SIMATIC S /30 SIPLUS digital modules 5/30 SIPLUS SM 322 digital output module. 5/31 Analog modules 5/31 SM 331 analog input module

Size: px
Start display at page:

Download "SIMATIC S7-300. 5/30 SIPLUS digital modules 5/30 SIPLUS SM 322 digital output module. 5/31 Analog modules 5/31 SM 331 analog input module"

Transcription

1 /2 Central processing units /2 Standard CPUs /2 CPU 312 /2 CPU 314 /2 CPU 31-2 DP /2 CPU 31-2 PN/DP /3 CPU PN/DP /17 Fail-safe CPUs /17 CPU 31F-2 DP /17 CPU 31F-2 PN/DP /18 CPU 317F-2 PN/DP /30 SIPLUS digital modules /30 SIPLUS SM 322 digital output module /31 Analog modules /31 SM 331 analog input module /34 F digital / analog modules /34 SM 326 F digital input module - Safety Integrated /36 SM 326 F digital output module - Safety Integrated /39 SIPLUS F digital-/analog modules /39 SIPLUS SM 326 F digital input module /40 SIPLUS SM 336 F analog input module /41 Function modules /41 IM 174 PROFIBUS module /44 SIPLUS SIWAREX U /4 Communication /4 SIPLUS CP 340 /46 CP 341 /48 SIPLUS CP 341 /49 SIPLUS CP Lean /0 CP ERPC /4 CP BACnet /7 CSM 377 unmanaged /9 Power supplies Brochures For brochures serving as selection guides for SIMATIC products refer to: printmaterial

2 Central processing units Siemens AG 2010 Standard CPUs Overview CPU 312 Overview CPU 31-2 DP The entry level CPU in Totally Integrated Automation (TIA) For smaller applications with moderate requirements for processing performance SIMATIC Micro Memory Card required for operation of CPU. The CPU with medium to large program memory and quantity structures for optional use of SIMATIC engineering tools High processing power in binary and floating-point arithmetic PROFIBUS DP master/slave interface For comprehensive I/O expansion For configuring distributed I/O structures SIMATIC Micro Memory Card required for operation of CPU. Overview CPU 314 Overview CPU 31-2 PN/DP For plants with medium requirements for program size High processing power in binary and floating-point arithmetic SIMATIC Micro Memory Card required for operation of CPU. The CPU with mid-range program memory and quantity frameworks High processing power in binary and floating-point arithmetic Used as central controller in production lines with central and distributed I/O Component Based Automation (CBA) on PROFINET PROFINET proxy for intelligent devices on PROFIBUS DP in Component Based Automation (CBA) PROFINET IO Controller for operating distributed I/O on PROFINET PROFINET interface with 2-port switch Combined MPI/PROFIBUS DP master/slave interface Isochronous mode on PROFIBUS SIMATIC Micro Memory Card required for operation of CPU. /2

3 Central processing units Overview CPU PN/DP Standard CPUs The CPU with a large program memory and quantity framework for demanding applications For cross-sector automation tasks in series machine, special machine and plant construction Used as central controller in production lines with central and distributed I/O High processing power in binary and floating-point arithmetic Distributed intelligence in Component Based Automation (CBA) on PROFINET PROFINET proxy for intelligent devices on PROFIBUS DP in Component Based Automation (CBA) PROFINET I/O Controller for operating distributed I/O on PROFINET PROFINET interface with 2-port switch Combined MPI/PROFIBUS DP master/slave interface For comprehensive I/O expansion For configuring distributed I/O structures Isochronous mode on PROFIBUS Optionally supports the use of SIMATIC engineering tools SIMATIC Micro Memory Card required for operation of CPU. Technical specifications 6ES AE14-6ES AG14-6ES7 31-2AH14-6ES7 31-2EH14-6ES EK14- Product-type designation CPU 312 CPU 314 CPU 31-2 DP CPU 31-2 PN/DP CPU PN/DP Product version associated programming package Supply voltages Rated value STEP 7 > V.4 + SP or STEP 7 as of V.2 + SP1 with HSP 176 STEP 7 > V.4 + SP or STEP 7 as of V.2 + SP1 with HSP 17 STEP 7 > V.4 + SP or STEP 7 as of V.2 + SP1 with HSP 177 STEP 7 > V.4 + SP or STEP 7 as of V.4 + SP4 with HSP V DC permissible range, lower limit (DC) permissible range, upper limit (DC) external protection for supply cables (recommendation) Current consumption Current consumption (rated value) Current consumption (in no-load operation), typ V 20.4 V 20.4 V 20.4 V 20.4 V 28.8 V 28.8 V 28.8 V 28.8 V 28.8 V Min. 2 A Min. 2 A Min. 2 A Min. 2 A Min. 2 A 60 ma 60 ma 80 ma 70 ma 70 ma 140 ma 140 ma 10 ma 10 ma 10 ma Inrush current, typ. 3. A 3. A 3. A 4 A 4 A I²t 1 A² s 1 A² s 1 A² s 1 A² s 1 A² s from supply voltage L+, 60 ma 60 ma 900 ma Power loss Power loss, typ. 4 W 4 W 4. W Memory Work memory integrated 32 Kibyte; For program and data 128 Kibyte; For program and data 26 Kibyte 384 Kibyte 1 Mbyte expandable STEP 7 > V.4 + SP or STEP 7 as of V.4 + SP4 with HSP 189 /3

4 Central processing units Siemens AG 2010 Standard CPUs Technical specifications (continued) 6ES AE14-6ES AG14-6ES7 31-2AH14-6ES7 31-2EH14-6ES EK14- Product-type designation CPU 312 CPU 314 CPU 31-2 DP CPU 31-2 PN/DP CPU PN/DP Work memory Size of retentive memory for retentive data blocks Load memory 32 Kibyte 64 Kibyte 128 Kibyte 128 Kibyte 26 Kibyte pluggable (MMC) pluggable (MMC), 8 Mbyte 8 Mbyte 8 Mbyte 8 Mbyte 8 Mbyte Backup present without battery CPU/ blocks DB Number, ; guaranteed by MMC (maintenance-free) ; Program and data 1 024; Number range: 1 to ; guaranteed by MMC (maintenance-free) ; Program and data 1 024; Number range: 1 to ; guaranteed by MMC (maintenance-free) ; Program and data 1 024; Number range: 1 to ; guaranteed by MMC (maintenance-free) ; Program and data 1 024; Number range: 1 to ; guaranteed by MMC (maintenance-free) ; Program and data Size, 32 Kibyte 64 Kibyte 64 Kibyte 64 Kibyte 64 Kibyte FB Number, 1 024; Number range: 0 to ; Number range: 0 to ; Number range: 0 to ; Number range: 0 to 7999 Size, 32 Kibyte 64 Kibyte 64 Kibyte 64 Kibyte 64 Kibyte FC Number, 1 024; Number range: 0 to ; Number range: 0 to ; Number range: 0 to ; Number range: 0 to 7999 Size, 32 Kibyte 64 Kibyte 64 Kibyte 64 Kibyte 64 Kibyte OB Size, 32 Kibyte 64 Kibyte 64 Kibyte 64 Kibyte 64 Kibyte Nesting depth per priority class additional within an error OB CPU/ processing times for bit operations, min. 0.1 µs 0.06 µs 0.0 µs 0.0 µs for word operations, min µs 0.12 µs 0.09 µs 0.09 µs 0.03 µs for fixed point arithmetic, min. for floating point arithmetic, min. Times/counters and their retentivity S7 counter 0.32 µs 0.16 µs 0.12 µs 0.12 µs 0.04 µs 1.1 µs 0.9 µs 0.4 µs 0.4 µs 0.16 µs Number Retentivity - can be set - lower limit upper limit Counting range - can be set - lower limit upper limit IEC counter present Type SFB SFB SFB SFB SFB 2 048; Number range: 1 to ; Number range: 0 to ; Number range: 0 to 7999 /4

5 Central processing units Standard CPUs Technical specifications (continued) 6ES AE14-6ES AG14-6ES7 31-2AH14-6ES7 31-2EH14-6ES EK14- Product-type designation CPU 312 CPU 314 CPU 31-2 DP CPU 31-2 PN/DP CPU PN/DP S7 times Number Retentivity - can be set - lower limit upper limit preset no retentivity no retentivity no retentivity no retentivity no retentivity Time range - lower limit 10 ms 10 ms 10 ms 10 ms 10 ms - upper limit s s s s s IEC timer present Type SFB SFB SFB SFB SFB Data areas and their retentivity Flag Number, 26 byte 26 byte byte byte byte Retentivity available ; MB 0 to MB 2 ; MB 0 to MB 2 ; MB 0 to MB 2047 ; MB 0 to MB 2047 ; MB 0 to MB 409 Number of clock memories 8; 1 memory byte 8; 1 memory byte 8; 1 memory byte 8; 1 memory byte 8; 1 memory byte Data blocks Number, 1 024; Number range: 1 to ; Number range: 1 to ; Number range: 1 to ; Number range: 1 to Size, 32 Kibyte 64 Kibyte 64 Kibyte 64 Kibyte 64 Kibyte Retentivity adjustable ; via non-retain property on DB ; via non-retain property on DB ; via non-retain property on DB ; via non-retain property on DB Retentivity preset yes yes yes yes yes Local data per priority class, Address area I/O address area 32 Kibyte; Max. 2 KB per block 32 Kibyte; Max. 2 KB per block 32 Kibyte; Max. 2 KB per block 32 Kibyte; Max. 2 KB per block 2 048; Number range: 1 to ; via non-retain property on DB 32 Kibyte; Max. 2 KB per block overall byte byte byte byte byte Outputs byte byte byte byte byte of which, distributed - Inputs byte byte byte - Outputs byte byte byte Process image Inputs byte byte byte byte byte Outputs byte byte byte byte byte Inputs, adjustable byte byte byte byte byte Outputs, adjustable byte byte byte byte byte Inputs, default 128 byte 128 byte 128 byte 128 byte 26 byte Outputs, default 128 byte 128 byte 128 byte 128 byte 26 byte Subprocess images Number of subprocess images, Digital channels Inputs Outputs Inputs, of which central Outputs, of which central /

6 Central processing units Siemens AG 2010 Standard CPUs Technical specifications (continued) 6ES AE14-6ES AG14-6ES7 31-2AH14-6ES7 31-2EH14-6ES EK14- Product-type designation CPU 312 CPU 314 CPU 31-2 DP CPU 31-2 PN/DP CPU PN/DP Analog channels Inputs Outputs Inputs, of which central Outputs, of which central Hardware configuration Central devices, Expansion devices, Racks, Modules per rack, Number of DP masters integrated via CP Number of operable FMs and CPs (recommended) FM CP, point-to-point CP, LAN Time of day Clock Hardware clock (real-time clock) Software clock battery-backed and synchronizable Behavior of the clock following POWER-ON Behavior of the clock following expiry of backup period Buffered: Can be synchronized: The clock continues at the time of day it had when power was switched off The clock continues at the time of day it had when power was switched off The clock continues at the time of day it had when power was switched off The clock continues at the time of day it had when power was switched off The clock continues at the time of day it had when power was switched off Deviation per day, 10 s; Typ.: 2 s 10 s; Typ.: 2 s 10 s; Typ.: 2 s 10 s; Typ.: 2 s 10 s; Typ.: 2 s Runtime meter Number Number/Number range to 3 Range of values 0 to 2^31 hours (when using SFC 101) 0 to 2^31 hours (when using SFC 101) 0 to 2^31 hours (when using SFC 101) 0 to 2^31 hours (when using SFC 101) Granularity 1 hour 1 hour 1 hour 1 hour 1 hour retentive Clock synchronization ; Must be restarted at each restart ; Must be restarted at each restart ; Must be restarted at each restart ; Must be restarted at each restart supported to MPI, master to MPI, slave to DP, master ; on DP slave only time-of-day slave ; on DP slave only time-of-day slave to DP, slave in AS, master in AS, slave 0 to 2^31 hours (when using SFC 101) ; Must be restarted at each restart ; on DP slave only time-of-day slave on Ethernet via NTP ; as client ; as client /6

7 Central processing units Standard CPUs Technical specifications (continued) 6ES AE14-6ES AG14-6ES7 31-2AH14-6ES7 31-2EH14-6ES EK14- Product-type designation CPU 312 CPU 314 CPU 31-2 DP CPU 31-2 PN/DP CPU PN/DP S7 message functions Number of login stations for message functions, Process diagnostic messages simultaneously active Alarm-S blocks, Test commissioning functions Status/control 6; Depending on the connections configured for PG/OP and S7 basic communication 12; Depending on the connections configured for PG/OP and S7 basic communication 16; Depending on the connections configured for PG/OP and S7 basic communication 16; Depending on the connections configured for PG/OP and S7 basic communication Status/control variable Variables Inputs, outputs, memory bits, DB, times, counters Inputs, outputs, memory bits, DB, times, counters Inputs, outputs, memory bits, DB, times, counters Inputs, outputs, memory bits, DB, times, counters Number of variables, of which status variables, of which control variables, Forcing Forcing 32; Depending on the connections configured for PG/OP and S7 basic communication Inputs, outputs, memory bits, DB, times, counters Force, variables Inputs, outputs Inputs, outputs Inputs, outputs Inputs, outputs Inputs, outputs Number of variables, Status block ; Up to 2 simultaneously ; Up to 2 simultaneously ; Up to 2 simultaneously ; Up to 2 simultaneously Single step Number of breakpoints Diagnostic buffer present ; Up to 2 simultaneously Number of entries, can be set - Of which powerfail-proof 100; Only the last 100 entries are retained 100; Only the last 100 entries are retained 100; Only the last 100 entries are retained 100; Only the last 100 entries are retained 100; Only the last 100 entries are retained Maximum number of entries that can be read in RUN - adjustable ; from 10 to 499 ; from 10 to 499 ; from 10 to 499 ; from 10 to 499 ; from 10 to default Service data can be read out Monitoring functions Status LEDs Communication functions PG/OP communication Data record routing Routing ; Max. 4 Global data communication supported Size of GD packets, 22 byte 22 byte 22 byte 22 byte 22 byte S7 basic communication supported /7

8 Central processing units Siemens AG 2010 Standard CPUs Technical specifications (continued) 6ES AE14-6ES AG14-6ES7 31-2AH14-6ES7 31-2EH14-6ES EK14- Product-type designation CPU 312 CPU 314 CPU 31-2 DP CPU 31-2 PN/DP CPU PN/DP S7 communication supported S-compatible communication supported Web server Web server ; via CP and loadable FC ; via CP and loadable FC ; via CP and loadable FC ; via CP and loadable FC ; Read-only function Number of HTTP clients Open IE communication TCP/IP - Number of connections, ISO-on-TCP (RFC1006) ; via integrated PROFINET interface and loadable FBs 8 16 ; via integrated PROFINET interface and loadable FBs ; via CP and loadable FC ; Read-only function ; via integrated PROFINET interface and loadable FBs ; via integrated PROFINET interface and loadable FBs - Number of connections, Data length, byte byte UDP ; via integrated PROFINET interface and loadable FBs ; via integrated PROFINET interface and loadable FBs - Number of connections, Data length, byte byte Number of connections overall usable for PG communication usable for OP communication usable for S7 basic communication usable for S7 communication - reserved for S7 communication - Adjustable for S7 communication, min. - Adjustable for S7 communication, Max. total number of instances usable for routing X1 as MPI: 10; X1 as DP master: 24; X1 as DP slave (active): 14; X2 as PROFINET: 24 PROFINET CBA (at set setpoint communication load) Setpoint for the CPU communication load Number of remote interconnection partners 0 % 0 % X1 as MPI: 10; X1 as DP master: 24; X1 as DP slave (active): 14; X2 as PROFINET: 24 /8

9 Central processing units Standard CPUs Technical specifications (continued) 6ES AE14-6ES AG14-6ES7 31-2AH14-6ES7 31-2EH14-6ES EK14- Product-type designation CPU 312 CPU 314 CPU 31-2 DP CPU 31-2 PN/DP CPU PN/DP PROFINET CBA (at set setpoint communication load) Number of functions, master/slave Total of all Master/Slave connections Data length of all incoming connections master/slave, Data length of all outgoing connections master/slave, Number of device-internal and PROFIBUS interconnections Data length of device-internal und PROFIBUS interconnections, Data length per connection, Remote interconnections with acyclic transmission - Sampling frequency: Sampling time, min. - Number of incoming interconnections - Number of outgoing interconnections - Data length of all incoming interconnections, - Data length of all outgoing interconnections, - Data length per connection, Remote interconnections with cyclic transmission - Transmission frequency: Transmission interval, min. - Number of incoming interconnections - Number of outgoing interconnections - Data length of all incoming interconnections, - Data length of all outgoing interconnections, - Data length per connection, byte byte byte byte byte byte byte byte 00 ms 00 ms byte byte byte byte byte byte 10 ms 10 ms byte byte byte byte 40 byte 40 byte HMI variables via PROFINET (acyclic) - Number of stations that 3; 2x PN OPC/1x imap 3; 2x PN OPC/1x imap can log on for HMI variables (PN OPC/iMap) - HMI variable updating 00 ms 00 ms - Number of HMI variables Data length of all HMI variables, byte byte /9

10 Central processing units Siemens AG 2010 Standard CPUs Technical specifications (continued) 6ES AE14-6ES AG14-6ES7 31-2AH14-6ES7 31-2EH14-6ES EK14- Product-type designation CPU 312 CPU 314 CPU 31-2 DP CPU 31-2 PN/DP CPU PN/DP PROFINET CBA (at set setpoint communication load) PROFIBUS proxy functionality - supported - Number of linked PROFIBUS devices Data length per connection, 1st interface Type of interface Integrated RS 48 interface Integrated RS 48 interface Integrated RS 48 interface 240 byte; Slavedependent Integrated RS 48 interface Physics RS 48 RS 48 RS 48 RS 48 RS 48 Isolated Power supply to interface (1 to 30 V DC), Functionality 200 ma 200 ma 200 ma 200 ma 200 ma MPI DP master DP slave Point-to-point connection MPI Number of connections byte; Slavedependent Integrated RS 48 interface Services - PG/OP communication - Routing - Global data communication - S7 basic communication - S7 communication - S7 communication, as client ; but via CP and loadable FB ; but via CP and loadable FB - S7 communication, as server Transmission speeds, 187. kbit/s 187. kbit/s 187. kbit/s 12 Mbit/s 12 Mbit/s DP master Services - PG/OP communication - Routing - Global data communication - S7 basic communication ; I blocks only ; I blocks only - S7 communication - S7 communication, as client - S7 communication, as server - Equidistance mode support - Isochronous mode ; OB 61 ; OB 61 - SYNC/FREEZE - Activation/deactivation of DP slaves - Number of DP slaves that 8 8 can be simultaneously activated/deactivated, - DPV1 /10

11 Central processing units Standard CPUs Technical specifications (continued) 6ES AE14-6ES AG14-6ES7 31-2AH14-6ES7 31-2EH14-6ES EK14- Product-type designation CPU 312 CPU 314 CPU 31-2 DP CPU 31-2 PN/DP CPU PN/DP DP master Transmission speeds, 12 Mbit/s 12 Mbit/s Number of DP slaves, Address area - Inputs, 2 Kibyte 8 Kibyte - Outputs, 2 Kibyte 8 Kibyte User data per DP slave - Inputs, 244 byte 244 byte - Outputs, 244 byte 244 byte DP slave Services - PG/OP communication - Routing ; Only with active interface ; Only with active interface - Global data communication - S7 basic communication - S7 communication - S7 communication, as client - S7 communication, as server ; Connection configured on one side only ; Connection configured on one side only - Direct data exchange (slave-to-slave communication) - DPV1 Transmission rate, 12 Mbit/s 12 Mbit/s Transfer memory - Inputs 244 byte 244 byte - Outputs 244 byte 244 byte Address area, User data per address area, 2nd interface Type of interface integrated RS 48 interface 32 byte 32 byte PROFINET PROFINET Physics RS 48 Ethernet RJ4 Ethernet RJ4 Isolated Integrated switch Number of ports 2 2 Power supply to interface (1 to 30 V DC), automatic detection of transmission speed 200 ma ; 10/100 Mbit/s Autonegotiation Autocrossing Functionality MPI DP master DP slave PROFINET IO Controller PROFINET CBA ; 10/100 Mbit/s Web server ; ; only read function only read function - Number of HTTP clients Point-to-point connection /11

12 Central processing units Siemens AG 2010 Standard CPUs Technical specifications (continued) 6ES AE14-6ES AG14-6ES7 31-2AH14-6ES7 31-2EH14-6ES EK14- Product-type designation CPU 312 CPU 314 CPU 31-2 DP CPU 31-2 PN/DP CPU PN/DP DP master Number of connections, Services - PG/OP communication - Routing - Global data communication - S7 basic communication ; I blocks only - S7 communication - S7 communication, as client - S7 communication, as server - Equidistance mode support - Isochronous mode ; OB 61 - SYNC/FREEZE - Activation/deactivation of DP slaves - Number of DP slaves that 8 can be simultaneously activated/deactivated, - DPV1 Transmission speeds, Number of DP slaves, Mbit/s 124; Per station Address area - Inputs, byte - Outputs, byte User data per DP slave - Inputs, 244 byte - Outputs, 244 byte DP slave Number of connections 16 Services - PG/OP communication - Routing ; Only with active interface - Global data communication - S7 basic communication - S7 communication, as client - S7 communication, as server - Direct data exchange (slave-to-slave communication) - DPV1 GSD file Transmission rate, automatic baud rate search The current GSD file can be obtained from: com/profibus-gsd 12 Mbit/s Transfer memory - Inputs 244 byte - Outputs 244 byte ; only with passive interface /12

13 Central processing units Standard CPUs Technical specifications (continued) 6ES AE14-6ES AG14-6ES7 31-2AH14-6ES7 31-2EH14-6ES EK14- Product-type designation CPU 312 CPU 314 CPU 31-2 DP CPU 31-2 PN/DP CPU PN/DP DP slave Address area, 32 User data per address area, PROFINET IO Controller 32 byte Services - PG/OP communication - Routing - S7 communication ; with loadable FBs, configurable connections: 14, number of instances: 32 ; with loadable FBs, configurable connections: 16, number of instances: 32 - Isochronous mode - Open IE communication ; via TCP/IP, ISO ; via TCP/IP, ISO on TCP and UDP on TCP and UDP Transmission rate, 100 Mbit/s 100 Mbit/s Total number of connectable IO Devices, Max. number of connectable IO devices for RT - of which in line, Number of IO Devices with IRT and the option "high flexibility" - of which in line, IRT, supported Prioritized startup supported - Number of IO Devices, Activation/deactivation of IO Devices - Number of IO Devices that can be simultaneously activated/deactivated, IO Devices changing during operation (partner ports), supported - Max. number of IO devices per tool Device replacement without swap medium Updating time µs ms (with send cycle of 20 µs); 00 µs - 26 ms (with send cycle of 00 µs); 1 ms - 12 ms (with send cycle 1 ms); minimum value of the send cycle is also dependent on the set communication share for PROFINET IO, on the number of IO Devices Address area - Inputs, 2 Kibyte 8 Kibyte - Outputs, 2 Kibyte 8 Kibyte 20 µs ms (with send cycle of 20 µs); 00 µs - 26 ms (with send cycle of 00 µs); 1 ms - 12 ms (with send cycle 1 ms); minimum value of the send cycle is also dependent on the set communication share for PROFINET IO, on the number of IO Devices /13

14 Central processing units Siemens AG 2010 Standard CPUs Technical specifications (continued) 6ES AE14-6ES AG14-6ES7 31-2AH14-6ES7 31-2EH14-6ES EK14- Product-type designation CPU 312 CPU 314 CPU 31-2 DP CPU 31-2 PN/DP CPU PN/DP PROFINET IO Controller User data per address area, - User data consistency, PROFINET CBA 24 byte 24 byte acyclic transmission cyclic transmission Open IE communication Open IE communication, supported Number of connections, Local port numbers used at the system end CPU/ programming Programming language STEP 7 ; V.2 SP1 or higher with HW update ; V.2 SP1 or higher with HW update ; V.2 SP1 or higher with HW update 8 8 0, 20, 21, 2, 80, 102, 13, 161, 8 080, , , , 6 32, 6 33, 6 34, 6 3 ; V.4 SP4 or higher with HW update LAD FBD STL SCL CFC GRAPH HiGraph 0, 20, 21, 2, 80, 102, 13, 161, 8 080, , , , 6 32, 6 33, 6 34, 6 3 ; V.4 SP4 or higher with HW update Command set See instruction list See instruction list See instruction list See instruction list See instruction list Nesting levels User program protection/password protection System functions (SFC) see instruction list see instruction list see instruction list see instruction list see instruction list System function blocks (SFB) Environmental requirements Operating temperature see instruction list see instruction list see instruction list see instruction list see instruction list Min. 0 C 0 C 60 C 60 C Dimensions and weight Dimensions Width 40 mm 40 mm 40 mm 40 mm 40 mm Height 12 mm 12 mm 12 mm 12 mm 12 mm Depth 130 mm 130 mm 130 mm 130 mm 130 mm Weight Weight, approx. 270 g 280 g 290 g 340 g 340 g /14

15 Central processing units Standard CPUs Ordering data Order. Order. CPU 312 C 6ES AE14- Main memory 32 KB, power supply 24 V DC, MPI; MMC required CPU 314 C 6ES AG14- Main memory 128 KB, power supply 24 V DC, MPI; MMC required CPU 31-2 DP 26 KB main memory, 24 V DC power supply, MPI, PROFIBUS DP master/slave interface, MMC required CPU 31-2 PN/DP 384 KB main memory, 24 V DC power supply, combined MPI/PROFIBUS DP master/slave interface, Ethernet/PROFINET interface with 2-port switch; MMC required CPU PN/DP Main memory 1 MB, power supply 24 V DC, combined MPI/PROFIBUS DP master/slave interface, Ethernet/PROFINET interface with 2-port switch; MMC required Accessories SIMATIC Micro Memory Card 6ES7 31-2AH14-6ES7 31-2EH14-6ES EK14-64 KB 6ES7 93-8LF20-0AA0 128 KB 6ES7 93-8LG11-0AA0 12 KB 6ES7 93-8LJ20-0AA0 2 MB 6ES7 93-8LL20-0AA0 4 MB 6ES7 93-8LM20-0AA0 8 MB 6ES7 93-8LP20-0AA0 MPI cable for connecting SIMATIC S7 and the PG through MPI; m in length Slot number plates S7-300 manual Design, CPU data, module data, instruction list German English French Spanish Italian 6ES BF00-0AA0 6ES AA00-0AA0 6ES FA10-8AA0 6ES FA10-8BA0 6ES FA10-8CA0 6ES FA10-8DA0 6ES FA10-8EA0 SIMATIC Manual Collection A 6ES XC01-8YE0 Electronic manuals on DVD, multilingual: S7-200, S7-300, C7, S7-400, SIMATIC DP (Distributed I/O), SIMATIC PC, SIMATIC PG (Programming device), STEP 7, Engineering Tools, Runtime Software, SIMATIC PCS 7, SIMATIC HMI (Human Machine Interface), SIMATIC NET (Industrial Communication), SIMATIC Machine Vision, SIMATIC Sensors A: Subject to export regulations: AL: N and ECCN: EAR99S C: Subject to export regulations: AL: N and ECCN: EAR99H SIMATIC Manual Collection update service for 1 year Current "Manual Collection" DVD and the three subsequent updates Power supply connector 10 units, spare part Manual "Communication for /-400" German English French Spanish Italian SIMATIC S7 demo case with mounting components for mounting S7-200 and S7-300 PC adapter USB for connecting a PC to SIMATIC S7-200/300/400 via USB; with USB cable ( m) PROFIBUS bus components PROFIBUS DP bus connector RS 48 with 90 cable outlet, transmission rate 12 Mbit/s D: Subject to export regulations: AL: N and ECCN: D992 D 6ES XC01-8YE2 6ES AA00-0AA0 6ES EA00-8AA0 6ES EA00-8BA0 6ES EA00-8CA0 6ES EA00-8DA0 6ES EA00-8EA0 6ES AA00-0XA0 6ES CB20-0XA0 - without PG interface 6ES BA12-0XA0 - with PG interface 6ES BB12-0XA0 with 90 cable outlet for Fast- Connect connection system, transmission rate 12 Mbit/s - without PG interface, 1 unit 6ES BA2-0XA0 - without PG interface, 100 units 6ES BA2-0XB0 - with PG interface, 1 unit 6ES BB2-0XA0 - with PG interface, 100 units 6ES BB2-0XB0 with axial cable outlet for SIMATIC OP, for connecting to PPI, MPI, PROFIBUS PROFIBUS Fast Connect bus cable Standard type with special design for quick mounting, 2-core, shielded, sold by the meter, delivery unit 1000 m, minimum ordering quantity 20 m RS 48 repeater for PROFIBUS Data transfer rate up to 12 Mbit/s; 24 V DC; IP20 housing 6GK1 00-0EA02 6XV EH10 6ES AA01-0XA0 /1

16 Central processing units Siemens AG 2010 Standard CPUs Ordering data Order. Order. PROFINET bus components IE FC TP standard cable GP 2x2 4-core, shielded TP installation cable for connection to IE FC Outlet RJ4/ IE FC RJ4 Plug; PROFINET-compatible; with UL approval; Sold by the meter 6XV AH10 FO Standard Cable GP (0/12) 6XV A Standard cable, splittable, UL approval, sold by the meter SCALANCE X204-2 Industrial Ethernet Switch Industrial Ethernet Switches with integral SNMP access, web diagnostics, copper cable diagnostics and PROFINET diagnostics for configuring line, star and ring topologies; four 10/100 Mbit/s RJ4 ports and two FO ports Compact Switch Module CSM 377 Unmanaged switch for connecting a, ET 200M and up to three other participants to Industrial Ethernet with 10/100 Mbit/s; 4 x RJ4 ports; external 24 V DC power supply, LED diagnostics, S7-300 module incl. electronic manual on CD-ROM 6GK 204-2BB10-2AA3 6GK AA00-0AA0 IE FC RJ4 plugs RJ4 plug connector for Industrial Ethernet with a rugged metal enclosure and integrated insulation displacement contacts for connecting Industrial Ethernet FC installation cables IE FC RJ4 plug cable outlet 1 unit 6GK BB30-0AA0 10 units 6GK BB30-0 units 6GK BB30-0AE0 IE FC RJ4 plug cable outlet 1 unit 6GK BB10-2AA0 10 units 6GK BB10-2AB0 0 units 6GK BB10-2AE0 PROFIBUS/PROFINET bus components for establishing MPI/PROFIBUS/PROFINET communication see catalogs IK PI, CA 01 /16

17 Central processing units Fail-safe CPUs Overview CPU 31F-2 DP Overview CPU 31F-2 PN/DP Based on the SIMATIC CPU 31-2 DP For setting up a fail-safe automation system in plants with increased safety requirements Complies with safety requirements up to SIL 3 according to IEC 6108 and up to Cat. 4 according to EN 94-1 Distributed fail-safe I/O modules can be connected through the integral PROFIBUS DP interface (PROFIsafe) Fail-safe I/O modules of the ET 200M range can also be centrally connected Central and distributed use of standard modules for non safety-oriented applications SIMATIC Micro Memory Card required for operation of CPU. Based on CPU 31-2 PN/DP The CPU with medium-sized program memory and quantity structures for setting up a fail-safe automation system in plants with increased safety requirements Complies with safety requirements up to SIL 3 according to IEC 6108, PL e according to ISO 13849, and up to Cat. 4 according to EN 94-1 Fail-safe I/O modules in distributed stations can be connected through the integrated PROFINET interface (PROFIsafe) and/or through the integrated PROFIBUS DP interface (PROFIsafe); Fail-safe I/O modules of the ET 200M range can also be centrally connected Central and distributed use of standard modules for non safety-relevant applications Component Based Automation (CBA) on PROFINET PROFINET IO Controller for operating distributed I/O on PROFINET PROFINET interface with 2-port switch PROFINET proxy for intelligent devices on PROFIBUS DP in Component Based Automation (CBA) SIMATIC Micro Memory Card required for operation of CPU. /17

18 Central processing units Siemens AG 2010 Fail-safe CPUs Overview CPU 317F-2 PN/DP Based on CPU PN/DP The fail-safe CPU with a large program memory and quantity framework for demanding applications; for setting up a fail-safe automation system in plants with increased safety requirements. Complies with safety requirements up to SIL 3 according to IEC 6108, PL e according to ISO , and up to Cat. 4 according to EN 94-1 Fail-safe I/O modules in distributed stations can be connected through the integrated PROFINET interface (PROFIsafe) and/or through the integrated PROFIBUS DP interface (PROFIsafe) Fail-safe I/O modules of the ET 200M range can also be centrally connected Central and distributed use of standard modules for non safety-relevant applications Component Based Automation (CBA) on PROFINET PROFINET IO Controller for operating distributed I/O on PROFINET PROFINET interface with 2-port switch PROFINET proxy for intelligent devices on PROFIBUS DP in Component Based Automation (CBA) SIMATIC Micro Memory Card required for operation of CPU. Technical specifications 6ES7 31-6FF04-6ES7 31-2FJ14-6ES FK14- Product-type designation CPU 31F-2 DP CPU 31F-2 PN/DP CPU 317F-2 PN/DP Product version associated programming package STEP 7 > V.4 + SP or STEP 7 as of V.2 + SP1 with HSP 177, S7 Distributed Safety as of V.4 Supply voltages Rated value 24 V DC permissible range, lower limit (DC) 20.4 V 20.4 V 20.4 V permissible range, upper limit (DC) 28.8 V 28.8 V 28.8 V external protection for supply cables (recommendation) Current consumption Min. 2 A Min. 2 A Min. 2 A Current consumption (rated value) 80 ma 70 ma 70 ma Current consumption (in no-load operation), typ. 10 ma 10 ma 10 ma Inrush current, typ. 3. A 4 A 4 A I²t 1 A² s 1 A² s 1 A² s from supply voltage L+, Power loss Power loss, typ. Memory Work memory 900 ma 4. W integrated 384 Kibyte 12 Kibyte 1. Mbyte expandable Size of retentive memory for retentive data blocks Load memory 128 Kibyte 128 Kibyte 26 Kibyte pluggable (MMC) pluggable (MMC), 8 Mbyte 8 Mbyte 8 Mbyte /18

19 Central processing units Fail-safe CPUs Technical specifications (continued) 6ES7 31-6FF04-6ES7 31-2FJ14-6ES FK14- Product-type designation CPU 31F-2 DP CPU 31F-2 PN/DP CPU 317F-2 PN/DP Backup present ; guaranteed by MMC (maintenance-free) ; guaranteed by MMC (maintenance-free) ; guaranteed by MMC (maintenance-free) without battery ; Program and data ; Program and data ; Program and data CPU/ blocks DB Number, 1 024; Number range: 1 to ; Number range: 1 to Size, 64 Kibyte 64 Kibyte 64 Kibyte FB 2 048; Number range: 1 to Number, 1 024; Number range: 0 to ; Number range: 0 to ; Number range: 0 to 7999 Size, 64 Kibyte 64 Kibyte 64 Kibyte FC Number, 1 024; Number range: 0 to ; Number range: 0 to ; Number range: 0 to 7999 Size, 64 Kibyte 64 Kibyte 64 Kibyte OB Size, 64 Kibyte 64 Kibyte 64 Kibyte Nesting depth per priority class additional within an error OB CPU/ processing times for bit operations, min. 0.0 µs 0.0 µs for word operations, min µs 0.09 µs 0.03 µs for fixed point arithmetic, min µs 0.12 µs 0.04 µs for floating point arithmetic, min. 0.4 µs 0.4 µs 0.16 µs Times/counters and their retentivity S7 counter Number Retentivity - can be set - lower limit upper limit Counting range - can be set - lower limit upper limit IEC counter present Type SFB SFB SFB S7 times Number Retentivity - can be set - lower limit upper limit preset no retentivity no retentivity no retentivity Time range - lower limit 10 ms 10 ms 10 ms - upper limit s s s /19

20 Central processing units Siemens AG 2010 Fail-safe CPUs Technical specifications (continued) 6ES7 31-6FF04-6ES7 31-2FJ14-6ES FK14- Product-type designation CPU 31F-2 DP CPU 31F-2 PN/DP CPU 317F-2 PN/DP IEC timer present Type SFB SFB SFB Data areas and their retentivity Flag Number, byte byte byte Retentivity available ; MB 0 to MB 2047 ; MB 0 to MB 2047 ; MB 0 to MB 409 Number of clock memories 8; 1 memory byte 8; 1 memory byte 8; 1 memory byte Data blocks Number, 1 024; Number range: 1 to ; Number range: 1 to Size, 64 Kibyte 64 Kibyte 64 Kibyte Retentivity adjustable ; via non-retain property on DB ; via non-retain property on DB Retentivity preset yes yes yes Local data 2 048; Number range: 1 to ; via non-retain property on DB per priority class, 32 Kibyte; Max. 2 KB per block 32 Kibyte; Max. 2 KB per block 32 Kibyte; Max. 2 KB per block Address area I/O address area overall byte byte byte Outputs byte byte byte of which, distributed - Inputs byte byte byte - Outputs byte byte byte Process image Inputs byte byte byte Outputs byte byte byte Inputs, adjustable byte byte byte Outputs, adjustable byte byte byte Inputs, default 384 byte 384 byte byte Outputs, default 384 byte 384 byte byte Subprocess images Number of subprocess images, Digital channels Inputs Outputs Inputs, of which central Outputs, of which central Analog channels Inputs Outputs Inputs, of which central Outputs, of which central Hardware configuration Central devices, Expansion devices, Racks, Modules per rack, /20

21 Central processing units Fail-safe CPUs Technical specifications (continued) 6ES7 31-6FF04-6ES7 31-2FJ14-6ES FK14- Product-type designation CPU 31F-2 DP CPU 31F-2 PN/DP CPU 317F-2 PN/DP Number of DP masters integrated via CP Number of operable FMs and CPs (recommended) FM CP, point-to-point CP, LAN Time of day Clock Hardware clock (real-time clock) battery-backed and synchronizable Behavior of the clock following expiry of backup period The clock continues at the time of day it had when power was switched off The clock continues at the time of day it had when power was switched off Deviation per day, 10 s; Typ.: 2 s 10 s; Typ.: 2 s 10 s; Typ.: 2 s Runtime meter Number Number/Number range to 3 Range of values 0 to 2^31 hours (when using SFC 101) 0 to 2^31 hours (when using SFC 101) Granularity 1 hour 1 hour 1 hour retentive Clock synchronization ; Must be restarted at each restart ; Must be restarted at each restart supported to MPI, master to MPI, slave to DP, master ; on DP slave only time-ofday slave ; on DP slave only time-ofday slave to DP, slave in AS, master in AS, slave The clock continues at the time of day it had when power was switched off 0 to 2^31 hours (when using SFC 101) on Ethernet via NTP ; as client ; as client S7 message functions Number of login stations for message functions, 16; Depending on the connections configured for PG/OP and S7 basic communication 16; Depending on the connections configured for PG/OP and S7 basic communication Process diagnostic messages simultaneously active Alarm-S blocks, Test commissioning functions Status/control Status/control variable Variables Inputs, outputs, memory bits, DB, times, counters Inputs, outputs, memory bits, DB, times, counters Number of variables, of which status variables, of which control variables, Forcing Forcing ; Must be restarted at each restart ; on DP slave only time-ofday slave 32; Depending on the connections configured for PG/OP and S7 basic communication Inputs, outputs, memory bits, DB, times, counters Force, variables Inputs, outputs Inputs, outputs Inputs, outputs Number of variables, /21

22 Central processing units Siemens AG 2010 Fail-safe CPUs Technical specifications (continued) 6ES7 31-6FF04-6ES7 31-2FJ14-6ES FK14- Product-type designation CPU 31F-2 DP CPU 31F-2 PN/DP CPU 317F-2 PN/DP Status block ; Up to 2 simultaneously ; Up to 2 simultaneously ; Up to 2 simultaneously Single step Number of breakpoints Diagnostic buffer present Number of entries, can be set - Of which powerfail-proof 100; Only the last 100 entries are 100; Only the last 100 entries are 100; Only the last 100 entries are retained retained retained Maximum number of entries that can be read in RUN - adjustable ; from 10 to 499 ; from 10 to 499 ; from 10 to default Service data can be read out Monitoring functions Status LEDs Communication functions PG/OP communication Data record routing Routing ; Max. 4 Global data communication supported Size of GD packets, 22 byte 22 byte 22 byte S7 basic communication supported S7 communication supported S-compatible communication supported ; via CP and loadable FC ; via CP and loadable FC ; via CP and loadable FC Web server Web server ; Read-only function ; Read-only function Number of HTTP clients Open IE communication TCP/IP ; via integrated PROFINET ; via integrated PROFINET interface and loadable FBs interface and loadable FBs - Number of connections, 8 16 ISO-on-TCP (RFC1006) ; via integrated PROFINET interface and loadable FBs ; via integrated PROFINET interface and loadable FBs - Number of connections, Data length, byte byte UDP ; via integrated PROFINET interface and loadable FBs ; via integrated PROFINET interface and loadable FBs - Number of connections, Data length, byte byte Number of connections overall usable for PG communication usable for OP communication usable for S7 basic communication usable for S7 communication reserved for S7 communication Adjustable for S7 communication, min Adjustable for S7 communication, /22

23 Central processing units Fail-safe CPUs Technical specifications (continued) 6ES7 31-6FF04-6ES7 31-2FJ14-6ES FK14- Product-type designation CPU 31F-2 DP CPU 31F-2 PN/DP CPU 317F-2 PN/DP Number of connections Max. total number of instances usable for routing X1 as MPI: 10; X1 as DP master: 24; X1 as DP slave (active): 14; X2 as PROFINET: 24 PROFINET CBA (at set setpoint communication load) Setpoint for the CPU communication load 0 % 0 % Number of remote interconnection partners Number of functions, master/slave Total of all Master/Slave connections Data length of all incoming connections master/slave, Data length of all outgoing connections master/slave, Number of device-internal and PROFIBUS interconnections Data length of device-internal and PROFIBUS interconnections, byte byte byte byte byte byte Data length per connection, byte byte Remote interconnections with acyclic transmission - Sampling frequency: Sampling time, min. 00 ms 00 ms - Number of incoming interconnections Number of outgoing interconnections Data length of all incoming interconnections, byte byte - Data length of all outgoing interconnections, byte byte - Data length per connection, byte byte Remote interconnections with cyclic transmission - Transmission frequency: 10 ms 10 ms Transmission interval, min. - Number of incoming interconnections Number of outgoing interconnections Data length of all incoming interconnections, byte byte - Data length of all outgoing interconnections, byte byte - Data length per connection, 40 byte 40 byte X1 as MPI: 10; X1 as DP master: 24; X1 as DP slave (active): 14; X2 as PROFINET: 24 HMI variables via PROFINET (acyclic) - Number of stations that can log on for HMI 3; 2x PN OPC/1x imap 3; 2x PN OPC/1x imap variables (PN OPC/iMap) - HMI variable updating 00 ms 00 ms - Number of HMI variables Data length of all HMI variables, byte byte PROFIBUS proxy functionality - supported - Number of linked PROFIBUS devices Data length per connection, 240 byte; Slave-dependent 240 byte; Slave-dependent 1st interface Type of interface Integrated RS 48 interface Integrated RS 48 interface Integrated RS 48 interface Physics RS 48 RS 48 RS 48 Isolated Power supply to interface (1 to 30 V DC), 200 ma 200 ma 200 ma /23

24 Central processing units Siemens AG 2010 Fail-safe CPUs Technical specifications (continued) 6ES7 31-6FF04-6ES7 31-2FJ14-6ES FK14- Product-type designation CPU 31F-2 DP CPU 31F-2 PN/DP CPU 317F-2 PN/DP Functionality MPI DP master DP slave Point-to-point connection MPI Number of connections Services - PG/OP communication - Routing - Global data communication - S7 basic communication - S7 communication - S7 communication, as client ; but via CP and loadable FB ; but via CP and loadable FB - S7 communication, as server Transmission speeds, 187. kbit/s 12 Mbit/s 12 Mbit/s DP master Services - PG/OP communication - Routing - Global data communication - S7 basic communication ; I blocks only ; I blocks only - S7 communication - S7 communication, as client - S7 communication, as server - Equidistance mode support - Isochronous mode ; OB 61 ; OB 61 - SYNC/FREEZE - Activation/deactivation of DP slaves - Number of DP slaves that can be simultaneously 8 8 activated/deactivated, - DPV1 Transmission speeds, 12 Mbit/s 12 Mbit/s Number of DP slaves, Address area - Inputs, 2 Kibyte 8 Kibyte - Outputs, 2 Kibyte 8 Kibyte User data per DP slave - Inputs, 244 byte 244 byte - Outputs, 244 byte 244 byte DP slave Services - PG/OP communication - Routing ; Only with active interface ; Only with active interface - Global data communication - S7 basic communication - S7 communication - S7 communication, as client - S7 communication, as server ; Connection configured on one side only ; Connection configured on one side only - Direct data exchange (slave-to-slave communication) - DPV1 Transmission rate, 12 Mbit/s 12 Mbit/s Transfer memory - Inputs 244 byte 244 byte - Outputs 244 byte 244 byte Address area, User data per address area, 32 byte 32 byte /24

25 Central processing units Fail-safe CPUs Technical specifications (continued) 6ES7 31-6FF04-6ES7 31-2FJ14-6ES FK14- Product-type designation CPU 31F-2 DP CPU 31F-2 PN/DP CPU 317F-2 PN/DP 2nd interface Type of interface integrated RS 48 interface PROFINET PROFINET Physics RS 48 Ethernet RJ4 Ethernet RJ4 Isolated Integrated switch Number of ports 2 2 Power supply to interface (1 to 30 V DC), 200 ma automatic detection of transmission speed ; 10/100 Mbit/s ; 10/100 Mbit/s Autonegotiation Autocrossing Functionality MPI DP master DP slave PROFINET IO Controller PROFINET CBA Web server ; only read function ; only read function - Number of HTTP clients Point-to-point connection DP master Number of connections, 16 Services - PG/OP communication - Routing - Global data communication - S7 basic communication ; I blocks only - S7 communication - S7 communication, as client - S7 communication, as server - Equidistance mode support - Isochronous mode ; OB 61 - SYNC/FREEZE - Activation/deactivation of DP slaves - Number of DP slaves that can be simultaneously 8 activated/deactivated, - DPV1 Transmission speeds, Number of DP slaves, 12 Mbit/s 124; Per station Address area - Inputs, byte - Outputs, byte User data per DP slave - Inputs, 244 byte - Outputs, 244 byte DP slave Number of connections 16 Services - PG/OP communication - Routing ; Only with active interface - Global data communication - S7 basic communication /2

26 Central processing units Siemens AG 2010 Fail-safe CPUs Technical specifications (continued) 6ES7 31-6FF04-6ES7 31-2FJ14-6ES FK14- Product-type designation CPU 31F-2 DP CPU 31F-2 PN/DP CPU 317F-2 PN/DP DP slave Services - S7 communication, as client - S7 communication, as server - Direct data exchange (slave-to-slave communication) - DPV1 GSD file Transmission rate, automatic baud rate search The current GSD file can be obtained from: siemens.com/profibus-gsd 12 Mbit/s Transfer memory - Inputs 244 byte - Outputs 244 byte Address area, 32 User data per address area, PROFINET IO Controller ; only with passive interface 32 byte Services - PG/OP communication - Routing - S7 communication ; with loadable FBs, configurable connections: 14, number of instances: 32 ; with loadable FBs, configurable connections: 16, number of instances: 32 - Isochronous mode - Open IE communication ; via TCP/IP, ISO on TCP and ; via TCP/IP, ISO on TCP and UDP UDP Transmission rate, 100 Mbit/s 100 Mbit/s Total number of connectable IO Devices, Max. number of connectable IO devices for RT - of which in line, Number of IO Devices with IRT and the option "high flexibility" - of which in line, IRT, supported Prioritized startup supported - Number of IO Devices, Activation/deactivation of IO Devices - Number of IO Devices that can be simultaneously 8 8 activated/deactivated, IO Devices changing during operation (partner ports), supported - Max. number of IO devices per tool 8 8 Device replacement without swap medium Updating time 20 µs ms (with send cycle of 20 µs); 00 µs - 26 ms (with send cycle of 00 µs); 1 ms - 12 ms (with send cycle 1 ms); minimum value of the send cycle is also dependent on the set communication share for PROFINET IO, on the number of IO Devices 20 µs ms (with send cycle of 20 µs); 00 µs - 26 ms (with send cycle of 00 µs); 1 ms - 12 ms (with send cycle 1 ms); minimum value of the send cycle is also dependent on the set communication share for PROFINET IO, on the number of IO Devices /26

27 Central processing units Fail-safe CPUs Technical specifications (continued) 6ES7 31-6FF04-6ES7 31-2FJ14-6ES FK14- Product-type designation CPU 31F-2 DP CPU 31F-2 PN/DP CPU 317F-2 PN/DP PROFINET IO Controller Address area - Inputs, 2 Kibyte 8 Kibyte - Outputs, 2 Kibyte 8 Kibyte User data per address area, - User data consistency, 24 byte 24 byte PROFINET CBA acyclic transmission cyclic transmission Open IE communication Open IE communication, supported Number of connections, 8 8 Local port numbers used at the system end 0, 20, 21, 2, 80, 102, 13, 161, 8 080, , , , 6 32, 6 33, 6 34, 6 3 CPU/ programming Programming language STEP 7 ; V.2 SP1 or higher with HW update ; V.4 SP4 or higher with HW update LAD FBD STL SCL CFC GRAPH HiGraph 0, 20, 21, 2, 80, 102, 13, 161, 8 080, , , , 6 32, 6 33, 6 34, 6 3 ; V.4 SP4 or higher with HW update Command set See instruction list See instruction list See instruction list Nesting levels User program protection/ password protection System functions (SFC) see instruction list see instruction list see instruction list System function blocks (SFB) see instruction list see instruction list see instruction list Environmental requirements Operating temperature Min. 0 C 0 C 60 C 60 C Dimensions and weight Dimensions Width 40 mm 40 mm 40 mm Height 12 mm 12 mm 12 mm Depth 130 mm 130 mm 130 mm Weight Weight, approx. 290 g /27

CPU 319-3 PN/DP. Function

CPU 319-3 PN/DP. Function CPU 319-3 PN/DP Function Password protection; a password concept protects the user program from unauthorized access. Block encryption; the functions (FCs) and function blocks (FBs) can be stored in the

More information

SIMATIC S7-300, CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 128 KBYTE WORKING MEMORY 2

SIMATIC S7-300, CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 128 KBYTE WORKING MEMORY 2 6ES7315-2AG10-0AB0 Page 1 Product data sheet 6ES7315-2AG10-0AB0 SIMATIC S7-300, CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 128 KBYTE WORKING MEMORY 2. INTERFACE DP-MASTER/SLAVE

More information

CPUs - CPU 315-2 PN/DP

CPUs - CPU 315-2 PN/DP Overview The CPU with a medium program memory and quantity framework High processing performance in binary and floating-point arithmetic Used as a central controller on production lines with central and

More information

6ES7 313-6BE01-0AB0 6ES7 313-5BE01-0AB0

6ES7 313-6BE01-0AB0 6ES7 313-5BE01-0AB0 4 SIMATIC S7-300 Central processing units CPU 312C to CPU 317F-2 DP CPU 317F-2 DP The failsafe CPU with a large program memory and quantity framework for demanding applications For configuration of a failsaf

More information

6ES7314-6CG03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

6ES7314-6CG03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A 6ES7314-6CG03-0AB0 Page 1 Product data sheet 6ES7314-6CG03-0AB0 SIMATIC S7-300, CPU 314C-2DP COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO, 1 PT100, 4 FAST COUNTERS (60 KHZ), INTEGRATED DP INTERFACE, INTEGRATED

More information

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A 6ES7313-5BF03-0AB0 Page 1 Product data sheet 6ES7313-5BF03-0AB0 SIMATIC S7-300, CPU 313C, COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO 1 PT100, 3 FAST COUNTERS (30 KHZ), INTEGRATED 24V DC POWER SUPPLY,

More information

Data sheet SLIO CPU 015 (015-CEFPR00)

Data sheet SLIO CPU 015 (015-CEFPR00) Data sheet SLIO CPU 015 (015-CEFPR00) Technical data Order no. 015-CEFPR00 SLIO CPU 015 Module ID - General information Note - Features SPEED7 technology 256 kb work memory Memory extension (max. 512 kb)

More information

Siemens AG 2013. 6/56 Digital modules 6/56 SM 421 digital input module 6/59 SM 422 digital output module

Siemens AG 2013. 6/56 Digital modules 6/56 SM 421 digital input module 6/59 SM 422 digital output module Siemens AG 2013 SIMATIC S7-400 /2 Introduction /4 Central processing units /4 Standard CPUs /4 CPU 412 /8 CPU 414 /13 CPU 41 /18 CPU 417 /21 SIPLUS Standard CPUs /21 SIPLUS CPU 412 /22 SIPLUS CPU 414 /23

More information

http://support.automation.siemens.com/ww/view/en/4067870&td=1

http://support.automation.siemens.com/ww/view/en/4067870&td=1 6ES7316-2AG00-0AB0 SIMATIC S7-300, CPU 316 Technical / CAx data nmlkji Technical Data nmlkj CAx data As of 2010-01-24 Power supply Input voltage Rated value (DC) permissible range, lower limit (DC) permissible

More information

S7-1500/S7-1500F Technical Data

S7-1500/S7-1500F Technical Data Standard CPUs CPU 1511-1 PN CPU 1513-1 PN CPU 1515-2 PN Type Standard CPU Standard CPU Standard CPU Dimensions 35 x 147 x 129 mm 35 x 147 x 129 mm 70 x 147 x 129 mm Spare part availability after 10 years

More information

SIMATIC S7-300 4/2 Introduction Function modules (continued) 4/4 Central processing units 4/38 SIPLUS central processing units 4/40 Digital modules

SIMATIC S7-300 4/2 Introduction Function modules (continued) 4/4 Central processing units 4/38 SIPLUS central processing units 4/40 Digital modules /2 Introduction /2 S7-300/S7-300F / Central processing units / CPU 312C to CPU 317F-2 DP /38 SIPLUS central processing units /38 SIPLUS CPU 312C, CPU 313C, CPU 31, CPU 315-2 DP /0 Digital modules /0 SM

More information

The CP 342-5 provides access to different communication services of the PROFIBUS bus system:

The CP 342-5 provides access to different communication services of the PROFIBUS bus system: SIPLUS CP 342-5 Function The CP 342-5 provides access to different communication services of the PROFIBUS bus system: PROFIBUS DP (according to IEC 61158/61784, master or slave) PG/OP communication S7

More information

CP 342-5. Page 1342 Mar 2008 Siemens ITS

CP 342-5. Page 1342 Mar 2008 Siemens ITS CP 342-5 Function The CP 342-5 provides access to different communication services of the PROFIBUS bus system: PROFIBUS DP (according to IEC 61158/61784, master or slave) PG/OP communication S7 communication

More information

The CP 342-5 FO provides access to different communication services of the PROFIBUS bus system:

The CP 342-5 FO provides access to different communication services of the PROFIBUS bus system: CP 342-5 FO Function The CP 342-5 FO provides access to different communication services of the PROFIBUS bus system: PROFIBUS DP (according to IEC 61 158/61784, master or slave) PG/OP communication S7

More information

SIMATIC S7-300. 4/2 Introduction. 4/4 Central processing units. 4/34 Digital modules. 4/44 Analog modules. 4/55 F digital /analog modules

SIMATIC S7-300. 4/2 Introduction. 4/4 Central processing units. 4/34 Digital modules. 4/44 Analog modules. 4/55 F digital /analog modules /2 Introduction / Central processing units /3 Digital modules / Analog modules /55 F digital /analog modules /61 Ex input/output modules /65 Function modules /65 FM 350-1 counter module /67 FM 350-2 counter

More information

CP 343-1 BACnet 6FL4343-1CX10-0XE0 DESIGO S7. Used with DESIGO S7, Building Solution & Building Integration

CP 343-1 BACnet 6FL4343-1CX10-0XE0 DESIGO S7. Used with DESIGO S7, Building Solution & Building Integration s 9 291 9291P01 DESIGO S7 CP 343-1 BACnet 6FL4343-1CX10-0XE0 Used with DESIGO S7, Building Solution & Building Integration SIMATIC S7.300 CP 343-1 for Industrial Ethernet TCP/IP with BACnet communications

More information

S7-1500/S7-1500F Technical Data

S7-1500/S7-1500F Technical Data CPU 1511-1 PN CPU 1513-1 PN CPU 1515-2 PN Type Standard CPU Standard CPU Standard CPU Dimensions 35 x 125 x 130 mm 35 x 125 x 130 mm 70 x 147 x 129 mm Spare part availability after 10 years 10 years 10

More information

SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved.

SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved. SIMATIC S7-1200 It s the Interplay that makes the difference SIMATIC S7-1200 Controller SIMATIC S7-1200 CPUs CPU 1211C 3 configurations per CPU Dimensions W x H x D (mm) CPU 1212C CPU 1214C DC/DC/DC, AC/DC/RLY,

More information

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE T I A Training Document Page 1 of 25 Module This document has been written by Siemens AG for training

More information

SIMATIC S7-400 advanced controller

SIMATIC S7-400 advanced controller Siemens AG 2015 /2 Introduction /4 Central processing units /4 Standard CPUs /4 CPU 412 /8 CPU 414 /13 CPU 41 /18 CPU 417 /21 SIPLUS Standard CPUs /21 SIPLUS S7-400 CPU 412 /22 SIPLUS S7-400 CPU 414 /23

More information

PROFINET the Industrial Ethernet standard. Siemens AG 2013. Alle Rechte vorbehalten.

PROFINET the Industrial Ethernet standard. Siemens AG 2013. Alle Rechte vorbehalten. the Industrial Ethernet standard is 100% Ethernet is Ethernet Ethernet is the established standard in the IT world for fast exchange of data (IEEE 802.3) is always full duplex simultaneous communication

More information

Siemens AG 2011. 3/42 Analog modules 3/42 EM 231 3/42 EM 232 3/42 EM 235 3/47 EM 231 thermocouple module 3/49 EM 231 RTD module

Siemens AG 2011. 3/42 Analog modules 3/42 EM 231 3/42 EM 232 3/42 EM 235 3/47 EM 231 thermocouple module 3/49 EM 231 RTD module Siemens AG 2011 /2 Introduction /4 Central processing units /4 CPU 221 /4 CPU 222 /4 CPU 224 /4 CPU 224 XP, CPU 224 XPsi /4 CPU 226 /24 SIPLUS central processing units /24 SIPLUS CPU 221 /25 SIPLUS CPU

More information

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL E04

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL E04 Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL PROFINET with IO Controller CPU 315F-2 PN/DP and IO Device ET 200S T I A Training Document Page 1 of

More information

SIMATIC NET. S7-CPs for PROFIBUS. CP 443-5 Basic. Manual Part B3

SIMATIC NET. S7-CPs for PROFIBUS. CP 443-5 Basic. Manual Part B3 SIMATIC NET S7-CPs for PROFIBUS Manual Part B3 CP 443-5 Basic 6GK7 443-5FX02-0XE0 Version 1 and higher (firmware version V4.0 and higher) for SIMATIC S7-400 / S7-400H Status and fault LEDs Mode selector

More information

Main Catalog 2012/2013 for specialists in automation and control technology

Main Catalog 2012/2013 for specialists in automation and control technology Main Catalog 2012/2013 for specialists in automation and control technology www.vipa.com Welcome to VIPA This is VIPA Specialists in automation and control systems. Developer in some to the most advanced

More information

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE E05

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE E05 Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE PROFINET with IO-Controller CP343-1 Advanced and IO-Device ET 200S T I A Training Document Page 1 of

More information

SOFTLINK 300. CPU Specifications. Reference Manual

SOFTLINK 300. CPU Specifications. Reference Manual SOFTLINK 300 Reference Manual This manual is part of the documentation Package with the order number 300 314-1SL01 300 314-2DP01 300 315-2DP01 Edition 04/2011 i Preface Purpose of the manual This manual

More information

SIMATIC. C7-621, C7-621 AS-i Control Systems. Volume 2 Working with C7 A B C D E. Contents. User Information. Introduction. Startup.

SIMATIC. C7-621, C7-621 AS-i Control Systems. Volume 2 Working with C7 A B C D E. Contents. User Information. Introduction. Startup. Contents User Information Introduction 1 Startup 2 SIMATIC C7-621, C7-621 AS-i Control Systems Volume 2 Working with C7 Manual Controlling Controlling with the C7 CPU 3 Addessing, Parameter Assignment,

More information

Overview and Applications of PROFINET. Andy Verwer Verwer Training & Consultancy Ltd

Overview and Applications of PROFINET. Andy Verwer Verwer Training & Consultancy Ltd Overview and Applications of PROFINET Andy Verwer Verwer Training & Consultancy Ltd What exactly is PROFINET? PROFINET is an open Industrial Ethernet standard developed by the PROFIBUS Organisation. PROFINET

More information

Operator Control and Monitoring Devices

Operator Control and Monitoring Devices Operator Control and Monitoring Devices Siemens AG 008 Overview Benefits Integral component of Totally Integrated Automation (TIA): Increased productivity, minimum engineering overhead, reduction in life-cycle

More information

PROFINET. The leading. Industrial. Ethernet. Standard. The Benefits of PROFINET

PROFINET. The leading. Industrial. Ethernet. Standard. The Benefits of PROFINET PROFINET The leading The Benefits of PROFINET Industrial Ethernet Standard Automation Structure 2 ))) Automation system Industrial Ethernet Automation Structure 3 Network standard Ethernet High transmission

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

DATA COMMUNICATION BETWEEN PROGRAMMABLE LOGIC CONTROLLERS IN THE INDUSTRIAL DISTRIBUTION APPLICATIONS

DATA COMMUNICATION BETWEEN PROGRAMMABLE LOGIC CONTROLLERS IN THE INDUSTRIAL DISTRIBUTION APPLICATIONS DATA COMMUNICATION BETWEEN PROGRAMMABLE LOGIC CONTROLLERS IN THE INDUSTRIAL DISTRIBUTION APPLICATIONS Anna BYSTRICANOVA 1, Andrej RYBOVIC 1 1 Department of Mechatronics and Electronics, Faculty of Electrical

More information

S7 CPs for Industrial Ethernet - SIMATIC NET. S7-300 - Industrial Ethernet S7 CPs for Industrial Ethernet - CP 343-1 Advanced.

S7 CPs for Industrial Ethernet - SIMATIC NET. S7-300 - Industrial Ethernet S7 CPs for Industrial Ethernet - CP 343-1 Advanced. S7 CPs for Industrial Ethernet - CP 343-1 Advanced SIMATIC NET S7-300 - Industrial Ethernet S7 CPs for Industrial Ethernet - CP 343-1 Advanced Manual Preface Properties and services 1 Performance data

More information

Technical Information POWER PLANT CONTROLLER

Technical Information POWER PLANT CONTROLLER Technical Information POWER PLANT CONTROLLER Content The Power Plant Controller offers intelligent and flexible solutions for the control of all PV power plants in the megawatt range. It is suitable for

More information

Cover sheet. Reading out the topology data of a PROFINET IO system SFB52 "RDREC" FAQ September 2009. Service & Support. Answers for industry.

Cover sheet. Reading out the topology data of a PROFINET IO system SFB52 RDREC FAQ September 2009. Service & Support. Answers for industry. Cover sheet Reading out the topology data of a PROFINET IO system FAQ September 2009 Service & Support Answers for industry. Question This entry originates from the Service&Support Portal of Siemens AG,

More information

Applications & Tools. Configuration of Messages and Alarms in WinCC (TIA Portal) WinCC (TIA Portal) Application description December 2012

Applications & Tools. Configuration of Messages and Alarms in WinCC (TIA Portal) WinCC (TIA Portal) Application description December 2012 Cover Configuration of Messages and Alarms in WinCC (TIA Portal) WinCC (TIA Portal) Application description December 2012 Applications & Tools Answers for industry. Siemens Industry Online Support This

More information

LOGO! Logic module. Brochures For brochures serving as selection guides for SIMATIC products refer to: http://www.siemens.com/simatic/ printmaterial

LOGO! Logic module. Brochures For brochures serving as selection guides for SIMATIC products refer to: http://www.siemens.com/simatic/ printmaterial Siemens AG 010 / / SIPLUS basic versions /5 SIPLUS Pure versions /8 analog expansion modules /9 SIPLUS expansion modules Brochures For brochures serving as selection guides for SIMATIC products refer to:

More information

PROFINET IO Diagnostics 1

PROFINET IO Diagnostics 1 PROFINET IO is a very cost effective and reliable technology. However, extensive installations can have thousands of PROFINET IO devices operating on many networks. The reliable operation of these networks

More information

SIMATIC NET. S7-CPs for Industrial Ethernet. CP 343-1 Lean. Manual Part B8. Version 1 or higher (Firmware Version V1.0) for SIMATIC S7-300 / C7-300

SIMATIC NET. S7-CPs for Industrial Ethernet. CP 343-1 Lean. Manual Part B8. Version 1 or higher (Firmware Version V1.0) for SIMATIC S7-300 / C7-300 SIMATIC NET S7-CPs for Industrial Ethernet Manual Part B8 CP 343-1 Lean 6GK7 343-1CX00-0XE0 for SIMATIC S7-300 / C7-300 Version 1 or higher (Firmware Version V1.0) LED displays TP port: 8-pin RJ-45 jack

More information

HARTING mcon 1000 Introduction and features

HARTING mcon 1000 Introduction and features Introduction and features HARTING mcon 1000 es, managed, for mounting onto top-hat mounting rail in control cabinets General Description Features Supporting Ethernet (10 Mbit/s), Fast Ethernet (100 Mbit/s)

More information

Product type designation. Display. Control elements

Product type designation. Display. Control elements Data sheet SIMATIC HMI, KTP700 BASIC DP, BASIC PANEL, KEY AND TOUCH OPERATION, 7" TFT DISPLAY, 65536 COLORS, PROFIBUS INTERFACE, CONFIGURATION FROM WINCC BASIC V13/ STEP7 BASIC V13, CONTAINS OPEN SOURCE

More information

AUSTRALIAN RAIL TRACK CORPORATION

AUSTRALIAN RAIL TRACK CORPORATION AUSTRALIAN RAIL TRACK CORPORATION INFRASTRUCTURE, STRATEGY AND PERFORMANCE Engineering Standards and Documents The following recommendation, together with the attached supporting documentation, has been

More information

RFID systems. Communications modules ASM 450 4/139. Overview

RFID systems. Communications modules ASM 450 4/139. Overview Overview The low-cost communications module ASM 50 is an autonomous PROFIBUS DP slave for the operation of MOBY components via the PROFIBUS DP: SIMATIC S7 (including FB/FC software) SINUMERIK SICOMP IMC,

More information

PROFINET Diagnostics Software and Tools

PROFINET Diagnostics Software and Tools PROFINET Diagnostics Software and Tools Dr. Xiu Ji Static wiring test, diagnostics Live system diagnostics Basics of PROFINET Content PROFINET Diagnostics by Dr. Xiu Ji, Page 2 What is PROFINET? PROFINET

More information

S7-1200 and STEP 7 Basic V10.5

S7-1200 and STEP 7 Basic V10.5 S7-1200 and STEP 7 Basic V10.5 S7-200 vs. S7-1200 Expandability S7-200 S7-1200 max. 7 Modules max. 3 Modules (CM) max. 8 Modules (SM) Page 2 Advantages of S7-1200, compared to S7-200 I/O Internal periphery

More information

Applications & Tools. Configuration and Diagnostics of a PROFINET IO System. PROFINET IO Configuration Example. Application Description January 2010

Applications & Tools. Configuration and Diagnostics of a PROFINET IO System. PROFINET IO Configuration Example. Application Description January 2010 Cover Sheet Configuration and Diagnostics of a PROFINET IO System PROFINET IO Configuration Example Application Description January 2010 Applications & Tools Answers for industry. Industry Automation and

More information

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8 CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps LEDs for display of supply voltage, group and bus errors as well as status and diagnostics Connection

More information

CPU 317-2 PN/DP: Configuring an ET. 200S as PROFINET IO device SIMATIC. PROFINET CPU 317-2 PN/DP: Configuring an ET 200S as PROFINET IO device

CPU 317-2 PN/DP: Configuring an ET. 200S as PROFINET IO device SIMATIC. PROFINET CPU 317-2 PN/DP: Configuring an ET 200S as PROFINET IO device CPU 317-2 PN/DP: Configuring an ET 200S as PROFINET IO device SIMATIC PROFINET CPU 317-2 PN/DP: Configuring an ET 200S as PROFINET IO device Introduction 1 Preparation 2 Learning units 3 Further Information

More information

1 Application Description... 3. 1.1 Objective... 3 1.2 Goals... 3

1 Application Description... 3. 1.1 Objective... 3 1.2 Goals... 3 Contents Moxa Technical Support Team support@moxa.com 1 Application Description... 3 1.1 Objective... 3 1.2 Goals... 3 2 System Topology... 3 3 Hardware and Software Requirements... 4 4 Configuration...

More information

Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master

Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master Page 1 of 13 Table of Contents 1 OVERVIEW... 3 2 INSTALLING AND CONFIGURING THE ANYBUS -X GENERIC GATEWAY AND ETHERNET

More information

SIMATIC NET. S7-CPs for Industrial Ethernet Configuring and Commissioning

SIMATIC NET. S7-CPs for Industrial Ethernet Configuring and Commissioning SIMATIC NET S7-CPs for Industrial Ethernet Configuring and Commissioning Manual Part A - General Application Preface, Contents Communication in S7 Stations 1 Characteristics of the Ethernet CPs 2 Commissioning

More information

HARTING econ 3000 Introduction and features

HARTING econ 3000 Introduction and features HARTING Introduction and features HARTING es, unmanaged, for installation in control cabinets General Description Features The Fast es of the product family HARTING are suitable for industrial applications

More information

Introduction to PROFIBUS and PROFINET

Introduction to PROFIBUS and PROFINET Introduction to PROFIBUS and PROFINET Andy Verwer Technical Officer for PROFIBUS UK Verwer Training & Consultancy Ltd Gold distributor PROFIBUS Characteristics PROFIBUS is a bi-directional digital communication

More information

Fieldbus slave modules with I/Os, DIO

Fieldbus slave modules with I/Os, DIO 140 Fieldbus slave modules with I/Os, DIO 1534CF00 1534CH00 1534PF00 1534PH00 1536CH00 1536CL10 1536PH00 1536PL00 Order number 1534CF00 1534CH00 1534PF00 1534PH00 Figure Type SM 153, CANopen slave, DIO

More information

Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University

Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University Practical steps for a successful PROFIBUS Project Presented by Dr. Xiu Ji Manchester Metropolitan University Basics of PROFIBUS Content Practical steps in the design and installation stages Segmentation:

More information

Temperature & Humidity SMS Alert Controller

Temperature & Humidity SMS Alert Controller Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal

More information

Configuring PROFINET

Configuring PROFINET CHAPTER 9 This chapter describes how to configure the PROFINET feature on the Cisco IE 3000 switch. Understanding PROFINET, page 9-1, page 9-4 Displaying the PROFINET Configuration, page 9-5 Troubleshooting

More information

FAQ Communication over IE

FAQ Communication over IE FAQ Communication over IE S7 communication between S7-200 and S7-300/400 FAQ Table of Contents Table of Contents... 2 Question...2 How do I configure a S7 connection to exchange data between S7-200 and

More information

SIMATIC Controllers. The innovative solution for all automation tasks SIMATIC. Answers for industry. Edition April 2013. Overview.

SIMATIC Controllers. The innovative solution for all automation tasks SIMATIC. Answers for industry. Edition April 2013. Overview. The innovative solution for all automation tasks SIMATIC Overview Edition April 2013 Answers for industry. System-wide engineering, communications and diagnostics SIMATIC Modular Controllers Your benefits

More information

TRAINING INDEX SIEMENS SIMATIC S7-200 S7-200 BASIC COURSE S7-200 ADVANCED COURSE SIEMENS SIMATIC S5 S5 STARTER S5 EXPERT

TRAINING INDEX SIEMENS SIMATIC S7-200 S7-200 BASIC COURSE S7-200 ADVANCED COURSE SIEMENS SIMATIC S5 S5 STARTER S5 EXPERT TRAINING INDEX SIEMENS SIMATIC S7-300/400 S7 BASIC COURSE S7 ADVANCED COURSE S7 ADVANCED DIAGNOSTICS S7 COMMUNICATION S7 ETHERNET S7 AS-I S7 OPC S7 PROFINET S7 LOOP CONTROL S7 GRAPH S7 SCL S7 DISTRIBUTED

More information

SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program Preface Contents SIMATIC NET CP 243-2 AS-Interface Master Manual Technical Description and Installation Instructions Interface to the User Program 2 in the S7-200 CPU Access to the Data of the AS-i Slaves

More information

SIMATIC S7-1200 Basic Controller in the TIA Portal

SIMATIC S7-1200 Basic Controller in the TIA Portal Technical slides SIMATIC S7-1200 Basic Controller in the TIA Portal Frei verwendbar / Siemens AG 2015. Alle Rechte vorbehalten. www.siemens.com/s7-1200 SIMATIC Controller S7-1200 Efficient engineering

More information

ET 200M. Introduction 9/191. Application. Technical specifications

ET 200M. Introduction 9/191. Application. Technical specifications Introduction Application Modular I/O system with IP20 degree of protection, particularly suitable for user-specific and complex automation tasks Can be expanded with S7-300 automation system signal, communication

More information

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2 Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male

More information

Permissible ambient temperature Operation Storage, transport

Permissible ambient temperature Operation Storage, transport The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems

More information

SIMATIC. S7-300 Programmable Controller Installation and Hardware. Preface, Contents. Product Overview 1. Mechanical Configuration 2

SIMATIC. S7-300 Programmable Controller Installation and Hardware. Preface, Contents. Product Overview 1. Mechanical Configuration 2 SIMATIC S7-300 Programmable Controller Installation and Hardware Manual This Manual is Part of the Documentation Package with the Order Number: 6ES7 398-8AA02-8BA0 Preface, Contents Product Overview 1

More information

Versions. Q.station Q.station T. Q.station D. Q.station DT x x

Versions. Q.station Q.station T. Q.station D. Q.station DT x x Most important features: Very high data rates up to 100 khz each channel 100 khz at 16 channels, 10 khz at 128 channels 64 Q.bloxx modules connectable Ethernet interface for configuration and data output

More information

PCS0100en 02.2008. Persy Control Services B.V. Netherlands

PCS0100en 02.2008. Persy Control Services B.V. Netherlands P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for

More information

SIMATIC S7-1500 advanced controller

SIMATIC S7-1500 advanced controller Siemens AG 2015 /2 Introduction /2 SIMATIC S7-1500/S7-1500F, SIPLUS S7-1500 /5 Central processing units /5 Standard CPUs /15 SIPLUS Standard CPUs /19 Fail-safe CPUs /28 /28 Digital modules /28 SM 521 digital

More information

SIMATIC. PROFINET IO Getting Started: Collection. CPU 317-2 PN/DP: Configuring PROFINET interface X2

SIMATIC. PROFINET IO Getting Started: Collection. CPU 317-2 PN/DP: Configuring PROFINET interface X2 SIMATIC PROFINET IO Getting Started: Collection CPU 317-2 PN/DP: Configuring PROFINET interface X2 CPU 317-2 PN/DP: Configuring an ET 200S as PROFINET IO device CP 443-1 Advanced: Configuration of the

More information

Lecture 4 Profibus. Urban Bilstrup Urban.Bilstrup@ide.hh.se

Lecture 4 Profibus. Urban Bilstrup Urban.Bilstrup@ide.hh.se Lecture 4 Profibus Urban Bilstrup Urban.Bilstrup@ide.hh.se Profibus Outline Introduction Profibus-DP Physical Layer Link Layer Application Layer 2 Profibus Introduction Three different versions of PROFIBUS

More information

Ha-VIS FTS 3000 Introduction and features

Ha-VIS FTS 3000 Introduction and features Ha-VIS Introduction and features Ethernet Switch Ha-VIS FTS 3100s-A 10-port Ethernet Switch with Fast Track Technology configurable via USB General Description Features The Fast Ethernet Switches of the

More information

CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC

CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC E031019 000823 systron S 200 - S 250 - S 250c CPU systron S 200 - S 250 - S 250c 45 mm width Flexible and expandable Easy to use software for bus connection (S 250/ S 250c) CPUs to the process modules

More information

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute

More information

Configuration limits for products of the SIMATIC NET PC Software V12 SIMATIC NET. Configuration limits for products of the SIMATIC NET PC Software V12

Configuration limits for products of the SIMATIC NET PC Software V12 SIMATIC NET. Configuration limits for products of the SIMATIC NET PC Software V12 Configuration limits for products of the SIMATIC NET PC Software V12 Communications partners and configuration limits for HARDNET-PB DP-Base 1 software Configuration limits, SOFTNET-PB DP 2 SIMATIC NET

More information

Parameterization, Configuration and Visualization with SIRIUS

Parameterization, Configuration and Visualization with SIRIUS Parameterization, Configuration and Visualization with SIRIUS Price groups 200, 346, 42B, 42C, 42D, 42H, 42J, 4N1 /2 Introduction /5 Soft Starter ES /9 SIRIUS 3RW44 soft starter block library for SIMATIC

More information

SIMATIC NET. S7-CPs for Industrial Ethernet. CP 343-1 Lean. Manual Part B. Release 09/2009 C79000-G8976-C198-06

SIMATIC NET. S7-CPs for Industrial Ethernet. CP 343-1 Lean. Manual Part B. Release 09/2009 C79000-G8976-C198-06 SIMATIC NET S7-CPs for Industrial Ethernet Manual Part B CP 343-1 Lean 6GK7 343 1CX10 0XE0 as of hardware version 2, as of firmware version V2.2 for SIMATIC S7 300 / C7 300 LEDs TP port: 2 x 8-pin RJ-45

More information

SIMATIC NET. Functions (FC) and function blocks (FB) for SIMATIC NET S7 CPs. Preface. Overview and general information on working with FCs and FBs

SIMATIC NET. Functions (FC) and function blocks (FB) for SIMATIC NET S7 CPs. Preface. Overview and general information on working with FCs and FBs Preface Overview and general information on working with FCs and FBs 1 SIMATIC NET Functions (FC) and function blocks (FB) for SIMATIC NET S7 CPs Programming Manual FCs / FBs for Industrial Ethernet 2

More information

154 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370 Main Office: (650) 588-9200-Outside Local

154 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370 Main Office: (650) 588-9200-Outside Local 154 PHOENIX CONTACT PROFINET The future-oriented system solution PROFINET is the realtime Ethernet approach that can be used in all industrial motion control fields - from factory automation to process

More information

How-To-Do. Hardware Configuration SLIO CPU 014

How-To-Do. Hardware Configuration SLIO CPU 014 How-To-Do Hardware Configuration SLIO CPU 014 With the SIMATIC Manager from the SIEMENS AG Content 1 General... 2 1.1 Information... 2 1.2 Reference... 2 2 Step by step Hardware Configuration... 3 2.1

More information

SNMP Web Management. User s Manual For SNMP Web Card/Box

SNMP Web Management. User s Manual For SNMP Web Card/Box SNMP Web Management User s Manual For SNMP Web Card/Box Management Software for Off-Grid Inverter Version: 1.2 Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2 Features... 1 1.3 Overlook...

More information

PROCESS AUTOMATION PLANNING AND INTEGRATION INFORMATION LB8106* Integration in Siemens SIMATIC PCS 7

PROCESS AUTOMATION PLANNING AND INTEGRATION INFORMATION LB8106* Integration in Siemens SIMATIC PCS 7 PROCESS AUTOMATION PLANNING AND INTEGRATION INFORMATION LB8106* Integration in Siemens SIMATIC PCS 7 With regard to the supply of products, the current issue of the following document is applicable: The

More information

Hirschmann Networking Interoperability in a

Hirschmann Networking Interoperability in a Automation and Network Solutions Hirschmann Networking Interoperability in a PROFInet Environment Hirschmann Interoperability White Paper Rev. 1.1 Contents Hirschmann Networking Interoperability in a Profinet

More information

SIMATIC S7-1200 basic controller

SIMATIC S7-1200 basic controller Siemens AG 2015 /2 Introduction /4 Central processing units /4 Standard CPUs /4 CPU 1211C /8 CPU 1212C /12 CPU 1214C /16 CPU 1215C /20 CPU 1217C /2 SIPLUS standard CPUs /2 SIPLUS CPU 1211C /26 SIPLUS CPU

More information

S7 for Windows S7-300/400

S7 for Windows S7-300/400 S7 for Windows S7-300/400 A Programming System for the Siemens S7 300 / 400 PLC s IBHsoftec has an efficient and straight-forward programming system for the Simatic S7-300 and ern controller concept can

More information

Automating with STEP 7 in STL and SCL

Automating with STEP 7 in STL and SCL Berger Automating with STEP 7 in STL and SCL Automating with STEP7 in STL and SCL Programmable Controllers SIMATIC S7-300/400 by Hans Berger 6 th revised and enlarged edition, 2012 Publicis Publishing

More information

C7 Control Systems PLC and Operator Panel in one device. Product Brief November 2003

C7 Control Systems PLC and Operator Panel in one device. Product Brief November 2003 C7 Control Systems PLC and Operator Panel in one device Product Brief November 2003 Overview, advantages, innovation SIMATIC C7 control systems comprising SIMATIC OP & S7-300 SIMATIC OP SIMATIC S7-300

More information

INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS. 1. Features. 2. Description

INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS. 1. Features. 2. Description INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS stam-irs_en 01/11 STAM-IRS is a dedicated server to be used with the STAM-2 monitoring station which enables receiving transmissions sent via telephone

More information

SIMATIC NET. AS-Interface - Introduction and Basics A B. Preface, Contents

SIMATIC NET. AS-Interface - Introduction and Basics A B. Preface, Contents Preface, Contents SIMATIC NET AS-Interface - Introduction and Basics Manual AS-Interface (AS-i) 1 AS- Interface Safety at Work (ASIsafe) 2 AS-i System Components 3 The Master Mode - Commands, Sequence,

More information

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy

More information

CANtrol EC Modular Control System Powerful and versatile

CANtrol EC Modular Control System Powerful and versatile Controls CANtrol EC Modular Control System Powerful and versatile CANtrol EC The modular control system Components of CANtrol EC 1 EC1000 Ethernet Controller 2 E-I/O EtherCAT I/O family communicating controlling

More information

SIMATIC. STEP 7 From S5 to S7. Preface, Contents Part 1: Planning Your Conversion. Introduction. Hardware. Converter Manual.

SIMATIC. STEP 7 From S5 to S7. Preface, Contents Part 1: Planning Your Conversion. Introduction. Hardware. Converter Manual. SIMATIC STEP 7 Converter Manual Preface, Contents Part 1: Planning Your Conversion Introduction 1 Hardware 2 Software 3 Part 2: Converting Programs Procedure 4 Preparing for Conversion 5 Conversion 6 Editing

More information

6AV3617-1JC30-0AX1. Type of voltage. UPS connectable (serial) Backup battery. minimum backup duration Memory. Flash / RAM.

6AV3617-1JC30-0AX1. Type of voltage. UPS connectable (serial) Backup battery. minimum backup duration Memory. Flash / RAM. 6AV3617-1JC30-0AX1 Page 1 Product data sheet 6AV3617-1JC30-0AX1 OPERATOR PANEL OP17/DP12 LC DISPLAY, BACKLIT LED 4X20/8X40 LINESXCHARACTERS SIMATIC S5, 505, S7, M7, NATIVE DRIVERS, PROFIBUS-DP 12 MBAUD,

More information

DCS Data and communication server

DCS Data and communication server 8 58 PLD.TOWER PLD.RACK VISONIK DCS Data and communication server PLD.TOWER PLD.RACK Data and communication servers (DCS) are used as management stations in building automation and control (BAC). With

More information

SIMATIC PCS 7. SIMATIC Maintenance Station PDM A stand-alone Solution. Siemens AG 2011. All Rights Reserved.

SIMATIC PCS 7. SIMATIC Maintenance Station PDM A stand-alone Solution. Siemens AG 2011. All Rights Reserved. SIMATIC PCS 7 SIMATIC Maintenance Station PDM A stand-alone Solution SIMATIC Maintenance Station PDM Use Independent Maintenance Station of a used Distributed Control System (DCS) or Process Logic Controller

More information

VIPA System 500S. SPEED7 - CPU 515-2AJ02 Manual

VIPA System 500S. SPEED7 - CPU 515-2AJ02 Manual VIPA System 500S SPEED7 - CPU 515-2AJ02 Manual HB145E_CPU RE_515-2AJ02 Rev. 10/23 June 2010 Copyright VIPA GmbH. All Rights Reserved. This document contains proprietary information of VIPA and is not to

More information

PROFINET IRT: Getting Started with The Siemens CPU 315 PLC

PROFINET IRT: Getting Started with The Siemens CPU 315 PLC PROFINET IRT: Getting Started with The Siemens CPU 315 PLC AN-674 Application Note This document shows how to demonstrate a working design using the PROFINET isochronous real-time (IRT) device firmware.

More information

Factory Automation SIMATIC LOGO!..0BA6. Colin Limbert. Factory Automation Department. Product Manager LOGO! and S7-200

Factory Automation SIMATIC LOGO!..0BA6. Colin Limbert. Factory Automation Department. Product Manager LOGO! and S7-200 SIMATIC LOGO!..0BA6 Colin Limbert Department Product Manager LOGO! and S7-200 LOGO!..0BA6 Innovated hardware Overview Innovated inputs LOGO! TD text display 3 new plug-in cards LOGO!..0BA6 Overview LOGO!..0BA6

More information

OPERATOR PANEL OP7/DP LC DISPLAY, BACKLIT LED 4 LINES, 20 CHARACTERS/LINE, SIMATIC S7, M7, PROFIBUS-DP 1.5 MBAUD UL/CSA-LISTED

OPERATOR PANEL OP7/DP LC DISPLAY, BACKLIT LED 4 LINES, 20 CHARACTERS/LINE, SIMATIC S7, M7, PROFIBUS-DP 1.5 MBAUD UL/CSA-LISTED 6AV3607-1JC20-0AX1 Page 1 Product data sheet 6AV3607-1JC20-0AX1 OPERATOR PANEL OP7/DP LC DISPLAY, BACKLIT LED 4 LINES, 20 CHARACTERS/LINE, SIMATIC S7, M7, PROFIBUS-DP 1.5 MBAUD UL/CSA-LISTED Supply voltage

More information