In Row Cooling Options for High Density IT Applications

Similar documents
CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

Data Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.

Elements of Energy Efficiency in Data Centre Cooling Architecture

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

APC APPLICATION NOTE #112

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

- White Paper - Data Centre Cooling. Best Practice

GREEN FIELD DATA CENTER DESIGN WATER COOLING FOR MAXIMUM EFFICIENCY. Shlomo Novotny, Vice President and Chief Technology Officer, Vette Corp.

Blade Server & Data Room Cooling Specialists

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS

Five Strategies for Cutting Data Center Energy Costs Through Enhanced Cooling Efficiency

2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms

The Different Types of Air Conditioning Equipment for IT Environments

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

STULZ Water-Side Economizer Solutions

Element D Services Heating, Ventilating, and Air Conditioning

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

EHDC. Cooling system for Data Center and server cabinets.

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

State of the Art Energy Efficient Data Centre Air Conditioning

Data Centers WHAT S ONTHEHORIZON FOR NR HVAC IN TITLE ? SLIDE 1

The New Data Center Cooling Paradigm The Tiered Approach

AIRAH Presentation April 30 th 2014

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

Raised Floor Data Centers Prepared for the Future

IT White Paper MANAGING EXTREME HEAT: COOLING STRATEGIES FOR HIGH-DENSITY SYSTEMS

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001

Critical Infrastructure for the World s Leading Data Centers

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

White Paper. Data Center Containment Cooling Strategies. Abstract WHITE PAPER EC9001. Geist Updated August 2010

APC APPLICATION NOTE #92

News in Data Center Cooling

National Grid Your Partner in Energy Solutions

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

How To Improve Energy Efficiency Through Raising Inlet Temperatures

Unified Physical Infrastructure (UPI) Strategies for Thermal Management

Agenda. Who we are What we do How we serve the BPO Industry

Reference Guide: SmartDesign Approach: Common Data Center Challenges:

Rittal White Paper 507: Understanding Data Center Cooling Energy Usage & Reduction Methods By: Daniel Kennedy

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Best Practices for Wire-free Environmental Monitoring in the Data Center

Data Center Components Overview

Best Practices in HVAC Design/Retrofit

Liebert : The Right Cooling For IT Environments. Precision Cooling For Business-Critical Continuity

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: Uptime Racks:

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

University of St Andrews. Energy Efficient Data Centre Cooling

Legacy Data Centres Upgrading the cooling capabilities What are the options?

Direct Fresh Air Free Cooling of Data Centres

Supporting Cisco Switches In Hot Aisle/Cold Aisle Data Centers

Benefits of. Air Flow Management. Data Center

Unified Physical Infrastructure SM (UPI) Strategies for Smart Data Centers

White Paper Rack climate control in data centres

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

Cooling Audit for Identifying Potential Cooling Problems in Data Centers

Energy-efficient & scalable data center infrastructure design

LEVEL 3 DATA CENTER ASSESSMENT

JAWAHARLAL NEHRU UNIVERSITY

Improving Data Center Efficiency with Rack or Row Cooling Devices:

Technical Systems. Helen Bedford

European Code of Conduct for Data Centre. Presentation of the Awards 2016

Data Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM

Airflow Simulation Solves Data Centre Cooling Problem

LIEBERT CORPORATION Air Products. Model Number Reference Guide. Revision: April 2004

Improving Data Center Energy Efficiency Through Environmental Optimization

york air-conditioning products Residential & VRF News 2015

HVAC Systems: Overview

Analysis of data centre cooling energy efficiency

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

Thermal Monitoring Best Practices Benefits gained through proper deployment and utilizing sensors that work with evolving monitoring systems

Defining Quality. Building Comfort. Precision. Air Conditioning

Data Center Energy Profiler Questions Checklist

Reducing Data Center Energy Consumption

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

Power and Cooling for Ultra-High Density Racks and Blade Servers

Tech Byte 27: Small Computer Room and IT Closet Cooling

Economizer Fundamentals: Smart Approaches to Energy-Efficient Free-Cooling for Data Centers

High Density Data Centers Fraught with Peril. Richard A. Greco, Principal EYP Mission Critical Facilities, Inc.

Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009

Paul Oliver Sales Director. Paul Oliver, Airedale Tom Absalom, JCA

Data Center Cooling Critical Facility & Infrastructure Optimization. Presented by. Greg Stover SVP NER Data Corporation

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings

CRAC Precision climate control units for data centres

Energy Efficient Cooling Solutions for Data Centers

Ten Steps to Solving Cooling Problems Caused by High- Density Server Deployment

Environmental Data Center Management and Monitoring

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Choosing Close-Coupled IT Cooling Solutions

EXAMPLE OF A DATA CENTRE BUILD

5 Reasons. Environment Sensors are used in all Modern Data Centers

IPSIP M series-m Modular Data Center

Innovent LASER Packaged Fresh Air Conditioning Units

Blade Servers and Beyond: Adaptive Cooling for the Next Generation of IT Systems. A White Paper from the Experts in Business-Critical Continuity

Green Data Centre Design

Transcription:

In Row Cooling Options for High Density IT Applications By Ramzi Y. Namek, PE, LEED AP, BD+C; Director of Engineering

1 Users wishing to deploy high density IT racks have several In Row Cooling solutions from which to select. In Rows come in multiple configurations adaptable to various space and aisle constraints. They can be mounted in the ceiling, over the racks, within the racks, or in the aisle. The two most common cooling media used inside the units are either refrigerant (R134a) or water; the user has a choice to use either type based on preference and comfort level. Overhead units are meant to handle sensible cooling only and hence no condensate is typically generated in the process. In fact, the internal controls monitor dew point closely and maintain refrigerant and coil temperatures above room dew point. Vertical aisle In Rows such as the RP by APC do have humidity control. Liebert makes a self contained unit that operates either on chilled water or glycol. The message is that these units come in various flavors and colors to satisfy the needs for your high density cooling deployment. In this whitepaper, we will review some common In Row coolers available from vendors that have been manufacturing this type of solution for the past 5 years. We will compare and evaluate several technical and operational parameters and rank them in terms of a three-tiered favorability matrix. While this list is not inclusive of every In Row cooler type available in the market, it provides the user a starting point from which to gather intelligent information about various unit makes and models. Refrigerant Based In Row Coolers A. Rack Overhead Liebert XDV An XDV system is a modular cooling solution that mounts directly on the top of the racks or alternatively, suspended above the racks. Each unit connects to a main supply and return header utilizing either rigid or flexible piping with quick connect fittings. One option is to stack the XDV s and install blanking panels between the openings, although this would add complexity and cost to the install. Rack Mounted XDV Sensible Cooling Only Available in 8.8 kw and 10 kw modules. Units mount on top of Racks. Planning for additional units is relatively easy. Connects via flexible piping with quick connect fittings

2 Will need coordination with overhead IT and power cabling Dual A-B Power cords for increased uptime. Two fans on each unit add to reliability. Dependent on the reliability of the XDC unit. Minimal maintenance required: 1. Cooling fins should be kept clean 2. Circulating fans are easily accessible from the front and require no lubrication. Involves copper headers and quick connects with valves, controls and wiring. Requires an XDC unit. Dimensions Hx Wx D 14"x 23"x 40" $$$ B. Row Mounted Liebert XDH An XDH system is a modular cooling solution that mounts in the row between racks or at the end of a row. Each unit connects to a main supply and return header utilizing either rigid or flexible piping with quick connects. Row Mounted XDH Sensible Cooling Only Available in 22 kw and 30 kw modules. Units are floor mounted in between racks or at the end of a row. Will require planning day-one for location of units. Connects via flexible piping with quick connect fittings. Floor mounted is easier to coordinate Dual A-B Power cords for increased uptime. Two pumped refrigerant circuits. Multiple fans for load shedding. LED sensors indicate status. Dependent on the reliability of the XDC unit.

3 Floor mounted units are easier to access for maintenance.. Minimal maintenance required: 1. cooling fins should be kept clean 2. circulating fans are easily accessible from the front and require no lubrication Involves copper headers and quick connects with valves, controls and wiring. Requires an XDC unit. $$$$ Dimensions Hx Wx D 78" x 12" x 42" C. Aisle Overhead Liebert XDO An XDO system is a modular cooling solution that mounts over the cold aisle with a Unistrut system. The unit pulls hot air from the two opposite inlets and a fan discharges the cold air down into the cold aisle. Each unit connects to a main supply and return header utilizing either rigid or flexible piping with quick connects. The user should note that the cooling value of this unit should really be analyzed as it could be disproportionally shared by two opposing racks in the cold isle. Aisle Overhead Mounted Sensible Cooling Only XDO Available in 17.2 kw and 20 kw modules. Units mount over cold aisles. Planning for additional units is relatively easy. Connects via flexible piping with quick connect fittings Will need coordination with overhead IT and power cabling. Mounting above the cold aisle May require additional lighting. Dual A-B Power cords for increased uptime. Dependent on the reliability of the XDC unit. Minimal maintenance required: 1. Cooling fins should be kept clean 2. Circulating fan is easily

4 accessible from the bottom of the module and requires no lubrication Involves copper headers and quick connects with valves, controls and wiring. Requires an XDC unit. $$$$ Dimensions Hx Wx D 22.5 x 72 x 24 D. Aisle Overhead APC OA The OA system is a modular cooling solution that mounts over the hot aisle utilizing a Unistrut system or APC s OA mounting frame. The unit pulls air from the hot aisle via two fans and discharges the cold air vertically where it is eventually drawn back into the front of the racks. Each unit connects to a main supply and return header utilizing rigid or flexible piping with quick connects. The headers connect to the RDU cooling distribution unit capable of providing 160 kw of cooling. Again, the user is reminded that the cooling value of this unit should be analyzed as it will be removing heat from the common hot aisle. The rank was elevated to Medium as the kw is slightly higher for this unit. Aisle Overhead Mounted OA Sensible Cooling Only Up to 27 kw (5 to 14 kw/rack densities) Units mount over hot aisles. Planning for additional units is relatively easy. Connects via flexible piping with quick connect fittings Will need coordination with overhead IT and power cabling. Mounting above the hot aisle may require additional lighting. Dual A-B Power cords for increased uptime. Dependent on the reliability of the RDU unit.

5 Minimal maintenance required: 1. Cooling fins should be kept clean 2. Circulating fan is easily accessible from the bottom of the module and requires no lubrication Involves copper headers and quick connects with valves, controls and wiring. Requires an RDU unit. Dimensions Hx Wx D 13.9 x 51.7 x 23.5 $$$$ E. Rear Door Heat Exchangers Liebert XDR An XDR system is a fixed cooling solution that mounts directly to the rear of the IT rack. Each unit connects to a main supply and return header utilizing rigid or flexible piping with quick connects. Door Mounted XDR Sensible Cooling Only 20.5 kw Units are passive fanless heat exchangers that replace the rear door of the IT rack. Relies on server fans to provide airflow through the unit. Connects via hard and flexible piping. Once installed however, the cooling capacity is fixed and can t be scaled down. Replaces IT rack rear door. The unit is passive, no moving parts to fail other than the quick coupling which is installed on all the XD class units. No moving parts to maintain. Scheduled cleaning of the coil fins. Involves copper headers and quick connects with valves, controls and wiring. Requires an XDC unit. $$$

6 Dimensions Hx Wx D 78.4 x 23.5 x 5.9 Only compatible with a 24 x 42 U Rack Water Based In Row Coolers A. Rack Mounted APC RC & RP 600 mm (24 ) The RP/RC600 system is a modular cooling solution that mounts in the row between racks. Each unit ties to a main supply and return chilled water header through rigid and flexible piping. Row Mounted RP600, RC600 Cooling w/ Option For Reheat and Humidity Control (RP Only) & Condensate Management (both units) Nominal 43 kw. Can go up to 70 kw. Units are floor mounted in between racks. Will require planning day-one for location of units. Connects via flexible piping. Floor mounted is easier to coordinate Dual A-B Power only on RC600. Multiple fans for variable load control. LED sensors indicate status. Floor mounted is easier to maintain. Minimal maintenance required: 1. Cooling fins should be kept clean 2. Circulating fans are easily accessible and require no lubrication Involves copper headers and quick connects with valves, controls and wiring. Dimensions Hx Wx D 78" x 24" x 42" $$$$$

7 B. Row Mounted APC RC300 An RC system is a modular cooling solution that mounts in the row between racks. Each unit ties to a main supply and return chilled water header through rigid or flexible piping. Row Mounted RC300 Sensible Cooling w/ Option For Condensate Management Nominal 18.2 kw. Can go up to 30 kw. Units are floor mounted in between racks. Will require planning day-one for location of units. Connects via flexible piping. Floor mounted is easier to coordinate Dual A-B Power cords for increased uptime. Multiple fans for variable load control. LED sensors indicate status. Floor mounted is easier to maintain. Minimal maintenance required: 1. Cooling fins should be kept clean 2. Circulating fans are easily accessible and require no lubrication Involves copper headers and quick connects with valves, controls and wiring. Dimensions Hx Wx D 78" x 12" x 42" $$$$

8 C. Rear Door Heat Exchangers (RDHx) Coolcentric Vette The system is a fixed cooling solution that mounts directly to the rear of the IT rack. Each unit ties to a main supply and return chilled water header through rigid and flexible piping with quick connects. RDHx Coolcentric Sensible Cooling Only 16 kw up to 35kW Units are passive fanless heat exchangers mounted on the rear door of the IT rack. Connects via hard and flexible piping. Once installed however, the cooling is cooling capacity is fixed and can t be scaled down. Door mounted. The unit is passive, no moving parts to fail No moving parts to maintain. Scheduled cleaning of the coil fins. Dimensions Hx Wx D Involves copper headers and quick connects with valves, controls and wiring. Requires a cooling distribution unit CDU. Compatible with a 42U x 24 rack but can be modified for a 30 wide rack. Standalone In Row Coolers A. Liebert CRV DX Standalone Cooling Unit A Liebert CRV is a standalone unit that connects directly to an outdoor condensing unit, drycooler, or chilled water. As such, it eliminates the need for the middle cooling distribution unit. It has state of the art scalable cooling and control capabilities and may be specified with integral humidification and reheat.

9 Liebert Air Cooled CRV Unit Full Cooling Capability using DX, Glycol, or Chilled Water Available in 20 kw and 35 kw Air Cooled modules The units are compact and fully contained with front and rear access. Digital Scroll compressors and variable speed fans within the unit enable variable cooling capacity from 20-100%. Each unit is piped separately to a condenser/ drycooler/cooling tower or chilled water source. Unit sits on the floor but requires a more extensive installation. Multiple fans and Compressors with full monitoring capability. The unit is fully contained with scroll compressors and EC fans (non chilled water unit). It may also be specified with options for built in reheat, humidification, and a condensate pump. Therefore the unit will have more components to maintain. This unit is piped similar to a standalone DX/Glycol/Chilled water CRAC unit. Dimensions Hx Wx D 78.84 x 23.6 x 43.3 Conclusion There is no lack of choice when it comes to selecting an In Row cooling solution for high density applications. We have presented several products with a ranking matrix that can clarify the technical and operational impacts when selecting amongst the many brand names. While the list of products was limited to three manufacturers: Liebert, APC, and Coolcentric, additional products from Huntair, Stulz and Motiveair are being introduced and will most likely go through the same process to gain customer confidence and truly compete in the high density market. In TSS database of previous and ongoing projects, we have designed, installed, commissioned and maintained almost all the types mentioned in this paper. TSS can help you in your next high

10 density installation project from the conceptual selection process through design, construction, and facility maintenance of the completed project. About the Author Ramzi Y. Namek, PE, LEED AP BD+C; Director of Engineering, Total Site Solutions Mr. Namek is located out of the headquarter office of TSS in Columbia, Maryland and has over 17 years of experience in both Design and Project Management of mechanical systems for mission-critical, commercial, and government projects. He is skilled in HVAC, plumbing, and fire protection design, construction management, engineering economics, as well as energy analysis. With over ten publications in various leading industry journals, his current areas of interest are in data center energy efficiency, the cloud computing environment, and the dynamics of change in the data center business model. Mr. Namek was awarded his B.S. Degree in Mechanical Engineering from American University of Beirut and his M.S. Degree in Engineering Management from Virginia Tech. He is a board member in the ASHRAE National Capital Chapter.