HP 16/18-Port Cable Management Kit Installation Guide



Similar documents
HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide

HP UPS R1500 Generation 3

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

Rack Installation Instructions

Installation. Basic Rack Power Distribution Unit for Blade Servers

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

UPGRADING AND SERVICING GUIDE

Wall-Mounting your HP computer. User Guide

RACKMUX-DRAWER Installation Manual For Drawer with 20 Inch LCD Monitor

Rack installation instructions

About the BitStorm 6051 POTS Splitter

Cable management for rack-mounted systems

Step 1. Item 6. Item 1

HP ProLiant DL165 G7 Server. Installation Instructions

HP Laser Jet 4200/4240/4250/4300/4350 Swing Plate

Raritan LCD KVM Console (T1700/T1900)

Small form factor bay converter and hard drive installation

Upgrading and Servicing Guide

PS6500 Storage Arrays Rack Mount Instructions

PRS X-axis E-chain installation: For tools with a 12 Z-Axis

FL ADJUSTABLE RIDER BACKREST MOUNTING HARDWARE KIT

POWER LOCK KIT GENERAL INSTALLATION -J04427 REV Kit Number. Models. Additional Parts Required. Kit Contents

Raritan LCD KVM Console (T1700/T1900)

Gripper Kit for the Boe-Bot Robot (#28202)

Service Guide. Gateway M275

GPS AutoSteer System Installation Manual

Rack Installation Instructions

SPRITE and BIGFOOT DESKTOP CNC MACHINE KIT ASSEMBLY INSTRUCTIONS

Upgrading a GainMaker Line Extender from a Line-Powered Source to a 120 V AC-Powered Source Installation Instructions

GENUINE PARTS INSTALLATION INSTRUCTIONS

Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances

HP SATA/SAS hard drive and Solid State Drive installation

The power module is Feature Number 8800-F2-901.

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in

Unpacking, Installation, and Customization

Memory Modules User Guide

Scale Computing Storage Cluster Installation Guide. Scale Computing 2121 S. El Camino Real San Mateo, CA

Power Distribution Systems for the Dell PowerEdge M1000e Modular Server Enclosure - Selection and Installation

Spreader Light Bulb Replacement Instructions

CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions

Installation Guide. Wyse D Class 4-GB RAM Upgrade Option Kit. Products: D90D7, D90DW. Issue: PN: L Rev. A

About this Manual. Support for Your Product

Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009

Installation. Smart-UPS VT and MGE Galaxy Maintenance Bypass Panel with Power Distribution (wall-mount) kva 208 V

Compaq Presario Desktop Products. Upgrading and Servicing Guide

UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M To mount outer member to rack

4RU High Density Shelf Installation Instructions

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

42U/45U 28" Wide Rack Installation & Service Guide

GSM-EXT Cable Assembly Installation Guide

INSTALLATION INSTRUCTIONS

R O A D M A S T E R, I N C.

Standard Sleep Pod Side Entry Assembly Instructions

Front Panel Board Cable Replacement Instructions

Installing Your 960 or 980 Server into a Rackmount Cabinet

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

TOYOTA TUNDRA 2015 Billet Grille w/led DRL

Base Cabinet Assembly Instructions

ilan Ethernet Box for 9100 Installation Manual

LG G5 Chassis Brace Gen 5 Camaro THE MOST POWERFUL HEADERS ON THE PLANET Brought to you by LG Motorsports

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

Mazda CX up B

FRONT TURN SIGNAL RELOCATION KIT

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

Contractors Guide Central Inverter System Installation

SALEEN SPEEDLAB SERIES VI STANDARD SC UPGRADE KIT

R O A D M A S T E R, I N C.

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

AU-110 racking guide NBXPN: 023

Tyan Computer. Transport PX22. Service Engineer s Manual

Elecraft K3 KPA3 Power Connector Replacement Revision A Review, April 16, 2012 Copyright 2012, Elecraft, Inc. All Rights Reserved

Installation instructions, accessories - Handsfree for cellular phone, system B, entry level

R O A D M A S T E R, I N C.

Written By: Walter Galan

CETAC Z-Drive Assembly

TOYOTA TACOMA HANDS FREE BLU LOGIC Preparation

HP R12000 and R18000 DirectFlow UPS User Guide

Memory Modules. Document Part Number: This guide explains how to replace and upgrade memory in the computer. May 2006

Rail Kit Install Guide: Intel Modular Server System MFSYS25 A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products

UniStream CPU-for-Panel

AstroSystems Digital Setting Circles for Zhumell, GSO, Apertura and Astro-Tech

R O A D M A S T E R, I N C.

Parts Required: Remove the Falcon Wiper Motor:

Set Up Your MXI -Express x1 System

Installation Instructions

Out-of-box comparison between Dell, HP, and IBM blade servers

KEYPAD LOCK RETROFIT KIT

430 Power/Electronics Replacement

Kiosk Group, Inc. ASSEMBLY INSTRUCTIONS FOR THE STANDALONE. EXQUISITE ipad KIOSK. For ipad Version Tablets.

SERVICE MANUAL. Corpus 3G. Seat system for electric wheelchair

TASK: Restring or Replace Cord Lock for Cellular, Pleated or Roman Shades

R O A D M A S T E R, I N C.

About the HotWire Slot Standalone Shelf

R O A D M A S T E R, I N C.

MCR1900 Media Converter 19-Slot Chassis

Dell P Series Monitor VESA Mounting Bracket Installation Instructions

P150SC15. Designed for 2015 Ford F150 Super-Cab and Super-Crew vehicles without Sony System Stillwater Designs P150SC15-A

Part Name/Description Part Number Quantity. Power Cable

Implementing the HP Cloud Map for SAS Enterprise BI on Linux

Transcription:

HP 16/18-Port Cable Management Kit Installation Guide Abstract This document describes how to attach the HP 16 Port or 18 Port Cable Management Kit to an HP rack. The cable management bracket is designed to align and support the cables that lead from an HP BladeSystem c-class enclosure's 16 port or 18 port InfiniBand switch mounted in the rear of the chassis to another c-class InfiniBand switch or an InfiniBand interconnect installed in an adjacent rack. The cable management bracket currently supports the HP BLc QLogic 4X QDR InfiniBand Switch (505958-B1) and the HP BLc 4X FDR InfiniBand Switch (64831-B1), but it can potentially be used for other configurations, as deemed necessary. HP Part Number: 5387-doc Published: April 01 Edition:.0

Copyright 009, 01 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. InfiniBand is a trademark of the InfiniBand Trade Association.

Contents 1 Preparing for Installation...4 1.1 Audience...4 1. Documentation Resources...4 1.3 Kit Description...4 1.4 Kit Contents...4 1.5 Required Resources...5 1.6 Prerequisites...6 Aligning the Bracket...7 3 Installing the Cable Management Bracket...9 3.1 Installing the Cable Management Bracket...9 3. Installing the Releasable Cable Ties for the InfiniBand Cables...9 4 Removing InfiniBand Cables and Switches...1 4.1 Removing a Damaged Cable From the c-class Cable Management Bracket...1 4. InfiniBand Switch Removal...1 Contents 3

1 Preparing for Installation 1.1 Audience This guide is intended for HP service representatives and other persons trained to install hardware options in HP racks. Such persons are expected to understand the hazards of working in this environment and to take suitable precautions to minimize danger to themselves and others. 1. Documentation Resources You can download the documentation for components referenced in this installation guide from the following locations: HP Rack (Documentation option): http://h18004.www1.hp.com/products/servers/proliantstorage/racks HP Cluster Platform: 1.3 Kit Description http://docs.hp.com/en/highperfcomp.html The c-class enclosure cable management bracket described in this manual is designed to align and support the InfiniBand cables that lead from an HP c-class InfiniBand switch module. For example, the InfiniBand cables that run from a HP c-class switch module mounted in the rear of the HP BladeSystem c-class enclosure to another switch, or a similar interconnect device. The kit provides strain relief for the cables connected to the individual InfiniBand interconnect ports and ensures a good connection. It also ensures the correct bend radius for the cable and provides channels for cable routing and cable management. One cable management kit is required for each interconnect module bay system interconnect device. NOTE: The cable management bracket is designed to support 4 AWG (0.41 inch) diameter, 6 AWG (0.37 inch) diameter, and 8 AWG (0.33 inch) diameter QSFP InfiniBand cables. Consult the documentation supplied with your cluster before installing the brackets and routing the cables. 1.4 Kit Contents Verify that the cable management bracket kit contains the following components: Packaging and documentation. The bracket hardware shown in Figure 1. 4 Preparing for Installation

Figure 1 Bracket Hardware 1 3 4 5 6 The following list describes the callouts in Figure 1: 1. HP 16-Port or 18-Port Cable Management Bracket. Releasable cable tie 3. Holes used for the push-button mounts 4. Push-button mount 5. Rail-mount hook (one on each end of the bracket) 6. Mounting hole to fasten the bracket to the rack's rear rail (one on each end of the bracket) The fasteners that are specified in Table 1. Table 1 Fasteners (Supplied with Cabinet Mounting Hardware) Qty. Size Format Torque Description M6 cage nuts Square nut N/A Cage nut for M6 screw. M6 x 16mm pan head screws Posidrive 5-30 in/lb Machine screw. For use with M6 cage nut. To prevent screws from becoming loose because of vibration, HP recommends that you use an adjustable torque drive, set to the torque specifications given in the table above. Contact your HP sales representative if any parts are missing. 18 push-button mounts (see callout 4 in Figure 1) 18 releasable cable ties (see callout in Figure 1) Note: This cable management bracket might also be adaptable for other cable management solutions (consult your hardware installation documentation). 1.5 Required Resources To install the HP cable management kit, you require the following resources: Tools: Screwdriver, # (medium) Phillips Cage-nut insertion tool (shipped with the rack) or a flat-headed screwdriver 1.5 Required Resources 5

Marker pen or masking tape Diagonal cutting pliers Resources: Cables of the type used by the HP BladeSystem c-class InfiniBand switch. 1.6 Prerequisites Before you begin to mount the bracket: Follow the usual cable-handling precautions for InfiniBand cables, see the InfiniBand switch manual that came with your switch. Ensure you know how to plug in the InfiniBand cables, as described in the InfiniBand switch manual that came with your switch. Read the rack installation instructions for the c-class enclosure. Obtain the set of cabling tables required for your HP InfiniBand network. Important: Do not secure the enclosure into the rack before you begin the bracket installation. You must be able to access the rear (inward) face of the rack columns. 6 Preparing for Installation

Aligning the Bracket Figure shows the correct orientation of the cable management bracket which you must install before connecting the cables to the InfiniBand switch module. During the cabling procedure, the bracket provides strain relief for the InfiniBand ports, and maintains the correct minimum cable bend radius. Figure Bracket Orientation 1 The following list describes the callouts shown in Figure : 1. Mounting hook installed in one of the mounting holes in the rack's rear left column. Cable management bracket Callout 1 shows the bracket's mounting hook installed in one of the square holes in the left rear rack column. The actual mounting locations for a bracket are relevant to the location of the c-class enclosure in the rack, and must align with the InfiniBand switch installed in the c-class enclosure. Figure 3 shows the relative mounting locations. Figure 3 Three Bracket Mounting Locations U10 1 U9 U8 U7 U6 3 4 The following list describes the callouts shown in Figure 3: 7

1. The U location that aligns with the top of the HP BladeSystem c7000 enclosure. Each c7000 enclosure is 10U high.. Mounting hook location (black square) and fastener location (circled square) for an InfiniBand switch installed in Interconnect Module Bays (IMB) 3 and 4 3. Mounting hook location (black square) and fastener location (circled square) for an InfiniBand switch installed in IMB 5 and 6 4. Mounting hook location (black square) and fastener location (circled square) for an InfiniBand switch installed in IMB 7 and 8 Use the following procedure to determine the actual mounting locations for brackets: 1. Determine which of the interconnect module bays contain the InfiniBand switch. Note: There might be more than one InfiniBand switch module in some configurations.. Determine the rack U location that aligns with the top of the c-class enclosure. 3. Using a pen or masking tape, mark the mount locations defined in Table. Table Bracket Mounting Locations HP BladeSystem c7000 Enclosure Interconnect Module Bay Numbers Relative U Location Bracket Hook Cutout Fastener Cutout 3 and 4 Third U down from the top of the c-class (c7000) enclosure Bottom cutout Top cutout of the fourth U down from the top 5 and 6 Fourth U down from the top of the c-class (c7000) enclosure Center cutout Bottom cutout of the fourth U down from the top 7 and 8 Fifth U down from the top of the c-class (c7000) enclosure Top cutout Center cutout of the fifth U down from the top 8 Aligning the Bracket

3 Installing the Cable Management Bracket The location of the cable management bracket depends on the rack position occupied by the HP BladeSystem c-class enclosure. The InfiniBand switch might be installed in any or all of the interconnect module bays identified in Table. 3.1 Installing the Cable Management Bracket Use the following procedure to install the HP BladeSystem c-class enclosure cable management bracket: Caution: When performing the installation procedure, extend only one c-class enclosure no more than a few inches from the rack at any time. Ensure that the rack is stable before you begin the installation procedure. Note: One cable management kit is required for each InfiniBand switch installed in the rear of the c-class enclosure. 1. Starting from the lowest bracket location, and using the fastener locations that you identified and marked in Chapter, clip a cage nut into the back of each rear rack column.. Hook the bracket onto the square cutouts in the rack column. 3. Fasten the bracket to the rear rack columns by using two M6 pan-head screws and tighten them to the specified torque. 4. If more than one bracket is required, repeat Step 1. 5. Slide the c-class enclosure back into the rack and secure it at the front of the rack as specified in the installation instructions for the enclosure. 6. If necessary, attach the second bracket once the first switch (lowest switch in the c7000 enclosure) is cabled and tie-wrapped. Note: HP recommends that you only install the cable management bracket for the lowest InfiniBand switch in the c-class enclosure and complete the cable installation. Doing so makes it easier to install the releasable cable ties for each of the InfiniBand cables. Once the releasable cable ties are installed for the InfiniBand cables coming from the switch installed in the lowest interconnect module bay, you must install the next cable management bracket and releasable cable ties for the next InfiniBand switch. It is necessary to complete the installation for the lowest bracket first because there is not enough space between the two brackets to secure the releasable cable ties for the lower bracket when two or more brackets must be installed. 3. Installing the Releasable Cable Ties for the InfiniBand Cables Figure 4 shows the holes in the bracket that are used in the cable management bracket for an InfiniBand switch with 16 external uplink ports. 3.1 Installing the Cable Management Bracket 9

Figure 4 A Cable Management Bracket Holding 16 InfiniBand Uplink Cables 1 3 The following list describes the callouts shown in Figure 4: 1. Left rear rack column. 16 secured InfiniBand cables 3. One of the 16 releasable cable ties (completed assembly for 16-port switch shown) Important: You must install the HP BladeSystem c-class enclosure cable management bracket to provide proper strain relief for the InfiniBand cables. To install the InfiniBand cables and secure them with the releasable cable ties, follow these steps: 1. Install the push-button mounts by pressing them upward into each hole in the cable management bracket (see callout 4 in Figure 1).. Cable the lower InfiniBand switch first, as described in the hardware installation guide for the switch. 3. To secure an InfiniBand cable (callout 1 in Figure 5) to the cable management bracket, slide the releasable cable tie through the push button mount and around the InfiniBand cable (see callout in Figure 5) and through the releasable cable tie lock. 10 Installing the Cable Management Bracket

Figure 5 InfiniBand Cable Secured with a Releasable Cable Tie 1 Caution: The releasable cable tie should only be hand tight. Do not use a cable tie installation tool and do not over tighten the releasable cable tie or it might damage the InfiniBand cable. 4. Leaving approximately 1/4 inch to 3/8 inch coming out of the buckle, clip the excess from the releasable cable tie. Use one of the clipped-off pieces of cable tie as a tightness gauge (see callout 1 in Figure 6) to check that there is room to allow the InfiniBand cable (callout 4 in Figure 6) to move freely in the releasable cable tie loop (callout 3 in Figure 6) that is secured to the cable management bracket (callout in Figure 6) with a push button mount (not shown in Figure 6). Figure 6 Gauging the Tightness of the Releasable Cable Tie Loop 3 4 1 5. Repeat steps 4 and 5 to secure the remaining InfiniBand cables. 6. Route the InfiniBand cables to the side of the rack and secure them either upward or downward in the cable management plate. Be sure not to exceed the cable manufacturer s recommended bend radius for each InfiniBand cable as you route them in the rack. 3. Installing the Releasable Cable Ties for the InfiniBand Cables 11

4 Removing InfiniBand Cables and Switches This chapter describes the procedure to remove a damaged InfiniBand cable or InfiniBand switch for repair. 4.1 Removing a Damaged Cable From the c-class Cable Management Bracket To remove a damaged cable, follow these steps: 1. Bring the HP BladeSystem c-class enclosure to an appropriate state for service as described in the HP BladeSystem c7000 Enclosure Maintenance and Service Guide on the HP website: http://h0000.www.hp.com/bc/docs/support/supportmanual/c0071437/ c0071437.pdf. To release the InfiniBand cable from the releasable cable tie, use your finger or a small flat-headed screw driver to push down on the small tab inside the cable tie lock (see callout 1 in Figure 7). Figure 7 Cable Tie Release Tab 1 Note: The release tab is very small and might be difficult to reach with your finger. Use a small flat-headed screw driver to push the tab down to release the cable tie. Also, because there are several cables, removal of an InfiniBand cable in the middle portion of the switch might be difficult without the use of needle nose pliers and a small flat-headed screw driver. Be very careful not to damage other InfiniBand cables while using pliers or a screw driver. 3. Remove the InfiniBand cable from the switch. To remove the InfiniBand cable, pull the release tab on the QSFP connector while using your other hand to remove the connector from the switch. For more information on how to remove an InfiniBand cable from the switch, see the HP BLc QLogic 4X QDR InfiniBand Switch Installation Guide. 4. InfiniBand Switch Removal Put the rack cabinet into a safe and stable state for component removal. You must ensure that you can reach the component easily and handle it safely. To remove the InfiniBand switch, follow these steps: 1. Bring the HP BladeSystem c-class enclosure to an appropriate state for service as described in the HP BladeSystem c7000 Enclosure Maintenance and Service Guide on the HP web site: http://h0000.www.hp.com/bc/docs/support/supportmanual/c0071437/ c0071437.pdf. Remove all of the InfiniBand cables from the InfiniBand switch, but leave them secured in the cable management bracket. 3. Remove the cable management bracket from the rack's rear mounting rails. 1 Removing InfiniBand Cables and Switches

4. Leave the cables secured in the cable management bracket and carefully set the bracket aside. Caution: Do not bend the InfiniBand cables more than the minimum bend radius recommended by the cable manufacturer. 5. Push the blade handle release button to release the blade handle. 6. Open the blade handle and slide the switch all the way out of the HP BladeSystem c7000 enclosure. 4. InfiniBand Switch Removal 13

*5387-doc* Printed in the US