Pacers use a 5-letter code: first 3 letters most important
|
|
|
- Ashley Lawson
- 9 years ago
- Views:
Transcription
1 PACEMAKERS 2
2 Pacemakers: Nomenclature Pacers use a 5-letter code: first 3 letters most important t First Letter: Chamber Paced A= Atrium V= Ventricle D= Dual (A+V) 2nd Letter: Chamber Sensed A= Atrium V= Ventricle D= Dual (A+V) O= None 3rd Letter: Response after Sensing: I = Pacing Inhibited T= Pacing Triggered D= Dual (I+T) O= None 4th Letter: Programmability P = Rate & Output M = Multiprogramable C = Communicating R = Rate adaptive O = None 5th Letter: Arrhythmia Control P = pacing S= shock D= Dual (P+S) O = None
3 Pacemaker Terminology Rate: the heart rate at which the pacemaker will pace. Standby rate: the lowest rate at which the pacemaker will pace. Capture: depolarization i and resultant contraction of the myocardium in response to a pacemaker generated electrical stimulus. Sensing: Dependent on the amplitude, slew rate and signal frequency, it describes the pacemakers ability to recognize a native electrical l signal.
4 Pacemaker Terminology Sensitivity: the minimum intracardiac signaling required by the pacemaker to initiate a pacemaker response. Threshold: minimum quantity, of either amplitude (milliamperes, volts) pulse duration (milliseconds), charge (coulombs) or energy (Joules) produced d by the pacemaker that persistently produces an action potential and myocardial contraction.
5 Pacemaker Terminology.. Mode: indicates pacemaker capabilities: fixed rate or demand. Fixed rate: pacemaker is one that fires at a specific preset rate, regardless of the patient's own heart rate. Demand: that is, only when the patient's heart rate falls below a preset value. Pulse interval: the total time of the AV and VA intervals. number of pulses per minute. Hysteresis: an intentional prolonged pulse interval in order to allow the generation of a spontaneous-intrinsic electrical depolarization event.
6 Pacemaker Terminology Atrioventricular (AV) interval (ie AV delay): described for dual-chamber pacemakers. The equivalent to a native PR interval. Represents the time (msec) between an atrial event and a paced ventricular event. Time that the pacemaker discerns whether or not to pace dependant upon sensing a native R wave. Allows the ventricle time to fill following an atrial contraction. Ventriculoatrial (VA) interval: described for dual- chamber pacemakers. Represents the time (msec) between a ventricular event and a paced atrial event.
7 Ventricular Synchronous Demand Pacemaker Hz, Centered at 30 Hz Detection sensitivity :1 2 mv Cardiac Signal Range: 1-30 mv Pulse Generator: functions Pacing and Sensing T 1 : limits pulse delivery rate in presence of EMI and prevents retriggering of astable MV Free running MV provides fixed rate mode with an interval of T 2 via o/p circuit O/P pulses of length T 3 synchronous with i/p signals that falls outside of sensing refractory period T1 are delivered to stimulating electrodes
8
9 Commercial pacemakers Use Defibrillation ill protection ti circuit it One diode or 2 back-to-back placed diodes (symmetrical) Symmetrical diodes minimize high-level, high-frequency, pulsed EMI artifacts raise noise detection threshold Output of pacemaker Constant current 8-10 ma with 1.0 to 1.2ms Constant Voltage 5V with ms Pulse rates bpm Refractory period: ms Unipolar or Bipolar electrodes are used Unipolar Bipolar
10 Programmable pacemaker External Internal External Pacemaker Pulsating Electromagnet Rate and width adjustable Reed Switch Heart Pulse Generator Methods of transmitting information Magnetic Radio-frequency waves Acoustic-ultrasonic pressure waves
11 Programmable pacemaker Main Requirement: immune to accidental programming Information to be sent is coded pacemaker decodes after receiving Consists of 3 systems System 1 Main timing function System 2 Sensing and signal discriminating function System 3 Programmable control
12 System 1 Timing Control Circuit Rate Limiter Output Circuit Vario function Battery test Reed Switch System 3 Crystal System 2 Data validate Width Rate RP HYST Amplitude Programmable Control Circuit Sensitivity Stimulate Electrode Sense Comparator Amplifier R.F. Filter Indifferent Electrode
13 Detection System 2 Signal from electrode High frequency filtered by RF filter Selectively amplified depending on sensitivity level Resultant signal compared with preset value at comparator Abs. Magnitude greater than preset enable an i/p signal g g p /p g to be fed to timing control circuit Signals below preset value ignore
14 Operation System 1 Normal Operating Conditions i Timing control circuit periodically triggers o/p circuit to send stimulation pulses of programmed pulse width and amplitude Period b/w 2 pulses checked by rate limiter Any component failure rate is limited to <180 bpm If inhibit signal from system 2 timing controls checks with programmed refractory period Within refractory period ignore Outside refractory period 0 hysteresis - Reset timing control inhibit o/p circuit Hysteresis reset timing control with period of escape before next stimulation = programmed basic level + hysteresis period
15 Programming System 3 Reed switch receives programming signals Feeds these signals to data validate Data validate checks if reed switch was closed for a minimum period of 300 ms Checks for speed of arrival of signals and executes code validation check When all checks are satisfied, new code is stored in programmable control circuit Parameters programmed: rate, pulse width and amplitude, sensitivity, refractory period and hysteresis Measurements taken at 37C with 500 resistance Program contained in 20-bit command code in addition to parameters contains, mode of operation, identification and check codes
16 Rete responsive Pacemakers When SA node is diseased HR cannot be increased in response to metabolic demands Synchronous pacemakers cannot replicate functions of heart during stressful activities like exercise. Sensor ph, Respiratory rate, Vibration/ motion Blood temperature QT interval Controller circuit Control Algorithm Pulse generator Lead Wire and electrode system
17 Power sources Mercury Batteries Used by first American Pacemaker Mercury zinc oxide with 1200mAh Produces 1.35 V Biological Power Sources Galvanic Cells using body fluids Failure due to dendritic mercury growth, zinc oxide migration, leaky separators and corroded wells Eventually become permanently electrically isolated Nuclear Batteries Lithium-iodine Cells
18 Nuclear Batteries Used Plutonium 238 with half-life of 87 years Energy liberated by decay of 1g of Pu238 with a power density of 0.56 W/g is 780kWh With 1% efficiency for only pulse power 20 mg of With 1% efficiency, for only pulse power, 20 mg of Pu will be required.
19 Lithium-iodine iodine Cells Most commonly used because it offers long battery life It is solid-state device consisting of metallic Lithium anode and molecular iodine bonded in complex form o an organic carrier as cathode 2Li + I 2 = 2LiI + e - Lithium has highest electrochemical equivalent of alkali metal - Most energetic anode material Ideal for use in high energy density batteries Develops 2.8 V which can be stepped up to 5 V
20 Cardiac pacemaker electrodes (a) Bipolar intraluminal electrode. (b) Intramyocardial electrode (formerly used).
21 Active and passive fixation mechanisms of various types for endocardial and epicardial pacing leads
22 Unipolar and bipolar implementations of both J-shaped and nonpreshaped leads. All models have distal cathode. Bipolar designs typically have a ring anode proximal mm on the lead.
23 Pacing voltage loss at the myocardium electrode interface is reduced by implementing a porous as opposed to relatively smooth tipped electrode. Decrease in voltage loss is largely contributed to by decreased electrode polarization associated with increased active surface area.
24 Electrode body Porous, platinum coated titanium tip Silicon rubber plug (impregnated with DSP steroid) Cross-sectional view of a steroid-eluting intracardiac electrode (Medtronic CapSure electrode, model 4003). Note silicone rubber plug with impregnated steroid DSP. Steroid elutes through the porous tip into surrounding tissue, thus reducing inflammation.
Pulse Output. Michael K. Laudon
11 Pulse Output Michael K. Laudon The function of the output circuit is to deliver periodic voltage pulses to the heart muscle. High standards of quality and durability are required for the design and
Basics of Pacing. Ruth Hickling, RN-BSN Tasha Conley, RN-BSN
Basics of Pacing Ruth Hickling, RN-BSN Tasha Conley, RN-BSN The Cardiac Conduction System Cardiac Conduction System Review Normal Conduction Conduction QRS QRS Complex Complex RR PP ST ST segment segment
«Δυσλειτουργία βηματοδότη. Πως μπορούμε να την εκτιμήσουμε στο ιατρείο.» Koσσυβάκης Χάρης Καρδιολογικό Τμήμα Γ.Ν.Α. «Γ. ΓΕΝΝΗΜΑΤΑΣ
«Δυσλειτουργία βηματοδότη. Πως μπορούμε να την εκτιμήσουμε στο ιατρείο.» Koσσυβάκης Χάρης Καρδιολογικό Τμήμα Γ.Ν.Α. «Γ. ΓΕΝΝΗΜΑΤΑΣ Diagnostic tools History: symptoms, physical examination 12 leads ECG,
Introduction to Electrophysiology. Wm. W. Barrington, MD, FACC University of Pittsburgh Medical Center
Introduction to Electrophysiology Wm. W. Barrington, MD, FACC University of Pittsburgh Medical Center Objectives Indications for EP Study How do we do the study Normal recordings Abnormal Recordings Limitations
Equine Cardiovascular Disease
Equine Cardiovascular Disease 3 rd most common cause of poor performance in athletic horses (after musculoskeletal and respiratory) Cardiac abnormalities are rare Clinical Signs: Poor performance/exercise
Electrophysiology Introduction, Basics. The Myocardial Cell. Chapter 1- Thaler
Electrophysiology Introduction, Basics Chapter 1- Thaler The Myocardial Cell Syncytium Resting state Polarized negative Membrane pump Depolarization fundamental electrical event of the heart Repolarization
Electrocardiography I Laboratory
Introduction The body relies on the heart to circulate blood throughout the body. The heart is responsible for pumping oxygenated blood from the lungs out to the body through the arteries and also circulating
Pulse Width Modulation (PWM) LED Dimmer Circuit. Using a 555 Timer Chip
Pulse Width Modulation (PWM) LED Dimmer Circuit Using a 555 Timer Chip Goals of Experiment Demonstrate the operation of a simple PWM circuit that can be used to adjust the intensity of a green LED by varying
Efficient Heart Rate Monitoring
Efficient Heart Rate Monitoring By Sanjeev Kumar, Applications Engineer, Cypress Semiconductor Corp. Heart rate is one of the most frequently measured parameters of the human body and plays an important
Management of Pacing Wires After Cardiac Surgery
Management of Pacing Wires After Cardiac Surgery David E. Lizotte, Jr. PA C, MPAS, FAPACVS President, Association of Physician Assistants in Cardiovascular Surgery Conflicts: None Indications 2008 Journal
INTRODUCTORY GUIDE TO IDENTIFYING ECG IRREGULARITIES
INTRODUCTORY GUIDE TO IDENTIFYING ECG IRREGULARITIES NOTICE: This is an introductory guide for a user to understand basic ECG tracings and parameters. The guide will allow user to identify some of the
Understanding the Electrocardiogram. David C. Kasarda M.D. FAAEM St. Luke s Hospital, Bethlehem
Understanding the Electrocardiogram David C. Kasarda M.D. FAAEM St. Luke s Hospital, Bethlehem Overview 1. History 2. Review of the conduction system 3. EKG: Electrodes and Leads 4. EKG: Waves and Intervals
Introduction to Electrocardiography. The Genesis and Conduction of Cardiac Rhythm
Introduction to Electrocardiography Munther K. Homoud, M.D. Tufts-New England Medical Center Spring 2008 The Genesis and Conduction of Cardiac Rhythm Automaticity is the cardiac cell s ability to spontaneously
Dual Chamber Temporary Pacemaker
5388 Dual Chamber Temporary Pacemaker Technical Manual Caution: Federal Law (USA) restricts this device to sale by c or on the order of a physician. 0123 MODEL 5388 0 Technical Manual 0 Dual Chamber Temporary
MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.
Exam Name MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question. 1) What term is used to refer to the process of electrical discharge and the flow of electrical
QRS Complexes. Fast & Easy ECGs A Self-Paced Learning Program
6 QRS Complexes Fast & Easy ECGs A Self-Paced Learning Program Q I A ECG Waveforms Normally the heart beats in a regular, rhythmic fashion producing a P wave, QRS complex and T wave I Step 4 of ECG Analysis
By the end of this continuing education module the clinician will be able to:
EKG Interpretation WWW.RN.ORG Reviewed March, 2015, Expires April, 2017 Provider Information and Specifics available on our Website Unauthorized Distribution Prohibited 2015 RN.ORG, S.A., RN.ORG, LLC Developed
CCAD Training Manual. Cardiac Rhythm Management (CRM)
CCAD Training Manual Cardiac Rhythm Management (CRM) Version 1.0 A D Cunningham 19/3/2008 Introduction This manual is intended to assist users of the Notes Client version of the CCAD Cardiac Rhythm Management
Exchange solutes and water with cells of the body
Chapter 8 Heart and Blood Vessels Three Types of Blood Vessels Transport Blood Arteries Carry blood away from the heart Transport blood under high pressure Capillaries Exchange solutes and water with cells
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
reduction ore = metal oxides metal oxidation
Cathodic Protection and Interferences René Gregoor Madrid, June 18 th and 19 th 2009 1 Cathodic protection and interferences Corrosion Cathodic protection Protection criterion ON potential measurements
Kit 106. 50 Watt Audio Amplifier
Kit 106 50 Watt Audio Amplifier T his kit is based on an amazing IC amplifier module from ST Electronics, the TDA7294 It is intended for use as a high quality audio class AB amplifier in hi-fi applications
Tachyarrhythmias (fast heart rhythms)
Patient information factsheet Tachyarrhythmias (fast heart rhythms) The normal electrical system of the heart The heart has its own electrical conduction system. The conduction system sends signals throughout
ELECTROCARDIOGRAPHY (I) THE GENESIS OF THE ELECTROCARDIOGRAM
ELECTROCARDIOGRAPHY (I) THE GENESIS OF THE ELECTROCARDIOGRAM Scridon Alina, Șerban Răzvan Constantin 1. Definition The electrocardiogram (abbreviated ECG or EKG) represents the graphic recording of electrical
Basic principles of pacing
CHAPTER 1 Basic principles of pacing Malcolm Kirk The aim of this chapter is to give sufficient background and information about cardiac pacemakers to allow interpretation of electrocardiograms (ECGs)
Activity 5: The Action Potential: Measuring Its Absolute and Relative Refractory Periods. 250 20 Yes. 125 20 Yes. 60 20 No. 60 25 No.
3: Neurophysiology of Nerve Impulses (Part 2) Activity 5: The Action Potential: Measuring Its Absolute and Relative Refractory Periods Interval between stimuli Stimulus voltage (mv) Second action potential?
PSIO 603/BME 511 1 Dr. Janis Burt February 19, 2007 MRB 422; 626-6833 [email protected]. MUSCLE EXCITABILITY - Ventricle
SIO 63/BME 511 1 Dr. Janis Burt February 19, 27 MRB 422; 626-6833 MUSCLE EXCITABILITY - Ventricle READING: Boron & Boulpaep pages: 483-57 OBJECTIVES: 1. Draw a picture of the heart in vertical (frontal
DIODE CIRCUITS LABORATORY. Fig. 8.1a Fig 8.1b
DIODE CIRCUITS LABORATORY A solid state diode consists of a junction of either dissimilar semiconductors (pn junction diode) or a metal and a semiconductor (Schottky barrier diode). Regardless of the type,
BSNL TTA Question Paper-Instruments and Measurement Specialization 2007
BSNL TTA Question Paper-Instruments and Measurement Specialization 2007 (1) Instrument is a device for determining (a) the magnitude of a quantity (b) the physics of a variable (c) either of the above
AC Direct Off-Line Power Supplies
AC Direct Off-Line Power Supplies r Introduction Many DC power supplies found in electronic systems, including those in this Tech School, rectify the 120 volts available at an electric outlet. The initial
RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
Preset Counter signo 721
Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage
Series 427. 1/16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS
Series 427 1/16 DIN Multi-Mode Bar Graph Display Timer PRODUCT HIGHLIGHTS Digital Setting with 0.1% Accuracy Unique LED Bargraph Indicates Time Cycle in 20% Increments 8 Field Selectable Modes of Operation
Pacemakers 12/04. Pacemakers. 1. What is a pacemaker?
Pacemakers 12/04 1-What is a pacemaker? 2- What does intrinsic mean? 3- How exactly do pacemakers work on the heart? 4- What are the parts of a pacemaker? 5- Are there different kinds of pacemakers? 6-
Adding Heart to Your Technology
RMCM-01 Heart Rate Receiver Component Product code #: 39025074 KEY FEATURES High Filtering Unit Designed to work well on constant noise fields SMD component: To be installed as a standard component to
HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS
ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS USER MANUAL USER MANUAL ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS INTRODUCTION The (HA-841K) is a complete
TRANSPORT OF DANGEROUS GOODS
Recommendations on the TRANSPORT OF DANGEROUS GOODS Manual of Tests and Criteria Fifth revised edition Amendment 1 UNITED NATIONS SECTION 38 38.3 Amend to read as follows: "38.3 Lithium metal and lithium
Pacemaker Counter and Histogram Operation and Interpretation. Percentage of total count. Figure 2. Detailed ALTRUA Paced and Sensed Event Counters
A Closer Look SUMMARY This article provides information regarding the operation and interpretation of Event Counters and Histograms available in ALTRUA, INSIGNIA, PULSAR MAX II, and DISCOVERY II pacemakers.
Programmable Single-/Dual-/Triple- Tone Gong SAE 800
Programmable Single-/Dual-/Triple- Tone Gong Preliminary Data SAE 800 Bipolar IC Features Supply voltage range 2.8 V to 18 V Few external components (no electrolytic capacitor) 1 tone, 2 tones, 3 tones
MADP-000504-10720T. Non Magnetic MELF PIN Diode
MADP-54-172T Features High Power Handling Low Loss / Low Distortion Leadless Low Inductance MELF Package Non-Magnetic Surface Mountable RoHS Compliant MSL 1 Package Style 172 Dot Denotes Cathode Description
The full wave rectifier consists of two diodes and a resister as shown in Figure
The Full-Wave Rectifier The full wave rectifier consists of two diodes and a resister as shown in Figure The transformer has a centre-tapped secondary winding. This secondary winding has a lead attached
Electrodes placed on the body s surface can detect electrical activity, APPLIED ANATOMY AND PHYSIOLOGY. Circulatory system
4 READING AND INTERPRETING THE ELECTROCARDIOGRAM Electrodes placed on the body s surface can detect electrical activity, which occurs in the heart. The recording of these electrical events comprises an
Instruction Manual Service Program ULTRA-PROG-IR
Instruction Manual Service Program ULTRA-PROG-IR Parameterizing Software for Ultrasonic Sensors with Infrared Interface Contents 1 Installation of the Software ULTRA-PROG-IR... 4 1.1 System Requirements...
Welcome to Vibrationdata
Welcome to Vibrationdata Acoustics Shock Vibration Signal Processing December 2004 Newsletter Ni hao Feature Articles One of my goals is to measure a wide variety of oscillating signals. In some sense,
Proximity Switches RS (Reed Switch)
Proximity Switches RS (Reed Switch) General Pneumatic systems can often be combined with electric control circuits. The position of the piston in the cylinder can then be sensed by means of a proximity
A Practical Guide to Free Energy Devices
A Practical Guide to Free Energy Devices Part PatD9: Last updated: 28th January 2006 Author: Patrick J. Kelly Please note that this is a re-worded excerpt from this patent. If the content interests you,
The D.C Power Supply
The D.C Power Supply Voltage Step Down Electrical Isolation Converts Bipolar signal to Unipolar Half or Full wave Smoothes the voltage variation Still has some ripples Reduce ripples Stabilize the output
Special Topics in Security and Privacy of Medical Information. Reminders. Medical device security. Sujata Garera
Special Topics in Security and Privacy of Medical Information Sujata Garera Reminders Assignment due today Project part 1 due on next Tuesday Assignment 2 will be online today evening 2nd Discussion session
A Practical Guide to Free Energy Devices
A Practical Guide to Free Energy Devices Electrolysis Patents No. 16: Last updated: 30th September 2006 Author: Patrick J. Kelly The major difficulty in using Stan s low-current Water Fuel Cell (recently
Tire pressure monitoring
Application Note AN601 Tire pressure monitoring 1 Purpose This document is intended to give hints on how to use the Intersema pressure sensors in a low cost tire pressure monitoring system (TPMS). 2 Introduction
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
Charged cable event. 1 Goal of the ongoing investigation. 2 Energy sources for the CDE. Content
Charged cable event David Pommerenke, [email protected], 916 785 4550 Last update: Feb.23, 2001 Content Goal Energy sources, which may lead to CDE. Complexity of the different discharge modes. Possible
MSFET 3332. MICROSENS Miniature ph Sensor Module
Product Data Sheet MSFET 3332 MICROSENS Miniature ph Sensor Module Ta2O5 gate Ion Sensitive Field Effect transistor (ISFET) The MSFET3332 ph sensor module comprises a ph-isfet sensing element, an integrated
4 SENSORS. Example. A force of 1 N is exerted on a PZT5A disc of diameter 10 mm and thickness 1 mm. The resulting mechanical stress is:
4 SENSORS The modern technical world demands the availability of sensors to measure and convert a variety of physical quantities into electrical signals. These signals can then be fed into data processing
ACLS Chapter 3 Rhythm Review Instructor Lesson Plan to Accompany ACLS Study Guide 3e
ACLS Chapter 3 Rhythm Review Lesson Plan Required reading before this lesson: ACLS Study Guide 3e Textbook Chapter 3 Materials needed: Multimedia projector, computer, ACLS Chapter 3 Recommended minimum
ECG Signal Analysis Using Wavelet Transforms
Bulg. J. Phys. 35 (2008) 68 77 ECG Signal Analysis Using Wavelet Transforms C. Saritha, V. Sukanya, Y. Narasimha Murthy Department of Physics and Electronics, S.S.B.N. COLLEGE (Autonomous) Anantapur 515
UN Manual of Tests and Criteria, Sub-section 38.3, Amendments to the 5 th edition, effective 2014 January 1 st
1 UN Manual of Tests and Criteria, Sub-section 38.3, Amendments to the 5 th edition, effective 2014 January 1 st 38.3 Lithium metal and lithium ion batteries 38.3.1 Purpose This section presents the procedures
css Custom Silicon Solutions, Inc.
css Custom Silicon Solutions, Inc. CSS555(C) CSS555/ PART DESCRIPTION The CSS555 is a micro-power version of the popular 555 Timer IC. It is pin-for-pin compatible with the standard 555 timer and features
IEC 1000-4-2 ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays
IEC 00-4-2 ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays Application Note July 1999 AN9612.2 Author: Wayne Austin The SP720, SP721, SP723, and SP724 are protection
Section Four: Pulmonary Artery Waveform Interpretation
Section Four: Pulmonary Artery Waveform Interpretation All hemodynamic pressures and waveforms are generated by pressure changes in the heart caused by myocardial contraction (systole) and relaxation/filling
Reocor D External Pacemaker
Cardiac Rhythm Management External Devices Quick Reference Guide Reocor D External Pacemaker Quick Reference Guide Reocor D Note: Before using Reocor D, read its user manual, including all safety instructions.
Micro-Step Driving for Stepper Motors: A Case Study
Micro-Step Driving for Stepper Motors: A Case Study N. Sedaghati-Mokhtari Graduate Student, School of ECE, University of Tehran, Tehran, Iran n.sedaghati @ece.ut.ac.ir Abstract: In this paper, a case study
Evaluation copy. Analyzing the Heart with EKG. Computer
Analyzing the Heart with EKG Computer An electrocardiogram (ECG or EKG) is a graphical recording of the electrical events occurring within the heart. In a healthy heart there is a natural pacemaker in
Ameritron ATP-102 Tuning Pulser II
Ameritron ATP-102 The Ameritron ATP-102 relieves temperature related stress on amplifiers, tuners, and dummy loads while allowing proper system adjustments. It allows amplifiers to be properly adjusted
EXPERIMENT #9 CORROSION OF METALS
EXPERIMENT #9 CORROSION OF METALS Objective The objective of this experiment is to measure the corrosion rate of two different metals and to show the effectiveness of the use of inhibitors to protect metals
LM139/LM239/LM339 A Quad of Independently Functioning Comparators
LM139/LM239/LM339 A Quad of Independently Functioning Comparators INTRODUCTION The LM139/LM239/LM339 family of devices is a monolithic quad of independently functioning comparators designed to meet the
Grounding Demystified
Grounding Demystified 3-1 Importance Of Grounding Techniques 45 40 35 30 25 20 15 10 5 0 Grounding 42% Case 22% Cable 18% Percent Used Filter 12% PCB 6% Grounding 42% Case Shield 22% Cable Shielding 18%
13. Diode Rectifiers, Filters, and Power Supplies
1 13. Diode Rectifiers, Filters, and Power Supplies Introduction A power supply takes Alternating Current or A.C. power from your electric utility (Con Edison) and converts the A.C. electrical current
PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features
Features Applications The PMP 4000 Series provides a complete range of high level voltage output pressure transducers offering advanced levels of measurement accuracy, stability and flexibility from a
CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR)
CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR) Fig1. CPTR SMART CONTROL PRECISION CUSTOMIZED MANUAL OR AUTO SCR OR DIODE DRY TYPE SWITCH MODE DRY TYPE SCR OR DIODE OIL TYPE 1 INDEX PAGE 1. Cover 2. Index
TEA1024/ TEA1124. Zero Voltage Switch with Fixed Ramp. Description. Features. Block Diagram
Zero Voltage Switch with Fixed Ramp TEA04/ TEA4 Description The monolithic integrated bipolar circuit, TEA04/ TEA4 is a zero voltage switch for triac control in domestic equipments. It offers not only
Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43
Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented
"($!$* -44 5 6 7.89 .#/ @9019 =3 5.# 19 = 77##.#2 19 79A951 88 "#$%!&#$'$()(!* "!$& %$!$*%!&& +", !"#$$"!"" %&!'""$&(&! )*""! %$"'""+,($" -. *""!
-.#/ @9019 =3 5.# 19 = 77##.#2 19 79A951 88!"#$$"!"" %&!'""$&(&! )*""! %$"'""+,($" -. *""!! /01 234#55 65571 50087( *""!! *5571 *579$+):#;$+#" *579#-;#-( *5791 1' 971 1' 951 1' 1 "#?=" 3 08!08&1@@
Tutorial. replace them with cell-phone operated module. The advantages of a cell-phone operated bot are:-
Tutorial Overview: The basic aim of the project is to find an alternative to the usual RF circuits that are seen so frequently and replace them with cell-phone operated module. The advantages of a cell-phone
Contents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
OPERATIONAL AMPLIFIERS. o/p
OPERATIONAL AMPLIFIERS 1. If the input to the circuit of figure is a sine wave the output will be i/p o/p a. A half wave rectified sine wave b. A fullwave rectified sine wave c. A triangular wave d. A
Functions of Blood System. Blood Cells
Functions of Blood System Transport: to and from tissue cells Nutrients to cells: amino acids, glucose, vitamins, minerals, lipids (as lipoproteins). Oxygen: by red blood corpuscles (oxyhaemoglobin - 4
DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155
DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 Technical information Version: 07.14 General Function The speed sensors family DSD.70 are suitable for generating
The heart then repolarises (or refills) in time for the next stimulus and contraction.
Atrial Fibrillation BRIEFLY, HOW DOES THE HEART PUMP? The heart has four chambers. The upper chambers are called atria. One chamber is called an atrium, and the lower chambers are called ventricles. In
Ignition Alert Anti-Theft Security System for Motorbikes with Remote Control Amit Yadav, Anushri Jha, Neelesh Gupta amitrinku007@yahoo.
Ignition Alert Anti-Theft Security System for Motorbikes with Remote Control Amit Yadav, Anushri Jha, Neelesh Gupta [email protected] Abstract There are many vehicle security system are available
FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5
T5 TC-L PCA T5 BASIC lp Y II, 1 80 W BASIC T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal,
Pressure Transducer to ADC Application
Application Report SLOA05 October 2000 Pressure Transducer to ADC Application John Bishop ABSTRACT Advanced Analog Products/OpAmp Applications A range of bridgetype transducers can measure numerous process
For a complete explanation of all the functions and configurations available please refer to the SC6006: Manual of operation.
PRELIMINARY TECHNICAL INFORMATION Three-phase Digital SCR Firing Board HIGHLIGHTS - Up to 480 V AC input supply voltage - Up to 700 V AC sync input - DSP controlled - Digital or analog input signaling
The P Wave: Indicator of Atrial Enlargement
Marquette University e-publications@marquette Physician Assistant Studies Faculty Research and Publications Health Sciences, College of 8-12-2010 The P Wave: Indicator of Atrial Enlargement Patrick Loftis
1. Learn about the 555 timer integrated circuit and applications 2. Apply the 555 timer to build an infrared (IR) transmitter and receiver
Electronics Exercise 2: The 555 Timer and its Applications Mechatronics Instructional Laboratory Woodruff School of Mechanical Engineering Georgia Institute of Technology Lab Director: I. Charles Ume,
Multifunction Digital Timer
Multifunction Digital Timer 1/16 DIN Timer with Easy-to-use Functions Nine output modes accommodate a wide variety of applications. All parameters set by scroll-through menus accessed from the front panel.
MODEL 2202IQ (1991-MSRP $549.00)
F O R T H E L O V E O F M U S I C F O R T H E L O V E O F M U S I C MODEL 2202IQ (1991-MSRP $549.00) OWNER'S MANUAL AND INSTALLATION GUIDE INTRODUCTION Congratulations on your decision to purchase a LINEAR
Talon and Talon SR User Manual
Talon and Talon SR User Manual Brushed DC motor controller Version 1.3 Cross the Road Electronics, LLC www.crosstheroadelectronics.com Cross The Road Electronics, LLC Page 1 4/2/2013 Device Overview Clear,
Activitity (of a radioisotope): The number of nuclei in a sample undergoing radioactive decay in each second. It is commonly expressed in curies
Activitity (of a radioisotope): The number of nuclei in a sample undergoing radioactive decay in each second. It is commonly expressed in curies (Ci), where 1 Ci = 3.7x10 10 disintegrations per second.
Series and Parallel Circuits
Direct Current (DC) Direct current (DC) is the unidirectional flow of electric charge. The term DC is used to refer to power systems that use refer to the constant (not changing with time), mean (average)
1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.
1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter
The Do s and Don ts of Pressure Transducers
The Do s and Don ts of Pressure Transducers ABSTRACT When specifying a pressure transducer for a process measurement, a number of items have to be considered. Some of the more important ones are discussed
NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter
NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter Description: The NTE2053 is a CMOS 8 bit successive approximation Analog to Digital converter in a 20 Lead DIP type package which uses a differential
Application Note AN-1068 reva
Application Note AN-1068 reva Considerations for Designs Using Radiation-Hardened Solid State Relays By Alan Tasker Table of Contents Introduction Page Overview...1 The Contact...1 Actuation...1 The IR
NI USB-5681 RF Power Meter Specifications
NI USB-568 RF Power Meter Specifications General This document lists specifications for the NI USB-568 RF power meter. Minimum or maximum specifications are warranted under the following conditions: hour