Platte River Interceptor Slipline Rehabilitation



Similar documents
Storm Sewer Trenchless Upgrade Alternatives and Recommendations

SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO)

ENGINEERED SOLUTIONS. A2 Liner Pipe for Trenchless Technology

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

San Antonio, TX July 28, 2011

CONSTRUCTION OF NON-CIRCULAR SEWER REHABILITATION PROJECTS IN LOS ANGELES

Sewer Pipe Lining An Economic Solution for Pipe Rehabilitation By Tawana Albany Nicholas, Virgin Islands Waste Management Authority

Summary 7/11/2012. Michigan Water Environment Association 2012 Annual Conference Boyne Mountain Resort

Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe

Annular Space Grouting of Slipline Products

NON-CIRCULAR SEWER LINER INSTALLATION AND FUTURE PROJECTS IN LOS ANGELES

San Antonio Water System Standard Specifications for Construction ITEM NO POINT REPAIRS AND OBSTRUCTION REMOVALS

Repair or Replacement - Band-Aids vs. Surgery

UNDERGROUND INFRASTRUCTURE SPECIALISTS TABLE OF CONTENTS

Session: HDPE Pipe Test Rafael Ortega, Vice President, Lockwood, Andrews & Newnam

Waste Collection Systems

Rehabilitation or Replacement? That Is The Question

12/8/2014. Brought To You By: This webcast is sponsored by NASSCO with the support of IPBA.

SECTION 21 REHABILITATION OF SANITARY SEWER MAINS BY THE PIPE BURSTING AND TRENCHLESS PIPE REPLACEMENT METHOD

Sewer Rehabilitation Design Requirements

Installation of Large Diameter Buried Pipes

REHABILITATION OF THE LONG WHARF SEWER FORCE MAIN USING SLIPLINING METHODOLOGY IN NEWPORT, RHODE ISLAND

SECTION IX SLIP LINING PIPELINES

CLEANING, INSPECTION, AND TESTING OF SEWERS

SEWER CLEANING, INSPECTION AND ASSESSMENT

Emerging Technologies in Wastewater Collection Systems

High Density Polyethylene Liners for Rehabilitation of Corroded Pipelines

LOWER NORTH OUTFALL SEWER AND NORTH OUTFALL SEWER REHABILITATION USING AMERON S T HAB METHOD

CCTV PIPE INSPECTION AND EVALUATION RUNWAY 17L-35R

Sewer Line Rehabilitation

by Leonard Friesenhahn, P.E.

San Antonio Water System Standard Specifications for Construction ITEM 866 SEWER MAIN TELEVISION INSPECTION

53.03 MATERIALS FOR SEWER LINER PIPE AND FITTINGS: The following materials are approved for installation in sanitary sewer lines:

Rehabilitation Alternatives. MWEA Collection System Seminar October 1, 2009

REHABILITATION OR REPLACEMENT? THAT IS THE QUESTION

Mainline Pipe Rehabilitation Using Cured-in-Place Pipe (CIPP) & Folded Pipe Technology

TECHNICAL NOTE Culvert Sliplining and Lining of Casings with HPPipe

CHALLENGES IN LINING A 100 YR OLD BRICK SEWER

The Environmental Implications of Road Culvert Repair Technologies. Bridget Donaldson Senior Research Scientist

Water Transmission & Sewer Force Main Renewal 16 through 60

A Revolution for Telecom, Electric, Gas, & Water"

Pipe Bursting. Case Study at Zeeland, MI Collections Seminar September 6, Presentation Agenda. What is Pipe Bursting? What is Pipe Bursting?

Coast Trunk Sewer Rehabilitation Project for the Orange County Sanitation District

1.3.2 Method of construction and restoration of existing water service connections. This shall include:

REVIEW OF TRENCHLESS TECHNIQUES FOR THE REHABILITATION OF SEWERS. Gerhard (Gerry) P. Muenchmeyer, P.E. Muenchmeyer Associates, LLC

INSTALLATION OF INSITUFORM LINER

SECTION 802 GRAVITY SEWER PIPE

Waste Management. Infrastructure Rehabilitation in the U.S. Virgin Islands

McGOEY, HAUSER and EDSALL CONSULTING ENGINEERS D.P.C.

SPR PE Steel Reinforced Liner

Wastewater Collection System Supplemental Design Standards for Capital Improvement Program Projects

CHAPTER 6 - SANITARY SEWER

FY08 SEWER POINT REPAIRS BID TABULATION

Section 402. STORM SEWERS

MIAMI-DADE LATERAL PILOT PROGRAM. James T. Cowgill, P.E. Rodney J. Lovett Franklin Torrealba, P.E.

CITY OF BEVERLY RULES AND REGULATIONS - SEWER SYSTEM TESTING. General

TABLE OF CONTENTS. Manhole, Frame, and Cover Installation (includes Drop Manhole) Additional Manhole Depth

Panel Lok Pipe Renovation System Danby LLC (formerly Danby of North America, Inc.) Waterfront Mall - 90 Diameter Rehabilitation

PORTLAND BES ADVANCES IN SEWER MAINTENANCE AND REPAIRS BY OPERATING MULTIPLE CIPP CREWS.

Section SEWER PIPE INSTALLATION AND TESTING

Utilizing Remaining Useful Life for Asset Management of Critical Wastewater Assets

SECTION POINT REPAIRS TO SANITARY SEWERS. A. Repairs to existing sewer lines by replacing short lengths of failed pipe.

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

THE ECOLOGICAL IMPLICATIONS OF TRENCHLESS PIPE REHABILITATION

Special Specification 7021 Water Main and Sewer Line Replacements

FY15 Gravity Sewer and Manhole Rehabilitation

PROVIDING THE SAFE CHOICE FOR UNDERGROUND PIPE RENEWAL, INTEGRITY MANAGEMENT AND ASSET RELIABILITY

Trenchless Construction Technology and Issues

CITY OF DAYTON DEPARTMENT OF WATER 42-INCH SANITARY SEWER REHABILITATION

CW GRAVITY SEWERS TABLE OF CONTENTS

SECTION IV - TESTS AND INSPECTIONS PART 1 - GENERAL Testing - General

SECTION STORM DRAINAGE TABLE OF CONTENTS

FY11 Sanitary Sewer Main Rehab and Point Repair Bid Tabulation

BEST PRACTICE GUIDELINES FOR CULVERT LINER SELECTION

Dewatering - Time and Cost Relief by way of Trenchless Construction

City of Hilshire Village Pine Creek Ln Reconstruction

SECTION 724 PIPE CULVERTS

ATTACHMENT 3: SPECIFICATION FOR SEWER CLEANING

Water Main Lining A Sustainable Alternative to Open Cut Replacement

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

SECTION 3 SANITARY SEWER DESIGN

PART 6 - STANDARD DESIGN AND CALCULATION FORMS 6.1 SANITARY SEWER DATA SHEET

NORTH DAVIS SEWER DISTRICT STANDARD COLLECTION DETAILS

The leader in trenchless rehabilitation

A. Contractor shall furnish, to the Engineer, all materials certifications available from the manufacturer for all required materials.

Introduction to Pressure Pipe Rehabilitation with CIPP

PRODUCT CATALOGUE. for. SMARTPHONE / WEBSITE / DIGITAL EDITION / BOOK / ipad / GPS

Flowtite Jacking Pipe

City of Balch Springs, Texas. Request for Proposal (RFP ) Pipe Bursting Sewer Line Replacement

REHABILITATION OF UNDERGROUND SEWER LATERAL PIPES WITH CURED-IN-PLACE-PIPE LINER SECTION 02542

Memorandum. PROJECT: Postmark Emergency Storm Repair Alternative Analysis

Transcription:

Platte River Interceptor Slipline Rehabilitation Owner: Metro Wastewater Reclamation District Contractor: American West, Denver CO Slipline Pipe Manufacturer : Hobas Pipe USA Presented by: Tom Furie, Area Manager Southwest, Hobas Pipe USA

Sliplining: What Is It? 2

44 ( OD 45.9 ) Inside 48 Host 3

4

5

Sliplining Overview : Issues and Concerns O Liner Diameter Fit O5% Annulus Typical O Host Undersized O Joint Offsets, Grade & Alignment of Host Pipe O Verify with Madrel Before Insertion of Liner Pipe O Joint Selection, Low Profile vs/ Flush OCondition of Host Pipe, Not Fully Clean? ODesired Clearance 6

Steel Mandrel Fabricated by Contractor 7

Pit Locations O At PI s (Points of Intersection ) O Adjacent to Curves or Manholes O Specify Denied Area s (Owner) O Shallow Locations are Preferable O Distance Limitations, How Far to next PI? 8

Sliplining Pit Locations Compact! 9

Sliplining Pit Locations May Require Creativity! 10

Above Ground Slipline 72 CCFRPM Inside of 78 Steel 11

Pushing Distances and Curves O 2,000 to 3,000 typical, longest push know 5,600 (51 into 57 ) O Distances Depend on Pipe Material (CCFRPM, PVC, HDPE) O Curves Require Short Pipes(3,5,10 )/ Smaller Diameter OUse of CIPP in Curves OFittings Carried- In or / Dig up and Replace 12

LAX Airport: 4700 feet of 48 pipe pushed from one pit. Less than 25 tons to push 500 tons of pipe. 13

Pipe Insertion O Cleaning Line No Obstructions OPoint Repairs O Mandrel Proof Before Insertion of Liner O Pusing Pipe with Pushing Ring (The Easy Part!) ORates of up to 240 per Hour in Live Flow OLateral Connections O Video Confirmation 14

Lateral Connections 15

Grouting and Inspection O Collapse Pressure Grouting Contractors O Floatation ( Best with Ballast of Sewage & Lightweight Grout) O Bulkhead at Manholes Pushing Sewage from Annulus O Video Inspection Confirmation of No Damage OLeak Testing O Close out Pit Locations, Closure Couplings 16

DOT Road Culvert Before Grouting 17

Flow Recovery

Sliplining not limited to Large Diameter Pipe! 18 Inside of 20 Host 19

Slipline Live in L.A 1,400 Feet Rehabilitated in 6 Hours 20

Platte River Interceptor Rehab OProject Necessary Because Infiltrartion Tests Showed Joints Leaking. O 78 RCP Sewer Transmission Line / 150 Leaking Joints. O Metro Dist Spent $300,000 to Repair Joints/ $18,0000 each ORepairs Unsuccessful OGlobal Solution Desired by Metro Dist - Leak Free Pipe. O Project Designed by Metro Dist Engineering. 21

Platte River Interceptor Rehab OScope: Rehabilitate 2,030 of 78 RCP & 3 Manholes and Associated Fittings. ( Trenchless & Open Cut) OProject Bid Competitively Between Slipline and CIPP O District had Luxury of Diverting Flow on the Line. O Low Bidder: America West Construction Inc. Denver CO O Construction Cost: $1,338,981 O Method Chosen by America West Construction: Slipline 22

Houston Factory Host Pipe in Good Condition. Pushing Pit does not require containment with Dry Line. 23

72 CCFRPM - Flush Joint Slipline Pipe 24

Lightweight 72 Liner Pipe ( OD 75.4 ) weight 330 lbs/ft 25

Liner Pipe being Pulled In 26

Confined Space, Sliplining Close to River and Bike Path

Houston Factory Use of Steel Push Ring 28

Using Bucket to Push Pipe Not Rocket Science 29

Point of Intersection, Fitting Location 30

Tee Base Manhole/ FRP Riser 31

Pushing Both Directions From The Same Pit! 32

Advantages to Sliplining - HOBAS OImproved Flow Capacity (increased hydraulics) OMany Oddball Pipe Diameter to choose (27, 33, 41 ) ODone in Live Flow No By Pass Pumping =$$$ O High Strength Pipe Longer Pushes = Fewer Pits O Joint (Low profile vs. Flush) and Pipe Length Options O Easy to Grout with Higher Safety Factors O Visual Inspection of Liner Before Insertion OPipe is Designed to be Stand Alone O Significant History of Supplying Slipline Pipe 33

HOBAS PIPES are your best value Thank you