SOFTLINK 300. CPU Specifications. Reference Manual



Similar documents
Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP

CPUs - CPU PN/DP

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL E04

FAQ Communication over IE


SIMATIC S7-300, CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 128 KBYTE WORKING MEMORY 2

Training document for the company-wide automation solution Totally Integrated Automation (T I A) MODULE A5. PLC-Simulation with S7-PLCSIM

CPU PN/DP. Function

SIMATIC NET. S7-CPs for PROFIBUS. CP Basic. Manual Part B3

Data sheet SLIO CPU 015 (015-CEFPR00)

1 Application Description Objective Goals... 3

The CP FO provides access to different communication services of the PROFIBUS bus system:

CP Page 1342 Mar 2008 Siemens ITS

The CP provides access to different communication services of the PROFIBUS bus system:

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE E05

Service & Support. How can you establish a connection between an S PLC and SIMATIC NET OPC? S PLC, SIMATIC NET OPC.

FAQ about Drive Technology

How-To-Do. Hardware Configuration SLIO CPU 014

6ES BE01-0AB0 6ES BE01-0AB0

Continuous PROFIBUS PA Instruments and Step 7. Configuring a Siemens Continuous Level PROFIBUS PA device in a S7-300 or S7-400 PLC

WinCC. Communication Manual. Manual 2. This manual is part of the documentation package with the order number: 6AV6392-1CA05-0AB0 C79000-G8276-C156-01

S7-1500/S7-1500F Technical Data

Service & Support. How can you establish a connection between a S PLC and SIMATIC NET OPC? S PLC, SIMATIC NET OPC.

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

6ES7314-6CG03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

PROCESS AUTOMATION PLANNING AND INTEGRATION INFORMATION LB8106* Integration in Siemens SIMATIC PCS 7

TECHNICAL NOTE TNOI34

1 Application Description System Topology Hardware and Software Requirements... 3

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

FAQ Communication over IE

SIMATIC Expert Communication Connecting S7-400H to PC Station (WinCC)

s Preface SIMATIC Configuring Hardware and Communication Connections with STEP 7 Contents Basics of Configuring Hardware with STEP 7 1

HTML Code Generator V 1.0 For Simatic IT Modules CP IT, IT, IT

SIMATIC. STEP 7 From S5 to S7. Preface, Contents Part 1: Planning Your Conversion. Introduction. Hardware. Converter Manual.

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

S7 for Windows S7-300/400

Ethernet Module Manual

Applications & Tools. Configuration of Messages and Alarms in WinCC (TIA Portal) WinCC (TIA Portal) Application description December 2012

PROFINET IRT: Getting Started with The Siemens CPU 315 PLC

Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

ABB industrial drives. Quick start-up guide Drive Manager for SIMATIC

Cover sheet PROFINET IO. SIMATIC MV440 Code Reading System. FAQ February Service & Support. Answers for industry.

GW-7552 PRIFIBUS/MODBUS GATEWAY

Profinet to EDV111 Series LED Signs Siemens Function Block Software Manual

Redundant PROFIBUS DP network with S7-400H System and Ponto PO5063V5 Remote

Application Note Profinet Modules

The goal is to program the PLC and HMI to count with the following behaviors:

S and STEP 7 Basic V10.5

S7-400H SIMATIC. Fault-tolerant systems S7-400H. Preface 1 Fault-tolerant automation systems. S7-400H setup options 3.

Siemens S7 PLC and FC 300 Profibus

Cover sheet. Reading out the topology data of a PROFINET IO system SFB52 "RDREC" FAQ September Service & Support. Answers for industry.

CMC-PD01 PROFIBUS DP Slave Communication Card Operation Manual

Configuring the WT-4 for Upload to a Computer (Infrastructure Mode)

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE C2. High Level Programming with S7-SCL

Installing PowerLink on Windows 7 64-bit

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

Turbo 85 Mbps Powerline Ethernet Adapter Model # APL8512. User s Manual. Ver. 1A

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

ENTBUS PLUS SOFTWARE FOR ENERGY MONITORING AND RECORDING INSTALLATION AND OPERATING MANUAL

Point of view HDMI Smart TV dongle Mini RF Keyboard

S7 OPC Server Tutorial

SIMATIC NET. S7-CPs for Industrial Ethernet. CP Lean. Manual Part B8. Version 1 or higher (Firmware Version V1.0) for SIMATIC S7-300 / C7-300

Using a Modbus TCP to Profibus PA Gateway by IFAK system

Start-up of IVI-KHD2-4HRX, IVI-KHA6-4HRX at S7-300 V1.1. Table of Contents TABLE OF CONTENTS... 1

How-To-Do. EtherCAT Communication with CPU 300S

How to use KEPServerEX OPC Server (Kepware) with iologik 4000 (Modbus TCP/IP NA-4010 and Modbus Serial NA-4020/NA-4021)

SIMATIC S /30 SIPLUS digital modules 5/30 SIPLUS SM 322 digital output module. 5/31 Analog modules 5/31 SM 331 analog input module

Commissioning IDENTControl Compact IC-KP2-2HB17-2V1D Profinet Protocol with a Siemens S7 PLC

EXPERIMENT 2 TRAFFIC LIGHT CONTROL SYSTEM FOR AN INTERSECTION USING S7-300 PLC

Beckhoff TwinCAT. Configuring the TwinCAT I/O System

S7-1500/S7-1500F Technical Data

Software redundancy for SIMATIC S7 SIMATIC. S7-300/S7-400 Software redundancy for SIMATIC S7. Contents 1

SIMATIC S Workshop. Unrestricted / Siemens AG All Rights Reserved.

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide

Programmable controllers. Programming devices, software

SIMATIC PCS 7. SIMATIC Maintenance Station PDM A stand-alone Solution. Siemens AG All Rights Reserved.

SIMATIC S /2 Introduction. 4/4 Central processing units. 4/34 Digital modules. 4/44 Analog modules. 4/55 F digital /analog modules

Application about Communication

6AV3617-1JC30-0AX1. Type of voltage. UPS connectable (serial) Backup battery. minimum backup duration Memory. Flash / RAM.

STEP 7 MICRO/WIN TUTORIAL. Step-1: How to open Step 7 Micro/WIN

Applications & Tools. Configuration and Diagnostics of a PROFINET IO System. PROFINET IO Configuration Example. Application Description January 2010

WinCON8000-R2/R8. Hardware User s Manual

Firmware Update Instruction Manual

Using the WAGO PROFINET Coupler as Remote I/O with a Siemens S7 PLC

Cover sheet. Consistent Data. PROFIBUS DP and PROFINET IO. FAQ September Service & Support. Answers for industry.

QuickPanel Control DeviceNet Master Communications Card (IC754DVNM01) Quick Start Guide. Thursday September 20, 2007

SIMATIC. S7-300 Programmable Controller Installation and Hardware. Preface, Contents. Product Overview 1. Mechanical Configuration 2

SIMATIC. Automation System S7-400H Fault-tolerant Systems. Preface, Contents. Fault-Tolerant Programmable Logic Controllers 1

SoundLAB Software Download Software from the Bogen website:

Configuring the WT-4 for Upload to a Computer (Ad-hoc Mode)

Congratulations on your purchase of a BPM Microsystems device programmer. Your new device programmer was designe d to provid e years of suppor t for

SIMATIC. S7 300 PLC CPU 317T-2 DP: Controlling a virtual axis. Introduction. Preparation. Learning units 3. Further information 4.

Configuring the WT-4 for Upload to a Computer (Infrastructure Mode)

I.S. 1 remote I/O system Redundant coupling via PROFIBUS DP

1 How configure S7 PLC in the configuration tool

User Manual Revision English

Manual. VIPA WinNCS. Order no.: VIPA HB91E Rev. 04/03

EPICS using SLS s7plc driver

WUA Mbps Wireless USB Network Adapter

Transcription:

SOFTLINK 300 Reference Manual This manual is part of the documentation Package with the order number 300 314-1SL01 300 314-2DP01 300 315-2DP01 Edition 04/2011 i

Preface Purpose of the manual This manual gives you a brief overview of SOFTLINK 300 CPU in an S7-300. You can look up information on how to operate the system, its function and technical data of the CPUs. Essential know-how General knowledge of automation technology is required for comprehension of this Manual. You should also be acquainted with basic STEP 7 software. ii

Contents Preface... ii Hardware Configuration...1 1.1 Technical Data... 1 1.2 Expansion modules... 2 1.3 Backup battery... 2 1.4 Dimensioned Drawing... 3 Software Configuration... 4 2.1 Blocks... 4 2.1.2 Maximum of FB, FC, DB blocks...4 2.2 Hardware Configuration Settings... 5 2.2.1 Expansion Modules... 5 2.2.2 Choice for CPU...6 2.2.3 CPU as Slave...7 2.3 MMC Card... 13 Annex -- Compatible Module...16 Support & Service...17 iii

Hardware Configuration 1.1 Technical Data Order No. 300 314-1SL01 300 314-2DP01 300 315-2DP01 Electric Input Voltage DC 24V DC 24V DC 24V Current Consumption 1.2A 1.2A 1.2A Current supply 3.5A 3.5A 3.5A CPU Work memory 96KB 96KB 196KB Load memory 144KB 144KB 144KB Bit memory 8192 8192 8192 Total address space I/O 1024byte 1024byte 1024byte Timer/Counter 256 256 256 Blocks Processing time of bit/word Interface OB 1/10/20/35/40/80/82/ 85/86/100/121/122 FB:1024 FC:1024 DB:2047 OB 1/10/20/35/40/80/82/8 5/86/100/121/122 FB:1024 FC:1024 DB:2047 OB 1/10/20/35/40/80/82/8 5/86 /100/121/122 FB:1024 FC:1024 DB:2047 0.18/0.78us 0.18/0.78us 0.18/0.78us MPI & Profibus DP slave MPI & Profibus DP master MPI & Profibus DP master Module per rack 32 32 32 Profibus DP Slave Total address space I/O 64 Byte 64 Byte 64 Byte Transmission rate 9.6K to 12MB baud 9.6K to 12MB baud 9.6K to 12MB baud Master No. of slaves Max 125 Max 125 Total address space I/O 1024 Byte 1024 Byte Transmission rate 9.6K to 12MB baud 9.6K to 12MB baud 1

1.2 Expansion modules The CPUs support maximum 32 modules in one rack. According to the customized requirement, modules can be hung from No. 0 to 32. SOFTLINK 300 CPUs are compatible with Siemens S7-300, programmed in STEP 7. The solution to deal with maximum 32 modules can be found in 2.2 Hardware Configuration Settings in this manual. 1.3 Backup battery The built-in backup battery in the CPUs can realize the program and save parts of data for 14 days. 2

1.4 Dimensioned Drawing Front view Back view 3

Software Configuration 2.1 Blocks 2.1.1 OB Blocks THE OB blocks SOFTLINK 300 CPU supports include: OB 1/10/20/35/40/80/82/85/86/100/121/122. 2.1.2 Maximum of FB, FC, DB blocks FB 1024 FC 1024 DB 2047 4

2.2 Hardware Configuration Settings 2.2.1 Expansion Modules For the CPUs can realize maximum 32 modules in one rack without the need of IM360, IM361 or IM365, the hardware configuration(hwc) settings in STEP 7 is different from Siemens CPUs. The CPUs expand modules via virtual extension. The specific method is: When the expansion modules come to above 8 ones, we can add modules via IM360 or IM361 when programming. The corresponding numbers to add is as below. Numbers for Modules IM360 IM361 8-16 1 1 17-24 1 2 35-32 1 3 Notice If room limited, the CPUs support of the extension via IM360, IM361 and IM365. 5

2.2.2 Choice for CPU In hardware configuration settings in STEP 7, the choice for SOFTLINK CPU will be: 6ES7-315-2AF03-0AB0 V1.2 version 6

2.2.3 CPU as Slave GSD files will be needed to install when the CPU is used as a slave. After the installation of GSD files, the corresponding device icons will be found as below. 7

After the installation of GSD files, DP slave configuration can be proceeded. The specific method is showed below. 1. Set up DP master 1) Open master HWC window, insert a CPU in the rack, and set DP property. 2) Set up 2 DP nets via 'new' item in PROFIBUS Interface DP ParameterView. 3) Set proper baudrates for the 2 DP nets as required (both must be the same). 4) Click OK to finish the configuration. 8

2. Set up DP slave Open HWC slave window, and choose the other net different from master when setting CPU properties as below. 9

3. Insert CPU into the DP net Directly drag the device icons to the net or double-click them. Below shows the result. 10

4. Data Communication Configuration After inserting DP subnet to DP net, the communication channel between slaves and master is required, e.g. 8-byte input/ output data exchange between slaves and master. 1) Click device icons in DP subnet, and choose the byte as required as below. 11

2) Communication Configuration for slaves 1 Unfold config 'Properties' to set DP slave property. 2 Set up communication bytes between slaves and master via 'new' button. 3 Input address should be conformity with the corresponding output address in master, while the output address should be conformity with the corresponding input address in master. The config is completed when it is showed as below. 12

2.3 MMC Card The CPUs could save data for 14 days under power loss. You can save data for a longer time by other methods, e.g. CD, hard-disk or U-disk on PC. Here displays the method of MMC Card to save files. 1. Build a hold file 1) Build a hold file on PC. 2) Open the project needed to be saved, and choose 'Memory Card File' as below. 13

3)Build 2 hold files, named AutoLoad file and S7Prog file as showed below. 14

4) Copy and paste all the blocks files into the MMC card files and save them. 5) Build AutoLoad file with the same method. AutoLoad. wld & S7Prog. wld will appear in the corresponding files. You can copy them into MMC card via card reader. The files are saved completely. The files in MMC card will be saved forever(under normal operation). If MMC card is inserted before CPU is on power, it will proceed card reading operation automatically and upload the blocks files into CPU when on power. What we recommend is to extract MMC card. 15

Annex -- -- Compatible Module SOFTLINK 300 CPUs support all SOFTLINK 300 modules and some of Siemens modules. The ones do not support are showed as below. Order No. for Siemens Modules Description Support or not 6ES7 321-1BP00-0AA0 DI64 DC 24V NO 6ES7 321-7RD00-0AB0 DI4 NAMUR, EX NO 6ES7 321-7TH00-0AB0 DI16 NAMUR NO 6ES7 322-1BP00-0AA0 DO64 DC 24V NO 6ES7 322-1BP50-0AA0 DO64 DC 24V NO 6ES7 322-8BH00-0AB0 DO16 24V, Diag NO 6ES7 322-8BH01-0AB0 DO16 24V, Diag NO 6ES7 338-7XF00-0AB0 SM338 8 IQ-SENSE NO 6GK7 342-5DA02-0XE0 CP342-5 NO 6GK7 342-5DF00-0XE0 CP342-5 FO NO 6GK7 342-5FA01-0XE0 CP342-5 FMS NO All CP343-1 Ethernet modules NO 6ES7 353-1AH01-0AE0 FM353 STEPPER NO 6ES7 354-1AH01-0AE0 FM354 SERVO NO 6ES7 357-4AH01-0AE0 FM357 4AXIS Control NO 6ES7 352-5AH00-0AE0 FM352-5 NO 6ES7 352-5AH10-0AE0 FM352-5 NO 6ES7 355-0VH10-0AE0 FM355 C PID K-BUS NO 6ES7 355-1VH10-0AE0 FM355 S PID K-BUS NO 16

Support & Service Support Please contact our technical supports when questions arose. Email: support@softlink.cn Tel: +86-755-25336812 Fax: +86-755-25333788 Website: www.softlink.cn Service 24-month Warranty for SOFTLINK products Free training of operating guide for all products 17