Hz 12 5-port., 3-pos. 0.200 237-843 110 V / 50-60 Hz 14 5-port., 3-pos. 0.200 237-1008 230 V / 50-60 Hz 12/14 5-port., 2-pos. 0.200 237-962 230 V / 50-60 Hz 12 5-port., 3-pos. 0.200 237-844 230 V / 50-60 Hz 14 5-port., 3-pos. 0.200 237-829 Incl. solenoid cover, screws and gaskets More s on request Photo shows solenoid for 5-ported, 2-position valve Photo shows solenoid for 5-ported, 3-position valve Solenoids with Cables Flush Non-locking Manual Override Valve Series L01 Solenoid on End Valve Function approx. [kg] More s on request Photo shows solenoid for 5-ported, 2-position valve 521 24 VDC 12/14 5-port., 2-pos. 0.100 236-103 24 VDC 12 5-port., 3-pos. 0.100 236-155 24 VDC 14 5-port., 3-pos. 0.100 236-109 12 VDC 12/14 5-port., 2-pos. 0.100 236-102 12 VDC 12 5-port., 3-pos. 0.100 236-154 12 VDC 14 5-port., 3-pos. 0.100 236-108 24 V / 50-60 Hz 12/14 5-port., 2-pos. 0.100 237-839 24 V / 50-60 Hz 12 5-port., 3-pos. 0.100 237-851 24 V / 50-60 Hz 14 5-port., 3-pos. 0.100 237-842 110 V / 50-60 Hz 12/14 5-port., 2-pos. 0.100 237-837 110 V / 50-60 Hz 12 5-port., 3-pos. 0.100 237-849 110 V / 50-60 Hz 14 5-port., 3-pos. 0.100 237-840 230 V / 50-60 Hz 12/14 5-port., 2-pos. 0.100 237-838 230 V / 50-60 Hz 12 5-port., 3-pos. 0.100 237-850 230 V / 50-60 Hz 14 5-port., 3-pos. 0.100 237-841 Incl. solenoid cover, screws and gaskets Photo shows solenoid for 5-ported, 2-position valve

Line-Mounted L Series Accessories Solenoids Solenoids with Plug-in Device for Female Connector to Industrial Form, Type 22 mm without Exchangeable Pilot Coil Valve Series L1 / L2 Option L approx. [kg] 24 VDC, 3.35 Watt B 0.100 226-749 24 V / 50-60 Hz; 10 / 7 VA 0 0.100 237-568 110 V / 50-60 Hz; 10 / 7 VA 0 0.100 237-569 230 V / 50-60 Hz; 10 / 7 VA 0 0.100 237-570 Incl. screws and gaskets Solenoids with Plug-in Device for Female Connector to DIN EN 175301-803 (old DIN 43650) Form B, Type 22 mm without Exchangeable Pilot Coil Valve Series L1 / L2 Option L approx. [kg] 522 24 VDC, 3.35 Watt A 0.100 226-891 24 V / 50-60 Hz; 10 / 7 VA A 0.100 237-696 230 V / 50-60 Hz; 10 / 7 VA A 0.100 237-698 Incl. screws and gaskets Note: Magnets with 110 V/50-60 cycles per second are only available for exchangeable pilot coil assembly. www.numatics.com Pneumatic-Catalogue-GB-09/05

Line-Mounted L Series Accessories Exchangeable Pilot Coils Exchangeable Pilot Coils Type 22 mm or Type 30 mm for Series L1 / L2 / S2 / NA2 / NE2 and L8 picture shows exchangeable pilot coils type 22 mm Exchangeable pilot coil Exchangeable pilot coil Exchangeable pilot coil mit push/locking with non-locking without (standard) Version A B C D E F G appr. [kg] L 10 bar 16 bar Exchangeable pilot coils type 22 mm With push/locking 51.5 14.0 22.0 17.0 4.5 M8x0.75 M3 0.030 219-468 219-494 With non-locking 51.5 14.0 22.0 17.0 4.5 M8x0.75 M3 0.030 219-479 219-495 Without 51.5 14.0 22.0 17.0 4.5 M8x0.75 M3 0.030 219-467 219-493 Exchangeable pilot coils type 30 mm With push/locking 59.0 30.0 32.0 4.5 M8x0.75 M4 0.065 219-218 219-221 With non-locking 59.0 30.0 32.0 4.5 M8x0.75 M4 0.065 219-217 219-220 Without 59.0 30.0 32.0 4.5 M8x0.75 M4 0.065 219-216 219-219 With non-locking 3-port., 2-pos. function (NO) 59.0 30.0 32.0 4.5 M8x0.75 M4 0.065 219-489 Exchangeable pilot coils type 22 mm STAINLEES STEEL VERSION With non-locking 3-port., 2-pos. function (NC) Exhaust Protection Screw for Exchangeable Pilot Coils 51.5 14.0 22.0 17.0 4.5 M8x0.75 M3 0.030 219-550 Description approx. [gr] Exhaust protection screw 1.850 125-1027 523

Line-Mounted L Series Accessories Solenoids for Exchangeable Pilot Coils Solenoids to Industrial Form, Type 22 mm for Series L1 / L2 / S2 / NA2 / NE2, with Exchangeable Pilot Coil Option A B C L approx. [kg] - 24 VDC B 28.8 29.5 22.0 0.054 225-479 24 V / 50-60 Hz; 0 28.8 29.5 22.0 0.054 228-794 8.5 / 6.9 VA 110 V / 50-60 Hz; 8.5 / 6.9 VA 230 V / 50-60 Hz; 8.5 /6.9 VA Solenoids to Industrial Form, Type 22 mm with UL- and CSA-approval for Series L1 / L2 / S2 / NA2 / NE2, with Exchangeable Pilot Coil 0 28.8 29.5 22.0 0.054 228-791 0 28.8 29.5 22.0 0.054 228-790 Option A B C appr. [kg] 24 VDC; 48 V / 50-60 Hz C 28.8 29.5 22.0 0.054 225-506 60 VDC; 110 V / 50-60 Hz C 28.8 29.5 22.0 0.054 228-793 Solenoid to DIN EN 175301-803 (old DIN 43650) Form B, Type 22 mm for Series L1 / L2 / S2 / NA2 / NE2, with Exchangeable Pilot Coil Option A B C approx. [kg] 24 VDC A 28.8 29.5 22.0 0.054 225-478 24 V / 50-60 Hz A 28.8 29.5 22.0 0.054 228-872 110 V / 50-60 Hz A 28.8 29.5 22.0 0.054 228-874 230 V / 50-60 Hz A 28.8 29.5 22.0 0.054 228-789 524 www.numatics.com Pneumatic-Catalogue-GB-09/05

Line-Mounted L Series Accessories Solenoids for Exchangeable Pilot Coils Solenoid to ISO 20401 with M12 Connector and LED or DESINA Standard Connector M12 and LED, Type 22 mm, for Series L1 / L2 / S2 / NA2 / NE2, with Exchangeable Pilot Coil Drawing shows M12 connector with LED (same dimensions) Description Option A B C D M12 connector with LED DESINA standard with LED and connector M12 - approx. [kg] 24 VDC T 32.3 29.5 22.0 M12x1 0.065 225-477 24VDC 7 32.3 29.5 22.0 M12x1 0.065 225-482 Solenoid to ISO 20401 with M12 Connector and LED or DESINA Standard Connector M12 and LED, Type 30 mm, for L8 Series Drawing shows M12 connector with LED, 2 pins (same dimensions) Description Option Version A B C D M12 connector with LED, 2 pins M12 connector mit LED, 2 pins DESINA standard connector M12, 4 pins DESINA standard connector M12, 4 pins 24 VDC. 2.7 W 24 VDC. 6.8 W 24 VDC. 2.7 W 24 VDC. 6.8 W * only available with 16 bar 3-port., 2-pos. function NO pilot system appr. [kg] - T 10 bar 38.4 29.5 30.0 M12x1 0.110 225-485 T 16 bar* 38.4 29.5 30.0 M12x1 0.110 225-486 7 10 bar 38.4 29.5 30.0 M12x1 0.110 225-483 7 16 bar* 38.4 29.5 30.0 M12x1 0.110 225-484 525

Line-Mounted L Series Accessories Solenoids for Exchangeable Pilot Coils Solenoid to DIN EN 175301-803 (old DIN 43650) Form A, Type 30 mm for Series L1 / L2 / S2 / NA2 / NE2 with Exchangeable Pilot Coil and L8 Series Option Version A B C L1 / L2 / S2 NA2 / NE22 L8 L appr. [kg] 24 VDC, 2.7 Watt 4 S 10 bar 35.5 30.0 30.0 0.100 225-354 24 V / 50-60 Hz, 5.2 / 3.9 VA 2 S 10 bar 35.5 30.0 30.0 0.100 228-772 110 V / 50-60 Hz, 4.8 / 3.6 VA and 42 / 48 / 60 VDC, 2.5 / 3.4 / 5.3 W 2 S 10 bar 35.5 30.0 30.0 0.100 228-773 230 V / 50-60 Hz, 4.9 / 3.7 VA and 110 VDC, 3.9 W 24 VDC, 6.8 Watt and 42 / 48 V / 50-60 Hz 9.9 / 7.1 W 24 V / 50-60 Hz,10.8 / 7.6 VA and 12 VDC, 7.8 W 110 V / 50-60 Hz, 10.5 / 7.6 VA and 48 / 60 VDC, 5.3 / 8.3 W 230 V / 50-60 Hz, 10.5 / 7.6 VA and 110 VDC, 6.3 W 2 S 10 bar 35.5 30.0 30.0 0.100 228-774 4 S 16 bar* 35.5 30.0 30.0 0.100 225-355 2 S 16 bar* 35.5 30.0 30.0 0.100 228-775 2 S 16 bar* 35.5 30.0 30.0 0.100 228-776 2 S 16 bar* 35.5 30.0 30.0 0.100 228-777 * with 16 bar exchangeable pilot coil only Solenoid to DIN EN 175301-803 (old DIN 43650) Form A, Type 30 mm with UL- and CSA-Approval for L8 Series 526 Option Version A B C L appr. [kg] 24 VDC, 2.7 Watt C 10 bar 35.5 30.0 30.0 0.100 225-480 110 V / 50-60 Hz, 4.9 / 3.6 Watt C 10 bar 35.5 30.0 30.0 0.010 228-792 www.numatics.com Pneumatic-Catalogue-GB-09/05

Line-Mounted L Series Accessories Female Connectors Female Connector to DIN EN 175301-803 (old DIN 43650) Form A Female connector with PG 9 screw fi tting cable Female connector with 2-m-cable with PG 9 screw fi tting cable for cable with Ø 6 to Ø 8 mm with 2-m-cable Technical Data and Nominal Wiring Type With PG 9 screw fitting cable Diag. Colour Peak cut-off A B C L approx. [kg] Up to 250 V gray unlimited 49.0 28.0 18.0 0.020 230-592 Up to 250 V black unlimited 49.0 28.0 18.0 0.020 230-593 10-50 V LED red "a" transparent unlimited 49.0 28.0 18.0 0.020 230-582 10-30 V LED red + Varistor "b" transparent 65 V 49.0 28.0 18.0 0.020 230-567 70-250 V LED red "a" transparent unlimited 49.0 28.0 18.0 0.020 230-584 70-250 V LED red + Varistor "b" transparent 440 V 49.0 28.0 18.0 0.020 230-585 10-30 V LED green + Varistor "b" transparent 65 V 49.0 28.0 18.0 0.020 230-587 10-50 V LED green "a" transparent unlimited 49.0 28.0 18.0 0.020 230-586 70-250 V LED green "a" transparent unlimited 49.0 28.0 18.0 0.020 230-588 70-250 V LED green + Varistor "b" transparent 440 V 49.0 28.0 18.0 0.020 230-589 With 2-m-cable Up to 250 V black unlimited 44.0 27.5 18.0 0.020 230-412 24 V LED yellow + Varistor "b" black 65 V 44.0 27.5 18.0 0.020 230-413 110 V LED yellow + Varistor "c" black 260 V 44.0 27.5 18.0 0.020 230-414 220 V LED yellow + Varistor "c" black 470 V 44.0 27.5 18.0 0.020 230-415 Circuit diagram "a" Circuit diagram "b" Circuit diagram "c" 527

Line-Mounted L Series Accessories Female Connectors Female Connector to DIN EN 175301-803 (old DIN 43650) Form B Female connector with PG 9 screw fi tting cable Female connector with 2-m-cable LED yellow with PG 9 screw fi tting cable for cable with Ø 6 bis Ø 8 mm with 2-m-cable Technical Data and Nominal Type Wiring With PG 9 screw fitting cable Diag. Colour Peak cut-off voltage A B C D E F G L app. [kg] Up to 250 V gray unlimited 28.0 49.0 30.0 21.0 10.0 3.5 5.5 0.020 230-467 Up to 250 V black unlimited 28.0 49.0 30.0 21.0 10.0 3.5 5.5 0.020 230-468 10-50 V LED yellow "a" transparent unlimited 28.0 49.0 30.0 21.0 10.0 3.5 5.5 0.020 230-469 10-30 V LED yellow + Varistor "b" transparent 65 V 28.0 49.0 30.0 21.0 10.0 3.5 5.5 0.020 230-470 70-250 V LED yellow "a" transparent unlimited 28.0 49.0 30.0 21.0 10.0 3.5 5.5 0.020 230-471 70-250 V LED yellow + Varistor "b" transparent 440 V 28.0 49.0 30.0 21.0 10.0 3.5 5.5 0.020 230-472 With 2-m-cable Up to 250 V black unlimited 28.0 49.0 30.0 21.0 10.0 3.5 5.5 0.200 230-473 24 V LED yellow + Varistor "b" black 65 V 28.0 49.0 30.0 21.0 10.0 3.5 5.5 0.200 230-563 110 V LED yellow + Varistor "b" black 260 V 28.0 49.0 30.0 21.0 10.0 3.5 5.5 0.200 230-564 220 V LED yellow + Varistor "b" black 470 V 28.0 49.0 30.0 21.0 10.0 3.5 5.5 0.200 230-565 Circuit diagram "a" Circuit diagram "b" 528 www.numatics.com Pneumatic-Catalogue-GB-09/05

Female Connector to Industrial Form Line-Mounted L Series Accessories Female Connectors Female connector with PG 9 screw fi tting cable Female connector with 2-m-cable LED with PG 9 screw fi tting cable for cable with Ø 6 to Ø 8 mm with 2-m-cable Technical Data and Nominal Type Wiring With PG 9 screw fitting cable Diag. Colour Peak cut-off A B C D E F G appr. [kg] Up to 250 V gray unlimited 28.0 49.0 30.0 21.0 11.0 6.0 8.5 0.020 230-363 Up to 250 V black unlimited 28.0 49.0 30.0 21.0 11.0 6.0 8.5 0.020 230-364 10-50 V LED red "a" transparent unlimited 28.0 49.0 30.0 21.0 11.0 6.0 8.5 0.020 230-391 10-30 V LED red + Varistor "b" transparent 65 V 28.0 49.0 30.0 21.0 11.0 6.0 8.5 0.020 230-392 70-250 V LED red "a" transparent unlimited 28.0 49.0 30.0 21.0 11.0 6.0 8.5 0.020 230-393 70-250 V LED red + Varistor "b" transparent 440 V 28.0 49.0 30.0 21.0 11.0 6.0 8.5 0.020 230-394 10-30 V LED green + Varistor "b" transparent 65 V 28.0 49.0 30.0 21.0 11.0 6.0 8.5 0.020 230-400 10-50 V LED green "a" transparent unlimited 28.0 49.0 30.0 21.0 11.0 6.0 8.5 0.020 230-401 70-250 V LED green "a" transparent unlimited 28.0 49.0 30.0 21.0 11.0 6.0 8.5 0.020 230-402 70-250 V LED green + Varistor "b" transparent 440 V 28.0 49.0 30.0 21.0 11.0 6.0 8.5 0.020 230-403 With 2-m-cable Up to 250 V black unlimited 30.0 44.0 28.0 21.5 11.0 6.0 8.5 0.200 230-408 24 V LED yellow + Varistor "b" black 65 V 30.0 44.0 28.0 21.5 11.0 6.0 8.5 0.200 230-409- xxm 110 V LED yellow + Varistor "b" black 260 V 30.0 44.0 28.0 21.5 11.0 6.0 8.5 0.200 230-410 220 V LED yellow + Varistor "b" black 470 V 30.0 44.0 28.0 21.5 11.0 6.0 8.5 0.200 230-411 xxm = add the required cable lenght in m (e. g. 230-409-05m) standards are: 2, 5 and 10 m Circuit diagram "a" Circuit diagram "b" 529

M12 Straight Female Connector Line-Mounted L Series Accessories Female Connectors view on mating side Description A B C D approx. [kg] M12 straight 5 pin female connector, without cable 52.5 20.0 SW19 M12x1 0.033 230-957 M12 Elbow Female Connector view on mating side Description A B C D E approx. [kg] M12 elbow 5 pin female connector, without cable 35.0 20.0 SW19 M12x1 27.5 0.025 230-956 530 www.numatics.com Pneumatic-Catalogue-GB-09/05

Line-Mounted L Series Conversion of Pilot Air Supply Pilot Plugging Arrangements Series L1 and L2 When converting from internal to external pilot supply, please proceed as follows: 1.) Remove plug in solenoid mounting plate. 2.) Loosen the two M3 bolts (L1 series) or M4 bolts (L2 series), unmount solenoid mounting plate and insert gasket as shown in fi g. b). 3.) Re-mount and fasten solenoid mounting plate. (Torque approx. 1.5 Nm (L1 series) or 2.3 Nm (L2 Series)). Make sure that gaskets are inserted correctly. M3/M4 bolts fi g. a) Position of gasket in the solenoid mounting part with internal pilot supply. fi g. b) Position of gasket in the solenoid mounting part with external pilot supply. The plug has been removed. plug plug Orifi ce for internal pilot supply of port 1 Pilot Plugging Arrangements Series L8 When converting from internal to external pilot supply, please proceed as follows: 1.) Remove plug in solenoid mounting plate. 2.) Loosen the two M5 bolts, unmount solenoid mounting plate. Exchange the small O-ring and the small sealing disc as shown in fi g. a) and fi g. b). 3.) Re-mount and fasten solenoid mounting plate. (Torque approx. 4.5 Nm). Make sure that gaskets are inserted correctly. M5 bolts plug fi g. a) Position of O-Ring and sealing disc in the solenoid mounting part with internal pilot supply. Orifi ce for internal pilot supply of port 1 O-Ring fi g. b) Position of O-Ring and sealing disc in the solenoid mounting part with external pilot supply. The plug has been removed. sealing disc 531