Motor circuit-breakers



Similar documents
Electrical auxiliaries 0 For i DPN (DPN), C60 and C120

Thermal-Magnetic Circuit Breaker M1-..

Electronic overload relay EF19 and EF45

Circuit Breakers. Next Generation of Protection Capabilities

D-Line Contactors, Overload Relays and Accessories

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Safety detection solutions

PSR The compact range Description

8146/5 Series Breaker Panelboards

Electronic overload relay EF65, EF96 and EF146

R.C.C.B. s two-pole LEXIC

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Pendant control stations 6

MOTOR PROTECTIVE DEVICES

Plug and Socket Devices CES 63 A Series 8579

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Series 8146/5-V37 and Series 8150/5-V37

Manual Motor Starter MS 116 up to 16 A Technical Data

Safety automation solutions

Wiring diagrams. Compact NSX. Contents

SENTRON Switching and Protection Devices Air Circuit Breakers

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

RM4TG20 three-phase network control relay RM4-T - range V

Phone: Fax: Web: info@clrwtr.com

Spare parts Catalogue

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Circuit Breakers. NRC Series. NRC Series

3RV Motor Starter Protectors up to 100 A

Control Panel Technical Guide

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Vario-Series Accessories

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

Tmax MCCBs. Molded case circuit breakers. Tmax

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)

Plug and Socket Devices SolConeX 16 A Series 8570

Voltage Regulator SPAU 341 C. Product Guide

NEXT SOLUTION EXPERT SOLUTION EXCELLENT SOLUTION. Super Solution

Technicaldata General

5SV Residual Current Protective Devices

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Breaking and protection devices

IZM ACB/Circuit-breakers. Robust safety. Extract from Main Catalogue HPL2010 IZM26 Circuit-breakers IN26 Switch-disconnectors

Mureva Assembly surface mounted wiring devices

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Sentron Series Circuit Breakers

HERZ-Thermal Actuators

Technical catalogue. Modular DIN rail components Installation contactors

THERMAL RELAYS, MOTORSTARTERS

Givare NC-SRS 280 och 880

Catalog January. Heavy industrial power applications Motor contactors and starters

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

ACS-30-EU-EMDR-10-MOD

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

Manual motor starter MS116

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

3AH5 Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

Number 1 in efficiency

Safety dialogue solutions

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

General Informations 2 Technical data 3 Basic designs 4-8

49 Series - Relay interface modules A. Features

know-how Giant in distributing electricity for industry Prisma GK

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN Annex M

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog

Bulletin 1489 Circuit Breakers. Selection Guide

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Maximum Demand Control

Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors. Technical Data

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Technical catalog. FORMULA UL New low voltage molded case circuit breakers up to 250A. Power and productivity for a better world TM

BETA Protecting SITOR Semiconductor Fuses

Quick Connect. quick - simple - efficient.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

ASSEMBLED SOCKET-COMBINATIONS

Low Voltage. EasyPact CVS. Moulded-case circuit breakers and switch-disconnectors from 100 to 630 A. Catalogue 2011

Securing your electrical installations Prisma,

Cross-beam scanning system to detect slim objects. 100 mm in

Current transformers (CT) & Shunts

NM8, NM8S NM8, NM8S. Moulded Case Circuit Breakers. 3. Type designation. 4. Product overview N M 8 / / /

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

SMS 4 / SMS 5 safety mat Product information

INDUSTRIAL CONTROLS. APEM, PO BOX 8288, HAVERHILL, MA USA TOLL FREE: (877) FAX: (781)

Unified requirements for systems with voltages above 1 kv up to 15 kv

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

48 SERIES Relay interface modules 10 A

A product made in Australia. Insulated Conductor Rail ACTIV-8 PLUS

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Motor protection plugs

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

WE-350 Series ¼ Turn Electric Actuator

Transcription:

Thermal-magnetic motor circuit-breakers type GV2-M GV2-M Thermal-magnetic motor circuit-breakers GV2-M Pushbutton control Standard power ratings Setting Magnetic Thermal Reference Weight of 3-phase motors range of tripping current 50/60 Hz in category AC-3 thermal current Ithe in 220 400 trips Id ± 20 % GV2-Miii 230 V V 440 V 500 V 690 V enclosure kw kw kw kw kw A A A kg 0. 0.6.5 0.6 GV2-M0 0.260 0.06 0.06 0.6 0.25 2.4 0.25 GV2-M02 0.260 0.06 0.09 0.09 0.25 0.40 5 0.40 GV2-M03 0.260 0.2 0.2 0.8 0.37 0.40 0.63 8 0.63 GV2-M04 0.260 0.8 0.09 0.25 0.25 0.37 0.55 0.63 3 GV2-M05 0.260 0.2 0.37 0.37 0.8 0.37 0.37 0.37 0.75.6 22.5.6 GV2-M06 0.260 0.25 0.55 0.55 0.55. 0.75 0.37 0.75 0.75..5.6 2.5 33.5 2.5 GV2-M07 0.260. 0.55..5.5 2.2 2.5 4 5 4 GV2-M08 0.260 0.75.5 2.2 3. 2.2 2.2 3 4 4 6.3 78 6.3 GV2-M0 0.260 3.5 3 4 4 5.5 6 0 38 9 GV2-M4 0.260 2.2 4 5.5 7.5 2.2 5.5 5.5 7.5 9 9 4 70 3 GV2-M6 0.260 3 7.5 4 7.5 7.5 9 5 3 8 223 7 GV2-M20 0.260 9 5.5 9 8.5 7 23 327 2 GV2-M2 0.260 5.5 5 22 20 25 327 23 GV2-M22 0.260 7.5 5 5 8.5 22 24 32 46 30 GV2-M32 0.260 Thermal-magnetic motor circuit-breakers GV2-M with built-in auxiliary contact block With instantaneous auxiliary contact block : - GV2-AE, add suffix AETQ to the motor circuit-breaker reference selected above. Example : GV2-M0 becomes GV2-M0AETQ. - GV2-AE, add suffix AETQ to the motor circuit-breaker reference selected above. Example : GV2-M0 becomes GV2-M0AETQ. - GV2-AN, add suffix ANTQ to the motor circuit-breaker reference selected above. Example : GV2-M0 becomes GV2-M0ANTQ. These thermal-magnetic motor circuit-breakers with built-in contact block are sold in lots of 20 parts in a single pack. GV2-M GV2-AX GV2-AD, AM, AN, AU, AS, AX GV2-AE Block GV2-AD, AM, AN Block GV2-AU, AS, AX 5 50/60 89 X X 6 44 6 9,3 9,3 8 66 8() X Electrical clearance 40 mm for Ue 690 V () Maximum Mounting of GV2-M On panel with adaptor plate GV2-AF02 On pre-slotted mounting plate On mounting rail DZ5-MB20 On mm " rail AM-PA GV2-AF02 c 78.5 on AM-DP200 ( x 7.5) AF-EA4 c 86 on AM-DE200, ED200 ( x 5) 4,2 DZ5-MB20 DZ5-ME8 50/60 50 60 0 c 80 5 /84 Te

Thermal-magnetic motor circuit-breakers type GV2-P Thermal-magnetic motor circuit-breakers GV2-P Control by rotary handle Standard power ratings Setting Magnetic Reference Weight of 3-phase motors range of tripping 50/60 Hz in category AC-3 thermal current 220 400 trips Id ± 20 % 230 V V 440 V 500 V 690 V kw kw kw kw kw A A kg GV2-P 0. 0.6.5 GV2-P0 0.0 0.06 0.06 0.6 0.25 2.4 GV2-P02 0.0 0.06 0.09 0.09 0.25 0.40 5 GV2-P03 0.0 0.2 0.2 0.8 0.37 0.40 0.63 8 GV2-P04 0.0 0.8 0.09 0.25 0.25 0.37 0.55 0.63 3 GV2-P05 0.0 0.2 0.37 0.37 0.8 0.37 0.37 0.37 0.75.6 22.5 GV2-P06 0.0 0.25 0.55 0.55 0.55. 0.75 0.37 0.75 0.75..5.6 2.5 33.5 GV2-P07 0.0. 0.55..5.5 2.2 2.5 4 5 GV2-P08 0.0 0.75.5 2.2 3. 2.2 2.2 3 4 4 6.3 78 GV2-P0 0.0 3.5 3 4 4 5.5 6 0 38 GV2-P4 0.0 2.2 4 5.5 7.5 2.2 5.5 5.5 7.5 9 9 4 70 GV2-P6 0.0 3 7.5 4 7.5 7.5 9 5 3 8 223 GV2-P20 0.0 9 5.5 9 8.5 7 23 327 GV2-P2 0.0 5.5 5 22 20 25 327 GV2-P22 0.0 GV2-P GV2-AD, AM, AN, AU, AS, GV2-AK00 Block GV2-AD, AM, AN 4 Block GV2-AU, AS X 98 9,3 9,3 8() 8 5 Ø5,5 84 84 05±5 55 89 6 32 5 26 50 82 X2 X2 40 mm X Electrical clearance 40 mm for Ue V, or 80 mm for Ue 440 V, or 20 mm for Ue 500 and 690 V Mounting of GV2-P On panel On pre-slotted mounting plate Adaptor plate GK2-AF0 On mm " mounting rail AM-PA ED200 ( x 5) AF-EA4 06 3,5 3,5 24 9,5 54 Te /85

GV2-V02 GV-L3 GV2-AK00 GV2-AX GV2-M GV2-M, GV2-RT GV2-AD GV2-AM GV2-AU GV2-P GV2-AM GV2-AS GV2-AE, AE20 GV2-AE GV2-AE GV2-AN GV2-AN /86 Te

Illustrations : page /86 Dimensions : pages /84 and /85 Thermal-magnetic motor circuit-breakers types GV2-M, GV2-RT and GV2-P Accessories Contact blocks (5) Description Mounting Contact types Sold in Unit Weight lots of reference kg Instantaneous Front () N/O or N/C (2) 0 GV2-AE 0.05 auxiliary ( block per N/O + N/C 0 GV2-AE 0.020 contacts breaker) N/O + N/O 0 GV2-AE20 0.020 Side (up to 2 blocks N/O + N/C GV2-AN 0.050 on LH side of breaker) N/O + N/O GV2-AN20 0.050 Fault Instantaneous Fault Side (3) N/O + N/O GV2-AD00 0.055 signalling ( block N/O + N/C GV2-AD00 0.055 contact + on LH instantaneous side of N/C + N/O GV2-AD00 0.055 auxiliary contact breaker) N/C + N/C GV2-AD00 0.055 Short-circuit Side C/O GV2-AM 0.0 signalling ( block on LH common contact side of breaker) point Electric trips Mounting Type Voltage Reference Weight kg Side Undervoltage 0 5 V 50 Hz GV2-AU5 0.05 ( block on trip 60 Hz GV2-AU6 0.05 RH side of 220 240 V 50 Hz GV2-AU225 0.05 breaker) 60 Hz GV2-AU226 0.05 380 400 V 50 Hz GV2-AU385 0.05 60 Hz GV2-AU386 0.05 440 V 50 Hz GV2-AU 0.05 440 V 60 Hz GV2-AU385 0.05 500 V 50 Hz GV2-AU505 0.05 600 V 60 Hz GV2-AU505 0.05 Add-on contact blocks Shunt 0 5 V 50 Hz GV2-AS5 0.05 trip 60 Hz GV2-AS6 0.05 220 240 V 50 Hz GV2-AS225 0.05 60 Hz GV2-AS226 0.05 380 400 V 50 Hz GV2-AS385 0.05 60 Hz GV2-AS386 0.05 440 V 50 Hz GV2-AS 0.05 440 V 60 Hz GV2-AS385 0.05 500 V 50 Hz GV2-AS505 0.05 600 V 60 Hz GV2-AS606 0.05 Undervoltage 0 5 V 50 Hz GV2-AX5 0.0 trip 60 Hz GV2-AX6 0.0 INRS (4) 220 240 V 50 Hz GV2-AX225 0.0 60 Hz GV2-AX226 0.0 380 400 V 50 Hz GV2-AX385 0.0 60 Hz GV2-AX386 0.0 V 50Hz GV2-AX 0.0 Description Mounting Operation Sold in Unit Weight lots of reference kg Visible Front () 3-pole on incoming GV2-AK00 0.50 isolation ( block per side of GV2-P motor block breaker) circuit-breaker 00 ka limiter At top GV-L3 0.30 Sealing kit For GV2-M Front 0 GV2-V02 0.00 () Mounting of a GV2-AE contact block or a GV2-AK00 visible isolation block on GV2-P. (2) Choice of N/C or N/O contact operation depending on which way round the reversible block is mounted. (3) The GV2-AD is always mounted next to the circuit-breaker. (4) Safety device for dangerous machines conforming to INRS and VDE 03. Can only be mounted on GV2-M. (5) Maximum of 2 contact blocks on left hand side of breaker. Te /87

GV2-G4 GV-G09 GV2-G4 GV2-G254 GV-G0 GV2-G05 LA9-E07 GK2-AF0 GV2-GA0 GV2-AF0 GV-G02 GV2-AF02 GV2-AP0 2 TRIP. RESET GV2-V03 O /88 Te

Thermal-magnetic motor circuit-breakers types GV2-M and GV2-P Accessories Illustrations : page /88 Mounting accessories Description Application Sold in Unit Weight lots of reference kg Motor starter With 3-pole connection for GK2-AF0 0.20 adaptor plate mounting of a GV2 and an LC-D09 to D25 contactor Adaptor plate For screw fixing of a GV2-M 0 GV2-AF02 0.02 7.5 mm height To allow GV2-M and 0 GV-F03 0.003 compensation plate GV2-L/P to be mounted on a common busbar Combination block Between GV2-M and 0 GV2-AF0 0.020 LC-K or LP-K contactor Cabling accessories Description Application Pitch Reference Weight mm kg Sets of 3-pole, 2 tap-offs GV2-G2 0.036 63 A busbars 54 GV-G254 0.038 72 GV2-G272 0.042 3 tap-offs 54 GV2-G4 0.060 4 tap-offs GV2-G4 0.077 54 GV-G4 0.085 72 GV2-G472 0.094 5 tap-offs 54 GV2-G554 0.00 Description Application Sold in Unit Weight lots of reference kg Protective end cover For unused busbar outlets 5 GV-G0 0.005 Terminal blocks for supply Connection from the top GV-G09 0.040 to one or more GV-G0i Can be fitted with a GV2-G05 0.5 or GV2-G0i busbar sets GV-L3 current limiter Flexible 3-pole connection Centre distance between 0 GV-G02 0.03 For connecting a GV2 mounting rails: to an LC-D09 D25 00 20 mm contactor Marking accessories Description Application Sold in Unit Weight lots of reference kg Clip-in marker holders For GV2-M (8 x 7 mm) 00 LA9-D90 0.00 (supplied with each For GV2-P (8 x 22 mm) 00 LA9-D92 0.00 motor circuit-breaker) Padlockable external operator Description Reference Weight kg For GV2-P Black handle, blue legend plate GV2-AP0 0.200 (50 to 290 mm) Red handle, yellow legend plate GV2-AP02 0.200 Padlocking device For all GV2 devices 6 padlocks, Ø 6 mm shank max. GV2-V03 0.30 (padlock not supplied) GV2-AF0 GV2-M + GV-L3 (current limiter) 7.5 mm height compensation plate GV2-M + K contactor combination GV-F03 X 52 77 X 89 40 29 3 39 79 X 0 mm for Ue 230 V or 30 mm for 230 V < Ue 690 V Te /89

GV2- MC GV2-V0 GV2-K0 GV2-MP GV2-E0 GV2-CP GV2-SN /90 Te

Thermal-magnetic motor circuit-breakers types GV2-M and GV2-P Illustrations : page /90 Enclosures for thermal-magnetic motor circuit-breakers GV2-M Application Type Degree of protection Reference Weight of enclosure kg For motor circuit-breakers Surface IP 4 GV2-MC0 0.290 with or without accessories mounting, (maximum of accessory double on right and left for GV2-MCi insulated with IP 55 GV2-MC02 0.300 and GV2-MP0 or MP02, protective accessory only on right conductor. for GV2-MP03 and GV2-MP04) Sealable IP 55 for GV2-MC03 0.300 cover. temperature < + 5 C Flush IP 4 (front face) GV2-MP0 0.5 mounting with IP 4 GV2-MP03 0.5 protective (reduced flush mounting) conductor IP 55 (front face) GV2-MP02 0.30 Front plate IP 55 GV2-MP04 0.30 (reduced flush mounting) Application Degree of protection Reference Weight kg For direct control, IP 55 GV2-CP2 0.800 through a panel, of a GV2-M mounted in an enclosure Accessories common to all enclosures (to be ordered separately) Description Sold in Unit Weight lots of reference kg Padlocking device () GV2-V0 0.075 for GV2-M operator (padlocking is only possible in the O position) Mushroom head Spring return GV2-K0 0.052 stop pushbutton () Ø 40 mm, red Latching Key release GV2-K02 0.095 (key n 5) Turn to GV2-K03 0.052 release Sealing kit For IP 55 0 GV2-E0 0.02 enclosures and front plate IP 55 0 GV2-E02 0.02 for temperature < + 5 C Neutral link 0 GV2-N0 0.030 Description Voltage Colour Sold in Reference Weight V lots of kg Neon indicator light 0 Green 0 GV2-SN3 0.09 Red 0 GV2-SN4 0.09 Orange 0 GV2-SN5 0.09 Clear 0 GV2-SN7 0.09 220/240 Green 0 GV2-SN23 0.09 Red 0 GV2-SN24 0.09 Orange 0 GV2-SN25 0.09 Clear 0 GV2-SN27 0.09 380/440 Green 0 GV2-SN33 0.09 Red 0 GV2-SN34 0.09 Orange 0 GV2-SN 0.09 Clear 0 GV2-SN37 0.09 () Supplied with IP 55 sealing kit. Te /9

Thermal-magnetic motor circuit-breakers types GV2-M and GV2-P Dimensions, mounting : pages : 909/2 to 909/5 Surface mounting enclosure GV2-MC0i Front plate GV2-CP2 47 () 2xØ5,3x6,3 30 2 x Ø3,3 Ø7 62 2,5 8 33 84 93 2...4 76 93 7,5 () 4 knock-outs for 6 mm plastic cable glands or n 6 conduit Flush mounting enclosure GV2-MP0i (bracket cut-out) GV2-MP0i GV2-MP0, MP02 GV2-MP03, MP04 a 40 27 7 33 9,5 2...6 a 93,5 06,5 7 93 6,5 GV2- a a MP0, MP02 7 MP03, MP04 7 86 /92 Te

Thermal-magnetic motor circuit-breakers types GV2-M and GV2-P Dimensions, mounting : pages /84 to /90 Sets of busbars GV-G07, GV2-G0, GV2-G03, with terminal block GV2-G05 3 a l p 63 8 l p GV-G07 (4 x 54 mm) 206 54 GV2-G0 (4 x mm) 79 GV2-G03 (4 x mm) 260 72 a No. of tap-offs 5 6 7 8 GV-G07 260 34 368 422 GV2-G0 224 269 34 9 GV2-G03 332 404 476 548 Sets of busbars GVi-G0i with terminal block GV-G09 Sets of busbars GV-G08, GV2-G02, GV2-G04 GV-G09 l 30 l GV-G08 (2 x 54 mm) 98 GV2-G02 (2 x mm) 89 GV2-G04 (2 x 72 mm) 6 Set of busbars GV2-G07 Set of busbars GV2-G06 260 52 Te /93

Magnetic motor circuit-breakers type GV2-L Magnetic motor circuit-breakers GV2-L Rotary handle Standard power ratings Magnetic Tripping Use in Reference Weight of 3-phase motors protection current association 50/60 Hz in category AC-3 rating Id ± 20 % with thermal 220 400 overload 230 V V 440 V 500 V 690 V relay kw kw kw kw kw A A kg GV2-L 0.06 0.09 0.09 0.4 5 LR2-D303 GV2-L03 0.330 0.2 0.2 0.8 0.37 0.63 8 LR2-D304 GV2-L04 0.330 0.8 0.09 0.25 0.25 0.37 0.55 3 LR2-D305 GV2-L05 0.330 0.2 0.37 0.37 0.8 0.37 0.37 0.37 0.75.6 22.5 LR2-D306 GV2-L06 0.330 0.25 0.55 0.55 0.55. 0.75 0.37 0.75 0.75..5 2.5 33.5 LR2-D307 GV2-L07 0.330.. 0.55..5.5 2.2 4 5 LR2-D308 GV2-L08 0.330 0.75.5 2.2 3. 2.2 2.2 3 4 6.3 78 LR2-D30 GV2-L0 0.330 3.5 3 4 5.5 0 38 LR2-D32 GV2-L4 0.330 2.2 4 4 5.5 7.5 0 38 LR2-D34 GV2-L4 0.330 2.2 5.5 5.5 7.5 9 4 70 LR2-D36 GV2-L6 0.330 3 4 7.5 7.5 7.5 8 223 LR2-D32 GV2-L20 0.330 9 9 5 5.5 9 8.5 25 327 LR2-D322 GV2-L22 0.330 5 22 GV2-L GV2-AD, AM, AN, AU, AS, GV2-AK00 4 Block GV2-AD, AM, AN Block GV2-AU, AS 89 X 98 6 32 5 26 50 82 X2 9,3 9,3 8 () 8 X2 40 mm X Electrical clearance 40 mm for Ue V, or 80 mm for Ue 440 V, or 20 mm for Ue 500 and 690 V () Maximum Mounting of GV2-L On panel On pre-slotted mounting plate Adaptor plate GK2-AF0 On mounting rail AM-DE200, AM-PA AM-ED200 ( x 5) AF-EA4 84 84 55 5 Ø5,5 05±5 06 3,5 3,5 24 9,5 54 /94 Te

Magnetic motor circuit-breakers type GV2-LE GV2-LE Magnetic motor circuit-breakers GV2-LE Rocker lever Standard power ratings Magnetic Tripping Use in Reference Weight of 3-phase motors protection current association 50/60 Hz in category AC-3 rating Id ± 20 % with thermal 220 400 overload 230 V V 440 V 500 V 690 V relay kw kw kw kw kw A A kg 0.06 0.06 0.4 5 LR2-K0302 GV2-LE03 0.330 0.09 0.4 5 LR2-K0303 GV2-LE03 0.330 0.06 0.09 0.2 0.4 5 LR2-K0304 GV2-LE03 0.330 0.2 0.37 0.63 8 LR2-K0304 GV2-LE04 0.330 0.8 0.8 0.63 8 LR2-K0305 GV2-LE04 0.330 0.09 0.25 0.55 3 LR2-K0305 GV2-LE05 0.330 0.2 0.25 0.37 0.37 0.75 3 LR2-K0306 GV2-LE05 0.330 0.37 0.8 0.37 0.37 0.37 0.75.6 22.5 LR2-K0306 GV2-LE06 0.330 0.25 0.55 0.55 0.55..6 22.5 LR2-K0307 GV2-LE06 0.330 0.75 0.75 2.5 33.5 LR2-K0307 GV2-LE07 0.330 0.37 0.75.. 2.5 33.5 LR2-K0308 GV2-LE07 0.330. 0.55.5.5.5 3 4 5 LR2-K030 GV2-LE08 0.330 0.75 2.2 4 5 LR2-K032 GV2-LE08 0.330. 2.2 2.2 3 4 6.3 78 LR2-K032 GV2-LE0 0.330 3 6.3 78 LR2-K034 GV2-LE0 0.330.5 3 4 4 0 38 LR2-K034 GV2-LE4 0.330 4 0 38 LR2-K036 GV2-LE4 0.330 2.2 4 4 5.5 7.5 0 38 LR2-D34 GV2-LE4 0.330 2.2 5.5 5.5 7.5 9 4 70 LR2-D36 GV2-LE6 0.330 3 4 7.5 7.5 7.5 8 223 LR2-D32 GV2-LE20 0.330 9 9 5 5.5 9 8.5 25 327 LR2-D322 GV2-LE22 0.330 5 22 7.5 5 5 8.5 22 46 LR2-D23 GV-LE32 0.260 GV2-AD, AM, AN, AU, AS GV2-AE On pre-slotted mounting plate On mounting rails DZ5-MB20 OAM-PA Block GV2-AD, AM, AN Block GV2-AU, AS 5 GV2-AF02 AF-EA4 DZ5-MB20 DZ5-ME8 0 50/60 50 60 9,3 9,3 8 8 () 5 Te /95

GV2-AK00 GV2-AU GV2-LE GV2-AD GV2-AM GV2-AS GV2-L GV2-AM GV2-AE, AE20 GV2-AE GV2-AE GV2-AN GV2-AN /96 Te

Magnetic motor circuit-breakers types GV2-L and GV2-LE Accessories Illustrations : page /94 Dimensions : pages /92 and /93 Contact blocks (4) Description Mounting Contact types Sold in Unit Weight lots of reference kg Instantaneous Front () N/O or N/C (2) 0 GV2-AE 0.05 auxiliary ( block per N/O + N/C 0 GV2-AE 0.020 contacts breaker) N/O + N/O 0 GV2-AE20 0.020 Side (up to 2 blocks N/O + N/C GV2-AN 0.050 on LH side of N/O + N/O GV2-AN20 0.050 breaker) Fault Instantaneous Fault Side (3) N/O + N/O GV2-AD00 0.055 signalling ( block N/O + N/C GV2-AD00 0.055 contact + on LH side instantaneous of breaker) N/C + N/O GV2-AD00 0.055 auxiliary contact N/C + N/C GV2-AD00 0.055 Short-circuit Side C/O GV2-AM 0.0 signalling ( block on LH common contact side of breaker) point Electric trips Mounting Type Voltage Reference Weight kg Side Undervoltage 0 27 V 50 Hz GV2-AU5 0.05 ( block on trip 60 Hz GV2-AU6 0.05 RH side of 220 240 V 50 Hz GV2-AU225 0.05 breaker) 60 Hz GV2-AU226 0.05 380 400 V 50 Hz GV2-AU385 0.05 60 Hz GV2-AU386 0.05 440 V 50 Hz GV2-AU 0.05 440 V 60 Hz GV2-AU385 0.05 500 V 50 Hz GV2-AU505 0.05 600 V 60 Hz GV2-AU505 0.05 Add-on contact blocks Overvoltage 0 5 V 50 Hz GV2-AS5 0.05 trip 60 Hz GV2-AS6 0.05 220 240 V 50 Hz GV2-AS225 0.05 60 Hz GV2-AS226 0.05 380 400 V 50 Hz GV2-AS385 0.05 60 Hz GV2-AS386 0.05 440 V 50 Hz GV2-AS 0.05 440 V 60 Hz GV2-AS385 0.05 500 V 50 Hz GV2-AS505 0.05 600 V 60 Hz GV2-AS505 0.05 Description Mounting Operation Reference Weight kg Visible Front () 3-pole visible isolation GV2-AK00 0.50 isolation ( block per on incoming side of block breaker) GV2-L motor circuit-breaker () Mounting of a GV2-AE contact block or a GV2-AK00 visible isolation block on GV2-L. (2) Choice of N/C or N/O contact operation depending on which way round the reversible block is mounted. (3) The GV2-AD is always mounted next to the circuit-breaker. (4) Maximum of 2 contact blocks on left hand side of breaker. Te /97