DCS Input/Output Relay Card Series

Size: px
Start display at page:

Download "DCS Input/Output Relay Card Series"

Transcription

1 Input/Output Relay Card Series I/O RELAY CARD (with loopback test function) 8N The 8N series I/O Relay Cards easily and quickly standardize and facilitate installation of the relay board. Loopback test function simplifies startup and maintenance. The Standard Rack (Nest) model 8N can accept at the maximum of 16 channels of inputs and outputs. Input and output on one card Output /OFF switch and LED indicating relay status Test switch provided for checking operation Fuse provided to each channel for electromagnetic valve Output current capacity A Output can be jumper selectable: voltage output for electromagnetic valve or dry contact output. & SUFFIX CODE SELECTI CNECTOR H1 : Hitachi connector Y1 :Yokogawa KS2 cable use connector OPTIS Mounting : Rack mounting, standard (blank) /W : Surface mounting < STANDARD RACK (nest) > 8N B TERMINAL CNECTI CTROLLER CTROLLER CN1 CN U(+) V( ) POWER FOR VOLTAGE FUSE ALARM FOR VOLTAGE + 2VDC POWER ORDERING INFORMATI Specify code number. (e.g. 8N-BH1) MOUNTING REQUIREMENTS mm (inch) GENERAL SPECIFICATIS Construction: metal plates assembly; angle bracket mounting; JIS or EIA standard rack Capacity: 16 positions Painting: black Power input: supplied to I/O cards collectively Output: front accessed connector and screw terminals; one fuse alarm output for all 16 channels Screw terminal material: nickel-plated brass (torque 0.8 N m) INSTALLATI Power input: 2V DC ±10% (ripple 10% p-p max.) Operating temperature: -5 to +55 C (2 to 11 F) Operating humidity: 0 to 90% RH (non-condensing) Mounting: rack or surface Dimensions: W80 H19 D11 mm (18.90" 5.87" 5.16") Weight: 2.5 kg (5.5 lbs) PERFORMANCE Insulation resistance: 100MΩ with 500V DC Dielectric strength: 1000V minute (.00)* 65 (18.1) 50 (17.72) M5 SCREW ANGLE BRACKET Observe an appropriate wiring space below. *100 (.9) for JIS standard P. 1 / 10

2 8N EXTERNAL DIMENSIS mm (inch) RACK (standard) SURFACE (option /W) (17.8) 28 (1.10) 10 (.06) 1.6 (.06) 11 (5.16) CNECTOR CNECTOR 80 (18.90) 65 (18.1) 19 (5.87) (.00) C N 1 C N M.5 MTG SCREWS RACK TERMINALS HITACHI 8N-BH1: Hitachi connector Amphenol 57, 6-pin Connector Pin Assignments CN1: input CN2: output PIN NO. ASSIGNMENT PIN NO. ASSIGNMENT 1 ch ch ch ch.10 + ch ch.11 + ch ch ch ch ch ch ch ch ch ch COM 27 COM 17, 18, 20 26, 28 6: Unused Pin assignments are the same for both CN1 and CN2. YOKOGAWA 8N-BY1: Yokogawa connector PS-0PE-DLT1-PN1 Location for ST card CN1: input (KS2 cable use) CN2: output (KS2 cable use) 8-RACK LOCATI NO ST2 / ST / ST CARD / NO. Pin assignments are the same for both CN1 and CN2. Specifications subject to change without notice. P. 2 / 10

3 & SUFFIX CODE SELECTI 8N 2 Dry contact or open collector Voltage or dry contact (jumper selectable) FUNCTI 2 :Test circuit ORDERING INFORMATI Specify code number. (e.g. 8N-2) GENERAL SPECIFICATIS Construction: rack mounted; terminal access via screw terminals at the front and via connector at the rear Connection Input: M.5 screw terminals I/O: card-edge connector Output: M.5 screw terminals Power input: supplied from card-edge connector Screw terminal material: nickel-plated steel (torque 0.8 N m) Fuse: 0.5A Alarm contact: dry contact output at the screw terminal when the fuse is blown Isolation: input or power to output Test switch: LED provided DISCTINUED Replaced with Model 8N2-2 CTACT : dry contact or open collector Contact detecting: 2V DC, approx. 20mA < LOOPBACK I/O RELAY CARD > ELECTROMAGNETIC VALVE: voltage contact Rated load: 120V (cosø=1) 2V (resistive load) Load current: 8A max. for the total of 16 channels DRY CTACT: dry contact (electromagnetic valve or dry contact selectable with the jumper on the PCB) Rated load: 120V (cosø=1) 2V (resistive load) Relay protection: For maximum relay life with inductive loads (e.g. coil), external protection including noise quenching is recommended. STATUS : relay contact Rated load: 0V (resistive load) INSTALLATI Power input: 2V DC ±10%, approx. 5mA (ripple 10% p-p max.) Operating temperature: -5 to +55 C (2 to 11 F) Operating humidity: 0 to 90% RH (non-condensing) Mounting: Standard Rack 8N-B Dimensions: W2 H19 D102 mm (0.91" 5.87".02") Weight: 150 g (0. lbs) PERFORMANCE Insulation resistance: 100MΩ with 500V DC Dielectric strength: 1000V minute Relay life: mechanical life cycles electrical life 10 5 cycles (0 cycles/min. at rated load) FRT VIEW mm (inch) STATUS : dry contact or open collector Contact detecting: 2V DC, approx. 20mA SW2 LED 19 (5.87) FUSE M.5 SCREWS 2 (.91) P. / 10

4 8N OPERATIS SW2 LED LED STATUS STATUS (IN) CTACT A* CTACT B* (OUT) OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF / OFF OFF / OFF OFF OFF TEST / OFF OFF OFF OFF OFF / OFF OFF OFF OFF OFF OFF N/A OFF OFF N/A *Selectable with a jumper. SCHEMATIC CIRCUITRY & CNECTI DIAGRAM POWER CNECTOR JUMPER 2 B A TEST X1 X2 X SW2 X OFF POWER FOR VOLTAGE FUSE ALARM FOR VOLTAGE ALARM FUSE CTACT ELECTRO- MAGNETIC VALVE CARD TERMINALS DRY CTACT When the dry contact output is selected with the jumper. Specifications subject to change without notice. P. / 10

5 & SUFFIX CODE SELECTI 8N2 2 Dry contact or open collector Voltage or dry contact (jumper selectable) FUNCTI 2 :Test circuit ORDERING INFORMATI Specify code number. (e.g. 8N2-2) GENERAL SPECIFICATIS Construction: rack mounted; terminal access via screw terminals at the front and via connector at the rear Connection Input: M.5 screw terminals I/O: card-edge connector Output: M.5 screw terminals Power input: supplied from card-edge connector Screw terminal material: nickel-plated steel (torque 0.8 N m) Fuse: 0.5A Alarm contact: dry contact output at the screw terminal when the fuse is blown Isolation: input to power or output or contact input to electromagnetic valve output (or dry contact output) to alarm output Test switch: LED provided CTACT : dry contact or open collector Contact detecting: 2V DC, approx. 25mA STATUS : dry contact or open collector Contact detecting: 2V DC, approx. 25mA < LOOPBACK I/O RELAY CARD > ELECTROMAGNETIC VALVE: voltage contact Rated load: 120V (cosø=1) 2V (resistive load) Load current: 8A max. for the total of 16 channels DRY CTACT: dry contact (electromagnetic valve or dry contact selectable with the jumper on the PCB) Rated load: 120V (cosø=1) 2V (resistive load) Relay protection: For maximum relay life with inductive loads (e.g. coil), external protection including noise quenching is recommended. STATUS : relay contact Rated load: 0V (resistive load) INSTALLATI Power input: 2V DC ±10%, approx. 65mA (ripple 10% p-p max.) Operating temperature: -5 to +55 C (2 to 11 F) Operating humidity: 0 to 90% RH (non-condensing) Mounting: Standard Rack 8N-B Dimensions: W2 H19 D102 mm (0.91" 5.87".02") Weight: 150 g (0. lbs) PERFORMANCE Insulation resistance: 100MΩ with 500V DC Dielectric strength: 1000V minute Relay life: mechanical life cycles electrical life 10 5 cycles (0 cycles/min. at rated load) FRT VIEW mm (inch) SW2 LED 19 (5.87) FUSE M.5 SCREWS 2 (.91) P. 5 / 10

6 8N OPERATIS SW2 LED LED STATUS STATUS (IN) CTACT A* CTACT B* (OUT) OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF / OFF OFF / OFF OFF OFF TEST / OFF OFF OFF OFF OFF / OFF OFF OFF OFF OFF OFF N/A OFF OFF N/A *Selectable with a jumper. SCHEMATIC CIRCUITRY & CNECTI DIAGRAM POWER CNECTOR JUMPER 2 B A TEST X1 X2 X SW2 X OFF POWER FOR VOLTAGE FUSE ALARM FOR VOLTAGE ALARM FUSE CTACT ELECTRO- MAGNETIC VALVE CARD TERMINALS DRY CTACT When the dry contact output is selected with the jumper. Specifications subject to change without notice. P. 6 / 10

7 DISCTINUED Replaced with Model 8N2- & SUFFIX CODE SELECTI Dry contact or open collector Relay contact FUNCTI : Motor drive use ORDERING INFORMATI Specify code number. (e.g. 8N-) <MOTOR DRIVE I/O RELAY CARD > 8N INSTALLATI Power input: 2V DC ±10%, approx. 80mA (ripple 10% p-p max.) Operating temperature: -5 to +55 C (2 to 11 F) Operating humidity: 0 to 90% RH (non-condensing) Mounting: Standard Rack 8N-B Dimensions: W2 H19 D102 mm (0.91" 5.87".02") Weight: 150 g (0. lbs) PERFORMANCE Insulation resistance: 100MΩ with 500V DC Dielectric strength: 1000V minute Relay life: mechanical life cycles electrical life 10 5 cycles (0 cycles/min. at rated load) GENERAL SPECIFICATIS Construction: rack mounted; terminal access via screw terminals at the front and via connector at the rear Connection Input: M.5 screw terminals I/O: card-edge connector Output: M.5 screw terminals Power input: supplied from card-edge connector Screw terminal material: nickel-plated steel (torque 0.8 N m) Isolation: output or power or feedback input to motor drive to input Indicator LED: orange light turns on when the motor is started up. red light turns on when the feedback input is turned on. FRT VIEW mm (inch) 19 (5.87) 2 (.91) LED (orange) LED (red) M.5 SCREWS FEEDBACK : dry contact or open collector Contact detecting: 2V DC, approx. 25mA STATUS : dry contact or open collector Contact detecting: 2V DC, approx. 50mA MOTOR DRIVE : relay contact Rated load: 250V (cosø=1) 0V (resistive load) Relay protection: For maximum relay life with inductive loads (e.g. coil), external protection including noise quenching is recommended. STATUS : relay contact Rated load: 0V (resistive load) P. 7 / 10

8 8N OPERATIS t t t Output Feedback Motor Drive t = 2.5 to 5 sec. SCHEMATIC CIRCUITRY & CNECTI DIAGRAM POWER OFF One-Shot Relay Driver 1 FEEDBACK CNECTOR 2 MOTOR DRIVE M X1 X2 X Specifications subject to change without notice. P. 8 / 10

9 <MOTOR DRIVE I/O RELAY CARD > & SUFFIX CODE SELECTI Dry contact or open collector Relay contact FUNCTI : Motor drive use ORDERING INFORMATI Specify code number. (e.g. 8N2-) GENERAL SPECIFICATIS 8N2 Construction: rack mounted; terminal access via screw terminals at the front and via connector at the rear Connection Input: M.5 screw terminals I/O: card-edge connector Output: M.5 screw terminals Power input: supplied from card-edge connector Screw terminal material: nickel-plated steel (torque 0.8 N m) Isolation: output or power or feedback input to motor drive to input Indicator LED: orange light turns on when the motor is started up. red light turns on when the feedback input is turned on. INSTALLATI Power input: 2V DC ±10%, approx. 95mA (ripple 10% p-p max.) Operating temperature: -5 to +55 C (2 to 11 F) Operating humidity: 0 to 90% RH (non-condensing) Mounting: Standard Rack 8N-B Dimensions: W2 H19 D102 mm (0.91" 5.87".02") Weight: 150 g (0. lbs) PERFORMANCE Insulation resistance: 100MΩ with 500V DC Dielectric strength: 1000V minute Relay life: mechanical life cycles electrical life 10 5 cycles (0 cycles/min. at rated load) FRT VIEW mm (inch) 19 (5.87) LED (orange) LED (red) M.5 SCREWS FEEDBACK : dry contact or open collector Contact detecting: 2V DC, approx. 5mA 2 (.91) STATUS : dry contact or open collector Contact detecting: 2V DC, approx. 60mA MOTOR DRIVE : relay contact Rated load: 250V (cosø=1) 0V (resistive load) Relay protection: For maximum relay life with inductive loads (e.g. coil), external protection including noise quenching is recommended. STATUS : relay contact Rated load: 0V (resistive load) P. 9 / 10

10 8N OPERATIS t t t Output Feedback Motor Drive t = 2.5 to 5 sec. SCHEMATIC CIRCUITRY & CNECTI DIAGRAM POWER OFF One-Shot Relay Driver 1 FEEDBACK CNECTOR 2 MOTOR DRIVE M X1 X2 X Specifications subject to change without notice. P. 10 / 10

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

Absolute Rotary Encoder E6CP

Absolute Rotary Encoder E6CP Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the

More information

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB. 7I29 MANUAL Rev 1.5 CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB. THE 7I29 IS INTENDED FOR USE BY OEMS THAT WILL INTEGRATE IT INTO A SYSTEM WITH INTERLOCKS AND

More information

Brushless DC Motors Intro duction BLF BLU BLH Installation. Brushless DC Motors. DC Input. AC Input DC Input. BLH Series. Page. BLH Series B-52 B-51

Brushless DC Motors Intro duction BLF BLU BLH Installation. Brushless DC Motors. DC Input. AC Input DC Input. BLH Series. Page. BLH Series B-52 B-51 DC Input BLH Series Brushless DC Motors Intro duction BLF BLU BLH Installation C Input DC Input Page BLH Series B-52 B-51 RoHS-Compliant Brushless DC Motor and Package BLH Series The BLH Series combines

More information

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES AC averaging technique used to rectify, amplify, and filter 50 Hz to 400 Hz sine-wave signals. Accepts inputs of between 20 mv to 550 V rms to give

More information

PSDC 08128. PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

PSDC 08128. PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC. PSDC 08128 v.1.2 PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC. EN** Edition: 9 from 25.05.2015 Supersedes the edition: 8 from 12.12.2014 the 8x 1A/12V DC power output for powering

More information

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,

More information

LM10. Micro Laser Displacement Sensor. The LM10 makes laser sensors super easy to use! New circuitry lowers costs

LM10. Micro Laser Displacement Sensor. The LM10 makes laser sensors super easy to use! New circuitry lowers costs 857 Micro Sensor General terms and conditions... P.1 Related Information Glossary of terms / General precautions... P.1019 / P.1027 Sensor selection guide... P.11~ / P.833~ About laser beam... P.1025 ~

More information

Solid-State Timer H3G

Solid-State Timer H3G ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-11000(India) Tel : 011-43797575 Fax : 011-43797574 E-mail : sales@ashalain.com Solid-State Timer Low-Cost, Plug-In

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2 Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened

More information

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads: Automation / Mini Type SCH32F Hollow Shaft Encoder - Ø 32 mm Hollow Bore: Ø 6 mm to Ø 3/8 inch Resolution up to 5000 ppr IP 65 (IP 50 for IDC connector option) Electrical Specifications Code: Resolution:

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED)

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED) NX SERIES Compact Multi-voltage Photoelectric Power Supply Built-in Multi-voltage photoelectric sensor usable worldwide Conforming to ow Voltage and EMC Directive Multi-voltage The NX series can operate

More information

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter FEATURES: Click on Series name for product info on aimtec.com Models Single output Model Max Output Power (W) 1 AC-DC Constant Current or Constant Over temperature protection Voltage LED Driver Over current

More information

Air damper actuators

Air damper actuators 4 634 OpenAir TM Air damper actuators GDB...1 GLB...1 Rotary version, / AC 230 V Electronic motor driven actuators for three-position and modulating control Nominal torque 5 Nm (GDB), 10 Nm (GLB) Mechanically

More information

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 v.1.0 AC/AC power supply unit Edition: 1 from 24 th October 2008 Supercedes edition: ---------- 10062009 CONTENTS: 1. Technical description. 1.1. General description

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Contents. Document information

Contents. Document information User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB

More information

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS LOW-PROFILE SURFACE-MOUNT RELAY RELAYS.55 5.6. FEATURES Low-profile: 6 mm.36 inch (Tape height: max. 6.5 mm.56 inch) Tape and reel package is available as standard packing style Surge withstand between

More information

Application Note TMA Series

Application Note TMA Series 1W, SIP, Single & Dual Output DC/DC Converters Features SIP Package with Industry Standard Pinout Package Dimension: 19.5 x 10.2 x 6.1 mm (0.77 x 0.4 x 0.24 ) 5V&12V Models 19.5 x 10.2 x 7.1 mm (0.77 x

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

帝 聞 企 業 股 份 有 限 公 司 DEE VAN ENTERPRISE CO., LTD. SP-235864 DSL-20WA 420024 1 Revision: A Date: 2011.10.24 FOR AC-DC LED DRIVER MODEL NO.

帝 聞 企 業 股 份 有 限 公 司 DEE VAN ENTERPRISE CO., LTD. SP-235864 DSL-20WA 420024 1 Revision: A Date: 2011.10.24 FOR AC-DC LED DRIVER MODEL NO. CUSTOMER: PART NUMBER: A200 APPROVAL SHEET FOR AC-DC LED DRIVER MODEL NO. DSL-20WA 420024 1 ORDER NO: SP-235864 承 認 書 确 認 后 請 簽 回 一 份 CUSTOMER APPROVED SIGNATURE DEE VAN ENTERPRISE CO., LTD (Head-Quarter)

More information

CQM1-SF200/CS1W-SF200

CQM1-SF200/CS1W-SF200 Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit

More information

GAE953 Electrical Alarm Unit 19" with Indicator

GAE953 Electrical Alarm Unit 19 with Indicator Master Instruction 08.95 MI EIO2211 A-(en) GAE953 Electrical Alarm Unit 19" with Indicator The electrical alarm unit GAE953 gives a signal when one or two set alarm values have been exceeded. Input signals

More information

UIM2901-5A MACH3 breakout board

UIM2901-5A MACH3 breakout board User Manual UIM2901-5A MACH3 Breakout Board UIM2901-5A MACH3 Breakout Board UIM2901-5A MACH3 breakout board Features General DB25 interface between PC and user device Fully buffered opto-isolated I/O (Input

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information

IEC Connectors. Introduction

IEC Connectors. Introduction Introduction IEC Connectors A full range of quality mains rated inlets, outlets and connectors conforming to IEC and EN 60320 specifications carrying UL, CSA, VDE and other approvals. With electrical ratings

More information

WD-AMX Water Detection Controllers

WD-AMX Water Detection Controllers Page 1 of 5 WD-AMX Water Detection Controllers Features: Benefit: LED Status of leak status VFC output Audible alarm Auto or manual reset alarm output Uses an isolated AC signal which prevents oxidation

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar. CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension

More information

QR12 (1.22 ) Diameter Optical Encoder

QR12 (1.22 ) Diameter Optical Encoder Improving the Quality of Life through the Power in Light QPhase QR12 (1.22 ) Diameter Optical Encoder Design Features: Low profile assembled height of Bearing design simplifies encoder attachment Resolutions

More information

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS FRANCE Head office USA 4 Rue du Bois Chêne le loup Parc d Activité de Brabois 54 500 VANDOEUVRE LES NANCY (33) 0383442413, Fax (33) 0383443797

More information

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector. Photoelectric Sensor with Built-in Amplifier Photoelectric Sensor with built-in amplifier is applicable to a wide variety of lines and ensures a longer sensing distance than any other model. User-friendly

More information

Solid-State Relays. Series Included. Solid-State Relays SIR...145 SLR...146 NLF...147. PHS Series PHS...148

Solid-State Relays. Series Included. Solid-State Relays SIR...145 SLR...146 NLF...147. PHS Series PHS...148 Solid-State Relays Included SIR....145 SLR....146 NLF....147 PHS PHS....148 Solid-State Relays 144 www.ssac.com 800-843-8848 fax: 605-348-5685 Solid-State Relay - Isolated SIR1 & SIR2 Designed for industrial

More information

www.sebury.com.cn Digital Keypad Use s Manual

www.sebury.com.cn Digital Keypad Use s Manual K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4

More information

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05 RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,

More information

Model CS 64 Mini-DIN Cable and Adaptor

Model CS 64 Mini-DIN Cable and Adaptor Model CS 64 Mini-DIN Cable and Adaptor Page 1 of 9 Features Hi-Pro and NOAHlink compatible cable & Mini-DIN CS 64 Clip Module / NOAHlink Adaptor #1 Integrated Clip Module - Mini-DIN Cable Integrated NOAHlink

More information

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual Infrastructure Management & Monitoring For Business-Critical Continuity Liebert icom-do User Manual TABLE OF CONTENTS 1.0 INTRODUCTION............................... 1 2.0 INSTALLATION...............................

More information

GENERIC REQUIREMENTS FOR UNINTERRUPTIBLE POWER SYSTEMS (UPS) TABLE OF CONTENTS

GENERIC REQUIREMENTS FOR UNINTERRUPTIBLE POWER SYSTEMS (UPS) TABLE OF CONTENTS TR TSY 000757 GENERIC REQUIREMENTS FOR UNINTERRUPTIBLE POWER SYSTEMS (UPS) TABLE OF CONTENTS 1. Introduction.... 1.1 Purpose and Scope 1.2 Organization.. 1.3 Reason for Reissue From Technical Advisory

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 mail@uni-valve.com www.uni-valve.com. Installation and operating manual

Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 mail@uni-valve.com www.uni-valve.com. Installation and operating manual Uni-Valve A /S VENTILER & INSTRUMENTER Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 mail@uni-valve.com www.uni-valve.com UNI-EL Electric actuator Installation and operating manual Remote position

More information

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................

More information

Smart DeviceNet Remote I/O Terminals

Smart DeviceNet Remote I/O Terminals Smart DeviceNet Remote I/O Terminals ather and Use Information for Effective Preventive Maintenance et more useful data for preventive maintenance when you build cost-effective parallel information systems

More information

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1. USER GUIDE Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator Version 1.3 DM Engineering 2174 Chandler St. Camarillo, CA 91345-4611 805-987-7881 800-249-0487

More information

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2 R Extended Range Inductive Prox Greater Sensing Distance Offers Greater Design Flexibility H Sensing distances approximately 1.5 to 2 times larger than that of any conventional Sensor H Reduces problems

More information

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component. Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on

More information

USER MANUAL V5.0 ST100

USER MANUAL V5.0 ST100 GPS Vehicle Tracker USER MANUAL V5.0 ST100 Updated on 15 September 2009-1 - Contents 1 Product Overview 3 2 For Your Safety 3 3 ST100 Parameters 3 4 Getting Started 4 4.1 Hardware and Accessories 4 4.2

More information

Incremental Rotary Encoder E6B2

Incremental Rotary Encoder E6B2 Incremental Rotary Encoder General-Purpose Rotary Encoder Withstands arge Shaft oads Wide variety of supply voltages and output forms Easy-to-adjust zero index (phase Z) with origin indicating function

More information

Contractors Guide Central Inverter System Installation

Contractors Guide Central Inverter System Installation Contractors Guide Central Inverter System Installation Step By Step Procedures 2,200 Watt/VA 6 Step Installation 1. Mount Bottom Cabinet 2. Mount Top Cabinet 3. Install Batteries 4. Install Conduit 5.

More information

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421 VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421 TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS... 1 2-1 General Specifications...1 2-2 Electrical Specifications... 2 3. FRONT PANEL DESCRIPTION... 4 3-1

More information

Know-how makes the difference. Electrical Actuators

Know-how makes the difference. Electrical Actuators Know-how makes the difference Electrical Actuators With Dansk Ventil Center as your business partner, you are always guaranteed a wide and well sorted product range and a unique technical know-how Product

More information

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

REGULINE 600VA / 1000VA REGULATOR USER MANUAL REGULINE 600VA / 1000VA REGULATOR USER MANUAL TUNÇMATİK REGULINE SERIES AUTOMATIC VOLTAGE REGULATOR Models: REGULINE 600VA / REGULINE 1000VA Principle of Operation Automatic Voltage Regulators regulate

More information

www.jameco.com 1-800-831-4242

www.jameco.com 1-800-831-4242 Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. SPECIFICATION CUSTOMER: JAMES DATE: 04.08.23 MODEL NO: DBU090030 DESIGNED

More information

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording Hardware & Installation Guide Algo Communication Products Ltd. Customer Support and Sales Tel: 1.877.884.2546 Fax: 604.437.5726 Email: sales@algosolutions.com support@algosolutions.com www.algosolutions.com

More information

How To Power A Schen

How To Power A Schen Automation / Mini Type SCH32F Hollow Shaft Encoder - Ø 32 mm Hollow Bore: Ø 6 mm to Ø 3/8 inch Resolution up to 5000 ppr IP 65 (IP 50 for IDC connector option) Electrical Specifications Code: Resolution:

More information

T1 Backhaul Connectivity Solution All Products :: Application Note

T1 Backhaul Connectivity Solution All Products :: Application Note Telect 1 RU Customer Interface Panel (CIP) Enables Demarcation, Remote Circuit Maintenance and Trouble Isolation at the Backhaul Node The Application: T1 Demarcation and Testing in Backhaul Environments

More information

DCP Fan Controller. Version 01/2009. The engineer s choice

DCP Fan Controller. Version 01/2009. The engineer s choice Version 01/2009 The engineer s choice Index Page 1. Introduction... 3 2. Technical specification... 4 3. Connection diagrams... 9 4. Configuration... 10 5. Compatible ebm-papst Fan List... 11 2 1. Introduction

More information

Adjustment functions for both span and shift have been incorporated

Adjustment functions for both span and shift have been incorporated SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8

More information

MechoNet TM Network Interface (MNI) Specification Submittal

MechoNet TM Network Interface (MNI) Specification Submittal MechoNet TM Network Interface (MNI) Specification Submittal Models MechoNet Network Interface: MNI RJ (RJ45 Motor Ports): Stock No.: IMNI 0001 TP AS (US version) Stock No.: IMNI 0004 TP AS (UK version)

More information

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.

More information

Digital Pressure Measuring Instrument MDR480

Digital Pressure Measuring Instrument MDR480 Description The digital panel instrument MDR480 is designed to measure, display, and monitor pressures in industrial applications. The instrument is panel mounted with a front frame dimension of 96 mm

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

Inductive Proximity Sensors

Inductive Proximity Sensors M12 Inductive Proximity Sensors Standard Length Mini's Extended Sensing 3 Wire DC 2 Wire DC 2 Wire AC (Wiring Schematic) 3 Wire DC PNP Normally Open (1) IMM32122C IMM35124C IMN32122C IMN35124C IMN32122M12

More information

Power Supplies 3. SDN-P DIN Rail Series

Power Supplies 3. SDN-P DIN Rail Series SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.

More information

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases

More information

Color Mark Sensor with Red or Green LED E3S-VS

Color Mark Sensor with Red or Green LED E3S-VS Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical

More information

FIREDEX 2200. Conventional Fire Panels

FIREDEX 2200. Conventional Fire Panels 68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class

More information

LOW PROFILE 2 FORM C RELAY 9.354 +0.4 5.197 0.2 +.016.008. mm inch. M.B.B.type. Initial breakdown voltage 1 A 30 V DC 30 W, 62.5 V A 30 W.

LOW PROFILE 2 FORM C RELAY 9.354 +0.4 5.197 0.2 +.016.008. mm inch. M.B.B.type. Initial breakdown voltage 1 A 30 V DC 30 W, 62.5 V A 30 W. TESTING LOW PROFILE FORM C RELA TQ-RELAS 9.35 6.7..5 5..6.8.55 9.35. 5..6.8 FEATURES High sensitivity: Form C: power consumption (single side stable type) Form C: 8 power consumption (single side stable

More information

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders

More information

RY2 miniature industrial relays

RY2 miniature industrial relays 6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,

More information

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS Solid-State Counter/Timer 1/16 DIN, Easy-to-Operate Combination Counter and Timer Operation selectable as preset counter or timer 6-digit LCD Present Value: 8 mm (.32 in) Set Value: 4 mm (.16 in) Nonsignificant

More information

Ordering Information. Short Barrel Inductive Prox E2E3-WIREDC. Short Barrel 3-Wire Prox Sensors Meet IP67

Ordering Information. Short Barrel Inductive Prox E2E3-WIREDC. Short Barrel 3-Wire Prox Sensors Meet IP67 R Short Barrel Inductive Prox E2E3-WIREDC Short Barrel 3-Wire Prox Sensors Meet IP67 H Thick nickel-plated brass barrel has wrench flats for easy installation H Solid potted internal circuitry withstands

More information

SELECTION GUIDE. Nominal Input

SELECTION GUIDE. Nominal Input www.murata-ps.com NKE Series FEATURES RoHS Compliant Sub-Miniature SIP & DIP Styles 3kVDC Isolation UL Recognised Wide Temperature performance at full 1 Watt load, 40 C to 85 C Increased Power Density

More information

Section D..General Auto Electrical Corporation

Section D..General Auto Electrical Corporation 43 Section D..General Auto Electrical Corporation 1. LED Based Signal unit GAEC manufacture LED based signaling system for use in electrified and non electrified sections of Indian railways. The exceptional

More information

BITMAIN. APW3-12-1600 PSU Series User Guide

BITMAIN. APW3-12-1600 PSU Series User Guide BITMAIN APW3-12-1600 PSU Series User Guide Contents 1 Overview... 3 2 Features... 3 3 Specifications... 4 4 Switching On/Off Remotely... 5 5 Order Information & Wire Type... 6 5.1 Order Information...

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics 3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,

More information

SECTION 28 23 23 VIDEO SURVEILLANCE SYSTEMS INFRASTRUCTURE

SECTION 28 23 23 VIDEO SURVEILLANCE SYSTEMS INFRASTRUCTURE PART 1 - GENERAL 1.1 SUMMARY SECTION 28 23 23 VIDEO SURVEILLANCE SYSTEMS INFRASTRUCTURE A. Section Includes 1. Video Surveillance Systems Infrastructure B. Related Sections 1. Section [28 23 16 Video Surveillance

More information

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models TML Series, 0 & 0 Watt Features C B Scheme LVD UL 090- Encapsulated power supplies with increased power density Replaces TML and TML 0 series PCB mount or chassis mount with screw terminals Single, dual

More information

U-shaped Micro Photoelectric Sensor

U-shaped Micro Photoelectric Sensor SERIES U-shaped Micro Photoelectric Extremely small size enables space saving and quick installation! Extremely small Ultra-small type PM- 24(-R) contributes to the miniaturization of your equipment. Even

More information

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables. Quick-Connect Cables with Connectors PA Simplifies sensor wiring. Wide variety of connectors attached to cables. Series No wiring or staking work needed Shorter replacement time in unlikely event of sensor

More information

Water Leak Detection System

Water Leak Detection System Water Leak Detection System Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email:info@rodisystems.com 936 Highway 516 Aztec, NM 87410-2828 Manual Revisions and Copyright

More information

TS93 EMR T/PT/TDE. Surface applied door closer

TS93 EMR T/PT/TDE. Surface applied door closer TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double

More information

Vario-Series Accessories

Vario-Series Accessories Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates

More information

12V Dimmable Driver EL-TMDRVR

12V Dimmable Driver EL-TMDRVR Elemental LED, LLC website: elementalled.com 11 9 5 P a r k A v e., S u i t e 2 11 Emeryville, CA 94608 toll free 877.564.5051 fax 510.740.4457 12V Dimmable Driver EL-TMDRVR ETL Listed #4001928 CSA Listed

More information

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

Features, Benefits, and Operation

Features, Benefits, and Operation Features, Benefits, and Operation 2014 Decibel Eleven Contents Introduction... 2 Features... 2 Rear Panel... 3 Connections... 3 Power... 3 MIDI... 3 Pedal Loops... 4 Example Connection Diagrams... 5,6

More information

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy

More information

Technical Overview Add-on Sensors - Smoke Alarm. Get yours direct at: 01491 410913 www.theclimate.co.uk

Technical Overview Add-on Sensors - Smoke Alarm. Get yours direct at: 01491 410913 www.theclimate.co.uk Technical Overview Add-on Sensors - Smoke Alarm Get yours direct at: 01491 410913 www.theclimate.co.uk OVERVIEW This kit contains a standard smoke alarm and relay pattress. The Kidde Smoke Alarm supplied

More information

400-800. Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction***

400-800. Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction*** INPUT Input protection Thermal protection Switching frequency internal fuse standard 100KHz Input with PFC : (MML400PFC, MML600, MML800) Input voltage range 85*-264VAC Inrush current (peak) MML400PFC

More information

SSC-T800series. New type with radial cross ray method. Light Curtain Sensors. Type. Radial Cross Ray Method. Detecting width. Light axis interval

SSC-T800series. New type with radial cross ray method. Light Curtain Sensors. Type. Radial Cross Ray Method. Detecting width. Light axis interval series Light Curtain Sensors New type with radial cross ray method Small objects and flat tape-like objects detected Convenient simplified wiring requiring no clock (synchronization) line Compact and flat

More information