SA-1 SMOKE ALARM installation & user guide



Similar documents
Thesis Format Guidelines. Department of Curriculum and Instruction Purdue University

5/12/2011. Promoting Your Web Site and Search Engine Optimization. Roger Lipera. Interactive Media Center.

How to Extend your Identity Management Systems to use OAuth

CONTENTS. 03 BRAND IDENTITY 04 Logo 06 Wordmark 07 Graphic Element 08 Logo Usage 13 Logo Elements

Practicing Law with a Virtual Law Office

franchise applications

Responsive Design

Creative GUIDELINES

Cincinnati State Admissions UX Design

Identity Guidelines. by SMARTBEAR

University at Albany Graphic Identity Manual

Custom Software & Web Design

Content Strategy. Content Management

Branding Guidelines CONEXPO Latin America, Inc (Rev-1)

Desktop Publishing (DTP)

KNOWLEDGE TRANSFER, CONTINUITY, AND DOCUMENTATION

English. Italiano. Français

Bold Future 2007 Building our Company with the needs of future generations in mind Activity Report 2007

Appy Kids: The Best Apps for Pre-Schoolers

The Future of Ticketing: Solutions for Museums of All Sizes

SAVE UP TO $750 ON REGISTRATION

A Step by Step Guide to Creating an App. by Carter Thomas, Bluecloud LLC

I WORK FOR UX PORTFOLIO GUIDANCE

ANNUAL REPORT 2012 ARION BANK ANNUAL REPORT

DevOps: Extending Agile Development Disciplines to Deployment IBM Corporation

Bill Pay Marketing Program Campaign Guide

Introduction to HTML/XHTML Handout Companion to the Interactive Media Center s Online Tutorial

The views expressed in this publication are those of the authors and do not necessarily represent those of Lumina Foundation, the Bill and Melinda

8 Ways Marketing Automation Can Expand Your Search Marketing Practice. 8 Ways Marketing Automation Can Expand Your Search Marketing Practice 1

The views expressed in this publication are those of the authors and do not necessarily represent those of Lumina Foundation, the Bill and Melinda

UNIVERSITY OF AGDER JUNE 2012 COLLABORATIVE CODING OF QUALITATIVE DATA WHITE PAPER LA2020. Peter Axel Nielsen

No Frills Magento Layout. Alan Storm

Creator Coding Guidelines Toolbox

Disclosure Obligations of Issuers of Municipal Securities

EVENT PLANNING MYTHBUSTER. Building Pre-event Engagement: How to Make an Invite

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

FLOOD SENSOR. perfection in every detail. Home intelligence. Patent Pending

Combi B Alarm box. Mounting instructions

DMA MARKETING BRIEF B2C DIRECT MARKETING PROFESSIONALS EVERY WEEK MEDIA KIT

Quick Start Guide For Vera Small Business Solution

Concept. Texting Service

GSM ALARM SYSTEM GCM 8

Structured Product Labeling (SPL) Implementation Guide with Validation Procedures

CAA NEWS 15,000 VISUAL ART PROFESSIONALS REACH EVERY WEEK MEDIA KIT

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

Modern Web Apps with HTML5 Web Components, Polymer, and Java EE MVC 1.0. Kito Mann Virtua, Inc.

Morningstar Newsletter Builder

TS93 EMR T/PT/TDE. Surface applied door closer

AD-01 Slave Auto Dialer. Owner s Manual

Quick Start Guide For Vera Advanced Home Security Solution

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

AC-115 Compact Networked Single Door Controller. Installation and User Manual

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

SMART SENSOR COLLECTION

MODELS 8007 Gorilla Cycle Alarm 8017 Gorilla Cycle Alarm with 2-way pager system way pager system

MODELS 7007 Gorilla Cycle Alarm 7017 Gorilla Cycle Alarm with 2-way pager system way pager system

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

ANTI-THEFT SYSTEM Volvo 850 DESCRIPTION & OPERATION BASIC ALARM ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems

Basic Website Maintenance Tutorial*

D287/D288/D292/D293A/D293E

CAD-05 Kit GSM Auto Dialer. Owner s Manual

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

Cellular Edition TM- CELL400 User Guide. 1 TM- CELL400 Rev Temperature@lert

TS510 & TS500. Installation & User Guide. Compatible Equipment

Heat Surge Model X5C Fire Place Insert Service Manual Applies to all units w/ circuit board

Battery Wall Controller. Manual

INSTALLATION MANUAL VEHICLE SECURITY SYSTEM CE-SS200

-Helping to make your life betterwww.person-to-person.net

Intermediate STEMSEL Project 6 Light Sensor Alarm

ม มมองสามด านท ต องหาจ ดสมด ล. Powerpoint Templates

SECTION DETECTION AND ALARM

Pre-Registration Consumer DSL/FiOS. Storyboard / /31/09

Manual for Fire Suppression & Methane Detection System

AUTODIALLER / QUICKDIALLER - SA132

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

User Manual. Updated for igrill and ios 7

ZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8

SOFT DRINKS. Demo General Report. Report Monthly Oct 30, Nov 28, 2013

Application/Connection Examples

ACADEMIC ACCELERATOR PROGRAM STUDENT HANDBOOK

site monitoring Kit Site Monitoring Kit User Manual we prove it.

3 Slot Payphone Controller

INSTRUCTION MANUAL All-In-One GSM Home Alarm System SB-SP7200-GSM

WAMLocal. Wireless Asset Monitoring - Local Food Safety Software. Software Installation and User Guide BA/WAM-L-F

UM-X Field display for continous level sensors

LW A. Wireless Auto Dial Alarm System. Sentry Plus User Manual By Global Gadgets

Modular I/O System Analog and Digital Interface Modules

Alarm Security Kit - NVR

Running head: USING ACCEPTABILITY AS A MEASURE FOR ONLINE EDUCATION 1. Using Acceptability as a Measure for Evaluating Online Education

WIRING HARNESS FOR AS635P4. BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness

Wireless Auto-dial Intruder Alarm System

GSM ALARM SYSTEM USER MANUAL

MOUNTING AND OPERATING INSTRUCTIONS

ERS-2400B. PERS-2400B Personal Emergency Reporting System

Shunt lock function 3066

Wireless Alarm System. Alarm Siren. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

Transcription:

SA-1 SMOKE ALARM installation & user guide

SA-1 Smoke Alarm A smoke alarm is an excellent safety device and with the IT Watchdogs SA-1, not only will you have the usual audible alarm signal if something in your installation begins to smoke, but your WeatherGoose monitoring system will be able to notify you via e-mail or SNMP as well, just like any other monitored sensor! This makes the SA-1 an especially valuable add-on for monitoring remote installations which might not have anyone around to hear the siren. Plus, since the Kidde smoke alarms the SA-1 is based around are capable of being connected to other smoke alarms as a group, such that if one senses smoke, they all sound off (a very important feature for large commercial buildings where a single alarm wouldn t be loud enough to be heard throughout the facility), an SA-1 can be wired up alongside other compatible Kidde smoke alarms such that any smoke alarm in your facility can trip the alarm threshold on the WeatherGoose unit and send an alert. (In fact, it is exactly this remote daisy-chaining function which the SA-1 taps into in order to provide a signal to the WeatherGoose; the actual Kidde smoke alarm device is not modified by IT Watchdogs in any way.) The SA-1 is directly compatible with any WeatherGoose (series I or series II) monitoring unit which has analog-sensor inputs; such models include the WeatherGoose, SuperGoose, and the MiniGoose/XP. Models which do not have built-in analog inputs, such as the MiniGoose, will require the use of an appropriatelyprogrammed CCAT analog-to-digital converter to use an SA-1. Models which do not provide connections for either analog or digital sensors, such as the MicroGoose, are not compatible with the SA-1 Smoke Alarm. A typical example of the SA-1 Smoke Alarm is shown below. Note that because the SA-1 is based around a standard off-the-shelf Kidde smoke alarm, your particular unit may have some cosmetic differences from the one shown below. Its functionality, however, will be the same. SA-1 Smoke Alarm users guide Rev. A-101 (Oct. 2010) 1

The SA-1 is powered both by a 120VAC wall plug, and by a 9V backup battery which keeps the unit alive and functioning in the event of a line-power failure. This means that as long as your WeatherGoose and its associated network & internet gateways are also kept alive via a UPS or auxiliary generator during a power failure, then you will still receive e-mails and/or SNMP trap events if smoke should be detected. CAUTION: the SA-1 is not designed for worldwide-voltage operation, and is not compatible with 208VAC or 240VAC line voltages! The Kidde smoke alarms that the SA-1 is designed around are only rated and sold for use in North America, and are only designed to function on standard 120VAC/60Hz line voltages. Attempting to operate the SA-1 from higher voltages, and/or from 50Hz line frequencies, may permanently damage or destroy the smoke-alarm unit. As with any smoke alarm device, IT Watchdogs strongly recommends that you make a note of when the SA-1 was first installed, test it at regular intervals, and replace it on the schedule recommended by the smoke alarm s manufacturer. The manufacturer s recommended testing and replacement schedules can be found on the body of the smoke alarm itself; simply twist the smoke alarm to unlock it from the mounting base (an arrow molded into the plastic body will show the correct direction), then look at the manufacturer s labeling on the back of the unit. twist the smoke alarm unit to dismount it from the base... Lorem ipsum dolor sit amet, consectetur adipisicing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum....remove the smoke alarm unit from the base......and follow the manufacturer s periodic testing and replacement recommendations listed on the back of smoke alarm unit This same procedure can be used to access the battery compartment to install or change the 9V backup battery, if yours is one with the battery compartment located on the back of the unit. (The location of the battery compartment may vary depending on smoke alarm model.) Be certain to follow all manufacturer s recommendations as to how to open the battery compartment, and how often the battery should be changed. 2

Connecting the SA-1 to the Analog-Input terminals: The following diagrams demonstrate how to connect your SA-1 Smoke Alarm directly to the spring-loaded analog-input terminals used on most of the standard series-i and series-ii WeatherGoose product lines. (Note that specialized models, such as the PowerGoose and RelayGoose, use different styles of terminal blocks; while the connections will be the same electrically, the mechanical nature of the connector will be different than the one shown here. If necessary, refer to the manuals for those specific models for further details on how to connect analog sensor devices.) Each terminal consists of two openings; a larger, square opening at the bottom, where the wire will be inserted, and a smaller, narrower opening above which is used to open the spring-loaded jaws inside the terminal block so the wire can be inserted. Note that the terminal jaws are not of an insulation-piercing type, and the wire ends must be stripped at least ½ prior to insertion. First, insert a small flatblade screwdriver into the upper slot......pry upwards to open the spring-loaded jaw......slip the sensor wire into the larger bottom opening......then pull out the screwdriver to allow the jaw to close around and grip the wire. Red wire (+) can go into any numbered terminal This diagram shows the correct polarity to connect an SA-1 to the analog-input terminals on a WeatherGoose. Note that this applies to all models of the WeatherGoose family, regardless of series or model; the SA-1 must be connected with the correct polarity, or the unit will not function and the Goose s input circuitry could be damaged by incorrect connections! C 1 2 3 C CAUTION: unlike some types of analog sensors, the SA-1 cannot be doubled up ; i.e. you cannot connect two or more of them in series or parallel so that they share a single analog input! Attempting to do so can damage both the sensors, and possibly the WeatherGoose analog inputs as well! Black wire (-) can go into either C (common) terminal 3

Sensor operation and behavior: Once you ve successfully connected the SA1 to your WeatherGoose, the internal-sensors display block of the Sensors page will look something like this: (NOTE: for purposes of this example, the SA-1 has been connected to Analog Input #1 of a WeatherGoose-II with v3.3 firmware; the use and operation of the SA-1 will be similar for other models, but the on-screen displays may differ somewhat.) In this screenshot, the SA-1 is currently dormant; no smoke has been detected, so the alarm is quiet and there is no signal to the WeatherGoose... So, if the alarm is inactive, why does the reading show 99, instead of 0 as you might normally assume? This is just a consequence of the way the internal Analog Inputs are designed to accommodate both dry-contact devices such as switches, relays, etc., and voltage-signal devices such as current transformers. Since the SA-1 presents itself as a dry-contact type of device, the analog input reads 99, because its contacts are currently in the open state and, due to the presence of a weak pull-up resistor which supplies loop current for dry-contacts connected to the Analog Input terminals, an open terminal will tend to float up to +5V and since the WeatherGoose displays the Analog Inputs 0~5VDC input range as a proportional value from 0~99, an open contact pair reads as 99. Here, the smoke alarm has detected smoke in the air (or someone has held down the test button), and the SA-1 s contacts have closed. Note that the reading hasn t quite gone all the way to 0, but that s not unusual; depending on the length of the wire between the WeatherGoose and the SA-1, there may be a few ohms of resistance in the wire that keep the input from getting all the way down to 0VDC. (Oxidization on the wire terminals can also cause this, which is why it is important to ensure that the wires are cleanly stripped and that the WeatherGoose unit is not mounted in an area which is exposed to excessive humidity or airborne chemical contaminants. Since the SA-1 is simply a Yes/No -type of sensor, though, a slight variation in readings doesn t matter effectively, any reading >50 can be considered inactive, and anything <50 can be read as alarm. 4

Alarm-threshold settings when connected directly to an Analog Input: If you are using a Series-II unit: To set an alarm threshold to notify you when a door is opened, simply go to the Alarms page, click the button under the Goose s internalsensors block, Analog Input to which the RCP2-100 is connected (Analog-1 in this example), set to Below and threshold to 50; then, set the checkboxes for the alarm actions you wish this alarm threshold to trigger, along with a trigger delay or alarm-repeat interval if desired, and click. If you are using a Series-II unit with a firmware revision prior to v3.4.x, your alarm-settings block will look like this. Alarm-threshold settings are calculated and programmed the same way as above; the only difference (aside from the lack of trigger-delay and alarm-repeat intervals, which were introduced in v3.4) is that the alarm types are named High Trip and Low Trip instead of Above and Below, respectively. High Trip alarms are tripped when the reading goes higher than the set threshold, while Low Trip alarms are tripped when the reading goes below the threshold. If you are using a Series-I unit: The alarm thresholds are the same as for series-ii, but the method of setting them is somewhat different. Find the sensor block on the Alarms page for the Goose unit s internal sensors, then set the threshold to 50 and the threshold to 110, as shown here, for the input which the SA-1 is connected to, then set the to the action you wish to take place when the trip threshold(s) are exceeded and click. (The input being used is highlighted here for example purposes.) Since the Analog input cannot go higher than 99, this will effectively disable the High Trip event, which is not needed in this application. 5

BK RD Connecting the SA-1 to the CCAT-SMOKE: If you are using an ITWatchdogs monitoring device which does not have built-in analog inputs, such as the MiniGoose-II, or if you have already used up all of your analog inputs on other sensors, then you will need to attach the SA-1 via an appropriately-programmed CCAT analog-to-digital bus interface module, available from IT Watchdogs. The following diagrams show how to hook up and use an SA-1 in combination with a CCAT-SMOKE interface module. (Note: the CCAT has been manufactured in a couple of different physical variations over the lifetime of the product. If your CCAT does not seem to match the appearance of the one shown below, you may have an earlier model, and may wish to consult the CCAT User Guide to insure the correct hookups.) Note that the same cautions apply to using the CCAT as to the internal Analog Inputs; i.e. correct polarity must be observed when connecting the SA-1, and multiple units may not be connected in series or parallel to share a single CCAT connection! Again, the wires will need to be stripped, as the terminals are not of an insulationpiercing type. However, they do not need to be stripped back as far as they do for the Analog Input block; a ¼-inch of exposed wire will generally be sufficient for the style of terminals used on the CCAT. red wire goes into the terminal marked RD or (+) black wire goes into the terminal marked BK or (-) 6

Sensor operation & behavior when connected via a CCAT-SMOKE: Once you ve connected the CCAT-SMOKE to the monitoring unit, a new sensor block will appear, initially titled Smoke Sensor. (This name can, of course, be changed from the Display page to something more specific to your installation.) If your CCAT does not initially display as Smoke Sensor, do not proceed further, as your CCAT is not correctly programmed for this sensor and will not display its status properly! (In this event, contact IT Watchdogs technical support for assistance.) This screenshot shows an inactive smoke alarm, so the WeatherGoose displays the SA-1 s status as Clear. The actual numeric value being graphed is 99 this is because the CCAT s A/D converter behaves essentially the same way as the built-in Analog Inputs on the WeatherGoose; i.e. an open dry-contact input tends to float to 5VDC due to an internal pull-up resistor, and 5V is interpreted and displayed as 99. However, since the CCAT and WeatherGoose know that the connected device is supposed to be an SA-1 smoke alarm, it is able to interpret the number and present a more user-friendly display. Now, let s see what happens when we activate the smoke alarm. The numeric reading drops down towards 0, and the SA-1 s status is indicated as Smoky. (If you are conducting a test of the SA-1, you will probably want to hit refresh on your browser a few seconds after the alarm begins to sound, rather that wait for the automatic 1-minute page refresh.) Special note for series-i WeatherGoose users: Series-I models will not display the smoky or clear labels described above; instead, they will simply display the same numeric values as described in the previous section on analog inputs, as shown here. NOTE: THERE IS A BUG IN SOME OLDER SERIES-II FIRMWARE VERSIONS WHICH CAUSES THE UNIT TO DISPLAY THE STATUS INCORRECTLY; i.e. the Smoky and Clear states are reversed! This does not affect the device s actual operation or the ability to set alarm thresholds; it is merely a cosmetic issue with the friendly naming of the actual numeric values from the CCAT-SMOKE. However, it can be confusing, so if you find that your device is displaying the SA-1 s status opposite of what it should be, IT Watchdogs highly recommends updating your unit to the latest firmware revision at the soonest opportunity. 7

Alarm-threshold settings when connected via a CCAT-SMOKE: If you are using a Series-II unit: When you go to the Alarms page, you ll find that a new parameter block has been added there as well, also titled Smoke Sensor. To set an alarm threshold to notify you when the SA-1 detects smoke and sounds the alert, simply scroll down to this new parameter block, click the button, set to Below and threshold to 50; then, set the checkboxes for the alarm actions you wish this alarm threshold to trigger, along with a trigger delay or alarm-repeat interval if desired, and click. If you are using a Series-II unit with a firmware revision prior to v3.4.x, your alarm-settings block will look like this. Alarm-threshold settings are calculated and programmed the same way as above; the only difference (aside from the lack of trigger-delay and alarm-repeat intervals, which were introduced in v3.4) is that the alarm types are named High Trip and Low Trip instead of Above and Below, respectively. High Trip alarms are tripped when the reading goes higher than the set threshold, while Low Trip alarms are tripped when the reading goes below the threshold. If you are using a Series-I unit: The alarm thresholds are the same as for series-ii, but the method of setting them is somewhat different. Find the sensor block on the Alarms page for newly-connected CCAT-SMOKE, then set the threshold to 50 and the threshold to 110, as shown here, then set the to the action you wish to take place when the trip threshold(s) are exceeded and click. Since the reading on a CCAT analog-to-digital input channel cannot go higher than 99, this will effectively disable the High Trip event, which is not needed in this application. 8