Reocor D External Pacemaker



Similar documents
SimplyGo Quick-start guide

Basics of Pacing. Ruth Hickling, RN-BSN Tasha Conley, RN-BSN

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

Product and functional description

How to use the Panasonic NVGS300/280 digital video camera - New version

COMPALARM AP GENERAL MAIN FEATURES

Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet

Automatic Telephone Dialer TD-101(W)

PRODUCT SHEET OUT1 SPECIFICATIONS

Drayton Digistat +2RF/+3RF

PROXIMITY CARD READERS C-10, C-20, C60, C70

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

FiberOptix TM. AP Sensor Zeroing and Calibration Guide INTRA-AORTIC BALLOON PRODUCT SUPPORT HOTLINE. U.S. and Canada: IABP (4227)

FIREDEX Conventional Fire Panels

Test Equipment Solutions Datasheet

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

USER S GUIDE Humidity and Temperature USB Datalogger

FCC COMPLIANCE STATEMENT FOR AMERICAN USERS

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

HOBO U14 Data Logger User Manual

Testo FlashUpdate. Instument Software Update and Download Instructions How to Download Instrument Software and Updates from the Internet

RC Camera Control. User Guide v /20/2012

EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. Page 1 of 5

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

Installation & User Manual Radio Remote rev1.0.3

Alarm Security Kit - NVR

I STAR COMPUTER CO., LTD

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

PA500II Enterprise Mobile Computer

R Series Quick Reference Guide

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Product Information Sheet UH28CS-12kV Hi Pot Tester

Operating Manual for the Vetronic Services Sapphire Plus ECG System

How To Program An Autodialer

Digistat RF Troubleshooting Procedure

AIS750 Series Alarm Annunciator

PORTABLE PA SYSTEM #1 LAST UPDATED: FEBRUARY 2011

Building a Simulink model for real-time analysis V Copyright g.tec medical engineering GmbH

Current Monitoring Kit

Cable Plug acc. to DIN EN , Form A

MISE - STEREO ENCODER

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

SYSTEM DESCRIPTION Termination Boards

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Owner s Manual AWM910 JENSEN AWM910 COMPACT DISC PLAYER RADIO CD COMPACT MUSIC SYSTEM MUTE AUX BAND AUX IN PUSH PUSH PWR VOL ALARM T/F AUD SPK A SPK B

Notice. Reverse engineering and disassembly are prohibited.

How To Use A Power Supply On A Powerline 2.2 (Ai)

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Section III. Heart Mate II (2 nd Generation) III.41.1 EMT-BASIC EMT-INTERMEDIATE EMT-PARAMEDIC

INFRARED REMOTE CONTROL HELICOPTER

SCD Server. SCD Server Pro

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

Horns. Buzzers , Compressed air horns Disc-type horns Electric twin-tone horns 6.08

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

mysensors mysensors Wireless Sensors and Ethernet Gateway Quick Start Guide Information to Users Inside the Box mysensors Ethernet Gateway Quick Start

Mbox Basics Guide. Version 6.7 for LE Systems on Windows XP or Mac OS X. Digidesign

Part 2. Copyright 1998 Philips Consumer Communications L.P. All rights reserved. Printed in Mexico. Issue 1AT&T

TABLE OF CONTENTS. TABLE OF CONTENTS... 1 Package content INTRODUCTION Dear customer... 2 Features... 2 Caution... 2

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Charge Controller CC611/CC612 Preliminary datasheet

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Pacers use a 5-letter code: first 3 letters most important

2.4 GHz Dual Handset Cordless Telephone Answering System 2255 with Caller ID/Call Waiting

SD Rack. DiGiCo SD Rack. User Manual B - August

Setup guide. point to point wall plate extenders

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

ORDER DIRECTLY TODAY AT: or CALL TOLL FREE Foglio di Istruzioni Owner s manual IMPERIAL. GR 0035 Xenon 4000

Your Phone This section introduces you to the hardware of the device.

Defibtech DDU-100 Semi-Automatic External Defibrillator

Disturbance Recoder SPCR 8C27. Product Guide

PIX-10 Electronic Time Recorder User s Guide

CONTENTS. Zulu User Guide 3

High Temperature InfraRed Thermometer with Laser Pointer

Mounting and operating instructions. Surface-mounted hands-free feature home station

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

JESTER OPERATING MANUAL

PHOENIX CONTACT Features

Installation Instructions. Thermo Call TC3

FSLIMRF

TFM GSMRoute BRI. Quick Installation Guide

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

Installation Guide for Hive Active Heating

User Manual GSM Alarm System. All rights reserved by Delta Security Co., Ltd

Autodialler. Installation & Programming Guide HYL004. Please read these instructions before you start the installation. Installation.

Redundancy Module QUINT-DIODE/40

Ericsson W25. Mobile Networks. Quick Installation Guide

MCR1900 Media Converter 19-Slot Chassis

The Foundation User Manual LED Battery Slim Par Fixture (RGBA, DMX 7Ch/4CH)

Product information and manual for SensLab BT-Adapter (Model type: BT060721) for wireless data transfer of measurement data of Lactate Scout-handheld

MOUNTING AND OPERATING INSTRUCTIONS

Media Gateway Hardware

Operating instructions for built-in electronic timers with Day and Week programms. Series 884

Installation and user guide. Lifeline GSM D C

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Fire suppression system for engine compartments USER MANUAL

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

Transcription:

Cardiac Rhythm Management External Devices Quick Reference Guide Reocor D External Pacemaker

Quick Reference Guide Reocor D Note: Before using Reocor D, read its user manual, including all safety instructions. Insert battery Reocor D must be operated with a 9 V battery, international code IEC 6LR61. The battery compartment (12) is located on the right side of the device, and it is opened by pushing the blue slider upwards and pulling out the drawer towards the right. To protect the battery poles, a rubber plug can be put on the new battery. Remove it before you insert the new battery. The preferred pole orientation is marked in the battery compartment. When inserting the new battery you only need to ensure that the battery poles point to the middle of the housing. The position of the plus and minus pole can be selected freely. Insert the new battery with the bottom down first (without the battery poles) into the battery compartment. Close the drawer and press the blue slider down until it snaps in place with an audible click.

Optical and acoustic signals Flashing LED "Low battery" (7) Meaning: ERI has been reached. Error correction: Replace the battery; about 36 hours of service time remain. Fast sequence of sounds Meaning: Impedance outside of the tolerance range. Error correction: Check whether all connectors are securely plugged in. Check whether the leads have the desired position. Acoustic signal for 2 s Meaning: A pulse amplitude of < 1 V or a frequency of > 180 ppm is set. Error correction: Check whether the set values are suitable for the patient. Acoustic signal and flashing of the Pace and Sense LEDs Meaning: High rate protection has been triggered or self-test failed. Error correction: Turn the device off and return it to BIOTRONIK. Use and operation The operating panel of the device is accessible when the transparent protective cover is pushed down all the way. During use of Reocor D, the heart rate of the patient is to be monitored with an ECG monitor with alarm function. During use of Reocor D, the protective cover must be completely closed to prevent inadvertent resetting of the programmed parameters.

The operation of Reocor D is identical for all operating modes. The operating steps should be carried out in the following order: (1) Prepare patient: Place the leads but do not connect them to the pacemaker yet. (2) Set the pacing rate with the Rate control dial. (3) Set the AV delay with the AV delay control dial. (4) Set the pacing amplitude for atrium with the Atrium Ampl. control dial. (5) Set the pacing amplitude for ventricle with the Ventricle Ampl. control dial. (6) Select the pacing mode with the dial Mode. The device will be activated at the same time. (7) If the Low battery LED flashes, the battery needs to be exchanged. It is possible to exchange a battery while Reocor D is in use. The device remains ready for use for at least 30 s at ambient temperature (20 ±2 C) when the battery is removed. (8) Connect leads, the yellow Atrium Pace and Ventricle Pace LEDs will flash in synchrony with the atrial and ventricular pacing pulses. (9) Set the sensitivity for atrium with the Atrium Sens. control dial so that the green Atrium Sense LED flashes in synchrony with each sensed atrial event. (10) Set the sensitivity for ventricle with the Ventricle Sens. control dial so that the green Ventricle Sense LED flashes in synchrony with each sensed ventricular event. (11) Monitor the ECG of the patient and adjust amplitude and/or sensitivity, if necessary.

0,1 40 30 60 80 100 120 140 170 200 250 0,5 1 2 3 5 7 10 12 17 0,5 0,1 1 2 3 5 7 10 12 17 100 60 200 300 400 500 600 700 800 1000 20 17 14 11 8 5 4 7 0, 3 2 1 10 7 5 3 2 1 0,5 0,3 0,2 75 400 350 250 200 180 100 50 25 15 VVT V00 VVI VDD D00 DDD Low battery DIFF.- INDIFF.+ (6) (3) (9) (7) (8) (8) (5) (12) (4) (2) (10)

Lead connection Reocor D has four connector ports for direct connection of leads with touch-proof 2-mm plugs: atrial channel A+/A-, ventricular channel V+/V-. To connect cables with Redel plugs, the Redel adapter must be fitted on the correct side and screwed together. The Redel adapter is fitted to the correct side if it can be screwed on to Reocor D. Patient cable PK-67-L (2.6 m) and PK-67-S (0.8 m) differ only in length. On the Reocor D side you have a Redel plug (use the Redel adapter) and on the patient side a connection for the adapter PA-1-B, PA-2 and PA-4 and for the single-use cable PK-155. Patient cable PK-175 with four screw terminals for temporary leads on the patient side and Redel plug on the Reocor side (use Redel adapter). Patient cable PK-83-B for single-chamber pacing with two screw terminals for temporary leads on the patient side and Redel plug on the Reocor side (use Redel adapter). Temporary leads that are connected with the PK-83-B are connected to the ventricular channel of Reocor D. Patient cable PK-141 with four alligator clips on the patient side and Redel plug on the Reocor side (use Redel adapter).

Redel plug PK-67-L/S Alligator clips Redel plug PK-175 Redel plug PK-83-B Redel plug PK-141

BIOTRONIK SE & Co. KG All rights reserved. Specifications are subject to modification, revision and improvement. 9 12-D-18 Revision: D (2012-04-13) BIOTRONIK SE & Co. KG Woermannkehre 1 12359 Berlin Germany Tel. +49 (0) 68905-0 Fax +49 (0) 6852804 sales@biotronik.com www.biotronik.com