Reverse-feed applications for circuit breakers



Similar documents
Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

Evaluating Water-Damaged Electrical Equipment

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

SELECTION OF FINAL CIRCUIT PROTECTION

CIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS

Determining the Cause of AFCI Tripping Branch/Feeder and Combination Arc Fault Circuit Interrupters Class 760

STANDARDS AND RATINGS FOR THE APPLICATION OF MOLDED CASE, INSULATED CASE, AND POWER CIRCUIT BREAKERS

Circuit Breakers. Next Generation of Protection Capabilities

Miniature Circuit Breakers and Supplementary Protectors

Application of Four-Pole Circuit Breakers within Data Centers

Evaluating Water-Damaged Electrical Equipment

Evaluating Water-Damaged Electrical Equipment

Siemens STEP 2000 Course Basics of Electrical Products

The Application of Circuit Breakers to Reduce Downtime in Datacentres

Bolted contact switches. Pringle switches

Inverter / Charger Installation General Operations and AC and DC Connections

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems

Atlanta Chapter IEEE Industry Applications Society

SENTRON Switching and Protection Devices Air Circuit Breakers

Mining service breakers with true rms sensing designed specifically for trailing cable applications

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

How To Test A Power Switch On A Power Supply

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

Fundamentals of Power

Bypass transfer switch mechanisms

Guidelines on the Short Circuit Current Rating for Industrial Control Panels

Engineering Series Ratings: Is It Practical?

Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600

, User s Manual

Eaton s E-Series protective relay family

ELECTRICAL SAFETY. The standard unit for measuring electrical current.

Electrical Grounding. Appendix C

Corner-Grounded Delta (Grounded B Phase) Systems

misconceptions about arc-flash hazard assessments

101 BASICS SERIES LEARNING MODULE 3: FUNDAMENTALS OF ELECTRICAL DISTRIBUTION. Cutler-Hammer

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

Help protect your home, possessions and family.

City of Riverside Building & Safety Division Phone: (951)

Oil and Coolant Circulating Heating System. Model - OCSM

PORTABLE GENERATORS AND OSHA CONSTRUCTION REGULATIONS

GUIDELINES FOR WATER-DAMAGED ELECTRICAL EQUIPMENT

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Protect your home and family with Advanced Technology from Cutler-Hammer

Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves

Comparison of NEMA and IEC schematic diagrams

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.

CONSIDERATIONS FOR INSTALLATION OF SMOKE ALARMS ON RESIDENTIAL BRANCH CIRCUITS

Sentron Series Circuit Breakers

Unified requirements for systems with voltages above 1 kv up to 15 kv

Fault Characteristics in Electrical Equipment

OPTIMIZING POWER SYSTEM PROTECTION FOR MODERN DATA CENTERS

ZONE SELECTIVE INTERLOCKING (ZSI) APPLICATION AND TESTING GUIDE SIEMENS WL UL489 AND UL1066 AIR CIRCUIT BREAKERS

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

Evaluating Fire- and Heat-Damaged Electrical Equipment

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

Engineering innovation

Mission Critical Data Center Systems

Primary and Secondary Electrical Distribution Systems

Simplified Guide To Understanding Short-Circuit Current Rating FIND IT, FIX IT, FORGET IT

Secondary Unit Substations

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope

Top Commercial / Residential Electrical Requirements *

Introduction. Upon completion of Basics of Switchboards you should be able to: Explain the role of switchboards in a distribution system

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

Contents. Description. Product Selection Guide

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

HAZARDS, INCLUDING SHOCK, ARC FLASH AND FIRE

County of Riverside Building and Safety Department

Electrical Wiring Methods, Components and Equipment for General Use. Approved for Public Release; Further Dissemination Unlimited

Short Circuit Current Calculations

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

Choosing the Best Solution for Reducing Arc Energy

Extension Cord Safety Policy

Safety By Design. Strategies for Electrical Contractors

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Enphase Microinverters and Ungrounded Renewable Energy Systems: Canadian Electrical Code Compliance

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

NEC 2014 Code Changes

Nothing s BetterThan the Original MODAN Power Distribution Systems

Electrical Shore Connections / Cold Ironing

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

Circuit Breaker. Description

Application Bulletin NEC Reference Guide for SolarBridge-Enabled AC Module Installers

CITY OF LOS ANGELES CALIFORNIA

Circuit Breakers Supplementary Protectors Manual Motor Controllers

THERMAL MANAGEMENT SOLUTIONS

Molded case circuit breakers

Tmax MCCBs. Molded case circuit breakers. Tmax

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

INSTALLATION & SERVICE MANUAL. Display Panel

Transcription:

Technical Publication PU01200001E Contents Description Page Intoduction.......................................................................... 2 breaker classifications.......................................................... 2 Standards requirements................................................................ 2 UL 489 Molded case circuit breakers, molded case switches, and circuit-breaker enclosures....... 2 Testing requirements............................................................... 2 Marking requirements............................................................... 3 UL 1066 Low voltage AC and DC power circuit breakers used in enclosures.................... 3 Special application considerations........................................................ 3 breakers with integral ground-fault protection........................................ 3 Molded case circuit breakers with external ground-fault/earth leakage accessories................ 4 Miniature circuit breakers with integral ground-fault and arcing-fault protection..................... 5 Summary............................................................................ 6

Technical Publication PU01200001E Introduction breakers may be applied in panelboard, switchboard, or motor control center installations where there may occasionally be multiple sources of power, as shown in Figure 1. For example, these may be applications that require high uptime and high reliability requirements. For these requirements, permanent, fixed mount, or portable electrical generator systems, with an appropriate automatic transfer switching system, are made available to supplement the normal utility power supply source. In other instances, the second power source may be from a so-called alternate energy source, such as that derived from solar photo-voltaic or from wind power electric systems. Similarly, these alternate energy sources are also typically connected as a supplement to the normal utility power sources. As electrical load demand conditions change, the user may switch between using power from the normal utility source to the alternate power source, and vice versa. Whenever this switch in power source occurs, the terminals of the circuit breaker that the power is connected to will have been reversed. This reversal in the way that power is connected to a circuit breaker is called reverse-feed. Reverse-feed (or back feed ) refers to a way that the conductors supplying current are connected to a circuit breaker. This May Be Reverse-Fed Depending on Its Connection to Either of the Utility Power Sources Utility #1 52 NC NO Bus #1 52 Utility #2 52 52 52NC Bus #2 Standards requirements UL 489 Molded case circuit breakers, molded case switches, and circuit breaker enclosures Per UL 489, there are clear test performance and marking requirements and molded case switches that are UL Listed as being suitable for reverse-feed applications. UL 489 requires reverse-feed circuit breakers to meet certain construction requirements, and to be tested and marked accordingly, as follows: 1. Tested per UL 489, Paragraph 7.1.1.18 2. Markings per UL 489, Paragraph 9.1.1.13 Testing requirements Per UL 489, Paragraph 7.1.1.18: Except for single-pole circuit breakers tested singly, if a circuit breaker is not marked Line and, one sample of each set tested, or one additional sample, shall be connected with the line and load connections reversed during the overload, endurance and interrupting tests. This UL test requirement specifies that and molded case switches to be UL Listed for reverse-feed applications, samples shall be tested with the line and load terminals reverse-fed, as shown in Figure 2, and that the test results shall be the same as those of normally fed circuit breakers. Depending on the design configuration and construction, the circuit breaker may or may not be affected by the application of power in. a reverse-feed connection during these tests. Top Side of Power Source Connected to Top Side of Figure 1. Fed from Multiple Power Supply Sources In other applications where there is a single power source,. circuit breakers may be mounted in an electrical enclosure where the cables from the power source are fed to the bottom of the enclosure. In this case, it may be a matter of convenience for the installation to simply connect the power source conductors to the terminals at the bottom of the circuit breaker that are closest to the incoming power supply conductors. This connection of the power supply source to the circuit breaker s bottom terminals will also result in power being applied in a reverse-feed manner. There are different classifications and types of circuit breakers. that exist, and they should be carefully considered when used in reverse-feed applications described above. Depending on the type. of circuit breaker, as listed below, reverse-feeding of that circuit breaker may or may not be suitable for that application. Power Source Connected to Bottom Side of Bottom Side of Figure 2. Connections for Reverse-Feed Testing per UL 489 breaker classifications Low voltage circuit breakers fall into two basic classifications. of design. 1. Molded Case s (MCCBs). per ULT 489 Standard 2. Low Voltage Power s (LVPCBs). per UL 1066 Standard 2

Technical Publication PU01200001E Marking requirements Per UL 489 Paragraph 9.1.1.13: breakers shall be marked Line and unless the construction and test results are acceptable with the line and load connections reversed. This marking requirement specifies that UL Listed circuit breakers and molded case switches shall be marked with the word Line on one end of the circuit breaker and the word on the other end, as shown in Figure 3, if they are unable to successfully meet the reverse-feed test requirements per Paragraph 7.1.1.18 of UL 489. Conversely, a UL Listed circuit breaker does not have to be marked with Line and if it successfully meets the reversefeed test requirements. Figure 3. s Showing Line and Markings, per UL 489 Line and Markings Cannot be Reverse-Fed:. When a UL Listed molded case circuit breaker and a molded case switch (not shown) are marked showing Line and, the power supply conductors must be connected to the end marked Line. These devices cannot be reverse-fed. Can be Reverse-Fed:. If Line and are not marked on the UL Listed. molded case circuit breaker, the power supply conductors. may be connected to either end. These devices are suitable. for reverse-feed applications. UL 1066 Low voltage AC and DC power circuit breakers used in enclosures As part of the standard test programs required by UL 1066. (referenced to ANSI/IEEET C37.50-1989) for low voltage power circuit breakers, tests are conducted that, when successfully. completed, demonstrate that the circuit breaker may be applied. in a reverse-feed configuration. These are mandatory tests that are done as part of the short-circuit current tests per Table 3 in Sequence II (Power-Operated with Dual Trip Device) of ANSI/IEEE C37.50-1989. As part. of this sequence, tests are to be performed with opposite. terminals energized. During these specified sequences of tests, the circuit breaker is energized in a reverse-feed configuration, and the satisfactory completion of these tests demonstrates their ability to be used in reverse-feed applications. Therefore, all low voltage power circuit breakers that are listed per UL 1066 may be reverse-fed. Can be Reverse-Fed:. Low voltage power circuit breakers that are listed. per UL 1066 may be reverse-fed. Special application considerations breakers with integral ground-fault protection Many of Eaton s UL Listed molded case and low voltage. power circuit breakers have design options and schemes that. allow for the detection and interruption of unwanted ground-fault currents. In these ground-fault protection schemes, the means. for ground-fault detection are either integral to the circuit breaker. or externally mounted. The ground-fault detection means commonly consist of current sensors and control logic circuitry that may be connected in various configurations as follows: 1. Separate current sensors that monitor each phase circuit... and the neutral circuit conductors, as shown in Figure 4 2. One current sensor that monitors all phases and the. neutral circuit conductors together (not shown) 3. One current sensor that monitors the ground. circuit conductor (not shown) Top Side of Power Source Neutral Conductor Neutral Current Sensor Electronic Trip Unit Three-Phase Current Sensors Control Logic ry Bottom Side of Ground-Fault Detection Means Figure 4. with Integral Ground-Fault Protection The interruption of ground-fault currents is done by the circuit. breaker opening all three-phase conductor circuits at the same time, in response to a trip signal from the ground-fault detection means. 3

Technical.Publication.PU01200001E Therefore,.whenever.an.unwanted.ground-fault.condition.exists,.a. UL.Listed.circuit.breaker.with.ground-fault.protection.will.detect.and. interrupt.the.ground-fault.current.flow. In.reverse-feed.applications,.while.the.primary.phase.currents.and. the.ground.currents.have.been.interrupted.with.the.opening.of.the. circuit.breaker,.voltage.at.the.circuit.breaker s.terminals.may.or.may. not.cause.damage.to.the.components.of.the.ground-fault.protection.system..if.components.in.the.detection.means.or.control.logic. circuitry.of.the.ground-fault.(or.the.phase.current).protection.system. may.be.damaged.by.reverse-feed.connections,.then.the.circuit. breaker.must.be.marked.accordingly..in.this.case,.where.the.circuit. breaker.with.ground-fault.protection.is.not.suitable.for.reverse-feed. applications,.the.circuit.breaker s.terminals.are.marked.with. Line. and..to.indicate.the.required.terminal.connection.points.for. the.power.supply.source.( Line ).and.the.load.( ). Conversely,.there.are.Eaton.circuit.breaker.design.configurations. where.the.components.in.the.ground-fault.(or.phase.current). protection.system.are.unaffected.by.reverse-feed.connections,. and.are.suitable.for.those.applications..these.circuit.breakers.are. not.marked.with. Line.and.,.to.indicate.that.they.are.suitable.for.reverse-feed.connections the.power.supply.source.may. be.connected.to.the.terminals.at.either.end.of.the.circuit.breaker. A.circuit.breaker.with.integral.ground-fault.protection.may.be. reverse.fed.if.it.is.not.marked.with. Line.and...The.UL. Listed.mark.that.is.applied.on.this.circuit.breaker.with.integral. ground-fault.protection.indicates.that.it.has.successfully.met.the. UL.test.requirements.for.reverse.feed.applications.. Cannot.be.Reverse-Fed:. When.a.UL.Listed.circuit.breaker.is.marked.showing. Line.and.,.the.power.supply.conductors.must.be.connected.to.the. end.marked. Line..These.devices.cannot.be.reverse-fed.. Can.be.Reverse-Fed:. If. Line.and..are.not.marked.on.the.UL.Listed.circuit. breaker,.the.power.supply.conductors.may.be.connected.to.either. end..these.devices.are.suitable.for.reverse-feed.applications. Molded case circuit breakers with external ground-fault/ earth leakage accessories There.are.ground-fault.current.detection.schemes.that.require.sensitivity.down.to.relatively.low.current.levels,.typically.as.low.as.30.mA.. These.products.are.called.ground-fault/earth.leakage.modules. sensor.and.logic.control.circuitry.all.located.inside.the.product. Depending.on.the.design.configuration.and.construction.of.these. earth.leakage.modules,.some.of.these.products.may.or.may.not.be. suitable.for.reverse-feed.applications..each.product.is.marked.with. a.label.containing.text.that.describes.their.suitability.for.reverse-feed. applications,.as.shown.in.figure 6.and.Figure 7. Figure 6. Earth Leakage Module Suitable for Reverse-Feed Applications Marking Showing Do Not Reverse Feed Marking Showing Where Must Be Connected Figure 7. Earth Leakage Modules Not Suitable for Reverse-Feed Applications Figure 5. Molded Case s with Earth Leakage Modules Earth Leakage Module Eaton s.molded.case.circuit.breakers.are.available.with.ul.listed. ground-fault.(earth.leakage).modules.that.are.typically.mounted. external.to.the. bottom.end.of.the.circuit.breaker,.as.shown.in. Figure 5..These.modules.are.self-contained.with.a.current. Note: The.only.acceptable.combination.of.circuit.breakers.and.earth. leakage.modules.that.should.be.used.in.reverse-feed.applications.is.where. BOTH.1).the.circuit.breaker.is.not.marked. Line.and.,.and.2).the. earth.leakage.module.is.not.marked. Line.and.,.and.not.marked. Do.not.reverse-feed.. Cannot.be.Reverse-Fed:. When.either.a.UL.Listed.circuit.breaker.is.marked.showing. Line.and.,.or.the.earth.leakage.module.is.marked.as. unsuitable.for.reverse-feed,.the.power.supply.conductors.must. be.connected.to.the. Line.end.of.the.circuit.breaker..These. devices.cannot.be.reverse-fed.. Can.be.Reverse-Fed:. If. Line.and..are.not.marked.on.the.UL.Listed. circuit.breaker,.and.the.earth.leakage.module.is.marked.as. suitable.for.reverse-feed,.the.power.supply.conductors.may. be.connected.to.either.end..these.devices.are.suitable.for. reverse-feed.applications. 4 eaton Corporation www.eaton.com

Technical Publication PU01200001E Miniature circuit breakers with integral ground-fault and arcing-fault protection Eaton s molded case circuit breakers are available with UL Listed ground-fault current protection levels that are able to detect and trip on ground-fault currents as low as 5 ma for personnel protection, and at 30 ma for sensitive electrical equipment. Eaton also has. circuit breakers that provide low-level 30 ma arcing-fault protection in residential applications. The constructions of these circuit breakers are typically in a single-pole or two-pole configuration, and with continuous ampere ratings of 15A through 100A. Due to their. relative small size and low continuous ampere ratings, these types. of molded case circuit breakers are commonly called miniature. circuit breakers. The 5 ma designs for personnel protection are known. as ground-fault circuit interrupters (GFCI) The 30 ma designs for equipment protection are known. as ground-fault equipment protectors (GFEP) The circuit breaker designs for arcing-fault protection are. known as arc-fault circuit interrupters (AFCI) While the overall performance of the circuit breaker is governed. by UL 489 for molded case circuit breakers, the specific 5 ma. personnel protection performance is per UL 943 ground-fault circuit interrupters, and the specific 30 ma performance for sensitive. electrical equipment is per UL 1053, ground-fault sensing and. relaying equipment. The AFCI performance requirements are. governed by UL 1699. For these AFCI, GFCI, and GFEP ground-fault protection designs, when the circuit breaker is closed, the control power for the groundfault control logic circuitry is typically connected to the side of the circuit breaker. Whenever a ground-fault condition occurs, the detection means and control logic circuit will operate and cause the circuit breaker s main current-carrying contacts to open without any intentional delay, and will interrupt the flow of the fault current. This instantaneous trip minimizes electrical shock hazards to personnel in GFCIs, and minimizes the flow of potentially damaging currents to sensitive electrical equipment in GFEP applications. In addition to the interruption of the ground-fault current, the detection means and control logic circuitry also rely on the main current-carrying contacts to open and disconnect the currents that flow though the detection and trip system. If power is applied to the Line terminals, and the load is connected to the terminals in a normal feed configuration, whenever the circuit breaker trips and the main current-carrying. contacts open, the ground-fault current is interrupted and control power is also disconnected from the detection means and control logic circuitry of the ground-fault system, as shown in Figure 8. Contacts Open Power Source Neutral Conductor When the circuit breaker trips and control power is disconnected from the control logic circuitry, no further current flows through the control logic circuitry to ground. On the other hand, if power is applied to the terminals, whenever the AFCI, GFCI, and GFEP circuit breaker trips and the. main current-carrying contacts open, the ground-fault current is. interrupted, but control power continues to be applied to the ground-. fault detection and control logic circuit of the ground-fault system, as shown in Figure 9. The presence of the control power will cause current to continually flow through the control logic circuitry. The effect of this continuous current may or may not degrade the. performance of the control logic circuitry over time. Contacts Open Voltage Still Present Bottom Side of Power Source Top Side of Ground Ground-Fault Detection Means and Control Logic ry Control Power Connection for Control Logic ry Figure 9. Miniature AFCI, GFCI, and GFEP Connected in Reverse-Feed Configuration Depending on the design configuration, the ground-fault detection means and control logic circuit of AFCI, GFCI, and GFEP miniature. circuit breakers may be affected by this reverse-feed application.. If the AFCI, GFCI, and GFEP circuit breaker is not able to be connected and applied in a reverse-feed configuration, the terminals. will be marked Line and. Cannot be Reverse-Fed:. When a UL Listed circuit breaker is marked showing Line and, the power supply conductors MUST be connected to the end marked Line. These devices cannot be reverse-fed. Can be Reverse-Fed:. If Line and are not marked on the UL Listed circuit breaker, the power supply conductors may be connected to either end. These devices are suitable to be reverse-feed applications. Ground-Fault Detection Means and Control Logic ry No Voltage Present Bottom Side of Ground Control Power Connection for Control Logic ry Figure 8. Miniature AFCI, GFCI, and GFEP Connected in Normal Feed Configuration 5

Technical Publication PU01200001E Summary Molded case circuit breakers, UL Listed per UL 489, have specific test and marking requirements to demonstrate that the circuit. breaker is suitable for reverse-feed applications. The capabilities of UL 1066 Listed low voltage power circuit. breakers for reverse-feed applications are verified as part of standard circuit breaker test sequences. If a circuit breaker and molded case switch are marked Line. and, it is not suitable for reverse-feed applications Only circuit breakers and molded case switches without Line. and markings are suitable for reverse-feed applications m WARNING For all types of Eaton s circuit breakers, do not connect the power source to circuit breaker terminals marked. For a list of Eaton s circuit breakers that are suitable for reverse-feed applications, visit www.eaton.com.. 6

Technical Publication PU01200001E 7

Technical Publication PU01200001E Eaton Corporation Electrical Sector 1111 Superior Ave. Cleveland, OH 44114 United States 877-ETN-CARE (877-386-2273) Eaton.com 2010 Eaton Corporation All Rights Reserved Printed in USA Publication No. PU01200001E / Z9837 May 2010 PowerChain Management is a registered trademark of Eaton Corporation. All other trademarks are property of their respective owners.